TY - JOUR A1 - Lenich, Andreas A1 - Bachmeier, S. A1 - Dendorfer, Sebastian A1 - Mayr, E. A1 - Nerlich, Michael A1 - Füchtmeier, Bernd T1 - Development of a test system to analyze different hip fracture osteosyntheses under simulated walking JF - Biomedizinische Technik. Biomedical engineering N2 - The mechanical complications of osteosyntheses after hip fractures are previously investigated by mostly static or dynamic uniaxial loading test systems. However, the physiologic loading of the hip joint during a normal gait is a multiplanar, dynamic movement. Therefore, we constructed a system to test osteosyntheses for hip fractures under physiologic multiplanar loading representative of normal gait. To evaluate the testing system, 12 femora pairs were tested under 25,000 cycles with two standard osteosyntheses (Proximal Femoral Nail Antirotation/Gamma3 Nail). For angular movement, the varus collapse to cut out (∝CO) (∝CO=4.8°±2.1° for blade and ∝CO=7.8°±3.8° for screw) was the dominant failure mode, and only slight rotational angle shifts (∝Rot) (∝Rot=1.7°±0.4° for blade and ∝Rot=2.4°±0.3° for screw) of the femoral head around the implant axis were observed. Angular displacements in varus direction and rotation were higher in specimens reinforced with screws. Hence, the cut out model and the migration directions showed a distinction between helical blade and hip screw. However, there were no significant differences between the different implants. The new setup is able to create clinical failures and allows to give evidence about the anchorage stability of different implant types under dynamic gait motion pattern. KW - biomechanical implant test KW - dynamic multiplanar loading KW - hip fractureg KW - implant migration KW - patient specific loading KW - Hüftgelenk KW - Knochenbruch KW - Osteosynthese KW - Bewegungsanalyse KW - Simulation Y1 - 2012 U6 - https://doi.org/10.1515/bmt-2011-0999 VL - 57 IS - 2 SP - 113 EP - 119 ER - TY - JOUR A1 - Wong, Christian A1 - Rasmussen, John A1 - Simonsen, Erik B. A1 - Hansen, Lone A1 - de Zee, Mark A1 - Dendorfer, Sebastian T1 - The Influence of Muscle Forces on the Stress Distribution in the Lumbar Spine JF - The Open Spine Journal N2 - Introduction: Previous studies of bone stresses in the human lumbar spine have relied on simplified models when modeling the spinal musculature, even though muscle forces are likely major contributors to the stresses in the vertebral bones. Detailed musculoskeletal spine models have recently become available and show good correlation with experimental findings. A combined inverse dynamics and finite element analysis study was conducted in the lumbar spine to investigate the effects of muscle forces on a detailed musculoskeletal finite element model of the 4th lumbar vertebral body. Materials and Methodology: The muscle forces were computed with a detailed and validated inverse dynamics musculoskeletal spine model in a lifting situation, and were then applied to an orthotropic finite element model of the 4th lumbar vertebra. The results were compared with those from a simplified load case without muscles. Results: In general the von Mises stress was larger by 30%, and even higher when looking at the von Mises stress distribution in the superio-anterior and central part of the vertebral body and in the pedicles. Conclusion: The application of spine muscles to a finite element model showed markedly larger von Mises stress responses in the central and anterior part of the vertebral body, which can be tolerated in the young and healthy spine, but it would increase the risk of compression fractures in the elderly, osteoporotic spine. KW - Lumbar spine KW - Muscle influence KW - Inverse dynamics KW - Finite element analysis KW - Lendenwirbelsäule KW - Muskelkraft KW - Belastung KW - Finite-Elemente-Methode Y1 - 2011 U6 - https://doi.org/10.2174/1876532701103010021 VL - 3 IS - 1 SP - 21 EP - 26 ER - TY - JOUR A1 - Penzkofer, Rainer A1 - Barnsteiner, K. A1 - Dendorfer, Sebastian T1 - The influence of age, shoe type and kicking direction on the severity of head trauma JF - Journal of Forensic Biomechanics N2 - In the last few years, increasingly kicks to the head were observed as a criminal offense. This study examined the influence of age, shoe type and kicking direction on the severity of head trauma. Male test persons were divided into two groups “Old” and “Young”. Both groups were equipped with light sneakers and combat boots. A standard laboratory crash dummy was used to simulate the victim’s body. First, the dummy’s head, free floating above the ground, was kicked vertically. Second, the dummy’s head was kicked horizontally. Established injury criteria were used to quantify the injury risk. No influence concerning the type of foot wear and no difference between the groups “Old” and “Young” could be found. For all analyses, kicking vertically generally lead to a higher risk for the subject compared to kicking horizontally. In this study, only the integral effect of the kicks could