TY - JOUR A1 - Hartmann, Robin A1 - Nieberle, Felix A1 - Palm, Christoph A1 - Brébant, Vanessa A1 - Prantl, Lukas A1 - Kuehle, Reinald A1 - Reichert, Torsten E. A1 - Taxis, Juergen A1 - Ettl, Tobias T1 - Utility of Smartphone-based Three-dimensional Surface Imaging for Digital Facial Anthropometry JF - JPRAS Open N2 - Background The utilization of three-dimensional (3D) surface imaging for facial anthropometry is a significant asset for patients undergoing maxillofacial surgery. Notably, there have been recent advancements in smartphone technology that enable 3D surface imaging. In this study, anthropometric assessments of the face were performed using a smartphone and a sophisticated 3D surface imaging system. Methods 30 healthy volunteers (15 females and 15 males) were included in the study. An iPhone 14 Pro (Apple Inc., USA) using the application 3D Scanner App (Laan Consulting Corp., USA) and the Vectra M5 (Canfield Scientific, USA) were employed to create 3D surface models. For each participant, 19 anthropometric measurements were conducted on the 3D surface models. Subsequently, the anthropometric measurements generated by the two approaches were compared. The statistical techniques employed included the paired t-test, paired Wilcoxon signed-rank test, Bland–Altman analysis, and calculation of the intraclass correlation coefficient (ICC). Results All measurements showed excellent agreement between smartphone-based and Vectra M5-based measurements (ICC between 0.85 and 0.97). Statistical analysis revealed no statistically significant differences in the central tendencies for 17 of the 19 linear measurements. Despite the excellent agreement found, Bland–Altman analysis revealed that the 95% limits of agreement between the two methods exceeded ±3 mm for the majority of measurements. Conclusion Digital facial anthropometry using smartphones can serve as a valuable supplementary tool for surgeons, enhancing their communication with patients. However, the proposed data suggest that digital facial anthropometry using smartphones may not yet be suitable for certain diagnostic purposes that require high accuracy. KW - Three-dimensional surface imaging KW - Stereophotogrammetry KW - Smartphone-based surface imaging KW - Digital anthropometry KW - Facial anthropometry Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-70348 VL - 39 SP - 330 EP - 343 PB - Elsevier ER - TY - JOUR A1 - Ebigbo, Alanna A1 - Mendel, Robert A1 - Scheppach, Markus W. A1 - Probst, Andreas A1 - Shahidi, Neal A1 - Prinz, Friederike A1 - Fleischmann, Carola A1 - Römmele, Christoph A1 - Gölder, Stefan Karl A1 - Braun, Georg A1 - Rauber, David A1 - Rückert, Tobias A1 - Souza Jr., Luis Antonio de A1 - Papa, João Paulo A1 - Byrne, Michael F. A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Vessel and tissue recognition during third-space endoscopy using a deep learning algorithm JF - Gut N2 - In this study, we aimed to develop an artificial intelligence clinical decision support solution to mitigate operator-dependent limitations during complex endoscopic procedures such as endoscopic submucosal dissection and peroral endoscopic myotomy, for example, bleeding and perforation. A DeepLabv3-based model was trained to delineate vessels, tissue structures and instruments on endoscopic still images from such procedures. The mean cross-validated Intersection over Union and Dice Score were 63% and 76%, respectively. Applied to standardised video clips from third-space endoscopic procedures, the algorithm showed a mean vessel detection rate of 85% with a false-positive rate of 0.75/min. These performance statistics suggest a potential clinical benefit for procedure safety, time and also training. KW - Artificial Intelligence KW - Endoscopy KW - Medical Image Computing Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-54293 VL - 71 IS - 12 SP - 2388 EP - 2390 PB - BMJ CY - London ER - TY - JOUR A1 - Knödler, Leonard A1 - Baecher, Helena A1 - Kauke-Navarro, Martin A1 - Prantl, Lukas A1 - Machens, Hans-Günther A1 - Scheuermann, Philipp A1 - Palm, Christoph A1 - Baumann, Raphael A1 - Kehrer, Andreas A1 - Panayi, Adriana C. A1 - Knoedler, Samuel T1 - Towards a Reliable and Rapid Automated Grading System in Facial Palsy Patients: Facial Palsy Surgery Meets Computer Science JF - Journal of Clinical Medicine N2 - Background: Reliable, time- and cost-effective, and clinician-friendly diagnostic tools are cornerstones in facial palsy (FP) patient management. Different automated FP grading systems have been developed but revealed persisting downsides such as insufficient accuracy and cost-intensive hardware. We aimed to overcome these barriers and programmed an automated grading system for FP patients utilizing the House and Brackmann scale (HBS). Methods: Image datasets of 86 patients seen at the Department of Plastic, Hand, and Reconstructive Surgery at the University Hospital Regensburg, Germany, between June 2017 and May 2021, were used to train the neural network and evaluate its accuracy. Nine facial poses per patient were analyzed by the algorithm. Results: The algorithm showed an accuracy of 100%. Oversampling did not result in altered outcomes, while the direct form displayed superior accuracy levels when compared to the modular classification form (n = 86; 100% vs. 99%). The Early Fusion technique was linked to improved accuracy outcomes in comparison to the Late Fusion and sequential method (n = 86; 100% vs. 96% vs. 97%). Conclusions: Our automated FP