TY - JOUR A1 - Schaeffer, Leon A1 - Herrmann, David A1 - Schratzenstaller, Thomas A1 - Dendorfer, Sebastian A1 - Böhm, Valter T1 - Preliminary theoretical considerations on the stiffness characteristics of a tensegrity joint for the use in dynamic orthoses JF - Journal of Medical Robotics Research N2 - Early motion therapy plays an important role for effective long-term healing of joint injuries. In many cases, conventional dynamic orthoses fail to address the intricate movement possibilities of the underlying joints, limited by their simplistic joint representations, often represented by revolute joints, enabling rotations by only one axis. In this paper, a two-dimensional compliant tensegrity joint for use in biomedical applications is investigated. It consists of two compressed members and five compliant tensioned members. Relative movement possibilities are realized by the intrinsic compliance of the structure. In the development of these systems, the first step is the determination of the static stable equilibrium. This analysis is conducted in this paper by considering the potential energy approach or by using the geometric nonlinear finite element method. The mechanical behavior of the structure is assessed with a specific emphasis on its mechanical compliance. The primary objective of this study is the investigation of the influence of structural parameters on the overall stiffness and movability of the structure. The results underscore the significant effect of member parameters on the stiffness and movability of the compliant tensegrity joint, particularly under varying load magnitudes. These findings provide insights for optimizing the joint’s performance, contributing to its potential application in advanced orthotic and exoskeleton devices. KW - mechanical compliance KW - flexibility ellipsis KW - form-finding KW - tensegrity joint Y1 - 2023 U6 - https://doi.org/10.1142/S2424905X23400081 PB - World Scientific ER - TY - JOUR A1 - Schaeffer, Leon A1 - Herrmann, David A1 - Schratzenstaller, Thomas A1 - Dendorfer, Sebastian A1 - Böhm, Valter T1 - Theoretical considerations on stiffness characteristics of a 3-dimensional tensegrity joint model for the use in dynamic hand orthoses JF - Journal of Medical Robotics Research Y1 - 2025 U6 - https://doi.org/10.1142/S2424905X25400069 PB - World Scientific ER - TY - JOUR A1 - Schecklmann, Martin A1 - Schmausser, Maximilian A1 - Klinger, Felix A1 - Kreuzer, Peter M. A1 - Krenkel, Lars A1 - Langguth, Berthold T1 - Resting motor threshold and magnetic field output of the figure-of-8 and the double-cone coil JF - scientific reports N2 - The use of the double-cone (DC) coil in transcranial magnetic stimulation (TMS) is promoted with the notion that the DC coil enables stimulation of deeper brain areas in contrast to conventional figure-of-8 (Fo8) coils. However, systematic comparisons of these two coil types with respect to the spatial distribution of the magnetic field output and also to the induced activity in superficial and deeper brain areas are limited. Resting motor thresholds of the left and right first dorsal interosseous (FDI) and tibialis anterior (TA) were determined with the DC and the Fo8 coil in 17 healthy subjects. Coils were orientated over the corresponding motor area in an angle of 45 degrees for the hand area with the handle pointing in posterior direction and in medio-lateral direction for the leg area. Physical measurements were done with an automatic gantry table using a Gaussmeter. Resting motor threshold was higher for the leg area in contrast to the hand area and for the Fo8 in contrast to the DC coil. Muscle by coil interaction was also significant providing higher differences between leg and hand area for the Fo8 (about 27%) in contrast to the DC coil (about 15%). Magnetic field strength was higher for the DC coil in contrast to the Fo8 coil. The DC coil produces a higher magnetic field with higher depth of penetration than the figure of eight coil. KW - ANTERIOR CINGULATE CORTEX KW - CONNECTIVITY KW - Depression KW - FRONTAL-CORTEX KW - PREDICTOR KW - RTMS KW - STIMULATION KW - TMS Y1 - 2020 U6 - https://doi.org/10.1038/s41598-020-58034-2 VL - 10 IS - 1 PB - Nature ER - TY - JOUR A1 - Scheer, Clara A1 - Kubowitsch, Simone A1 - Dendorfer, Sebastian A1 - Jansen, Petra T1 - Happy Enough to Relax? How Positive and Negative Emotions Activate Different Muscular Regions in the Back - an Explorative Study JF - Frontiers in Psychology N2 - Embodiment theories have proposed a reciprocal relationship between emotional state and bodily reactions. Besides large body postures, recent studies have found emotions to affect rather subtle bodily expressions, such as slumped or upright sitting posture. This study investigated back muscle activity as an indication of an effect of positive and negative emotions on the sitting position. The electromyography (EMG) activity of six back muscles was recorded in 31 healthy subjects during exposure to positive and negative affective pictures. A resting period was used as a control condition. Increased muscle activity patterns in the back were found during the exposure to negative emotional stimuli, which was mainly measured in the lumbar and thorax regions. The positive emotion condition caused no elevated activity. The findings show that negative emotions lead to increased differential muscle activity in the back and thus corroborate those of previous research that emotion affects subtle bodily expressions. KW - electromyography KW - muscle activity KW - emotion KW - sadness KW - happiness KW - embodiment Y1 - 2021 U6 - https://doi.org/10.3389/fpsyg.2021.511746 SN - 1664-1078 VL - Volume 12 IS - May 2021 PB - Frontiers Media ER - TY - JOUR A1 - Schmidt, Ulf A1 - Penzkofer, Rainer A1 - Bachmaier, Samuel A1 - Augat, Peter T1 - Implant Material and Design Alter Construct Stiffness in Distal Femur Locking Plate Fixation: A Pilot Study JF - Clinical Orthopaedics and Related Research® N2 - BACKGROUND: Construct stiffness affects healing of bones fixed with locking plates. However, variable construct stiffness reported in the literature may be attributable to differing test configurations and direct comparisons may clarify these differences. QUESTIONS/PURPOSES: We therefore asked whether different distal femur locking plate systems and constructs will lead to different (1) axial and rotational stiffness and (2) fatigue under cyclic loading. METHODS: We investigated four plate systems for distal femur fixation (AxSOS, LCP, PERI-LOC, POLYAX) of differing designs and materials using bone substitutes in a distal femur fracture model (OTA/AO 33-A3). We created six constructs of each of the four plating systems. Stiffness under static and cyclic loading and fatigue under cyclic loading were measured. RESULTS: Mean construct stiffness under axial loading was highest for AxSOS (100.8 N/mm) followed by PERI-LOC (80.8 N/mm) and LCP (62.6 N/mm). POLYAX construct stiffness testing showed the lowest stiffness (51.7 N/mm) with 50% stiffness of AxSOS construct testing. Mean construct stiffness under torsional loading was similar in the group of AxSOS and PERI-LOC (3.40 Nm/degree versus 3.15 Nm/degree) and in the group of LCP and POLYAX (2.63 Nm/degree versus 2.56 Nm/degree). The fourth load level of > 75,000 cycles was reached by three of six AxSOS, three of six POLYAX, and two of six PERI-LOC constructs. All others including all LCP constructs failed earlier. CONCLUSIONS: Implant design and material of new-generation distal femur locking plate systems leads to a wide range of differences in construct stiffness. CLINICAL RELEVANCE: Assuming construct stiffness affects fracture healing, these data may influence surgical decision-making in choosing an implant system. Y1 - 2013 U6 - https://doi.org/10.1007/s11999-013-2867-0 VL - 471 IS - 9 SP - 2808 EP - 2814 PB - The Association of Bone and Joint Surgeons ER - TY - JOUR A1 - Schmitz, Paul A1 - Neumann, Christoph Cornelius A1 - Neumann, Carsten A1 - Nerlich, Michael A1 - Dendorfer, Sebastian T1 - Biomechanical analysis of iliac crest loading following cortico-cancellous bone harvesting JF - Journal of Orthopaedic Surgery and Research N2 - Background Iliac crest bone harvesting is a frequently performed surgical procedure widely used to treat bone defects. The objective of this study is to assess the biomechanical quantities related to risk for pelvic fracture after harvesting an autologous bone graft at the anterior iliac crest. Methods Finite element models with a simulated harvest site (sized 15 × 20 mm, 15 × 35 mm, 30 × 20 mm and 30 × 35 mm) in the iliac wing are created. The relevant loading case is when the ipsilateral leg is lifted off the ground. Musculoskeletal analysis is utilized to compute the muscle and joint forces involved in this motion. These forces are used as boundary conditions for the finite element analyses. Bone tissue stress is analyzed. Results Critical stress peaks are located between the anterior superior iliac spine (ASIS) and the anterior edge of the harvest site. Irrespective of the graft size, the iliac wing does not show any significant stress peaks with the harvest site being 20 to 25 mm posterior to the ASIS. The harvest area itself inhibits the distribution of the forces applied on the ASIS to extend to the posterior iliac wing. This leads to a lack of stress posterior to the harvest site. A balanced stress distribution with no stress peaks appears when the bone graft is taken below the iliac crest. Conclusion A harvest site located at least 20 to 25 mm posterior to the ASIS should be preferred to minimize the risk of iliac fatigue fracture. KW - Bone harvesting KW - Autologous bone graft KW - Iliac crest KW - Fatigue fracture KW - Pelvis KW - ASIS KW - FEA KW - Biomechanical investigation KW - Beckenkammknochen KW - Knochenentnahme KW - Spongiosa KW - Biomechanische Analyse Y1 - 2018 U6 - https://doi.org/10.1186/s13018-018-0822-1 VL - 13 IS - 108 SP - 1 EP - 8 PB - Springer Nature ER - TY - CHAP A1 - Seefried, C. A1 - Aurbach, Maximilian A1 - Wyss, C. A1 - Dendorfer, Sebastian T1 - Achilles tendon lengthening alters stresses in the growth plate T2 - International Conference BIOMDLORE, June 28 - 30 2018, Białystok, Poland Y1 - 2018 ER - TY - JOUR A1 - Sellmer, Andreas A1 - Stangl, Hubert A1 - Beyer, Mandy A1 - Grünstein, Elisabeth A1 - Leonhardt, Michel A1 - Pongratz, Herwig A1 - Eichhorn, Emerich A1 - Elz, Sigurd A1 - Striegl, Birgit A1 - Jenei-Lanzl, Zsuzsa A1 - Dove, Stefan A1 - Straub, Rainer H. A1 - Krämer, Oliver H. A1 - Mahboobi, Siavosh T1 - Marbostat-100 Defines a New Class of Potent and Selective Antiinflammatory and Antirheumatic Histone Deacetylase 6 Inhibitors JF - Journal of medicinal chemistry N2 - Epigenetic modifiers of the histone deacetylase (HDAC) family contribute to autoimmunity, cancer, HIV infection, inflammation, and neurodegeneration. Hence, histone deacetylase inhibitors (HDACi), which alter protein acetylation, gene expression patterns, and cell fate decisions, represent promising new drugs for the therapy of these diseases. Whereas pan-HDACi inhibit all 11 Zn2+-dependent histone deacetylases (HDACs) and cause a broad spectrum of side effects, specific inhibitors of histone deacetylase 6 (HDAC6i) are supposed to have less side effects. We present the synthesis and biological evaluation of Marbostats, novel HDAC6i that contain the hydroxamic acid moiety linked to tetrahydro-β-carboline derivatives. Our lead compound Marbostat-100 is a more potent and more selective HDAC6i than previously established well-characterized compounds in vitro as well as in cells. Moreover, Marbostat-100 is well tolerated by mice and effective against collagen type II induced arthritis. Thus, Marbostat-100 represents a most selective known HDAC6i and the possibility for clinical evaluation of a HDAC isoform-specific drug. KW - Animals KW - anti-Inflammatory agent KW - chemical synthesis KW - pharmacology KW - therapeutic use KW - toxicity Y1 - 2018 U6 - https://doi.org/10.1021/acs.jmedchem.7b01593 VL - 61 IS - 8 SP - 3454 EP - 3477 PB - ACS Publications ER - TY - CHAP A1 - Siegl, Marco A1 - Rieger, David A1 - Kovárík, Tomáš A1 - Ehrlich, Ingo T1 - Long-Term Behavior of Thermoplastics under UV Light tested by a self-build Device T2 - 3. OTH-Clusterkonferenz, 13. April 2018, Weiden, Tagungsband; Festschrift, 5 Jahre OTH-Verbund N2 - This article presents first results of artificial aging experi-ments by ultraviolet (UV) irradiation on thermoplasticmaterials conducted as an intent of the research project Thermoplastic Composite Structures (TheCoS) in colla-boration of the Ostbayerische Technische Hochschule(OTH) Regensburg and the University of West Bohemia(UWB) in Pilsen as part of a cross-border cooperation. In technical applications, thermoplastic materials are oftenaffected by aging and a related deterioration of the mechanical properties. Therefore, it is necessary to identifythe aging behavior of thermoplastic materials. For this,experiments were performed for three thermoplasticmaterials, namely polypropylene (PP), ultra high mole -cular weight polyethylene (UHMWPE) and high impactstrength polystyrene (HIPS). For these experiments, a UV chamber was constructed according to the internationalstandard EN ISO 4892-3 for simulation of exposurebehind window glass. The results are evaluated by testing the flexural strength and the dynamic mechanicalresponse after a selected period of time under UV lightand then compared to untreated test specimens. Y1 - 2018 UR - https://www.oth-regensburg.de/fileadmin/media/forschung/Dateien_2018/Clusterkonferenz-Tagungsband-2018.pdf SP - 118 EP - 122 ER - TY - GEN A1 - Singh, Max Diamond T1 - Reclassification of Orthopedic Devices per the Medical Device Regulation T2 - OSMA Winter Educational Program, St. Petersburg/USA, 2019. - [Veranstalter: Orthopedic Surgical Manufacturers Association (OSMA)] Y1 - 2019 ER - TY - GEN A1 - Singh, Max Diamond T1 - European Union MDRs impact on device manufacturers: Reprocessing of surgical invasive devices, critical timeliness and technical documentation requirements under MDR BT - [Vortrag gehalten am 26.03.2019] T2 - The validation of sterile medical devices: sterilization, packaging, biocompatibility, toxicology and reprocessing, Amsterdam, 26.03. - 28.03.2019 [Veranstalter: Nelson Labs ; Sterigenics] Y1 - 2019 ER - TY - GEN A1 - Singh, Max Diamond T1 - Challenges to innovate in the medical device industry under the light of the new EU MDR : a notified body perspective BT - Keynote Presentation. - Amsterdam, 21.