TY - JOUR A1 - Monkman, Gareth J. A1 - Striegl, Birgit A1 - Prem, Nina A1 - Sindersberger, Dirk T1 - Electrical Properties of Magnetoactive Boron‐Organo‐Silicon Oxide Polymers JF - Macromolecular Chemistry and Physics N2 - The electrical properties of rheopectic magnetoactive composites comprising boron-organo-silicon oxide dielectric matrices containing carbonyl iron microparticles are presented for the first time. The increase in interfacial magnetocapacitance is seen to greatly exceed that experienced when using conventional elastomeric matrices such as polydimethylsiloxane. In addition to the increase in capacitance, a simultaneous and sharp decrease in the parallel electrical resistance over several orders of magnitude is also observed. The effects are time dependent but repeatable. Potential applications include magnetically controlled frequency dependent devices, magnetic sensor systems, weighting elements for neural networks, etc. Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-26488 N1 - Corresponding author: Gareth J. Monkman VL - 221 IS - 4 SP - 1 EP - 8 PB - Wiley ER - TY - JOUR A1 - Auer, Simon A1 - Schiebl, Jonas A1 - Iversen, Kristoffer A1 - Subhash Chander, Divyaksh A1 - Damsgaard, Michael A1 - Dendorfer, Sebastian T1 - Biomechanical assessment of the design and efficiency of occupational exoskeletons with the AnyBody Modeling System JF - Zeitschrift für Arbeitswissenschaften N2 - Exoskeletons were invented over 100 years ago but have only become popular in the last two decades, especially in the working industry as they can decrease work-related loads significantly. The most often used exoskeletons are for the lower back and shoulder since these are commonly affected body regions. All devices have in common that their purpose is to reduce internal loads of vulnerable body regions. Nevertheless, there is still little understanding on how biomechanical loading in the human body changes when exoskeletons are used. Therefore, further analyses are needed. A promising candidate for these are musculoskeletal models, which are based on an inverse dynamics approach and can calculate external parameters such as ground reaction forces or other interaction forces as well as internal parameters such as joint reaction forces or muscle activities. The various examples in the literature show that these models are increasingly used for assessing the biomechanical effects of exoskeletons on the human body. Furthermore, musculoskeletal models can calculate biomechanical loadings of humans with and without exoskeletons for all kinds of applications and allow an evaluation of their purpose. Practical Relevance: This article highlights the possibilities of musculoskeletal models for assessing the design and efficiency of occupational exoskeletons. Several practical use cases are described along with distinct descriptions of common implications of musculoskeletal and exoskeleton modeling. KW - Biomechanics KW - Ergonomics KW - Motion capture KW - Inverse dynamics Y1 - 2022 U6 - https://doi.org/10.1007/s41449-022-00336-4 N1 - Corresponding author: Sebastian Dendorfer VL - 76 IS - 4 SP - 440 EP - 449 PB - Springer Nature ER - TY - JOUR A1 - Melzner, Maximilian A1 - Pfeiffer, Christian A1 - Suess, Franz A1 - Dendorfer, Sebastian T1 - Musculoskeletal simulation of elbow stability for common injury patterns JF - Journal of Orthopaedic Research N2 - Elbow stability is derived from a combination of muscular, ligamentous, and bony structures. After an elbow trauma the stability of the joint is an important decision criterion for the subsequent treatment. The decision regarding non-operative/operative care depends mostly on subjective assessments of medical experts. Therefore, the aim of this study is to use musculoskeletal simulations as an objective assessment tool to investigate the extent to which failure of different stabilizers affects the elbow stability and how these observations correspond to the assessment from clinical practice. A musculoskeletal elbow simulation model was developed for this aim. To investigate the stability of the elbow, varus/valgus moments were applied under 0°, 45°and 90° flexion while the respective cubital angle was analyzed. This was performed for nine different injury scenarios, which were also evaluated for stability by clinical experts. With the results, it can be determined by which injury pattern and under which flexion angle the elbow stability is impaired regarding varus/valgus moments. The scenario with a complete failure of the medial and lateral ligaments and a fracture of the radial head was identified as having the greatest instability. The study presented a numerical determination of elbow stability against varus/valgus moments regarding clinical injury patterns, as well as a comparison of the numerical outcome with experience gained in clinical practice. The numerical predictions agree well with the assessments of the clinical specialists. Thus, the results from musculoskeletal simulation can make an important contribution to a more objective assessment of the elbow stability. KW - AnyBody KW - musculoskeletal simulation KW - elbow stability Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-54819 SN - 1554-527X N1 - Corresponding author: Maximilian Melzner VL - 41 IS - 6 SP - 1356 EP - 1364 PB - Wiley ER - TY - JOUR A1 - Reinker, Lukas A1 - Dendorfer, Sebastian T1 - Evaluation of acceleration patterns during high-impact jumping exercises JF - Gait & Posture Y1 - 2023 U6 - https://doi.org/10.1016/j.gaitpost.2022.11.051 VL - 100 IS - Supplement 1, March SP - 93 EP - 94 PB - Elsevier CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Reinker, Lukas A1 - Bläsing, Dominic A1 - Bierl, Rudolf A1 - Ulbricht, Sabina A1 - Dendorfer, Sebastian T1 - Correlation of Acceleration Curves in Gravitational Direction for Different Body Segments during High-Impact Jumping Exercises JF - sensors N2 - Osteoporosis is a common disease of old age. However, in many cases, it can be very well prevented and counteracted with physical activity, especially high-impact exercises. Wearables have the potential to provide data that can help with continuous monitoring of patients during therapy phases or preventive exercise programs in everyday life. This study aimed to determine the accuracy and reliability of measured acceleration data at different body positions compared to accelerations at the pelvis during different jumping exercises. Accelerations at the hips have been investigated in previous studies with regard to osteoporosis prevention. Data were collected using an IMU-based motion capture system (Xsens) consisting of 17 sensors. Forty-nine subjects were included in this study. The analysis shows the correlation between impacts and the corresponding drop height, which are dependent on the respective exercise. Very high correlations (0.83–0.94) were found between accelerations at the pelvis and the other measured segments at the upper body. The foot sensors provided very weak correlations (0.20–0.27). Accelerations measured at the pelvis during jumping exercises can be tracked very well on the upper body and upper extremities, including locations where smart devices are typically worn, which gives possibilities for remote and continuous monitoring of programs. KW - osteoporosis KW - inertial measurement units KW - wearable motion-tracking sensors KW - high-impact exercisess Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-58217 N1 - Corresponding author: Lukas Reinker N1 - This work was supported by the Bavarian Academic Forum [BayWISS-Verbundkolleg Gesundheit] and the DHZK fond for behavioral cardiovascular diseases [Behaviorale kardiovaskuläre Erkrankungen; grand number: 81Z0400105]. VL - 23 IS - 4 PB - MDPI CY - Basel ER - TY - JOUR A1 - Mühling, Mischa A1 - Sandriesser, Sabrina A1 - Dendorfer, Sebastian A1 - Augat, Peter T1 - Assessment of implant internal stresses under physiological femoral loading: Translation to a simplified bending load model JF - Journal of Biomechanics N2 - The success of surgical treatment for fractures hinges on various factors, notably accurate surgical indication. The process of developing and certifying a new osteosynthesis device is a lengthy and costly process that requires multiple cycles of review and validation. Current methods, however, often rely on predecessor standards rather than physiological loads in specific anatomical locations. This study aimed to determine actual loads experienced by an osteosynthesis plate, exemplified by a standard locking plate for the femoral shaft, utilizing finite elements analysis (FEA) and to obtain the bending moments for implant development standard tests. A protocol was developed, involving the creation and validation of a fractured femur model fixed with a locking plate, mechanical testing, and FEA. The model’s validation demonstrated exceptional accuracy in predicting deformations, and the FEA revealed peak stresses in the fracture bridging zone. Results of a parametric analysis indicate that larger fracture gaps significantly impact implant mechanical behavior, potentially compromising stability. This study underscores the critical need for realistic physiological conditions in implant evaluations, providing an innovative translational approach to identify internal loads and optimize implant designs. In conclusion, this research contributes to enhancing the understanding of implant performance under physiological conditions, promoting improved designs and evaluations in fracture treatments. KW - bone biomechanics KW - finite elements analysis KW - femoral fracture KW - Euler-Bernoulli-Beam-Theory KW - simplified loading model Y1 - 2024 U6 - https://doi.org/10.1016/j.jbiomech.2024.112229 SN - 1873-2380 IS - 112229 PB - Elsevier ER - TY - JOUR A1 - Auer, Simon A1 - Kubowitsch, Simone A1 - Dendorfer, Sebastian T1 - Kombinierter Einfluss von psychologischen und biomechanischen Faktoren auf die muskulären Belastungen beim Fußballspielen JF - Die Orthopädie N2 - When mental stress and musculoskeletal loading interact, the risk for injury increases due to altered body kinematics and increased muscle tension. These changes can be detected with musculoskeletal models, and mental loading and stress must be analyzed at emotional, cognitive, and behavioral levels. To investigate these kinematic and loading changes under stress, competitive athletes were subjected to mental stress during highly dynamic movements, and musculoskeletal models were used to analyze the biomechanical loading. It was shown that under mental stress, independent of the subjective perception, a strong change in muscle forces can occur. Accordingly, competitive athletes should undergo screenings to assess individual movement patterns and promote general stress resilience. N2 - Für Fußballer:innen stellen muskuläre Verletzungen der unteren Extremitäten ein großes Problem dar. Ein Beispiel hierfür liefert die Nationalmannschaftsstürmerin Alexandra Popp, die aufgrund muskulärer Probleme das EM-Finale 2022 in Wembley kurzfristig