be analyzed. A detailed injury pattern cannot directly be derived from the data. Nevertheless, the presented data show the massive potential of injuries associated with head kicks. KW - Head trauma KW - Biomechanics KW - Kicks KW - Kopfverletzung KW - Schädel-Hirn-Trauma KW - Einflussgröße Y1 - 2014 UR - https://www.longdom.org/open-access/the-influence-of-age-shoe-type-and-kicking-direction-on-the-severity-of-head-trauma-2090-2697-1000116.pdf U6 - https://doi.org/10.4172/2090-2697.1000116 VL - 5 IS - 1 ER - TY - JOUR A1 - Roldán, J.C. A1 - Moralis, A. A1 - Dendorfer, Sebastian A1 - Witte, J. A1 - Reicheneder, C. T1 - Controlled central advancement of the midface after Le Fort III osteotomy by a 3-point skeletal anchorage JF - The Journal of craniofacial surgery N2 - A 3-point skeletal anchorage with taping screws for distraction osteogenesis after a Le Fort III osteotomy was applied for the first time in a severely mentally impaired patient where intraoral devices had to be avoided. All 3-force application points included the center of resistance, which allowed an optimal control on the resulting moment. A novel device for skeletal long-term retention into the nasal dorsum prevented a relapse, whereas adjustment of the midface position was observed. Fusioned three-dimensional computed tomography analysis revealed real movements not accessible by a conventional cephalometry. KW - Mund-Kiefer-Gesichts-Chirurgie KW - Le Fort III KW - distraction KW - vector KW - anchorage KW - three-dimensional computed tomography analysis KW - Distraktion KW - Knochenbildung KW - Osteotomie KW - Dreidimensionale Bildverarbeitung KW - Computertomografie Y1 - 2011 U6 - https://doi.org/10.1097/SCS.0b013e318231fc8d VL - 22 IS - 6 SP - 2384 EP - 2386 ER - TY - JOUR A1 - Renkawitz, Tobias A1 - Dendorfer, Sebastian T1 - Orthopedic navigation technology and biomechanical evaluation for total hip replacement JF - Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine KW - Hüftgelenkprothese KW - Orthopädische Chirurgie KW - Computerunterstütztes Verfahren KW - Biomechanische Analyse Y1 - 2012 U6 - https://doi.org/10.1177/0954411912458746 VL - 226 IS - 12 SP - 897 EP - 898 ER - TY - JOUR A1 - Dendorfer, Sebastian A1 - Hammer, Joachim A1 - Lenich, Andreas T1 - Characterisation and testing of biomaterials JF - Technology and Health Care KW - Testing biomaterials KW - Characterisation testing KW - Biomaterial KW - Test Y1 - 2011 U6 - https://doi.org/10.3233/THC-2011-0644 VL - 19 IS - 5 SP - 357 EP - 371 ER - TY - JOUR A1 - De Pieri, Enrico A1 - Atzori, Federica A1 - Ferguson, Stephen J. A1 - Dendorfer, Sebastian A1 - Leunig, Michael A1 - Aepli, Martin T1 - Contact force path in total hip arthroplasty: effect of cup medialisation in a whole-body simulation JF - HIP International N2 - Background: Cup medialisation down to the true acetabular floor in total hip arthroplasty with a compensatory femoral offset increase seems to be mechanically advantageous for the abductor muscles due to the relocation of the lever arms (body weight lever arm decreased, abductor lever arm increased). However, limited information is currently available about the effects of this reconstruction type at the head cup interface, compared to an anatomical reconstruction that maintains the natural lever arms. Through a whole-body simulation analysis, we compared medialised versus anatomical reconstruction in THA to analyse the effects on: (1) contact force magnitude at the head cup interface; (2) contact force path in the cup; and (3) abductor activity. Methods: Musculoskeletal simulations were performed to calculate the above-mentioned parameters using inverse dynamics analysis. The differences between the virtually implanted THAs were calculated to compare the medialised versus anatomical reconstruction. Results: Cup medialisation with compensatory femoral offset increase led to: (1) a reduction in contact force magnitude at the head cup interface up to 6.6%; (2) a similar contact force path in the cup in terms of sliding distance and aspect ratio; and (3) a reduction in abductor activity up to 17.2% (gluteus medius). Conclusions: In our opinion, these potential biomechanical gains do not generally justify a fully medialised reconstruction, especially in younger patients that are more likely to undergo revision surgery in their lifetime. Cup medialisation should be performed until sufficient press fit and bony coverage of a properly sized and oriented cup can be achieved. KW - Cup medialisation KW - femoral offset KW - hip contact force KW - total hip anthroplasty KW - total hip replacement KW - Hüftgelenkprothese KW - Kontaktkraft KW - Biomechanische Analyse KW - Simulation Y1 - 2020 U6 - https://doi.org/10.1177/1120700020917321 VL - 31 IS - 5 SP - 624 EP - 631 PB - Sage ER - TY - JOUR A1 - Aurbach, Maximilian A1 - Spicka, Jan A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Evaluation of musculoskeletal modelling parameters of the shoulder complex during humeral abduction above 90° JF - Journal