TY - JOUR A1 - Scharfenberg, Georg A1 - Mottok, Jürgen A1 - Artmann, Christina A1 - Hobelsberger, Martin A1 - Paric, Ivan A1 - Großmann, Benjamin A1 - Pohlt, Clemens A1 - Wackerbarth, Alena A1 - Pausch, Uli A1 - Heidrich, Christiane A1 - Fadanelli, Martin A1 - Elsner, Michael A1 - Pöcher, Daniel A1 - Pittroff, Lenz A1 - Beer, Stefan A1 - Brückl, Oliver A1 - Haslbeck, Matthias A1 - Sterner, Michael A1 - Thema, Martin A1 - Muggenthaler, Nicole A1 - Lenck, Thorsten A1 - Götz, Philipp A1 - Eckert, Fabian A1 - Deubzer, Michael A1 - Stingl, Armin A1 - Simsek, Erol A1 - Krämer, Stefan A1 - Großmann, Benjamin A1 - Schlegl, Thomas A1 - Niedersteiner, Sascha A1 - Berlehner, Thomas A1 - Joblin, Mitchell A1 - Mauerer, Wolfgang A1 - Apel, Sven A1 - Siegmund, Janet A1 - Riehle, Dirk A1 - Weber, Joachim A1 - Palm, Christoph A1 - Zobel, Martin A1 - Al-Falouji, Ghassan A1 - Prestel, Dietmar A1 - Scharfenberg, Georg A1 - Mandl, Roland A1 - Deinzer, Arnulf A1 - Halang, W. A1 - Margraf-Stiksrud, Jutta A1 - Sick, Bernhard A1 - Deinzer, Renate A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Störl, Uta A1 - Wiech, Katharina A1 - Kubata, Christoph A1 - Sindersberger, Dirk A1 - Monkman, Gareth J. A1 - Dollinger, Markus A1 - Dembianny, Sven A1 - Kölbl, Andreas A1 - Welker, Franz A1 - Meier, Matthias A1 - Thumann, Philipp A1 - Swidergal, Krzysztof A1 - Wagner, Marcus A1 - Haug, Sonja A1 - Vernim, Matthias A1 - Seidenstücker, Barbara A1 - Weber, Karsten A1 - Arsan, Christian A1 - Schone, Reinhold A1 - Münder, Johannes A1 - Schroll-Decker, Irmgard A1 - Dillinger, Andrea Elisabeth A1 - Fuchshofer, Rudolf A1 - Monkman, Gareth J. A1 - Shamonin (Chamonine), Mikhail A1 - Geith, Markus A. A1 - Koch, Fabian A1 - Ühlin, Christian A1 - Schratzenstaller, Thomas A1 - Saßmannshausen, Sean Patrick A1 - Auchter, Eberhard A1 - Kriz, Willy A1 - Springer, Othmar A1 - Thumann, Maria A1 - Kusterle, Wolfgang A1 - Obermeier, Andreas A1 - Udalzow, Anton A1 - Schmailzl, Anton A1 - Hierl, Stefan A1 - Langer, Christoph A1 - Schreiner, Rupert ED - Baier, Wolfgang T1 - Forschungsbericht 2015 T3 - Forschungsberichte der OTH Regensburg - 2015 Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13867 SN - 978-3-00-048589-3 CY - Regensburg ER - TY - JOUR A1 - Weber, Karsten A1 - Dendorfer, Sebastian A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Schratzenstaller, Thomas A1 - Haug, Sonja A1 - Mohr, Christa A1 - Kiesl, Hans A1 - Drechsler, Jörg A1 - Westner, Markus A1 - Kobus, Jörn A1 - Schubert, Martin J. W. A1 - Zenger, Stefan A1 - Pietsch, Alexander A1 - Weiß, Josef A1 - Hinterseer, Sebastian A1 - Schieck, Roland A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Ringlstetter, Andreas A1 - Störl, Uta A1 - Bissyandé, Tegawendé F. A1 - Seeburger, Achim A1 - Schindler, Timo A1 - Ramsauer, Ralf A1 - Kiszka, Jan A1 - Kölbl, Andreas A1 - Lohmann, Daniel A1 - Mauerer, Wolfgang A1 - Maier, Johannes A1 - Scorna, Ulrike A1 - Palm, Christoph A1 - Soska, Alexander A1 - Mottok, Jürgen A1 - Ellermeier, Andreas A1 - Vögele, Daniel A1 - Hierl, Stefan A1 - Briem, Ulrich A1 - Buschmann, Knut A1 - Ehrlich, Ingo A1 - Pongratz, Christian A1 - Pielmeier, Benjamin A1 - Tyroller, Quirin A1 - Monkman, Gareth J. A1 - Gut, Franz A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian A1 - Langer, Christoph A1 - Schreiner, Rupert A1 - Huang, Yifeng A1 - She, Juncong A1 - Ottl, Andreas A1 - Rieger, Walter A1 - Kraml, Agnes A1 - Poxleitner, Thomas A1 - Hofer, Simon A1 - Heisterkamp, Benjamin A1 - Lerch, Maximilian A1 - Sammer, Nike A1 - Golde, Olivia A1 - Wellnitz, Felix A1 - Schmid, Sandra A1 - Muntschick, Claudia A1 - Kusterle, Wolfgang A1 - Paric, Ivan A1 - Brückl, Oliver A1 - Haslbeck, Matthias A1 - Schmidt, Ottfried A1 - Schwanzer, Peter A1 - Rabl, Hans-Peter A1 - Sterner, Michael A1 - Bauer, Franz A1 - Steinmann, Sven A1 - Eckert, Fabian A1 - Hofrichter, Andreas ED - Baier, Wolfgang T1 - Forschungsbericht 2017 T3 - Forschungsberichte der OTH Regensburg - 2017 KW - Forschung KW - Forschungsbericht Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13835 SN - 978-3-9818209-3-5 CY - Regensburg ER - TY - JOUR A1 - Kheiroddin, Parastoo A1 - Schöberl, Patricia A1 - Althammer, Michael A1 - Cibali, Ezgi A1 - Würfel, Thea A1 - Wein, Hannah A1 - Kulawik, Birgit A1 - Buntrock-Döpke, Heike A1 - Weigl, Eva A1 - Gran, Silvia A1 - Gründl, Magdalena A1 - Langguth, Jana A1 - Lampl, Benedikt A1 - Judex, Guido A1 - Niggel, Jakob A1 - Pagel, Philipp A1 - Schratzenstaller, Thomas A1 - Schneider-Brachert, Wulf A1 - Gastiger, Susanne A1 - Bodenschatz, Mona A1 - Konrad, Maike A1 - Levchuk, Artem A1 - Roth, Cornelius A1 - Schöner, David A1 - Schneebauer, Florian A1 - Rohrmanstorfer, René A1 - Burkovski, Andreas A1 - Ambrosch, Andreas A1 - Wagner, Thomas A1 - Kabesch, Michael ED - Buonsenso, Danilo T1 - Results of WICOVIR Gargle Pool PCR Testing in German Schools Based on the First 100,000 Tests JF - Frontiers in Pediatrics N2 - Background: Opening schools and keeping children safe from SARS-CoV-2 infections at the same time is urgently needed to protect children from direct and indirect consequences of the COVID-19 pandemic. To achieve this goal, a safe, efficient, and cost-effective SARS-CoV-2 testing system for schools in addition to standard hygiene measures is necessary. Methods: We implemented the screening WICOVIR concept for schools in the southeast of Germany, which is based on gargling at home, pooling of samples in schools, and assessment of SARS-CoV-2 by pool rRT-PCR, performed decentralized in numerous participating laboratories. Depooling was performed if pools were positive, and results were transmitted with software specifically developed for the project within a day. Here, we report the results after the first 13 weeks in the project. Findings: We developed and implemented the proof-of-concept test system within a pilot phase of 7 weeks based on almost 17,000 participants. After 6 weeks in the main phase of the project, we performed >100,000 tests in total, analyzed in 7,896 pools, identifying 19 cases in >100 participating schools. On average, positive children showed an individual CT value of 31 when identified in the pools. Up to 30 samples were pooled (mean 13) in general, based on school classes and attached school staff. All three participating laboratories detected positive samples reliably with their previously established rRT-PCR standard protocols. When self-administered antigen tests were performed concomitantly in positive cases, only one of these eight tests was positive, and when antigen tests performed after positive pool rRT-PCR results were already known were included, 3 out of 11 truly positive tests were also identified by antigen testing. After 3 weeks of repetitive WICOVIR testing twice weekly, the detection rate of positive children in that cohort decreased significantly from 0.042 to 0.012 (p = 0.008). Interpretation: Repeated gargle pool rRT-PCR testing can be implemented quickly in schools. It is an effective, valid, and well-received test system for schools, superior to antigen tests in sensitivity, acceptance, and costs. KW - children KW - COVID-19 KW - Germany KW - PCR KW - pooling KW - gargle KW - schools KW - pandemic KW - Covid-19 KW - Polymerase-Kettenreaktion KW - Nachweis KW - Schulkind KW - Deutschland Y1 - 2021 U6 - https://doi.org/10.3389/fped.2021.721518 SN - 2296-2360 VL - 9 PB - frontiers ER - TY - JOUR A1 - Schaeffer, Leon A1 - Herrmann, David A1 - Schratzenstaller, Thomas A1 - Dendorfer, Sebastian A1 - Böhm, Valter T1 - Preliminary theoretical considerations on the stiffness characteristics of a tensegrity joint for the use in dynamic orthoses JF - Journal of Medical Robotics Research N2 - Early motion therapy plays an important role for effective long-term healing of joint injuries. In many cases, conventional dynamic orthoses fail to address the intricate movement possibilities of the underlying joints, limited by their simplistic joint representations, often represented by revolute joints, enabling rotations by only one axis. In this paper, a two-dimensional compliant tensegrity joint for use in biomedical applications is investigated. It consists of two compressed members and five compliant tensioned members. Relative movement possibilities are realized by the intrinsic compliance of the structure. In the development of these