grading system combines high-level accuracy with cost- and time-effectiveness. Our algorithm may accelerate the grading process in FP patients and facilitate the FP surgeon’s workflow. Y1 - 2022 U6 - https://doi.org/10.3390/jcm11174998 VL - 11 IS - 17 PB - MDPI CY - Basel ER - TY - JOUR A1 - Souza Jr., Luis Antonio de A1 - Palm, Christoph A1 - Mendel, Robert A1 - Hook, Christian A1 - Ebigbo, Alanna A1 - Probst, Andreas A1 - Messmann, Helmut A1 - Weber, Silke A. T. A1 - Papa, João Paulo T1 - A survey on Barrett's esophagus analysis using machine learning JF - Computers in Biology and Medicine N2 - This work presents a systematic review concerning recent studies and technologies of machine learning for Barrett's esophagus (BE) diagnosis and treatment. The use of artificial intelligence is a brand new and promising way to evaluate such disease. We compile some works published at some well-established databases, such as Science Direct, IEEEXplore, PubMed, Plos One, Multidisciplinary Digital Publishing Institute (MDPI), Association for Computing Machinery (ACM), Springer, and Hindawi Publishing Corporation. Each selected work has been analyzed to present its objective, methodology, and results. The BE progression to dysplasia or adenocarcinoma shows a complex pattern to be detected during endoscopic surveillance. Therefore, it is valuable to assist its diagnosis and automatic identification using computer analysis. The evaluation of the BE dysplasia can be performed through manual or automated segmentation through machine learning techniques. Finally, in this survey, we reviewed recent studies focused on the automatic detection of the neoplastic region for classification purposes using machine learning methods. KW - Speiseröhrenkrankheit KW - Diagnose KW - Mustererkennung KW - Maschinelles Lernen KW - Literaturbericht KW - Barrett's esophagus KW - Machine learning KW - Adenocarcinoma KW - Image processing KW - Pattern recognition KW - Computer-aided diagnosis Y1 - 2018 U6 - https://doi.org/10.1016/j.compbiomed.2018.03.014 VL - 96 SP - 203 EP - 213 PB - Elsevier ER - TY - JOUR A1 - Ott, Tankred A1 - Palm, Christoph A1 - Vogt, Robert A1 - Oberprieler, Christoph T1 - GinJinn: An object-detection pipeline for automated feature extraction from herbarium specimens JF - Applications in Plant Sciences N2 - PREMISE: The generation of morphological data in evolutionary, taxonomic, and ecological studies of plants using herbarium material has traditionally been a labor-intensive task. Recent progress in machine learning using deep artificial neural networks (deep learning) for image classification and object detection has facilitated the establishment of a pipeline for the automatic recognition and extraction of relevant structures in images of herbarium specimens. METHODS AND RESULTS: We implemented an extendable pipeline based on state-of-the-art deep-learning object-detection methods to collect leaf images from herbarium specimens of two species of the genus Leucanthemum. Using 183 specimens as the training data set, our pipeline extracted one or more intact leaves in 95% of the 61 test images. CONCLUSIONS: We establish GinJinn as a deep-learning object-detection tool for the automatic recognition and extraction of individual leaves or other structures from herbarium specimens. Our pipeline offers greater flexibility and a lower entrance barrier than previous image-processing approaches based on hand-crafted features. KW - Deep Learning KW - herbarium specimens KW - object detection KW - visual recognition KW - Deep Learning KW - Objekterkennung KW - Maschinelles Sehen KW - Pflanzen Y1 - 2020 U6 - https://doi.org/10.1002/aps3.11351 SN - 2168-0450 VL - 8 IS - 6 SP - e11351 PB - Wiley, Botanical Society of America ER - TY - JOUR A1 - Ebigbo, Alanna A1 - Palm, Christoph A1 - Probst, Andreas A1 - Mendel, Robert A1 - Manzeneder, Johannes A1 - Prinz, Friederike A1 - Souza Jr., Luis Antonio de A1 - Papa, João Paulo A1 - Siersema, Peter A1 - Messmann, Helmut T1 - A technical review of artificial intelligence as applied to gastrointestinal endoscopy: clarifying the terminology JF - Endoscopy International Open N2 - The growing number of publications on the application of artificial intelligence (AI) in medicine underlines the enormous importance and potential of this emerging field of research. In gastrointestinal endoscopy, AI has been applied to all segments of the gastrointestinal tract most importantly in the detection and characterization of colorectal polyps. However, AI research has been published also in the stomach and esophagus for both neoplastic and non-neoplastic disorders. The various technical as well as medical aspects of AI, however, remain confusing especially for non-expert physicians. This physician-engineer co-authored review explains the basic technical aspects of AI and provides a comprehensive overview of recent publications on AI in gastrointestinal endoscopy. Finally, a basic insight is offered into understanding publications on AI in gastrointestinal endoscopy. KW - Diagnose KW - Maschinelles Lernen KW - Gastroenterologie KW - Künstliche Intelligenz KW - Barrett's esophagus KW - Deep learning Y1 - 2019 U6 - https://doi.org/10.1055/a-1010-5705 VL - 07 IS - 12 SP - 1616 EP - 1623 PB - Georg Thieme Verlag CY - Stuttgart ER - TY - CHAP A1 - Wöhl, Rebecca A1 - Huber, Michaela A1 - Loibl, Markus A1 - Riebschläger, Birgit A1 - Nerlich, Michael A1 - Palm, Christoph T1 - The Impact of Semi-Automated Segmentation and 3D Analysis