TY - CHAP A1 - Müller, Stefan A1 - Danner, Christian A1 - Breidbach, Jörg A1 - Seidl, Markus A1 - Hußlein, Thomas A1 - Lauf, Wolfgang T1 - Stochastic Modeling of Throughput Times of Supplier Parts for an Automotive Plant T2 - Angewandte Forschung in der Wirtschaftsinformatik - Prozesse, Technologie, Anwendungen, Systeme und Management 2014: Tagungsband zur 27. AKWI-Jahrestagung vom 07. bis zum 10.09.2014 an der Oberbayerischen Technischen Hochschule Regensburg N2 - For modern production industries optimized supply of parts is a critical success factor. Especially in the automotive industry, the reliable supply of painted bodies for the fi nal assembly is essential for OEMs considering just in time or just in sequence processes. Additionally one central cost target is the avoidance of resorting for JIT/JIS processes. An essential workfl ow analysis is therefore the basis for making strategic or operational decisions such as the adjustment of the plant structure or increasing the number of products and variants manufactured simultaneously. In order to support strategic planning using simulation and planning systems, the modeling of the production process is required. This is particularly important for scheduling as no real manufacturing data is available and therefore prognosis based on the model are essential. Due to the short time and the limited human resources for a detailed modeling, it is essential to create a robust model with good accuracy and reduced complexity Y1 - 2014 SN - 978-3-936527-38-4 U6 - https://doi.org/10.15771/978-3-936527-38-4 SP - 35 EP - 43 S PB - News & Media ER - TY - CHAP A1 - Escher, Lukas A1 - Müller, Max A1 - Rück, Thomas A1 - Jobst, Simon A1 - Bierl, Rudolf T1 - Digitaler Zwilling photoakustischer Spurengassensoren zur Prozessüberwachung T2 - 16. Dresdner Sensor-Symposium 2022: Vorträge N2 - Stickstoffdioxid (NO2) wird hauptsächlich durch anthropogene Verbrennungsprozesse in Verkehr und Industrie in die Umgebungsluft eingebracht [1]. Die stark reaktive, oxidative Wirkung von NO2 kann bei Exposition mit höheren Konzentrationen Reizungen und allergische Reaktionen in den Atemwegen hervorrufen. Weiter führt NO2 zur Bildung von saurem Regen, Smog und Ozon (O3) die sich ebenso negativ auf die menschliche Gesundheit und Umwelt auswirken [2,3]. Aufgrund dieser Effekte wird die Spurengaskonzentration von NO2 in der Luft in Deutschland an ausgewählten, verkehrsreichen Orten gemessen. Y1 - 2022 SN - 978-3-9819376-7-1 U6 - https://doi.org/10.5162/16dss2022/3.3 PB - AMA (Association for Sensors + Measurement) ER - TY - JOUR A1 - Rück, Thomas A1 - Pangerl, Jonas A1 - Escher, Lukas A1 - Jobst, Simon A1 - Müller, Max A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Kinetic cooling in mid-infrared methane photoacoustic spectroscopy: A quantitative analysis via digital twin verification JF - Photoacoustics N2 - This study presents a detailed quantitative analysis of kinetic cooling in methane photoacoustic spectroscopy, leveraging the capabilities of a digital twin model. Using a quantum cascade laser tuned to 1210.01 cm⁻¹, we investigated the effects of varying nitrogen-oxygen matrix compositions on the photoacoustic signals of 15 ppmV methane. Notably, the photoacoustic signal amplitude decreased with increasing oxygen concentration, even falling below the background signal at oxygen levels higher than approximately 6 %V. This phenomenon was attributed to kinetic cooling, where thermal energy is extracted from the surrounding gas molecules rather than added, as validated by complex vector analysis using a previously published digital twin model. The model accurately reproduced complex signal patterns through simulations, providing insights into the underlying molecular mechanisms by quantifying individual collision contributions. These findings underscore the importance of digital twins in understanding the fundamentals of photoacoustic