TY - GEN A1 - Raptis, Georgios T1 - Biometrie - Anwendungen und Datenschutz. Welche Zusatzinformationen liefert der IRIS-Pförtner? Nebennutzen in einem biometrischen Zugangskontrollsystem. Medizinische Hintergründe. Symposium des Bundesamtes für Sicherheit in der Informationstechnik, Vortrag, Darmstadt 23. Mai 2002 BT - Vortrag, Darmstadt 23. Mai 2002 T2 - Symposium des Bundesamtes für Sicherheit in der Informationstechnik Y1 - 2002 ER - TY - JOUR A1 - Lekakis, J. A1 - Nanas, J. A1 - Prassopoulos, V. A1 - Raptis, Georgios T1 - Cardiac I-123 metaiodobenzylguanidine uptake in predicting early and late mortality in patients with congestive heart failure JF - Circulation (Suppl.) KW - Stauungssuffizienz KW - Radiologische Diagnostik KW - Prognose Y1 - 1997 VL - 96 IS - 8 SP - 2104 ER - TY - JOUR A1 - Horn, Lars-Christian A1 - Fischer, Uta A1 - Tannapfel, A. A1 - Kuhn, H. A1 - Hänel, C. A1 - Raptis, Georgios T1 - The role of p53 tumorsuppressorgene in tumor progression in cervical cancer JF - Pathology - Research and Practice KW - Tumorsuppressor-Gen KW - Tumorwachstum KW - Gebärmutterhalskrebs Y1 - 1999 VL - 195 SP - 328 ER - TY - RPRT A1 - Schenkel, Johannes A1 - Albert, Jürgen A1 - Raptis, Georgios T1 - Arbeitskonzept Notfalldatenmanagement KW - Elektronische Gesundheitskarte KW - Notfallmedizin Y1 - 2011 UR - www.bundesaerztekammer.de/downloads/Arbeitskonzept_NFDM_1.051.pdf ER - TY - THES A1 - Raptis, Georgios T1 - Vertraulichkeit von medizinischen Daten in der Telematik-Infrastruktur - Sicherheitsanalyse unter Berücksichtigung von Aspekten der langfristigen Sicherheit KW - Medizinische Dokumentation KW - Telekommunikation KW - Datensicherheit Y1 - 2008 CY - Heidelberg ER - TY - GEN A1 - Raptis, Georgios T1 - Mechanismen und Einsatzkonzepte von Heilberufsausweis und elektronischer Gesundheitskarte BT - Vortrag T2 - Oberseminar im Fachbereich Informatik, Kryptographie und Computeralgebra der TU-Darmstadt, 28.11.2006 KW - Elektronische Gesundheitskarte KW - Heilberuf KW - Ausweis Y1 - 2006 ER - TY - JOUR A1 - Höh, H. A1 - Gamael, A. A1 - Raptis, Georgios T1 - Energie und Phakozeit bei Ultraschall und Laserphakoemulsifikation JF - Klinische Monatsblätter für Augenheilkunde KW - Phakoemulsifikation KW - Ultraschall Y1 - 2000 VL - 217 IS - Suppl. 8 SP - 5 ER - TY - GEN A1 - Raptis, Georgios T1 - Einsatzmöglichkeiten des elektronischen Heilberufsausweises BT - Vortrag im Rahmen des CAST-Forums, Fraunhofer IGD, 14.09.2006 T2 - CAST-Forums, Fraunhofer IGD, 14.09.2006 KW - Heilberuf KW - Ausweis Y1 - 2006 ER - TY - JOUR A1 - Hornberger, Helga A1 - Marquis, Peter M. A1 - Christiansen, Silke H. A1 - Strunk, Horst P. T1 - Microstructure of a high strength alumina glass composite JF - Journal of Materials Research N2 - The morphology and microstructure of an Al2O3 glass composite (trade name In-Ceram, Vita Zahnfabrik) were studied using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The composite was produced by infiltration of a lanthanum-based glass throughout a porous Al2O3 body. This alumina body was formed by three classes of particles differing in size and shape: faceted particles typically ≤4 μm in diameter, platelets of average diameter 8 μm, 1.5 μm thickness, and small spheres 0.4 μm in diameter. The outstanding strength properties of the composite (600 MPa, ball-on-ring test) are a result of the high wetting capability of the glass phase on the Al2O3 surface. In addition, plastic strain relaxation in the faceted particles by dislocation formation compensates partially for residual stresses and impedes crack formation at the glass/Al2O3 interface. Y1 - 1996 U6 - https://doi.org/10.1557/JMR.1996.0104 VL - 11 IS - 4 SP - 855 EP - 858 ER - TY - PAT A1 - Hornberger, Helga A1 - Thiel, Norbert A1 - Vollmann, Markus T1 - Fully ceramic tooth