TY - JOUR A1 - Zagler, Andreas A1 - Landgraf, Ferdinand A1 - Rück, Thomas A1 - Bierl, Rudolf T1 - Entwicklung eines mikromechanischen kapazitiven Schalldetektors im resonanten Betrieb für die photoakustische Spurengasanalyse JF - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München Y1 - 2017 PB - VDE-Verlag CY - Berlin ER - TY - CHAP A1 - Gaida, Peter A1 - Weigl, Stefan A1 - Rück, Thomas A1 - Bierl, Rudolf T1 - Portable photoakustische Messeinheit zur NO2 Detektion im Spurenbereich T2 - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München Y1 - 2017 SN - 978-3-8007-4491-6 PB - VDE-Verlag CY - Berlin ER - TY - CHAP A1 - Fischer, Johannes T1 - Miniaturisierter plasmonischer Sensor für das Monitoring von Weichmachern in Gewässerproben T2 - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München Y1 - 2017 SN - 978-3-8007-4491-6 PB - VDE-Verlag CY - Berlin ER - TY - GEN A1 - Hausler, Peter A1 - Roth, Carina A1 - Vitzthumecker, Thomas A1 - Fischer, Johannes A1 - Bierl, Rudolf T1 - Motionless SPR-angle scan with a miniaturized device T2 - Europtrode XIV, Naples, 25-28 March 2018 Y1 - 2018 ER - TY - CHAP A1 - Weigl, Stefan A1 - Gaida, Peter A1 - Rück, Thomas A1 - Bierl, Rudolf T1 - Portable Measurement Unit for NO2 Trace Gas Detection T2 - PHOTOPTICS 2018, 6th International Conference on Photonics, Optics and Laser Technology, 25 - 27 January 2018, Funchal Madeira Y1 - 2018 ER - TY - RPRT A1 - Unger, J. A1 - Rück, Thomas A1 - Landgraf, Ferdinand A1 - Bierl, Rudolf T1 - Herstellung und Analyse der Resonanzfrequenz eines MEMS Cantilever für das CEPAS Verfahren N2 - Diese Abhandlung beschreibt das Konzept eines mikroeletromechanischen Systems (MEMS), das im Messverfahren der cantilever enhanced photoacoustic spectroscopy (CEPAS) Verwendung finden soll. Es wird die Herstellung eines einseitig eingespannten Biegebalkens aus Silizium mittels deep reactiv ion etching (DRIE) beschrieben. Des Weiteren wird die Resonanzfrequenz dieses Cantilevers mit Hilfe Laservibrometertechnik untersucht. Die resultierenden resonanten Schwingungen 0.Ordnung werden mit den Ergebnissen einer vereinfachten theoretischen Näherung verglichen. Die Messergebnisse stehen in gutem Zusammenhang mit den theoretischen Werten. Solche Cantilever, die aus silicon on insula tor (SOI) Wafer angefertigt wurden, weisen bei einer Zielfrequenz ein mittlere Abweichung von Δf = 118±26Hz (bzw.Δf =0,76±0,17%) auf. Y1 - 2015 ER - TY - CHAP A1 - Holler, Sven A1 - Hausler, Peter A1 - Roth, Carina A1 - Bierl, Rudolf T1 - Gestapelte Au-Al-Au und Au-Ag-Au Schichten als aktive Schichten für die Oberflächenplasmonenresonanzspektroskopie T2 - 5. Landshuter Symposium Mikrosystemtechnik, März 2016 Y1 - 2016 SN - 978-3-9812696-9-7 SP - 192 EP - 198 PB - Fachhochschule Landshut CY - Landshut ER - TY - CHAP A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf T1 - Einbindung eines CMOS-Detektors in einen hochintegrierten SPR-Sensor T2 - 5. Landshuter Symposium Mikrosystemtechnik, März 2016 Y1 - 2016 SN - 78-3-9812696-9-7 SP - 200 EP - 205 PB - Fachhochschule Landshut CY - Landshut ER - TY - JOUR A1 - Romano, Marco A1 - Micklitz, Matthias A1 - Olbrich, Florian A1 - Bierl, Rudolf A1 - Ehrlich, Ingo A1 - Gebbeken, Norbert T1 - Experimental investigation of damping properties of unidirectionally and fabric reinforced plastics by the free decay method JF - Journal of Achievements in Materials and Manufacturing Engineering N2 - Purpose: of this paper is experimental investigation of damping properties of unidirectionally and fabric reinforced plastics by the free decay method. Design/methodology/approach: For the evaluation of the presumed effect experimental structural dynamic investigations