TY - JOUR A1 - Thema, Martin A1 - Weidlich, Tobias A1 - Hörl, Manuel A1 - Bellack, Annett A1 - Mörs, Friedemann A1 - Hackl, Florian A1 - Kohlmayer, Matthias A1 - Gleich, Jasmin A1 - Stabenau, Carsten A1 - Trabold, Thomas A1 - Neubert, Michael A1 - Ortloff, Felix A1 - Brotsack, Raimund A1 - Schmack, Doris A1 - Huber, Harald A1 - Hafenbradl, Doris A1 - Karl, Jürgen A1 - Sterner, Michael T1 - Biological CO2-Methanation: An Approach to Standardization JF - Energies N2 - Power-to-Methane as one part of Power-to-Gas has been recognized globally as one of the key elements for the transition towards a sustainable energy system. While plants that produce methane catalytically have been in operation for a long time, biological methanation has just reached industrial pilot scale and near-term commercial application. The growing importance of the biological method is reflected by an increasing number of scientific articles describing novel approaches to improve this technology. However, these studies are difficult to compare because they lack a coherent nomenclature. In this article, we present a comprehensive set of parameters allowing the characterization and comparison of various biological methanation processes. To identify relevant parameters needed for a proper description of this technology, we summarized existing literature and defined system boundaries for Power-to-Methane process steps. On this basis, we derive system parameters providing information on the methanation system, its performance, the biology and cost aspects. As a result, three different standards are provided as a blueprint matrix for use in academia and industry applicable to both, biological and catalytic methanation. Hence, this review attempts to set the standards for a comprehensive description of biological and chemical methanation processes. KW - Biological methanation KW - bubble column reactor KW - CO2-methanation KW - CSTR KW - membrane reactor KW - methanation KW - Power-to-Gas KW - Power-to-Methane KW - standardization KW - Trickle-bed reactor Y1 - 2019 U6 - https://doi.org/10.3390/en12091670 N1 - Corresponding author: Martin Thema VL - 12 IS - 9 SP - 1 EP - 32 PB - MDPI ER - TY - JOUR A1 - Haug, Sonja A1 - Lochner, Susanne A1 - Huber, Dominik T1 - Methodological Aspects of a Quantitative and Qualitative Survey of Asylum Seekers in Germany BT - A Field Report JF - mda - methods data analyses N2 - This field report presents and discusses methodological issues and challenges encountered in a mixed-methods research project on asylum seekers in Bavaria, Germany. It documents the research design of, and field experiences in, a quantitative survey based on a quota sampling procedure and a qualitative study, both of which were conducted in collective accommodation for asylum seekers at selected locations in that federal state. Standardized PAPI multiple-topic questionnaires were completed by asylum seekers from Syria, Afghanistan, Eritrea, and Iraq (N = 779); most of the questionnaires were self-administered. In addition, 12 qualitative face-to-face biographical interviews were conducted in order to gain an in-depth understanding of attitudes and experiences of asylum seekers. This report focuses on the following aspects: the use of gatekeepers to facilitate participant recruitment; sampling procedures; the involvement of interpreters in the data collection process; response bias and response behaviors among asylum seekers; and the experiences gained from data collection in collective accommodation for asylum seekers. KW - asylum seekers in Germany KW - biographical research KW - gatekeeper approach KW - methodological issues KW - mixed methods KW - surveys KW - use of interpreters Y1 - 2019 U6 - https://doi.org/10.12758/mda.2019.02 N1 - Corresponding author: Sonja Haug VL - 13 IS - 2 SP - 321 EP - 340 PB - GESIS – Leibniz-Institut für Sozialwissenschaften ER - TY - JOUR A1 - Prem, Nina A1 - Sindersberger, Dirk A1 - Monkman, Gareth J. T1 - Mini-Extruder for 3D Magnetoactive Polymer Printing JF - Advances in Materials Science and Engineering N2 - This work describes the development of a new miniature extruder, essential to cavity-free 3D printing of silicone-based smart materials. This makes the 3D printing of magnetoactive and electroactive polymer soft robotic components and devices directly from CAD data possible. The special feature of such an extruder is that it is designed for use with addition-crosslinking RTV-2 silicones, including solid particulate additives. The extruder merges the respective components automatically during extrusion which obviates the need for premixing and vacuum evacuation. Problems associated with inhomogeneities and unwanted cavity production are consequently eliminated. Rheological details necessary to the design, together with some preliminary performance results, are presented. Y1 - 2019 U6 - https://doi.org/10.1155/2019/8715718 N1 - Corresponding author: Gareth J. Monkman SP - 1 EP - 8 PB - HINDAWI ER - TY - JOUR A1 - Monkman, Gareth J. A1 - Sindersberger, Dirk A1 - Prem, Nina A1 - Szecsey, Tamara T1 - Smart Stiction JF - Robotics & Automation Engineering Journal N2 - Soft robotics could loosely be described as the engineering science of expanded dexterity through controllable flexibility. The exploitation of controllable compliance through the judicious choice of soft flexible members, as opposed to a finite number of rigid kinematic joints, can result in greater dexterity without compromising simplicity. One example is the replacement of segmented mechanical legs with simple compliant material eruciform prolegs. To achieve this in robotics, without introducing additional mechanical joints, mobile surfaces with switchable coefficients of friction is essential. This paper explains how, using silicone based smart materials, the rapid alternation between kinematic and static friction (stiction) may be achieved. Y1 - 2019 U6 - https://doi.org/10.19080/RAEJ.2019.04.555641 N1 - Corresponding author: Gareth J. Monkman VL - 4 IS - 4 PB - Juniper Publishers ER - TY - JOUR A1 - Sindersberger, Dirk A1 - Prem, Nina A1 - Monkman, Gareth J. T1 - Structure formation in low concentration magnetoactive polymers JF - AIP advances N2 - This paper concerns recent research into the autonomous formation of micro-structures in low carbonyl iron powder (CIP) concentration magneto active polymers (MAP). Higher concentrations of CIP show an isotropic distribution of magnetic filler throughout the entire sample, while autonomous structure formation is possible at mass concentrations lower than 3%. The formation of micro-toroids commences as CIP concentration approaches 1% wt. Further development of coherent rings with a defined order follow as CIP concentrations increase toward 2% wt, whilst exceeding 3% wt leads to the same isotropic distribution found in higher concentration MAP. Structured samples containing between 1% wt and 3% wt CIP were investigated using X-Ray tomography where solitary structures could clearly be observed. The ring structures represent microinductivities whose geometries can be manipulated during fabrication. In addition, these structures are magnetic field sensitive. This is not only relevant to applications in the GHz and THz areas but recent research has revealed implications for optical, thermal, acoustic and even chemical MAP sensors. (C) 2019 Author(s). Y1 - 2019 U6 - https://doi.org/10.1063/1.5079997 N1 - Corresponding author: Dirk Sindersberger VL - 9 IS - 3 PB - AIP Publishing ER - TY - JOUR A1 - Thema, Martin A1 - Bauer, Franz A1 - Sterner, Michael T1 - Power-to-Gas: Electrolysis and methanation status review JF - Renewable and Sustainable Energy Reviews N2 - This review gives a worldwide overview on Power-to-Gas projects producing hydrogen or renewable substitute natural gas focusing projects in central Europe. It deepens and completes the content of previous reviews by including hitherto unreviewed projects and by combining project names with details such as plant location. It is based on data from 153 completed, recent and planned projects since 1988 which were evaluated with regards to plant allocation, installed power development, plant size, shares and amounts of hydrogen or substitute natural gas producing examinations and product utilization phases. Cost development for electrolysis and carbon dioxide methanation was analyzed and a projection until 2030 is given with an outlook to 2050. The results show substantial cost reductions for electrolysis as well as for methanation during the recent years and a further price decline to less than 500 euro per kilowatt electric power input for both technologies until 2050 is estimated if cost projection follows the current trend. Most of the projects examined are located in Germany, Denmark, the United States of America and Canada. Following an exponential global trend to increase installed power, today's Power-to-Gas applications are operated at about 39 megawatt. Hydrogen and substitute natural gas were investigated on equal terms concerning the number of projects. KW - Biological CO2-Methanation KW - Chemical CO2-Methanation KW - Cost-development KW - Electrolysis KW - Power-to-Gas Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-26238 N1 - Corresponding author: Martin Thema VL - 112 IS - 7 SP - 775 EP - 787 PB - Elsevier ER - TY - JOUR A1 - Glavan, Gašper A1 - Kettl, Wolfgang A1 - Brunhuber, Alexander A1 - Shamonin (Chamonine), Mikhail A1 - Drevenšek‐Olenik, Irena T1 - Effect of Material Composition on Tunable Surface Roughness of Magnetoactive Elastomers JF - Polymers N2 - We investigated magnetic-field-induced modifications of the surface roughness of magnetoactive elastomers (MAEs) with four material compositions incorporating two concentrations of ferromagnetic microparticles (70 wt% and 80 wt%) and exhibiting two shear storage moduli of the resulting composite material (about 10 kPa and 30 kPa). The analysis was