replacement with a frame made of cer-stabilised zircon-oxide N2 - Vollkeramischer Zahnersatz mit einem Gerüst, das aus einem Gerüstmaterial aus einem Cer-stabilisierten Zirkonoxid (Ce-ZrO2) mit einem Anteil von bis zu 25 Gew% Aluminiumoxid (Al2O3) bezogen auf den Anteil an ZrO2 aufgebaut ist und einem Infiltrationsglasanteil im Gerüst von 0-40 Vol% bezogen auf das Volumen des Gerüsts sowie einer auf das Gerüstmaterial abgestimmten Verblendkeramik.Die Erfindung betrifft die Verwendung von cer-stabilisiertem ZrO2 zur Herstellung von Gerüstmaterialien, die als Restauration im Dentalbereich einsetzbar sind. T2 - Vollkeramischer Zahnersatz mit einem Gerüst aus einem cer-stabilisierten Zirkonoxid Y1 - 2002 UR - https://depatisnet.dpma.de/DepatisNet/depatisnet?action=bibdat&docid=WO002002047616A3 ER - TY - JOUR A1 - Gebhardt, F. A1 - Seuss, Sigrid A1 - Turhan, Metehan C. A1 - Hornberger, Helga A1 - Virtanen, Sannakaisa A1 - Boccaccini, Aldo R. T1 - Characterization of electrophoretic chitosan coatings on stainless steel JF - Materials Letters N2 - Electrophoretic chitosan deposits on stainless steel AISI 316 L were produced and characterized. The coating quality (thickness, defectiveness, corrosion protection ability) was seen to depend on the electric field used for EPD. Corrosion studies in concentrated simulated body fluid (SBF5) demonstrated that the surface characteristics of AISI 316 L can be positively influenced by the chitosan coating. KW - Chitosan KW - Electrophoretic deposition KW - Biomaterials KW - Electrochemistry Y1 - 2012 U6 - https://doi.org/10.1016/j.matlet.2011.08.088 VL - 66 IS - 1 SP - 302 EP - 304 ER - TY - PAT A1 - Aechtner, Stefan A1 - Hornberger, Helga A1 - Nagel, Emil A1 - Thiel, Norbert T1 - Composite material and method for the preparation thereof N2 - A composite material with a porous inorganic-nonmetallic matrix and a second material, characterized in that said porous inorganic-nonmetallic matrix has a bending strength of >=40 MPa as measured according to ISO 6 872; said second material is an organic material which at least partly fills the pores of said porous matrix; and said composite material has a modulus of elasticity, E, of >=25 GPa as measured according to ISO 10 477. Y1 - 2001 UR - https://depatisnet.dpma.de/DepatisNet/depatisnet?action=bibdat&docid=US020090001623A1 ER - TY - PAT A1 - Muerrle, Ulrich A1 - Hornberger, Helga T1 - Method of making a ceramic restoration N2 - Production of a dental reconstruction comprises: (a) forming a mold (12) from a model (10); (b) using (12) to make an isotropically heat-expandable replica from a ceramic precursor (14); (c) oxidizing (14) to produce an enlarged ceramic replica; (d) forming a silicone mold from this replica; (e) using (d) to make a second ceramic replica; and (f) sintering the second replica with volume reduction to form a replica identical to (10). T2 - Verfahren zur Herstellung einer Zahnrestauration aus Keramik Y1 - 2003 UR - https://depatisnet.dpma.de/DepatisNet/depatisnet?action=bibdat&docid=EP000001346702A1 ER - TY - JOUR A1 - Hornberger, Helga A1 - Marquis, Peter M. A1 - Franks, J. T1 - The impact of diamond-like coatings on the strength of dental ceramics JF - Journal of Dental Research Y1 - 1995 VL - 74 SP - 522 ER - TY - JOUR A1 - Hornberger, Helga A1 - Marquis, Peter M. T1 - Mechanical properties and microstructure of In-Ceram BT - a ceramic-glass composite for dental crowns JF - Glastechnische Berichte - Glass Science and Technology Y1 - 1995 VL - 68 IS - 6 SP - 188 EP - 194 ER - TY - JOUR A1 - Manaranche, Claire A1 - Hornberger, Helga T1 - A proposal for the classification of precious dental alloys according to their resistance to corrosion based on the iso 10271 standard JF - European Cells and Materials N2 - A lot of dental alloys are available