-22.11.2019 // [Veranstalter: Samtek Group] T2 - Intelligent medical devices - the next disruptor in healthcare ; challenges and oppoertunieties: technical, clinical, regulatory and health economics/market access Y1 - 2019 ER - TY - GEN A1 - Singh, Max Diamond T1 - Innovation challenges for orthopedic device manufacturers under the new EU MDR BT - a notified body perspective T2 - ORS (Orthopaedic Research Society) Annual Meeting. - Phoenix, Arizona, 08. - 11.02.2020 Y1 - 2020 ER - TY - GEN A1 - Singh, Max Diamond T1 - EU-MDR from a Notified Body Perspective - aktuelle Situation hinsichtlich der Anforderungen zum Lieferantenmanagement BT - Tuttlingen, Technology Mountains / Medical Mountains, 2019 Y1 - 2019 ER - TY - GEN A1 - Singh, Max Diamond T1 - EU Medical Device Regulation: Top Challenges of Orthopedic Manufacturers T2 - OMTEC 2019 : 15th Annual Orthopedic Manufacturing & Technology Exposition and Conference, Chicago, 11.6.2019 Y1 - 2019 ER - TY - GEN A1 - Singh, Max Diamond T1 - KARL STORZ Navigation Panel Unit - Navigation for ENT surgery T2 - FESS 2010 : International Workshop on FESS ; Lectures & Live Surgery. - Royal Pearl Hospital, Tiruchirappalli (Indien), 10.-11.04.2010 Y1 - 2010 ER - TY - GEN A1 - Singh, Max Diamond T1 - Conformity Assessment Procedure MDR BT - [Vortrag gehalten am 24.02.2020] T2 - MDR Training: Person Responsible for Regulatory Compliance Course, 24.-25.02.2020, Tel Aviv, Obelis Academy Y1 - 2020 ER - TY - GEN A1 - Singh, Max Diamond T1 - Innovationsmanagement BT - Sitzung des Ulmer Arbeitskreises Innovationsmanagement, Ulm, 03.11.2011 Y1 - 2011 ER - TY - GEN A1 - Singh, Max Diamond T1 - General Overview of the Medical Device Regulation T2 - MDR-Roadshow - TÜV SÜD MHS, India Y1 - 2020 ER - TY - CHAP A1 - Singh, Max Diamond ED - Schwegel, Philipp ED - Da-Cruz, Patrick ED - Hemel, Ulrich ED - Oberender, Peter T1 - Produktmanagement in der Medizintechnik T2 - Medizinprodukte Management N2 - Das Management in der Medizinprodukteindustrie steht vor vielfältigen Herausforderungen. So sinken einerseits die Produktpreise, anderseits wird auch für die kommenden Jahre in vielen Segmenten ein Mengenwachstum erwartet. Dies stellt die internen Prozesse, vom Customer Service bis hin zur Forschung & Entwicklung, auf den Prüfstand. Die Entscheidungsträger auf Kundenseite verändern sich, weg vom Produktanwender hin zu professionellen Einkaufsgemeinschaften mit immer größerer Verhandlungsmacht. Der hohe Internationalisierungsgrad der Unternehmen führt zu einer steigenden Komplexität bei der Implementierung von Marketing-, Vertriebs- und Produktentwicklungsstrategien auf Länderebene. Darüber hinaus werden zunehmend neue Geschäftsmodelle mit hohem Dienstleistungsanteil entwickelt, die mit der traditionellen Lieferantenrolle wenig zu tun haben und von Managern eine neue Fähigkeiten für die Umsetzung erfordern. Die Autoren des Sammelbands greifen die genannten Herausforderungen auf und bieten mit ihren Beiträgen Lösungsansätze, die sowohl für Manager im Medizinprodukteunternehmen als auch für Wissenschaftler und Studierende relevant sind. Y1 - 2014 SN - 978-3-941678-47-7 SP - 148 EP - 161 PB - PCO-Verlag CY - Bayreuth ER - TY - GEN A1 - Singh, Max Diamond T1 - Managing Innovation from the Notified Body Perspective - Understanding the 3 C’s of EU Regulations to Ensure Product Compliance: Changes, Challenges and Contributions T2 - 3rd annual european medical device and diagnostic product development and management meeting, 12-13 February 2019, Brussels Y1 - 2019 ER - TY - GEN A1 - Singh, Max Diamond T1 - Joint NB-Position Paper on Spinal Classification per the MDR Y1 - 2019 UR - https://www.team-nb.org/wp-content/uploads/2019/01/Joint-NB-Spinal-Classification-Decision-Tree_final.pdf ER - TY - THES A1 - Singh, Max Diamond T1 - Aspects of the Dynamics of Spine Surgery Technologies: Assessing the Reality of Innovation and Entrepreneurship in the U.S. Medical Device Industry Y1 - 2016 PB - Karlsruhe Institute of Technology CY - Karlsruhe ER - TY - GEN A1 - Singh, Max Diamond T1 - MDR - Die neuen rechtlichen Bedingungen für Händler und Hersteller: aus der Sicht einer benannten Stelle T2 - MEGRA Jahrestagung. - Wien, 18.05.2020 [Veranstalter: Mitteleuropäische Gesellschaft für Regulatory Affairs] Y1 - 2020 ER - TY - GEN A1 - Singh, Max Diamond T1 - Medical Device Regulation BT - Kurzer Überblick zur Zulassung von Medizinprodukten T2 - Forum MedTech Pharma: Start-ups in der Medizintechnik: Besonderheiten und Fallbeispiele, München, 17.7.2019 Y1 - 2019 ER - TY - GEN A1 - Singh, Max Diamond T1 - Market Access for Devices under MDD and MDR: Obligations for Manufacturers T2 - OSMA - Orthopedic Surgical Manufacturers Association, Winter Educational Program - virtual Y1 - 2021 ER - TY - GEN A1 - Singh, Max Diamond T1 - Herausforderungen der Medizinprodukteindustrie bei der Internationalisierung T2 - Studienwoche an der HNU (Hochschule Neu-Ulm) 2020 Y1 - 2020 ER - TY - GEN A1 - Singh, Max Diamond T1 - Zusätzliche Anforderungen an Produktdaten und technische Dokumentation durch die MDR T2 - Medizintechnik Kongress 2018: Effizienz in der Medizinprodukteentwicklung vor dem Hintergrund von MDR und IVDR ; Frankfurt am Main, 08.11.2018, [Veranstalter: Velten Consulting & ILC Consulting] Y1 - 2018 ER - TY - GEN A1 - Singh, Max Diamond T1 - MDR Implementation Status and Lessons Learned from the Past Months: A Notified Body Perspective T2 - Cambridge Healthtech Institute's 2nd Annual Medical Device Clinical Trial Design and Operations: Trial Design and Technology to Optimize Medical Device Trials, Orlando, Florida + Virtual, 02.-03.03.2021 Y1 - PB - Cambridge Innovation Institute ER - TY - GEN A1 - Singh, Max Diamond T1 - MDR implementation status & lessons learned BT - MDR-Audtis – Best Practive & Learning, Tuttlingen, 10.02.2021 Y1 - 2021 ER - TY - JOUR A1 - Singh, Max Diamond T1 - Orthopedic Medical Devices Under The Scope of The EU MDR JF - MedTech Outlook Y1 - 2019 UR - https://embedded-solutions.medicaltechoutlook.com/cxoinsight/orthopedic-medical-devices-under-the-scope-of-the-eu-mdr-nwid-921.html ER - TY - GEN A1 - Singh, Max Diamond T1 - Stakeholder view on Post Market Surveillance under the EU MDR: Timelines, Compliance and Requirements ; Post Market Surveillance & Vigilance BT - [Vortrag gehalten am: 23.6.2020] T2 - MedTech summit 2020: EU MDR & IVDR: the end ist in sight, 22.-26.06.2020, Dublin/virtual Y1 - 2020 ER - TY - GEN A1 - Singh, Max Diamond T1 - Quality in Medical Device Innovation for Start-ups, SME, and large enterprises through the new Medical Device Regulation T2 - 3rd European QA Conference, Dublin, 06. - 08.11.2019 Y1 - 2019 ER - TY - GEN A1 - Singh, Max Diamond T1 - Notified body feedback: PSUR Forms. Post Market Surveillance & Vigilance BT - [Vortrag gehalten am 24.06.2020] T2 - MedTech Summit 2020: EU MDR & IVDR: the end is in sight, Dublin/virtual, 20.-26.06.2020 Y1 - 2020 ER - TY - GEN A1 - Singh, Max Diamond T1 - Technical Documentation MDR / IVDR, including the Declaration of Conformity BT - [Vortrag gehalten am 24.02.2020] T2 - MDR Training: Person Responsible for Regulatory Compliance, 24.-25.02.2020, Tel Aviv, Obelis Academy Y1 - 2020 ER - TY - GEN A1 - Singh, Max Diamond T1 - Notified Body Viewpoint : Preparing for MDR/IVDR T2 - MDR/IVDR - Status Report from Stakeholders. Where are we now in November 2018? - Bern, 22.11.2018 - [Veranstalter: RAPS : Regulatory Affairs Professionals Society] Y1 - 2018 ER - TY - GEN A1 - Singh, Max Diamond T1 - Strategies to Navigate to the EU MDR and Clinical Requirements T2 - Regulatory Affairs Professionals Society (RAPS): Session 1 - Tampa, Florida 2019 Y1 - 2019 ER - TY - GEN A1 - Singh, Max Diamond T1 - Technical Aspects for Navigated Sinus Surgery T2 - 4th Workshop on Endoscopic Surgery of the Maxillary Sinus and Navigation, Tübingen University Hospital, 2009 Y1 - 2009 ER - TY - GEN A1 - Singh, Max Diamond T1 - Overview of the Medical Device Regulation (MDR) BT - MDR-Roadshow TÜV SÜD MHS, San Diego & Minneapolis, 2018 Y1 - 2018 ER - TY - CHAP A1 - Singh, Max Diamond A1 - Capanni, Felix ED - Pfannstiel Mario A., ED - Da-Cruz, Patrick ED - Rasche, Christoph T1 - Medizintechnik-Spin-offs aus der Hochschule - Ein Prozessbeispiel T2 - Entrepreneurship im Gesundheitswesen II N2 - Die Aufmerksamkeit für Unternehmensgründungen hat in den letzten Jahren extrem zugenommen. Grundsätzlich muss ein Start-up in einem kompetitiven Umfeld erfolgreich sein, um bestehen zu können. Der Weg dorthin wird maßgeblich beeinflusst durch Planung und finanzielle Ressourcen, die die Gründer bereitstellen müssen. In der Medizinprodukteindustrie kommen zusätzlich große Hürden hinzu, die u. a. einen kurzen Produktlebenszyklus, lange Projektlaufzeiten, aufwendige klinische Studien und aktuell neue gesetzliche Verordnungen betreffen. Dieser Beitrag konzentriert sich zunächst auf mögliche Fördermittel und Beratung von Start-up-Projekten aus dem Hochschulbereich. Aus einer Analyse derzeit existierender Gründerwettbewerbe im Hinblick auf das Gesundheitswesen werden dem Leser entsprechende Adressen zum Einwerben von Fördermitteln geliefert. Darüber hinaus wird ein Pilot-Prozess vorgestellt, wie eine Ausgründungsberatung an der Hochschule Ulm im Studiengang Medizintechnik derzeit verläuft. Dies kann möglicherweise ein Anknüpfungspunkt für eine zukünftige Institutionalisierung von Spin-off-Vorhaben aus dem Hochschulbereich sein. Y1 - 2018 SN - 978-3-658-14781-5 SN - 978-3-658-14780-8 PB - Springer Gabler CY - Wiesbaden ER - TY - JOUR A1 - Singh, Max Diamond A1 - Russ, Jochen A1 - Terzidis, Orestis T1 - The Impact of the ObamaCare Excise Tax on Innovation and Entrepreneurship – Early Empirical Findings JF - International Journal of Innovation Science N2 - This study addresses aspects of governmental influence on innovation by analyzing the impact of the ObamaCare excise tax on the medical device industry. We initially give an overview of common approaches to measuring innovativeness and entrepreneurship, empirically assess whether existing metrics are suitable for investigating the innovation performance of the U.S. medical device industry, and define a new measure (firm innovation activity) for entrepreneurship. Then we perform a quantitative analysis to explore the impact of the tax. We analyze more than 60,000 product clearances from 1996 to 2013, using the FDA database. We find a significant relationship between product counts and revenues for one segment. Contrary to the present criticism of the excise tax, we find hardly any noteworthy response in either firm innovation activity or number of products launched in the year after the tax was introduced. The 2013 reduction of new product submissions is well within the limits of typical annual fluctuations observed in previous years. This provides a first indication that the excise tax act did not have a strong impact on innovative activities through the present. Y1 - 2015 U6 - https://doi.org/10.1260/1757-2223.7.2.75 VL - 7 IS - 2 SP - 75 EP - 90 PB - Emerald ER - TY - GEN A1 - Singh, Max Diamond A1 - Schlagintweit, S. A1 - Reischle, G. T1 - Additive-Manufactured Orthopedic Implants Under MDR Y1 - 2020 UR - https://www.odtmag.com/contents/view_online-exclusives/2020-08-11/additive-manufactured-orthopedic-implants-under-mdr/ IS - 08.11.20 ER - TY - JOUR A1 - Singh, Max Diamond A1 - Terzidis, O. T1 - Introducing Innovation Phase Transition JF - International Journal of Innovation Science N2 - Innovation diffusion points toward how innovations spread into the market after launch. This paper investigates diffusion dynamics at market entry time and proposes a new evolution pattern at the intersection between inventions and innovations. With this in mind, we initially prove that patent filings correlate with new product introductions in the U.S. spine market. Then we test our new theory supposing that certain patent filing threshold numbers accelerate strong economic returns in terms of innovations. We find that firms hitting certain patent filing thresholds significantly increase their product launches in