TY - JOUR A1 - Renkawitz, Tobias A1 - Weber, Tim A. A1 - Dullien, Silvia A1 - Woerner, Michael A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Weber, Markus T1 - Leg length and offset differences above 5 mm after total hip arthroplasty are associated with altered gait kinematics JF - Gait & Posture N2 - We aimed to investigate the relationship between postoperative leg length/offset (LL/OS) reconstruction and gait performance after total hip arthroplasty (THA). In the course of a prospective randomized controlled trial, 60 patients with unilateral hip arthrosis received cementless THA through a minimally-invasive anterolateral surgical approach. One year post-operatively, LL and global OS restoration were analyzed and compared to the contralateral hip on AP pelvic radiographs. The combined postoperative limb length/OS reconstruction of the operated hip was categorized as restored (within 5 mm) or non-restored (more than 5 mm reduction or more than 5 mm increment). The acetabular component inclination, anteversion and femoral component anteversion were evaluated using CT scans of the pelvis and the femur. 3D gait analysis of the lower extremity and patient related outcome measures (HHS, HOOS, EQ-5D) were obtained pre-operatively, six months and twelve months post-operatively by an observer blinded to radiographic results. Component position of cup and stem was comparable between the restored and non-restored group. Combined LL and OS restoration within 5 mm resulted in higher Froude number (p < 0.001), normalized walking speed (p < 0.001) and hip range-of-motion (ROM) (p = 0.004) during gait twelve months postoperatively, whereas gait symmetry was comparable regardless of LL and OS reconstruction at both examinations. Clinical scores did not show any relevant association between the accuracy of LL or OS reconstruction and gait six/twelve months after THA. In summary, postoperative LL/OS discrepancies larger than 5 mm relate to unphysiological gait kinematics within the first year after THA. DRKS00000739, German Clinical Trials Register. KW - THA KW - Leg length KW - Offset KW - Gait analysis KW - Biomechanics Y1 - 2016 U6 - https://doi.org/10.1016/j.gaitpost.2016.07.011 VL - vol. 49 SP - 196 EP - 201 ER - TY - JOUR A1 - Renkawitz, Tobias A1 - Weber, Markus A1 - Springorum, H.-R. A1 - Sendtner, E. A1 - Woerner, Michael A1 - Ulm, K. A1 - Weber, Tim A1 - Grifka, Joachim T1 - Impingement-free range of motion, cup coverage and early clinical results between femur first navigation and conventional total hip arthroplasty: a randomised controlled trial JF - Journal of Bone & Joint Surgery N2 - We report the kinematic and early clinical results of a patient- and observer-blinded randomised controlled trial in which CT scans were used to compare potential impingement-free range of movement (ROM) and acetabular component cover between patients treated with either the navigated 'femur-first' total hip arthroplasty (THA) method (n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75). The Hip Osteoarthritis Outcome Score, the Harris hip score, the Euro-Qol-5D and the Mancuso THA patient expectations score were assessed at six weeks, six months and one year after surgery. A total of 48 of the patients (84%) in the navigated 'femur-first' group and 43 (65%) in the conventional group reached all the desirable potential ROM boundaries without prosthetic impingement for activities of daily living (ADL) in flexion, extension, abduction, adduction and rotation (p = 0.016). Acetabular component cover and surface contact with the host bone were > 87% in both groups. There was a significant difference between the navigated and the conventional groups' Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated 'femur-first' technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups. KW - combined anteversion KW - computer-assisted orthopaedic surgery KW - THA KW - Hüftgelenkprothese KW - Operationstechnik KW - Computerunterstütztes Verfahren KW - Beweglichkeit Y1 - 2015 U6 - https://doi.org/10.1302/0301-620X.97B7.34729 VL - 97-B SP - 890 EP - 898 ER - TY - JOUR A1 - Weber, Markus A1 - Weber, Tim A. A1 - Woerner, Michael A1 - Craiovan, Benjamin A1 - Worlicek, Michael A1 - Winkler, Sebastian A1 - Grifka, Joachim A1 - Renkawitz, Tobias T1 - The impact of standard combined anteversion definitions on gait and clinical outcome within one year after total hip