signal generation at the molecular level. Y1 - 2024 U6 - https://doi.org/10.1016/j.pacs.2024.100652 VL - 40 PB - Elsevier ER - TY - JOUR A1 - Lautenschläger, Toni A1 - Leis, Alexander A1 - Dendorfer, Sebastian A1 - Palm, Christoph A1 - Schreiner, Rupert A1 - Langer, Christoph A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian A1 - Dams, Florian A1 - Bornmann, Benjamin A1 - Navitski, Aliaksandr A1 - Serbun, Pavel A1 - Müller, Günter A1 - Liebetruth, Thomas A1 - Kohlert, Dieter A1 - Pernsteiner, Jochen A1 - Schreier, Franz A1 - Heerklotz, Sabrina A1 - Heerklotz, Allwin A1 - Boos, Alexander A1 - Herwald, Dominik A1 - Monkman, Gareth J. A1 - Treiber, Daniel A1 - Mayer, Matthias A1 - Hörner, Eva A1 - Bentz, Alexander A1 - Shamonin (Chamonine), Mikhail A1 - Johansen, Søren Peter A1 - Reichel, Marco A1 - Stoll, Andrea A1 - Briem, Ulrich A1 - Dullien, Silvia A1 - Renkawitz, Tobias A1 - Weber, Tim A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Penzkofer, Rainer A1 - Barnsteiner, K. A1 - Jovanovik, M. A1 - Wernecke, P. A1 - Vögele, A. A1 - Bachmann, T. A1 - Plötz, Martin A1 - Schliekmann, Claus A1 - Wels, Harald A1 - Helmberger, Paul A1 - Kaspar, Marcel A1 - Hönicka, M. A1 - Schrammel, Siegfried A1 - Enser, Markus A1 - Schmidmeier, Monika A1 - Schroll-Decker, Irmgard A1 - Haug, Sonja A1 - Gelfert, Verena A1 - Vernim, Matthias ED - Baier, Wolfgang T1 - Forschungsbericht 2012 T3 - Forschungsberichte der OTH Regensburg - 2012 Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-7834 CY - Regensburg ER - TY - JOUR A1 - Foltan, Maik A1 - Dinh, D. A1 - Gruber, Michael A1 - Müller, Thomas A1 - Hart, C. A1 - Krenkel, Lars A1 - Schmid, C. A1 - Lehle, Karla T1 - Incidence of neutrophil extracellular traps (NETs) in different membrane oxygenators: pilot in vitro experiments in commercially available coated membranes JF - Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs N2 - Neutrophil extracellular traps (NETs) were detected in blood samples and in cellular deposits of oxygenator membranes during extracorporeal membrane oxygenation (ECMO) therapy and may be responsible for thrombogenesis. The aim was to evaluate the effect of the base material of gas fiber (GF, polymethylpentene) and heat exchange (HE) membranes and different antithrombogenic coatings on isolated granulocytes from healthy volunteers under static culture conditions. Contact of granulocytes with membranes from different ECMO oxygenators (with different surface coatings) and uncoated-GFs allowed detection of adherent cells and NETotic nuclear structures (normal, swollen, ruptured) using nuclear staining. Flow cytometry was used to identify cell activation (CD11b/CD62L, oxidative burst) of non-adherent cells. Uncoated-GFs were used as a reference. Within 3 h, granulocytes adhered to the same extent on all surfaces. In contrast, the ratio of normal to NETotic cells was significantly higher for uncoated-GFs (56-83%) compared to all coated GFs (34-72%) (p < 0.001) with no difference between the coatings. After material contact, non-adherent cells remained vital with unchanged oxidative burst function and the proportion of activated cells remained low. The expression of activation markers was independent of the origin of the GF material. In conclusion, the polymethylpentene surfaces of the GFs already induce NET formation. Antithrombogenic coatings can already reduce the proportion of NETotic nuclei. However, it cannot be ruled out that NET formation can induce thrombotic events. Therefore, new surfaces or coatings are required for future ECMO systems and long-term implantable artificial lungs. Y1 - 2025 U6 - https://doi.org/10.1007/s10047-024-01486-4 ER - TY - JOUR A1 - Pangerl, Jonas A1 - Moser, Elisabeth A1 - Müller, Max A1 - Weigl, Stefan A1 - Jobst, Simon A1 - Rück, Thomas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - A sub-ppbv-level Acetone and Ethanol Quantum Cascade Laser