TY - JOUR A1 - Pangerl, Jonas A1 - Sukul, Pritam A1 - Rück, Thomas A1 - Fuchs, Patricia A1 - Weigl, Stefan A1 - Miekisch, Wolfram A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone JF - Photoacoustics N2 - n this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) – providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 8.3 ppbV and an NNEA of 1.4E-9 Wcm 1Hz 0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field. KW - Photoacoustic spectroscopy KW - Real-time mass-spectrometry KW - Breath analysis KW - Acetone KW - UV-LED Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-71279 SN - 2213-5979 N1 - Corresponding author der OTH Regensburg: Jonas Pangerl VL - 38 PB - Elsevier ER - TY - JOUR A1 - Escher, Lukas A1 - Rück, Thomas A1 - Jobst, Simon A1 - Pangerl, Jonas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Photodissociation-Driven Photoacoustic Spectroscopy with UV-LEDs for Ozone Detection JF - Photoacoustics N2 - This study presents the development and evaluation of a UV-LED based photoacoustic (PA) measurement system for ozone (O3) detection to demonstrate its potential for low-cost and accurate sensing while for the first time addressing the importance of photodissociation for PA signal generation for O3 in the UV range. With a detection limit of 7.9 ppbV, the system exhibits a significant advancement over state-of-the-art UV-PA O3 detection and is on par with laser-based setups. Following a novel discussion of the PA signal arising from photodissociation and its products, cross-sensitivity effects due to environmental factors such as temperature and gas composition were systematically analyzed. A digital twin driven compensation for these influences was implemented and evaluated. Despite the challenges associated with modeling the effects of H2O and CO2, the PA system shows considerable potential, though further studies in real world applications must be conducted. KW - Photoacoustic spectroscopy KW - UV-LED KW - Ozone KW - Photodissociation KW - Cross-sensitivity Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-80076 SN - 2213-5979 N1 - Corresponding author der OTH Regensburg: Lukas Escher VL - 43 PB - Elsevier BV ER - TY - JOUR A1 - Hausler, Peter A1 - Holzner, Lukas A1 - Ehrnsperger, Matthias A1 - Bierl, Rudolf T1 - Evaluation of the creep strength of samples produced by fused deposition modeling JF - Open Engineering N2 - Data sheets for 3D printing materials typically include softening temperature, impact strength, tensile strength, and stiffness. However, creep strength, an important parameter for components used over an extended period, is usually not included. Nevertheless, this parameter is of significant importance for components that are used over an extended period of time.This study compares the long-term creep behavior of a selection of materials that are commonly used in fused deposition modeling 3D printing. The materials under investigation are acrylonitrile butadiene styrene, acrylonitrile styrene acrylate, polylactic acid, and polycarbonate. In addition, the influence of fiber reinforcements on these materials is also examined. A simple, reproducible test procedure is proposed for users to determine and compare creep resistance of materials. This enables developers to select materials suitable for their own requirements on creep resistance and allows 3D-printing users to compare different materials. Results suggest that fiber reinforcement generally improves creep stability in 3D-printing materials, with GreenTEC Pro Carbon and add:north PC Blend HT LCF showing the most promise in this study. Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-79760 N1 - Corresponding author der OTH Regensburg: Peter Hausler VL - 14 IS - 1 PB - de Gruyter ER - TY - JOUR A1 - Schels, Andreas A1 - Edler, Simon A1 - Herdl, Florian A1 - Hansch, Walter A1 - Bachmann, Michael A1 - Ritter, Daniela A1 - Dudeck, Markus A1 - Duesberg, Felix A1 - Meyer, Manuel A1 - Pahlke, Andreas A1 - Hausladen, Matthias A1 - Buchner, Philipp A1 - Schreiner, Rupert T1 - In situ quantitative field emission imaging using a low-cost CMOS imaging sensor JF - Journal of Vacuum Science & Technology B N2 - Spatially resolved field emission measurements represent an important factor in further development of existing field emitter concepts. In this work, we present a novel approach that allows quantitative analysis of individual emission spots from integral current-voltage measurements using a low-cost and commercially available CMOS camera. By combining different exposure times to extrapolate oversaturated and underexposed pixels, a near congruence of integral current and image brightness is shown. The extrapolation also allows parallel investigation of all individual tips participating in the total current with currents ranging from a few nanoampere