the mentioned market. Moreover, the results seem to indicate that economic returns of inventions may be measured substantially. Thus, this paper suggests a new research area by utilizing our proposed concept about an Innovation Outcome Trigger Value (IOTV). Furthermore, the implications may also be interesting for practitioners, since we empirically prove that inventive activities turn out to be worthwhile, indeed. Y1 - 2015 U6 - https://doi.org/10.1108/IJIS-07-04-2015-B003 SN - 1757-2223 VL - 7 IS - 4 SP - 249 EP - 262 PB - Emerald ER - TY - CHAP A1 - Spreiter, G. A1 - Galibarov, Pavel E. A1 - Dendorfer, Sebastian A1 - Ferguson, Stephen J. T1 - Influence of kyphosis on spinal loading T2 - 10th International Symposium Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) Meeting, 11. - 14. April 2012, Berlin Y1 - 2012 ER - TY - RPRT A1 - Steiger, Tamara A1 - Foltan, Maik A1 - Philipp, Alois A1 - Müller, Thomas A1 - Gruber, Michael A1 - Bredthauer, Andre A1 - Krenkel, Lars A1 - Birkenmaier, Clemens A1 - Lehle, Karla T1 - Accumulations of von Willebrand factor within ECMO oxygenators: Potential indicator of coagulation abnormalities in critically ill patients? N2 - Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots—in particular, the presence of von Willebrand factor (vWF)—may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti‐vWF and anti‐P‐selectin) and counterstained with 4′,6‐diamidino‐2‐phenylindole. The extent of vWF‐loading was correlated with patient and technical data. While 12 MOs showed low vWF‐loadings, 9 MOs showed high vWF‐loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF‐fibers/“cobwebs,” leukocytes, platelet–leukocyte aggregates (PLAs), and P‐selectin‐positive platelet aggregates were independent of the extent of vWF‐loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high‐molecular‐weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy. Y1 - 2019 ER - TY - JOUR A1 - Steiger, Tamara A1 - Foltan, Maik A1 - Philipp, Alois A1 - Müller, Thomas A1 - Gruber, Michael A1 - Bredthauer, Andre A1 - Krenkel, Lars A1 - Birkenmaier, Clemens A1 - Lehle, Karla T1 - Accumulations of von Willebrand factor within ECMO oxygenators: Potential indicator of coagulation abnormalities in critically ill patients? JF - Artificial Organs N2 - Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots-in particular, the presence of von Willebrand factor (vWF)-may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti-vWF and anti-P-selectin) and counterstained with 4 ',6-diamidino-2-phenylindole. The extent of vWF-loading was correlated with patient and technical data. While 12 MOs showed low vWF-loadings, 9 MOs showed high vWF-loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF-fibers/"cobwebs," leukocytes, platelet-leukocyte aggregates (PLAs), and P-selectin-positive platelet aggregates were independent of the extent of vWF-loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high-molecular-weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy. KW - ECMO KW - PLATELET ACTIVATION KW - THROMBOSIS KW - BLOOD FLOW KW - INFLAMMATION Y1 - 2019 U6 - https://doi.org/10.1111/aor.13513 SN - 1525-1594 VL - 43 IS - 11 SP - 1065 EP - 1076 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Stelzer, Vera A1 - Krenkel, Lars T1 - 2D numerical investigations derived from a 3D dragonfly wing captured with a high-resolution micro-CT JF - Technology and health care : official journal of the European Society for Engineering and Medicine N2 - BACKGROUND: Due to their corrugated profile, dragonfly wings have special aerodynamic characteristics during flying and gliding. OBJECTIVE: The aim of this study was to create a realistic 3D model of a dragonfly wing captured with a high-resolution micro-CT. To represent geometry changes in span and chord length and their aerodynamic effects, numerical investigations are carried out at different wing positions. METHODS: The forewing of a Camacinia gigantea was captured using a micro-CT. After the wing was adapted an error-free 3D model resulted. The wing was cut every 5 mm and 2D numerical analyses were conducted in Fluent® 2020 R2 (ANSYS, Inc., Canonsburg, PA, USA). RESULTS: The highest lift coefficient, as well as the highest lift-to-drag ratio, resulted at 0 mm and an angle of attack (AOA) of 5∘. At AOAs of 10∘ or 15∘, the flow around the wing stalled and a Kármán vortex street behind the wing becomes CONCLUSIONS: The velocity is higher on the upper side of the wing compared to the lower side. The pressure acts vice versa. Due to the recirculation zones that are formed in valleys of the corrugation pattern the wing resembles the form of an airfoil. KW - aerodynamics KW - computational fluid dynamics KW - Dragonfly wing KW - gliding flight KW - insect flight Y1 - 2022 U6 - https://doi.org/10.3233/THC-219010 N1 - Corresponding author: Vera Stelzer VL - 30 IS - 1 SP - 283 EP - 289 PB - IOS Press ER - TY - GEN A1 - Stelzer, Vera A1 - Rütten, Markus A1 - Krenkel, Lars T1 - Numerical Investigation of a 3D Dragonfly Wing Captured with a High-Resolution Micro-CT T2 - 8th European Congress on Computational Methods in Applied Sciences and Engineering, ECCOMAS Congress 2022, 5-9 June 2022, Oslo, Norway N2 - The special wing geometry of dragonflies consisting of veins and a membrane forming a corrugated profile leads to special aerodynamic characteristics. To capture the governing flow regimes of a dragonfly wing in detail, a realistic wing model has to be investigated. Therefore, this study aimed to analyze the aerodynamic characteristics of a 3D dragonfly wing reconstructed from a high-resolution micro-CT scan. Afterwards, a spatially high discretized mesh was generated using the mesh generator CENTAUR™ 14.5.0.2 (CentaurSoft, Austin, TX, US) to finally conduct Computational Fluid Dynamics (CFD) investigations in Fluent® 2020 R2 (ANSYS, Inc., Canonsburg, PA, US). Due to the small dimensions of the wing membrane, only the vein structure of a Camacinia Gigantea was captured at a micro-CT voxel size of 7 microns. The membrane was adapted and connected to the vein structure using a Boolean union operation. Occurring nconsistencies after combining the veins and the membrane were corrected using an adapted pymesh script [1]. As an initial study, only one quarter of the wing (outer wing section) was investigated to reduce the required computational effort. The resulting hybrid mesh consisting of 10 pseudo-structured prism layers along the wing surface and tetrahedra in the farfield area has 43 mio. nodes. The flow around the wing was considered to be incompressible and laminar using transient calculations. When the flow passes the vein structures, steady vortices occur in the corrugation valleys leading to recirculation zones. Therefore, the dragonfly wing resembles the profile of an airfoil. This leads to comparable lift coefficients of dragonfly wings and airfoil profiles at significantly reduced structural weight. The reconstructed geometry also included naturally occurring triangular prismlike serrated structures at the leading edge of the wing, which have comparable effects to micro vortex generators and might stabilize the recirculation zones. Further work aims to investigate the aerodynamic properties of a complete dragonfly wing during wing flapping. KW - CFD KW - Dragonfly KW - Aerodynamics KW - Gliding Flight Y1 - 2022 ER - TY - GEN A1 - Stelzer, Vera A1 - Tauwald, Sandra Melina A1 - Vielsmeier, Veronika A1 - Cieplik, Fabian A1 - Kandulski, Arne A1 - Schneider-Brachert, Wulf A1 - Wuensch, Olaf A1 - Rütten, Markus A1 - Krenkel, Lars T1 - Generation, Distribution, and Contagiousness of Surgical Smoke during Tracheotomies T2 - 23. DGLR Fach-Symposium Strömungen mit Ablösung, 09./10. November 2022, Berlin, Deutschland N2 - Surgical smoke has been a little discussed topic in the context of the current pandemic. Surgical smoke is generated during the cauterization of tissue with heat-generating devices and consists of 95% water vapor and 5% cellular debris in the form of particulate matter. In-vivo investigations are performed during tracheotomies where surgical smoke is produced during tissue electrocautery. Furthermore, in-vitro parametric studies to investigate the particle number and size distribution and the spatial distribution of surgical smoke with laser light sheet technique are conducted. The higher the power of the high-frequency-device the larger the particles in size and the higher the resulting particle counts. The images taken show the densest smoke at 40W with artificial saliva. The resulting characteristic size distribution, which may include viruses and bacterial components, confirms that the risk arising from surgical smoke should be considered. Furthermore, the experiments will provide the database for further numerical investigations. Y1 - 2022 UR - https://www.dlr.de/as/Portaldata/5/Resources/dokumente/veranstaltungen/stab_workshop/Jahresbericht2022.pdf CY - Göttingen ER - TY - CHAP A1 - Stelzer, Vera A1 - Tauwald, Sandra Melina A1 - Vielsmeier, Veronika A1 - Cieplik, Fabian A1 - Kandulski, Arne A1 - Schneider-Brachert, Wulf A1 - Wünsch, Olaf A1 - Rütten, Markus A1 - Krenkel, Lars ED - Dillman, Andreas ED - Heller, Gerd ED - Kraemer, Ewald ED - Wagner, Claus ED - Weiss, Julien T1 - Generation and Distribution of Surgical Smoke During High Frequency Electrocauterization T2 - New Results in Numerical and Experimental Fluid Mechanics XIV. STAB/DGLR Symposium 2022 N2 - Surgical Smoke is generated during the cauterization of tissue with high-frequency (HF) devices and consists of 95% water vapor and 5% cellular debris. When the coagulation tweezers, which are supplied with HF voltage by the HF device, touch tissue, the electric circuit is closed, and smoke is generated by the heat. In-vivo investigations are performed during tracheotomies where surgical smoke is produced during coagulation of tissue. Furthermore, in-vitro parametric studies to investigate the particle number and size distribution and the spatial distribution of surgical smoke with laser light sheet technique are conducted. With higher power of the HF device, the particles generated are larger in size and the total number of particles generated is also higher. Adding artificial saliva to the tissue shows even higher particle counts. The study by laser light sheet also confirms this. The resulting characteristic size distribution, which may include viruses and bacterial components, confirms considering the risk arising from surgical smoke. Furthermore, the experiments will provide the database for further numerical investigations. KW - Surgical smoke KW - Fluid Mechanics KW - Aerosols KW - Tracheotomies Y1 - 2023 SN - 978-3-031-40481-8 U6 - https://doi.org/10.1007/978-3-031-40482-5_53 SP - 559 EP - 568 PB - Springer Nature Switzerland AG CY - Cham, Switzerland ER - TY - CHAP A1 - Striegl, B. A1 - Kujat, Richard A1 - Dendorfer, Sebastian T1 - Quantitative analysis of cartilage surface by confocal laser scanning microscopy T2 - Biomedizinische Technik Y1 - 2014 U6 - https://doi.org/10.1515/bmt-2014-4012 VL - 59 IS - s1-A SP - 24 ER - TY - CHAP A1 - Suess, Franz A1 - Melzner, Maximilian A1 - Dendorfer, Sebastian T1 - Towards ergonomics working - machine learning algorithms and musculoskeletal modeling T2 - IOP Conference Series: Materials Science and Engineering N2 - Ergonomic workplaces lead to fewer work-related musculoskeletal disorders and thus fewer sick days. There are various guidelines to help avoid harmful situations. However, these recommendations are often rather crude and often neglect the complex interaction of biomechanical loading and psychological stress. This study investigates whether machine learning algorithms can be used to predict mechanical and stress-related muscle activity for a standardized motion. For this purpose, experimental data were collected for trunk movement with and without additional psychological stress. Two different algorithms (XGBoost and TensorFlow) were used to model the experimental data. XGBoost in particular predicted the results very well. By combining it with musculoskeletal models, the method shown here can be used for workplace analysis but also for the development of real-time feedback systems in real workplace environments. Y1 - 2021 U6 - https://doi.org/10.1088/1757-899X/1208/1/012001 SN - 1757-899X N1 - Corresponding author: Sebastian Dendorfer VL - 1208 PB - IOP Publishing ER - TY - GEN A1 - Suess, Franz A1 - Melzner, Maximilian A1 - Dendorfer, Sebastian T1 - Towards Ergonomic working - machine learning algorithms and musculoskeletal modeling T2 - RIM 2021, 13th International Scientific Conference on Manufacturing Engineering, 29 Sept. - 1 Oct 2021, Sarajevo, Bosnia and Herzegovina Y1 - 2021 ER - TY - THES A1 - Süß, Franz T1 - The influence of mental stress on the musculoskeletal human back during static posture and trunk motion N2 - The investigation of the influence of mental stress on muscle recruitment of the back and its effect on the intervertebral discs was the main focus of this work. Furthermore, the goal was to develop algorithms to use mental stress as an input parameter in musculoskeletal simulation models. In the first step, a study was designed to investigate the influence of emotional and cognitive stress without kinetic influencing factors