primarily based on spread optical reflection measurements. The surfaces of all four materials were found to be very smooth in the absence of magnetic field (RMS roughness below 50 nm). A maximal field-induced roughness modification (approximately 1 m/T) was observed for the softer material with the lower filler concentration, and a minimal modification (less than 50 nm/T) was observed for the harder material with the higher filler concentration. All four materials showed a significant decrease in the total optical reflectivity with an increasing magnetic field as well. This effect is attributed to the existence of a distinct surface layer that is depleted of microparticles in the absence of a magnetic field but becomes filled with particles in the presence of the field. We analyzed the temporal response of the reflective properties to the switching on and off of the magnetic field and found switching-on response times of around 0.1 s and switching-off response times in the range of 0.3-0.6 s. These observations provide new insight into the magnetic-field-induced surface restructuring of MAEs and may be useful for the development of magnetically reconfigurable elastomeric optical surfaces. KW - magnetically tunable surface reflectivity KW - magnetically tunable surface roughness KW - magnetorheological elastomer KW - magnetorheological polymers KW - surface properties Y1 - 2019 U6 - https://doi.org/10.3390/polym11040594 N1 - Corresponding author: Gašper Glavan VL - 11 IS - 4 SP - 1 EP - 13 PB - MDPI CY - Basel ER - TY - JOUR A1 - Fetisov, Yuri K. A1 - Chashin, Dmitri V. A1 - Savelev, Dmitrii V. A1 - Fetisov, Leonid Y. A1 - Shamonin (Chamonine), Mikhail T1 - Anisotropic Magnetoelectric Effect in a Planar Heterostructure Comprising Piezoelectric Ceramics and Magnetostrictive Fibrous Composite JF - Materials N2 - The direct magnetoelectric (ME) effect is investigated in a planar structure comprising mechanically coupled layers of a magnetostrictive fibrous composite (MFC) and a piezoelectric ceramics (lead zirconate titanate, PZT). The MFC is an array of Ni-wires with a diameter of 200 mu m that are aligned parallel to each other in a single layer. The wires are separated by a distance of 250 or 500 mu m and fixed in a polyamide matrix. The structure was placed in a tangential constant field H and was excited by an alternating magnetic field h parallel to H, while the voltage generated by the PZT layer was measured. The resulting field dependences of the magnetization M(H) and the magnetostriction lambda(H) were determined by the orientation of the field H in the plane of the structure and the distance between the Ni-wires. The ME coupling coefficient of the structure decreased from 4.8 to 0.25 V/A when the orientation of H was changed from parallel to perpendicular to Ni-wires. With an increase in the excitation field amplitude h, a nonlinear ME effect in the output voltage, namely frequency doubling, was observed. The frequency and field dependences of the efficiency of the ME transduction in the MFC-piezoelectric heterostructure are well described by the existing theory. KW - composite KW - frequency doubling KW - heterostructure KW - magnetoelectric effect KW - magnetostrictive fiber KW - piezoelectric ceramic material Y1 - 2019 U6 - https://doi.org/10.3390/ma12193228 N1 - Corresponding authors: Yuri Fetisov, Mikhail Shamonin VL - 12 IS - 19 SP - 1 EP - 13 PB - MDPI CY - Basel ER - TY - JOUR A1 - Maier, Johannes A1 - Perret, Jerome A1 - Simon, Martina A1 - Schmitt-Rüth, Stephanie A1 - Wittenberg, Thomas A1 - Palm, Christoph T1 - Force-feedback assisted and virtual fixtures based K-wire drilling simulation JF - Computers in Biology and Medicine N2 - One common method to fix fractures of the human hand after an accident is an osteosynthesis with Kirschner wires (K-wires) to stabilize the bone fragments. The insertion of K-wires is a delicate minimally invasive surgery, because surgeons operate almost without a sight. Since realistic training methods are time consuming, costly and insufficient, a virtual-reality (VR) based training system for the placement of K-wires was developed. As part of this, the current work deals with the real-time bone drilling simulation using a haptic force-feedback device. To simulate the drilling, we introduce a virtual fixture based force-feedback drilling approach. By decomposition of the drilling task into individual phases, each phase can be handled individually to perfectly control the drilling procedure. We report about the related finite state machine (FSM), describe the haptic feedback of each state and explain, how to avoid jerking of the haptic force-feedback during state transition. The usage of the virtual fixture approach results in a good haptic performance and a stable drilling behavior. This was confirmed by 26 expert surgeons, who evaluated the virtual drilling on the simulator and rated it as very realistic. To make the system even more convincing, we