on Testing New Osteosynthesis Material T2 - Bildverarbeitung für die Medizin 2017; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 12. bis 14. März 2017 in Heidelberg N2 - A new protocol for testing osteosynthesis material postoperatively combining semi-automated segmentation and 3D analysis of surface meshes is proposed. By various steps of transformation and measuring, objective data can be collected. In this study the specifications of a locking plate used for mediocarpal arthrodesis of the wrist were examined. The results show, that union of the lunate, triquetrum, hamate and capitate was achieved and that the plate is comparable to coexisting arthrodesis systems. Additionally, it was shown, that the complications detected correlate to the clinical outcome. In synopsis, this protocol is considered beneficial and should be taken into account in further studies. KW - Osteosynthese KW - Implantatwerkstoff KW - Materialprüfung KW - Bildsegmentierung KW - Dreidimensionale Bildverarbeitung Y1 - 2017 U6 - https://doi.org/10.1007/978-3-662-54345-0_30 SP - 122 EP - 127 PB - Springer CY - Berlin ER - TY - JOUR A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Palm, Christoph A1 - Probst, Andreas A1 - Muzalyova, Anna A1 - Scheppach, Markus W. A1 - Nagl, Sandra A1 - Schnoy, Elisabeth A1 - Römmele, Christoph A1 - Schulz, Dominik Andreas Helmut Otto A1 - Schlottmann, Jakob A1 - Prinz, Friederike A1 - Rauber, David A1 - Rückert, Tobias A1 - Matsumura, Tomoaki A1 - Fernández-Esparrach, Glòria A1 - Parsa, Nasim A1 - Byrne, Michael F. A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Influence of artificial intelligence on the diagnostic performance of endoscopists in the assessment of Barrett’s esophagus: a tandem randomized and video trial JF - Endoscopy N2 - Background This study evaluated the effect of an artificial intelligence (AI)-based clinical decision support system on the performance and diagnostic confidence of endoscopists in their assessment of Barrett’s esophagus (BE). Methods 96 standardized endoscopy videos were assessed by 22 endoscopists with varying degrees of BE experience from 12 centers. Assessment was randomized into two video sets: group A (review first without AI and second with AI) and group B (review first with AI and second without AI). Endoscopists were required to evaluate each video for the presence of Barrett’s esophagus-related neoplasia (BERN) and then decide on a spot for a targeted biopsy. After the second assessment, they were allowed to change their clinical decision and confidence level. Results AI had a stand-alone sensitivity, specificity, and accuracy of 92.2%, 68.9%, and 81.3%, respectively. Without AI, BE experts had an overall sensitivity, specificity, and accuracy of 83.3%, 58.1%, and 71.5%, respectively. With AI, BE nonexperts showed a significant improvement in sensitivity and specificity when videos were assessed a second time with AI (sensitivity 69.8% [95%CI 65.2%–74.2%] to 78.0% [95%CI 74.0%–82.0%]; specificity 67.3% [95%CI 62.5%–72.2%] to 72.7% [95%CI 68.2%–77.3%]). In addition, the diagnostic confidence of BE nonexperts improved significantly with AI. Conclusion BE nonexperts benefitted significantly from additional AI. BE experts and nonexperts remained significantly below the stand-alone performance of AI, suggesting that there may be other factors influencing endoscopists’ decisions to follow or discard AI advice. KW - Artificial Intelligence KW - Endoscopy KW - Medical Image Computing Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-72818 VL - 56 SP - 641 EP - 649 PB - Georg Thieme Verlag CY - Stuttgart ER - TY - GEN A1 - Ebigbo, Alanna A1 - Rauber, David A1 - Ayoub, Mousa A1 - Birzle, Lisa A1 - Matsumura, Tomoaki A1 - Probst, Andreas A1 - Steinbrück, Ingo A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Meinikheim, Michael A1 - Scheppach, Markus W. A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Early Esophageal Cancer and the Generalizability of Artificial Intelligence T2 - Endoscopy N2 - Aims Artificial Intelligence (AI) systems in gastrointestinal endoscopy are narrow because they are trained to solve only one specific task. Unlike Narrow-AI, general AI systems may be able to solve multiple and unrelated tasks. We aimed to understand whether an AI system trained to detect, characterize, and segment early Barrett’s neoplasia (Barrett’s AI) is only capable of detecting this pathology or can also detect and segment other diseases like early squamous cell cancer (SCC). Methods 120 white light (WL) and narrow-band endoscopic images (NBI) from 60 patients (1 WL and 1 NBI image per patient) were extracted from the endoscopic database of the University Hospital Augsburg. Images were annotated by three expert endoscopists with extensive experience in the diagnosis and endoscopic resection of early esophageal neoplasias. An AI system based on DeepLabV3+architecture dedicated to early Barrett’s neoplasia was tested on these images. The AI system was neither trained with SCC images nor had it seen the test images prior to evaluation. The overlap between the three expert annotations („expert-agreement“) was the ground truth for evaluating AI performance. Results Barrett’s AI detected early SCC with a mean intersection over reference (IoR) of 92% when at least 1 pixel of the AI prediction overlapped with the expert-agreement. When the threshold was increased to 5%, 10%, and 20% overlap with the expert-agreement, the IoR was 88%, 85% and 82%, respectively. The