comparing unidirectionally and fabric reinforced plastics are carried out. In detail the free decay behaviour of flat beamlike specimens under fixed-free boundary conditions and relatively constant and reproducible displacement excitation is investigated. Findings: The vibrating structure has been measured by a laser scanning vibrometer PSV 400 from POLYTEC. In both cases evaluation of the results yields enhanced damping properties of the specimens with fabric reinforcement compared to the unidirectionally reinforced specimens. The results justify the presumed acting of a mesomechanic kinematic. Research limitations/implications: The results show that in either case the material damping in terms of the logarithmic decrement of the fabric reinforced material is higher than the material damping in of the unidirectionally reinforced material. Additionally, when the fabric reinforced specimens are addressed, in each case the plain weave reinforced specimens exhibited higher values of the material damping as the twill weave 2/2 reinforced ones. Originality/value: Ondulations in fabrics as a textile semi-finished product are caused by the alternating crossing of warp and fill yarns. In the mesoscopic scale the acting of a mesomechanic kinematic is presumed to enhance the damping properties under cyclic elastic deformation. For the evaluation of the presumed effect experimental structural dynamic investigations comparing unidirectionally and fabric reinforced plastics are carried out. KW - structural vibration KW - damping KW - fibre reinforced plastics KW - mesomechanic scale KW - fabric reinforced layer Y1 - 2014 VL - 63 IS - 2 SP - 65 EP - 80 ER - TY - CHAP A1 - Jobst, Simon A1 - Bierl, Rudolf T1 - A Comparison of Correlation and Zero-Crossing Based Techniques in Ultrasonic Measurement T2 - 10th International Symposium on Applied Reconfigurable Computing (ARC'2014), Vilamoura, Algarve, Portugal, 14 - 16 April, 2014 N2 - Ultrasound measurement technology has advancedin previous decades due to positive developments in computing power and lower cost for the necessary hardware. Correlation-based processing can be advantageous for high-accuracy measurements, especially in noisy environments. Higher computational load makes correlation less attractive for industrialapplications, though, favouring traditional processing techniques. A platform for comparing various processing techniques hasbeen developed. It was found that both zero-crossing detectionas well as correlation can achieve very high accuracy over a hightemperature range but that correlation-based processing can lead to a significant precision bias depending on system bandwidth. Y1 - 2014 ER - TY - CHAP A1 - Hofmann, Matthias A1 - Bierl, Rudolf A1 - Rück, Thomas T1 - Implementation of a dual-phase lock-in amplifier on a TMS320C5515 digital signal processor T2 - Proceedings of the 5th European DSP Education and Research Conference (EDERC), 13-14 Sept. 2012, Amsterdam N2 - A digital dual-phase lock-in amplifier that is capable to run on a low-cost, low-power platform comprising a 16-bit fixed-point digital signal processor was developed. This is achieved by a set of optimised digital filters including an exponential averager to adjust the time constant of the overall filter. The reference frequency is generated using a direct digital synthesis source utilising angle decomposition with a resolution of 1 Hz. The digital lock-in algorithm is described and the performance of the algorithm is analysed. The experimental results show that the developed lock-in amplifier achieves similar performance to a commercially available lock-in amplifier. Y1 - 2012 U6 - https://doi.org/10.1109/EDERC.2012.6532217 ER -