TY - JOUR A1 - Mauerer, Wolfgang A1 - Rexhepaj, Tanja A1 - Monkman, Gareth J. A1 - Sindersberger, Dirk A1 - Diermeier, Andreas A1 - Neidhart, Thomas A1 - Wolfrum, Dominik A1 - Sterner, Michael A1 - Heberl, Michael A1 - Nusko, Robert A1 - Maier, Georg A1 - Nagl, Klaus A1 - Reuter, Monika A1 - Hofrichter, Andreas A1 - Lex, Thomas A1 - Lesch, Florian A1 - Kieninger, Bärbel A1 - Szalo, Alexander Eduard A1 - Zehner, Alexander A1 - Palm, Christoph A1 - Joblin, Mitchell A1 - Apel, Sven A1 - Ramsauer, Ralf A1 - Lohmann, Daniel A1 - Westner, Markus A1 - Strasser, Artur A1 - Munndi, Maximilian A1 - Ebner, Lena A1 - Elsner, Michael A1 - Weiß, Nils A1 - Segerer, Matthias A1 - Hackenberg, Rudolf A1 - Steger, Sebastian A1 - Schmailzl, Anton A1 - Dostalek, Michael A1 - Armbruster, Dominik A1 - Koch, Fabian A1 - Hierl, Stefan A1 - Thumann, Philipp A1 - Swidergal, Krzysztof A1 - Wagner, Marcus A1 - Briem, Ulrich A1 - Diermeier, Andreas A1 - Spreitzer, Stefan A1 - Beiderbeck, Sabrina A1 - Hook, Christian A1 - Zobel, Martin A1 - Weber, Tim A1 - Groß, Simon A1 - Penzkofer, Rainer A1 - Dendorfer, Sebastian A1 - Schillitz, Ingo A1 - Bauer, Thomas A1 - Rudolph, Clarissa A1 - Schmidt, Katja A1 - Liebetruth, Thomas A1 - Hamer, Markus A1 - Haug, Sonja A1 - Vernim, Matthias A1 - Weber, Karsten A1 - Saßmannshausen, Sean Patrick A1 - Books, Sebastian A1 - Neuleitner, Nikolaus A1 - Rechenauer, Christian A1 - Steffens, Oliver A1 - Kusterle, Wolfgang A1 - Gömmel, Roland A1 - Wellnitz, Felix A1 - Stierstorfer, Johannes A1 - Stadler, Dominik A1 - Hofmann, Matthias J. A1 - Motschmann, Hubert A1 - Shamonin (Chamonine), Mikhail A1 - Bleicher, Veronika A1 - Fischer, Sebastian A1 - Hackenberg, Rudolf A1 - Horn, Anton A1 - Kawasch, Raphael A1 - Petzenhauser, Michael A1 - Probst, Tobias A1 - Udalzow, Anton A1 - Dams, Florian A1 - Schreiner, Rupert A1 - Langer, Christoph A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian ED - Baier, Wolfgang T1 - Forschungsbericht 2016 T3 - Forschungsberichte der OTH Regensburg - 2016 Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13840 CY - Regensburg ER - TY - JOUR A1 - Ebigbo, Alanna A1 - Mendel, Robert A1 - Scheppach, Markus W. A1 - Probst, Andreas A1 - Shahidi, Neal A1 - Prinz, Friederike A1 - Fleischmann, Carola A1 - Römmele, Christoph A1 - Gölder, Stefan Karl A1 - Braun, Georg A1 - Rauber, David A1 - Rückert, Tobias A1 - Souza Jr., Luis Antonio de A1 - Papa, João Paulo A1 - Byrne, Michael F. A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Vessel and tissue recognition during third-space endoscopy using a deep learning algorithm JF - Gut N2 - In this study, we aimed to develop an artificial intelligence clinical decision support solution to mitigate operator-dependent limitations during complex endoscopic procedures such as endoscopic submucosal dissection and peroral endoscopic myotomy, for example, bleeding and perforation. A DeepLabv3-based model was trained to delineate vessels, tissue structures and instruments on endoscopic still images from such procedures. The mean cross-validated Intersection over Union and Dice Score were 63% and 76%, respectively. Applied to standardised video clips from third-space endoscopic procedures, the algorithm showed a mean vessel detection rate of 85% with a false-positive rate of 0.75/min. These performance statistics suggest a potential clinical benefit for procedure safety, time and also training. KW - Artificial Intelligence KW - Endoscopy KW - Medical Image Computing Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-54293 VL - 71 IS - 12 SP - 2388 EP - 2390 PB - BMJ CY - London ER - TY - JOUR A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Palm, Christoph A1 - Probst, Andreas A1 - Muzalyova, Anna A1 - Scheppach, Markus W. A1 - Nagl, Sandra