TY - CHAP A1 - Briem, Ulrich ED - Dohm, Martin T1 - Fatigue Behaviour of Rope Wires T2 - Proceedings of the OIPEEC Conference, La Rochelle, France, 12th - 15th March 2019 N2 - The rope curve line of a tensioned rope can be described by means of the catenary curve. Opposed to that, the curved line of a free bent rope cannot be described by an analytical function. Practical applications of free bending are for example at tail ropes at the bottom of shaft in rope drives with traction sheaves. The question whether the maximum diameter of rope loop is small enough for the diameter of the shaft is highly interesting. In [1] a method was presented to calculate the curved line of free bent ropes numerically by help of energy methods. An analytical description of rope curve line would be very helpful. Beginning with the structure of a rope curve line of tensioned rope (catenary curve) and considering the influence of bending stiffness, the structure of an analytical equation for the curve line of a free bent rope will be developed. The main focus of this paper is to develop and to describe the structure of such an analytical equation. To get a first idea about the values of the constants in that analytical equation a few test results were evaluated. But these equations consider the static rope behavior only. Due to dynamic effects in the rope while running through the loop at the bottom of a shaft, pendulousness of the tail rope occurs. Y1 - 2019 UR - https://oipeec.org/products/mathematical-approach-to-curve-line-of-free-bent-ropes PB - OIPEEC ER - TY - CHAP A1 - Briem, Ulrich ED - Dohm, Martin T1 - Mathematical Approach to Curve Line of free bent Ropes T2 - Proceedings of the OIPEEC Conference, La Rochelle, France, 12th - 15th March 2019 N2 - The rope curve line of a tensioned rope can be described by means of the catenary curve. Opposed to that, the curved line of a free bent rope cannot be described by an analytical function. Practical applications of free bending are for example at tail ropes at the bottom of shaft in rope drives with traction sheaves. The question whether the maximum diameter of rope loop is small enough for the diameter of the shaft is highly interesting. In [1] a method was presented to calculate the curved line of free bent ropes numerically by help of energy methods. An analytical description of rope curve line would be very helpful. Beginning with the structure of a rope curve line of tensioned rope (catenary curve) and considering the influence of bending stiffness, the structure of an analytical equation for the curve line of a free bent rope will be developed. The main focus of this paper is to develop and to describe the structure of such an analytical equation. To get a first idea about the values of the constants in that analytical equation a few test results were evaluated. But these equations consider the static rope behavior only. Due to dynamic effects in the rope while running through the loop at the bottom of a shaft, pendulousness of the tail rope occurs. KW - Bending Stiffness KW - Catenary KW - Free Bending KW - Rope Curvature KW - Tail Ropes Y1 - 2019 UR - https://oipeec.org/products/mathematical-approach-to-curve-line-of-free-bent-ropes PB - OIPEEC ER - TY - CHAP A1 - Buschmann, Knut A1 - Briem, Ulrich ED - Dohm, Martin T1 - Ultra Deep Temperature Behaviour of Wire Rope and Rope Wires T2 - Proceedings of the OIPEEC Conference, La Rochelle, France, 12th - 15th March 2019 N2 - Mobile cranes are regularly operated in regions which experience ultra deep operating temperatures of down to -60?C (-76?F). In safety regulated work environments crane operations will be suspended simply because the lowest wire rope working temperature stated in the applicable standards is -40?C/F. Examples of ultra deep temperature wire rope application are shown in Figure 1.1 and 1.3. It should be noted that this paper is written in conjunction with a paper written by the co-author Ulrich Briem titled “Fatigue Behaviour of Rope Wires”, presented and published in unison with this one. In order to analyze the behaviour under ultra deep temperature conditions, tests on wire rope as well as on rope wires were carried out. In the following, static tensile and bending test results with rope and rope wires will be reported, which were