TY - RPRT A1 - Andratschke, Christin A1 - Ceullo, Laura A1 - Dawoud, Belal A1 - Draeger, Susan A1 - Gerdes, Thorsten A1 - Giebisch, Matthias A1 - Grießhammer, Peter A1 - Haas, Katharina A1 - Haug, Sonja A1 - Helling, Dominik A1 - Kominis, Lena A1 - Lang, Christian A1 - Malz, Sebastian A1 - Melzl, Johannes A1 - Michlbauer, David A1 - Mühlberger, Thomas A1 - Nagl, Klaus A1 - Preis, Michael A1 - Rechenauer, Christian A1 - Riederer, Michael A1 - Rückerl, Alexander A1 - Saller, Tobias A1 - Schnabl, Andreas A1 - Stadler, Michael A1 - Steffens, Oliver A1 - Steininger, Peter A1 - Stelzl, André A1 - Toutouly, Lovis A1 - Trauner, Matthias A1 - Vetter, Miriam A1 - Walbrunn, Johannes A1 - Weber, Karsten A1 - Zielbauer, Lukas ED - Steffens, Oliver T1 - MAGGIE: Energetische Modernisierung des genossenschaftlichen Wohnquartiers Margaretenau in Regensburg BT - Musterlösungen für solaroptimiertes Wohnen mit innovativen solaraktiven Baustoffen und einem KI-gestützten Energiemanagement für eine netzdienliche, emissionsarme Strom- und Wärmelogistik; Ergebnisbericht N2 - Im Projekt MAGGIE wurden für das genossenschaftliche historische Stadtquartier „Margaretenau“ in Regensburg Musterlösungen für energieoptimiertes Wohnen mit innovativen Wandaufbauten aus solaraktiven Baukonstruktionen und einer vorhersagebasierten Versorgungstechnologie erforscht. Dazu wurde ein bestehendes Wohngebäude als Demonstrations- und Versuchsobjekt mit einem neuartigen, besonders effizienten Hybridsystem aus Wärmepumpentechnologie und Kraft- Wärme-Kopplung ausgestattet und untersucht, ergänzt durch eine dynamische Wärmelogistik zur Verringerung von Verteilungsverlusten. Das System wurde durch ein neu entwickeltes, allgemein einsetzbares Planungs-, Optimierungs- und Steuerungstool ausgelegt und im Betrieb geregelt. Die in Echtzeit laufende Nachoptimierung des Systems während des Betriebs greift dabei auf reale Monitoringdaten zu. Die Einbindung von Nutzerbedarfsprofilen, Strombörse und Wetterdaten in die Steuerung gestattet einen dynamischen und perspektivischen Anlagenbetrieb zur Maximierung der Solar- und Umweltwärme-Anteile der Energieversorgung und leistet damit einen wirksamen Beitrag zu einem emissionsarmen, klimafreundlichen Gebäudebetrieb. Für die denkmalgerechte Modernisierung der historischen Fassaden wurde ein solaraktives und solaradaptives Außenputzsystem entwickelt und in der Realität getestet. Am Bestandsgebäude kam anstelle eines Wärmedämmverbundsystems ein innovativer Dämmputz mit Mikrohohlglaskugeln zum Einsatz. Die Skalierbarkeit erlaubt eine abschnittsweise Modernisierung des gesamten Ensembles über mehrere Jahre. Durch die hohe Energieeffizienz wird die Warmmiete für die Bewohner der genossenschaftlichen Siedlung durch die Modernisierungsmaßnahmen nicht erhöht, so dass auch nach der Modernisierung ein bezahlbares Wohnen sichergestellt wird. KW - Altbaumodernisierung KW - Energieeinsparung KW - Energiebewusstes Bauen KW - Haus Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-53354 SN - 978-3-96256-100-0 N1 - Gefördert durch einen Beschluss des Bundestages durch das Bundesministerium für Wirtschaft und Klimaschutz (BMWK); Projektlaufzeit Oktober 2017 bis Juni 2022; Förderkennzeichen 03SBE0007A–E N1 - korrigierte Version unter: https://doi.org/10.35096/othr/pub-5901 CY - Regensburg ER - TY - RPRT A1 - Andratschke, Christin A1 - Ceullo, Laura A1 - Dawoud, Belal A1 - Draeger, Susan A1 - Gerdes, Thorsten A1 - Giebisch, Matthias A1 - Grießhammer, Peter A1 - Haas, Katharina A1 - Haug, Sonja A1 - Helling, Dominik A1 - Kominis, Lena A1 - Lang, Christian A1 - Malz, Sebastian A1 - Melzl, Johannes A1 - Michlbauer, David A1 - Mühlberger, Thomas A1 - Nagl, Klaus A1 - Preis, Michael A1 - Rechenauer, Christian A1 - Riederer, Michael A1 - Rückerl, Alexander A1 - Saller, Tobias A1 - Schnabl, Andreas A1 - Stadler, Michael A1 - Steffens, Oliver A1 - Steininger, Peter A1 - Stelzl, André A1 - Toutouly, Lovis A1 - Trauner, Matthias A1 - Vetter, Miriam A1 - Walbrunn, Johannes A1 - Weber, Karsten A1 - Zielbauer, Lukas ED - Steffens, Oliver T1 - MAGGIE: Energetische Modernisierung des genossenschaftlichen Wohnquartiers Margaretenau in Regensburg BT - Musterlösungen für solaroptimiertes Wohnen mit innovativen solaraktiven Baustoffen und einem KI-gestützten Energiemanagement für eine netzdienliche, emissionsarme