TY - JOUR A1 - Förstl, Nikolas A1 - Süß, Franz A1 - Englert, Carsten A1 - Dendorfer, Sebastian T1 - Design of a reverse shoulder implant to measure shoulder stiffness during implant component positioning JF - Medical Engineering & Physics N2 - To avoid dislocation of the shoulder joint after reverse total shoulder arthroplasty, it is important to achieve sufficient shoulder stability when placing the implant components during surgery. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this research was to develop a temporary reverse shoulder implant prototype that would allow intraoperative measurement of shoulder stiffness while varying the position of the implant components. Joint angle and torque measurement techniques were developed to determine shoulder stiffness. Hall sensors were used to measure the joint angles by converting the magnetic flux densities into angles. The accuracy of the joint angle measurements was tested using a test bench. Torques were determined by using thin-film pressure sensors. Various mechanical mechanisms for variable positioning of the implant components were integrated into the prototype. The results of the joint angle measurements showed measurement errors of less than 5° in a deflection range of ±15° adduction/abduction combined with ±45° flexion/extension. The proposed design provides a first approach for intra-operative assessment of shoulder stiffness. The findings can be used as a technological basis for further developments. Y1 - 2023 U6 - https://doi.org/10.1016/j.medengphy.2023.104059 N1 - Corresponding author: Sebstian Dendorfer VL - 121 PB - Elsevier ET - Journal Pre-proof ER - TY - JOUR A1 - Mikhaeil, Makram A1 - Nowak, Sebastian A1 - Palomba, Valeria A1 - Frazzica, Andrea A1 - Gaderer, Matthias A1 - Dawoud, Belal T1 - Experimental and analytical investigation of applying an asymmetric plate heat exchanger as an evaporator in a thermally driven adsorption appliance JF - Applied Thermal Engineering N2 - This communication presents an experimental and analytical study on the evaporation mechanism in a closed-structured asymmetric plate heat exchanger (PHE) employed as a stagnant water evaporator for the application in an adsorption heat transformation appliance. To this aim, an experimental unit is constructed, which comprises two identical PHEs, one acting as an vaporator/condenser and the second, as an adsorber/desorber. Two endoscopes are mounted inside the investigated evaporator to visualize the evaporation mechanism when performing adsorption-evaporation processes under different boundary conditions. It turned out that the evaporation mechanism is a partially covered, thin film evaporation. A heat transfer analysis is performed to evaluate the heat transfer coefficient of the thin film evaporation () inside the investigated evaporator, resulting in -values between 1330 and 160 [W∙m−2∙K−1] over the investigated adsorption-evaporation time. Correlating the obtained () to the film thickness and the wetted area results in -values between 0.34 and 0.78 [mm] and wetted to total area ratios of 0.78 to 0.16. Besides, an analytical model has been developed and introduced to correlate the overall evaporator heat transfer coefficient with the adsorption potential and the time rate of change of the water uptake. KW - Adsorption-evaporation KW - Evaporator KW - Plate heat exchanger KW - Thin film evaporation Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-61115 N1 - Corresponding author: Belal Dawoud IS - 228 PB - Elsevier ER - TY - JOUR A1 - Troidl, Kilian A1 - Schroll-Decker, Irmgard T1 - Wie theoriebasiert sind Forschungsbeiträge zur Bildungsbeteiligung? Eine Qualitative Inhaltsanalyse ausgewählter Fachzeitschriften der Erwachsenen- und Weiterbildungsforschung JF - Zeitschrift für Weiterbildungsforschung N2 - In der Vergangenheit wurde beklagt, dass in der empirischen Forschung zur Bildungsbeteiligung Erwachsener selten eine Integration von Theorie und Empirie erfolge und die mangelnde empirische Prüfung eine theoretische Weiterentwicklung des Forschungsfeldes erschwere. Mittels einer Qualitativen Inhaltsanalyse von Beiträgen ausgewählter Fachzeitschriften der Erwachsenen‑/Weiterbildungsforschung wurde versucht, die Aktualität dieser Feststellung empirisch zu überprüfen. Dazu wurden 38 empirische Forschungsbeiträge zur Bildungsbeteiligung der Jahrgänge 2018 bis 2020 von neun Fachzeitschriften mit Peer-Review untersucht. Die Einschätzung der Beiträge erfolgte hinsichtlich des Grades der Theorieeinbindung. Die Ergebnisse der Analyse zeigen ein gemischtes Bild: neun Beiträge (24 %) binden keine Theorie in den Forschungsprozess ein, ein Beitrag (3 %) zitiert