determined real drilling feed rates through experimental pig bone drilling and transferred them to our system. Due to a constant simulation thread we can guarantee a precise drilling motion. Virtual fixtures based force-feedback calculation is able to simulate force-feedback assisted bone drilling with high quality and, thus, will have a great potential in developing medical applications. KW - Handchirurgie KW - Osteosynthese KW - Operationstechnik KW - Lernprogramm KW - Virtuelle Realität KW - Medical training system KW - Virtual fixtures KW - Virtual reality KW - Force-feedback haptic KW - Minimally invasive hand surgery KW - K-wire drilling Y1 - 2019 U6 - https://doi.org/10.1016/j.compbiomed.2019.103473 N1 - Corresponding author: Christoph Palm VL - 114 SP - 1 EP - 10 PB - Elsevier ER - TY - JOUR A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph T1 - Imitating human soft tissue on basis of a dual-material 3D print using a support-filled metamaterial to provide bimanual haptic for a hand surgery training system JF - Quantitative Imaging in Medicine and Surgery N2 - Background: Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D-printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. Methods: The goal of this experiment is to imitate human soft tissue with its haptic and elasticity for a realistic hand phantom fabrication, using only a dual-material 3D printer and support-material-filled metamaterial between skin and bone. We present our workflow to generate lattice structures between hard bone and soft skin with iterative cube edge (CE) or cube face (CF) unit cells. Cuboid and finger shaped sample prints with and without inner hard bone in different lattice thickness are constructed and 3D printed. Results: The most elastic available rubber-like material is too firm to imitate soft tissue. By reducing the amount of rubber in the inner volume through support material (SUP), objects become significantly softer. Without metamaterial, after disintegration, the SUP can be shifted through the volume and thus the body loses its original shape. Although the CE design increases the elasticity, it cannot restore the fabric form. In contrast to CE, the CF design increases not only the elasticity but also guarantees a local limitation of the SUP. Therefore, the body retains its shape and internal bones remain in its intended place. Various unit cell sizes, lattice thickening and skin thickness regulate the rubber material and SUP ratio. Test prints with higher SUP and lower rubber material percentage appear softer and vice versa. This was confirmed by an expert surgeon evaluation. Subjects adjudged pure rubber-like material as too firm and samples only filled with SUP or lattice structure in CE design as not suitable for imitating tissue. 3D-printed finger samples in CF design were rated as realistic compared to the haptic of human tissue with a good palpable bone structure. Conclusions: We developed a new dual-material 3D print technique to imitate soft tissue of the human hand with its haptic properties. Blowy SUP is trapped within a lattice structure to soften rubber-like 3D print material, which makes it possible to reproduce a realistic replica of human hand soft tissue. KW - Dual-material 3D printing KW - Hand surgery training KW - Metamaterial KW - Support material KW - Tissue-imitating hand phantom KW - Handchirurgie KW - 3D-Druck KW - Biomaterial KW - Lernprogramm Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-979 N1 - Corresponding author: Christoph Palm VL - 9 IS - 1 SP - 30 EP - 42 PB - AME Publishing Company ER - TY - JOUR A1 - Ebigbo, Alanna A1 - Mendel, Robert A1 - Probst, Andreas A1 - Manzeneder, Johannes A1 - Souza Jr., Luis Antonio de A1 - Papa, João Paulo A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Computer-aided diagnosis using deep learning in the evaluation of early oesophageal adenocarcinoma JF - GuT N2 - Computer-aided diagnosis using deep learning (CAD-DL) may be an instrument to improve endoscopic assessment of Barrett’s oesophagus (BE) and early oesophageal adenocarcinoma (EAC). Based on still images from two databases, the diagnosis of EAC by CAD-DL reached sensitivities/specificities of 97%/88% (Augsburg data) and 92%/100% (Medical Image Computing and Computer-Assisted Intervention [MICCAI] data) for white light (WL) images and 94%/80% for narrow band images (NBI) (Augsburg data), respectively. Tumour margins delineated by experts into images were detected satisfactorily with a Dice coefficient (D) of 0.72. This could be a first step towards CAD-DL for BE assessment. If developed further, it could become a useful adjunctive tool for patient management. KW - Speiseröhrenkrebs KW - Diagnose KW - Computerunterstütztes Verfahren KW - Maschinelles Lernen Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-68 N1 - Corresponding authors: Alanna Ebigbo and Christoph Palm VL - 68 IS - 7 SP - 1143 EP - 1145 PB - British Society of Gastroenterology ER -