to one microampere per tip. The sensitivity, which is determined by the integral brightness-to-current ratio, remains unchanged within the measurement accuracy even after ten full measurement cycles. Using a point detection algorithm, the proportional current load of each individual tip of the field emitter array is analyzed and compared at different times during the initial measurement cycle. Together with the extracted I-V curves of single emission spots from the integral measurement, the results indicate the effect of premature burnout of particularly sharp tips during conditioning of the emitter. KW - ARRAYS KW - ELECTRON-EMISSION KW - EMITTERS KW - FakANK Y1 - 2022 U6 - https://doi.org/10.1116/6.0001551 VL - 40 IS - 1 PB - AIP Publishing ER - TY - JOUR A1 - Engelhardt, Lucas A1 - Melzner, Maximilian A1 - Havelkova, Linda A1 - Fiala, Pavel A1 - Christen, Patrik A1 - Dendorfer, Sebastian A1 - Simon, Ulrich T1 - A new musculoskeletal AnyBodyTM detailed hand model JF - Computer Methods in Biomechanics and Biomedical Engineering N2 - Musculoskeletal research questions regarding the prevention or rehabilitation of the hand can be addressed using inverse dynamics simulations when experiments are not possible. To date, no complete human hand model implemented in a holistic human body model has been fully developed. The aim of this work was to develop, implement, and validate a fully detailed hand model using the AnyBody Modelling System (AMS) (AnyBody, Aalborg, Denmark). To achieve this, a consistent multiple cadaver dataset, including all extrinsic and intrinsic muscles, served as a basis. Various obstacle methods were implemented to obtain with the correct alignment of the muscle paths together with the full range of motion of the fingers. These included tori, cylinders, and spherical ellipsoids. The origin points of the lumbrical muscles within the tendon of the flexor digitorum profundus added a unique feature to the model. Furthermore, the possibility of an entire patient-specific scaling based on the hand length and width were implemented in the model. For model validation, experimental datasets from the literature were used, which included the comparison of numerically calculated moment arms of the wrist, thumb, and index finger muscles. In general, the results displayed good comparability of the model and experimental data. However, the extrinsic muscles showed higher accordance than the intrinsic ones. Nevertheless, the results showed, that the proposed developed inverse dynamics hand model offers opportunities in a broad field of applications, where the muscles and joint forces of the forearm play a crucial role. KW - Musculoskeletal KW - hand KW - AnyBody KW - inverse dynamics KW - moment arm Y1 - 2020 U6 - https://doi.org/10.1080/10255842.2020.1851367 VL - 24 IS - 7 SP - 777 EP - 787 PB - Taylor & Francis ER - TY - CHAP A1 - Tschurtschenthaler, Karl A1 - Krenkel, Lars A1 - Schreiner, Rupert T1 - Mechano-optical micro pillar sensor for biofluidmechanic wall shear stress measurements T2 - 25th Congress of the European Society of Biomechanics (ESB), July 7-10, 2019, Vienna, Austria Y1 - 2019 UR - https://esbiomech.org/conference/archive/2019vienna/Contribution_608.pdf ER - TY - CHAP A1 - Weber, Karsten ED - Kerkelmann, Friederike ED - Lewandowski, Dirk T1 - Alternative Benutzerschnittstellen als Möglichkeit der Kompensation sensorischer Handicaps T2 - Barrierefreie Informationssysteme: Zugänglichkeit für Menschen mit Behinderung in Theorie und Praxis Y1 - 2015 U6 - https://doi.org/10.1515/9783110337297-004 SP - 49 EP - 70 PB - de Gruyter CY - Berlin ER - TY - CHAP A1 - Prommesberger, Christian A1 - Langer, Christoph A1 - Schreiner, Rupert T1 - Stable and low noise field emission from single p-type Si-tips T2 - International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan N2 - Single gated p-type Si-tips with two different tip radii were fabricated. An emission current of 2.40 μA was measured for the sharp-edged tip at a voltage of 170 V. In contrast, a stable and reproducible emission behavior was observed with an increased tip radius resulting in a pronounced saturation region between 90 V and 150 V, but merely an emission current of 0.55 μA at 150 V. More remarkable is the stable emission behavior with fluctuation of ± 4 % during a measurement period of 30 minutes. The integral emission current in a homogeneous tip array (16 emitters) showed nearly the same I-V characteristics compared to the single tip and is therefore, most dominated by only a stable single tip in the array. KW - field emission KW - p-type Si-tips KW - gate-electrode KW - emission stability KW - low current fluctuations Y1 - 2018 U6 - https://doi.org/10.1109/IVNC.2018.8520018 PB - IEEE ER - TY - CHAP A1 - Lindner, Matthias A1 - Berndt, Dominik A1 - Prommesberger, Christian