verpasste. Oftmals stehen gerade hohe Anspannungssituationen in zeitlichem Zusammenhang mit Verletzungen, der Einfluss der psychischen Beanspruchung auf die biomechanischen Belastungen wird jedoch meist nur wenig beachtet. KW - Biologische Modelle KW - Biomechanik KW - Leistungssportler KW - Bewegung KW - Resilienz, psychologische KW - Biological models KW - Biomechanics KW - Elite athletes KW - Movement KW - Resilience, psychological Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-65113 N1 - Corresponding author: Sebastian Dendorfer VL - 52 IS - 11 SP - 1 EP - 6 PB - Springer ER - TY - JOUR A1 - Dendorfer, Sebastian A1 - Gschoßman, Lukas T1 - Hightech in der Rehabiliation JF - BVOU Infobrief: Hightech in Orthopädie und Unfallchirurgie N2 - Aufgrund der steigenden Lebenserwartung und dem damit einhergehenden demographischen Wandel wird der Bedarf an Rehabilitations-Behandlungen in absehbarer Zukunft stark ansteigen. Ein Beispiel für diesen Trend ist die physiotherapeutische Behandlung nach Erhalt einer Knie-Totalendoprothese (Knie-TEP). So gehen Modellrechnungen basierend auf dem Bevölkerungswachstum und der bisherigen Prävalenz von Knie-TEPs davon aus, dass die Anzahl an durchgeführten Eingriffen in einkommensstarken Ländern wie Deutschland weiter zunehmen wird. Weiterhin stoßen traditionelle Rehabilitationsverfahren, gerade in strukturschwachen Regionen, schon heute an ihre Grenzen. Deutlich zu sehen war das während den Hochphasen der aktuellen Covid-19-Pandemie, als der Kontakt zwischen Therapeut*in und Patient*in flächendeckend eingeschränkt war. Eine erhöhte Nachfrage nach neuartigen Reha-Angeboten ist die logische Konsequenz. Innovative Konzepte sind daher dringend notwendig, um die daraus resultierenden technischen, sozialen und ökonomischen Herausforderungen zu bewältigen. Y1 - 2023 UR - https://www.bvou.net/infobrief-1-23/ SN - 2747-5913 IS - 1 SP - 9 EP - 11 PB - BVOU – Berufsverband für Orthopädie und Unfallchirurgie e.V. CY - Berlin ER - TY - JOUR A1 - Rusavy, Zdenek A1 - Cechova, Hana A1 - Dendorfer, Sebastian A1 - Kalis, Vladimir A1 - Ismail, Khaled M. T1 - Is the Finnish grip tight enough? A manometric study of two manual perineal protection techniques JF - Acta Obstetricia et Gynecologica Scandinavica Y1 - 2024 U6 - https://doi.org/10.1111/aogs.15033 PB - Wiley ET - Early view ER - TY - JOUR A1 - Schaeffer, Leon A1 - Herrmann, David A1 - Schratzenstaller, Thomas A1 - Dendorfer, Sebastian A1 - Böhm, Valter T1 - Preliminary theoretical considerations on the stiffness characteristics of a tensegrity joint for the use in dynamic orthoses JF - Journal of Medical Robotics Research N2 - Early motion therapy plays an important role for effective long-term healing of joint injuries. In many cases, conventional dynamic orthoses fail to address the intricate movement possibilities of the underlying joints, limited by their simplistic joint representations, often represented by revolute joints, enabling rotations by only one axis. In this paper, a two-dimensional compliant tensegrity joint for use in biomedical applications is investigated. It consists of two compressed members and five compliant tensioned members. Relative movement possibilities are realized by the intrinsic compliance of the structure. In the development of these systems, the first step is the determination of the static stable equilibrium. This analysis is conducted in this paper by considering the potential energy approach or by using the geometric nonlinear finite element method. The mechanical behavior of the structure is assessed with a specific emphasis on its mechanical compliance. The primary objective of this study is the investigation of the influence of structural parameters on the overall stiffness and movability of the structure. The results underscore the significant effect of member parameters on the stiffness and movability of the compliant tensegrity joint, particularly under varying load magnitudes. These findings provide insights for optimizing the joint’s performance, contributing to its potential application in advanced orthotic and exoskeleton devices. KW - mechanical compliance KW - flexibility ellipsis KW - form-finding KW - tensegrity joint Y1 - 2023 U6 - https://doi.org/10.1142/S2424905X23400081 PB - World Scientific ER - TY - JOUR A1 - Schmitz, Paul A1 - Neumann, Christoph Cornelius A1 - Neumann, Carsten A1 - Nerlich, Michael A1 - Dendorfer, Sebastian T1 - Biomechanical analysis of iliac crest loading following cortico-cancellous bone harvesting JF - Journal of Orthopaedic Surgery and Research N2 - Background Iliac crest bone harvesting is a frequently performed surgical procedure widely used to treat bone defects. The objective of this study is to assess the biomechanical quantities related to risk for pelvic fracture after harvesting an autologous bone graft at the anterior iliac crest. Methods Finite element models with a simulated harvest site (sized 15 × 20 mm, 15 × 35 mm, 30 × 20 mm and 30 × 35 mm) in the iliac wing are created. The relevant loading case is when the ipsilateral leg is lifted off the ground. Musculoskeletal analysis is utilized to compute the muscle and joint forces involved in this motion. These forces are used as boundary conditions for the finite element analyses. Bone tissue stress is analyzed. Results Critical stress peaks are located between the anterior superior iliac spine (ASIS) and the anterior edge of the harvest site. Irrespective of the graft size, the iliac wing does not show any significant stress peaks with the harvest site being 20 to 25 mm posterior to the ASIS. The harvest area itself inhibits the distribution of the forces applied on the ASIS to extend to the posterior iliac wing. This leads to a lack of stress posterior to the harvest site. A balanced stress distribution with no stress peaks appears when the bone graft is taken below the iliac crest. Conclusion A harvest site located at least 20 to 25 mm posterior to the ASIS should be preferred to minimize the risk of iliac fatigue fracture. KW - Bone harvesting KW - Autologous bone graft KW - Iliac crest KW - Fatigue fracture KW - Pelvis KW - ASIS KW - FEA KW - Biomechanical investigation KW - Beckenkammknochen KW - Knochenentnahme KW - Spongiosa KW - Biomechanische Analyse Y1 - 2018 U6 - https://doi.org/10.1186/s13018-018-0822-1 VL - 13 IS - 108 SP - 1 EP - 8 PB - Springer Nature ER - TY - JOUR A1 - Völlner, Florian A1 - Weber, Tim A. A1 - Weber, Markus A1 - Renkawitz, Tobias A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Craiovan, Benjamin T1 - A simple method for determining ligament stiffness during total knee arthroplasty in vivo JF - Scientific Reports N2 - A key requirement in both native knee joints and total knee arthroplasty is a stable capsular ligament complex. However, knee stability is highly individual and ranges from clinically loose to tight. So far, hardly any in vivo data on the intrinsic mechanical of the knee are available. This study investigated if stiffness of the native ligament complex may be determined in vivo using a standard knee balancer. Measurements were obtained with a commercially available knee balancer, which was initially calibrated in vitro. 5 patients underwent reconstruction of the force-displacement curves of the ligament complex. Stiffness of the medial and lateral compartments were calculated to measure the stability of the capsular ligament complex. All force-displacement curves consisted of a non-linear section at the beginning and of a linear section from about 80 N onwards. The medial compartment showed values of 28.4 ± 1.2 N/mm for minimum stiffness and of 39.9 ± 1.1 N/mm for maximum stiffness; the respective values for the lateral compartment were 19.9 ± 0.9 N/mm and 46.6 ± 0.8 N/mm. A commercially available knee balancer may be calibrated for measuring stiffness of knee ligament complex in vivo, which may contribute to a better understanding of the intrinsic mechanical behaviour of knee joints. KW - Biomechanische Analyse KW - Kniegelenkband KW - Steifigkeit Y1 - 2019 U6 - https://doi.org/10.1038/s41598-019-41732-x VL - 9 SP - 1 EP - 8 PB - Nature ER - TY - JOUR A1 - Benditz, Achim A1 - Auer, Simon A1 - Spörrer, J.F. A1 - Wolkerstorfer, S. A1 - Grifka, Joachim A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Regarding loads after spinal fusion, every level should be seen separately: a musculoskeletal analysis JF - European Spine Journal N2 - The number of spinal fusion surgeries is steadily increasing and biomechanical consequences are still in debate. The aim of this study is to provide biomechanical insights into the sagittal balance of the spine and to compare spinal load before and after spinal fusion. METHOD: The joint reaction forces of 52 patients were analyzed in proximo-distal and antero-posterior direction from the levels T12-L1 to L5-S1 using musculoskeletal simulations. RESULTS: In 104 simulations, pre-surgical forces were equal to post-surgical. The levels L4-L5 and T12-L1, however, showed increased spinal forces compression forces with higher sagittal displacement. Improved restauration of sagittal balance was accompanied by lower spinal load. AP shear stress, interestingly decreased with sagittal imbalance. CONCLUSION: Imbalanced spines have a risk of increased compression forces at Th12-L1. L4-L5 always has increased spinal loads. These slides can be retrieved under Electronic Supplementary Material. KW - AnyBody Modeling System KW - Musculoskeletal analysis KW - Sagittal balance KW - Spinal fusion KW - Spine biomechanics KW - Biomechanische Analyse KW - Wirbelsäulenversteifung KW - Vergleichende Anatomie Y1 - 2018 U6 - https://doi.org/10.1007/s00586-018-5476-5 VL - 27 IS - 8 SP - 1905 EP - 1910 PB - Springer-Verlag ER - TY - JOUR A1 - Renkawitz, Tobias A1 - Weber, Tim A. A1 - Dullien, Silvia A1 - Woerner, Michael A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Weber, Markus T1 - Leg length and offset differences above 5 mm after total hip arthroplasty are associated with altered gait kinematics JF - Gait & Posture N2 - We aimed to investigate the relationship between postoperative leg length/offset (LL/OS) reconstruction and gait performance after total hip arthroplasty (THA). In the course of a prospective randomized controlled trial, 60 patients with unilateral hip arthrosis received cementless THA through a minimally-invasive anterolateral surgical approach. One year post-operatively, LL and global OS restoration were analyzed and compared to the contralateral hip on AP pelvic radiographs. The combined postoperative limb length/OS reconstruction of the operated hip was categorized as restored (within 5 mm) or non-restored (more than 5 mm reduction or more than 5 mm increment). The acetabular component inclination, anteversion and femoral component anteversion were evaluated using CT scans of the pelvis and the femur. 