during sitting. At the muscular level, emotional stress was found to affect the upper back, while cognitive stress elicited higher muscle activity in the upper and lower back. Using a newly developed algorithm to apply back muscle recruitment changes to static inverse kinematic simulation models, load increases at the discs of up to 189 N on average and up to 907 N at peak were found.Based on the results of the first study, a second dynamic study was designed and conducted. In this case, the focus was on the cognitive stressor and the lower back. Using a dynamometer, subject-specific loads were applied during extension and flexion of the upper back. In contrast to the first study, in the upper back, only the right m. trapezius pars descendens showed a load-induced difference in muscle activity, but the lower back did. To investigate the effects of muscle tone increase in detail, the algorithm developed in the first study was extended to the dynamic case. The use of simulation models allowed the inference of the effects of the purely stress-induced tone increase. For this purpose, the kinetic and muscular effects were isolated and simulated. The study revealed a stress increase of 47% of the body weight in the L4L5 disc. The final numerical study focused on the general application of muscle activities to inverse kinematic simulation models. This was based on the novel simulation algorithm used in study two and the measured muscle activities. The simulation of the measured muscle activities formed the link between reality and simulation. To simulate the activities, neural networks and gradient boosting regression algorithms were investigated. The latter were found to be better suited to represent the data. However, the data is too small for a detailed statement, especially for loads below 100%. The results of this work can help to better assess the musculoskeletal effects of psychological stress on the musculoskeletal system and, if necessary, to develop ergonomic prevention strategies. By recognizing stress-related kinematic difference, as well as subsequent prompting of trunk movement, could help prevent long-term effects. When examining any situation, the combination of machine learning and musculoskeletal simulation tools can help examine and minimize the effects of psychological stress. N2 - Die Untersuchung des Einflusses von mentalem Stress auf die Muskelrekrutierung des Rückens und dessen Auswirkung auf die Bandscheiben war der Schwerpunkt dieser Arbeit. Des Weiteren war es das Ziel, Algorithmen zu entwickeln, um die mentale Belastung als Eingabeparameter in muskuloskelettalen Simulationsmodellen zu nutzen. Im ersten Schritt wurde eine Studie konzipiert, um den Einfluss von emotionalem und kognitivem Stress ohne kinetische Einflussfaktoren beim Sitzen zu untersuchen. Auf muskulärer Ebene wurde festgestellt, dass emotionaler Stress den oberen Rücken beeinflusste, während kognitiver Stress höhere Muskelaktivität im oberen und unteren Rücken auslöste. Unter Verwendung eines neu entwickelten Algorithmus zur Anwendung von Rekrutierungsänderungen der Rückenmuskulatur auf statische inverse kinematische Simulationsmodelle wurden Belastungserhöhungen an den Bandscheiben von bis zu 189 N im Mittel und bis zu 907 N in der Spitze gefunden. Basierend auf den Ergebnissen der ersten Studie wurde eine zweite dynamische Studie konzipiert und durchgeführt. In diesem Fall lag der Fokus auf dem kognitiven Stressor und dem unteren Rücken. Mit Hilfe eines Dynamometers wurden subjektspezifische Belastungen während der Extension und Flexion des Oberkörpers aufgebracht. Im Gegensatz zur ersten Studie konnte im oberen Rücken, nur im rechten m. trapezius pars descendens ein Lastfall bedingter Unterschied in der Muskelaktivität festgestellt werden, wohl aber im unteren Rücken. Um die Auswirkungen der Muskeltonuserhöhung im Detail zu untersuchen, wurde der in der ersten Studie entwickelte Algorithmus auf den dynamischen Fall erweitert. Die Verwendung von Simulationsmodellen erlaubte den Rückschluss auf die Auswirkungen der rein stressinduzierten Tonuserhöhung. Hierfür wurden die kinetischen und muskulären Effekte isoliert und simuliert. Die Studie ergab eine Belastungserhöhung von 47 % des Körpergewichts in der L4L5 Bandscheibe. Die abschließende numerische Studie konzentrierte sich auf die allgemeine Anwendung von Muskelaktivitäten auf inverse kinematische Simulationsmodelle. Grundlage dafür waren der neuartige Simulationsalgorithmus, der in Studie zwei verwendet wurde, und die gemessenen Muskelaktivitäten. Die Simulation der gemessenen Muskelaktivitäten bildete das Bindeglied zwischen Realität und Simulation. Um die Aktivitäten zu simulieren, wurden neuronale Netze und Gradient-Boosting-Regressionsalgorithmen untersucht. Es zeigte sich, dass letztere besser geeignet sind, die Daten abzubilden. Für eine detaillierte Aussage, insbesondere für Belastungen unter 100 %, ist die Datenlage jedoch zu klein. Die Ergebnisse dieser Arbeit können helfen, die muskuloskelettalen Auswirkungen psychischer Belastungen auf den Bewegungsapparat besser einzuschätzen und ggf. ergonomische Präventionsstrategien zu entwickeln. Durch das Erkennen stressbedingter kinematischer Unterschied sowie die darauffolgende Aufforderung zur Rumpfbewegung könnte helfen, langfristige Auswirkungen zu vermeiden. Bei der Untersuchung beliebiger Situationen, kann die Kombination aus maschinellem Lernen und muskuloskelettalen Simulationswerkzeugen helfen, die Auswirkungen psychischer Belastungen zu untersuchen und zu minimieren. KW - Musculoskeletal simulation KW - mental stress KW - spinal disc loads Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:355-epub-460554 ER - TY - CHAP A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Rasmussen, John A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - The influence of cognitive stress on muscle activation and spinal disc load T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - CHAP A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - Investigation of cognitive stress induced changes in spinal disc forces due to altered kinematics and muscle activity T2 - World Congress Biomechanics, Dublin, 2018 Y1 - 2018 ER - TY - CHAP A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - The influence of mental stress on spinal disc loading and muscle activity T2 - 23th Congress of the European Society of Biomechanics, Sevilla, Spain, 2017 Y1 - 2017 ER - TY - CHAP A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - The influence of stress on spinal loading T2 - ESEM webconference, Dez. 2017 Y1 - 2016 ER - TY - CHAP A1 - Süß, Franz A1 - Putzer, Michael A1 - Dendorfer, Sebastian T1 - Numerische und experimentelle Untersuchungen an der Wirbelsäule T2 - Forschungssymposium Bad Abbach, Germany, 2015 Y1 - 2015 ER - TY - JOUR A1 - Tauwald, Sandra Melina A1 - Erzinger, Florian A1 - Quadrio, Maurizio A1 - Rütten, Markus A1 - Stemmer, Christian A1 - Krenkel, Lars T1 - Tomo-PIV in a patient-specific model of human nasal cavities: a methodological approach JF - Measurement Science and Technology N2 - The human nose serves as the primary gateway for air entering the respiratory system and plays a vital role in breathing. Nasal breathing difficulties are a significant health concern, leading to substantial healthcare costs for patients. Understanding nasal airflow dynamics is crucial for comprehending respiratory mechanisms. This article presents a detailed study using tomo-Particle Image Velocimetry (PIV) to investigate nasal airflow dynamics while addressing its accuracy. Embedded in the OpenNose project, the work described aims to provide a validation basis for different numerical approaches to upper airway flow. The study includes the manufacturing of a transparent silicone model based on a clinical CT scan, refractive index matching to minimize optical distortions, and precise flow rate adjustments based on physiological breathing cycles. This method allows for spatial high-resolution investigations in different regions of interest within the nasopharynx during various phases of the breathing cycle. The results demonstrate the accuracy of the investigations, enabling detailed analysis of flow structures and gradients. This spatial high-resolution tomo-PIV approach provides valuable insights into the complex flow phenomena occurring during the physiological breathing cycle in the nasopharynx. The study's findings contribute to advancements in non-free-of-sight experimental flow investigation of complex cavities under nearly realistic conditions. Furthermore, reliable and accurate experimental data is crucial for properly validating numerical approaches that compute this patient-specific flow for clinical purposes. Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-70393 N1 - Corresponding author: Sandra Melina Tauwald VL - 35 IS - 5 PB - IOP Publishing ER - TY - GEN A1 - Tauwald, Sandra Melina A1 - Krenkel, Lars T1 - Elementary experimental setup for flow visualization in upper human respiratory tract T2 - 25th Congress of the European Society of Biomechanics, July 7-10, 2019, Vienna, Austria Y1 - 2019 UR - https://esbiomech.org/conference/archive/2019vienna/Contribution_195.pdf ER - TY - JOUR A1 - Tauwald, Sandra Melina A1 - Michel, Johanna A1 - Brandt, Marie A1 - Vielsmeier, Veronika A1 - Stemmer, Christian A1 - Krenkel, Lars T1 - Experimental studies and mathematical modeling of the viscoelastic rheology of tracheobronchial mucus from respiratory healthy patients JF - Multidisciplinary Respiratory Medicine N2 - BACKGROUND: Tracheobronchial mucus plays a crucial role in pulmonary function by providing protection against inhaled pathogens. Due to its composition of water, mucins, and other biomolecules, it has a complex viscoelastic rheological behavior. This interplay of both viscous and elastic properties has not been fully described yet. In this study, we characterize the rheology of human mucus using oscillatory and transient tests. Based on the transient tests, we describe the material behavior of mucus under stress and strain loading by mathematical models. METHODS: Mucus samples were collected from clinically used endotracheal tubes. For rheological characterization, oscillatory amplitude-sweep and frequency-sweep tests, and transient creep-recovery and stress-relaxation tests were performed. The results of the transient test were approximated using the Burgers model, the Weibull distribution, and the six-element Maxwell model. The three-dimensional microstructure of the tracheobronchial mucus was visualized using scanning electron microscope imaging. RESULTS: Amplitude-sweep tests showed storage moduli ranging from 0.1 Pa to 10000 Pa and a median critical strain of 4 %. In frequency-sweep tests, storage and loss moduli increased with frequency, with the median of the storage modulus ranging from 10 Pa to 30 Pa, and the median of the loss modulus from 5 Pa to 14 Pa. The Burgers model approximates the viscoelastic behavior of tracheobronchial mucus during a constant load of stress appropriately (R2 of 0.99), and the Weibull distribution is suitable to predict the recovery of the sample after the removal of this stress (R2 of 0.99). The approximation of the stress-relaxation test data by a six-element Maxwell model shows a larger fit error (R2 of 0.91). CONCLUSIONS: This study provides a detailed description of all process steps of characterizing the rheology of tracheobronchial mucus, including sample collection, microstructure visualization, and rheological investigation. Based on this characterization, we provide mathematical models of the rheological behavior of tracheobronchial mucus. These can now be used to simulate mucus flow in the respiratory system through numerical approaches. KW - tracheobronchial mucus KW - rheological model KW - viscoelasticity Y1 - 2023 U6 - https://doi.org/10.4081/mrm.2023.923 SN - 2049-6958 N1 - Corresponding author: Sandra Melina Tauwald VL - 18 IS - 1 PB - PAGEPress CY - Pavia, Italy ER - TY - GEN A1 - Tauwald, Sandra Melina A1 - Quadrio, Maurizio A1 - Rütten, Markus A1 - Stemmer, Christian A1 - Krenkel, Lars T1 - High Spatial Resolution Tomo-PIV of the Nasopharynx Focussing on the Physiological Breathing Cycle T2 - 23. DGLR Fach-Symposium Strömungen mit Ablösung, 09./10. November 2022, Berlin, Deutschland N2 - Investigations of complex patient-specific flow in the nasopharynx requires high resolution numerical calculations validated by reliable experiments. When building the validation base and the benchmark of computational fluid dynamics, an experimental setup of the nasal airways was developed. The applied optical measurement technique of tomo-PIV supplies information on the governing flow field in three dimensions. This paper presents tomo-PIV measurements of the highly complex patient-specific geometry of the human trachea. A computertomographic scan of a person’s head builds the basis of the experimental silicone model of the nasal airways. An optimised approach for precise refractive index matching avoids optical distortions even in highly complex non-free-of-sight 3D geometries. A linear-motor-driven pump generates breathing scenarios, based on measured breathing cycles. Adjusting of the CCD cameras‘ double-frame-rate PIV-Δt enables the detailed analysis of flow structures