TY - JOUR A1 - Pangerl, Jonas A1 - Müller, Max A1 - Rück, Thomas A1 - Weigl, Stefan A1 - Bierl, Rudolf T1 - Characterizing a sensitive compact mid-infrared photoacoustic sensor for methane, ethane and acetylene detection considering changing ambient parameters and bulk composition (N2, O2 and H2O) JF - Sensors and Actuators B: Chemical N2 - We present a sensitive and compact interband cascade laser (ICL) based photoacoustic setup for the detection of gaseous hydrocarbons and discuss its applicability towards trace gas analysis. We investigated the performance of the sensor for trace concentrations of methane, ethane and acetylene diluted in nitrogen. The excitation of methane and ethane was accomplished using one tunable diode laser, covering a range from 3360 to 3372 nm, which was replaced by a separate ICL at 3025 nm for acetylene detection. The influence of ambient parameters such as temperature, flow rate and pressure as well as potential cross-sensitivities towards O2 and H2O have been examined in terms of methane and acetylene detection. A series of simulations proved several of these influences to be attributed to relaxation effects. With a 3σ limit of detection (LoD) of 6.8 parts per billion (ppbV) in case of methane, 2.3 ppbV regarding ethane and 3.6 ppbV in terms of acetylene, the sensor demonstrates a great potential for applications in the field of trace gas analysis. KW - Acetylene KW - Cross-sensitivities KW - Ethane KW - Interband cascade laser KW - Methane KW - Photoacoustic spectroscopy KW - Relaxation effects Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-25868 N1 - Corresponding author: Jonas Pangerl VL - 352,1 SP - 1 EP - 12 PB - Elsevier ER - TY - JOUR A1 - Müller, Max A1 - Rück, Thomas A1 - Jobst, Simon A1 - Pangerl, Jonas A1 - Weigl, Stefan A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - An Algorithmic Approach to Compute the Effect of Non-Radiative Relaxation Processes in Photoacoustic Spectroscopy JF - Photoacoustics N2 - Successful transfer of photoacoustic gas sensors from laboratory to real-life applications requires knowledge about potential cross-sensitivities towards environmental and gas matrix changes. Multi-dimensional calibration in case of cross-sensitivities can become very complex or even unfeasible. To address this challenge, we present a novel algorithm to compute the collision based non-radiative efficiency and phase lag of energy relaxation on a molecular level (CoNRad) for photoacoustic signal calculation. This algorithmic approach allows to calculate the entire elaxation cascade of arbitrarily complex systems, yielding a theoretical photoacoustic signal. In this work the influence of varying bulk compositions, i.e. nitrogen (N2), oxygen (O2) and water (H2O) on the photoacoustic signal during methane (CH4) detection is demonstrated. The applicability of the algorithm to other photoacoustic setups is shown exemplary by applying it to the relaxational system investigated in [1]. Hayden et al. examined the effect of water on photoacoustic carbon monoxide (CO) detection. Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-39935 N1 - Corresponding author: Max Müller VL - 26 PB - Elsevier ER - TY - CHAP A1 - Melekhov, Evgeny A1 - Abb, Valerius A1 - Lechner, Alfred A1 - Kammler, Martin ED - Ivanov, Artem ED - Bicker, Marc ED - Patzelt, Peter T1 - Development of a glass-fiber-based spectrometer for the determination of drug residues in groundwater T2 - Tagungsband 2. Symposium Elektronik und Systemintegration ESI 2020 "Intelligente Systeme und ihre Komponenten: Forschung und industrielle Anwendung" N2 - Within the scope of this project, a portable measuring device has been developed which enables a cost-effective analysis of organic substances from ppm to sub-ppm range, such as drug residues in groundwater. The measurement is carried out by means of a surface-enhanced Raman scattering effect (SERS effect) and an exchangeable sensor head. The sensor head used is a nanostructured optical glass fiber glued into a fiber cannula. The tip of the fiber has been processed to act as a SERS cell. The fiber cannula is connected to a freely movable patch cable by using an adapter. Para-thiocresol is used to characterize the SERS cells. Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:860-opus4-2174 SN - 978-3-9818439-4-1 SP - 101 EP - 109 ER - TY - CHAP A1 - Scherer, Leo A1 - Vitzthumecker, Thomas A1 - Bierl, Rudolf ED - Uhl, Christian ED - Walter, Michael ED - Stiehl, Annika T1 - Capacitive PCB sensor for the detection of insects in intelligent traps T2 - Applied Research Conference 2022 Conference Proceedings: 4th July 2022, University of Applied Sciences Ansbach (Onsite Conference) N2 - Reliable and fast detection of pest in the food processing and pharmaceutical industry is crucial to ensure hygienically safe, pure and healthy products. This is why intelligent traps, that are able to detect insects automatically are needed. For this, a capacitive PCB sensor is developed and tested, which could be a simplistic, low power solution to the problem. This includes design, footprint generation and simulation as well as testing different types of capacitve sensing against noise immunity and sensitivity to Blattella germanica, the German cockroach. It is shown that a single specimen can very well and reliably be detected by the developed sensor. KW - PCB layout generation KW - insect monitoring KW - pest detection KW - Capacitive sensing Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-55837 