TY - JOUR A1 - Maier, Johannes A1 - Perret, Jerome A1 - Simon, Martina A1 - Schmitt-Rüth, Stephanie A1 - Wittenberg, Thomas A1 - Palm, Christoph T1 - Force-feedback assisted and virtual fixtures based K-wire drilling simulation JF - Computers in Biology and Medicine N2 - One common method to fix fractures of the human hand after an accident is an osteosynthesis with Kirschner wires (K-wires) to stabilize the bone fragments. The insertion of K-wires is a delicate minimally invasive surgery, because surgeons operate almost without a sight. Since realistic training methods are time consuming, costly and insufficient, a virtual-reality (VR) based training system for the placement of K-wires was developed. As part of this, the current work deals with the real-time bone drilling simulation using a haptic force-feedback device. To simulate the drilling, we introduce a virtual fixture based force-feedback drilling approach. By decomposition of the drilling task into individual phases, each phase can be handled individually to perfectly control the drilling procedure. We report about the related finite state machine (FSM), describe the haptic feedback of each state and explain, how to avoid jerking of the haptic force-feedback during state transition. The usage of the virtual fixture approach results in a good haptic performance and a stable drilling behavior. This was confirmed by 26 expert surgeons, who evaluated the virtual drilling on the simulator and rated it as very realistic. To make the system even more convincing, we determined real drilling feed rates through experimental pig bone drilling and transferred them to our system. Due to a constant simulation thread we can guarantee a precise drilling motion. Virtual fixtures based force-feedback calculation is able to simulate force-feedback assisted bone drilling with high quality and, thus, will have a great potential in developing medical applications. KW - Handchirurgie KW - Osteosynthese KW - Operationstechnik KW - Lernprogramm KW - Virtuelle Realität KW - Medical training system KW - Virtual fixtures KW - Virtual reality KW - Force-feedback haptic KW - Minimally invasive hand surgery KW - K-wire drilling Y1 - 2019 U6 - https://doi.org/10.1016/j.compbiomed.2019.103473 N1 - Corresponding author: Christoph Palm VL - 114 SP - 1 EP - 10 PB - Elsevier ER - TY - GEN A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph ED - Handels, Heinz ED - Deserno, Thomas M. ED - Maier, Andreas ED - Maier-Hein, Klaus H. ED - Palm, Christoph ED - Tolxdorff, Thomas T1 - Abstract: Imitating Human Soft Tissue with Dual-Material 3D Printing T2 - Bildverarbeitung für die Medizin 2019, Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 17. bis 19. März 2019 in Lübeck N2 - Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. KW - Handchirurgie KW - 3D-Druck KW - Lernprogramm KW - HaptiVisT Y1 - 2019 SN - 978-3-658-25325-7 U6 - https://doi.org/10.1007/978-3-658-25326-4_48 SP - 218 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph T1 - Imitating human soft tissue on basis of a dual-material 3D print using a support-filled metamaterial to provide bimanual haptic for a hand surgery training system JF - Quantitative Imaging in Medicine and Surgery N2 - Background: Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D-printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. Methods: The goal of this experiment is to imitate human soft tissue with its haptic and elasticity for a realistic hand phantom fabrication, using only a dual-material 3D printer and support-material-filled metamaterial between skin and bone. We present our workflow to generate lattice structures between hard bone and soft skin with iterative cube edge (CE) or cube face (CF) unit cells. Cuboid and finger shaped sample prints with and without inner hard bone in different lattice thickness are constructed and 3D printed. Results: The most elastic available rubber-like material is too firm to imitate soft tissue. By reducing the amount of rubber in the inner volume through support material (SUP), objects become significantly softer. Without metamaterial, after disintegration, the SUP can be shifted through the volume and thus the body loses its original shape. Although the CE design increases the elasticity, it cannot restore the fabric form. In contrast to CE, the CF design increases not only the elasticity but also guarantees a local limitation of the SUP. Therefore, the body retains its shape and internal bones remain in its intended place. Various unit cell sizes, lattice thickening and skin thickness regulate the rubber material and SUP ratio. Test prints with higher SUP and lower rubber material percentage appear softer and vice versa. This was confirmed by an expert surgeon evaluation. Subjects adjudged pure rubber-like material as too firm and samples only filled with SUP or lattice structure in CE design as not suitable for imitating tissue. 