during different cycle phases. Merging regions of interest enables high spatial resolution acquisition of the flow field. KW - Tomographic PIV KW - Flow visualisation KW - Physiological Breathing KW - Nasal airflow Y1 - 2022 UR - https://www.dlr.de/as/Portaldata/5/Resources/dokumente/veranstaltungen/stab_workshop/Jahresbericht2022.pdf CY - Göttingen ER - TY - CHAP A1 - Tauwald, Sandra Melina A1 - Quadrio, Maurizio A1 - Rütten, Markus A1 - Stemmer, Christian A1 - Krenkel, Lars T1 - High Spatial Resolution Tomo-PIV of the Trachea Focussing on the Physiological Breathing Cycle T2 - New Results in Numerical and Experimental Fluid Mechanics XIV - Contributions to the 23nd STAB/DGLR Symposium N2 - Investigations of complex patient-specific flow in the nasopharynx requires high resolution numerical calculations validated by reliable experiments. When building the validation base and the benchmark of computational fluid dynamics, an experimental setup of the nasal airways was developed. The applied optical measurement technique of tomo-PIV supplies information on the governing flow field in three dimensions. This paper presents tomo-PIV measurements of the highly complex patient-specific geometry of the human trachea. A computertomographic scan of a person’s head builds the basis of the experimental silicone model of the nasal airways. An optimised approach for precise refractive index matching avoids optical distortions even in highly complex non-free-of-sight 3D geometries. A linear-motor-driven pump generates breathing scenarios, based on measured breathing cycles. Adjusting of the CCD cameras‘ double-frame-rate PIV-Δt enables the detailed analysis of flow structures during different cycle phases. Merging regions of interest enables high spatial resolution acquisition of the flow field. KW - Tomographic PIV KW - Flow visualisation KW - Breathing cycle KW - Nasal airflow Y1 - 2023 N1 - Accepted for publication, not yet published PB - Springer ER - TY - JOUR A1 - Uhrhan, Katja A1 - Schwindt, Esther A1 - Witte, Hartmut T1 - Fabrication and Dielectric Validation of an Arm Phantom for Electromyostimulation JF - Bioengineering N2 - Electromyostimulation (EMS) is an up-and-coming training method that demands further fundamental research regarding its safety and efficacy. To investigate the influence of different stimulation parameters, electrode positions and electrode sizes on the resulting voltage in the tissue, a tissue mimicking phantom is needed. Therefore, this study describes the fabrication of a hydrogel arm phantom for EMS applications with the tissue layers of skin, fat, blood and muscle. The phantom was dielectrically validated in the frequency range of 20 Hz to 100 Hz. We also conducted electromyography (EMG) recordings during EMS on the phantom and compared them with the same measurements on a human arm. The phantom reproduces the dielectric properties of the tissues with deviations ranging from 0.8% to more than 100%. Although we found it difficult to find a compromise between mimicking the permittivity and electrical conductivity at the same time, the EMS-EMG measurements showed similar waveforms (1.9-9.5% deviation) in the phantom and human. Our research contributes to the field of dielectric tissue phantoms, as it proposes a multilayer arm phantom for EMS applications. Consequently, the phantom can be used for initial EMS investigations, but future research should focus on further improving the dielectric properties. KW - tissue phantom KW - electromyostimulation KW - electrical muscle stimulation KW - dielectric validation KW - electromyography Y1 - 2024 U6 - https://doi.org/10.3390/bioengineering11070724 SN - 2306-5354 VL - 11 IS - 7 PB - MDPI CY - Basel ER - TY - JOUR A1 - Visscher, Rosa A1 - Wyss, C. A1 - Singh, Navrag B. A1 - Taylor, William R. A1 - Dendorfer, Sebastian A1 - Rutz, E. A1 - Brunner, Reinald T1 - Influence of TAL-TATS surgery on energy production of Tricepts Surae - A musculoskeletal modeling evaluation JF - Gait & Posture Y1 - 2020 U6 - https://doi.org/10.1016/j.gaitpost.2020.08.090 VL - 81 IS - Suppl. 1 SP - 381 EP - 382 PB - Elsevier ER - TY - JOUR A1 - Völlner, Florian A1 - Weber, Tim A. A1 - Weber, Markus A1 - Renkawitz, Tobias A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Craiovan, Benjamin T1 - A simple method for determining ligament stiffness during total knee arthroplasty in vivo JF - Scientific Reports N2 - A key requirement in both native knee joints and total knee arthroplasty is a stable capsular ligament complex. However, knee stability is highly individual and ranges from clinically loose to tight. So far, hardly any in vivo data on the intrinsic mechanical of the knee are available. This study investigated if stiffness of the native ligament complex may be determined in vivo using a standard knee balancer. Measurements were obtained with a commercially available knee balancer, which was initially calibrated in vitro. 5 patients underwent reconstruction of the force-displacement curves of the ligament complex. Stiffness of the medial and lateral compartments were calculated to measure the stability of the capsular ligament complex. All force-displacement curves consisted of a non-linear section at the beginning and of a linear section from about 80 N onwards. The medial compartment showed values of 28.4 ± 1.2 N/mm for minimum stiffness and of 39.9 ± 1.1 N/mm for maximum stiffness; the respective values for the lateral compartment were 19.9 ± 0.9 N/mm and 46.6 ± 0.8 N/mm. A commercially available knee balancer may be calibrated for measuring stiffness of knee ligament complex in vivo, which may contribute to a better understanding of the intrinsic mechanical behaviour of knee joints. KW - Biomechanische Analyse KW - Kniegelenkband KW - Steifigkeit Y1 - 2019 U6 - https://doi.org/10.1038/s41598-019-41732-x VL - 9 SP - 1 EP - 8 PB - Nature ER - TY - JOUR A1 - Wagner, Maria Stella A1 - Kranz, Michael A1 - Krenkel, Lars A1 - Pointner, Daniel A1 - Foltan, Maik A1 - Lubnow, Matthias A1 - Lehle, Karla ED - Becatti, Matteo T1 - Computer based visualization of clot structures in extracorporeal membrane oxygenation and histological clot investigations for understanding thrombosis in membrane lungs JF - Frontiers in Medicine N2 - Extracorporeal membrane oxygenation (ECMO) was established as a treatment for severe cardiac or respiratory disease. Intra-device clot formation is a common risk. This is based on complex coagulation phenomena which are not yet sufficiently understood. The objective was the development and validation of a methodology to capture the key properties of clots deposed in membrane lungs (MLs), such as clot size, distribution, burden, and composition. One end-oftherapy PLS ML was examined. Clot detection was performed using multidetector computed tomography (MDCT), microcomputed tomography (μCT), and photography of fiber mats (fiber mat imaging, FMI). Histological staining was conducted for von Willebrand factor (vWF), platelets (CD42b, CD62P), fibrin, and nucleated cells (4′, 6-diamidino-2-phenylindole, DAPI). The three imaging methods showed similar clot distribution inside the ML. Independent of the imaging method, clot loading was detected predominantly in the inlet chamber of the ML. The μCT had the highest accuracy. However, it was more expensive and time consuming than MDCT or FMI. The MDCT detected the clots with low scanning time. Due to its lower resolution, it only showed clotted areas but not the exact shape of clot structures. FMI represented the simplest variant, requiring little effort and resources. FMI allowed clot localization and calculation of clot volume. Histological evaluation indicated omnipresent immunological deposits throughout the ML. Visually clot-free areas were covered with leukocytes and platelets forming platelet-leukocyte aggregates (PLAs). Cells were embedded in vWF cobwebs, while vWF fibers were negligible. In conclusion, the presented methodology allowed adequate clot identification and histological classification of possible thrombosis markers such as PLAs. KW - ECMO KW - membrane lung KW - µCT KW - MDCT KW - shear induced clotting KW - vWF KW - histological evaluation Y1 - 2024 U6 - https://doi.org/10.3389/fmed.2024.1416319 IS - 11 PB - Frontiers ER - TY - GEN A1 - Wagner, Thomas A1 - Krenkel, Lars A1 - Dönitz, Christian A1 - Brawanski, Alexander T1 - Influence of CFD Strategy on WSS and OSI Determination for Intracranial Aneurysm Rupture Assessment T2 - 25th Congress of the European Society of Biomechanics, July 7-10, 2019, Vienna, Austria Y1 - 2019 ER - TY - JOUR A1 - Weber, Markus A1 - Merle, Christian A1 - Nawabi, Danyal H. A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Renkawitz, Tobias T1 - Inaccurate offset restoration in total hip arthroplasty results in reduced range of motion JF - Scientific Reports N2 - Offset restoration in total hip arthroplasty (THA) is associated with postoperative range of motion (ROM) and gait kinematics. We aimed to research into the impact of high offset (HO) and standard stems on postoperative ROM. 121 patients received cementless THA through a minimally-invasive anterolateral approach. A 360° hip ROM analysis software calculated impingement-free hip movement based on postoperative 3D-CTs compared to ROM values necessary for activities of daily living (ADL). The same model was then run a second time after changing the stem geometry between standard and HO configuration with the implants in the same position. HO stems showed higher ROM for all directions between 4.6 and 8.9° (p < 0.001) compared with standard stems but with high interindividual variability. In the subgroup with HO stems for intraoperative offset restoration, the increase in ROM was even higher for all ROM directions with values between 6.1 and 14.4° (p < 0.001) compared to offset underrestoration with standard stems. Avoiding offset underrestoration resulted in a higher amount of patients of over 20% for each ROM direction that fulfilled the criteria for ADL (p < 0.001). In contrast, in patients with standard stems for offset restoration ROM did increase but not clinically relevant by offset overcorrection for all directions between 3.1 and 6.1° (p < 0.001). Offset overcorrection by replacing standard with HO stems improved ROM for ADL in a low number of patients below 10% (p > 0.03). Patient-individual restoration of offset is crucial for free ROM in THA. Both over and underrestoration of offset should be avoided. KW - Adaptive clinical trial KW - Bone imaging Y1 - 2020 U6 - https://doi.org/10.1038/s41598-020-70059-1 VL - 10 IS - 13208 SP - 9 PB - Nature ER - TY - JOUR A1 - Weber, Markus A1 - Suess, Franz A1 - Jerabek, Seth A1 - Meyer, Matthias A1 - Grifka, Joachim A1 - Renkawitz, Tobias A1 - Dendorfer, Sebastian T1 - Kinematic pelvic tilt during gait alters functional cup position in total hip arthroplasty JF - Journal of Orthopaedic Research N2 - Static pelvic tilt impacts functional cup position in total hip arthroplasty (THA). In the current study we investigated the effect of kinematic pelvic changes on cup position. In the course of a prospective controlled trial postoperative 3D-computed tomography (CT) and gait analysis before and 6 and 12 months after THA were obtained in 60 patients. Kinematic pelvic motion during gait was measured using Anybody Modeling System. By fusion with 3D-CT, the impact of kinematic pelvic tilt alterations on cup anteversion and inclination was calculated. Furthermore, risk factors correlating with high pelvic mobility were evaluated. During gait a high pelvic range of motion up to 15.6° exceeding 5° in 61.7% (37/60) of patients before THA was found. After surgery, the pelvis tilted posteriorly by a mean of 4.0 ± 6.6° (p < .001). The pelvic anteflexion led to a mean decrease of −1.9 ± 2.2° (p < .001) for cup inclination and −15.1 ± 6.1° (p < .001) for anteversion in relation to the anterior pelvic plane (APP). Kinematic pelvic changes resulted in a further change up to 2.3° for inclination and up to 12.3° for anteversion. In relation to the preoperative situation differences in postoperative cup position ranged from −4.4 to 4.6° for inclination and from −7.8 to 17.9° for anteversion, respectively. Female sex (p < .001) and normal body weight (p < .001) correlated with high alterations in pelvic tilt. Kinematic pelvic changes highly impact cup anteversion in THA. Surgeons using the APP as reference should aim for a higher anteversion of about 15° due to the functional anteflexion of the pelvis during gait. KW - component position KW - gait analysis KW - kinematics KW - pelvic tilt KW - total hip arthroplasty KW - Hüftgelenkprothese KW - Haltungsfehler KW - Hüftgelenkpfanne Y1 - 2021 U6 - https://doi.org/10.1002/jor.25106 SN - 1554-527X VL - 40 IS - 4 SP - 846 EP - 853 PB - Wiley ER - TY - JOUR A1 - Weber, Markus A1 - Weber, Tim A. A1 - Woerner, Michael A1 - Craiovan, Benjamin A1 - Worlicek, Michael A1 - Winkler, Sebastian A1 - Grifka, Joachim A1 - Renkawitz, Tobias T1 - The impact of standard combined anteversion definitions on gait and clinical outcome within one year after total hip arthroplasty JF - International Orthopaedics N2 - Different target areas within the concept of combined cup and stem anteversion have been published for total hip arthroplasty (THA). We