3D gait analysis of the lower extremity and patient related outcome measures (HHS, HOOS, EQ-5D) were obtained pre-operatively, six months and twelve months post-operatively by an observer blinded to radiographic results. Component position of cup and stem was comparable between the restored and non-restored group. Combined LL and OS restoration within 5 mm resulted in higher Froude number (p < 0.001), normalized walking speed (p < 0.001) and hip range-of-motion (ROM) (p = 0.004) during gait twelve months postoperatively, whereas gait symmetry was comparable regardless of LL and OS reconstruction at both examinations. Clinical scores did not show any relevant association between the accuracy of LL or OS reconstruction and gait six/twelve months after THA. In summary, postoperative LL/OS discrepancies larger than 5 mm relate to unphysiological gait kinematics within the first year after THA. DRKS00000739, German Clinical Trials Register. KW - THA KW - Leg length KW - Offset KW - Gait analysis KW - Biomechanics Y1 - 2016 U6 - https://doi.org/10.1016/j.gaitpost.2016.07.011 VL - vol. 49 SP - 196 EP - 201 ER - TY - JOUR A1 - Putzer, Michael A1 - Auer, Stefan A1 - Malpica, William A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - A numerical study to determine the effect of ligament stiffness on kinematics of the lumbar spine during flexion JF - BMC Musculoskeletal Disorders N2 - Background There is a wide range of mechanical properties of spinal ligaments documented in literature. Due to the fact that ligaments contribute in stabilizing the spine by limiting excessive intersegmental motion, those properties are of particular interest for the implementation in musculoskeletal models. The aim of this study was to investigate the effect of varying ligament stiffness on the kinematic behaviour of the lumbar spine. Methods A musculoskeletal model with a detailed lumbar spine was modified according to fluoroscopic recordings and corresponding data files of three different subjects. For flexion, inverse dynamics analysis with a variation of the ligament stiffness matrix were conducted. The influence of several degrees of ligament stiffness on the lumbar spine model were investigated by tracking ligament forces, disc forces and resulting moments generated by the ligaments. Additionally, the kinematics of the motion segments were evaluated. Results An increase of ligament stiffness resulted in an increase of ligament and disc forces, whereas the relative change of disc force increased at a higher rate at the L4/L5 level (19 %) than at the L3/L4 (10 %) level in a fully flexed posture. The same behaviour applied to measured moments with 67 % and 45 %. As a consequence, the motion deflected to the lower levels of the lumbar spine and the lower discs had to resist an increase in loading. Conclusions Higher values of ligament stiffness over all lumbar levels could lead to a shift of the loading and the motion between segments to the lower lumbar levels. This could lead to an increased risk for the lower lumbar parts. KW - Lumbar spine KW - Ligament stiffness KW - Musculoskeletal Modeling KW - Biomechanics Y1 - 2016 U6 - https://doi.org/10.1186/s12891-016-0942-x VL - 17 IS - 95 ER - TY - JOUR A1 - Weber, Tim A. A1 - Dendorfer, Sebastian A1 - Bulstra, Sjoerd K. A1 - Grifka, Joachim A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias T1 - Gait six month and one-year after computer assisted Femur First THR vs. conventional THR. Results of a patient- and observer- blinded randomized controlled trial JF - Gait & Posture N2 - A prospective randomized controlled trial is presented that is used to compare gait performance between the computer assisted Femur First (CAS FF) operation method and conventional THR (CON). 60 patients underwent a 3D gait analysis of the lower extremity at pre-operative, 6 months post-operative and twelve months post-operative. Detailed verification experiments were facilitated to ensure the quality of data as well as to avoid over-interpreting of the data. The results confirm a similar data-quality as reported in the literature. Walking speed, range of motion and symmetry thereof improved over the follow-up period, without significant differences between the groups. While all parameters do significantly increase over the follow-up period for both groups, there were no significant differences between them at any given time-point. Patients undergoing CAS FF showed a trend to improved hip flexion angle indicating a possible long-term benefit. KW - Biomechanics KW - Combined anteversion KW - Computer-assisted surgery KW - Femur first KW - Gait analysis Y1 - 2016 U6 - https://doi.org/10.1016/j.gaitpost.2016.06.035 VL - vol. 49 SP - 418 EP - 425 ER - TY - JOUR A1 - Renkawitz, Tobias A1 - Weber, Markus A1 - Springorum, H.-R. A1 - Sendtner, E. A1 - Woerner, Michael A1 - Ulm, K. A1 - Weber, Tim A1 - Grifka, Joachim T1 - Impingement-free range of motion, cup coverage and early clinical results between femur first navigation and conventional total hip arthroplasty: a randomised controlled trial JF - Journal of Bone & Joint Surgery N2 - We report the kinematic and early clinical results of a patient- and observer-blinded randomised controlled trial in which CT scans were used to compare potential impingement-free range of movement (ROM) and acetabular component cover between patients treated with either the navigated 'femur-first' total hip arthroplasty (THA) method (n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75). The Hip Osteoarthritis Outcome Score, the Harris hip score, the Euro-Qol-5D and the Mancuso THA patient expectations score were assessed at six weeks, six months and one year after surgery. A total of 48 of the patients (84%) in the navigated 'femur-first' group and 43 (65%) in the conventional group reached all the desirable potential ROM boundaries without prosthetic impingement for activities of daily living (ADL) in flexion, extension, abduction, adduction and rotation (p = 0.016). Acetabular component cover and surface contact with the host bone were > 87% in both groups. There was a significant difference between the navigated and the conventional groups' Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated 'femur-first' technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups. KW - combined anteversion KW - computer-assisted orthopaedic surgery KW - THA KW - Hüftgelenkprothese KW - Operationstechnik KW - Computerunterstütztes Verfahren KW - Beweglichkeit Y1 - 2015 U6 - https://doi.org/10.1302/0301-620X.97B7.34729 VL - 97-B SP - 890 EP - 898 ER - TY - JOUR A1 - Weber, Markus A1 - Weber, Tim A. A1 - Woerner, Michael A1 - Craiovan, Benjamin A1 - Worlicek, Michael A1 - Winkler, Sebastian A1 - Grifka, Joachim A1 - Renkawitz, Tobias T1 - The impact of standard combined anteversion definitions on gait and clinical outcome within one year after total hip arthroplasty JF - International Orthopaedics N2 - Different target areas within the concept of combined cup and stem anteversion have been published for total hip arthroplasty (THA). We asked whether component positioning according to eight standard combined anteversion rules is associated with (1) more physiological gait patterns, (2) higher improvement of gait variables and (3) better clinical outcome after THA.In a prospective clinical study, 60 patients received cementless THA through an anterolateral MIS approach in a lateral decubitus position. Six weeks postoperatively, implant position was analysed using 3D-CT by an independent external institute. Preoperatively, six and 12 months postoperatively range of motion, normalized walking speed and hip flexion symmetry index were measured using 3D motion-capture gait analysis. Patient-related outcome measures (HHS, HOOS, EQ-5D) were obtained by an observer blinded to 3D-CT results. Eight combined anteversion definitions and Lewinnek's "safe zone" were evaluated regarding their impact on gait patterns and clinical outcome.Combined cup and stem anteversion according to standard combined anteversion definitions as well as cup placement within Lewinnek's "safe zone" did not influence range of motion, normalized walking speed and/or hip flexion symmetry index six and 12 months after THA. Similarly, increase of gait parameters within the first year after THA was comparable between all eight combined anteversion rules. Clinical outcome measures like HHS, HOOS and EQ-5D did not show any benefit for either of the combined anteversion definitions.Standard combined cup and stem anteversion rules do not improve postoperative outcome as measured by gait analysis and clinical scores within one year after THA. KW - Total hip athroplasty KW - Combined anteversion KW - Outcome KW - Gait analysis KW - Hüftgelenkprothese KW - Bewegungsanalyse KW - Gehen KW - Funktionelle Anatomie Y1 - 2015 U6 - https://doi.org/10.1007/s00264-015-2777-8 VL - 39 IS - 12 SP - 2323 EP - 2333 ER - TY - JOUR A1 - Ignasiak, Dominika A1 - Dendorfer, Sebastian A1 - Ferguson, Stephen J. T1 - Thoracolumbar spine model with articulated ribcage for the prediction of dynamic spinal loading JF - Journal of Biomechanics N2 - Musculoskeletal modeling offers an invaluable insight into the spine biomechanics. A better understanding of thoracic spine kinetics is essential for understanding disease processes and developing new prevention and treatment methods. Current models of the thoracic region are not designed for segmental load estimation, or do not include the complex construct of the ribcage, despite its potentially important role in load transmission. In this paper, we describe a numerical musculoskeletal model of the thoracolumbar spine with articulated ribcage, modeled as a system of individual vertebral segments, elastic elements and thoracic muscles, based on a previously established lumbar spine model and data from the literature. The inverse dynamics simulations of the model allow the prediction of spinal loading as well as costal joints kinetics and kinematics. The intradiscal pressure predicted by the model correlated well (R2=0.89) with reported intradiscal pressure measurements, providing a first validation of the model. The inclusion of the ribcage did not affect segmental force predictions when the thoracic spine did not perform motion. During thoracic motion tasks, the ribcage had an important influence on the predicted compressive forces and muscle activation patterns. The compressive forces were reduced by up to 32%, or distributed more evenly between thoracic vertebrae, when compared to the predictions of the model without ribcage, for mild thoracic flexion and hyperextension tasks, respectively. The presented musculoskeletal model provides a tool for investigating thoracic spine loading and load sharing between vertebral column and ribcage during dynamic activities. Further validation for specific applications is still necessary. KW - Inverse dynamics KW - Musculoskeletal model KW - Thoracolumbar spine KW - Brustwirbelsäule KW - Brustkorb KW - Biomechanik KW - Mechanische Belastung KW - Prognose Y1 - 2016 U6 - https://doi.org/10.1016/j.jbiomech.2015.10.010 VL - vol. 49 IS - 6 SP - 959 EP - 966 PB - Elsevier Science ER - TY - JOUR A1 - Weber, Tim A. A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias ED - Takagi, Michiaki T1 - Does Computer-Assisted Femur First THR Improve Musculoskeletal Loading Conditions? JF - BioMed Research International N2 - We have developed a novel, computer-assisted operation method for minimal-invasive total hip replacement (THR) following the concept of “femur first/combined anteversion,” which incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position (CAS FF). The purpose of this study is to assess whether the hip joint reaction forces and patient’s gait parameters are being improved by CAS FF in relation to conventional THR (CON). We enrolled 60 patients (28 CAS FF/32 CON) and invited them for gait analysis at three time points (preoperatively, postop six months, and postop 12 months). Data retrieved from gait analysis was processed using patient-specific musculoskeletal models. The target parameters were hip reaction force magnitude (hrf), symmetries, and orientation with respect to the cup. Hrf in the CAS FF group were closer to a young healthy normal. Phase-shift symmetry showed an increase in the CAS FF group. Hrf orientation in the CAS FF group was closer to optimum, though no edge or rim-loading occurred in the CON group as well. The CAS FF group showed an improved hrf orientation in an early stage and a trend to an improved long-term outcome. KW - Hüftgelenkprothese KW - Operationstechnik KW - Computerunterstütztes Verfahren KW - Bewegungsapparat KW - Mechanische Belastung Y1 - 2015 U6 - https://doi.org/10.1155/2015/625317 VL - 2015 SP - ID 625317 ER - TY - JOUR A1 - Weber, Tim A1 - Al-Munajjed, Amir Andreas A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian A1 - Renkawitz, Tobias T1 - Influence of minimally invasive total hip replacement on hip reaction forces and their orientations JF - Journal of Orthopaedic Research N2 - Minimally invasive surgery (MIS) is becoming increasingly popular. Supporters claim that the main advantages of MIS total hip replacement (THR) are less pain and a faster rehabilitation and recovery. Critics claim that safety and efficacy of MIS are yet to be determined. We focused on a biomechanical comparison between surgical standard and MIS approaches for THR during the early recovery of patients. A validated, parameterized musculoskeletal model was set to perform a squat of a 50th percentile healthy European male. A bilateral motion was chosen to investigate effects on the contralateral side. Surgical approaches were simulated by excluding the incised muscles from the computations. Resulting hip reaction forces and their symmetry and orientation were analyzed. MIS THR seemed less influential on the symmetry index of hip reaction forces between the operated and nonoperated leg when compared to the standard lateral approach. Hip reaction forces at peak loads of the standard transgluteal approach were 24% higher on the contralateral side when compared to MIS approaches. Our results suggest that MIS THR contributes to a greater symmetry of hip reaction forces in absolute value as well as force-orientation following THR. KW - THA KW - THR KW - Biomechanics KW - Conventional surgery KW - Early recovery KW - Hüftgelenkprothese KW - Minimal-invasive Chirurgie KW - Biomechanik Y1 - 2014 U6 - https://doi.org/10.1002/jor.22710 VL - 32 IS - 12 SP - 1680 EP - 1687 ER - TY - JOUR A1 - Putzer, Michael A1 - Ehrlich, Ingo A1 - Rasmussen, John A1 - Gebbeken, Norbert A1 - Dendorfer, Sebastian T1 - Sensitivity of lumbar spine loading to anatomical parameters JF - Journal of Biomechanics N2 - Musculoskeletal simulations of lumbar spine loading rely on a geometrical representation of the anatomy. However, this data has an inherent inaccuracy. This study evaluates the influence of defined geometrical parameters on lumbar spine loading utilising five parametrised musculoskeletal lumbar spine models for four different postures. The influence of the dimensions of vertebral body, disc, posterior parts of the vertebrae as well as the curvature of the lumbar spine was studied. Additionally, simulations with combinations of selected parameters were conducted. Changes in L4/L5 resultant joint force were used as outcome variable. Variations of the vertebral body height, disc height, transverse process width and the curvature of the lumbar spine were the most influential. These parameters can be easily acquired from X-rays and should be used to morph a musculoskeletal lumbar spine model for subject-specific approaches with respect to bone geometry. Furthermore, the model was very sensitive to uncommon configurations and therefore, it is advised that stiffness properties of discs and ligaments should be individualised. KW - Musculoskeletal simulation KW - Lumbar spine KW - Parameter study KW - Vertebra KW - Wirbelsäule KW - Belastung KW - Simulation Y1 - 2015 U6 - https://doi.org/10.1016/j.jbiomech.2015.11.003 VL - 49 IS - 6 SP - 953 EP - 958 PB - Elsevier Science ER - TY - JOUR A1 - Dendorfer, Sebastian A1 - Weber, Tim A1 - Kennedy, O. T1 - Musculoskeletal modeling for hip replacement outcome analyses and other applications JF - The Journal of the American Academy of Orthopaedic Surgeons KW - Hüftgelenkprothese KW - Bewegungsapparat KW - Simulation Y1 - 2014 U6 - https://doi.org/10.5435/JAAOS-22-04-268 VL - 22 IS - 4 SP - 268 EP - 269 ER - TY - JOUR A1 - Penzkofer, Rainer A1 - Barnsteiner, K. A1 - Dendorfer, Sebastian T1 - The influence of age, shoe type and kicking direction on the severity of head trauma JF - Journal of Forensic Biomechanics N2 - In the last few years, increasingly kicks to the head were observed as a criminal offense. This study examined the influence of age, shoe type and kicking direction on the severity of head trauma. Male test persons were divided into two groups “Old” and “Young”. Both groups were equipped with light sneakers and combat boots. A standard laboratory crash dummy was used to simulate the victim’s body. First, the dummy’s head, free floating above the ground, was kicked vertically. Second, the dummy’s head was kicked horizontally. Established injury criteria were used to quantify the injury risk. No influence concerning the type of foot wear and no difference between the groups “Old” and “Young” could be found. For all analyses, kicking vertically generally lead to a higher risk for the subject compared to kicking horizontally. In this study, only the integral effect of the kicks could be analyzed. A detailed injury pattern cannot directly be derived from the data. Nevertheless, the presented data show the massive potential of injuries associated with head kicks. KW - Head trauma KW - Biomechanics KW - Kicks KW - Kopfverletzung KW - Schädel-Hirn-Trauma KW - Einflussgröße Y1 - 2014 UR - https://www.longdom.org/open-access/the-influence-of-age-shoe-type-and-kicking-direction-on-the-severity-of-head-trauma-2090-2697-1000116.pdf U6 - https://doi.org/10.4172/2090-2697.1000116 VL - 5 IS - 1 ER - TY - JOUR A1 - De Pieri, Enrico A1 - Atzori, Federica A1 - Ferguson, Stephen J. A1 - Dendorfer, Sebastian A1 - Leunig, Michael A1 - Aepli, Martin T1 - Contact force path in total hip arthroplasty: effect of cup medialisation in a whole-body simulation JF - HIP International N2 - Background: Cup medialisation down to the true acetabular floor in total hip arthroplasty with a compensatory femoral offset increase seems to be mechanically advantageous for the abductor muscles due to the relocation of the lever arms (body weight lever arm decreased, abductor lever arm increased). However, limited information is currently available about the effects of this reconstruction type at the head cup interface, compared to an anatomical reconstruction that maintains the natural lever arms. Through a whole-body simulation analysis, we compared medialised versus anatomical reconstruction in THA to analyse the effects on: (1) contact force magnitude at the head cup interface; (2) contact force path in the cup; and (3) abductor activity. Methods: Musculoskeletal simulations were performed to calculate the above-mentioned parameters using inverse dynamics analysis. The differences between the virtually implanted THAs were calculated to compare the medialised versus anatomical reconstruction. Results: Cup medialisation with compensatory femoral offset increase led to: (1) a reduction in contact force magnitude at the head cup interface up to 6.6%; (2) a similar contact force path in the cup in terms of sliding distance and aspect ratio; and (3) a reduction in abductor activity up to 17.2% (gluteus medius). Conclusions: In our opinion, these potential biomechanical gains do not generally justify a fully medialised reconstruction, especially in younger patients that are more likely to undergo revision surgery in their lifetime. Cup medialisation should be performed until sufficient press fit and bony coverage of a properly sized and oriented cup can be achieved. KW - Cup medialisation KW - femoral offset KW - hip contact force KW - total hip anthroplasty KW - total hip replacement KW - Hüftgelenkprothese KW - Kontaktkraft KW - Biomechanische Analyse KW - Simulation Y1 - 2020 U6 - https://doi.org/10.1177/1120700020917321 VL - 31 IS - 5 SP - 624 EP - 631 PB - Sage ER - TY - JOUR A1 - Aurbach, Maximilian A1 - Spicka, Jan A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Evaluation of musculoskeletal modelling parameters of the shoulder complex during humeral abduction above 90° JF - Journal of Biomechanics N2 - Based on electromyographic data and force measurements within the shoulder joint, there is an indication that muscle and resulting joint reaction forces keep increasing over an abduction angle of 90°. In inverse dynamics models, no single parameter could be attributed to simulate this force behaviour accordingly. The aim of this work is to implement kinematic, kinetic and muscle model modifications to an existing model of the shoulder (AnyBody™) and assess their single and combined effects during abduction up to 140° humeral elevation. The kinematics and the EMG activity of 10 test subjects were measured during humeral abduction. Six modifications were implemented in the model: alternative wrapping of the virtual deltoid muscle elements, utilization of a three element Hill model, strength scaling, motion capture driven clavicle elevation/protraction, translation of the GH joint in dependency of the acting forces and an alteration of the scapula/clavicle rhythm. From the six modifications, 16 different combinations were considered. Parameter combinations with the Hill model changed the resultant GH joint reaction force and led to an increase in force during abduction of the humerus above 90°. Under the premise of muscle activities and forces within the GH joint rising after 90° of humeral abduction, we propose that the Hill type muscle model is a crucial parameter for accurately modelling the shoulder. Furthermore, the outcome of this study indicates that the Hill model induces the co-contraction of the muscles of the shoulder without the need of an additional stability criterion for an inverse dynamics approach. KW - Shoulder joint KW - Musculoskeletal modelling KW - EMG KW - Glenohumeral joint reaction force KW - Muscle model KW - Schultergelenk KW - Bewegungsapparat KW - Biomechanik KW - Simulation Y1 - 2020 U6 - https://doi.org/10.1016/j.jbiomech.2020.109817 VL - 106 IS - June PB - Elsevier ER - TY - JOUR A1 - Aurbach, Maximilian A1 - Špička, Jan A1 - Süß, Franz A1 - Vychytil, J. A1 - Havelková, Leonard A1 - Ryba, T. A1 - Dendorfer, Sebastian T1 - Torus obstacle method as a wrapping approach of the deltoid muscle group for humeral abduction in musculoskeletal simulation JF - Journal of Biomechanics N2 - Musculoskeletal models of the shoulder complex are valuable research aids to investigate tears of the supraspinatus and the resulting mechanical impact during abduction of the humerus. One of the major contributors to this motion is the deltoid muscle group and for this, an accurate modeling of the lines of action is indispensable. The aim of this work was to utilize a torus obstacle wrapping approach for the deltoids of an existing shoulder model and assess the feasibility of the approach during humeral abduction. The shoulder model from the AnyBody™ modeling system was used as a platform. The size of the tori is based on a magnetic resonance imaging (MRI) approach and several kinematic couplings are implemented to determine the trajectories of the tori during abduction. To assess the model behavior, the moment arms of the virtual muscle elements and the resultant glenohumeral joint reaction force (GHJF) were compared with reference data from the literature during abduction of the humerus in the range 20°–120°. The root mean square error for the anterior, lateral and posterior part between the simulated muscle elements and reference data from the literature was 3.9, 1.7 and 5.8 mm, respectively. The largest deviation occurred on the outer elements of the muscle groups, with 12.6, 10.4 and 20.5 mm, respectively. During abduction, there is no overlapping of the muscle elements and these are in continuous contact with the torus obstacles, thus enabling a continuous force transmission. This results in a rising trend of the resultant GHJF. The torus obstacle approach as a wrapping method for the deltoid muscles provides a guided muscle pathing by simultaneously approximating the curvature of the deltoid muscle. The results from the comparison of the simulated moment arms and the resultant GHJF are in accordance with those in the literature in the range 20°–120° of abduction. Although this study shows the strength of the torus obstacle as a wrapping approach, the method of fitting the tori according to MRI data was not suitable. A cadaver study is recommended to better validate and mathematically describe the torus approach. KW - Muscoloskeletal model KW - AnyBody Modeling System KW - MRI KW - Shoulder joint complex KW - Muscle trajectory KW - Torus KW - Wrapping Y1 - 2020 U6 - https://doi.org/10.1016/j.jbiomech.2020.109864 VL - 109 IS - August PB - Elsevier ER - TY - JOUR A1 - Weber, Markus A1 - Suess, Franz A1 - Jerabek, Seth A1 - Meyer, Matthias A1 - Grifka, Joachim A1 - Renkawitz, Tobias A1 - Dendorfer, Sebastian T1 - Kinematic pelvic tilt during gait alters functional cup position in total hip arthroplasty JF - Journal of Orthopaedic Research N2 - Static pelvic tilt impacts functional cup position in total hip arthroplasty (THA). In the current study we investigated the effect of kinematic pelvic changes on cup position. In the course of a prospective controlled trial postoperative 3D-computed tomography (CT) and gait analysis before and 6 and 12 months after THA were obtained in 60 patients. Kinematic pelvic motion during gait was measured using Anybody Modeling System. By fusion with 3D-CT, the impact of kinematic pelvic tilt alterations on cup anteversion and inclination was calculated. Furthermore, risk factors correlating with high pelvic mobility were evaluated. During gait a high pelvic range of motion up to 15.6° exceeding 5° in 61.7% (37/60) of patients before THA was found. After surgery, the pelvis tilted posteriorly by a mean of 4.0 ± 6.6° (p < .001). The pelvic anteflexion led to a mean decrease of −1.9 ± 2.2° (p < .001) for cup inclination and −15.1 ± 6.1° (p < .001) for anteversion in relation to the anterior pelvic plane (APP). Kinematic pelvic changes resulted in a further change up to 2.3° for inclination and up to 12.3° for anteversion. In relation to the preoperative situation differences in postoperative cup position ranged from −4.4 to 4.6° for inclination and from −7.8 to 17.9° for anteversion, respectively. Female sex (p < .001) and normal body weight (p < .001) correlated with high alterations in pelvic tilt. Kinematic pelvic changes highly impact cup anteversion in THA. Surgeons using the APP as reference should aim for a higher anteversion of about 15° due to the functional anteflexion of the pelvis during gait. KW - component position KW - gait analysis KW - kinematics KW - pelvic tilt KW - total hip arthroplasty KW - Hüftgelenkprothese KW - Haltungsfehler KW - Hüftgelenkpfanne Y1 - 2021 U6 - https://doi.org/10.1002/jor.25106 SN - 1554-527X VL - 40 IS - 4 SP - 846 EP - 853 PB - Wiley ER - TY - JOUR A1 - Weber, Markus A1 - Merle, Christian A1 - Nawabi, Danyal H. A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Renkawitz, Tobias T1 - Inaccurate offset restoration in total hip arthroplasty results in reduced range of motion JF - Scientific Reports N2 - Offset restoration in total hip arthroplasty (THA) is associated with postoperative range of motion (ROM) and gait kinematics. We aimed to research into the impact of high offset (HO) and standard stems on postoperative ROM. 121 patients received cementless THA through a minimally-invasive anterolateral approach. A 360° hip ROM analysis software calculated impingement-free hip movement based on postoperative 3D-CTs compared to ROM values necessary for activities of daily living (ADL). The same model was then run a second time after changing the stem geometry between standard and HO configuration with the implants in the same position. HO stems showed higher ROM for all directions between 4.6 and 8.9° (p < 0.001) compared with standard stems but with high interindividual variability. In the subgroup with HO stems for intraoperative offset restoration, the increase in ROM was even higher for all ROM directions with values between 6.1 and 14.4° (p < 0.001) compared to offset underrestoration with standard stems. Avoiding offset underrestoration resulted in a higher amount of patients of over 20% for each ROM direction that fulfilled the criteria for ADL (p < 0.001). In contrast, in patients with standard stems for offset restoration ROM did increase but not clinically relevant by offset overcorrection for all directions between 3.1 and 6.1° (p < 0.001). Offset overcorrection by replacing standard with HO stems improved ROM for ADL in a low number of patients below 10% (p > 0.03). Patient-individual restoration of offset is crucial for free ROM in THA. Both over and underrestoration of offset should be avoided. KW - Adaptive clinical trial KW - Bone imaging Y1 - 2020 U6 - https://doi.org/10.1038/s41598-020-70059-1 VL - 10 IS - 13208 SP - 9 PB - Nature ER - TY - JOUR A1 - Melzner, Maximilian A1 - Suess, Franz A1 - Dendorfer, Sebastian T1 - The impact of anatomical uncertainties on the predictions of a musculoskeletal hand model – a sensitivity study JF - Computer Methods in Biomechanics and Biomedical Engineering N2 - Outputs of musculoskeletal models should be considered probabilistic rather than deterministic as they are affected by inaccuracies and estimations associated with the development of the model. One of these uncertainties being critical for modeling arises from the determination of the muscles' line of action and the physiological cross-sectional area. Therefore, the aim of this study was to evaluate the outcome sensitivity of model predictions from a musculoskeletal hand model in comparison to the uncertainty of these input parameters. For this purpose, the kinematics and muscle activities of different hand movements (abduction of the fingers, abduction of the thumb, and flexion of the thumb) were recorded. One thousand simulations were calculated for each movement using the Latin hypercube sampling method with a corresponding variation of the muscle origin/insertion points and the cross-sectional area. Comparing the standard hand to simulations incorporating uncertainties of input parameters shows no major deviations in on- and off-set time point of muscle activities. About 60% of simulations are located within a ± 30% interval around the standard model concerning joint reaction forces. The comparison with the variation of the input data leads to the conclusion that the standard hand model is able to provide not over-scattered outcomes and, therefore, can be considered relatively stable. These results are of practical importance to the personalization of a musculoskeletal model with subject-specific bone geometries and hence changed muscle line of action. KW - Biomechanik KW - Simulation Y1 - 2021 U6 - https://doi.org/10.1080/10255842.2021.1940974 SN - 1476-8259 N1 - Corresponding author: Maximilian Melzner VL - 25 IS - 2 SP - 156 EP - 164 PB - Taylor & Francis ER - TY - JOUR A1 - Dendorfer, Sebastian T1 - Älterwerden muss auch mal wehtun! JF - Gesunde Hochschule, OTH Regensburg, 4.7.2016 Y1 - 2016 ER - TY - JOUR A1 - Scheer, Clara A1 - Kubowitsch, Simone A1 - Dendorfer, Sebastian A1 - Jansen, Petra T1 - Happy Enough to Relax? How Positive and Negative Emotions Activate Different Muscular Regions in the Back - an Explorative Study JF - Frontiers in Psychology N2 - Embodiment theories have proposed a reciprocal relationship between emotional state and bodily reactions. Besides large body postures, recent studies have found emotions to affect rather subtle bodily expressions, such as slumped or upright sitting posture. This study investigated back muscle activity as an indication of an effect of positive and negative emotions on the sitting position. The electromyography (EMG) activity of six back muscles was recorded in 31 healthy subjects during exposure to positive and negative affective pictures. A resting period was used as a control condition. Increased muscle activity patterns in the back were found during the exposure to negative emotional stimuli, which was mainly measured in the lumbar and thorax regions. The positive emotion condition caused no elevated activity. The findings show that negative emotions lead to increased differential muscle activity in the back and thus corroborate those of previous research that emotion affects subtle bodily expressions. KW - electromyography KW - muscle activity KW - emotion KW - sadness KW - happiness KW - embodiment Y1 - 2021 U6 - https://doi.org/10.3389/fpsyg.2021.511746 SN - 1664-1078 VL - Volume 12 IS - May 2021 PB - Frontiers Media ER - TY - JOUR A1 - Melzner, Maximilian A1 - Engelhardt, Lucas A1 - Simon, Ulrich A1 - Dendorfer, Sebastian T1 - Electromyography-Based