A1 - Schnoy, Elisabeth A1 - Römmele, Christoph A1 - Schulz, Dominik Andreas Helmut Otto A1 - Schlottmann, Jakob A1 - Prinz, Friederike A1 - Rauber, David A1 - Rückert, Tobias A1 - Matsumura, Tomoaki A1 - Fernández-Esparrach, Glòria A1 - Parsa, Nasim A1 - Byrne, Michael F. A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Influence of artificial intelligence on the diagnostic performance of endoscopists in the assessment of Barrett’s esophagus: a tandem randomized and video trial JF - Endoscopy N2 - Background This study evaluated the effect of an artificial intelligence (AI)-based clinical decision support system on the performance and diagnostic confidence of endoscopists in their assessment of Barrett’s esophagus (BE). Methods 96 standardized endoscopy videos were assessed by 22 endoscopists with varying degrees of BE experience from 12 centers. Assessment was randomized into two video sets: group A (review first without AI and second with AI) and group B (review first with AI and second without AI). Endoscopists were required to evaluate each video for the presence of Barrett’s esophagus-related neoplasia (BERN) and then decide on a spot for a targeted biopsy. After the second assessment, they were allowed to change their clinical decision and confidence level. Results AI had a stand-alone sensitivity, specificity, and accuracy of 92.2%, 68.9%, and 81.3%, respectively. Without AI, BE experts had an overall sensitivity, specificity, and accuracy of 83.3%, 58.1%, and 71.5%, respectively. With AI, BE nonexperts showed a significant improvement in sensitivity and specificity when videos were assessed a second time with AI (sensitivity 69.8% [95%CI 65.2%–74.2%] to 78.0% [95%CI 74.0%–82.0%]; specificity 67.3% [95%CI 62.5%–72.2%] to 72.7% [95%CI 68.2%–77.3%]). In addition, the diagnostic confidence of BE nonexperts improved significantly with AI. Conclusion BE nonexperts benefitted significantly from additional AI. BE experts and nonexperts remained significantly below the stand-alone performance of AI, suggesting that there may be other factors influencing endoscopists’ decisions to follow or discard AI advice. KW - Artificial Intelligence KW - Endoscopy KW - Medical Image Computing Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-72818 VL - 56 SP - 641 EP - 649 PB - Georg Thieme Verlag CY - Stuttgart ER - TY - GEN A1 - Zellmer, Stephan A1 - Rauber, David A1 - Probst, Andreas A1 - Weber, Tobias A1 - Braun, Georg A1 - Römmele, Christoph A1 - Nagl, Sandra A1 - Schnoy, Elisabeth A1 - Messmann, Helmut A1 - Ebigbo, Alanna A1 - Palm, Christoph T1 - Artificial intelligence as a tool in the detection of the papillary ostium during ERCP T2 - Endoscopy N2 - Aims Endoscopic retrograde cholangiopancreaticography (ERCP) is the gold standard in the diagnosis as well as treatment of diseases of the pancreatobiliary tract. However, it is technically complex and has a relatively high complication rate. In particular, cannulation of the papillary ostium remains challenging. The aim of this study is to examine whether a deep-learning algorithm can be used to detect the major duodenal papilla and in particular the papillary ostium reliably and could therefore be a valuable tool for inexperienced endoscopists, particularly in training situation. Methods We analyzed a total of 654 retrospectively collected images of 85 patients. Both the major duodenal papilla and the ostium were then segmented. Afterwards, a neural network was trained using a deep-learning algorithm. A 5-fold cross-validation was performed. Subsequently, we ran the algorithm on 5 prospectively collected videos of ERCPs. Results 5-fold cross-validation on the 654 labeled data resulted in an F1 value of 0.8007, a sensitivity of 0.8409 and a specificity