asked whether component positioning according to eight standard combined anteversion rules is associated with (1) more physiological gait patterns, (2) higher improvement of gait variables and (3) better clinical outcome after THA.In a prospective clinical study, 60 patients received cementless THA through an anterolateral MIS approach in a lateral decubitus position. Six weeks postoperatively, implant position was analysed using 3D-CT by an independent external institute. Preoperatively, six and 12 months postoperatively range of motion, normalized walking speed and hip flexion symmetry index were measured using 3D motion-capture gait analysis. Patient-related outcome measures (HHS, HOOS, EQ-5D) were obtained by an observer blinded to 3D-CT results. Eight combined anteversion definitions and Lewinnek's "safe zone" were evaluated regarding their impact on gait patterns and clinical outcome.Combined cup and stem anteversion according to standard combined anteversion definitions as well as cup placement within Lewinnek's "safe zone" did not influence range of motion, normalized walking speed and/or hip flexion symmetry index six and 12 months after THA. Similarly, increase of gait parameters within the first year after THA was comparable between all eight combined anteversion rules. Clinical outcome measures like HHS, HOOS and EQ-5D did not show any benefit for either of the combined anteversion definitions.Standard combined cup and stem anteversion rules do not improve postoperative outcome as measured by gait analysis and clinical scores within one year after THA. KW - Total hip athroplasty KW - Combined anteversion KW - Outcome KW - Gait analysis KW - Hüftgelenkprothese KW - Bewegungsanalyse KW - Gehen KW - Funktionelle Anatomie Y1 - 2015 U6 - https://doi.org/10.1007/s00264-015-2777-8 VL - 39 IS - 12 SP - 2323 EP - 2333 ER - TY - JOUR A1 - Weber, Tim A. A1 - Dendorfer, Sebastian A1 - Bulstra, Sjoerd K. A1 - Grifka, Joachim A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias T1 - Gait six month and one-year after computer assisted Femur First THR vs. conventional THR. Results of a patient- and observer- blinded randomized controlled trial JF - Gait & Posture N2 - A prospective randomized controlled trial is presented that is used to compare gait performance between the computer assisted Femur First (CAS FF) operation method and conventional THR (CON). 60 patients underwent a 3D gait analysis of the lower extremity at pre-operative, 6 months post-operative and twelve months post-operative. Detailed verification experiments were facilitated to ensure the quality of data as well as to avoid over-interpreting of the data. The results confirm a similar data-quality as reported in the literature. Walking speed, range of motion and symmetry thereof improved over the follow-up period, without significant differences between the groups. While all parameters do significantly increase over the follow-up period for both groups, there were no significant differences between them at any given time-point. Patients undergoing CAS FF showed a trend to improved hip flexion angle indicating a possible long-term benefit. KW - Biomechanics KW - Combined anteversion KW - Computer-assisted surgery KW - Femur first KW - Gait analysis Y1 - 2016 U6 - https://doi.org/10.1016/j.gaitpost.2016.06.035 VL - vol. 49 SP - 418 EP - 425 ER - TY - CHAP A1 - Weber, Tim A. A1 - Dendorfer, Sebastian A1 - Dullien, Silvia A1 - Grifka, Joachim A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias T1 - Measuring functional outcome after total hip replacement with subject-specific hip joint loading T2 - Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine N2 - Total hip replacement is an often-performed orthopedic surgical procedure; the amount of procedures undertaken will increase since our life expectancy is growing. In order to optimize function, hip biomechanics should be restored to as near normal as possible. The goal of this pilot study was to determine whether or not it is feasible to compute the vectorial hip reaction force pathways on the head of the prosthesis and the force angles relative to the cup of the prosthesis that occur during gait in total hip replacement patients, serving as an objective measurement of the functional outcome following hip replacement. A three-dimensional gait analysis, measuring ground reaction forces and kinematics, was performed. The data retrieved from the gait analysis was used as the input for the musculoskeletal model to compute vectorial joint reaction forces for data processing. To evaluate the position and orientation of the joint reaction forces, the force path, as well as the force angles for the operated and non-operated joint, has been calculated during the stance phase of the specific leg. The force path for subject 2 on the non-operated side is only located in the posterior-lateral quarter, as is the force path for subject 1. In contrast to this subject, the force path for subject 2 at the operated hip joint can be found only within the anterior quarter of the head of the implant, where it is nearly equally distributed in the medio-lateral half of the prosthesis head. The force-inclination angles on the cup of subject 1, with respect to the plane of the socket face, indicates that the force vector is mainly positioned in the same quadrant when compared with subject 2 (in a cup-fixed coordinate system). The force-anteversion angle behaves similarly to the force-inclination angle, even when the effects are not as pronounced. The proposed methods in this article are aiming to define two functional outcomes of total hip replacement that are related to wear and rim loading. It is accepted that wear is not only a function of time, but a function of use. Owing to the methods listed in this article, we are able to determine a) the applied force and b) the sliding distance (force pathway) in a subject-specific manner. The computed hip-reaction force angles and the distance to the rim cup are a measurement for cup or rim loading, and occurs in the so-called safe-zones. This method may well give us insight into the biomechanical situation during gait, after receiving total hip replacement, that we need to fully understand the mechanisms acting on a hip joint and to prove a possible increase of functional outcome after receiving total hip replacement. KW - total hip replacement KW - subject-specific musculoskeletal modeling KW - functional outcome KW - force pathways KW - force angles KW - critical hip joint loading KW - rim loading KW - cup loading KW - Hüftgelenkprothese KW - Biomechanik KW - Lastverteilung KW - Ganganalyse KW - Simulation Y1 - 2012 U6 - https://doi.org/10.1177/0954411912447728 VL - 226 IS - 12 SP - 939 EP - 946 ER - TY - JOUR A1 - Weber, Tim A. A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias ED - Takagi, Michiaki T1 - Does Computer-Assisted Femur First THR Improve Musculoskeletal Loading Conditions? JF - BioMed Research International N2 - We have developed a novel, computer-assisted operation method for minimal-invasive total hip replacement (THR) following the concept of “femur first/combined anteversion,” which incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position (CAS FF). The purpose of this study is to assess whether the hip joint reaction forces and patient’s gait parameters are being improved by CAS FF in relation to conventional THR (CON). We enrolled 60 patients (28 CAS FF/32 CON) and invited them for gait analysis at three time points (preoperatively, postop six months, and postop 12 months). Data retrieved from gait analysis was processed using patient-specific musculoskeletal models. The target parameters were hip reaction force magnitude (hrf), symmetries, and orientation with respect to the cup. Hrf in the CAS FF group were closer to a young healthy normal. Phase-shift symmetry showed an increase in the CAS FF group. Hrf orientation in the CAS FF group was closer to optimum, though no edge or rim-loading occurred in the CON group as well. The CAS FF group showed an improved hrf orientation in an early stage and a trend to an improved long-term outcome. KW - Hüftgelenkprothese KW - Operationstechnik KW - Computerunterstütztes Verfahren KW - Bewegungsapparat KW - Mechanische Belastung Y1 - 2015 U6 - https://doi.org/10.1155/2015/625317 VL - 2015 SP - ID 625317 ER - TY - JOUR A1 - Weber, Tim A1 - Al-Munajjed, Amir Andreas A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian A1 - Renkawitz, Tobias T1 - Influence of minimally invasive total hip replacement on hip reaction forces and their orientations JF - Journal of Orthopaedic Research N2 - Minimally invasive surgery (MIS) is becoming increasingly popular. Supporters claim that the main advantages of MIS total hip replacement (THR) are less pain and a faster rehabilitation and recovery. Critics claim that safety and efficacy of MIS are yet to be determined. We focused on a biomechanical comparison between surgical standard and MIS approaches for THR during the early recovery of patients. A validated, parameterized musculoskeletal model was set to perform a squat of a 50th percentile healthy European male. A bilateral motion was chosen to investigate effects on the contralateral side. Surgical approaches were simulated by excluding the incised muscles from the computations. Resulting hip reaction forces and their symmetry and orientation were analyzed. MIS THR seemed less influential on the symmetry index of hip reaction forces between the operated and nonoperated leg when compared to the standard lateral approach. Hip reaction forces at peak loads of the standard transgluteal approach were 24% higher on the contralateral side when compared to MIS approaches. Our results suggest that MIS THR contributes to a greater symmetry of hip reaction forces in absolute value as well as force-orientation following THR. KW - THA KW - THR KW - Biomechanics KW - Conventional surgery KW - Early recovery KW - Hüftgelenkprothese KW - Minimal-invasive Chirurgie KW - Biomechanik Y1 - 2014 U6 - https://doi.org/10.1002/jor.22710 VL - 32 IS - 12 SP - 1680 EP - 1687 ER - TY - CHAP A1 - Weber, Tim A1 - Dendorfer, Sebastian A1 - Bulstra, Sjoerd K. A1 - Grifka, Joachim A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tim T1 - Navigated Femur First Total Hip Arthroplasty leads to improved Biomechanical Outcome after surgery T2 - ORS annual meeting, Las Vegas, USA, 2015 Y1 - 2015 ER - TY - CHAP A1 - Weber, Tim A1 - Dendorfer, Sebastian A1 - Bulstra, Sjoerd K. A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias T1 - Musculoskeletal modeling for orthopedic surgery – Applications and chances T2 - Orthopedics meets Engineering, Regensburg, 2015 Y1 - 2015 ER - TY - CHAP A1 - Weber, Tim A1 - Dendorfer, Sebastian A1 - Bulstra, Sjoerd K. A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias T1 - Biomechanical Outcome after computer-assisted vs. Conventional THR T2 - ANSYS Conference & 32th CADFEM Users' Meeting 2014, 04.-06. Juni, Nürnberg Y1 - 2014 UR - https://www.researchgate.net/publication/264547774_Biomechanical_outcome_after_computer-assisted_vs_conventional_THR ER - TY - CHAP A1 - Weber, Tim A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Weber, Markus A1 - Wörner, Michael A1 - Dullien, Silvia A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias T1 - Verbessert die computerassistierte Femur First Operationstechnik für die Hüftendoprothetik den muskuloskelettalen Lastfall auf das Hüftgelenk? T2 - DKOU 2015, Deutscher Kongress für Orthopädie und Unfallchirurgie 2015 Y1 - 2015 UR - https://www.researchgate.net/publication/283259007_Verbessert_die_computerassistierte_Femur_First_Operationstechnik_fur_die_Huftendoprothetik_den_muskuloskelettalen_Lastfall_auf_das_Huftgelenk ER - TY - CHAP A1 - Weber, Tim A1 - Dendorfer, Sebastian A1 - Renkawitz, Tobias A1 - Dullien, Silvia A1 - Grifka, Joachim T1 - Clinical gait analysis combined with musculoskeletal modelling – coding a new generation of evaluation instruments T2 - Deutsche Gesellschaft für Biomechanik, Murnau, 2011 Y1 - 2011 ER - TY - JOUR A1 - Weber, Tim A1 - Dullien, Silvia A1 - Grifka, Joachim A1 - Renkawitz, Tobias A1 - Dendorfer, Sebastian T1 - Validation of a Motion Capture Laboratory and a new marker-placement protcol for clinical applications JF - Gait & Posture Y1 - 2013 U6 - https://doi.org/10.1016/j.gaitpost.2013.07.229 VL - 38 IS - Suppl. 