carried out in conditions of down to -95?C (-139?F) as well as at room temperature. The conclusion is that the results of these tests can be adopted to crane wire rope as well. Y1 - 2019 UR - https://oipeec.org/products/ultra-deep-temperature-behaviour-of-wire-rope-and-rope-wires ER - TY - JOUR A1 - Lang, A. A1 - Monkman, Gareth J. T1 - An analysis of the electrical capacitance between two conducting spheres JF - Journal of Electrostatics N2 - Many modern composites consist of dielectric polymer matrices containing embedded spherical particles. These particles can be electrically conducting and often have magnetic properties. In order to accurately model and simulate such materials, precise calculation of the electrical capacitance between identically sized spheres is required. This is of particular relevance at microscopic dimensions where many smart material-based micro devices are concerned. This may appear trivial for a small number of particles. However, many methods or their analysis appear to be questionable or not applicable at reduced dimensions. In this work, the various methods of analysis are scrutinized before being compared with both simulation and direct measurements. It is surprising to note that of the many works investigated only 3 are in close agreement with both simulation and measurement. Graphical abstract This paper deals with the precise calculation of the electrical capacitance between two conducting spheres of equal, or near equal size.The calculations have been verified by both experimental measurements and simulation. Algorithms in MatLab (Octave) format have been included in the supporting information. KW - Capacitance between spheres KW - Calculation KW - Simulation Experiment Y1 - 2020 U6 - https://doi.org/10.1016/j.elstat.2020.103518 VL - 108 PB - Elsevier ER - TY - JOUR A1 - Chen, Rui A1 - Zhang, Zhuo A1 - Song, Ruizhou A1 - Fang, Cheng A1 - Sindersberger, Dirk A1 - Monkman, Gareth J. A1 - Guo, Jianglong T1 - Time-dependent electroadhesive force degradation JF - Smart Materials and Structures N2 - This paper concerns a comprehensive investigation of time-dependent electroadhesion (EA) force degradation. EA shear force tests on different object materials (a PET, glass, ABS, and wood plate) have shown that force degradation was dominated by residual polarization charges trapped in the EA pad dielectric rather than in the substrate dielectric from which the object to be prehended is made. In order to explain this dynamic physical phenomenon, a model of dielectric polarization and depolarization has been proposed. According to the derived relationship between EA force and discharge time, three different methods intended to mitigate this problem has been compared: (1) the natural discharge method, (2) the high voltage resistor discharge method, and (3) the discharge prior to field polarity reversal method. These methods are useful for generating repeatable and stable EA forces, which are required for the characterization of EA pads and their subsequent employment in material handling, mobile robot crawling and climbing tasks. Y1 - 2020 U6 - https://doi.org/10.1088/1361-665X/ab79b5 VL - 29 IS - 5 PB - IOP Publishing ER - TY - JOUR A1 - Sorokin, Vladislav V. A1 - Stepanov, Gennady V. A1 - Shamonin (Chamonine), Mikhail A1 - Monkman, Gareth J. A1 - Kramarenko, Elena Yu T1 - Magnetorheological behavior of magnetoactive elastomers filled with bimodal iron and magnetite particles JF - Smart materials and structures N2 - Magnetoactive elastomers (MAE) based on soft silicone matrices, filled with various proportions of large diameter ( approximately 50 mu m) iron and small diameter ( approximately 0.5 mu m) magnetite particles are synthesized. Their rheological behavior in homogeneous magnetic fields up to 600 mT is studied in detail. The addition of small magnetite particles facilitates fabrication of uniformly distributed magnetic elastomer composites by preventing aggregation and sedimentation of large particles during curing. It is shown that using the proposed bimodal filler particles it is possible to tailor various magnetorheological (MR) properties which can be useful for different target applications. In particular, either absolute or relative magnetorheological effects can be tuned. The value of the damping