of 0.9757 for the class papilla, and an F1 value of 0.5724, a sensitivity of 0.5456 and a specificity of 0.9966 for the class ostium. Regardless of the class, the average F1 value (class papilla and class ostium) was 0.6866, the sensitivity 0.6933 and the specificity 0.9861. In 100% of cases the AI-detected localization of the papillary ostium in the prospectively collected videos corresponded to the localization of the cannulation performed by the endoscopist. Conclusions In the present study, the neural network was able to identify the major duodenal papilla with a high sensitivity and high specificity. In detecting the papillary ostium, the sensitivity was notably lower. However, when used on videos, the AI was able to identify the location of the subsequent cannulation with 100% accuracy. In the future, the neural network will be trained with more data. Thus, a suitable tool for ERCP could be established, especially in the training situation. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1783138 VL - 56 IS - S 02 SP - S198 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Roser, David A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Palm, Christoph A1 - Probst, Andreas A1 - Muzalyova, Anna A1 - Scheppach, Markus W. A1 - Nagl, Sandra A1 - Schnoy, Elisabeth A1 - Römmele, Christoph A1 - Schulz, Dominik Andreas Helmut Otto A1 - Schlottmann, Jakob A1 - Prinz, Friederike A1 - Rauber, David A1 - Rückert, Tobias A1 - Matsumura, Tomoaki A1 - Fernandez-Esparrach, G. A1 - Parsa, Nasim A1 - Byrne, Michael F. A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Human-Computer Interaction: Impact of Artificial Intelligence on the diagnostic confidence of endoscopists assessing videos of Barrett’s esophagus T2 - Endoscopy N2 - Aims Human-computer interactions (HCI) may have a relevant impact on the performance of Artificial Intelligence (AI). Studies show that although endoscopists assessing Barrett’s esophagus (BE) with AI improve their performance significantly, they do not achieve the level of the stand-alone performance of AI. One aspect of HCI is the impact of AI on the degree of certainty and confidence displayed by the endoscopist. Indirectly, diagnostic confidence when using AI may be linked to trust and acceptance of AI. In a BE video study, we aimed to understand the impact of AI on the diagnostic confidence of endoscopists and the possible correlation with diagnostic performance. Methods 22 endoscopists from 12 centers with varying levels of BE experience reviewed ninety-six standardized endoscopy videos. Endoscopists were categorized into experts and non-experts and randomly assigned to assess the videos with and without AI. Participants were randomized in two arms: Arm A assessed videos first without AI and then with AI, while Arm B assessed videos in the opposite order. Evaluators were tasked with identifying BE-related neoplasia and rating their confidence with and without AI on a scale from 0 to 9. Results The utilization of AI in Arm A (without AI first, with AI second) significantly elevated confidence levels for experts and non-experts (7.1 to 8.0 and 6.1 to 6.6, respectively). Only non-experts benefitted from AI with a significant increase in accuracy (68.6% to 75.5%). Interestingly, while the confidence levels of experts without AI were higher than those of non-experts with AI, there was no significant difference in accuracy between these two groups (71.3% vs. 75.5%). In Arm B (with AI first, without AI second), experts and non-experts experienced a significant reduction in confidence (7.6 to 7.1 and 6.4 to 6.2, respectively), while maintaining consistent accuracy levels (71.8% to 71.8% and 67.5% to 67.1%, respectively). Conclusions AI significantly enhanced confidence levels for both expert and non-expert endoscopists. Endoscopists felt significantly more uncertain in their assessments without AI. Furthermore, experts with or without AI consistently displayed higher confidence levels than non-experts with AI, irrespective of comparable outcomes. These findings underscore the possible role of AI in improving diagnostic confidence during endoscopic assessment. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1782859 SN - 1438-8812 VL - 56 IS - S 02 SP - 79 PB - Georg Thieme Verlag ER - TY - GEN A1 - Zellmer, Stephan A1 - Rauber, David A1 - Probst, Andreas A1 - Weber, Tobias A1 - Braun, Georg A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Schnoy, Elisabeth A1 - Birzle, Lisa A1 - Aehling, Niklas A1 - Schulz, Dominik Andreas Helmut Otto A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Künstliche Intelligenz als Hilfsmittel zur Detektion der Papilla duodeni major und des papillären Ostiums während der ERCP T2 - Zeitschrift für Gastroenterologie N2 - Einleitung  Die Endoskopische Retrograde Cholangiopankreatikographie (ERCP) ist der Goldstandard in der endoskopischen Therapie von Erkrankungen des pankreatobiliären Trakts. Allerdings ist sie technisch anspruchsvoll, schwer zu erlernen und mit einer relativ hohen Komplikationsrate assoziiert. Daher soll in der vorliegenden Machbarkeitsstudie geprüft werden, ob mithilfe eines Deeplearning- Algorithmus die Papille und das Ostium zuverlässig detektiert werden können und dieser für Endoskopiker, insbesondere in der Ausbildungssituation, ein geeignetes Hilfsmittel darstellen könnte. Material und Methodik Insgesamt wurden 1534 ERCP-Bilder von 134 Patienten analysiert, wobei sowohl die Papilla duodeni major als auch das Ostium segmentiert wurden. Anschließend erfolgte das Training eines neuronalen Netzes unter Verwendung eines Deep-Learning-Algorithmus. Für den Test des Algorithmus erfolgte eine fünffache Kreuzvalidierung. Ergebnisse  Auf den 1534 gelabelten Bildern wurden für die Klasse Papille ein F1-Wert von 0,7996, eine Sensitivität von 0,8488 und eine Spezifität von 0,9822 erzielt. Für die Klasse Ostium ergaben sich ein F1-Wert von 0,5198, eine Sensitivität von 0,5945 und eine Spezifität von 0,9974. Klassenübergreifend (Klasse Papille und Klasse Ostium) betrug der F1-Wert 0,6593, die Sensitivität 0,7216 und für die Spezifität 0,9898. Zusammenfassung  In der vorliegenden Machbarkeitsstudie zeigte das neuronale Netz eine hohe Sensitivität und eine sehr hohe Spezifität bei der Identifikation der Papilla duodeni major. Die Detektion des Ostiums erfolgte hingegen mit einer deutlich geringeren Sensitivität. Zukünftig ist eine Erweiterung des Trainingsdatensatzes um Videos und klinische Daten vorgesehen, um die Leistungsfähigkeit des Netzwerks zu verbessern. Hierdurch könnte langfristig ein geeignetes Assistenzsystem für die ERCP, insbesondere in der Ausbildungssituation etabliert werden. Y1 - 2025 U6 - https://doi.org/10.1055/s-0045-1806882 VL - 63 IS - 5 SP - e295 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Ebigbo, Alanna A1 - Mendel, Robert A1 - Rückert, Tobias A1 - Schuster, Laurin A1 - Probst, Andreas A1 - Manzeneder, Johannes A1 - Prinz, Friederike A1 - Mende, Matthias A1 - Steinbrück, Ingo A1 - Faiss, Siegbert A1 - Rauber, David A1 - Souza Jr., Luis Antonio de A1 - Papa, João Paulo A1 - Deprez, Pierre A1 - Oyama, Tsuneo A1 - Takahashi, Akiko A1 - Seewald, Stefan A1 - Sharma, Prateek A1 - Byrne, Michael F. A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Endoscopic prediction of submucosal invasion in Barrett’s cancer with the use of Artificial Intelligence: A pilot Study JF - Endoscopy N2 - Background and aims: The accurate differentiation between T1a and T1b Barrett’s cancer has both therapeutic and