Theorie lediglich, ohne sie weiter einzubinden. Am häufigsten ist eine Einbindung zum theoriegeleiteten Vorgehen (16 Beiträge, 42 %). Eine tiefergehende Theorieanwendung findet sich in sechs Beiträgen (16 %). Eine theorieprüfende oder -bildende Einbindung liegt mit je drei Beiträgen (je 8 %) seltener vor. Die rezipierten Theorien sind vielfältig: es werden 20 verschiedene Theorieansätze festgestellt. Den Forderungen nach einer verstärkten Einbindung von Theorie in den Forschungsprozess kann somit weiterhin Gültigkeit attestiert werden: ein substanzieller Teil der Beiträge berichtet keine Theorieeinbindung, eine empirische Prüfung oder Weiterentwicklung findet relativ selten statt. N2 - Regarding empirical research on participation in adult education, it has been criticized that only rarely has there been an integration of theoretical and empirical approaches and that empirical testing was lacking. This, it has been stated, was an impediment to further developing the research field. To empirically check if this is still the case, a qualitative content analysis of selected journals in the field of adult and continuing education was carried out. 38 peer-reviewed articles, published in professional journals between 2018 and 2020, which presented empirical research on participation in adult education were examined. The main goal of this study was to assess the extent to which theory is used in these articles along a continuum of theory use. The result of the analysis gave a mixed picture. Nine contributions (24%) show no reference to theory at all, one contribution (3%) merely cites theoretical work without making further use of it. Most frequently, theory is reported to inform the empirical research (16 contributions, 42%); six contributions (16%) further apply theory. Only three contributions (8%) report either theory testing or building. The theories used vary: 20 different theoretical approaches were observed. A thorough integration of theory into the research process still seems to be lacking: Most articles report no or only limited use of theory. Empirical testing or further development of theory only takes place in a small portion of the studies analyzed. T2 - The use of theory in research on participation in adult education: A qualitative content analysis of key adult and continuing education journals KW - Erwachsenenbildung KW - Weiterbildung KW - Wissenschaftliche Zeitschrift KW - Qualitative Inhaltsanalyse KW - Bildungsbeteiligung KW - Adult learning participation KW - Research on participation KW - Theory use KW - Journals KW - Qualitative content analysis Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-55460 N1 - Corresponding author: Irmgard Schroll-Decker VL - 45 PB - Springer Nature ER - TY - JOUR A1 - Scharf, Anna A1 - Haug, Sonja A1 - Ritthaler, Markus A1 - Raptis, Georgios T1 - Chancen und Herausforderungen der Digitalisierung bei der Rehabilitation – Ergebnisse einer Befragung von Rehabilitationseinrichtungen JF - Die Rehabilitation: Zeitschrift für Praxis und Forschung in der Rehabilitation N2 - Ziel der Studie: Ziel der Studie ist die Messung des Stands der Digitalisierung und die mit einer Anbindung an die Telematikinfrastruktur verbundenen Chancen und Herausforderungen für Rehabilitationseinrichtungen. Methodik: Teilstandardisierte Online-Befragung bei Trägern von Rehabilitationseinrichtungen in Bayern (n=33). Der Fragebogen mit 36 Fragen beinhaltet eine leicht veränderte Skala auf Basis des „Electronic Medical Record Adoption Model (EMRAM)“. Ergebnisse: Der Digitalisierungsgrad wurde in 70 Prozent der Rehabilitationseinrichtungen mit Stufe 0 angegeben (Stufenmodell bis 7). Die Übermittlung patientenbezogener Daten (Eingang und Ausgang) erfolgt häufig analog, wohingegen die Verarbeitung innerhalb der Einrichtung in vielen Fällen bereits überwiegend digital ist. Beim Anschluss an die Telematikinfrastruktur wird hoher Aufwand bei der Installation, aber auch der Schulung des Personals und der Anpassung der Arbeitsorganisation gesehen. Schlussfolgerung: Durch Änderung der gesetzlich-finanziellen Lage in Deutschland eröffnen sich für Rehabilitationseinrichtungen neue Möglichkeiten einer verstärkten Digitalisierung. Hürden hängen mit Anforderungen an IT-Sicherheit, Schulung des Personals und sowie dem ebenfalls geringen Digitalisierungsstand bei Krankenhäusern und Ärzt*innen sowie Patient*innen zusammen, die eine digitale Datenübermittlung erschweren. T2 - Opportunities and Challenges of Digitalization in Rehabilitation: Results of a Survey of Rehabilitation Facilities KW - Patientenbezogene Daten KW - Digitalisierungsgrad KW - Telematikinfrastruktur KW - IT-Management Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-64726 N1 - Corresponding author: Sonja Haug VL - 62 IS - 5 SP - 299 EP - 307 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Kloiber, Jessica A1 - Schultheiß, Ulrich A1 - Sotelo, Lamborghini A1 - Sarau, George A1 - Christiansen, Silke A1 - Gavras, Sarkis A1 - Hort, Norbert A1 - Hornberger, Helga T1 - Corrosion behaviour of electropolished magnesium materials JF - Materials Today Communications N2 - Although magnesium and its alloys are promising candidates as biodegradable implant materials, the tendency for localized corrosion mechanism in physiological environment limit their biomedical application. Electropolishing is an attractive strategy for improving the corrosion behaviour of metals, but it is still largely unexplored in magnesium materials. In this study, the characterization of electropolished surfaces of AM50 and pure magnesium was performed, focussing on their in vitro degradation behaviour in cell medium. Corrosion rates were evaluated using potentiodynamic polarisation. The surface morphology before and after the onset of corrosion was investigated by scanning electron microscopy and confocal laser scanning microscopy. The presented electropolishing process led to improved surface performances, observable by significantly lower corrosion rates (0.08 mm·year-1 in Dulbecco's modified Eagle's medium), lower arithmetical mean height (0.05 µm), lower water contact angle (25-35°) and lower micro hardness (35-50 HV 0.1) compared to mechanically and chemically treated surfaces. MgO/Mg(OH)2 could be detected on electropolished surfaces. The localized corrosion mode could be reduced, but not entirely prevented. Electropolishing shows great potential as post-treatment of magnesium-based components, but detailed tests of the long-term corrosion behaviour are an important area of future research. KW - biomedical application KW - corrosion behaviour KW - electropolishing KW - magnesium alloy KW - pure magnesium KW - surface characterization Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-68254 N1 - Corresponding author: Helga Hornberger PB - Elsevier ET - Journal Pre-proof ER - TY - JOUR A1 - Tauwald, Sandra Melina A1 - Erzinger, Florian A1 - Quadrio, Maurizio A1 - Rütten, Markus A1 - Stemmer, Christian A1 - Krenkel, Lars T1 - Tomo-PIV in a patient-specific model of human nasal cavities: a methodological approach JF - Measurement Science and Technology N2 - The human nose serves as the primary gateway for air entering the respiratory system and plays a vital role in breathing. Nasal breathing difficulties are a significant health concern, leading to substantial healthcare costs for patients. Understanding nasal airflow dynamics is crucial for comprehending respiratory mechanisms. This article presents a detailed study using tomo-Particle Image Velocimetry (PIV) to investigate nasal airflow dynamics while addressing its accuracy. Embedded in the OpenNose project, the work described aims to provide a validation basis for different numerical approaches to upper airway flow. The study includes the manufacturing of a transparent silicone model based on a clinical CT scan, refractive index matching to minimize optical distortions, and precise flow rate adjustments based on physiological breathing cycles. This method allows for spatial high-resolution investigations in different regions of interest within the nasopharynx during various phases of the breathing cycle. The results demonstrate the accuracy of the investigations, enabling detailed analysis of flow structures and gradients. This spatial high-resolution tomo-PIV approach provides valuable insights into the complex flow phenomena occurring during the physiological breathing cycle in the nasopharynx. The study's findings contribute to advancements in non-free-of-sight experimental flow investigation of complex cavities under nearly realistic conditions. Furthermore, reliable and accurate experimental data is crucial for properly validating numerical approaches that compute this patient-specific flow for clinical purposes. Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-70393 N1 - Corresponding author: Sandra Melina Tauwald VL - 35 IS - 5 PB - IOP Publishing ER - TY - JOUR A1 - Käss, Sebastian A1 - Strahringer, Susanne A1 - Westner, Markus T1 - Practitioners’ Perceptions on the Adoption of Low Code Development Platforms JF - IEEE Access N2 - Organizations are under increasing pressure to develop applications within budget and time at high quality. Therefore, multiple organizations adopt Low Code Development Platforms (LCDP) to develop applications faster and cheaper compared to traditional application development. However, current research on LCDP adoption lacks empirical grounding as well as a deeper understanding of the importance of adoption drivers and inhibitors. We conducted semi-structured interviews and a Delphi study with seventeen experts to address these gaps. As a result, we identified twelve drivers and nineteen inhibitors for adopting LCDPs. We show that the experts have a consensus on the most and the least important drivers and inhibitors for LCDP adoption. Yet, the ranking of the drivers and inhibitors between the most and least important is highly context dependent. For some drivers and inhibitors, the experts’ ranking is similar to academic literature, whereas, for others, it differs. In conclusion, the study at hand empirically validates drivers and inhibitors for LCDP adoption, adds six new drivers and six new inhibitors to the body of knowledge, and analyses the importance of these factors. KW - Low code KW - Delphi Study KW - Software Development KW - Inhibitor KW - Driver Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-59170 SN - 2169-3536 N1 - Corresponding author: Markus Westner PB - IEEE ER - TY - JOUR A1 - Haug, Sonja A1 - Schnell, Rainer A1 - Raptis, Georgios A1 - Dotter, Caroline A1 - Weber, Karsten T1 - Wissen und Einstellung zur Speicherung und Nutzung von Gesundheitsdaten: Ergebnisse einer Bevölkerungsbefragung JF - Zeitschrift für Evidenz, Fortbildung und Qualität im Gesundheitswesen N2 - Hintergrund/Zielsetzung Der Beitrag befasst sich mit dem Wissenstand und der Einstellung der Bevölkerung. Betrachtet werden die Übermittlung und Verfügbarkeit von Gesundheitsdaten, Gesundheitsregister, die elektronische Patientenakte, Einwilligungsverfahren für die Übermittlung von Daten und der Zugriff auf Gesundheitsdaten zu Forschungszwecken. Methoden Die Studie basiert auf einer computergestützten Telefonbefragung (Dual-Frame) bei einer Zufallsstichprobe der Bevölkerung in Deutschland im Zeitraum 01.-27.06.2022 (n = 1.308). Ergebnisse Der Wissensstand zur Übermittlung von Gesundheitsdaten an Krankenkassen ist hoch, wohingegen das Vorhandensein zentraler Sterbe-, Impf- und Gesundheitsregister sowie der Zugriff auf Gesundheitsdaten durch behandelnde Ärztinnen und Ärzte überschätzt werden. Die Akzeptanz medizinischer Register ist sehr hoch. Die elektronische Patientenakte ist bei der Hälfte der Bevölkerung unbekannt, die Nutzungsbereitschaft ist eher gering ausgeprägt; bei der Übertragung von Daten wird eine Zustimmungsoption bevorzugt, und über achtzig Prozent würden die Daten der elektronischen Patientenakte zur Forschung freigeben. Drei Viertel würden ihre Gesundheitsdaten allgemein zur Forschung freigeben, insbesondere an Universitäten in Deutschland, wobei meist Anonymität Bedingung ist. Die Bereitschaft zur Datenfreigabe steigt mit der Höhe des Vertrauens in die Presse sowie in Universitäten und Hochschulen, und sie sinkt, wenn ein Datenleck als schwerwiegend erachtet wird. Diskussion und Schlussfolgerung In Deutschland besteht, wie in anderen europäischen Ländern, eine große Bereitschaft zur Freigabe von Gesundheitsdaten zu Forschungszwecken. Dagegen ist der Wunsch zur Nutzung der elektronischen Patientenakte eher gering. Ebenso niedrig ist die Akzeptanz einer Widerspruchsoption, die jedoch als Voraussetzung für eine erfolgreiche Einführung einer elektronischen Patientenakte gilt. Vertrauen in die Forschung und staatliche Stellen, die Gesundheitsdaten verarbeiten, sind zentrale Faktoren. T2 - Knowledge and attitudes towards sharing of health data: Results of a population survey Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-67461 SN - 1865-9217 N1 - Corresponding author: Sonja Haug N1 - Fragebogen u.d.T.: "Projekt: Privacy und Willingness to share von Gesundheitsdaten (PWG)"; auf dem Publikationsserver unter https://opus4.kobv.de/opus4-oth-regensburg/frontdoor/index/index/docId/6057 abgelegt. N1 - Preprint unter: https://opus4.kobv.de/opus4-oth-regensburg/frontdoor/index/index/docId/6144 SP - 50 EP - 58 PB - Elsevier ER - TY - JOUR A1 - Loo, Xuyan A1 - Nagaraju, Bhavana A1 - Pathivada, Sai A1 - Bartsch, Alexander A1 - Schratzenstaller, Thomas A1 - Sattler, Robert A1 - Monkman, Gareth J. T1 - Electrical properties of bisphenol-A-free magnetoactive borosilicate polymers JF - AIP Advances N2 - The recent REACH regulations require the elimination of bisphenol-A and titanium dioxide from commercially available boron-based polymers. This has led to changes in some of the mechanical characteristics, which strongly influence the properties of magnetoactive borosilicate polymers. This work delivers results on the electrical properties and discusses some implications for future