Based Photoacoustic Sensor– Characterization and Multi-Component Spectra Recording in Synthetic Breath JF - Photoacoustics N2 - Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8263 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbv in terms of ethanol and 250 pptv regarding acetone, our system is among the best performing presented so far. KW - Acetone KW - Breath analysis KW - Photoacoustic spectroscopy KW - Quantum cascade laser KW - Spectral simulation Y1 - 2023 U6 - https://doi.org/10.1016/j.pacs.2023.100473 SN - 2213-5979 N1 - Corresponding author: Jonas Pangerl VL - 30 SP - 1 EP - 12 PB - Elsevier ER - TY - CHAP A1 - Weigl, Stefan A1 - Müller, Max A1 - Pangerl, Jonas A1 - Rück, Thomas T1 - Scopes and Limits of Photoacoustic Spectroscopy in Modern Breath Analysis T2 - Breath Analysis N2 - Photoacoustic spectroscopy is a viable tool for trace gas detection in various application fields. In recent years, this technique has been exploited more and more for modern breath analysis as well. Within this chapter, a holistic overview of photoacoustic spectroscopy is presented, while maintaining the relationship to breath analysis. Therefore, a concise description of the fundamentals of photoacoustic spectroscopy is provided. This is essential for understanding the scopes and limits of this outstanding measurement technique being described within this chapter. In the past several different types of photoacoustic measurement setups for trace gas detection have emerged, including different light sources, modulation techniques, and detection schemes. These are described shortly and advantages as well as disadvantages, especially in relation to breath analysis, are highlighted. Though being a promising sensor principle, measurement devices based on photoacoustic spectroscopy are still rare on the sensor market, especially when it comes to trace gas detection in complex gas matrices, e.g., human breath exhale. One main reason is due to possible molecular interactions influencing the relaxational behavior of the analyte altering the sensor signal. Recent results shedding light on the intricate relaxational processes within complex gas matrices are discussed in detail, providing approaches to overcome this issue. Finally, various applications of photoacoustic spectroscopy in breath analysis are described demonstrating the great potential of this technology. Y1 - 2022 SN - 978-3-031-18526-7 U6 - https://doi.org/10.1007/11663_2022_22 SP - 101 EP - 159 PB - Springer nature ER - TY - JOUR A1 - Steiger, Tamara A1 - Foltan, Maik A1 - Philipp, Alois A1 - Müller, Thomas A1 - Gruber, Michael A1 - Bredthauer, Andre A1 - Krenkel, Lars A1 - Birkenmaier, Clemens A1 - Lehle, Karla T1 - Accumulations of von Willebrand factor within ECMO oxygenators: Potential indicator of coagulation abnormalities in critically ill patients? JF - Artificial Organs N2 - Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots-in particular, the presence of von Willebrand factor (vWF)-may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti-vWF and anti-P-selectin) and counterstained with 4 ',6-diamidino-2-phenylindole. The extent of vWF-loading was correlated with patient and technical data. While 12 MOs showed low vWF-loadings, 9 MOs showed high vWF-loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF-fibers/"cobwebs," leukocytes, platelet-leukocyte aggregates (PLAs), and P-selectin-positive platelet aggregates were independent of the extent of vWF-loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high-molecular-weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy. KW - ECMO KW - PLATELET ACTIVATION KW - THROMBOSIS KW - BLOOD FLOW KW - INFLAMMATION Y1 - 2019 U6 - https://doi.org/10.1111/aor.13513 SN - 1525-1594 VL - 43 IS - 11 SP - 1065 EP - 1076 PB - Wiley CY - Hoboken ER - TY - INPR A1 - Pangerl, Jonas A1 - Moser, Elisabeth A1 - Müller, Max A1 - Weigl, Stefan A1 - Jobst, Simon