on the market. Among these alloys, there are the conventional alloys, the so called casting alloys used without ceramics, the bonding alloys used with high fusing ceramics and the universal alloys used without or with low fusing ceramics. It is im portant to know the physical and mechanical properties of these materials but also their biocompatibility and their resistance to corrosion. Dental alloys are generally placed in the mouth for many years, they must not induce adverse biological reactions such as gingival swelling and erythema, mucosal pain and lichenoid reactions. Although these troubles are often caused not by the materials itself (1, 2), they can be induced by the metallic ions released during their corrosion. In order to decrease the risks to the health, it is necessary to study the corrosion of the dental alloys. Currently, the ISO 10271 Standard (3), describes 3 different corrosion tests: a static immersion test (chemical corrosion), an electrochemic al test and a tarnish test. However, there are no indications yet about the possible interpretation of test results. In this paper, we propose a method to compare and classify the dental alloys in relation to their chemical and electrochemical corrosion results. METHODS: The material tested are pure metals such as gold, palladium, silver, copper and zinc as well as dental alloys which are commercially sold (see Table 1). 54 different materials have been tested. A minimum of four samples of each material were tested by electrochemic al corrosio n and a minimum of three in chemical test. The samples were cast and prepared as indicated by the manufacturer and by the ISO 10271. For the electrochemical test, the samples are in the form of disks 11 mm in diameter. They are tested with a potentiostat/galvanostat Voltalab Model 21. For the chemical test, the samples are rectangular with the dimensions 35X10X1.7 mm. The solution used and the operating conditions are described in the ISO 10271. The concentration of metallic ions released is measured by Induced Coupled Plasma Y1 - 2003 UR - https://www.researchgate.net/publication/242728857_A_proposal_for_the_classification_of_precious_dental_alloys_according_to_their_resistance_to_corrosion_based_on_the_ISO_10271_standard VL - 5 IS - SUPPL. 1 SP - 34 EP - 36 PB - Univ. of Wales CY - Aberystwyth, Wales ER - TY - JOUR A1 - Hornberger, Helga A1 - Weissmann, R. A1 - Lutz, N. T1 - Machining of silica glasses using excimer laser radiation JF - Glastechnische Berichte - Glass Science and Technology Y1 - 1996 VL - 69 IS - 2 SP - 44 EP - 49 ER - TY - JOUR A1 - Wessely, Rainer A1 - Hausleiter, Jörg A1 - Michaelis, Cornelia A1 - Jaschke, Birgit A1 - Vogeser, Michael A1 - Milz, Stefan A1 - Behnisch, Boris A1 - Schratzenstaller, Thomas A1 - Renke-Gluszko, Magdalena A1 - Stöver, Michael A1 - Wintermantel, Erich A1 - Kastrati, Adnan A1 - Schömig, Albert T1 - Inhibition of neointima formation by a novel drug-eluting stent system that allows for dose-adjustable, multiple, and on-site stent coating JF - Arteriosclerosis, Thrombosis, and Vascular Biology N2 - Objective The risk of in-stent restenosis can be considerably reduced by stents eluting cytostatic compounds. We created a novel drug-eluting stent system that includes several new features in the rapidly evolving field of stent-based drug delivery. Methods and Results The aim of the present study was the preclinical evaluation of a stent-coating system permitting individual, on-site coating of stents with a unique microporous surface allowing for individualizable, dose-adjustable, and multiple coatings with identical or various compounds, designated ISAR (individualizable drug-eluting stent system to abrogate restenosis). Stents were coated with 0.75% rapamycin solution, and high-performance liquid