A1 - Langer, Christoph A1 - Schreiner, Rupert T1 - Field emission assisted micro plasma discharges at vacuum and atmospheric pressures T2 - 31st International Vacuum Nanoelectronics Conference (IVNC), 2018, Kyoto, Japan N2 - Spatially confined non-equilibrium plasmas at vacuum and atmospheric pressure in the dimensions from a few microns to one millimeter are a promising approach to the generation and maintenance of stable glow discharges. The realization of these micro-discharges or micro-plasmas enable more accurate investigations in the field of micro plasma research. We report on field emission assisted micro plasmas excited by an alternating current with frequencies up to 1 kHz. Due to the field enhancement caused by an array of Si nano-tip structures the ignition voltage of stable plasma discharges can be reduced by 30%. Y1 - 2018 U6 - https://doi.org/10.1109/IVNC.2018.8520181 ER - TY - CHAP A1 - Berndt, Dominik A1 - Lindner, Matthias A1 - Tschurtschenthaler, Karl A1 - Langer, Christoph A1 - Schreiner, Rupert T1 - Miniaturized Plasma Actuator Flow Measurements by MEMS-Based Thermal Conductivity Sensors T2 - MDPI Proceedings of Eurosensors 2018, 9-12 September, Graz N2 - The gasflow created by a minaturized dielectric barrier discharge (DBD) plasma actuator is measured by a MEMS-based thermal conductivity gas sensor giving an indication of flow velocity and flow direction. The possiblity of several sensors in a small area gives a far better accuracy of local flow phenomena compared to conventional sensors. This is important for a better understanding of plasma- induced flow characteristics. KW - thermal conductivity sensors; plasma actuators; surface hotfilms; sensors for aerospace Y1 - 2018 U6 - https://doi.org/10.3390/proceedings2130939 VL - Vol.13 IS - 2 ER - TY - CHAP A1 - Steindl, Michael A1 - Mottok, Jürgen A1 - Meier, Hans A1 - Schiller, Frank A1 - Früchtl, M. T1 - Safeguarded Processing of Sensor Data T2 - IT-SecurityArea (IT-SA 2009) vom 13.-15. Oktober 2009, Nürnberg N2 - The spectrum of software tasks no longer includes only rare function controlling tasks for sensor actuator chains in reactive embedded systems. However, more and more responsible challenges like safety-critical scenarios are tackled. Therefore sensor data have to be safeguarded by several mechanism. An obvious and widely used approach is the use of two redundant hardware controllers, but this comes along with an additional cost, space and energy factor. Another way to fulfill certain safety properties is to implement a second diverse software channel in a single micro-controller architecture according the Safely Embedded Software (SES) approach. However, a lack of performance occurs by implementing this diverse channel for complex computations e.g. floating-point operations. This paper gives an approach for transferring the SES into a coprocessor and to migrate SES to a flexible and powerful FPGA architecture. KW - Safety embedded software KW - FPGA KW - Diverse instructions KW - Safety code weaving Y1 - 2009 UR - https://hal.archives-ouvertes.fr/hal-02268737 ER - TY - CHAP A1 - Steindl, Michael A1 - Mottok, Jürgen A1 - Meier, Hans A1 - Schiller, Frank A1 - Früchtl, M. T1 - Safeguarded Processing of Sensor Data T2 - 5th Embedded Real Time Software and Systems Conference (ERTS2 2010), May 2010, Toulouse, France Y1 - 2010 ER - TY - CHAP A1 - Edler, Simon A1 - Hansch, Walter A1 - Prommesberger, Christian A1 - Schreiner, Rupert T1 - Influence of adsorbates on the performance of a field emitter array in a high voltage triode setup T2 - International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan N2 - The influence of residual gas pressure on the characteristics of black-Silicon field emitter arrays in a high voltage triode setup is investigated. I-Vcharacteristics at different pressure levels show a decrease of emission current with rising pressure. This can be explained by an increase of the work function and charging of the emitter surface due to adsorbates. The initial characteristics can be restored by heating the FEA up to 110 °C during electron emission. This regeneration procedure enables an extension of the lifetime from about 20 h to 440 h at a residual gas pressure of 10 -5 mbar. KW - semiconductor field emission KW - field emitter array KW - silicon tips KW - emission current stability Y1 - 2018 U6 - https://doi.org/10.1109/IVNC.2018.8520214 PB - IEEE ER - TY - CHAP A1 - Käsbauer, Johannes A1 - Schmailzl, Anton A1 - Prehm, Jens A1 - Loose, Tobias A1 - Hierl, Stefan T1 - Simulation of Quasi-Simultaneous Laser Transmission Welding of Plastics BT - Optimization of Material Parameters in Broad Temperature Range T2 - Procedia CIRP N2 - Thermo-mechanical simulation offers great opportunities to optimize welding processes of plastics. For realistic simulation, the