TY - JOUR A1 - Weber, Karsten A1 - Dendorfer, Sebastian A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Schratzenstaller, Thomas A1 - Haug, Sonja A1 - Mohr, Christa A1 - Kiesl, Hans A1 - Drechsler, Jörg A1 - Westner, Markus A1 - Kobus, Jörn A1 - Schubert, Martin J. W. A1 - Zenger, Stefan A1 - Pietsch, Alexander A1 - Weiß, Josef A1 - Hinterseer, Sebastian A1 - Schieck, Roland A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Ringlstetter, Andreas A1 - Störl, Uta A1 - Bissyandé, Tegawendé F. A1 - Seeburger, Achim A1 - Schindler, Timo A1 - Ramsauer, Ralf A1 - Kiszka, Jan A1 - Kölbl, Andreas A1 - Lohmann, Daniel A1 - Mauerer, Wolfgang A1 - Maier, Johannes A1 - Scorna, Ulrike A1 - Palm, Christoph A1 - Soska, Alexander A1 - Mottok, Jürgen A1 - Ellermeier, Andreas A1 - Vögele, Daniel A1 - Hierl, Stefan A1 - Briem, Ulrich A1 - Buschmann, Knut A1 - Ehrlich, Ingo A1 - Pongratz, Christian A1 - Pielmeier, Benjamin A1 - Tyroller, Quirin A1 - Monkman, Gareth J. A1 - Gut, Franz A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian A1 - Langer, Christoph A1 - Schreiner, Rupert A1 - Huang, Yifeng A1 - She, Juncong A1 - Ottl, Andreas A1 - Rieger, Walter A1 - Kraml, Agnes A1 - Poxleitner, Thomas A1 - Hofer, Simon A1 - Heisterkamp, Benjamin A1 - Lerch, Maximilian A1 - Sammer, Nike A1 - Golde, Olivia A1 - Wellnitz, Felix A1 - Schmid, Sandra A1 - Muntschick, Claudia A1 - Kusterle, Wolfgang A1 - Paric, Ivan A1 - Brückl, Oliver A1 - Haslbeck, Matthias A1 - Schmidt, Ottfried A1 - Schwanzer, Peter A1 - Rabl, Hans-Peter A1 - Sterner, Michael A1 - Bauer, Franz A1 - Steinmann, Sven A1 - Eckert, Fabian A1 - Hofrichter, Andreas ED - Baier, Wolfgang T1 - Forschungsbericht 2017 T3 - Forschungsberichte der OTH Regensburg - 2017 KW - Forschung KW - Forschungsbericht Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13835 SN - 978-3-9818209-3-5 CY - Regensburg ER - TY - JOUR A1 - Swoboda, Walter A1 - Schmieder, Martin A1 - Bulitta, Clemens A1 - Gaisser, Sibylle A1 - Hofmann, Georg Rainer A1 - Kremer-Rücker, Prisca A1 - Krumme, Julia A1 - Kullmann, Walter A1 - Kunhardt, Horst A1 - Lauer, Norina A1 - Meussling-Sentpali, Annette A1 - Mohr, Christa A1 - Pfingsten, Andrea A1 - Riener, Andreas A1 - Terborg, Barbara A1 - Weber, Beatrix A1 - Weber, Karsten A1 - Wolff, Mechthild T1 - Die gemeinsame Ethik-Kommission der Hochschulen Bayerns - GEHBa JF - mdi - Forum der Medizin-Dokumentation und Medizin-Informatik N2 - Die Einholung eines Ethikvotums ist in der Medizin verpflichtend. Auch in anderen Disziplinen ist eine ethische Beurteilung häufig notwendig. Bisher gibt es nur wenig hierfür zuständige Stellen. Die gemeinsame Ethik-Kommission der Hochschulen Bayerns (GEHBa) füllt diese Lücke. Anträge können gestellt werden unter www.gehba.de. Y1 - 2021 SN - 1438-0900 VL - 23 IS - 3 SP - 80 EP - 83 PB - mdi GbR ER - TY - CHAP A1 - Herdl, Florian A1 - Bachmann, Michael A1 - Wohlfartsstätter, Dominik A1 - Düsberg, Felix A1 - Dudeck, Markus A1 - Eder, Magdalena A1 - Meyer, Manuel A1 - Pahlke, Andreas A1 - Edler, Simon A1 - Schels, Andreas A1 - Hansch, Walter A1 - Schreiner, Rupert A1 - Wohlfartsstatter, Dominik A1 - Dusberg, Felix T1 - A novel current dependent field emission performance test T2 - 2021 34th International Vacuum Nanoelectronics Conference (IVNC): 5-9 July 2021, Lyon, France N2 - A current dependent performance test for comparison of different field emitter arrays is introduced. Statistical analysis is enabled due to a short measurement time and as a main feature the electric field shift, comparable to the degradation of the emitter is examined. Significance of the test method is shown by a comparison of field emitter arrays with different doping levels. KW - Current measurement KW - Field emitter arrays KW - Statistical analysis KW - Systematics KW - Time measurement KW - Tools KW - Vacuum systems Y1 - 2021 U6 - https://doi.org/10.1109/IVNC52431.2021.9600695 SP - 1 EP - 2 ER - TY - JOUR A1 - Schels, Andreas A1 - Edler, Simon A1 - Herdl, Florian A1 - Hansch, Walter A1 - Bachmann, Michael A1 - Ritter, Daniela A1 - Dudeck, Markus A1 - Duesberg, Felix A1 - Meyer, Manuel A1 - Pahlke, Andreas A1 - Hausladen, Matthias A1 - Buchner, Philipp A1 - Schreiner, Rupert T1 - In situ quantitative field emission imaging using a low-cost CMOS imaging sensor JF - Journal of Vacuum Science & Technology B N2 - Spatially resolved field emission measurements represent an important factor in further development of existing field emitter concepts. In this work, we present a novel approach that allows