chromatography (HPLC)-based determination of drug release profile indicated drug release for >21 days. Rapamycin-eluting microporous (REMP) stents implanted in porcine coronary arteries were safe. To determine the efficacy of REMP stents, this novel drug-eluting stent platform was compared with the standard sirolimus-eluting stent. At 30 days, in-stent neointima formation in porcine coronary arteries was similar in both groups, yielding a significant decrease of neointimal area and injury-dependent neointimal thickness compared with bare-metal stents. Conclusion The ISAR drug-eluting stent platform as a novel concept for stent coating allows for a safe, effective, on-site stent coating process, thus justifying further clinical evaluation to decrease in-stent restenosis in humans. In-stent neointima formation can be successfully attenuated by drug-eluting stents. We introduce a novel conceptual approach for stent-coating that allows for dose-adjustable, on-site stent coating process if desired with multiple compounds. Microporous stents coated with rapamycin proved safe and effective for the limitation of neointima formation in a porcine coronary stent model. KW - drug-eluting stent KW - stent platform KW - sirolimus KW - rapamycin Y1 - 2005 U6 - https://doi.org/10.1161/01.ATV.0000157579.52566.ee SN - 1524-4636 VL - 25 IS - 4 SP - 748 EP - 753 ER - TY - JOUR A1 - Hausleiter, Jörg A1 - Kastrati, Adnan A1 - Wessely, Rainer A1 - Dibra, Alban A1 - Mehilli, Julinda A1 - Schratzenstaller, Thomas A1 - Graf, Isolde A1 - Renke-Gluszko, Magdalena A1 - Behnisch, Boris A1 - Dirschinger, Josef A1 - Wintermantel, Erich A1 - Schömig, Albert T1 - Prevention of restenosis by a novel drug-eluting stent system with a dose-adjustable, polymer-free, on-site stent coating JF - European Heart Journal - Clinical research N2 - Aims Drug-eluting stents (DES) represent a major advance in interventional cardiology. Along with the success shown, current DES also present limitations related to the presence of polymer-coating, fixed drug, and dose used. With the ISAR (Individualized Drug-Eluting Stent System to Abrogate Restenosis) project, a DES system has been developed that permits individualized choice of the drug and dose to use for the given patient. The objective of this prospective dose finding study was to assess the feasibility, safety, and efficacy of a polymer-free on-site stent coating with increasing rapamycin doses. Methods and results In this dose finding study, 602 patients were sequentially enrolled in four groups: microporous bare metal stent (BMS), DES stents coated with a 0.5, 1.0, and 2.0% rapamycin solution. The angiographic in-segment restenosis rate at follow-up angiography was the primary study endpoint. In-segment restenosis was significantly reduced from 25.9% with BMS to 18.9, 17.2, and 14.7% with 0.5, 1.0, and 2.0% rapamycin-eluting stents, respectively (P=0.024). Similarly, the need for target lesion revascularization at 1 year follow-up was reduced from 21.5% with BMS to 16.4, 12.6, and 8.8% with 0.5, 1.0, and 2.0% rapamycin-eluting stents, respectively (P=0.006). Conclusion The placement of polymer-free stents coated on-site with rapamycin is feasible and safe. Furthermore, a dose-dependent efficacy in restenosis prevention is achievable with this new DES concept. KW - Restenosis KW - Stents KW - Randomized KW - Rapamycin KW - Polymer Y1 - 2005 U6 - https://doi.org/10.1093/eurheartj/ehi405 VL - 26 IS - 15 SP - 1475 EP - 1481 ER - TY - CHAP A1 - Weber, Karsten T1 - Der Preis der Informationsfreiheit T2 - Wissen und Bildung in der modernen Gesellschaft Y1 - 2005 UR - https://www.hg-graebe.de/Texte/RLKonf-2005/weber-05-1.pdf PB - Rosa-Luxemburg-Stiftung e.V. CY - Leipzig ER - TY - CHAP A1 - Meyer-Sickendiek, Burkhard A1 - Hussein, Hussein A1 - Baumann, Timo ED - Berton, André ED - Haiber, Udo ED - Minker, Wolfgang T1 - Recognizing Modern Sound Poetry with LSTM Networks T2 - Proceedings of Elektronische Sprachsignalverarbeitung (ESSV) N2 - Our paper focuses on the computational analysis of “readout poetry” (german: Hördichtung) – recordings of poets reading their own work – with regards to the most important type of this genre, the modern “sound poetry” (german: Lautdichtung). Whereas “readout poetry” often uses normal words and sentences, the “sound poetry”, developed by dadaistic poets like Hugo Ball and Kurt Schwitters or concrete poets like Ernst Jandl, Oskar Pastior, or Bob Cobbing, combines the “microparticles of the human voice” like the segments in Ernst Jandls sound poem “schtzngrmm” (“schtzngrmm / schtzngrmm / tttt / tttt / grrrmmmmm / tttt / sch / tzngrmm”). Within the genre of sound poetry, there are two main forms: The lettristic and the syllabic decomposition. A short anecdote will explain this difference: The dadaist Raoul Hausmann developed the lettristic sound poetry in his early dadaistic poem “fmsbw” from 1918. This is said to have inspired his successor Schwitters, whose famous “Ursonate” [The Sonata in Primal Speech] begins with the words “Fümms bö wö tää zää Uu”. With the “Ursonate”, Schwitters developed a syllabic variation of the lettristic poems of Hausmann. The paper shows how to train a bidirectional LSTM network in order to differ between these “dadaistic” sound poems and the “normal” read out poems. In a further step, we will also show how to distinguish between the lettristic and the syllabic decomposition. Based on a bidirectional LSTM network that reads encodings of the character sequence in the poem and uses the output of each directional layer, we identify poems of the sound poetry genre and differentiate between its two types of compositions. The classification results of sound poetry vs. other poetry as well as lettristic vs. syllabic decomposition are with a high performance, yielding a f-scores of 0.86 and 0.84, respectively. KW - Sprachverarbeitung Y1 - 2018 UR - http://www.essv.de/paper.php?id=407 SN - 978-3-959081-28-3 SP - 192 EP - 199 PB - TUDpress CY - Ulm, Germany ER - TY - CHAP A1 - Laumer, Tobias A1 - Schmidt, Michael A1 - Stichel, Thomas T1 - Correlation Analysis of Different Building Parameters on the Part Properties of Parts Built by Simultaneous Laser Beam Melting of Polymers T2 - Fraunhofer Direct Digital Manufacturing Conference DDMC 2016 : Conference Proceedings, March 2016, Berlin N2 - Simultaneous Laser Beam Melting of polymers (SLBM) allows the generation of multi-material components,consisting of different thermoplastic polymers, within one additive building process. Besides the common advantagesof conventional Laser Beam Melting (LBM), multi-material components built by SLBM can fulfill different productrequirements like different chemical resistances or haptic material properties within a single part. To achieve suchparts, different powder materials are deposited next to each other and preheated a few degrees below their meltingtemperatures by infrared emitters and laser radiation (λ = 10.60 μm), before in the last step the preheated powdersare molten simultaneously by an additional laser source (λ = 1.94 μm). In this paper, different polymer powders likepolypropylene (PP) and polyamide 12 (PA12) are used for the generation of multi-material specimens. By varyingdifferent building parameters according to a specified design of experiments, their influence on the part properties isanalyzed. Important building parameters are the intensity and the irradiation time of the laser beam used for meltingthe preheated powders. Besides using tensile tests to determine the tensile strength and the elongation at break, theaverage