Validation of a Musculoskeletal Hand Model JF - Journal of Biomechanical Engineering N2 - Regarding the prevention of injuries and rehabilitation of the human hand, musculoskeletal simulations using an inverse dynamics approach allow for insights of the muscle recruitment and thus acting forces on the hand. Currently, several hand models from various research groups are in use, which are mainly validated by the comparison of numerical and anatomical moment arms. In contrast to this validation and model-building technique by cadaver studies, the aim of this study is to further validate a recently published hand model [1] by analyzing numerically calculated muscle activities in comparison to experimentally measured electromyographical signals of the muscles. Therefore, the electromyographical signals of 10 hand muscles of five test subjects performing seven different hand movements were measured. The kinematics of these tasks were used as input for the hand model, and the numerical muscle activities were computed. To analyze the relationship between simulated and measured activities, the time difference of the muscle on- and off-set points was calculated, which resulted in a mean on- and off-set time difference of 0.58 s between the experimental data and the model. The largest differences were detected for movements that mainly addressed the wrist. One major issue comparing simulated and measured muscle activities of the hand is cross-talk. Nevertheless, the results show that the hand model fits the experiment quite accurately despite some limitations and is a further step toward patient-specific modeling of the upper extremity. KW - Elektromyographie KW - Biomechanik KW - Simulation KW - Electromyography KW - Muscle KW - Musculoskeletal system KW - Signals KW - Simulation Y1 - 2021 U6 - https://doi.org/10.1115/1.4052115 VL - 144 IS - 2 PB - American Society of Mechanical Engineers, ASME ER - TY - JOUR A1 - Auer, Simon A1 - Kurbowitsch, Simone A1 - Süß, Franz A1 - Renkawitz, Tobias A1 - Krutsch, Werner A1 - Dendorfer, Sebastian T1 - Mental stress reduces performance and changes musculoskeletal loading in football-related movements JF - Science and Medicine in Football N2 - Purpose: Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Hence, this study investigated the musculoskeletal response of elite youth football players during highly dynamic movements under stress. The hypothesis is that mental stress reduces performance and changes the muscular forces exerted. Materials & methods: Twelve elite youth football players were subjected to mental stress while performing sports-specific change-of-direction movements. A modified version of the d2 attention test was used as stressor. The kinetics are computed using inverse dynamics. Running times and exerted forces of injury-prone muscles were analysed. Results: The stressor runs were rated more mentally demanding by the players (p = 0.006, rs = 0.37) with unchanged physical demand (p = 0.777, rs = 0.45). This resulted in 10% longer running times under stress (p < 0.001, d = −1.62). The musculoskeletal analysis revealed higher peak muscle forces under mental stress for some players but not for others. Discussion: The study shows that motion capture combined with musculoskeletal computation is suitable to analyse the effects of stress on athletes in highly dynamic movements. For the first time in football medicine, our data quantifies an association between mental stress with reduced football players’ performance and changes in muscle force. KW - Biomechanics KW - muscle injury KW - attention KW - musculoskeletal simulation Y1 - 2020 U6 - https://doi.org/10.1080/24733938.2020.1860253 VL - 5 IS - 4 SP - 323 EP - 329 PB - Taylor & Francis ER - TY - JOUR A1 - Engelhardt, Lucas A1 - Melzner, Maximilian A1 - Havelkova, Linda A1 - Fiala, Pavel A1 - Christen, Patrik A1 - Dendorfer, Sebastian A1 - Simon, Ulrich T1 - A new musculoskeletal AnyBodyTM detailed hand model JF - Computer Methods in Biomechanics and Biomedical Engineering N2 - Musculoskeletal research questions regarding the prevention or rehabilitation of the hand can be addressed using inverse dynamics simulations when experiments are not possible. To date, no complete human hand model implemented in a holistic human body model has been fully developed. The aim of this work was to develop, implement, and validate a fully detailed hand model using the AnyBody Modelling System (AMS) (AnyBody, Aalborg, Denmark). To achieve this, a consistent multiple cadaver dataset, including all extrinsic and intrinsic muscles, served as a basis. Various obstacle methods were implemented to obtain with the correct alignment of the muscle paths together with the full range of motion of the fingers. These included tori, cylinders, and spherical ellipsoids. The origin points of the lumbrical muscles within the tendon of the flexor digitorum profundus added a unique feature to the model. Furthermore, the possibility of an entire patient-specific scaling based on the hand length and width were implemented in the model. For model validation, experimental datasets from the literature were used, which included the comparison of numerically calculated moment arms of the wrist, thumb, and index finger muscles. In general, the results displayed good comparability of the model and experimental data. However, the extrinsic muscles showed higher accordance than the intrinsic ones. Nevertheless, the results showed, that the proposed developed inverse dynamics hand model offers opportunities in a broad field of applications, where the muscles and joint forces of the forearm play a crucial role. KW - Musculoskeletal KW - hand KW - AnyBody KW - inverse dynamics KW - moment arm Y1 - 2020 U6 - https://doi.org/10.1080/10255842.2020.1851367 VL - 24 IS - 7 SP - 777 EP - 787 PB - Taylor & Francis ER - TY - JOUR A1 - Saffert, Anne-Sophie A1 - Melzner, Maximilian A1 - Dendorfer, Sebastian T1 - Biomechanical analysis of the right elevated glenohumeral joint in violinists during legato-playing JF - Technology and Health Care N2 - BACKGROUND: Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements. OBJECTIVE: For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture. METHODS: Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position. RESULTS: The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture. CONCLUSIONS: Elevating the right shoulder while playing the violin may pose a potential problem. KW - Biomechanische Analyse KW - Schultergelenk KW - Verletzung KW - Violinspiel KW - biomechanics KW - violin KW - shoulder elevation KW - shoulder joint force KW - musculoskeletal disease Y1 - 2022 U6 - https://doi.org/10.3233/THC-219001 N1 - Corresponding author: Anne-Sophie Saffert VL - 30 IS - 1 SP - 177 EP - 186 PB - IOS Press ER - TY - JOUR A1 - Auer, Simon A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics JF - Technology and Health Care N2 - BACKGROUND: This study presents a comprehensive comparison between a marker-based motion capture system (MMC) and a video-based motion capture system (VMC) in the context of kinematic analysis using musculoskeletal models. OBJECTIVE: Focusing on joint angles, the study aimed to evaluate the accuracy of VMC as a viable alternative for biomechanical research. METHODS: Eighteen healthy subjects performed isolated movements with 17 joint degrees of freedom, and their kinematic data were collected using both an MMC and a VMC setup. The kinematic data were entered into the AnyBody Modelling System, which enables the calculation of joint angles. The mean absolute error (MAE) was calculated to quantify the deviations between the two systems. RESULTS: The results showed good agreement between VMC and MMC at several joint angles. In particular, the shoulder, hip and knee joints showed small deviations in kinematics with MAE values of 4.8∘, 6.8∘ and 3.5∘, respectively. However, the study revealed problems in tracking hand and elbow movements, resulting in higher MAE values of 13.7∘ and 27.7∘. Deviations were also higher for head and thoracic movements. CONCLUSION: Overall, VMC showed promising results for lower body and shoulder kinematics. However, the tracking of the wrist and pelvis still needs to be refined. The research results provide a basis for further investigations that promote the fusion of VMC and musculoskeletal models. KW - biomechanics KW - range of motion KW - musculoskeletal system KW - optical motion capture Y1 - 2024 U6 - https://doi.org/10.3233/THC-240202 SN - 0928-7329 N1 - Corresponding author der OTH Regensburg: Sebastian Dendorfer SP - 1 EP - 10 PB - IOS Press ER - TY - JOUR A1 - Philipp, Alois A1 - de Somer, Filip A1 - Foltan, Maik A1 - Bredthauer, Andre A1 - Krenkel, Lars A1 - Zeman, Florian A1 - Lehle, Karla T1 - Life span of different extracorporeal membrane systems for severe respiratory failure in the clinical practice JF - PLOS ONE N2 - Over the past decade, veno-venous extracorporeal membrane oxygenation (vvECMO) has been increasingly utilized in respiratory failure in patients. This study presents our institution´s experience focusing on the life span of ECMO systems reflecting the performance of a particular system. A retrospective review of our ECMO database identified 461 adult patients undergoing vvECMO (2010-2017). Patients that required more than one system and survived the first exchange >24 hours (n = 139) were included. Life span until the first exchange and exchange criteria were analyzed for all systems (PLS, Cardiohelp HLS-set, both Maquet Cardiopulmonary, Rastatt, Germany; Deltastream/Hilite7000LT, iLA-activve, Xenios/NovaLung, Heilbronn, Germany; ECC.O5, LivaNova, Mirandola, Italy). At our ECMO center, the frequency of a system exchange was 30%. The median (IQR) life span was 9 (6-12) days. There was no difference regarding the different systems (p = 0.145 and p = 0.108, respectively). However, the Deltastream systems were exchanged more frequently due to elective technical complications (e. g. worsened gas transfer, development of coagulation disorder, increased bleedings complications) compared to the other exchanged systems (p = 0.013). In summary, the used ECMO systems are safe and effective for acute respiratory failure. There is no evidence for the usage of a specific system. Only the increased predictability of an imminent exchange preferred the usage of a Deltastream system. However, the decision to use a particular system should not depend solely on the possible criteria for an exchange. KW - Equipment Failure Analysis/statistics & numerical data KW - Extracorporeal Membrane Oxygenation/instrumentation KW - Membrane/classification/standards/statistics & numerical data KW - Primary Health Care/statistics & numerical data KW - Respiratory Distress Syndrome/therapy KW - Retrospective Studies KW - Severity of Illness Index KW - Time factors KW - MULTIDETECTOR COMPUTED-TOMOGRAPHY KW - THROMBOTIC DEPOSITS KW - ECMO SYSTEMS KW - Flow KW - OXYGENATION Y1 - 2018 U6 - https://doi.org/10.1371/journal.pone.0198392 VL - 13 IS - 6 SP - 1 EP - 10 PB - PLOS