3D-printed finger samples in CF design were rated as realistic compared to the haptic of human tissue with a good palpable bone structure. Conclusions: We developed a new dual-material 3D print technique to imitate soft tissue of the human hand with its haptic properties. Blowy SUP is trapped within a lattice structure to soften rubber-like 3D print material, which makes it possible to reproduce a realistic replica of human hand soft tissue. KW - Dual-material 3D printing KW - Hand surgery training KW - Metamaterial KW - Support material KW - Tissue-imitating hand phantom KW - Handchirurgie KW - 3D-Druck KW - Biomaterial KW - Lernprogramm Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-979 N1 - Corresponding author: Christoph Palm VL - 9 IS - 1 SP - 30 EP - 42 PB - AME Publishing Company ER - TY - JOUR A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph T1 - Optically tracked and 3D printed haptic phantom hand for surgical training system JF - Quantitative Imaging in Medicine and Surgery N2 - Background: For surgical fixation of bone fractures of the human hand, so-called Kirschner-wires (K-wires) are drilled through bone fragments. Due to the minimally invasive drilling procedures without a view of risk structures like vessels and nerves, a thorough training of young surgeons is necessary. For the development of a virtual reality (VR) based training system, a three-dimensional (3D) printed phantom hand is required. To ensure an intuitive operation, this phantom hand has to be realistic in both, its position relative to the driller as well as in its haptic features. The softest 3D printing material available on the market, however, is too hard to imitate human soft tissue. Therefore, a support-material (SUP) filled metamaterial is used to soften the raw material. Realistic haptic features are important to palpate protrusions of the bone to determine the drilling starting point and angle. An optical real-time tracking is used to transfer position and rotation to the training system. Methods: A metamaterial already developed in previous work is further improved by use of a new unit cell. Thus, the amount of SUP within the volume can be increased and the tissue is softened further. In addition, the human anatomy is transferred to the entire hand model. A subcutaneous fat layer and penetration of air through pores into the volume simulate shiftability of skin layers. For optical tracking, a rotationally symmetrical marker attached to the phantom hand with corresponding reference marker is developed. In order to ensure trouble-free position transmission, various types of marker point applications are tested. Results: Several cuboid and forearm sample prints lead to a final 30 centimeter long hand model. The whole haptic phantom could be printed faultless within about 17 hours. The metamaterial consisting of the new unit cell results in an increased SUP share of 4.32%. Validated by an expert surgeon study, this allows in combination with a displacement of the uppermost skin layer a good palpability of the bones. Tracking of the hand marker in dodecahedron design works trouble-free in conjunction with a reference marker attached to the worktop of the training system. Conclusions: In this work, an optically tracked and haptically correct phantom hand was developed using dual-material 3D printing, which can be easily integrated into a surgical training system. KW - Handchirurgie KW - 3D-Druck KW - Lernprogramm KW - Zielverfolgung KW - HaptiVisT KW - Dual-material 3D printing KW - hand surgery training KW - metamaterial KW - tissue imitating phantom hand Y1 - 2020 U6 - https://doi.org/10.21037/qims.2019.12.03 N1 - Corresponding author: Christoph Palm VL - 10 IS - 02 SP - 340 EP - 455 PB - AME Publishing Company CY - Hong Kong, China ER - TY - CHAP A1 - Maier, Johannes A1 - Huber, Michaela A1 - Katzky, Uwe A1 - Perret, Jerome A1 - Wittenberg, Thomas A1 - Palm, Christoph T1 - Force-Feedback-assisted Bone Drilling Simulation Based on CT Data T2 - Bildverarbeitung für die Medizin 2018; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 11. bis 13. März 2018 in Erlangen N2 - In order to fix