TY - JOUR A1 - Wessely, Rainer A1 - Hausleiter, Jörg A1 - Michaelis, Cornelia A1 - Jaschke, Birgit A1 - Vogeser, Michael A1 - Milz, Stefan A1 - Behnisch, Boris A1 - Schratzenstaller, Thomas A1 - Renke-Gluszko, Magdalena A1 - Stöver, Michael A1 - Wintermantel, Erich A1 - Kastrati, Adnan A1 - Schömig, Albert T1 - Inhibition of neointima formation by a novel drug-eluting stent system that allows for dose-adjustable, multiple, and on-site stent coating JF - Arteriosclerosis, Thrombosis, and Vascular Biology N2 - Objective The risk of in-stent restenosis can be considerably reduced by stents eluting cytostatic compounds. We created a novel drug-eluting stent system that includes several new features in the rapidly evolving field of stent-based drug delivery. Methods and Results The aim of the present study was the preclinical evaluation of a stent-coating system permitting individual, on-site coating of stents with a unique microporous surface allowing for individualizable, dose-adjustable, and multiple coatings with identical or various compounds, designated ISAR (individualizable drug-eluting stent system to abrogate restenosis). Stents were coated with 0.75% rapamycin solution, and high-performance liquid chromatography (HPLC)-based determination of drug release profile indicated drug release for >21 days. Rapamycin-eluting microporous (REMP) stents implanted in porcine coronary arteries were safe. To determine the efficacy of REMP stents, this novel drug-eluting stent platform was compared with the standard sirolimus-eluting stent. At 30 days, in-stent neointima formation in porcine coronary arteries was similar in both groups, yielding a significant decrease of neointimal area and injury-dependent neointimal thickness compared with bare-metal stents. Conclusion The ISAR drug-eluting stent platform as a novel concept for stent coating allows for a safe, effective, on-site stent coating process, thus justifying further clinical evaluation to decrease in-stent restenosis in humans. In-stent neointima formation can be successfully attenuated by drug-eluting stents. We introduce a novel conceptual approach for stent-coating that allows for dose-adjustable, on-site stent coating process if desired with multiple compounds. Microporous stents coated with rapamycin proved safe and effective for the limitation of neointima formation in a porcine coronary stent model. KW - drug-eluting stent KW - stent platform KW - sirolimus KW - rapamycin Y1 - 2005 U6 - https://doi.org/10.1161/01.ATV.0000157579.52566.ee SN - 1524-4636 VL - 25 IS - 4 SP - 748 EP - 753 ER - TY - JOUR A1 - Wiesent, Lisa A1 - Schultheiss, Ulrich A1 - Schmid, Christof A1 - Schratzenstaller, Thomas A1 - Nonn, Aida T1 - Experimentally validated simulation of coronary stents considering different dogboning ratios and asymmetric stent positioning JF - PlOS One N2 - In-stent restenosis remains a major problem of arteriosclerosis treatment by stenting. Expansion-optimized stents could reduce this problem. With numerical simulations, stent designs/ expansion behaviours can be effectively analyzed. For reasons of efficiency, simplified models of balloon-expandable stents are often used, but their accuracy must be challenged due to insufficient experimental validation. In this work, a realistic stent life-cycle simulation has been performed including balloon folding, stent crimping and free expansion of the balloon-stent-system. The successful simulation and validation of two stent designs with homogenous and heterogeneous stent stiffness and an asymmetrically positioned stent on the balloon catheter confirm the universal applicability of the simulation approach. Dogboning ratio, as well as the final dimensions of the folded balloon, the crimped and expanded stent, correspond well to the experimental dimensions with only slight deviations. In contrast to the detailed stent life-cycle simulation, a displacement-controlled simulation can not predict the transient stent expansion, but is suitable to reproduce the final expanded stent shape and the associated stress states. The detailed stent life-cycle simulation is thus essential for stent expansion analysis/optimization, whereas for reasons of computational efficiency, the displacement-controlled approach can be