mean Intersection Over Union (IoU) – a metric according to segmentation quality between the AI prediction and the expert-agreement – was 0.45. The mean expert IoU as a measure of agreement between the three experts was 0.60. Conclusions In the context of this pilot study, the predictions of SCC by a Barrett’s dedicated AI showed some overlap to the expert-agreement. Therefore, features learned from Barrett’s cancer-related training might be helpful also for SCC prediction. Our results allow different possible explanations. On the one hand, some Barrett’s cancer features generalize toward the related task of assessing early SCC. On the other hand, the Barrett’s AI is less specific to Barrett’s cancer than a general predictor of pathological tissue. However, we expect to enhance the detection quality significantly by extending the training to SCC-specific data. The insight of this study opens the way towards a transfer learning approach for more efficient training of AI to solve tasks in other domains. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1783775 VL - 56 IS - S 02 SP - S428 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Rauber, David A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Meinikheim, Michael A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Artificial Intelligence (AI) improves endoscopists’ vessel detection during endoscopic submucosal dissection (ESD) T2 - Endoscopy N2 - Aims While AI has been successfully implemented in detecting and characterizing colonic polyps, its role in therapeutic endoscopy remains to be elucidated. Especially third space endoscopy procedures like ESD and peroral endoscopic myotomy (POEM) pose a technical challenge and the risk of operator-dependent complications like intraprocedural bleeding and perforation. Therefore, we aimed at developing an AI-algorithm for intraprocedural real time vessel detection during ESD and POEM. Methods A training dataset consisting of 5470 annotated still images from 59 full-length videos (47 ESD, 12 POEM) and 179681 unlabeled images was used to train a DeepLabV3+neural network with the ECMT semi-supervised learning method. Evaluation for vessel detection rate (VDR) and time (VDT) of 19 endoscopists with and without AI-support was performed using a testing dataset of 101 standardized video clips with 200 predefined blood vessels. Endoscopists were stratified into trainees and experts in third space endoscopy. Results The AI algorithm had a mean VDR of 93.5% and a median VDT of 0.32 seconds. AI support was associated with a statistically significant increase in VDR from 54.9% to 73.0% and from 59.0% to 74.1% for trainees and experts, respectively. VDT significantly decreased from 7.21 sec to 5.09 sec for trainees and from 6.10 sec to 5.38 sec for experts in the AI-support group. False positive (FP) readings occurred in 4.5% of frames. FP structures were detected significantly shorter than true positives (0.71 sec vs. 5.99 sec). Conclusions AI improved VDR and VDT of trainees and experts in third space endoscopy and may reduce performance variability during training. Further research is needed to evaluate the clinical impact of this new technology. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1782891 VL - 56 IS - S 02 SP - S93 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Zellmer, Stephan A1 - Rauber, David A1 - Probst, Andreas A1 - Weber, Tobias A1 - Braun, Georg A1 - Römmele, Christoph A1 - Nagl, Sandra A1 - Schnoy, Elisabeth A1 - Messmann, Helmut A1 - Ebigbo, Alanna A1 - Palm, Christoph T1 - Artificial intelligence as a tool in the detection of the papillary ostium during ERCP T2 - Endoscopy N2 - Aims Endoscopic retrograde cholangiopancreaticography (ERCP) is the gold standard in the diagnosis as well as treatment of diseases of the pancreatobiliary tract. However, it is technically complex and has a relatively high complication rate. In particular, cannulation of the papillary ostium remains challenging. The aim of this study is to examine whether a deep-learning algorithm can be used to detect the major duodenal papilla and in particular the papillary ostium reliably and could therefore be a valuable tool for inexperienced endoscopists, particularly in training situation. Methods We analyzed a total of 654 retrospectively collected images of 85 patients. Both the major duodenal papilla and the ostium were then segmented. Afterwards, a neural network was trained using a deep-learning algorithm. A 5-fold cross-validation was performed. Subsequently, we ran the algorithm on 5 prospectively collected videos of ERCPs. Results 5-fold cross-validation on the 654 labeled data resulted in an F1 value of 0.8007, a sensitivity of 0.8409 and a specificity of 0.9757 for the class papilla, and an F1 value of 0.5724, a sensitivity of 0.5456 and a specificity of 0.9966 for the class ostium. Regardless of the class, the average F1 value (class papilla and class ostium) was 0.6866, the sensitivity 0.6933 and the specificity 0.9861. In 100% of cases the AI-detected localization of the papillary ostium in the prospectively collected videos corresponded to the localization of the cannulation performed by the endoscopist. Conclusions In the present study, the neural network was able to identify the major duodenal papilla with a high sensitivity and high specificity. In detecting the papillary ostium, the sensitivity was notably lower. However, when used on videos, the AI was able to identify the location of the subsequent cannulation with 100% accuracy. In the future, the neural network will be trained with more data. Thus, a suitable tool for ERCP could be established, especially in the training situation. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1783138 VL - 56 IS - S 02 SP - S198 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Scheppach, Markus W. A1 - Nunes, Danilo Weber A1 - Arizi, X. A1 - Rauber, David A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Meinikheim, Michael A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Procedural phase recognition in endoscopic submucosal dissection (ESD) using artificial intelligence (AI) T2 - Endoscopy N2 - Aims Recent evidence suggests the possibility of intraprocedural phase recognition in surgical operations as well as endoscopic interventions such as peroral endoscopic myotomy and endoscopic submucosal dissection (ESD) by AI-algorithms. The intricate measurement of intraprocedural phase distribution may deepen the understanding of the procedure. Furthermore, real-time quality assessment as well as automation of reporting may become possible. Therefore, we aimed to develop an AI-algorithm for intraprocedural phase recognition during ESD. Methods A training dataset of 364385 single images from 9 full-length ESD videos was compiled. Each frame was classified into one procedural phase. Phases included scope manipulation, marking, injection, application of electrical current and bleeding. Allocation of each frame was only possible to one category. This training dataset was used to train a Video Swin transformer to recognize the phases. Temporal information was included via logarithmic frame sampling. Validation was performed using two separate ESD videos with 29801 single frames. Results The validation yielded sensitivities of 97.81%, 97.83%, 95.53%, 85.01% and 87.55% for scope manipulation, marking, injection, electric application and bleeding, respectively. Specificities of 77.78%, 90.91%, 95.91%, 93.65% and 84.76% were measured for the same parameters. Conclusions The developed algorithm was able to classify full-length ESD videos on a frame-by-frame basis into the predefined classes with high sensitivities and specificities. Future research will aim at the development of quality metrics based on single-operator phase distribution. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1783804 VL - 56 IS - S 02 SP - S439 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Scheppach, Markus W. A1 - Rauber, David A1 - Stallhofer, Johannes A1 - Muzalyova, Anna A1 - Otten, Vera A1 - Manzeneder, Carolin A1 - Schwamberger, Tanja A1 - Wanzl, Julia A1 - Schlottmann, Jakob A1 - Tadic, Vidan A1 - Probst, Andreas A1 - Schnoy, Elisabeth A1 - Römmele, Christoph A1 - Fleischmann, Carola A1 - Meinikheim, Michael A1 - Miller, Silvia A1 - Märkl, Bruno A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Performance comparison of a deep learning algorithm with endoscopists in the detection of duodenal villous atrophy (VA) T2 - Endoscopy N2 - Aims  VA is an endoscopic finding of celiac disease (CD), which can easily be missed if pretest probability is low. In this study, we aimed to develop an artificial intelligence (AI) algorithm for the detection of villous atrophy on endoscopic images. Methods 858 images from 182 patients with VA and 846 images from 323 patients with normal duodenal mucosa were used for training and internal validation of an AI algorithm (ResNet18). A separate dataset was used for external validation, as well as determination of detection performance of experts, trainees and trainees with AI support. According to the AI consultation distribution, images were stratified into “easy” and “difficult”. Results Internal validation showed 82%, 85% and 84% for sensitivity, specificity and accuracy. External validation showed 90%, 76% and 84%. The algorithm was significantly more sensitive and accurate than trainees, trainees with AI support and experts in endoscopy. AI support in trainees was associated with significantly improved performance. While all endoscopists showed significantly lower detection for “difficult” images, AI performance remained stable. Conclusions The algorithm outperformed trainees and experts in sensitivity and accuracy for VA detection. The significant improvement with AI support suggests a potential clinical benefit. Stable performance of the algorithm in “easy” and “difficult” test images may indicate an advantage in macroscopically challenging cases. Y1 - 2023 U6 - https://doi.org/10.1055/s-0043-1765421 VL - 55 IS - S02 PB - Thieme ER - TY - GEN A1 - Scheppach, Markus W. A1 - Weber Nunes, Danilo A1 - Arizi, X. A1 - Rauber, David A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Single frame workflow recognition during endoscopic submucosal dissection (ESD) using artificial intelligence (AI) T2 - Endoscopy N2 - Aims  Precise surgical phase recognition and evaluation may improve our understanding of complex endoscopic procedures. Furthermore, quality control measurements and endoscopy training could benefit from objective descriptions of surgical phase distributions. Therefore, we aimed to develop an artificial intelligence algorithm for frame-by-frame operational phase recognition during endoscopic submucosal dissection (ESD). Methods  Full length ESD-videos from 31 patients comprising 6.297.782 single images were collected retrospectively. Videos were annotated on a frame-by-frame basis for the operational macro-phases diagnostics, marking, injection, dissection and bleeding. Further subphases were the application of electrical current, visible injection of fluid into the submucosal space and scope manipulation, leading to 11 phases in total. 