Strom- und Wärmelogistik; Ergebnisbericht N2 - Im Projekt MAGGIE wurden für das genossenschaftliche historische Stadtquartier „Margaretenau“ in Regensburg Musterlösungen für energieoptimiertes Wohnen mit innovativen Wandaufbauten aus solaraktiven Baukonstruktionen und einer vorhersagebasierten Versorgungstechnologie erforscht. Dazu wurde ein bestehendes Wohngebäude als Demonstrations- und Versuchsobjekt mit einem neuartigen, besonders effizienten Hybridsystem aus Wärmepumpentechnologie und Kraft- Wärme-Kopplung ausgestattet und untersucht, ergänzt durch eine dynamische Wärmelogistik zur Verringerung von Verteilungsverlusten. Das System wurde durch ein neu entwickeltes, allgemein einsetzbares Planungs-, Optimierungs- und Steuerungstool ausgelegt und im Betrieb geregelt. Die in Echtzeit laufende Nachoptimierung des Systems während des Betriebs greift dabei auf reale Monitoringdaten zu. Die Einbindung von Nutzerbedarfsprofilen, Strombörse und Wetterdaten in die Steuerung gestattet einen dynamischen und perspektivischen Anlagenbetrieb zur Maximierung der Solar- und Umweltwärme-Anteile der Energieversorgung und leistet damit einen wirksamen Beitrag zu einem emissionsarmen, klimafreundlichen Gebäudebetrieb. Für die denkmalgerechte Modernisierung der historischen Fassaden wurde ein solaraktives und solaradaptives Außenputzsystem entwickelt und in der Realität getestet. Am Bestandsgebäude kam anstelle eines Wärmedämmverbundsystems ein innovativer Dämmputz mit Mikrohohlglaskugeln zum Einsatz. Die Skalierbarkeit erlaubt eine abschnittsweise Modernisierung des gesamten Ensembles über mehrere Jahre. Durch die hohe Energieeffizienz wird die Warmmiete für die Bewohner der genossenschaftlichen Siedlung durch die Modernisierungsmaßnahmen nicht erhöht, so dass auch nach der Modernisierung ein bezahlbares Wohnen sichergestellt wird. KW - Altbaumodernisierung KW - Energieeinsparung KW - Energiebewusstes Bauen KW - Haus Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-59011 SN - 978-3-96256-100-0 N1 - Gefördert durch einen Beschluss des Bundestages durch das Bundesministerium für Wirtschaft und Klimaschutz (BMWK); Projektlaufzeit Oktober 2017 bis Juni 2022; Förderkennzeichen 03SBE0007A–E CY - Regensburg ER - TY - BOOK A1 - Steffens, Oliver T1 - On Media, typewriters, logic and truth: Essays N2 - Essays on the Media Revolution in the 19th Century, when sound recording, film and typewriter changed the way of communication, literature, and arts; on the societal impact and role models that came along with the invention and success of the typewriting machine; on early mathematical and mechanistic ways of reasoning the medieval philosopher Ramón Llull, Leibniz's idea of binary numbers and the advent of artificial intelligence. KW - History of technology KW - typewriter KW - media KW - cultural impact KW - motion picture KW - inventions KW - female roles KW - slide rules KW - Ramon Llull KW - combinatorics KW - thinking machine KW - artificial intelligence Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-58380 CY - Regensburg ER - TY - CHAP A1 - Falter, Thomas A1 - Goldberg, Boris A1 - Günther, Swen A1 - Steffens, Oliver ED - Borowski, Esther ED - Cernavin, Oleg ED - Hees, Frank ED - Joerißen, Theresa T1 - Transfererfolg messbar machen BT - Von der Idee über die Implementierung zur Anwendung mit Transferindikatorik im Forschungsbetrieb T2 - Erfolgreicher Transfer in der Arbeitsgestaltung N2 - Hochschulen für angewandte Wissenschaften (HAW) kommt als regionalen Innovationstreibern eine gesellschaftliche Verantwortung durch ihre Zusammenarbeit mit Unternehmen und Gesellschaft zu. Diese Zusammenarbeit geschieht im Rahmen von Aktivitäten des Wissens- und Technologietransfers. Die Beurteilung des Erfolgs dieser Transferaktivitäten verursacht jedoch regelmäßig Schwierigkeiten, da geeignete Indikatoren zur Erfolgsmessung fehlen. Im Rahmen des vom Bundesministerium für Bildung und Forschung (BMBF) geförderten Verbundforschungsprojektes Transfer_i wurde ein Modell zur Objektivierung und Messung von Forschungsleistung, forschungsbasiertem Transfer sowie dessen Umsetzung am Markt in Form von Innovationen erarbeitet. Mit dem Forschungsprojekt wurden kausale Zusammenhänge für das Gelingen von Transfer identifiziert und daraufhin entsprechende Indikatoren definiert, um auf dieser