considered in the context of pure stress analysis. KW - Catheters KW - Coronary stenting KW - Deformation KW - Stent implantation KW - Stiffness KW - Stent KW - Ballondilatation KW - Numerische Strömungssimulation Y1 - 2019 U6 - https://doi.org/10.1371/journal.pone.0224026 VL - 14 IS - 10 SP - 1 EP - 25 PB - PLOS ER - TY - GEN A1 - Kögler, Michael A1 - Ismail, Khaled M. A1 - Rusavy, Zdenek A1 - Kalis, Vladimir A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Influence of bed height and stance on accoucheurs lower back and glenohumeral load during simulated childbirth T2 - 31st meeting of Czech Urogynaecological Society, Prague, 2022 Y1 - 2022 ER - TY - JOUR A1 - Manaranche, Claire A1 - Hornberger, Helga T1 - A proposal for the classification of dental alloys according to their resistance to corrosion JF - Dental Materials N2 - Objectives The purpose of this study was to establish a method to compare and classify dental alloys in relation to their resistance to corrosion. Methods Alloy samples and pure metal samples were prepared and tested in chemical and electrochemical corrosion according to ISO 10271. For electrochemical test, the rest potential versus time and a potentiodynamic scan were recorded. After chemical corrosion test, the ions released were analyzed by ICP (induced coupled plasma) spectroscopy. Results High gold alloys had a similar polarization curve than gold. The same effect was observed for Pd–base alloys, their curves were similar to the one of palladium. The ions released during chemical corrosion were non-precious metallic ions. Thereby Ni–Cr alloys were found to release the most ions. Au–Pt alloys showed the highest release of ions compared with other precious alloys but low compared with Ni–Cr. Electrochemical corrosion was more aggressive than chemical corrosion and every type of elements was etched, the higher the precious metal content, the higher the resistance to corrosion of the alloy. Discussion Using the recorded data, a classification system for electrochemical corrosion was developed and discussed to judge the results. Hereby were gold and zinc used as reference materials. The applied classification system defines five classes and it is proposed that alloys of class V are not acceptable. For chemical corrosion resistance, three classes were distinguished according to the quantity of metallic ions released and it is proposed that class III (100–1000 μg/cm2 week) is not acceptable. Palladium and Pd–base alloys showed a higher electrochemical and chemical corrosion resistance than gold. KW - Dental alloys KW - Precious alloys KW - Corrosion test KW - Resistance to corrosion KW - Classification KW - Ion release Y1 - 2007 U6 - https://doi.org/10.1016/j.dental.2006.11.030 VL - 23 IS - 11 SP - 1428 EP - 1437 ER - TY - JOUR A1 - Dendorfer, Sebastian A1 - Melzner, Maximilian T1 - Rückenschmerzen bei Geburtshelfer:innen. Die Haltung macht's. JF - Deutsche Hebammen-Zeitschrift N2 - Für Mutter und Kind konnte das Risiko der Geburt durch die Weiterentwicklung der Medizin drastisch reduziert werden. Doch wie ist es um das Wohl derer bestellt, die die Gebärende unterstützen? Eine Studie der Ostbayerischen Technischen Hochschule Regensburg hat sich mit den muskuloskelettalen Beschwerden von Geburtshelfer:innen auseinandergesetzt Y1 - 2022 UR - https://ip.staudeverlag.de/de/profiles/c3962f735915-elwin-staude-verlag-kiosk-bc/editions/dhz-11-2022/pages/page/32 SN - 0012-026X VL - 74 IS - 11 SP - 60 EP - 62 PB - Staude CY - Hannover ER - TY - JOUR A1 - Kheiroddin, Parastoo A1 - Schöberl, Patricia A1 - Althammer, Michael A1 - Cibali, Ezgi A1 - Würfel, Thea A1 - Wein, Hannah A1 - Kulawik, Birgit A1 - Buntrock-Döpke, Heike A1 - Weigl, Eva A1 - Gran, Silvia A1 - Gründl, Magdalena A1 - Langguth, Jana A1 - Lampl, Benedikt A1 - Judex, Guido A1 - Niggel, Jakob A1 - Pagel, Philipp A1 - Schratzenstaller, Thomas A1 - Schneider-Brachert, Wulf A1 - Gastiger, Susanne A1 - Bodenschatz, Mona A1 - Konrad, Maike A1 - Levchuk, Artem A1 - Roth, Cornelius A1 - Schöner, David A1 - Schneebauer, Florian A1 - Rohrmanstorfer, René A1 - Burkovski, Andreas A1 - Ambrosch, Andreas A1 - Wagner, Thomas A1 - Kabesch, Michael ED - Buonsenso, Danilo T1 - Results of WICOVIR Gargle Pool PCR Testing in German Schools Based on the