ER - TY - JOUR A1 - Köck, Hannah A1 - Striegl, Birgit A1 - Kraus, Annalena A1 - Zborilova, Magdalena A1 - Christiansen, Silke H. A1 - Schäfer, Nicole A1 - Grässel, Susanne A1 - Hornberger, Helga T1 - In Vitro Analysis of Human Cartilage Infiltrated by Hydrogels and Hydrogel-Encapsulated Chondrocytes JF - Bioengineering N2 - Osteoarthritis (OA) is a degenerative joint disease causing loss of articular cartilage and structural damage in all joint tissues. Given the limited regenerative capacity of articular cartilage, methods to support the native structural properties of articular cartilage are highly anticipated. The aim of this study was to infiltrate zwitterionic monomer solutions into human OA-cartilage explants to replace lost proteoglycans. The study included polymerization and deposition of methacryloyloxyethyl-phosphorylcholine- and a novel sulfobetaine-methacrylate-based monomer solution within ex vivo human OA-cartilage explants and the encapsulation of isolated chondrocytes within hydrogels and the corresponding effects on chondrocyte viability. The results demonstrated that zwitterionic cartilage–hydrogel networks are formed by infiltration. In general, cytotoxic effects of the monomer solutions were observed, as was a time-dependent infiltration behavior into the tissue accompanied by increasing cell death and penetration depth. The successful deposition of zwitterionic hydrogels within OA cartilage identifies the infiltration method as a potential future therapeutic option for the repair/replacement of OA-cartilage extracellular suprastructure. Due to the toxic effects of the monomer solutions, the focus should be on sealing the OA-cartilage surface, instead of complete infiltration. An alternative treatment option for focal cartilage defects could be the usage of monomer solutions, especially the novel generated sulfobetaine-methacrylate-based monomer solution, as bionic for cell-based 3D bioprintable hydrogels. KW - osteoarthritis KW - human articular cartilage KW - chondrocytes KW - hydrogels KW - zwitterionic monomers KW - infiltration Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-61235 N1 - Corresponding author: Helga Hornberger VL - 10 SP - 1 EP - 21 PB - MDPI ER - TY - JOUR A1 - Hornberger, Helga A1 - Striegl, Birgit A1 - Trahanofsky, M. A1 - Kneissl, F. A1 - Kronseder, Matthias T1 - Degradation and bioactivity studies of Mg membranes for dental surgery JF - Materials Letter X N2 - Bioresorbable materials are under investigation due to their promising properties for applications as implant material. This study is about the degradation and bioactivity behaviour of magnesium foils, which allegorize dental membranes. The degradation behaviour including pitting corrosion during immersion tests can be precisely observed using micro-computed tomography. Using the bioactivity test according to Kokubo, it is shown that magnesium has strong Ca-phosphate layer formation correlated with high degradation. Therefore, magnesium foils appear to hold a great potential for bone implant application. KW - Magnesium KW - Dental membrane KW - Bioactivity KW - Corrosion rate Y1 - 2019 U6 - https://doi.org/10.1016/j.mlblux.2019.100007 VL - 2 IS - June SP - 1 EP - 5 PB - Elsevier ER - TY - JOUR A1 - Stelzer, Vera A1 - Krenkel, Lars T1 - 2D numerical investigations derived from a 3D dragonfly wing captured with a high-resolution micro-CT JF - Technology and health care : official journal of the European Society for Engineering and Medicine N2 - BACKGROUND: Due to their corrugated profile, dragonfly wings have special aerodynamic characteristics during flying and gliding. OBJECTIVE: The aim of this study was to create a realistic 3D model of a dragonfly wing captured with a high-resolution micro-CT. To represent geometry changes in span and chord length and their aerodynamic effects, numerical investigations are carried out at different wing positions. METHODS: The forewing of a Camacinia gigantea was captured using a micro-CT. After the wing was adapted an error-free 3D model resulted. The wing was cut every 5 mm and 2D numerical analyses were conducted in Fluent® 2020 R2 (ANSYS, Inc., Canonsburg, PA, USA). RESULTS: The highest lift coefficient, as well as the highest lift-to-drag ratio, resulted at 0 mm and an angle of attack (AOA) of 5∘. At AOAs of 10∘ or 15∘, the flow around the wing stalled and a Kármán vortex street behind the wing becomes CONCLUSIONS: The velocity is higher on the upper side of the wing compared to the lower side. The pressure acts vice versa. Due to the recirculation zones that are formed in valleys of the corrugation pattern the wing resembles the form of an airfoil. KW - aerodynamics KW - computational fluid dynamics KW - Dragonfly wing KW - gliding flight KW - insect flight Y1 - 2022 U6 - https://doi.org/10.3233/THC-219010 N1 - Corresponding author: Vera Stelzer VL - 30 IS - 1 SP - 283 EP - 289 PB - IOS Press ER - TY - JOUR A1 - Schecklmann, Martin A1 - Schmausser, Maximilian A1 - Klinger, Felix A1 - Kreuzer, Peter M. A1 - Krenkel, Lars A1 - Langguth, Berthold T1 - Resting motor threshold and magnetic field output of the figure-of-8 and the double-cone coil JF - scientific reports N2 - The use of the double-cone (DC) coil in transcranial magnetic stimulation (TMS) is promoted with the notion that the DC coil enables stimulation of deeper brain areas in contrast to conventional figure-of-8 (Fo8) coils. However, systematic comparisons of these two coil types with respect to the spatial distribution of the magnetic field output and also to the induced activity in superficial and deeper brain areas are limited. Resting motor thresholds of the left and right first dorsal interosseous (FDI) and tibialis anterior (TA) were determined with the DC and the Fo8 coil in 17 healthy subjects. Coils were orientated over the corresponding motor area in an angle of 45 degrees for the hand area with the handle pointing in posterior direction and in medio-lateral direction for the leg area. Physical measurements were done with an automatic gantry table using a Gaussmeter. Resting motor threshold was higher for the leg area in contrast to the hand area and for the Fo8 in contrast to the DC coil. Muscle by coil interaction was also significant providing higher differences between leg and hand area for the Fo8 (about 27%) in contrast to the DC coil (about 15%). Magnetic field strength was higher for the DC coil in contrast to the Fo8 coil. The DC coil produces a higher magnetic field with higher depth of penetration than the figure of eight coil. KW - ANTERIOR CINGULATE CORTEX KW - CONNECTIVITY KW - Depression KW - FRONTAL-CORTEX KW - PREDICTOR KW - RTMS KW - STIMULATION KW - TMS Y1 - 2020 U6 - https://doi.org/10.1038/s41598-020-58034-2 VL - 10 IS - 1 PB - Nature ER - TY - JOUR A1 - Raptis, Georgios T1 - Technischer Datenschutz in der telemedizinischen Versorgung JF - Der Krankenhaus-JUSTITIAR N2 - Die fortschreitende Digitalisierung des Gesundheitswesens ebnet auch den Weg einer stärkeren Verbreitung der telemedizinischen Versorgung in Deutschland. Die Politik erleichtert diesen Weg, z.B. mit dem eHealth-Gesetz oder mit der Lockerung des "Fernbehandlungsverbots" durch den Deutschen Ärztetag. Dabei wird schon aus der Definition (siehe z.B. die unten stehende Definition der AG Telemedizin) klar, dass Telemedizin keine neue medizinische Disziplin begründet. Bei Telemedizin handelt es sich nur um ein technisches Werkzeug in Kombination mit geeigneten klinischen Prozessen, damit bestehende medizinische Expertise unter Einsatz von Informations- und Kommunikationstechnologien räumliche Entfernungen oder einen zeitlichen Versatz überbrücken kann. Patientinnen und Patienten können also behandelt werden, auch wenn sie vom Arzt räumlich entfernt sind. KW - Telemedizin KW - Datenschutz Y1 - 2018 VL - 7 IS - 4 SP - 105 EP - 107 ER - TY - JOUR A1 - Raptis, Georgios T1 - Windows 10 und Datenschutz in der Arztpraxis JF - Bayerisches Ärzteblatt KW - Windows 10 KW - Datenschutz KW - Arztpraxis Y1 - 2016 UR - https://www.bayerisches-aerzteblatt.de/fileadmin/aerzteblatt/ausgaben/2016/07/komplettpdf/Baebl7_8_2016_Komplettausgabe.pdf IS - 7/8 SP - 364 ER - TY - JOUR A1 - Tauwald, Sandra Melina A1 - Michel, Johanna A1 - Brandt, Marie A1 - Vielsmeier, Veronika A1 - Stemmer, Christian A1 - Krenkel, Lars T1 - Experimental studies and mathematical modeling of the viscoelastic rheology of tracheobronchial mucus from respiratory healthy patients JF - Multidisciplinary Respiratory Medicine N2 - BACKGROUND: Tracheobronchial mucus plays a crucial role in pulmonary function by providing protection against inhaled pathogens. Due to its composition of water, mucins, and other biomolecules, it has a complex viscoelastic rheological behavior. This interplay of both viscous and elastic properties has not been fully described yet. In this study, we characterize the rheology of human mucus using oscillatory and transient tests. Based on the transient tests, we describe the material behavior of mucus under stress and strain loading by mathematical models. METHODS: Mucus samples were collected from clinically used endotracheal tubes. For rheological characterization, oscillatory amplitude-sweep and frequency-sweep tests, and transient creep-recovery and stress-relaxation tests were performed. The results of the transient test were approximated using the Burgers model, the Weibull distribution, and the six-element Maxwell model. The three-dimensional microstructure of the tracheobronchial mucus was visualized using scanning electron microscope imaging. RESULTS: Amplitude-sweep tests showed storage moduli ranging from 0.1 Pa to 10000 Pa and a median critical strain of 4 %. In frequency-sweep tests, storage and loss moduli increased with frequency, with the median of the storage modulus ranging from 10 Pa to 30 Pa, and the median of the loss modulus from 5 Pa to 14 Pa. The Burgers model approximates the viscoelastic behavior of tracheobronchial mucus during a constant load of stress appropriately (R2 of 0.99), and the Weibull distribution is suitable to predict the recovery of the sample after the removal of this stress (R2 of 0.99). The approximation of the stress-relaxation test data by a six-element Maxwell model shows a larger fit error (R2 of 0.91). CONCLUSIONS: This study provides a detailed description of all process steps of characterizing the rheology of tracheobronchial mucus, including sample collection, microstructure visualization, and rheological investigation. Based on this characterization, we provide mathematical models of the rheological behavior of tracheobronchial mucus. These can now be used to simulate mucus flow in the respiratory system through numerical approaches. KW - tracheobronchial mucus KW - rheological model KW - viscoelasticity Y1 - 2023 U6 - https://doi.org/10.4081/mrm.2023.923 SN - 2049-6958 N1 - Corresponding author: Sandra Melina Tauwald VL - 18 IS - 1 PB - PAGEPress CY - Pavia, Italy ER - TY - JOUR A1 - Birkenmaier, Clemens A1 - Dornia, Christian A1 - Lehle, Karla A1 - Müller, Thomas A1 - Gruber, Michael A1 - Philipp, Alois A1 - Krenkel, Lars T1 - Analysis of Thrombotic Deposits in Extracorporeal Membrane Oxygenators by High-resolution Microcomputed Tomography: A Feasibility Study JF - ASAIO Journal / American Society for Artificial Internal Organs N2 - Coagulative disorders, especially clotting during extracorporeal membrane oxygenation, are frequent complications. Direct visualization and analysis of deposits in membrane oxygenators using computed tomography (CT) may provide an insight into the underlying mechanisms causing thrombotic events. However, the already established multidetector CT1 (MDCT) method shows major limitations. Here, we demonstrate the feasibility of applying industrial micro-CT (μCT) to circumvent these restrictions. Three clinically used membrane oxygenators were investigated applying both MDCT and μCT. The scans were analyzed in terms of clot volume and local clot distribution. As validation, the clot volume was also determined from the fluid volume, which could be filled into the respective used oxygenator compared to a new device. In addition, cross-sectional CT images were compared with crosscut oxygenators. Based on the μCT findings, a morphological measure (sphericity) for assessing clot structures in membrane oxygenators is introduced. Furthermore, by comparing MDCT and μCT results, an augmentation of the MDCT method is proposed, which allows for improved clot volume determination in a clinical setting. Y1 - 2020 U6 - https://doi.org/10.1097/MAT.0000000000001089 SN - 1538-943X VL - 66 IS - 8 SP - 922 EP - 928 PB - Lippincott Williams & Wilkins ER - TY - JOUR A1 - Loo, Xuyan A1 - Nagaraju, Bhavana A1 - Pathivada, Sai A1 - Bartsch, Alexander A1 - Schratzenstaller, Thomas A1 - Sattler, Robert A1 - Monkman, Gareth J. T1 - Electrical properties of bisphenol-A-free magnetoactive borosilicate polymers JF - AIP Advances N2 - The recent REACH regulations require the elimination of bisphenol-A and titanium dioxide from commercially available boron-based polymers. This has led to changes in some of the mechanical characteristics, which strongly influence the properties of magnetoactive borosilicate polymers. This work delivers results on the electrical properties and discusses some implications for future research using bisphenol-A and titanium-dioxide-free substitutes. KW - Electrical components KW - Electrical properties and parameters KW - Dielectric properties KW - Electrical resistivity KW - Magnetic materials KW - Viscoelasticity KW - Polymers KW - Non Newtonian fluids KW - Magnetic fluids Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-72936 SN - 2158-3226 N1 - Corresponding author der OTH Regensburg: Gareth J. Monkman VL - 14 IS - 5 PB - AIP Publishing ER - TY - JOUR A1 - Eigenberger, Andreas A1 - Felthaus, Oliver A1 - Schratzenstaller, Thomas A1 - Haerteis, Silke A1 - Utpatel, Kirsten A1 - Prantl, Lukas T1 - The Effects of Shear Force-Based Processing of Lipoaspirates on White Adipose Tissue and the Differentiation Potential of Adipose Derived Stem Cells JF - cells N2 - Autologous lipotransfer is a promising method for tissue regeneration, because white adipose tissue contains a heterogeneous cell population, including mesenchymal stem cells, endothelial cells, immune cells, and adipocytes. In order to improve the outcome, adipose tissue can be processed before application. In this study, we investigated changes caused by mechanical processing. Lipoaspirates were processed using sedimentation, first-time centrifugation, shear-force homogenization, and second-time centrifugation. The average adipocyte size, stromal vascular cell count, and adipocyte depot size were examined histologically at every processing step. In addition, the adipose derived stem cells (ADSCs) were isolated and differentiated osteogenically and adipogenically. While homogenization causes a disruption of adipocyte depots, the shape of the remaining adipocytes is not changed. On average, these adipocytes are smaller than the depot adipocytes, they are surrounded by the ECM, and therefore mechanically more stable. The volume loss of adipocyte depots leads to a significant enrichment of stromal vascular cells such as ADSCs. However, the mechanical processing does not change the potential of the ADSCs to differentiate adipogenically or steogenically. It thus appears that mechanically processed lipoaspirates are promising for the reparation of even mechanically stressed tissue as that found in nasolabial folds. The changes resulting from the processing correspond more to a filtration of mechanically less stable components than to a manipulation of the tissue. KW - white adipose tissue KW - lipograft KW - stem cells KW - fat grafting KW - surgery KW - cell-enriched lipotransfer KW - CELT KW - lipoaspirate Y1 - 2022 U6 - https://doi.org/10.3390/cells11162543 VL - 11 IS - 16 PB - MDPI CY - Basel ER - TY - JOUR A1 - Obermaier, Lisa A1 - Lehle, Karla A1 - Schmid, Stefanie A1 - Schmid, Christof A1 - Schratzenstaller, Thomas T1 - Introduction of a new ex vivo porcine coronary artery model: Evaluation of the direct vascular injury after stent implantation with and without dogbone effect JF - European Surgical Research N2 - Introduction: Neointimal hyperplasia after percutaneous coronary intervention remains a major determinant of in-stent restenosis (ISR). The extent of mechanical vessel injury correlates with ISR. A new ex vivo porcine stent model was introduced and evaluated comparing different stent designs. Methods: Coronary arteries were prepared from pig hearts from the slaughterhouse and used for ex vivo implantations of coronary stents. One basic stent design in two configurations (dogbone, DB; non-dogbone, NDB) was used. Vascular injury was determined according to a modified injury score (IS). Results: Standardized experimental conditions ensured comparable vessel dimensions and overstretch data. DB stents caused more severe IS compared to NDB stents. The mean IS and the IS at the distal end of all stents were significantly reduced for NDB stents (ISMean, DB, 1.16 ±0.12; NDB, 1.02 ±0.12; p=0.018; ISDist, DB, 1.39 ±0.28; NDB, 1.13 ±0.24; p=0.03). Discussion/Conclusion: The introduced ex-vivo model allowed the evaluation of different stent designs exclude unfavorable stent designs. KW - Stent screening KW - Stent design KW - Injury score KW - Ex vivo porcine stent model Y1 - 2022 U6 - https://doi.org/10.1159/000527883 SN - 1421-9921 VL - 63 IS - 4 SP - 285 EP - 293 PB - Karger CY - Basel ER - TY - JOUR A1 - Geith, Markus A. A1 - Nothdurfter, Laurenz A1 - Heiml, Manuel A1 - Agrafiotis, Emmanouil A1 - Gruber, Markus A1 - Sommer, Gerhard A1 - Schratzenstaller, Thomas A1 - Holzapfel, Gerhard A. T1 - Quantifying stent-induced damage in coronary arteries by investigating mechanical and structural alterations JF - Acta Biomaterialia N2 - Vascular damage develops with diverging severity during and after percutaneous coronary intervention with stent placement and is the prevailing stimulus for in-stent restenosis. Previous work has failed to link mechanical data obtained in a realistic in vivo or in vitro environment with data collected during imaging processes. We investigated whether specimens of porcine right coronary arteries soften when indented with a stent strut shaped structure, and if the softening results from damage mechanisms inside the fibrillar collagen structure. To simulate the multiaxial loading scenario of a stented coronary artery, we developed the testing device ‘LAESIO’ that can measure differences in the stress-stretch behavior of the arterial wall before and after the indentation of a strut-like stamp. The testing protocol was optimized according to preliminary experiments, more specifically equilibrium and relaxation tests. After chemical fixation of the specimens and subsequent tissue clearing, we performed three-dimensional surface and second-harmonic generation scans on the deformed specimens. We analyzed and correlated the mechanical response with structural parameters of high-affected tissue located next to the stamp indentation and low-affected tissue beyond the injured area. The results reveal that damage mechanisms, like tissue compression as well as softening, fiber dispersion, and the lesion extent, are direction-dependent, and the severity of them is linked to the strut orientation, indentation pressure, and position. The findings highlight the need for further investigations by applying the proposed methods to human coronary arteries. Additional data and insights might help to incorporate the observed damage mechanisms into material models for finite element analyses to perform more accurate simulations of stent-implantations. KW - Percutaneous coronary intervention KW - Stent KW - Mechanical properties KW - Damage mechanism KW - Vascular injury KW - Coronary artery KW - Indentation test KW - Softening KW - Second-harmonic generation imaging KW - Micro-structure Y1 - 2020 U6 - https://doi.org/10.1016/j.actbio.2020.08.016 VL - 116 IS - October SP - 285 EP - 301 PB - Elsevier ER - TY - JOUR A1 - Wiesent, Lisa A1 - Schultheiss, Ulrich A1 - Schmid, Christof A1 - Schratzenstaller, Thomas A1 - Nonn, Aida T1 - Experimentally validated simulation of coronary stents considering different dogboning ratios and asymmetric stent positioning JF - PlOS One N2 - In-stent restenosis remains a major problem of arteriosclerosis treatment by stenting. Expansion-optimized stents could reduce this problem. With numerical simulations, stent designs/ expansion behaviours can be effectively analyzed. For reasons of efficiency, simplified models of balloon-expandable stents are often used, but their accuracy must be challenged due to insufficient experimental validation. In this work, a realistic stent life-cycle simulation has been performed including balloon folding, stent crimping and free expansion of the balloon-stent-system. The successful simulation and validation of two stent designs with homogenous and heterogeneous stent stiffness and an asymmetrically positioned stent on the balloon catheter confirm the universal applicability of the simulation approach. Dogboning ratio, as well as the final dimensions of the folded balloon, the crimped and expanded stent, correspond well to the experimental dimensions with only slight deviations. In contrast to the detailed stent life-cycle simulation, a displacement-controlled simulation can not predict the transient stent expansion, but is suitable to reproduce the final expanded stent shape and the associated stress states. The detailed stent life-cycle simulation is thus essential for stent expansion analysis/optimization, whereas for reasons of computational efficiency, the displacement-controlled approach can be considered in the context of pure stress analysis. KW - Catheters KW - Coronary stenting KW - Deformation KW - Stent implantation KW - Stiffness KW - Stent KW - Ballondilatation KW - Numerische Strömungssimulation Y1 - 2019 U6 - https://doi.org/10.1371/journal.pone.0224026 VL - 14 IS - 10 SP - 1 EP - 25 PB - PLOS ER -