1 SP - 113 EP - 114 ER - TY - CHAP A1 - Weber, Tim A1 - Dullien, Silvia A1 - Putzer, Michael A1 - Dendorfer, Sebastian A1 - Renkawitz, Tobias T1 - Biomechanical outcome after computer-assisted vs. conventional THR – study concept and preliminary gait analysis results T2 - GAMMA Workshop, Hannover, 2012 Y1 - 2012 ER - TY - CHAP A1 - Weber, Tim A1 - Renkawitz, Tobias A1 - Bulstra, Sjoerd K. A1 - Grifka, Joachim A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - Biomechanics of computer-assisted vs. conventional THR after one year follow up T2 - XXV Congress of the International Society of Biomechanics, Glasgow, UK, 12th-16th July 2015 Y1 - 2015 ER - TY - CHAP A1 - Weber, Tim A1 - Renkawitz, Tobias A1 - Grifka, Joachim A1 - Bulstra, Sjoerd K. A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - The musculoskeletal load scenario of computer-assisted Femur-First THR up to one year after surgery T2 - VI International Conference on Computational Bioengineering, Barcelona, Sept. 2015 Y1 - 2015 UR - https://www.researchgate.net/publication/281745827_The_musculoskeletal_load_scenario_of_computer-assisted_Femur-First_THR_up_to_one_year_after_surgery ER - TY - CHAP A1 - Weber, Tim A1 - Stezowski, P. A1 - Dullien, Silvia A1 - Dendorfer, Sebastian T1 - Eine biomechanische Bewertung verschiedener Belastungsszenarios nach der Implantierung einer Hüft-Totalendoprothese T2 - 89. Jahrestagung der Vereinigung der Bayerischen Chirurgen e.V., 25. - 27. Juli 2012, Regensburg T2 - A biomechanical evaluation of different load scenarios after implantation of a total hip replacement Y1 - 2012 ER - TY - CHAP A1 - Weber, Tim A1 - Stezowski, P. A1 - Dullien, Silvia A1 - Putzer, Michael A1 - Dendorfer, Sebastian T1 - Eine biomechanische Bewertung verschiedener Belastungsszenarien nach Implantierung einer Hüft-Totalendoprothese T2 - GAMMA Workshop, Hannover, 2012 Y1 - 2012 ER - TY - JOUR A1 - Weilhammer, Theresa A1 - Warren, Hunter S. A1 - Bliznyuk, Valery A1 - Kutsevol, Nataliya A1 - Booth, Brian W. T1 - Analysis of Photodynamic Therapeutic Treatment of HER2-Positive Breast Cancer In Vitro JF - BioNanoScience N2 - Photodynamic therapy (PDT) is a minimally invasive cancer treatment method. The antitumor effect of PDT mediated by the photosensitizer meta-tetra(hydroxyphenyl)chlorin (m-THPC) was studied in vitro on HER2-positive (HER2+) breast cancer cells. Since the application of m-THPC is limited due to poor tumor targeting abilities, the polymer carrier dextran-grafted-polyacrylamide (D-g-PAA) with attached gold nanoparticles was loaded with m-THPC to provide a light-responsive, tumor targeting nanocomposite. The nanocomposite was absorbed by the cancer cells within 90 min and activated through irradiation with red light at a wavelength of 660 nm. In this study, the efficiency and ideal dose of the nanocomposite were evaluated and determined based on cell viability and induction of apoptosis of HER2+ breast cancer cells and human breast epithelial cells. We demonstrate that the nanocomposite exhibited phototoxicity with cell mortality exceeding 50% for the HER2+ breast cancer cells. In contrast, the human breast epithelial cells were minimally affected at the same concentration of the nanocomposite, demonstrating the tumor-targeting abilities of the developed nanocomposite. Dark toxicity was also comparably lower, indicating the limited effect of the unactivated nanocomposite. The results revealed that apoptosis was the primary mode of cell death in HER2+ breast cancer cells. Apoptotic cell death was induced in HER2+ breast cancer cells via the caspase-3, caspase-9, and Bax pathways. In conclusion, the studied nanocomposite demonstrated excellent PDT performance with good antitumor activity under light irradiation in vitro and is worthy of further investigation as an alternative treatment for HER2+ breast cancer. Y1 - 2025 U6 - https://doi.org/10.1007/s12668-025-01940-4 VL - 15 PB - Springer ER - TY - CHAP A1 - Weiß, Roman A1 - Großmann, Benjamin A1 - Leibold, Marion A1 - Schlegl, Thomas A1 - Wollherr, Dirk A1 - Weiss, Roman A1 - Grossmann, Benjamin T1 - Modeling and nonlinear control of antagonistically actuating pneumatic artificial muscles T2 - 2017 IEEE International Conference on Advanced Intelligent Mechatronics (AIM), 3-7 July 2017, Munich, Germany N2 - This paper discusses modeling and nonlinear control of a joint antagonistically actuated by two pneumatic, artificial muscles. A single model of the whole system is obtained by a combined physical and phenomenological modeling approach. The combined model for the joint, the muscles and the proportional valves results in a nonlinear, affine-in-control system description. The model is used to derive control laws for an input/output linearization approach to linearize the plant. Modeling and parametrization errors are covered via an outer control loop consisting of a state-feedback which is extended by an additional feedback of error integral. Extensive experimental results show the quality of the model and the performance of the respective control laws. KW - FORCE KW - Muscles KW - Pulleys KW - Robot sensing systems KW - Transfer functions KW - Valves Y1 - 2017 U6 - https://doi.org/10.1109/AIM.2017.8014001 SP - 94 EP - 99 PB - IEEE ER - TY - JOUR A1 - Wessely, Rainer A1 - Hausleiter, Jörg A1 - Michaelis, Cornelia A1 - Jaschke, Birgit A1 - Vogeser, Michael A1 - Milz, Stefan A1 - Behnisch, Boris A1 - Schratzenstaller, Thomas A1 - Renke-Gluszko, Magdalena A1 - Stöver, Michael A1 - Wintermantel, Erich A1 - Kastrati, Adnan A1 - Schömig, Albert T1 - Inhibition of neointima formation by a novel drug-eluting stent system that allows for dose-adjustable, multiple, and on-site stent coating JF - Arteriosclerosis, Thrombosis, and Vascular Biology N2 - Objective The risk of in-stent restenosis can be considerably reduced by stents eluting cytostatic compounds. We created a novel drug-eluting stent system that includes several new features in the rapidly evolving field of stent-based drug delivery. Methods and Results The aim of the present study was the preclinical evaluation of a stent-coating system permitting individual, on-site coating of stents with a unique microporous surface allowing for individualizable, dose-adjustable, and multiple coatings with identical or various compounds, designated ISAR (individualizable drug-eluting stent system to abrogate restenosis). Stents were coated with 0.75% rapamycin solution, and high-performance liquid chromatography (HPLC)-based determination of drug release profile indicated drug release for >21 days. Rapamycin-eluting microporous (REMP) stents implanted in porcine coronary arteries were safe. To determine the efficacy of REMP stents, this novel drug-eluting stent platform was compared with the standard sirolimus-eluting stent. At 30 days, in-stent neointima formation in porcine coronary arteries was similar in both groups, yielding a significant decrease of neointimal area and injury-dependent neointimal thickness compared with bare-metal stents. Conclusion The ISAR drug-eluting stent platform as a novel concept for stent coating allows for a safe, effective, on-site stent coating process, thus justifying further clinical evaluation to decrease in-stent restenosis in humans. In-stent neointima formation can be successfully attenuated by drug-eluting stents. We introduce a novel conceptual approach for stent-coating that allows for dose-adjustable, on-site stent coating process if desired with multiple compounds. Microporous stents coated with rapamycin proved safe and effective for the limitation of neointima formation in a porcine coronary stent model. KW - drug-eluting stent KW - stent platform KW - sirolimus KW - rapamycin Y1 - 2005 U6 - https://doi.org/10.1161/01.ATV.0000157579.52566.ee SN - 1524-4636 VL - 25 IS - 4 SP - 748 EP - 753 ER - TY - CHAP A1 - Wiesent, Lisa A1 - Geith, Markus A. A1 - Wagner, Marcus T1 - Simulation of Fluid-Structure Interaction between injection medium and balloon catheter using ICFD T2 - 11th European LS-DYNA Conference 2017, 9 - 11 May, Salzburg, Austria N2 - Arteriosclerosis is a major health issue worldwide. While it is commonly treated by the implantation of an balloon-expandable stent, micro injuries may occur during stent deployment, and induce in-stent restenosis, whose consequence can be fatal. Studying this undesirable phenomenon is usually limited as experimental data is hard to obtain on ethical ground. Numerical simulation are performed to better understand this problem. To construct a more realistic simulation of a balloon-expandable stent, a partitioned strongly-coupled FSI simulation of the balloon deployment was set up using the ICFD solver of LS-DYNA, - a quite innovative approach. The complex balloon configuration as well as the interaction of the injection medium and the balloon structure was considered. The balloon structure consisting of shell elements was obtained from preliminary balloon folding and pleating simulations. The balloon consists of a flexible thin walled polyamide. The injection fluid is implemented using volume elements. Balloon deployment was initiated by a pressure boundary condition inducing a volume flow into the balloon. The initial feasibility analysis showed promising result including a continuous balloon deployment and a reasonable development of the fluid pressure and velocity field. However, applying this FSI approach to a more complex balloon structure led to a non convergent solution. The non-convergence could be mainly reduced to mechanical factors including the low wall thickness of the balloon (< 0.05 mm) and the flexibility of the polyamide. Further, the ICFD solver shows less accuracy concerning the FSI conditions when dealing with thin flexible structures as well as enclosed volumes. A shell thickness of 0.06 mm is believed to result in a convergent solution. KW - Koronare Herzkrankheit KW - Stent KW - Ballondilatation KW - Numerische Strömungssimulation Y1 - 2017 UR - https://www.dynalook.com/conferences/11th-european-ls-dyna-conference/icfd-solver-and-fsi/simulation-of-fluid-structure-interaction-between-injection-medium-and-balloon-catheter-using-icfd SN - 978-3981621549 ER - TY - GEN A1 - Wiesent, Lisa A1 - Hupke, Constantin A1 - Balk, Christian A1 - Schultheiss, Ulrich A1 - Schratzenstaller, Thomas T1 - Optimization of the cardiovascular stent design towards improved expansion behaviour and radial stiffness properties T2 - Biomedizinische Technik N2 - - Development of a FEA Tool for a realistic stent simulation - investigation on minor modification on the stent design on the expansion behaviour - analysis of three stent designs: classical stent design with pronounced dogbone effect, two modified stent design (non-dogbone-design) KW - Kardiovaskuläres System KW - Stent Y1 - 2018 U6 - https://doi.org/10.1515/bmt-2018-6031 VL - 63 IS - s1 ER - TY - JOUR A1 - Wiesent, Lisa A1 - Schultheiss, Ulrich A1 - Schmid, Christof A1 - Schratzenstaller, Thomas A1 - Nonn, Aida T1 - Experimentally validated simulation of coronary stents considering different dogboning ratios and asymmetric stent positioning JF - PlOS One N2 - In-stent restenosis remains a major problem of arteriosclerosis treatment by stenting. Expansion-optimized stents could reduce this problem. With numerical simulations, stent designs/ expansion behaviours can be effectively analyzed. For reasons of efficiency, simplified models of balloon-expandable stents are often used, but their accuracy must be challenged due to insufficient experimental validation. In this work, a realistic stent life-cycle simulation has been performed including balloon folding, stent crimping and free expansion of the balloon-stent-system. The successful simulation and validation of two stent designs with homogenous and heterogeneous stent stiffness and an asymmetrically positioned stent on the balloon catheter confirm the universal applicability of the simulation approach. Dogboning ratio, as well as the final dimensions of the folded balloon, the crimped and expanded stent, correspond well to the experimental dimensions with only slight deviations. In contrast to the detailed stent life-cycle simulation, a displacement-controlled simulation can not predict the transient stent expansion, but is suitable to reproduce the final expanded stent shape and the associated stress states. The detailed stent life-cycle simulation is thus essential for stent expansion analysis/optimization, whereas for reasons of computational efficiency, the displacement-controlled approach can be considered in the context of pure stress analysis. KW - Catheters KW - Coronary stenting KW - Deformation KW - Stent implantation KW - Stiffness KW - Stent KW - Ballondilatation KW - Numerische Strömungssimulation Y1 - 2019 U6 - https://doi.org/10.1371/journal.pone.0224026 VL - 14 IS - 10 SP - 1 EP - 25 PB - PLOS ER - TY - JOUR A1 - Wiesent, Lisa A1 - Schultheiß, Ulrich A1 - Lulla, Philipp A1 - Noster, Ulf A1 - Schratzenstaller, Thomas A1 - Schmid, Christof A1 - Nonn, Aida A1 - Spear, Ashley T1 - Computational analysis of the effects of geometric irregularities and post-processing steps on the mechanical behavior of additively manufactured 316L stainless steel stents JF - PLoS ONE N2 - Advances in additive manufacturing enable the production of tailored lattice structures and thus, in principle, coronary stents. This study investigates the effects of process-related irregularities, heat and surface treatment on the morphology, mechanical response, and expansion behavior of 316L stainless steel stents produced by laser powder bed fusion and provides a methodological approach for their numerical evaluation. A combined experimental and computational framework is used, based on both actual and computationally reconstructed laser powder bed fused stents. Process-related morphological deviations between the as-designed and actual laser powder bed fused stents were observed, resulting in a diameter increase by a factor of 2-2.6 for the stents without surface treatment and 1.3-2 for the electropolished stent compared to the as-designed stent. Thus, due to the increased geometrically induced stiffness, the laser powder bed fused stents in the as-built (7.11 ± 0.63 N) or the heat treated condition (5.87 ± 0.49 N) showed increased radial forces when compressed between two plates. After electropolishing, the heat treated stents exhibited radial forces (2.38 ± 0.23 N) comparable to conventional metallic stents. The laser powder bed fused stents were further affected by the size effect, resulting in a reduced yield strength by 41% in the as-built and by 59% in the heat treated condition compared to the bulk material obtained from tensile tests. The presented numerical approach was successful in predicting the macroscopic mechanical response of the stents under compression. During deformation, increased stiffness and local stress concentration were observed within the laser powder bed fused stents. Subsequent numerical expansion analysis of the derived stent models within a previously verified numerical model of stent expansion showed that electropolished and heat treated laser powder bed fused stents can exhibit comparable expansion behavior to conventional stents. The findings from this work motivate future experimental/numerical studies to quantify threshold values of critical geometric irregularities, which could be used to establish design guidelines for laser powder bed fused stents/lattice structures. KW - Heat treatment KW - Lasers KW - Surface treatments KW - Specimen preparation and treatment KW - Material properties KW - Stiffness KW - Deformation KW - Powders KW - Koronarendoprothese KW - Rapid prototyping KW - Numerische Methode Y1 - 2020 U6 - https://doi.org/10.1371/journal.pone.0244463 N1 - Corresponding author: Lisa Wiesent VL - 15 IS - 12 SP - 1 EP - 30 PB - PLOS ER - TY - JOUR A1 - Wiesent, Lisa A1 - Spear, Ashley A1 - Nonn, Aida T1 - Computational analysis of the effects of geometric irregularities on the interaction of an additively manufactured 316L stainless steel stent and a coronary artery JF - Journal of the Mechanical Behavior of Biomedical Materials N2 - Customized additively manufactured (laser powder bed fused (L-PBF)) stents could improve the treatment of complex lesions by enhancing stent-artery conformity. However, geometric irregularities inherent for L-PBF stents are expected to influence not only their mechanical behavior but also their interaction with the artery. In this study, the influence of geometrical irregularities on stent-artery interaction is evaluated within a numerical framework. Thus, computed arterial stresses induced by a reconstructed L-PBF stent model are compared to those induced by the intended stent model (also representing a stent geometry obtained from conventional manufacturing processes) and a modified CAD stent model that accounts for the increased strut thickness inherent for L-PBF stents. It was found that, similar to conventionally manufactured stents, arterial stresses are initially related to the basic stent design/topology, with the highest stresses occurring at the indentations of the stent struts. Compared to the stent CAD model, the L-PBF stent induces distinctly higher and more maximum volume stresses within the plaque and the arterial wall. In return, the modified CAD model overestimates the arterial stresses induced by the L-PBF stent due to its homogeneously increased strut thickness and thus its homogeneously increased geometric stiffness compared with the L-PBF stent. Therefore, the L-PBF-induced geometric irregularities must be explicitly considered when evaluating the L-PBF stent-induced stresses because the intended stent CAD model underestimates the arterial stresses, whereas the modified CAD model overestimates them. The arterial stresses induced by the L-PBF stent were still within the range of values reported for conventional stents in literature, suggesting that the use of L-PBF stents is conceivable in principle. However, because geometric irregularities, such as protruding features from the stent surface, could potentially damage the artery or lead to premature stent failure, further improvement of L-PBF stents is essential. KW - Laser powder bed fusion (L-PBF) KW - Cardiovascular stents KW - Finite element analysis (FEA) KW - Geometrical imperfections KW - Stent-artery interaction Y1 - 2022 U6 - https://doi.org/10.1016/j.jmbbm.2021.104878 SN - 1751-6161 VL - 125 PB - Elsevier ER - TY - JOUR A1 - Wong, Christian A1 - Rasmussen, John A1 - Simonsen, Erik B. A1 - Hansen, Lone A1 - de Zee, Mark A1 - Dendorfer, Sebastian T1 - The Influence of Muscle Forces on the Stress Distribution in the Lumbar Spine JF - The Open Spine Journal N2 - Introduction: Previous studies of bone stresses in the human lumbar spine have relied on simplified models when modeling the spinal musculature, even though muscle forces are likely major contributors to the stresses in the vertebral bones. Detailed musculoskeletal spine models have recently become available and show good correlation with experimental findings. A combined inverse dynamics and finite element analysis study was conducted in the lumbar spine to investigate the effects of muscle forces on a detailed musculoskeletal finite element model of the 4th lumbar vertebral body. Materials and Methodology: The muscle forces were computed with a detailed and validated inverse dynamics musculoskeletal spine model in a lifting situation, and were then applied to an orthotropic finite element model of the 4th lumbar vertebra. The results were compared with those from a simplified load case without muscles. Results: In general the von Mises stress was larger by 30%, and even higher when looking at the von Mises stress distribution in the superio-anterior and central part of the vertebral body and in the pedicles. Conclusion: The application of spine muscles to a finite element model showed markedly larger von Mises stress responses in the central and anterior part of the vertebral body, which can be tolerated in the young and healthy spine, but it would increase the risk of compression fractures in the elderly, osteoporotic spine. KW - Lumbar spine KW - Muscle influence KW - Inverse dynamics KW - Finite element analysis KW - Lendenwirbelsäule KW - Muskelkraft KW - Belastung KW - Finite-Elemente-Methode Y1 - 2011 U6 - https://doi.org/10.2174/1876532701103010021 VL - 3 IS - 1 SP - 21 EP - 26 ER - TY - JOUR A1 - Zellner, Johannes A1 - Hierl, Katja A1 - Mueller, Michael A1 - Pfeifer, Christian A1 - Berner, Arne A1 - Dienstknecht, Thomas A1 - Krutsch, Werner A1 - Geis, Sebastian A1 - Gehmert, Sebastian A1 - Kujat, Richard A1 - Dendorfer, Sebastian A1 - Prantl, Lukas A1 - Nerlich, Michael A1 - Angele, Peter ED - Gilbert, Jeremy T1 - Stem cell-based tissue-engineering for treatment of meniscal tears in the avascular zone JF - Journal of Biomedical Materials Research Part B Applied Biomaterials N2 - Meniscal tears in the avascular zone have a poor self-healing potential, however partial meniscectomy predisposes the knee for early osteoarthritis. Tissue engineering with mesenchymal stem cells and a hyaluronan collagen based scaffold is a promising approach to repair meniscal tears in the avascular zone. 4 mm longitudinal meniscal tears in the avascular zone of lateral menisci of New Zealand White Rabbits were performed. The defect was left empty, sutured with a 5-0 suture or filled with a hyaluronan/collagen composite matrix without cells, with platelet rich plasma or with autologous mesenchymal stem cells. Matrices with stem cells were in part precultured in chondrogenic medium for 14 days prior to the implantation. Menisci were harvested at 6 and 12 weeks. The developed repair tissue was analyzed macroscopically, histologically and biomechanically. Untreated defects, defects treated with suture alone, with cell-free or with platelet rich plasma seeded implants showed a muted fibrous healing response. The implantation of stem cell-matrix constructs initiated fibrocartilage-like repair tissue, with better integration and biomechanical properties in the precultured stem cell-matrix group. A hyaluronan-collagen based composite scaffold seeded with mesenchymal stem cells is more effective in the repair avascular meniscal tear with stable meniscus-like tissue and to restore the native meniscus. KW - biomechanics KW - meniscus KW - scaffolds KW - stem cells KW - tissue engineering KW - Meniskusschaden KW - Tissue Engineering KW - Mesenchymzelle KW - Hyaluronsäure Y1 - 2013 U6 - https://doi.org/10.1002/jbm.b.32922 VL - 101 IS - 7 SP - 1133 EP - 1142 ER - TY - JOUR A1 - Zentgraf, Jan A1 - Nützel, Florian A1 - Mühlbauer, Nico A1 - Schultheiss, Ulrich A1 - Grad, Marius A1 - Schratzenstaller, Thomas T1 - Surface Treatment of Additively Manufactured Polyetheretherketone (PEEK) by Centrifugal Disc Finishing Process: Identification of the Key Parameters JF - Polymers N2 - Polyetheretherketone is a promising material for implants due to its good mechanical properties and excellent biocompatibility. Its accessibility to a wide range of applications is facilitated by the ability to process it with an easy-to-use manufacturing process such as fused filament fabrication. The elimination of disadvantages associated with the manufacturing process, such as a poor surface quality, is a main challenge to deal with. As part of the mass finishing process, centrifugal disc finishing has demonstrated good results in surface optimization, making it a promising candidate for the post-processing of additively manufactured parts. The objective of this study is to identify the key parameters of the centrifugal disc finishing process on the waviness of additively manufactured PEEK specimens, which has not been investigated previously. The waviness of the specimen was investigated by means of confocal laser scanning microscopy (CLSM), while weight loss was additionally tracked. Six parameters were investigated: type, amount and speed of media, use of compound, amount of water and time. Type of media, time and speed were found to significantly influence waviness reduction and weight loss. Surface electron microscopy images demonstrated the additional effects of deburring and corner rounding. Results on previous studies with specimens made of metal showed similar results. Further investigation is required to optimize waviness reduction and polish parts in a second post-processing step. KW - PEEK KW - fused deposition modeling KW - fused filament fabrication KW - centrifugal disc finishing KW - mass finishing KW - 3D printing KW - post-processing of 3D printed parts KW - surface treatment KW - high-performance polymers KW - additive manufacturing Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-73959 SN - 2073-4360 N1 - Corresponding author der OTH Regensburg: Jan Zentgraf VL - 16 PB - MDPI CY - Basel ER - TY - GEN ED - Frommeld, Debora ED - Scorna, Ulrike ED - Haug, Sonja ED - Weber, Karsten T1 - Gute Technik für ein gutes Leben im Alter? BT - Akzeptanz, Chancen und Herausforderungen altersgerechter Assistenzsysteme N2 - Längst gibt es altersgerechte digitale Assistenzsysteme. Doch sind Umfang und Geschwindigkeit ihrer Verbreitung sowohl in Pflegeeinrichtungen als auch in privaten Haushalten weitgehend unbekannt. Informationen zu tatsächlich eingesetzten Systemen, realisierten Umsätzen und Marktvolumen sind kaum zu finden. Obwohl es viele Vermutungen hinsichtlich der Hindernisse bei der Einführung altersgerechter Assistenzsysteme gibt, sind auch hier verlässliche Aussagen rar. Die Beiträge des Bandes liefern auf Basis empirischer Untersuchungen und theoretischer Überlegungen Antworten und zeigen auf, wie vielgestaltig die Faktoren sind, die die Diffusion altersgerechter Assistenzsysteme hemmen oder fördern. KW - Alter KW - Altenpflege KW - Assistenzsystem KW - Künstliche Intelligenz KW - Medizintechnik KW - Arbeitshilfe Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-149 SN - 978-3-8376-5469-1 PB - transcript Verlag CY - Bielefeld ER - TY - GEN ED - Hammer, Joachim ED - Nerlich, Michael ED - Dendorfer, Sebastian T1 - Medicine Meets Engineering: Proceedings of the 2nd Conference on Applied Biomechanics Regensburg N2 - Biomedical Engineering is defined as the science that integrates medical and engineering sciences to improve diagnosis and treatment of patients. Only by this integration progress can be achieved. Both medical and engineering sciences comprise a huge diversity in topics, so it is imaginable that Biomedical Engineering, combining these two science areas, is even more huge. Thanks to this megadisciplinary approach many breakthroughs can be achieved. More and more research groups realize this and start new research projects, which results in a rapid increase in knowledge in Biomedical Engineering. This will only benefit the main goal of Biomedical Engineering; improving diagnosis and treatment of patients when it is spread and applied. The 2nd Regensburg Applied Biomechanics conference is special in that it realized both the distribution of new knowledge and the essential integration of medical and engineering specialists. The conference dealt with the latest results in applied biomechanics, ranging from fundamental bone strength properties via bone remodeling phenomena to new implants that replace lost human functions. Also new research areas like robot surgery and tissue engineering were discussed. KW - Biomechanik Y1 - 2008 SN - 978-1586038281 PB - IOS Press, US ET - 1. Aufl. ER -