First 100,000 Tests JF - Frontiers in Pediatrics N2 - Background: Opening schools and keeping children safe from SARS-CoV-2 infections at the same time is urgently needed to protect children from direct and indirect consequences of the COVID-19 pandemic. To achieve this goal, a safe, efficient, and cost-effective SARS-CoV-2 testing system for schools in addition to standard hygiene measures is necessary. Methods: We implemented the screening WICOVIR concept for schools in the southeast of Germany, which is based on gargling at home, pooling of samples in schools, and assessment of SARS-CoV-2 by pool rRT-PCR, performed decentralized in numerous participating laboratories. Depooling was performed if pools were positive, and results were transmitted with software specifically developed for the project within a day. Here, we report the results after the first 13 weeks in the project. Findings: We developed and implemented the proof-of-concept test system within a pilot phase of 7 weeks based on almost 17,000 participants. After 6 weeks in the main phase of the project, we performed >100,000 tests in total, analyzed in 7,896 pools, identifying 19 cases in >100 participating schools. On average, positive children showed an individual CT value of 31 when identified in the pools. Up to 30 samples were pooled (mean 13) in general, based on school classes and attached school staff. All three participating laboratories detected positive samples reliably with their previously established rRT-PCR standard protocols. When self-administered antigen tests were performed concomitantly in positive cases, only one of these eight tests was positive, and when antigen tests performed after positive pool rRT-PCR results were already known were included, 3 out of 11 truly positive tests were also identified by antigen testing. After 3 weeks of repetitive WICOVIR testing twice weekly, the detection rate of positive children in that cohort decreased significantly from 0.042 to 0.012 (p = 0.008). Interpretation: Repeated gargle pool rRT-PCR testing can be implemented quickly in schools. It is an effective, valid, and well-received test system for schools, superior to antigen tests in sensitivity, acceptance, and costs. KW - children KW - COVID-19 KW - Germany KW - PCR KW - pooling KW - gargle KW - schools KW - pandemic KW - Covid-19 KW - Polymerase-Kettenreaktion KW - Nachweis KW - Schulkind KW - Deutschland Y1 - 2021 U6 - https://doi.org/10.3389/fped.2021.721518 SN - 2296-2360 VL - 9 PB - frontiers ER - TY - JOUR A1 - Geith, Markus A. A1 - Nothdurfter, Laurenz A1 - Heiml, Manuel A1 - Agrafiotis, Emmanouil A1 - Gruber, Markus A1 - Sommer, Gerhard A1 - Schratzenstaller, Thomas A1 - Holzapfel, Gerhard A. T1 - Quantifying stent-induced damage in coronary arteries by investigating mechanical and structural alterations JF - Acta Biomaterialia N2 - Vascular damage develops with diverging severity during and after percutaneous coronary intervention with stent placement and is the prevailing stimulus for in-stent restenosis. Previous work has failed to link mechanical data obtained in a realistic in vivo or in vitro environment with data collected during imaging processes. We investigated whether specimens of porcine right coronary arteries soften when indented with a stent strut shaped structure, and if the softening results from damage mechanisms inside the fibrillar collagen structure. To simulate the multiaxial loading scenario of a stented coronary artery, we developed the testing device ‘LAESIO’ that can measure differences in the stress-stretch behavior of the arterial wall before and after the indentation of a strut-like stamp. The testing protocol was optimized according to preliminary experiments, more specifically equilibrium and relaxation tests. After chemical fixation of the specimens and subsequent tissue clearing, we performed three-dimensional surface and second-harmonic generation scans on the deformed specimens. We analyzed and correlated the mechanical response with structural parameters of high-affected tissue located next to the stamp indentation and low-affected tissue beyond the injured area. The results reveal that damage mechanisms, like tissue compression as well as softening, fiber dispersion, and the lesion