4.975.699 frames (21 patients) were used for training of a video swin transformer using uniform frame sampling for temporal information. Hyperparameter tuning was performed with 897.325 further frames (6 patients), while 424.758 frames (4 patients) were used for validation. Results  The overall F1 scores on the test dataset for the macro-phases and all 11 phases were 0.96 and 0.90, respectively. The recall values for diagnostics, marking, injection, dissection and bleeding were 1.00, 1.00, 0.95, 0.96 and 0.93, respectively. Conclusions  The algorithm classified operational phases during ESD with high accuracy. A precise evaluation of phase distribution may allow for the development of objective quality metrics for quality control and training. Y1 - 2025 U6 - https://doi.org/10.1055/s-0045-1806324 VL - 57 IS - S 02 SP - S511 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Roser, David A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Palm, Christoph A1 - Probst, Andreas A1 - Muzalyova, Anna A1 - Scheppach, Markus W. A1 - Nagl, Sandra A1 - Schnoy, Elisabeth A1 - Römmele, Christoph A1 - Schulz, Dominik Andreas Helmut Otto A1 - Schlottmann, Jakob A1 - Prinz, Friederike A1 - Rauber, David A1 - Rückert, Tobias A1 - Matsumura, Tomoaki A1 - Fernandez-Esparrach, G. A1 - Parsa, Nasim A1 - Byrne, Michael F. A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Human-Computer Interaction: Impact of Artificial Intelligence on the diagnostic confidence of endoscopists assessing videos of Barrett’s esophagus T2 - Endoscopy N2 - Aims Human-computer interactions (HCI) may have a relevant impact on the performance of Artificial Intelligence (AI). Studies show that although endoscopists assessing Barrett’s esophagus (BE) with AI improve their performance significantly, they do not achieve the level of the stand-alone performance of AI. One aspect of HCI is the impact of AI on the degree of certainty and confidence displayed by the endoscopist. Indirectly, diagnostic confidence when using AI may be linked to trust and acceptance of AI. In a BE video study, we aimed to understand the impact of AI on the diagnostic confidence of endoscopists and the possible correlation with diagnostic performance. Methods 22 endoscopists from 12 centers with varying levels of BE experience reviewed ninety-six standardized endoscopy videos. Endoscopists were categorized into experts and non-experts and randomly assigned to assess the videos with and without AI. Participants were randomized in two arms: Arm A assessed videos first without AI and then with AI, while Arm B assessed videos in the opposite order. Evaluators were tasked with identifying BE-related neoplasia and rating their confidence with and without AI on a scale from 0 to 9. Results The utilization of AI in Arm A (without AI first, with AI second) significantly elevated confidence levels for experts and non-experts (7.1 to 8.0 and 6.1 to 6.6, respectively). Only non-experts benefitted from AI with a significant increase in accuracy (68.6% to 75.5%). Interestingly, while the confidence levels of experts without AI were higher than those of non-experts with AI, there was no significant difference in accuracy between these two groups (71.3% vs. 75.5%). In Arm B (with AI first, without AI second), experts and non-experts experienced a significant reduction in confidence (7.6 to 7.1 and 6.4 to 6.2, respectively), while maintaining consistent accuracy levels (71.8% to 71.8% and 67.5% to 67.1%, respectively). Conclusions AI significantly enhanced confidence levels for both expert and non-expert endoscopists. Endoscopists felt significantly more uncertain in their assessments without AI. Furthermore, experts with or without AI consistently displayed higher confidence levels than non-experts with AI, irrespective of comparable outcomes. These findings underscore the possible role of AI in improving diagnostic confidence during endoscopic assessment. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1782859 SN - 1438-8812 VL - 56 IS - S 02 SP - 79 PB - Georg Thieme Verlag ER - TY - GEN A1 - Zellmer, Stephan A1 - Rauber, David A1 - Probst, Andreas A1 - Weber, Tobias A1 - Braun, Georg A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Schnoy, Elisabeth A1 - Birzle, Lisa A1 - Aehling, Niklas A1 - Schulz, Dominik Andreas Helmut Otto A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Künstliche Intelligenz als Hilfsmittel zur Detektion der Papilla duodeni major und des papillären Ostiums während der ERCP T2 - Zeitschrift für Gastroenterologie N2 - Einleitung  Die Endoskopische Retrograde Cholangiopankreatikographie (ERCP) ist der Goldstandard in der endoskopischen Therapie von Erkrankungen des pankreatobiliären Trakts. Allerdings ist sie technisch anspruchsvoll, schwer zu erlernen und mit einer relativ hohen Komplikationsrate assoziiert. Daher soll in der vorliegenden Machbarkeitsstudie geprüft werden, ob mithilfe eines Deeplearning- Algorithmus die Papille und das Ostium zuverlässig detektiert werden können und dieser für Endoskopiker, insbesondere in der Ausbildungssituation, ein geeignetes Hilfsmittel darstellen könnte. Material und Methodik Insgesamt wurden 1534 ERCP-Bilder von 134 Patienten analysiert, wobei sowohl die Papilla duodeni major als auch das Ostium segmentiert wurden. Anschließend