temperature dependent mechanical properties need to be implemented from ambient temperature to temperatures above the flow temperature. Standard test methods are insufficient for characterization in the entire temperature range because close to the flow temperature the material is too soft for tensile tests and too stiff for rheometry. Therefore, an optimization strategy is developed, that determines unknown material parameters by testing in welding simulations. The unknown parameters are iteratively adjusted to minimize the mismatch between computed and measured set-paths. Thus, important process characteristics are calculated realistically, enabling the computer aided assessment of the weld quality. KW - plastics welding KW - simulation KW - material modelling KW - optimization KW - parameterization KW - Kunststoffschweißen KW - Thermomechanische Eigenschaft KW - Simulation Y1 - 2020 U6 - https://doi.org/10.1016/j.procir.2020.09.136 VL - 94 SP - 737 EP - 741 PB - Elsevier ER - TY - JOUR A1 - Weigl, Stefan A1 - Feldmeier, Florian A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Photoacoustic detection of acetone in N2 and synthetic air using a high power UV LED JF - Sensors Actuators B Chemical N2 - The performance of a photoacoustic trace gas sensor for the detection of acetone in N2 and synthetic air is reported. The sensor system utilises an amplitude modulated UV LED. The light source has an emission maximum at 278 nm and a maximum CW output power of 300 mW according to the datasheet. Three different collimating and focusing approaches have been investigated to guide the highly divergent LED light into the acoustic resonator of the photoacoustic measurement cell. A 3D printed aluminium cell was designed to optimize light coupling by simultaneously minimizing the photoacoustic background signal generation. Hence, the diameter of the resonator was set to a comparable large diameter of 10 mm and the inner walls of the resonator were mirror polished. The additive manufacturing procedure allowed for integration of a spirally formed gas channel, enabling gas heating prior to detection. The sensor performance was investigated by measuring acetone in N2 and synthetic air at different concentrations. The UV LED current was set to 86 % of the maximum value according to the datasheet of the light source in order to increase the lifetime and thermal stability. An Allan-Werle deviation analysis validates a stable sensor performance. The limit of detection (LoD) was determined at a 3σ noise level with a 10 s lock-in amplifier time constant by sampling data points over 20 s with a data acquisition rate of 5 Hz. LoDs of 80.8 ppbV and 19.6 ppbV were obtained for acetone in N2 and synthetic air, respectively. KW - Acetone detection KW - Photoacoustic spectroscopy KW - High power UV LED KW - UV LED collimation system KW - Acetone breath analysis Y1 - 2020 U6 - https://doi.org/10.1016/j.snb.2020.128109 N1 - Corresponding author at: Sensorik-Applikationszentrum (SappZ) der Ostbayerischen Technischen Hochschule Regensburg VL - 316 IS - August SP - 1 EP - 11 PB - Elsevier ER - TY - JOUR A1 - Berndt, Dominik A1 - Muggli, Josef A1 - Wittwer, Franz A1 - Langer, Christoph A1 - Heinrich, Stephan A1 - Knittel, Thorsten A1 - Schreiner, Rupert T1 - MEMS-based thermal conductivity sensor for hydrogen gas detection in automotive applications JF - Sensors and Actuators A: Physical N2 - Accurate detection of hydrogen gas in vehicle interiors is very important for the future of a fuel cell car. Since this type of gas is highly volatile and flammable, the measurement methods have to be very reliable and precise due to safety reasons. In this paper a thermal conductivity sensor for hydrogen gas detection is presented, exhibiting a lower detection limit of 2000 ppm hydrogen in laboratory air. The sensor element is realized by micro-fabrication techniques on silicon wafers. The heated filament is exposed by a selective wet etching process creating a micro-hotplate on a thin membrane. In order to minimize power consumption, the sensor is operated in pulsed mode. Hydrogen gas detection was carried out using a synthetic gas testbench. Measurements of hydrogen contents ranging from 0% to 4% with an increment of 0.5% were successfully performed for ambient gas temperatures between -15°C and 84°C. Including humidity, high moisture contents have the greatest influence on thermal conductivity. This was predicted in theoretical investigations and confirmed in experiments. For evaluation, both the change in resistance ΔR as well as the time constant τ were taken as sensor output. For both quantities, the previously established theoretical relationship with thermal conductivity could be confirmed. Y1 - 2020 U6 - https://doi.org/10.1016/j.sna.2019.111670 VL - 305 IS - April PB - Elsevier ER -