SP - 519 EP - 523 PB - Hochschule Ansbach CY - Ansbach ER - TY - JOUR A1 - Serbun, Pavel A1 - Bornmann, Benjamin A1 - Navitski, Aliaksandr A1 - Müller, Günter A1 - Prommesberger, Christian A1 - Langer, Christoph A1 - Dams, Florian A1 - Schreiner, Rupert T1 - Stable field emission of single B-doped Si tips and linear current scaling of uniform tip arrays for integrated vacuum microelectronic devices JF - Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics N2 - Advanced Si-based semiconductor technology is most suitable to fabricate uniform nanostructures as integrated field emitter arrays for novel vacuum electronic devices. In order to improve the field emission homogeneity and stability of p-type silicon tip arrays for pulsed sensor applications, the authors have systematically studied the influence of the fabrication parameters on the tip shape and on the specific operating conditions. Based on detailed design calculations of the field enhancement, they have fabricated two series of hexagonal arrays of B-doped Si-tips in a triangular arrangement. The first (second) type contains three (four) patches with different number of tips (1, 91, 547 and 1, 19, 1027, 4447 for the first and second type, respectively) of about 1 (2.5) μm height, ∼20 (20) nm apex radius, and 20 (10) μm pitch. The field emission properties of both individual tips and complete arrays were investigated with a field emission scanning microscope at a pressure of 10−9 mbar. The current plateau of these tips typically occurs at about 10 (3) nA and around 65 (25) V/μm field level. In this carrier saturation range, single tips provide the highest current stability (<5%) and optical current switching ratio (∼2.5). Fairly homogeneous emission of the tip arrays leads to an undershooting of the expected linear scaling of the mean plateau current as well as to a much improved current stability (<1%). Y1 - 2013 U6 - https://doi.org/10.1116/1.4765088 VL - 31 IS - 2 PB - AIP Publishing ER - TY - GEN A1 - Melekhov, Evgeny A1 - Abb, Valerius A1 - Weidauer, Tobias A1 - Kammler, Martin A1 - Lechner, Alfred T1 - Tunable Nanopillars as Surface Enhanced Raman Scattering (SERS) Active Structure for Optical Quartz Glass Fiber T2 - SMSI 2021 - Sensors and Instrumentation N2 - In this work, a simple cost effective method to create tunable self-assembled three-dimensional nanostructure array-like nanoantennas on a tip of an optical quartz glass fiber is described. The structures are prepared using lithography-less dry etching. Gold nanoparticles are used as an etching mask using a thin metal-film thermal dewetting technique. The structures are applied as sensor for label-free analysis of organic substances in ppb range, such as drug residues in groundwater. The measurements are carried out by means of a Surface-enhanced Raman scattering (SERS) effect, an exchangeable sensor head, and a portable Raman device. This method allows in situ applications. Parathiocresol is used as a model substance to characterize the SERS cells. For metallization, gold and silver are compared. Reproducible SERS enhancement factors up to 10 7 are evaluated. Y1 - 2021 SN - 978-3-9819376-4-0 U6 - https://doi.org/10.5162/SMSI2021/B8.2 SP - 153 EP - 154 PB - AMA Association for Sensors and Measurement ER - TY - GEN A1 - van der Weerd, Bastiaan A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - A Conductivity Probe for Determination of the Carbon Dioxide Tension at the Oxygenator Exhaust Outlet during Extracorporeal Membrane Oxygenation (ECMO) T2 - Proceedings of the 9th ISC Modern Analytical Chemistry 2013, Prag Y1 - 2013 UR - https://www.gdch.de/fileadmin/downloads/Veranstaltungen/Tagungen/2014_Tagungen/analytica/poster_abstracts/sens03_vanderweerd_5860.pdf ER - TY - GEN A1 - Rück, Thomas A1 - Hofmann, Matthias A1 - Bierl, Rudolf T1 - Development of a miniaturized photoacoustic multigas sensing system for trace gas measurement T2 - 17th International Conference on Photoacoustic and Photothermal Phenomena, Oct. 20-24, 2013, Suzhou China Y1 - 2013 UR - https://www.gdch.de/fileadmin/downloads/Veranstaltungen/Tagungen/2014_Tagungen/analytica/poster_abstracts/sens05_rueck_5925.pdf ER - TY - GEN A1 - Rück, Thomas A1 - Matysik, Frank-Michael A1 - Bierl, Rudolf T1 - Development of a miniaturized photoacoustic multigas sensing system for trace gas measurement T2 - analytica conference 2014, 1. bis 4. April, München Y1 - 2014 UR - https://www.gdch.de/fileadmin/downloads/Veranstaltungen/Tagungen/2014_Tagungen/analytica/poster_abstracts/sens05_rueck_5925.pdf ER - TY - GEN A1 - Rück, Thomas A1 - Matysik, Frank-Michael A1 - Bierl, Rudolf T1 - Comparison of acoustic detectors for use in miniaturized photoacoustic devices designed for nitrogen dioxide trace gas measurement T2 - ANAKON, 23.-26.3.2015, Graz Y1 - 2015 ER - TY - JOUR A1 - Pangerl, Jonas A1 - Sukul, Pritam A1 - Rück, Thomas A1 - Fuchs, Patricia A1 - Weigl, Stefan A1 - Miekisch, Wolfram A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone JF - Photoacoustics N2 - n this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) – providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 8.3 ppbV and an NNEA of 1.4E-9 Wcm 1Hz 0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field. KW - Photoacoustic spectroscopy KW - Real-time mass-spectrometry KW - Breath analysis KW - Acetone KW - UV-LED Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-71279 SN - 2213-5979 N1 - Corresponding author der OTH Regensburg: Jonas Pangerl VL - 38 PB - Elsevier ER -