arthroplasty JF - International Orthopaedics N2 - Different target areas within the concept of combined cup and stem anteversion have been published for total hip arthroplasty (THA). We asked whether component positioning according to eight standard combined anteversion rules is associated with (1) more physiological gait patterns, (2) higher improvement of gait variables and (3) better clinical outcome after THA.In a prospective clinical study, 60 patients received cementless THA through an anterolateral MIS approach in a lateral decubitus position. Six weeks postoperatively, implant position was analysed using 3D-CT by an independent external institute. Preoperatively, six and 12 months postoperatively range of motion, normalized walking speed and hip flexion symmetry index were measured using 3D motion-capture gait analysis. Patient-related outcome measures (HHS, HOOS, EQ-5D) were obtained by an observer blinded to 3D-CT results. Eight combined anteversion definitions and Lewinnek's "safe zone" were evaluated regarding their impact on gait patterns and clinical outcome.Combined cup and stem anteversion according to standard combined anteversion definitions as well as cup placement within Lewinnek's "safe zone" did not influence range of motion, normalized walking speed and/or hip flexion symmetry index six and 12 months after THA. Similarly, increase of gait parameters within the first year after THA was comparable between all eight combined anteversion rules. Clinical outcome measures like HHS, HOOS and EQ-5D did not show any benefit for either of the combined anteversion definitions.Standard combined cup and stem anteversion rules do not improve postoperative outcome as measured by gait analysis and clinical scores within one year after THA. KW - Total hip athroplasty KW - Combined anteversion KW - Outcome KW - Gait analysis KW - Hüftgelenkprothese KW - Bewegungsanalyse KW - Gehen KW - Funktionelle Anatomie Y1 - 2015 U6 - https://doi.org/10.1007/s00264-015-2777-8 VL - 39 IS - 12 SP - 2323 EP - 2333 ER - TY - CHAP A1 - Weber, Tim A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Weber, Markus A1 - Wörner, Michael A1 - Dullien, Silvia A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias T1 - Verbessert die computerassistierte Femur First Operationstechnik für die Hüftendoprothetik den muskuloskelettalen Lastfall auf das Hüftgelenk? T2 - DKOU 2015, Deutscher Kongress für Orthopädie und Unfallchirurgie 2015 Y1 - 2015 UR - https://www.researchgate.net/publication/283259007_Verbessert_die_computerassistierte_Femur_First_Operationstechnik_fur_die_Huftendoprothetik_den_muskuloskelettalen_Lastfall_auf_das_Huftgelenk ER - TY - JOUR A1 - Völlner, Florian A1 - Weber, Tim A. A1 - Weber, Markus A1 - Renkawitz, Tobias A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Craiovan, Benjamin T1 - A simple method for determining ligament stiffness during total knee arthroplasty in vivo JF - Scientific Reports N2 - A key requirement in both native knee joints and total knee arthroplasty is a stable capsular ligament complex. However, knee stability is highly individual and ranges from clinically loose to tight. So far, hardly any in vivo data on the intrinsic mechanical of the knee are available. This study investigated if stiffness of the native ligament complex may be determined in vivo using a standard knee balancer. Measurements were obtained with a commercially available knee balancer, which was initially calibrated in vitro. 5 patients underwent reconstruction of the force-displacement curves of the ligament complex. Stiffness of the medial and lateral compartments were calculated to measure the stability of the capsular ligament complex. All force-displacement curves consisted of a non-linear section at the beginning and of a linear section from about 80 N onwards. The medial compartment showed values of 28.4 ± 1.2 N/mm for minimum stiffness and of 39.9 ± 1.1 N/mm for maximum stiffness; the respective values for the lateral compartment were 19.9 ± 0.9 N/mm and 46.6 ± 0.8 N/mm. A commercially available knee balancer may be calibrated for measuring stiffness of knee ligament complex in vivo, which may contribute to a better understanding of the intrinsic mechanical behaviour of knee joints. KW - Biomechanische Analyse KW - Kniegelenkband KW - Steifigkeit Y1 - 2019 U6 - https://doi.org/10.1038/s41598-019-41732-x VL - 9 SP - 1 EP - 8 PB - Nature ER -