systems, the first step is the determination of the static stable equilibrium. This analysis is conducted in this paper by considering the potential energy approach or by using the geometric nonlinear finite element method. The mechanical behavior of the structure is assessed with a specific emphasis on its mechanical compliance. The primary objective of this study is the investigation of the influence of structural parameters on the overall stiffness and movability of the structure. The results underscore the significant effect of member parameters on the stiffness and movability of the compliant tensegrity joint, particularly under varying load magnitudes. These findings provide insights for optimizing the joint’s performance, contributing to its potential application in advanced orthotic and exoskeleton devices. KW - mechanical compliance KW - flexibility ellipsis KW - form-finding KW - tensegrity joint Y1 - 2023 U6 - https://doi.org/10.1142/S2424905X23400081 PB - World Scientific ER - TY - JOUR A1 - Loo, Xuyan A1 - Nagaraju, Bhavana A1 - Pathivada, Sai A1 - Bartsch, Alexander A1 - Schratzenstaller, Thomas A1 - Sattler, Robert A1 - Monkman, Gareth J. T1 - Electrical properties of bisphenol-A-free magnetoactive borosilicate polymers JF - AIP Advances N2 - The recent REACH regulations require the elimination of bisphenol-A and titanium dioxide from commercially available boron-based polymers. This has led to changes in some of the mechanical characteristics, which strongly influence the properties of magnetoactive borosilicate polymers. This work delivers results on the electrical properties and discusses some implications for future research using bisphenol-A and titanium-dioxide-free substitutes. KW - Electrical components KW - Electrical properties and parameters KW - Dielectric properties KW - Electrical resistivity KW - Magnetic materials KW - Viscoelasticity KW - Polymers KW - Non Newtonian fluids KW - Magnetic fluids Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-72936 SN - 2158-3226 N1 - Corresponding author der OTH Regensburg: Gareth J. Monkman VL - 14 IS - 5 PB - AIP Publishing ER - TY - JOUR A1 - Eigenberger, Andreas A1 - Felthaus, Oliver A1 - Schratzenstaller, Thomas A1 - Haerteis, Silke A1 - Utpatel, Kirsten A1 - Prantl, Lukas T1 - The Effects of Shear Force-Based Processing of Lipoaspirates on White Adipose Tissue and the Differentiation Potential of Adipose Derived Stem Cells JF - cells N2 - Autologous lipotransfer is a promising method for tissue regeneration, because white adipose tissue contains a heterogeneous cell population, including mesenchymal stem cells, endothelial cells, immune cells, and adipocytes. In order to improve the outcome, adipose tissue can be processed before application. In this study, we investigated changes caused by mechanical processing. Lipoaspirates were processed using sedimentation, first-time centrifugation, shear-force homogenization, and second-time centrifugation. The average adipocyte size, stromal vascular cell count, and adipocyte depot size were examined histologically at every processing step. In addition, the adipose derived stem cells (ADSCs) were isolated and differentiated osteogenically and adipogenically. While homogenization causes a disruption of adipocyte depots, the shape of the remaining adipocytes is not changed. On average, these adipocytes are smaller than the depot adipocytes, they are surrounded by the ECM, and therefore mechanically more stable. The volume loss of adipocyte depots leads to a significant enrichment of stromal vascular cells such as ADSCs. However, the mechanical processing does not change the potential of the ADSCs to differentiate adipogenically or steogenically. It thus appears that mechanically processed lipoaspirates are promising for the reparation of even mechanically stressed tissue as that found in nasolabial folds. The changes resulting from the processing correspond more to a filtration of mechanically less stable components than to a manipulation of the tissue. KW - white adipose tissue KW - lipograft KW - stem cells KW - fat grafting KW - surgery KW - cell-enriched lipotransfer KW - CELT KW - lipoaspirate