quantitative analysis of individual emission spots from integral current-voltage measurements using a low-cost and commercially available CMOS camera. By combining different exposure times to extrapolate oversaturated and underexposed pixels, a near congruence of integral current and image brightness is shown. The extrapolation also allows parallel investigation of all individual tips participating in the total current with currents ranging from a few nanoampere to one microampere per tip. The sensitivity, which is determined by the integral brightness-to-current ratio, remains unchanged within the measurement accuracy even after ten full measurement cycles. Using a point detection algorithm, the proportional current load of each individual tip of the field emitter array is analyzed and compared at different times during the initial measurement cycle. Together with the extracted I-V curves of single emission spots from the integral measurement, the results indicate the effect of premature burnout of particularly sharp tips during conditioning of the emitter. KW - ARRAYS KW - ELECTRON-EMISSION KW - EMITTERS KW - FakANK Y1 - 2022 U6 - https://doi.org/10.1116/6.0001551 VL - 40 IS - 1 PB - AIP Publishing ER - TY - JOUR A1 - Edler, Simon A1 - Schels, Andreas A1 - Herdl, Florian A1 - Hansch, Walter A1 - Bachmann, Michael A1 - Dudeck, Markus A1 - Duesberg, Felix A1 - Pahlke, Andreas A1 - Hausladen, Matthias A1 - Buchner Philipp, A1 - Schreiner, Rupert T1 - Origin of the current saturation level of p-doped silicon field emitters JF - Journal of Vacuum Science & Technology B N2 - Using p-type semiconductors for field emitters is one simple way to realize an integrated current limiter to improve the lifetime of the cathode. In this work, the origin of the current saturation of p-type silicon emitters is investigated in detail. Single emitters are electrically characterized and compared to simulation results. With a simulation model considering a high surface generation rate and elevated tip temperature, a good agreement to the measured data is found. This observation is supported further by alteration of the surface experimentally. Electrical measurements after different treatments in hydrofluoric acid as well as heated and subsequent operation at room temperature are well explained by the influence of surface generation. Furthermore, it is shown that the field penetration leads to a small voltage drop and a strong geometry-dependent reduction of the field enhancement factor. KW - EMISSION KW - GROWTH KW - NATIVE-OXIDE Y1 - 2022 U6 - https://doi.org/10.1116/6.0001554 VL - 40 IS - 1 PB - AIP Publishing ER - TY - CHAP A1 - Schels, Andreas A1 - Herdl, Florian A1 - Hausladen, Matthias A1 - Wohlfartsstätter, Dominik A1 - Bachmann, Michael A1 - Edler, Simon A1 - Düsberg, Felix A1 - Pahlke, Andreas A1 - Buchner, Philipp A1 - Schreiner, Rupert A1 - Hansch, Walter T1 - Beta Factor Mapping of Individual Emitting Tips During Integral Operation of Field Emission Arrays T2 - 2023 IEEE 36th International Vacuum Nanoelectronics Conference (IVNC), 10-13 July 2023, Cambridge, MA, USA N2 - Emission uniformity mappings of field emitter arrays provide important insight into degradation mechanisms, but are often laborious, non-integral, costly, or not quantifiable. Here, a low-cost Raspberry Pi HQ camera is used as an extraction anode to quantify the emission distribution in field emitter arrays. A verification measurement using controlled SEM electron beams proves, that current-voltage characteristics of individual emission sites can be determined by combining the integral electrical data with the image data. The characteristics are used to quantify the field enhancement factors of an 30x30 silicon field emitter array during integral operation. Comparison of the field enhancement factor distributions before and after a one-hour constant current operation at 1 µA shows an increase from 50 actively emitting tips before to 156 after the measurement. It is shown, that the distribution of field enhancement factors shifts towards lower values, due to the increasing degradation for high field enhancement tips, especially above 1500. KW - field emission KW - field emission imaging KW - field emission distribution KW - field enhancement factor KW - CMOS imaging KW - beta factor Y1 - 2023 SN - 979-8-3503-0143-4 U6 - https://doi.org/10.1109/IVNC57695.2023.10188957 SP - 224 EP - 226 PB - IEEE ER - TY - JOUR A1 - Schels, Andreas A1 - Herdl, Florian A1 - Hausladen, Matthias A1 - Wohlfartsstätter, Dominik A1 - Edler, Simon A1 - Bachmann, Michael A1 - Pahlke, Andreas A1 - Schreiner, Rupert A1 - Hansch, Walter T1 - Quantitative Field Emission Imaging for Studying the Doping-Dependent Emission Behavior of Silicon Field Emitter Arrays JF - Micromachines N2 - Field emitter arrays (FEAs) are a promising component for novel vacuum micro- and nanoelectronic devices, such as microwave power amplifiers or fast-switching X-ray sources. However, the interrelated mechanisms responsible for FEA degradation and failure are not fully understood. Therefore, we present a measurement method for quantitative observation of individual emission sites during integral operation using a low-cost, commercially available CMOS imaging sensor. The emission and degradation behavior of three differently doped FEAs is investigated in current-regulated operation. The measurements reveal that the limited current of the p-doped emitters leads to an activation of up to 55% of the individual tips in the array, while the activation of the n-type FEA stopped at around 30%. This enhanced activation results in a more continuous and uniform current distribution for the p-type FEA. An analysis of the individual emitter characteristics before and after a constant current measurement provides novel perspectives on degradation behavior. A burn-in process that trims the emitting tips to an integral current-specific ideal field enhancement factor is observed. In this process, blunt tips are sharpened while sharp tips are dulled, resulting in homogenization within the FEA. The methodology is described in detail, making it easily adaptable for other groups to apply in the further development of promising FEAs. Y1 - 2023 U6 - https://doi.org/10.3390/mi14112008 VL - 14 IS - 11 PB - MDPI ER - TY - RPRT A1 - Ottl, Andreas A1 - Rieger, Walter T1 - Reinigung der Laderäume von Binnenschiffe nach Düngemitteltransporten Y1 - 2018 UR - https://www.bestellen.bayern.de/application/eshop_app000002?SID=1280764195&ACTIONxSESSxSHOWPIC(BILDxKEY:%27stmuv_abfall_004%27,BILDxCLASS:%27Artikel%27,BILDxTYPE:%27PDF%27) ER - TY - JOUR A1 - Barz, Tilman A1 - Seliger, Dominik A1 - Marx, Klemens A1 - Sommer, Andreas A1 - Walter, Sebastian F. A1 - Bock, Hans Georg A1 - Koerkel, Stefan T1 - State and state of charge estimation for a latent heat storage JF - Control Engineering Practice N2 - A nonlinear state observer is designed for a thermal energy storage with solid/liquid phase change material (PCM). Using a physical 2D dynamic model, the observer reconstructs transient spatial temperature fields inside the storage and estimates the stored energy and the state of charge. The observer has been successfully tested with a lab-scale latent heat storage with a single pass tube bundle and the phase change material located in a shell around each tube. It turns out that the observer robustly tracks the real process data with as few as four internal PCM temperature sensors. © 2017 Elsevier Ltd. All rights reserved. KW - Heat conduction in cylindrical shell KW - Kalman filter KW - Latent heat thermal energy storage (LHTES) KW - MODEL KW - Nonlinear state observer KW - OF-THE-ART KW - Orthogonal collocation KW - PCM KW - PERFORMANCE ENHANCEMENT TECHNIQUES KW - PHASE-CHANGE MATERIAL KW - POLYETHYLENE KW - Reduced model KW - simulation KW - Solidification KW - State of charge (SOC) KW - SYSTEMS KW - THERMAL-ENERGY STORAGE Y1 - 2018 U6 - https://doi.org/10.1016/j.conengprac.2017.11.006 VL - 72 SP - 151 EP - 166 PB - Pergamon-Elsevier d. ER - TY - CHAP A1 - Schels, Andreas A1 - Edler, Simon A1 - Hansch, Walter A1 - Bachmann, Michael A1 - Herdl, F. A1 - Dusberg, F. A1 - Eder, Magdalena A1 - Meyer, M. A1 - Dudek, M. A1 - Pahlke, A. A1 - Schreiner, Rupert ED - Purcell, Stephen ED - Mazellier, Jean-Paul T1 - Current dependent performance test used on different types of silicon field emitter arrays T2 - 2021 34th International Vacuum Nanoelectronics Conference (IVNC): 5-9 July 2021, Lyon, France N2 - A current dependent performance test is used to investigate the influence of doping and emitter geometry on the lifetime of silicon field emitter arrays. The measurements reveal an improved performance for lower n-type dopant concentrations. Furthermore, two new types of field emitters are introduced by slightly varying the original fabrication process [1]. The comparison shows superiority of tip like emitters over blade like structures. Y1 - 2021 SN - 978-1-6654-2589-6 U6 - https://doi.org/10.1109/IVNC52431.2021.9600787 SP - 1 EP - 2 PB - IEEE CY - Piscataway, NJ ER -