Basis die Steuerung von Transferprozessen zu ermöglichen. In diesem Beitrag werden zwei im Projekt Transfer_i entwickelte Modelle und Indikatoren vorgestellt, die die Voraussetzungen für einen erfolgreichen Transferprozess abbilden können. Auf dieser Grundlage zeigen wir anhand eines Projekts (MAGGIE) der Ostbayerischen Technischen Hochschule (OTH) Regensburg mit mehreren regionalen Partnern, wie die vorher definierten Modelle und Indikatoren in einem konkreten Anwendungsfall verwendet werden können. Abschließend beschreiben wir die erforderlichen Rahmenbedingungen für die erfolgreiche Umsetzung von Transfer an Hochschulen und wie darauf bezogene Indikatoren effektiv eingeführt werden können. KW - Angewandte Forschung KW - Transfer Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-67568 UR - https://www.waxmann.com/index.php?eID=download&buchnr=4808 SP - 173 EP - 187 PB - Waxmann CY - Münster ER - TY - JOUR A1 - Schloplocher, Paul Dragos A1 - Ettengruber, Stefan A1 - Steffens, Oliver T1 - Improvements for building-performance simulations by a comparative finite-element method analysis JF - Energy and Buildings N2 - This paper presents a method to improve building-performance simulations (BPS) by the comparison and analysis of different approaches based on finite-element method (FEM) models. The lumped parameter method (LPM) is used in several BPS programs and tools. It has the advantage of fast computing times and comparably good accuracy for thermal and energy loads. With the help of detailed FEM simulations, it is possible to further improve the degree of detail and accuracy while maintaining the high simulation speed. In this work, we compare time-dependent results for local temperatures in a generic reference room within a given periode of time. In a second step, the differences between the models with respect to various physical effects are analyzed and used to introduce additional equations into the LPM model in order to improve its accuracy. Thus, we discuss potentials for improvement for BPS and demonstrate a method of a practical implementation. The results show minor differences of less than 0.1 K for radiation and heat transfer, so their level of detail in BPS is appropriate. In these terms, no improvements were pursued within the work. However, the FEM simulation is capable of calculating the internal convective heat transfer and thermal bridges more accurately due to the use of computational fluid dynamics (CFD) and the geometrically precise representation of the FEM model. Here, deviations of up to 1 K in room temperature (convective heat transfer) and up to 0.5 K in wall temperatures (thermal bridges) were pointed out. By improving the LPM with equations obtained from the FEM, these deviations can be reduced to less than 0.2 K, which is a considerable improvement in accuracy. KW - Lumped parameter model KW - Finite-element method KW - Building performance simulation Y1 - 2023 U6 - https://doi.org/10.1016/j.enbuild.2022.112563 N1 - Corresponding author: Dragos Paul Schoplocher VL - 278 SP - 1 EP - 12 PB - Elsevier ER - TY - INPR A1 - Malz, Sebastian A1 - Sindersberger, Dirk A1 - Monkman, Gareth J. A1 - Steffens, Oliver A1 - Kusterle, Wolfgang T1 - Determination of the Water Content within Tunnel Linings to Assess Fire Safety T2 - SSRN Electronic Journal N2 - Fires in tunnels are known to lead to explosive spalling of the tunnel linings, mainly due to rapid expansion of water as a result of vaporization in the concrete. In order to determine water content and assess fire safety within tunnel linings a novel measurement system has been developed. The development process includes the calibration of the sensor system via both direct and indirect approaches. This work compares both calibration methods and shows the differences that can occur due to measurement uncertainty. This work presents the measured water content within the Inntal tunnel, Austria as a representative tunnel from a total of four investigated tunnels. The obtained water content is compared to that found in the literature, and recommendations for practical work in terms of fire safety is given. KW - tunnel inner lining KW - water content KW - moisture sensor KW - moisture measurement KW - Fire safety KW - concrete spalling Y1 - 2023 U6 - https://doi.org/10.2139/ssrn.4390700 ER -