prognostic implications but is challenging even for experienced physicians. We trained an Artificial Intelligence (AI) system on the basis of deep artificial neural networks (deep learning) to differentiate between T1a and T1b Barrett’s cancer white-light images. Methods: Endoscopic images from three tertiary care centres in Germany were collected retrospectively. A deep learning system was trained and tested using the principles of cross-validation. A total of 230 white-light endoscopic images (108 T1a and 122 T1b) was evaluated with the AI-system. For comparison, the images were also classified by experts specialized in endoscopic diagnosis and treatment of Barrett’s cancer. Results: The sensitivity, specificity, F1 and accuracy of the AI-system in the differentiation between T1a and T1b cancer lesions was 0.77, 0.64, 0.73 and 0.71, respectively. There was no statistically significant difference between the performance of the AI-system and that of human experts with sensitivity, specificity, F1 and accuracy of 0.63, 0.78, 0.67 and 0.70 respectively. Conclusion: This pilot study demonstrates the first multicenter application of an AI-based system in the prediction of submucosal invasion in endoscopic images of Barrett’s cancer. AI scored equal to international experts in the field, but more work is necessary to improve the system and apply it to video sequences and in a real-life setting. Nevertheless, the correct prediction of submucosal invasion in Barret´s cancer remains challenging for both experts and AI. KW - Maschinelles Lernen KW - Neuronales Netz KW - Speiseröhrenkrebs KW - Diagnose KW - Artificial Intelligence KW - Machine learning KW - Adenocarcinoma KW - Barrett’s cancer KW - submucosal invasion Y1 - 2021 U6 - https://doi.org/10.1055/a-1311-8570 VL - 53 IS - 09 SP - 878 EP - 883 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Probst, Andreas A1 - Rauber, David A1 - Rückert, Tobias A1 - Meinikheim, Michael A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Real-time detection and delineation of tissue during third-space endoscopy using artificial intelligence (AI) T2 - Endoscopy N2 - Aims  AI has proven great potential in assisting endoscopists in diagnostics, however its role in therapeutic endoscopy remains unclear. Endoscopic submucosal dissection (ESD) is a technically demanding intervention with a slow learning curve and relevant risks like bleeding and perforation. Therefore, we aimed to develop an algorithm for the real-time detection and delineation of relevant structures during third-space endoscopy. Methods  5470 still images from 59 full length videos (47 ESD, 12 POEM) were annotated. 179681 additional unlabeled images were added to the training dataset. Consequently, a DeepLabv3+ neural network architecture was trained with the ECMT semi-supervised algorithm (under review elsewhere). Evaluation of vessel detection was performed on a dataset of 101 standardized video clips from 15 separate third-space endoscopy videos with 200 predefined blood vessels. Results  Internal validation yielded an overall mean Dice score of 85% (68% for blood vessels, 86% for submucosal layer, 88% for muscle layer). On the video test data, the overall vessel detection rate (VDR) was 94% (96% for ESD, 74% for POEM). The median overall vessel detection time (VDT) was 0.32 sec (0.3 sec for ESD, 0.62 sec for POEM). Conclusions  Evaluation of the developed algorithm on a video test dataset showed high VDR and quick VDT, especially for ESD. Further research will focus on a possible clinical benefit of the AI application for VDR and VDT during third-space endoscopy. KW - Speiseröhrenkrankheit KW - Künstliche Intelligenz KW - Artificial Intelligence Y1 - 2023 U6 - https://doi.org/10.1055/s-0043-1765128 VL - 55 IS - S02 SP - S53 EP - S54 PB - Thieme ER - TY - GEN A1 - Zellmer, Stephan A1 - Rauber, David A1 - Probst, Andreas A1 - Weber, Tobias A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Schnoy, Elisabeth A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Verwendung künstlicher Intelligenz bei der Detektion der Papilla duodeni major T2 - Zeitschrift für Gastroenterologie N2 - Einleitung Die Endoskopische Retrograde Cholangiopankreatikographie (ERCP) ist der Goldstandard in der Diagnostik und Therapie von Erkrankungen des pankreatobiliären Trakts. Jedoch ist sie technisch sehr anspruchsvoll und weist eine vergleichsweise hohe Komplikationsrate auf. Ziele  In der vorliegenden Machbarkeitsstudie soll geprüft werden, ob mithilfe eines Deep-learning-Algorithmus die Papille und das Ostium zuverlässig detektiert werden können und somit für Endoskopiker mit geringer Erfahrung ein geeignetes Hilfsmittel, insbesondere für die Ausbildungssituation, darstellen könnten. Methodik Wir betrachteten insgesamt 606 Bilddatensätze von 65 Patienten. In diesen wurde sowohl die Papilla duodeni major als auch das Ostium segmentiert. Anschließend wurde eine neuronales Netz mittels eines Deep-learning-Algorithmus trainiert. Außerdem erfolgte eine 5-fache Kreuzvaldierung. Ergebnisse Bei einer 5-fachen Kreuzvaldierung auf den 606 gelabelten Daten konnte für die Klasse Papille eine F1-Wert von 0,7908, eine Sensitivität von 0,7943 und eine Spezifität von 0,9785 erreicht werden, für die Klasse Ostium eine F1-Wert von 0,5538, eine Sensitivität von 0,5094 und eine Spezifität von 0,9970 (vgl. [Tab. 1]). Unabhängig von der Klasse zeigte sich gemittelt (Klasse Papille und Klasse Ostium) ein F1-Wert von 0,6673, eine Sensitivität von 0,6519 und eine Spezifität von 0,9877 (vgl. [Tab. 2]). Schlussfolgerung  In vorliegende Machbarkeitsstudie konnte das neuronale Netz die Papilla duodeni major mit einer hohen Sensitivität und sehr hohen Spezifität identifizieren. Bei der Detektion des Ostiums war die Sensitivität deutlich geringer. Zukünftig soll das das neuronale Netz mit mehr Daten trainiert werden. Außerdem ist geplant, den Algorithmus auch auf Videos anzuwenden. Somit könnte langfristig ein geeignetes Hilfsmittel für die ERCP etabliert werden. KW - Künstliche Intelligenz Y1 - 2023 UR - https://www.thieme-connect.de/products/ejournals/abstract/10.1055/s-0043-1772000 U6 - https://doi.org/10.1055/s-0043-1772000 VL - 61 IS - 08 SP - e539 EP - e540 PB - Thieme CY - Stuttgart ER - TY - CHAP A1 - Hammer, Pascal A1 - Mottok, Jürgen A1 - Krause, Veronika A1 - Probst, Tobias T1 - Approach for High-Performance Random Number Generators for Critical Systems T2 - Proceeding of the 12th European Congress on Embedded Real Time Software and Systems (ERTS2024) , Toulouse, 11-12 June 2024 N2 - In times of digitalization, the encryption and signing of sensitive data is becoming increasingly important. These cryptographic processes require large quantities of high-quality random numbers. Which is why a high-performance random number generator (RNG) is to be developed. For this purpose, existing concepts of RNGs and application standards are first analyzed. The proposed approach is to design a physical true random number generator (PTRNG) with a high output of random numbers. Based on this, the development begins with the analog part of the RNG, the noise signal source and a suitable amplifier for the analog noise signal. Therefore, a special noise diode from Noisecom and an amplifier from NXP were chosen and analyzed in different measurements. From the results of the measurements, it can be concluded that both components are suitable for use in the RNG. Y1 - 2024 U6 - https://doi.org/10.5281/zenodo.14848832 N1 - Identifier: hal-04678880 , version 1 ER -