TY - JOUR A1 - van der Weerd, Bastiaan A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Trends in Electrochemical Sensing of Blood Gases JF - Bioanalytical Reviews N2 - The monitoring of partial pressures of the blood gases carbon dioxide (pCO2) and oxygen (pO2) is of great importance in clinical diagnostics. The measure of pCO2 and pO2 provides essential information about the patient’s metabolism, gas exchange, ventilation, and acid–base homeostasis. The conventional electrochemical methods for clinical blood gas analysis are based on the potentiometric Severinghaus sensor for carbon dioxide and the amperometric Clark sensor for oxygen. These techniques are well established and are only shortly discussed in this overview. However, in recent years a variety of modifications of these classical sensor concepts and new approaches of electrochemical sensing of pCO2 and pO2 have been introduced. This review summarizes recent developments in this field and discusses the potential for future applications in clinical blood gas analysis. KW - Blood gas analysis KW - Noninvasive blood gas sensor KW - Electrochemical sensor KW - Clinical analysis Y1 - 2016 U6 - https://doi.org/10.1007/11663_2016_1 VL - 6 SP - 263 EP - 280 PB - Springer CY - Berlin ER - TY - CHAP A1 - Rück, Thomas A1 - Läpple, I. A1 - Bierl, Rudolf T1 - Photoakustische Spurengasanalytik von NO2 im ppt-Bereich (10^-12) bei Verwendung kostengünstiger Einzelkomponenten T2 - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München KW - Elektroniksystem KW - Industrie 4.0 KW - Mikrosystemtechnik KW - Mikrofluidik KW - Mikroaktorik Y1 - 2017 SN - 978-3-8007-4491-6 PB - VDE-Verlag CY - Berlin ER - TY - JOUR A1 - Zagler, Andreas A1 - Landgraf, Ferdinand A1 - Rück, Thomas A1 - Bierl, Rudolf T1 - Entwicklung eines mikromechanischen kapazitiven Schalldetektors im resonanten Betrieb für die photoakustische Spurengasanalyse JF - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München Y1 - 2017 PB - VDE-Verlag CY - Berlin ER - TY - CHAP A1 - Gaida, Peter A1 - Weigl, Stefan A1 - Rück, Thomas A1 - Bierl, Rudolf T1 - Portable photoakustische Messeinheit zur NO2 Detektion im Spurenbereich T2 - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München Y1 - 2017 SN - 978-3-8007-4491-6 PB - VDE-Verlag CY - Berlin ER - TY - CHAP A1 - Fischer, Johannes T1 - Miniaturisierter plasmonischer Sensor für das Monitoring von Weichmachern in Gewässerproben T2 - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München Y1 - 2017 SN - 978-3-8007-4491-6 PB - VDE-Verlag CY - Berlin ER - TY - GEN A1 - Hausler, Peter A1 - Roth, Carina A1 - Vitzthumecker, Thomas A1 - Fischer, Johannes A1 - Bierl, Rudolf T1 - Motionless SPR-angle scan with a miniaturized device T2 - Europtrode XIV, Naples, 25-28 March 2018 Y1 - 2018 ER - TY - CHAP A1 - Weigl, Stefan A1 - Gaida, Peter A1 - Rück, Thomas A1 - Bierl, Rudolf T1 - Portable Measurement Unit for NO2 Trace Gas Detection T2 - PHOTOPTICS 2018, 6th International Conference on Photonics, Optics and Laser Technology, 25 - 27 January 2018, Funchal Madeira Y1 - 2018 ER - TY - RPRT A1 - Unger, J. A1 - Rück, Thomas A1 - Landgraf, Ferdinand A1 - Bierl, Rudolf T1 - Herstellung und Analyse der Resonanzfrequenz eines MEMS Cantilever für das CEPAS Verfahren N2 - Diese Abhandlung beschreibt das Konzept eines mikroeletromechanischen Systems (MEMS), das im Messverfahren der cantilever enhanced photoacoustic spectroscopy (CEPAS) Verwendung finden soll. Es wird die Herstellung eines einseitig eingespannten Biegebalkens aus Silizium mittels deep reactiv ion etching (DRIE) beschrieben. Des Weiteren wird die Resonanzfrequenz dieses Cantilevers mit Hilfe Laservibrometertechnik untersucht. Die resultierenden resonanten Schwingungen 0.Ordnung werden mit den Ergebnissen einer vereinfachten theoretischen Näherung verglichen. Die Messergebnisse stehen in gutem Zusammenhang mit den theoretischen Werten. Solche Cantilever, die aus silicon on insula tor (SOI) Wafer angefertigt wurden, weisen bei einer Zielfrequenz ein mittlere Abweichung von Δf = 118±26Hz (bzw.Δf =0,76±0,17%) auf. Y1 - 2015 ER - TY - CHAP A1 - Holler, Sven A1 - Hausler, Peter A1 - Roth, Carina A1 - Bierl, Rudolf T1 - Gestapelte Au-Al-Au und Au-Ag-Au Schichten als aktive Schichten für die Oberflächenplasmonenresonanzspektroskopie T2 - 5. Landshuter Symposium Mikrosystemtechnik, März 2016 Y1 - 2016 SN - 978-3-9812696-9-7 SP - 192 EP - 198 PB - Fachhochschule Landshut CY - Landshut ER - TY - CHAP A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf T1 - Einbindung eines CMOS-Detektors in einen hochintegrierten SPR-Sensor T2 - 5. Landshuter Symposium Mikrosystemtechnik, März 2016 Y1 - 2016 SN - 78-3-9812696-9-7 SP - 200 EP - 205 PB - Fachhochschule Landshut CY - Landshut ER -