A1 - Rück, Thomas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - A Highly Sensitive Acetone and Ethanol Quantum Cascade Laser Based Photoacoustic Sensor: Characterization and Multi-Component Spectra Recording in Synthetic Breath T2 - SSRN Electronic Journal N2 - Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8260 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbV in terms of ethanol and 250 pptV regarding acetone, our system is among the best performing presented so far. KW - Photoacoustic spectroscopy KW - quantum cascade laser KW - spectral simulation KW - breath analysis KW - acetone Y1 - 2022 U6 - https://doi.org/10.2139/ssrn.4305376 PB - Elsevier ER - TY - JOUR A1 - Haus, Moritz A1 - Foltan, Maik A1 - Philipp, Alois A1 - Müller, Thomas A1 - Lingel, Maximilian P. A1 - Krenkel, Lars A1 - Gruber, Michael A1 - Lehle, Karla T1 - Neutrophil extracellular traps -a potential trigger for the development of thrombocytopenia during extracorporeal membrane oxygenation N2 - Neutrophil extracellular traps (NETs) have recently emerged as a potential link between inflammation, immunity, and thrombosis, as well as other coagulation disorders which present a major challenge in the context of extracorporeal membrane oxygenation (ECMO). By examining blood from ECMO patients for NETs and their precursors and correlating them with clinical and laboratory biomarkers of coagulation and inflammation, this study aims to evaluate the association between the presence of NETs in the bloodstream of ECMO patients and the development of potentially severe coagulation disorders during ECMO therapy. Therefore, blood samples were collected from healthy volunteers (n=13) and patients receiving veno-venous (VV) ECMO therapy (n=10). To identify NETs and their precursors, DNA and myeloperoxidase as well as granulocyte marker CD66b were visualized simultaneously by immunofluorescence staining in serial blood smears. Differentiation of DNA-containing objects and identification of NETs and their precursors was performed semiautomatically by a specific algorithm using the shape and size of DNA staining and the intensity of MPO and CD66b signal. Neutrophil extracellular traps and their precursors could be detected in blood smears from patients requiring VV ECMO. Compared to volunteers, ECMO patients presented significantly higher rates of NETs and NET precursors as well as an increased proportion of neutrophil granulocytes in all detected nucleated cells. A high NET rate prior to the initiation of ECMO therapy was associated with both increased iL-6 and TNF-α levels as an expression of a high cytokine burden. These patients with increased NET release also presented an earlier and significantly more pronounced decrease in platelet counts and ATIII activity following initiation of therapy compared with patients with less elevated NETs. These findings provide further indications for the development of immune-mediated acquired thrombocytopenia in ECMO patients. KW - Neutrophil extracellular traps (NET) KW - Immunoflorescence KW - Thrombocytopenia KW - Extracorporeal membrane oxygenation (ECMO) KW - Sepsis KW - immunothrombosis KW - Coagulation disorder Y1 - 2024 UR - https://www.frontiersin.org/journals/immunology/articles/10.3389/fimmu.2024.1339235/abstract U6 - https://doi.org/10.3389/fimmu.2024.1339235 VL - 15 PB - frontiers ER - TY - JOUR A1 - Klein, C. A1 - Nabbefeld, T. A1 - Hattab, H. A1 - Meyer, D. A1 - Jnawali, G. A1 - Kammler, Martin A1 - Meyer zu Heringdorf, Frank-Joachim A1 - Golla-Franz, A. A1 - Müller, B. H. A1 - Schmidt, Thomas A1 - Henzler, M. A1 - Horn-von Hoegen, Michael T1 - Lost in reciprocal space? Determination of the scattering condition in spot profile analysis low-energy electron diffraction JF - Review of scientific instruments N2 - The precise knowledge of the diffraction condition, i.e., the angle of incidence and electron energy, is crucial for