erfolgte das Training eines neuronalen Netzes unter Verwendung eines Deep-Learning-Algorithmus. Für den Test des Algorithmus erfolgte eine fünffache Kreuzvalidierung. Ergebnisse  Auf den 1534 gelabelten Bildern wurden für die Klasse Papille ein F1-Wert von 0,7996, eine Sensitivität von 0,8488 und eine Spezifität von 0,9822 erzielt. Für die Klasse Ostium ergaben sich ein F1-Wert von 0,5198, eine Sensitivität von 0,5945 und eine Spezifität von 0,9974. Klassenübergreifend (Klasse Papille und Klasse Ostium) betrug der F1-Wert 0,6593, die Sensitivität 0,7216 und für die Spezifität 0,9898. Zusammenfassung  In der vorliegenden Machbarkeitsstudie zeigte das neuronale Netz eine hohe Sensitivität und eine sehr hohe Spezifität bei der Identifikation der Papilla duodeni major. Die Detektion des Ostiums erfolgte hingegen mit einer deutlich geringeren Sensitivität. Zukünftig ist eine Erweiterung des Trainingsdatensatzes um Videos und klinische Daten vorgesehen, um die Leistungsfähigkeit des Netzwerks zu verbessern. Hierdurch könnte langfristig ein geeignetes Assistenzsystem für die ERCP, insbesondere in der Ausbildungssituation etabliert werden. Y1 - 2025 U6 - https://doi.org/10.1055/s-0045-1806882 VL - 63 IS - 5 SP - e295 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Deserno, Thomas M. A1 - Handels, Heinz A1 - Maier-Hein, Klaus H. A1 - Mersmann, Sven A1 - Palm, Christoph A1 - Tolxdorff, Thomas A1 - Wagenknecht, Gudrun A1 - Wittenberg, Thomas T1 - Viewpoints on Medical Image Processing BT - From Science to Application JF - Current Medical Imaging Reviews N2 - Medical image processing provides core innovation for medical imaging. This paper is focused on recent developments from science to applications analyzing the past fifteen years of history of the proceedings of the German annual meeting on medical image processing (BVM). Furthermore, some members of the program committee present their personal points of views: (i) multi-modality for imaging and diagnosis, (ii) analysis of diffusion-weighted imaging, (iii) model-based image analysis, (iv) registration of section images, (v) from images to information in digital endoscopy, and (vi) virtual reality and robotics. Medical imaging and medical image computing is seen as field of rapid development with clear trends to integrated applications in diagnostics, treatment planning and treatment. KW - Medical imaging KW - Image processing KW - Image analysis KW - Vizualization KW - Multi-modal imaging KW - Diffusion-weighted imaging KW - Model-based imaging KW - Digital endoscopy KW - Bildgebendes Verfahren KW - Bildverarbeitung KW - Medizin Y1 - 2013 U6 - https://doi.org/10.2174/1573405611309020002 VL - 9 IS - 2 SP - 79 EP - 88 ER - TY - JOUR A1 - Becker, Johanna Sabine A1 - Matusch, Andreas A1 - Becker, Julia Susanne A1 - Wu, Bei A1 - Palm, Christoph A1 - Becker, Albert Johann A1 - Salber, Dagmar T1 - Mass spectrometric imaging (MSI) of metals using advanced BrainMet techniques for biomedical research JF - International Journal of Mass Spectrometry N2 - Mass spectrometric imaging (MSI) is a young innovative analytical technique and combines different fields of advanced mass spectrometry and biomedical research with the aim to provide maps of elements and molecules, complexes or fragments. Especially essential metals such as zinc, copper, iron and manganese play a functional role in signaling, metabolism and homeostasis of the cell. Due to the high degree of spatial organization of metals in biological systems their distribution analysis is of key interest in life sciences. We have developed analytical techniques termed BrainMet using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) imaging to measure the distribution of trace metals in biological tissues for biomedical research and feasibility studies—including bioaccumulation and bioavailability studies, ecological risk assessment and toxicity studies in humans and other organisms. The analytical BrainMet techniques provide quantitative images of metal distributions in brain tissue slices which can be combined with other imaging modalities such as photomicrography of native or processed tissue (histochemistry, immunostaining) and autoradiography or with in vivo techniques such as positron emission tomography or magnetic resonance tomography. Prospective and instrumental developments will be discussed concerning the development of the metalloprotein microscopy using a laser microdissection (LMD) apparatus for specific sample introduction into an inductively coupled plasma mass spectrometer (LMD-ICP-MS) or an application of the near field effect in LA-ICP-MS (NF-LA-ICP-MS). These nano-scale mass spectrometric techniques provide improved spatial resolution down to the single cell level. KW - Bioimaging KW - Brain tissue KW - Laser ablation inductively coupled plasma mass spectrometry KW - Laser microdissection inductively coupled plasma mass spectrometry KW - Metals KW - Metallomics KW - Nano-LA-ICP-MS KW - Tumour KW - Massenspektrometrie KW - Bildgebendes Verfahren KW - Metalle KW - Metallproteide KW - Gehirn Y1 - 2011 U6 - https://doi.org/10.1016/j.ijms.2011.01.015 VL - 307 IS - 1-3 SP - 3 EP - 15 PB - eLSEVIER CY - Elsevier ER - TY - JOUR A1 - Becker, Johanna Sabine A1 - Matusch, Andreas A1 - Palm, Christoph A1 - Salber, Dagmar A1 - Morton, Kathryn A. A1 - Becker, Julia Susanne T1 - Bioimaging of metals in brain tissue by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and metallomics JF - Metallomics N2 - Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been developed and established as an emerging technique in the generation of quantitative images of metal distributions in thin tissue sections of brain samples (such as human, rat and mouse brain), with applications in research related to neurodegenerative disorders. A new analytical protocol is described which includes sample preparation by cryo-cutting of thin tissue sections and matrix-matched laboratory standards, mass spectrometric measurements, data acquisition, and quantitative analysis. Specific examples of the bioimaging of metal distributions in normal rodent brains are provided. Differences to the normal were assessed in a Parkinson’s disease and a stroke brain model. Furthermore, changes during normal aging were studied. Powerful analytical techniques are also required for the determination and characterization of metal-containing proteins within a large pool of proteins, e.g., after denaturing or non-denaturing electrophoretic separation of proteins in one-dimensional and two-dimensional gels. LA-ICP-MS can be employed to detect metalloproteins in protein bands or spots separated after gel electrophoresis. MALDI-MS can then be used to identify specific metal-containing proteins in these bands or spots. The combination of these techniques is described in the second section. KW - ICP-Massenspektrometrie KW - Metalle KW - Metallproteide KW - Elektrophorese KW - Gehirn Y1 - 2010 U6 - https://doi.org/10.1039/b916722f IS - 2 SP - 104 EP - 111 PB - Oxford Academic Press ER - TY - JOUR A1 - Osterholt, Tobias A1 - Salber, Dagmar A1 - Matusch, Andreas A1 - Becker, Johanna Sabine A1 - Palm, Christoph T1 - IMAGENA: Image Generation and Analysis BT - An Interactive Software Tool handling LA-ICP-MS Data JF - International Journal of Mass Spectrometry N2 - Metals are involved in many processes of life. They are needed for enzymatic reactions, are involved in healthy processes but also yield diseases if the metal homeostasis is disordered. Therefore, the interest to assess the spatial distribution of metals is rising in biomedical science. Imaging metal (and non-metal) isotopes by laser ablation mass spectrometry with inductively coupled plasma (LA-ICP-MS) requires a special software solution to process raw data obtained by scanning a sample line-by-line. As no software ready to use was available we developed an interactive software tool for Image Generation and Analysis (IMAGENA). Unless optimised for LA-ICP-MS, IMAGENA can handle other raw data as well. The general purpose was to reconstruct images from a continuous list of raw data points, to visualise these images, and to convert them into a commonly readable image file format that can be further analysed by standard image analysis software. The generation of the image starts with loading a text file that holds a data column of every measured isotope. Specifying general spatial domain settings like the data offset and the image dimensions is done by the user getting a direct feedback by means of a preview image. IMAGENA provides tools for calibration and to correct for a signal drift in the y-direction. Images are visualised in greyscale as well a pseudo-colours with possibilities for contrast enhancement. Image analysis is performed in terms of smoothed line plots in row and column direction. KW - LA-ICP-MS KW - ICP-Massenspektrometrie KW - Bilderzeugung KW - Graphische Benutzeroberfläche KW - Image generation KW - Image analysis KW - Graphical user interface Y1 - 2011 U6 - https://doi.org/10.1016/j.ijms.2011.03.010 VL - 307 IS - 1-3 SP - 232 EP - 239 ER - TY - JOUR A1 - Dammers, Jürgen A1 - Axer, Markus A1 - Gräßel, David A1 - Palm, Christoph A1 - Zilles, Karl A1 - Amunts, Katrin A1 - Pietrzyk, Uwe T1 - Signal enhancement in polarized light imaging by means of independent component analysis JF - NeuroImage N2 - Polarized light imaging (PLI) enables the evaluation of fiber orientations in histological sections of human postmortem brains, with ultra-high spatial resolution. PLI is based on the birefringent properties of the myelin sheath of nerve fibers. As a result, the polarization state of light propagating through a rotating polarimeter is changed in such a way that the detected signal at each measurement unit of a charged-coupled device (CCD) camera describes a sinusoidal signal. Vectors of the fiber orientation defined by inclination and direction angles can then directly be derived from the optical signals employing PLI analysis. However, noise, light scatter and filter inhomogeneities interfere with the original sinusoidal PLI signals. We here introduce a novel method using independent component analysis (ICA) to decompose the PLI images into statistically independent component maps. After decomposition, gray and white matter structures can clearly be distinguished from noise and other artifacts. The signal enhancement after artifact rejection is quantitatively evaluated in 134 histological whole brain sections. Thus, the primary sinusoidal signals from polarized light imaging can be effectively restored after noise and artifact rejection utilizing ICA. Our method therefore contributes to the analysis of nerve fiber orientation in the human brain within a micrometer scale. KW - Bildgebendes Verfahren KW - Polarisiertes Licht KW - Signalverarbeitung KW - Signaltrennung KW - Komponentenanalyse KW - Gehirn Y1 - 2010 U6 - https://doi.org/10.1016/j.neuroimage.2009.08.059 VL - 49 IS - 2 SP - 1241 EP - 1248 PB - Elsevier ER -