a fracture using minimally invasive surgery approaches, surgeons are drilling complex and tiny bones with a 2 dimensional X-ray as single imaging modality in the operating room. Our novel haptic force-feedback and visual assisted training system will potentially help hand surgeons to learn the drilling procedure in a realistic visual environment. Within the simulation, the collision detection as well as the interaction between virtual drill, bone voxels and surfaces are important. In this work, the chai3d collision detection and force calculation algorithms are combined with a physics engine to simulate the bone drilling process. The chosen Bullet-Physics-Engine provides a stable simulation of rigid bodies, if the collision model of the drill and the tool holder is generated as a compound shape. Three haptic points are added to the K-wire tip for removing single voxels from the bone. For the drilling process three modes are proposed to emulate the different phases of drilling in restricting the movement of a haptic device. KW - Handchirurgie KW - Osteosynthese KW - Simulation KW - Lernprogramm Y1 - 2018 U6 - https://doi.org/10.1007/978-3-662-56537-7_78 SP - 291 EP - 296 PB - Springer CY - Berlin ER - TY - CHAP A1 - Eixelberger, Thomas A1 - Wittenberg, Thomas A1 - Perret, Jerome A1 - Katzky, Uwe A1 - Simon, Martina A1 - Schmitt-Rüth, Stephanie A1 - Hofer, Mathias A1 - Sorge, M. A1 - Jacob, R. A1 - Engel, Felix B. A1 - Gostian, A. A1 - Palm, Christoph A1 - Franz, Daniela T1 - A haptic model for virtual petrosal bone milling T2 - 17. Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassistierte Chirurgie (CURAC2018), Tagungsband, 2018, Leipzig, 13.-15. September N2 - Virtual training of bone milling requires realtime and realistic haptics of the interaction between the ”virtual mill” and a ”virtual bone”. We propose an exponential abrasion model between a virtual one and the mill bit and combine it with a coarse representation of the virtual bone and the mill shaft for collision detection using the Bullet Physics Engine. We compare our exponential abrasion model to a widely used linear abrasion model and evaluate it quantitatively and qualitatively. The evaluation results show, that we can provide virtual milling in real-time, with an abrasion behavior similar to that proposed in the literature and with a realistic feeling of five different surgeons. KW - Osteosynthese KW - Simulation KW - Lernprogramm Y1 - 2018 UR - https://www.curac.org/images/advportfoliopro/images/CURAC2018/CURAC 2018 Tagungsband.pdf VL - 17 SP - 214 EP - 219 ER - TY - CHAP A1 - Franz, Daniela A1 - Katzky, Uwe A1 - Neumann, Sabine A1 - Perret, Jerome A1 - Hofer, Mathias A1 - Huber, Michaela A1 - Schmitt-Rüth, Stephanie A1 - Haug, Sonja A1 - Weber, Karsten A1 - Prinzen, Martin A1 - Palm, Christoph A1 - Wittenberg, Thomas T1 - Haptisches Lernen für Cochlea Implantationen BT - Konzept - HaptiVisT Projekt T2 - 15. Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassistierte Chirurgie (CURAC2016), Tagungsband, 2016, Bern, 29.09. - 01.10. N2 - Die Implantation eines Cochlea Implantates benötigt einen chirurgischen Zugang im Felsenbein und durch die Paukenhöhle des Patienten. Der Chirurg hat eine eingeschränkte Sicht im Operationsgebiet, die weiterhin viele Risikostrukturen enthält. Um eine Cochlea Implantation sicher und fehlerfrei durchzuführen, ist eine umfangreiche theoretische und praktische (teilweise berufsbegleitende) Fortbildung sowie langjährige Erfahrung notwendig. Unter Nutzung von realen klinischen CT/MRT Daten von Innen- und Mittelohr und der interaktiven Segmentierung der darin abgebildeten Strukturen (Nerven, Cochlea, Gehörknöchelchen,...) wird im HaptiVisT Projekt ein haptisch-visuelles Trainingssystem für die Implantation von Innen- und Mittelohr-Implantaten realisiert, das als sog. „Serious Game“ mit immersiver Didaktik gestaltet wird. Die Evaluierung des Demonstrators hinsichtlich Zweckmäßigkeit erfolgt prozessbegleitend und ergebnisorientiert, um mögliche technische oder didaktische Fehler vor Fertigstellung des Systems aufzudecken. Drei zeitlich versetzte Evaluationen fokussieren dabei chirurgisch-fachliche, didaktische sowie haptisch-ergonomische Akzeptanzkriterien. KW - Virtuelles Training KW - Haptisches Feedback KW - Gamification in der Medizin KW - Cochlea-Implantat KW - Operationstechnik KW - Simulation KW - Haptische Feedback-Technologie KW - Lernprogramm Y1 - 2016 UR - https://curac.org/images/advportfoliopro/images/CURAC2016/CURAC%202016%20Tagungsband.pdf SP - 21 EP - 26 ER -