TY - JOUR A1 - Wiesent, Lisa A1 - Schultheiß, Ulrich A1 - Lulla, Philipp A1 - Nonn, Aida A1 - Noster, Ulf T1 - Mechanical properties of small structures built by selective laser melting 316 L stainless steel – a phenomenological approach to improve component design JF - Materials Science & Engineering Technology JF - Materialwissenschaft und Werkstofftechnik N2 - Experimental investigations are conducted to quantify the influence of specimen thickness and orientation on the mechanical properties of selective laser melted stainless steel 316 L. The results indicate that the mechanical strength and ductility increase with increasing specimen thickness until a saturation value is reached from a specimen thickness of about 2 mm. Specimen orientation dependency is pronounced for thin specimens (<1.5 mm), whereas only small deviations in strength are observed for thicker specimens with orientations of 30°, 45° and 90° to build direction. The mechanical properties of the specimen orientation of 0° to build direction shows great deviation to the other orientations and the smallest overall strength. A reliable design of selective laser melted components should account for specimen thickness and orientation, e. g. by a correction factor. Furthermore, it is recommended to avoid loads vertical (90°) and parallel (0°) to build direction to guarantee higher ductility and strength. T2 - Mechanische Eigenschaften von kleinen Strukturen aus selektiv lasergeschmolzenem 316 L Edelstahl – ein phänomenologischer Ansatz zur Verbesserung des Bauteildesigns Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-14718 N1 - Corresponding author: Lisa Wiesent VL - 51 IS - 12 SP - 1615 EP - 1629 PB - Wiley ER - TY - JOUR A1 - Wiesent, Lisa A1 - Schultheiss, Ulrich A1 - Schmid, Christof A1 - Schratzenstaller, Thomas A1 - Nonn, Aida T1 - Experimentally validated simulation of coronary stents considering different dogboning ratios and asymmetric stent positioning JF - PlOS One N2 - In-stent restenosis remains a major problem of arteriosclerosis treatment by stenting. Expansion-optimized stents could reduce this problem. With numerical simulations, stent designs/ expansion behaviours can be effectively analyzed. For reasons of efficiency, simplified models of balloon-expandable stents are often used, but their accuracy must be challenged due to insufficient experimental validation. In this work, a realistic stent life-cycle simulation has been performed including balloon folding, stent crimping and free expansion of the balloon-stent-system. The successful simulation and validation of two stent designs with homogenous and heterogeneous stent stiffness and an asymmetrically positioned stent on the balloon catheter confirm the universal applicability of the simulation approach. Dogboning ratio, as well as the final dimensions of the folded balloon, the crimped and expanded stent, correspond well to the experimental dimensions with only slight deviations. In contrast to the detailed stent life-cycle simulation, a displacement-controlled simulation can not predict the transient stent expansion, but is suitable to reproduce the final expanded stent shape and the associated stress states. The detailed stent life-cycle simulation is thus essential for stent expansion analysis/optimization, whereas for reasons of computational efficiency, the displacement-controlled approach can be considered in the context of pure stress analysis. KW - Catheters KW - Coronary stenting KW - Deformation KW - Stent implantation KW - Stiffness KW - Stent KW - Ballondilatation KW - Numerische Strömungssimulation Y1 - 2019 U6 - https://doi.org/10.1371/journal.pone.0224026 VL - 14 IS - 10 SP - 1 EP - 25 PB - PLOS ER - TY - GEN A1 - Wiesent, Lisa A1 - Hupke, Constantin A1 - Balk, Christian A1 - Schultheiss, Ulrich A1 - Schratzenstaller, Thomas T1 - Optimization of the cardiovascular stent design towards improved expansion behaviour and radial stiffness properties T2 - Biomedizinische Technik N2 - - Development of a FEA Tool for a realistic stent simulation - investigation on minor modification on the stent design on the expansion behaviour - analysis of three stent designs: classical stent design with pronounced dogbone effect, two modified stent design (non-dogbone-design) KW - Kardiovaskuläres System KW - Stent Y1 - 2018 U6 - https://doi.org/10.1515/bmt-2018-6031 VL - 63 IS - s1 ER - TY - JOUR A1 - Wiesent, Lisa A1 - Schultheiß, Ulrich A1 - Lulla, Philipp A1 - Noster, Ulf A1 - Schratzenstaller, Thomas A1 - Schmid, Christof A1 - Nonn, Aida A1 - Spear, Ashley T1 - Computational analysis of the effects of geometric irregularities and post-processing steps on the mechanical behavior of additively manufactured 316L stainless steel stents JF - PLoS ONE N2 - Advances in additive manufacturing enable the production of tailored lattice structures and thus, in principle, coronary stents. This study investigates the effects of process-related irregularities, heat and surface treatment on the morphology, mechanical response, and expansion behavior of 316L stainless steel stents produced by laser powder bed fusion and provides a methodological approach for their numerical evaluation. A combined experimental and computational framework is used, based on both actual and computationally reconstructed laser powder bed fused stents. Process-related morphological deviations between the as-designed and actual laser powder bed fused stents were observed, resulting in a diameter increase by a factor of 2-2.6 for the stents without surface treatment and 1.3-2 for the electropolished stent compared to the as-designed stent. Thus, due to the increased geometrically induced stiffness, the laser powder bed fused stents in the as-built (7.11 ± 0.63 N) or the heat treated condition (5.87 ± 0.49 N) showed increased radial forces when compressed between two plates. After electropolishing, the heat treated stents exhibited radial forces (2.38 ± 0.23 N) comparable to conventional metallic stents. The laser powder bed fused stents were further affected by the size effect, resulting in a reduced yield strength by 41% in the as-built and by 59% in the heat treated condition compared to the bulk material obtained from tensile tests. The presented numerical approach was successful in predicting the macroscopic mechanical response of the stents under compression. During deformation, increased stiffness and local stress concentration were observed within the laser powder bed fused stents. Subsequent numerical expansion analysis of the derived stent models within a previously verified numerical model of stent expansion showed that electropolished and heat treated laser powder bed fused stents can exhibit comparable expansion behavior to conventional stents. The findings from this work motivate future experimental/numerical studies to quantify threshold values of critical geometric irregularities, which could be used to establish design guidelines for laser powder bed fused stents/lattice structures. KW - Heat treatment KW - Lasers KW - Surface treatments KW - Specimen preparation and treatment KW - Material properties KW - Stiffness KW - Deformation KW - Powders KW - Koronarendoprothese KW - Rapid prototyping KW - Numerische Methode Y1 - 2020 U6 - https://doi.org/10.1371/journal.pone.0244463 N1 - Corresponding author: Lisa Wiesent VL - 15 IS - 12 SP - 1 EP - 30 PB - PLOS ER -