factor as well as the range of deformation amplitudes for the linear viscoelastic regime can be chosen. The interdependencies between different MR properties of bimodal MAEs are considered. The results are discussed in the model framework of particle network formation under the simultaneous influence of external magnetic fields and mechanical deformation. KW - damping factor KW - DAMPING PROPERTIES KW - FIELD KW - HYDROGELS KW - MAGNETOELASTIC BEHAVIOR KW - Magnetorheological effect KW - magnetorheological elastomer KW - mechanical hysteresis KW - Payne effect Y1 - 2017 U6 - https://doi.org/10.1088/1361-665X/26/3/035019 VL - 26 IS - 3 PB - IOP Publishing ER - TY - GEN A1 - Reindl, Andrea A1 - Eriksson, Lars A1 - Niemetz, Michael A1 - Sangyoung, Park A1 - Meier, Hans T1 - Control Concepts for a Decentralized Battery Management System Decentralized Battery Management System Global Control Level T2 - 16th International Renewable Energy Storage Conference (IRES2022), 20 to 22 September 2022, Düsseldorf Y1 - 2022 UR - https://www.researchgate.net/publication/363769042_Control_Concepts_for_a_Decentralized_Battery_Management_System_Decentralized_Battery_Management_System_Global_Control_Level PB - Eurosolar ER - TY - CHAP A1 - Körner, Patrick A1 - Reindl, Andrea A1 - Meier, Hans A1 - Niemetz, Michael T1 - A Theoretical Comparison of Different Virtual Synchronous Generator Implementations on Inverters T2 - 2022 24th European Conference on Power Electronics and Applications (EPE'22 ECCE Europe): 05-09 September 2022, Hannover, Germany N2 - The goal to overcome the global climate crisis leads to a rising demand for the usage of Renewable Energy Sources (RES). Decentralized control strategies are needed to allow the integration of RES into the grid. The Virtual Synchronous Generator (VSG) is proposed as a method to add virtual inertia to the grid by emulating the rotating mass of a Synchronous Generator (SG) on the control algorithm of an inverter. This paper presents the VSG control structure as well as the mathematical description in a unified form. Due to the fact that classical droop control can be seen as a special form of the VSG, their correlation is highlighted by evaluating the steady state output characteristics of the inverter. Furthermore, a theoretical comparison between different VSG topologies, including the VISMA-Method 2 and the synchronverter, is given. In order to achieve better voltage stability, principles to add virtual impedance to the inverter's output are described. Y1 - 2022 UR - https://ieeexplore.ieee.org/document/9907497 PB - IEEE ER - TY - CHAP A1 - Paredes, Marcelo A1 - Keim, Vincent A1 - Nonn, Aida A1 - Wierzbicki, Tomasz T1 - Effect of plasticity parameter on the crack propagation in steel pipelines T2 - Proceedings of the conference on Technology for future and ageing piplines, Ghent, Belgium Y1 - 2018 ER - TY - JOUR A1 - Haug, Sonja A1 - Vetter, Miriam A1 - Weber, Karsten T1 - Gebäudesanierung zwischen Energieeffizienz und Sozialverträglichkeit BT - Zwei empirische Fallstudien JF - TATuP - Zeitschrift für Technikfolgenabschätzung in Theorie und Praxis N2 - Die Akzeptanz unter Bewohnern und Bewohnerinnen gewinnt bei hoch komplexen, technisch anspruchsvollen energetischen Sanierungen als „Innovationsmotor“ zunehmend an Relevanz. Der Beitrag basiert auf zwei Fallstudien zur partizipativen Nutzereinbindung bei energetischen Sanierungen im genossenschaftlichen Wohnbau historischer Stadtquartiere in Regensburg. Neben einer sozialverträglichen Sanierung wurde jeweils ein hohes Maß an Energieeffizienz bei den technischen Lösungen ange-strebt. Haushaltsbefragungen und qualitative Interviews zeigen die hohe Akzeptanz von Sanierungsmaßnahmen, sofern die Senkung der Energiekosten die erhöhte Miete kompensiert. Abschließend werden Akzeptanzfaktoren wie Partizipation, Vertrauen, Sozialverträglichkeit und Autarkie erörtert. T2 - Building restoration between energy efficiency and user acceptance KW - Altbaumodernisierung KW - Energieeinsparung KW - Sozialverträglichkeit KW - Fallstudie KW - energy-efficient building restoration KW - user acceptance KW - household survey KW - historic quarter KW - renewable energy Y1 - 2020 U6 - https://doi.org/10.14512/tatup.29.3.56 SN - 2567-8833 VL - 29 IS - 3 SP - 56 EP - 63 PB - oekom-Verlag ER -