research using bisphenol-A and titanium-dioxide-free substitutes. KW - Electrical components KW - Electrical properties and parameters KW - Dielectric properties KW - Electrical resistivity KW - Magnetic materials KW - Viscoelasticity KW - Polymers KW - Non Newtonian fluids KW - Magnetic fluids Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-72936 SN - 2158-3226 N1 - Corresponding author der OTH Regensburg: Gareth J. Monkman VL - 14 IS - 5 PB - AIP Publishing ER - TY - JOUR A1 - Mendel, Robert A1 - Rauber, David A1 - Souza Jr., Luis Antonio de A1 - Papa, João Paulo A1 - Palm, Christoph T1 - Error-Correcting Mean-Teacher: Corrections instead of consistency-targets applied to semi-supervised medical image segmentation JF - Computers in Biology and Medicine N2 - Semantic segmentation is an essential task in medical imaging research. Many powerful deep-learning-based approaches can be employed for this problem, but they are dependent on the availability of an expansive labeled dataset. In this work, we augment such supervised segmentation models to be suitable for learning from unlabeled data. Our semi-supervised approach, termed Error-Correcting Mean-Teacher, uses an exponential moving average model like the original Mean Teacher but introduces our new paradigm of error correction. The original segmentation network is augmented to handle this secondary correction task. Both tasks build upon the core feature extraction layers of the model. For the correction task, features detected in the input image are fused with features detected in the predicted segmentation and further processed with task-specific decoder layers. The combination of image and segmentation features allows the model to correct present mistakes in the given input pair. The correction task is trained jointly on the labeled data. On unlabeled data, the exponential moving average of the original network corrects the student’s prediction. The combined outputs of the students’ prediction with the teachers’ correction form the basis for the semi-supervised update. We evaluate our method with the 2017 and 2018 Robotic Scene Segmentation data, the ISIC 2017 and the BraTS 2020 Challenges, a proprietary Endoscopic Submucosal Dissection dataset, Cityscapes, and Pascal VOC 2012. Additionally, we analyze the impact of the individual components and examine the behavior when the amount of labeled data varies, with experiments performed on two distinct segmentation architectures. Our method shows improvements in terms of the mean Intersection over Union over the supervised baseline and competing methods. Code is available at https://github.com/CloneRob/ECMT. KW - Semi-supervised Segmentation KW - Mean-Teacher KW - Pseudo-labels KW - Medical Imaging Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-57790 SN - 0010-4825 VL - 154 IS - March PB - Elsevier ER - TY - JOUR A1 - Auer, Simon A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics JF - Technology and Health Care N2 - BACKGROUND: This study presents a comprehensive comparison between a marker-based motion capture system (MMC) and a video-based motion capture system (VMC) in the context of kinematic analysis using musculoskeletal models. OBJECTIVE: Focusing on joint angles, the study aimed to evaluate the accuracy of VMC as a viable alternative for biomechanical research. METHODS: Eighteen healthy subjects performed isolated movements with 17 joint degrees of freedom, and their kinematic data were collected using both an MMC and a VMC setup. The kinematic data were entered into the AnyBody Modelling System, which enables the calculation of joint angles. The mean absolute error (MAE) was calculated to quantify the deviations between the two systems. RESULTS: The results showed good agreement between VMC and MMC at several joint angles. In particular, the shoulder, hip and knee joints showed small deviations in kinematics with MAE values of 4.8∘, 6.8∘ and 3.5∘, respectively. However, the study revealed problems in tracking hand and elbow movements, resulting in higher MAE values of 13.7∘ and 27.7∘. Deviations were also higher for head and thoracic movements. CONCLUSION: Overall, VMC showed promising results for lower body and shoulder kinematics. However, the tracking of the wrist and pelvis still needs to be refined. The research results provide a basis for further investigations that promote the fusion of VMC and musculoskeletal models. KW - biomechanics KW - range of motion KW - musculoskeletal system KW - optical motion capture Y1 - 2024 U6 - https://doi.org/10.3233/THC-240202 SN - 0928-7329 N1 - Corresponding author der OTH Regensburg: Sebastian Dendorfer SP - 1 EP - 10 PB - IOS Press ER -