extent, are direction-dependent, and the severity of them is linked to the strut orientation, indentation pressure, and position. The findings highlight the need for further investigations by applying the proposed methods to human coronary arteries. Additional data and insights might help to incorporate the observed damage mechanisms into material models for finite element analyses to perform more accurate simulations of stent-implantations. KW - Percutaneous coronary intervention KW - Stent KW - Mechanical properties KW - Damage mechanism KW - Vascular injury KW - Coronary artery KW - Indentation test KW - Softening KW - Second-harmonic generation imaging KW - Micro-structure Y1 - 2020 U6 - https://doi.org/10.1016/j.actbio.2020.08.016 VL - 116 IS - October SP - 285 EP - 301 PB - Elsevier ER - TY - CHAP A1 - Wiesent, Lisa A1 - Geith, Markus A. A1 - Wagner, Marcus T1 - Simulation of Fluid-Structure Interaction between injection medium and balloon catheter using ICFD T2 - 11th European LS-DYNA Conference 2017, 9 - 11 May, Salzburg, Austria N2 - Arteriosclerosis is a major health issue worldwide. While it is commonly treated by the implantation of an balloon-expandable stent, micro injuries may occur during stent deployment, and induce in-stent restenosis, whose consequence can be fatal. Studying this undesirable phenomenon is usually limited as experimental data is hard to obtain on ethical ground. Numerical simulation are performed to better understand this problem. To construct a more realistic simulation of a balloon-expandable stent, a partitioned strongly-coupled FSI simulation of the balloon deployment was set up using the ICFD solver of LS-DYNA, - a quite innovative approach. The complex balloon configuration as well as the interaction of the injection medium and the balloon structure was considered. The balloon structure consisting of shell elements was obtained from preliminary balloon folding and pleating simulations. The balloon consists of a flexible thin walled polyamide. The injection fluid is implemented using volume elements. Balloon deployment was initiated by a pressure boundary condition inducing a volume flow into the balloon. The initial feasibility analysis showed promising result including a continuous balloon deployment and a reasonable development of the fluid pressure and velocity field. However, applying this FSI approach to a more complex balloon structure led to a non convergent solution. The non-convergence could be mainly reduced to mechanical factors including the low wall thickness of the balloon (< 0.05 mm) and the flexibility of the polyamide. Further, the ICFD solver shows less accuracy concerning the FSI conditions when dealing with thin flexible structures as well as enclosed volumes. A shell thickness of 0.06 mm is believed to result in a convergent solution. KW - Koronare Herzkrankheit KW - Stent KW - Ballondilatation KW - Numerische Strömungssimulation Y1 - 2017 UR - https://www.dynalook.com/conferences/11th-european-ls-dyna-conference/icfd-solver-and-fsi/simulation-of-fluid-structure-interaction-between-injection-medium-and-balloon-catheter-using-icfd SN - 978-3981621549 ER - TY - GEN A1 - Wiesent, Lisa A1 - Hupke, Constantin A1 - Balk, Christian A1 - Schultheiss, Ulrich A1 - Schratzenstaller, Thomas T1 - Optimization of the cardiovascular stent design towards improved expansion behaviour and radial stiffness properties T2 - Biomedizinische Technik N2 - - Development of a FEA Tool for a realistic stent simulation - investigation on minor modification on the stent design on the expansion behaviour - analysis of three stent designs: classical stent design with pronounced dogbone effect, two modified stent design (non-dogbone-design) KW - Kardiovaskuläres System KW - Stent Y1 - 2018 U6 - https://doi.org/10.1515/bmt-2018-6031 VL - 63 IS - s1 ER - TY - GEN A1 - Geith, Markus A. A1 - Swidergal, Krzysztof A1 - Schratzenstaller, Thomas A1 - Holzapfel, Gerhard A. A1 - Wagner, Marcus T1 - Numerical analysis of stent delivery systems during pre- and intraoperative processes T2 - 15. Deutsches LS-DYNA Forum, 15.-17.10.2018, Bamberg Y1 - 2018 UR - https://www.researchgate.net/publication/335260823_Numerical_analysis_of_stent_delivery_systems_during_pre-_and_intraoperative_processes ER -