part height in dependence of the energy input is analyzed. The overall aim is to specify the correlationbetween different building parameters regarding the energy deposition on the resulting part properties. Y1 - 2016 UR - https://www.researchgate.net/publication/298791419_Correlation_Analysis_of_Different_Building_Parameters_on_the_Part_Properties_of_Parts_Built_by_Simultaneous_Laser_Beam_Melting_of_Polymers PB - Fraunhofer Verlag ER - TY - CHAP A1 - Laumer, Tobias A1 - Stichel, Thomas A1 - Bock, Thomas A1 - Amend, Philipp A1 - Schmidt, Michael T1 - Characterization of temperature-dependent optical material properties of polymer powders T2 - AIP Conference Proceedings N2 - In former works, the optical material properties of different polymer powders used for Laser Beam Melting (LBM) at room temperature have been analyzed. With a measurement setup using two integration spheres, it was shown that the optical material properties of polymer powders differ significantly due to multiple reflections within the powder compared to solid bodies of the same material. Additionally, the absorption behavior of the single particles shows an important influence on the overall optical material properties, especially the reflectance of the powder bed. Now the setup is modified to allow measurements at higher temperatures. Because crystalline areas of semi-crystalline thermoplastics are mainly responsible for the absorption of the laser radiation, the influence of the temperature increase on the overall optical material properties is analyzed. As material, conventional polyamide 12 and polypropylene as new polymer powder material, is used. By comparing results at room temperature and at higher temperatures towards the melting point, the temperature-dependent optical material properties and their influence on the beam-matter interaction during the process are discussed. It is shown that the phase transition during melting leads to significant changes of the optical material properties of the analyzed powders. KW - laser beam melting KW - material qualification KW - Optical Material Properties KW - Polymers Y1 - 2014 U6 - https://doi.org/10.1063/1.4918508 IS - 1 PB - AIP Publishing ER - TY - JOUR A1 - Laumer, Tobias A1 - Stichel, Thomas A1 - Raths, Max A1 - Schmidt, Michael T1 - Analysis of the Influence of Different Flowability on Part Characteristics Regarding the Simultaneous Laser Beam Melting of Polymers JF - Physics Procedia N2 - Powder based Additive Manufacturing technologies offer huge potential for building parts with almost no geometrical restrictions, but both the process controlling as well as the part properties are strongly dependent on different material characteristics of the material, like the flowability. In this work, different weight percentages of nano-scaled silica dioxide particles (Aerosil®) are admixed to pure polyethylene and polypropylene powder and the resulting flowability is determined. Besides using the Hausner ratio as standardized value, the degree of coverage is introduced as a new characteristic to quantify the powder flowability. The degrees of coverage are compared to the Hausner ratios to allow a discussion and evaluation about the different characteristic values. Additionally, tensile bars consisting of polypropylene are generated to determine the porosity by cross sections and the mechanical part properties by tensile testing. As mechanical part properties, the tensile strength and elongation at break are determined and the effects of different powder flowability on these properties are analyzed. KW - additive manufacturing KW - laser beam melting of polymers KW - material qualification Y1 - 2016 U6 - https://doi.org/10.1016/j.phpro.2016.08.098 SN - 1875-3892 SN - 1875-3884 VL - 83 SP - 937 EP - 946 PB - Elsevier ER -