of Biomechanics N2 - Based on electromyographic data and force measurements within the shoulder joint, there is an indication that muscle and resulting joint reaction forces keep increasing over an abduction angle of 90°. In inverse dynamics models, no single parameter could be attributed to simulate this force behaviour accordingly. The aim of this work is to implement kinematic, kinetic and muscle model modifications to an existing model of the shoulder (AnyBody™) and assess their single and combined effects during abduction up to 140° humeral elevation. The kinematics and the EMG activity of 10 test subjects were measured during humeral abduction. Six modifications were implemented in the model: alternative wrapping of the virtual deltoid muscle elements, utilization of a three element Hill model, strength scaling, motion capture driven clavicle elevation/protraction, translation of the GH joint in dependency of the acting forces and an alteration of the scapula/clavicle rhythm. From the six modifications, 16 different combinations were considered. Parameter combinations with the Hill model changed the resultant GH joint reaction force and led to an increase in force during abduction of the humerus above 90°. Under the premise of muscle activities and forces within the GH joint rising after 90° of humeral abduction, we propose that the Hill type muscle model is a crucial parameter for accurately modelling the shoulder. Furthermore, the outcome of this study indicates that the Hill model induces the co-contraction of the muscles of the shoulder without the need of an additional stability criterion for an inverse dynamics approach. KW - Shoulder joint KW - Musculoskeletal modelling KW - EMG KW - Glenohumeral joint reaction force KW - Muscle model KW - Schultergelenk KW - Bewegungsapparat KW - Biomechanik KW - Simulation Y1 - 2020 U6 - https://doi.org/10.1016/j.jbiomech.2020.109817 VL - 106 IS - June PB - Elsevier ER - TY - JOUR A1 - Dendorfer, Sebastian A1 - Maier, Hans Jürgen A1 - Taylor, David A1 - Hammer, Joachim T1 - Anisotropy of the fatigue behaviour of cancellous bone JF - Journal of Biomechanics N2 - The fatigue behaviour of materials is of particular interest for the failure prediction of materials and structures exposed to cyclic loading. For trabecular bone structures only a few sets of lifetime data have been reported in the literature and structural measures are commonly not considered. The influence of load contributions which are not aligned with the main physiological axis remains unclear. Furthermore site and species dependent relationships are not well described. In this study five different groups of trabecular bone, defined in terms of orientation, species and site were exposed to cyclic compression. In total, 108 fatigue tests were analysed. The lifetimes were found to decrease drastically when off-axis loads were applied. Additionally, species and site strongly affect fatigue lifetimes. Strains at failure were also found to be a function of orientation. KW - Ermüdung KW - Knochen KW - Spongiosa KW - Anisotropie Y1 - 2008 U6 - https://doi.org/10.1016/j.jbiomech.2007.09.037 VL - 41 IS - 3 SP - 636 EP - 641 ER - TY - GEN ED - Hammer, Joachim ED - Nerlich, Michael ED - Dendorfer, Sebastian T1 - Medicine Meets Engineering: Proceedings of the 2nd Conference on Applied Biomechanics Regensburg N2 - Biomedical Engineering is defined as the science that integrates medical and engineering sciences to improve diagnosis and treatment of patients. Only by this integration progress can be achieved. Both medical and engineering sciences comprise a huge diversity in topics, so it is imaginable that Biomedical Engineering, combining these two science areas, is even more huge. Thanks to this megadisciplinary approach many breakthroughs can be achieved. More and more research groups realize this and start new research projects, which results in a rapid increase in knowledge in Biomedical Engineering. This will only benefit the main goal of Biomedical Engineering; improving diagnosis and treatment of patients when it is spread and applied. The 2nd Regensburg Applied Biomechanics conference is special in that it realized both the distribution of new knowledge and the essential integration of medical and engineering specialists. The conference dealt with the latest results in applied biomechanics, ranging from fundamental bone strength properties via bone remodeling phenomena to new implants that replace lost human functions. Also new research areas like robot surgery and tissue engineering were discussed. KW - Biomechanik Y1 - 2008 SN - 978-1586038281 PB - IOS Press, US ET - 1. Aufl. ER - TY - CHAP A1 - Dendorfer, Sebastian A1 - Hammer, Joachim A1 - Lenich, Andreas ED - Lee, T. Clive ED - Niederer, Peter F. T1 - Characterisation and testing of biomaterials T2 - Basic Engineering for Medics and Biologists: An ESEM Primer KW - Biomaterial KW - Werkstoff KW - Test Y1 - 2010 SN - 978-1607505266 IS - Chapter IV.4. PB - Non Basic Stock Line ER -