Y1 - 2022 U6 - https://doi.org/10.3390/cells11162543 VL - 11 IS - 16 PB - MDPI CY - Basel ER - TY - JOUR A1 - Obermaier, Lisa A1 - Lehle, Karla A1 - Schmid, Stefanie A1 - Schmid, Christof A1 - Schratzenstaller, Thomas T1 - Introduction of a new ex vivo porcine coronary artery model: Evaluation of the direct vascular injury after stent implantation with and without dogbone effect JF - European Surgical Research N2 - Introduction: Neointimal hyperplasia after percutaneous coronary intervention remains a major determinant of in-stent restenosis (ISR). The extent of mechanical vessel injury correlates with ISR. A new ex vivo porcine stent model was introduced and evaluated comparing different stent designs. Methods: Coronary arteries were prepared from pig hearts from the slaughterhouse and used for ex vivo implantations of coronary stents. One basic stent design in two configurations (dogbone, DB; non-dogbone, NDB) was used. Vascular injury was determined according to a modified injury score (IS). Results: Standardized experimental conditions ensured comparable vessel dimensions and overstretch data. DB stents caused more severe IS compared to NDB stents. The mean IS and the IS at the distal end of all stents were significantly reduced for NDB stents (ISMean, DB, 1.16 ±0.12; NDB, 1.02 ±0.12; p=0.018; ISDist, DB, 1.39 ±0.28; NDB, 1.13 ±0.24; p=0.03). Discussion/Conclusion: The introduced ex-vivo model allowed the evaluation of different stent designs exclude unfavorable stent designs. KW - Stent screening KW - Stent design KW - Injury score KW - Ex vivo porcine stent model Y1 - 2022 U6 - https://doi.org/10.1159/000527883 SN - 1421-9921 VL - 63 IS - 4 SP - 285 EP - 293 PB - Karger CY - Basel ER - TY - JOUR A1 - Geith, Markus A. A1 - Nothdurfter, Laurenz A1 - Heiml, Manuel A1 - Agrafiotis, Emmanouil A1 - Gruber, Markus A1 - Sommer, Gerhard A1 - Schratzenstaller, Thomas A1 - Holzapfel, Gerhard A. T1 - Quantifying stent-induced damage in coronary arteries by investigating mechanical and structural alterations JF - Acta Biomaterialia N2 - Vascular damage develops with diverging severity during and after percutaneous coronary intervention with stent placement and is the prevailing stimulus for in-stent restenosis. Previous work has failed to link mechanical data obtained in a realistic in vivo or in vitro environment with data collected during imaging processes. We investigated whether specimens of porcine right coronary arteries soften when indented with a stent strut shaped structure, and if the softening results from damage mechanisms inside the fibrillar collagen structure. To simulate the multiaxial loading scenario of a stented coronary artery, we developed the testing device ‘LAESIO’ that can measure differences in the stress-stretch behavior of the arterial wall before and after the indentation of a strut-like stamp. The testing protocol was optimized according to preliminary experiments, more specifically equilibrium and relaxation tests. After chemical fixation of the specimens and subsequent tissue clearing, we performed three-dimensional surface and second-harmonic generation scans on the deformed specimens. We analyzed and correlated the mechanical response with structural parameters of high-affected tissue located next to the stamp indentation and low-affected tissue beyond the injured area. The results reveal that damage mechanisms, like tissue compression as well as softening, fiber dispersion, and the lesion extent, are direction-dependent, and the severity of them is linked to the strut orientation, indentation pressure, and position. The findings highlight the need for further investigations by applying the proposed methods to human coronary arteries. Additional data and insights might help to incorporate the observed damage mechanisms into material models for finite element analyses to perform more accurate simulations of stent-implantations. KW - Percutaneous coronary intervention KW - Stent KW - Mechanical properties KW - Damage mechanism KW - Vascular injury KW - Coronary artery KW - Indentation test KW - Softening KW - Second-harmonic generation imaging KW - Micro-structure Y1 - 2020 U6 - https://doi.org/10.1016/j.actbio.2020.08.016 VL - 116 IS - October SP - 285 EP - 301 PB - Elsevier ER - TY - JOUR A1 - Wiesent, Lisa A1 - Schultheiss, Ulrich A1 - Schmid, Christof A1 - Schratzenstaller, Thomas A1 - Nonn, Aida T1 - Experimentally validated simulation of coronary stents considering different dogboning ratios and asymmetric stent positioning JF - PlOS One N2 - In-stent restenosis remains a major problem of arteriosclerosis treatment by stenting. Expansion-optimized stents could reduce this problem. With numerical simulations, stent designs/ expansion behaviours can be effectively analyzed. For reasons of efficiency, simplified models of balloon-expandable stents are often used, but their accuracy must be challenged due to insufficient experimental validation. In this work, a realistic stent life-cycle simulation has been performed including balloon folding, stent crimping and free expansion of the balloon-stent-system. The successful simulation and validation of two stent designs with homogenous and heterogeneous stent stiffness and an asymmetrically positioned stent on the balloon catheter confirm the universal applicability of the simulation approach. Dogboning ratio, as well as the final dimensions of the folded balloon, the crimped and expanded stent, correspond well to the experimental dimensions with only slight deviations. In contrast to the detailed stent life-cycle simulation, a displacement-controlled simulation can not predict the transient stent expansion, but is suitable to reproduce the final expanded stent shape and the associated stress states. The detailed stent life-cycle simulation is thus essential for stent expansion analysis/optimization, whereas for reasons of computational efficiency, the displacement-controlled approach can be considered in the context of pure stress analysis. KW - Catheters KW - Coronary stenting KW - Deformation KW - Stent implantation KW - Stiffness KW - Stent KW - Ballondilatation KW - Numerische Strömungssimulation Y1 - 2019 U6 - https://doi.org/10.1371/journal.pone.0224026 VL - 14 IS - 10 SP - 1 EP - 25 PB - PLOS ER - TY - JOUR A1 - Geith, Markus A. A1 - Swidergal, Krzysztof A1 - Hochholdinger, Bernd A1 - Schratzenstaller, Thomas A1 - Wagner, Marcus A1 - Holzapfel, Gerhard A. T1 - On the importance of modeling balloon folding, pleating, and stent crimping: An FE study comparing experimental inflation tests JF - International Journal for Numerical Methods in Biomedical Engineering N2 - Finite element (FE)–based studies of preoperative processes such as folding,pleating, and stent crimping with a comparison with experimental inflation tests are not yet available. Therefore, a novel workflow is presented in which residual stresses of balloon folding and pleating, as well as stent crimping, and the geometries of all contact partners were ultimately implemented in an FE code to simulate stent expansion by using an implicit solver. The numerical results demonstrate that the incorporation of residual stresses and strains experienced during the production step significantly increased the accuracy of the subsequent simulations, especially of the stent expansion model. During the preoperative processes, stresses inside the membrane and the stent material also reached a rather high level. Hence, there can be no presumption that balloon catheters or stents are undamaged before the actual surgery. The implementation of the realistic geometry, in particular the balloon tapers, and the blades of the process devices improved the simulation of the expansion mech-anisms, such as dogboning, concave bending, or overexpansion of stent cells. This study shows that implicit solvers are able to precisely simulate the mentioned preoperative processes and the stent expansion procedure without a preceding manipulation of the simulation time or physical mass. KW - Catheter KW - Coronary KW - Crimping KW - Finite element KW - Stent KW - Stent KW - Implantation KW - Simulation KW - Finite-Elemente-Methode Y1 - 2019 U6 - https://doi.org/10.1002/cnm.3249 N1 - This study was funded by the Bavarian Research Foundation within the project “PIZ‐225‐18” VL - 35 IS - 11 PB - Wiley ER -