the study of surface morphology through spot profile analysis low-energy electron diffraction (LEED). We demonstrate four different procedures to determine the diffraction condition: employing the distortion of the LEED pattern under large angles of incidence, the layer-by-layer growth oscillations during homoepitaxial growth, a G(S) analysis of a rough surface, and the intersection of facet rods with 3D Bragg conditions. Y1 - 2011 U6 - https://doi.org/10.1063/1.3554305 VL - 82 IS - 3 PB - American Institute of Physics ER - TY - GEN A1 - Weber, Karsten A1 - Sonar, Arne A1 - Gerhards, Helene A1 - Bittner, Uta A1 - Krug, Henriette A1 - Reuter-Oppermann, Melanie A1 - Pumplun, Luisa A1 - Müller, Helene A1 - Buxmann, Peter A1 - Schneider, Diana A1 - Zoglauer, Thomas ED - Sonar, Arne ED - Weber, Karsten T1 - Künstliche Intelligenz und Gesundheit BT - Ethische, philosophische und sozialwissenschaftliche Explorationen N2 - Der Einsatz von künstlicher Intelligenz im Gesundheitsbereich verspricht besonders großen Nutzen durch eine bessere Versorgung sowie effizientere Abläufe und bietet damit letztlich auch ökonomische Vorteile. Dem stehen unter anderem Befürchtungen entgegen, dass sich durch den Einsatz von künstlicher Intelligenz das Arzt-Patienten-Verhältnis verändern könnte, Arbeitsplätze gefährdet seien oder die Ökonomisierung des Gesundheitswesens einen weiteren Schub erfahren könnte. Zuweilen wird die Debatte um diese Technologie, zumal in der Öffentlichkeit, emotional und fern sachlicher Argumente geführt. Die Autorinnen und Autoren untersuchen die Geschichte des KI-Einsatzes in der Medizin, deren öffentliche Wahrnehmung, Governance der KI, die Möglichkeiten und Grenzen der Technik sowie Einsatzgebiete, die bisher noch nicht oder nur wenig im Fokus der Aufmerksamkeit waren. Dabei erweist sich die KI als leistungsfähiges Werkzeug, das zahlreiche ethische und soziale Fragen aufwirft, die bei der Einführung anderer Technologien bereits gestellt wurden; allerdings gibt es auch neue Herausforderungen, denen sich Professionen, Politik und Gesellschaft stellen müssen. KW - Ethik KW - Künstliche Intelligenz KW - Gesundheit KW - Technikfolgenabschätzung Y1 - 2022 SN - 978-3-515-12977-0 U6 - https://doi.org/10.25162/9783515129770 PB - Franz Steiner CY - Stuttgart ER - TY - JOUR A1 - Beyer, Thomas A1 - Weigert, Markus A1 - Quick, Harald H. A1 - Pietrzyk, Uwe A1 - Vogt, Florian A1 - Palm, Christoph A1 - Antoch, Gerald A1 - Müller, Stefan P. A1 - Bockisch, Andreas T1 - MR-based attenuation correction for torso-PET/MR imaging BT - pitfalls in mapping MR to CT data JF - European Journal of Nuclear Medicine and Molecular Imaging N2 - Purpose MR-based attenuation correction (AC) will become an integral part of combined PET/MR systems. Here, we propose a toolbox to validate MR-AC of clinical PET/MRI data sets. Methods Torso scans of ten patients were acquired on a combined PET/CT and on a 1.5-T MRI system. MR-based attenuation data were derived from the CT following MR–CT image co-registration and subsequent histogram matching. PET images were reconstructed after CT- (PET/CT) and MR-based AC (PET/MRI). Lesion-to-background (L/B) ratios were estimated on PET/CT and PET/MRI. Results MR–CT histogram matching leads to a mean voxel intensity difference in the CT- and MR-based attenuation images of 12% (max). Mean differences between PET/MRI and PET/CT were 19% (max). L/B ratios were similar except for the lung where local misregistration and intensity transformation leads to a biased PET/MRI. Conclusion Our toolbox can be used to study pitfalls in MR-AC. We found that co-registration accuracy and pixel value transformation determine the accuracy of PET/MRI. KW - PET/MRI KW - PET/CT KW - Attenuation correction KW - Kernspintomografie KW - Positronen-Emissions-Tomografie KW - Schwächung Y1 - 2008 U6 - https://doi.org/10.1007/s00259-008-0734-0 VL - 35 IS - 6 SP - 1142 EP - 1146 ER -