TY - JOUR A1 - Schmidt, Thomas A1 - Kröger, Roland A1 - Flege, Jan Ingo A1 - Horn-von Hoegen, Michael A1 - Clausen, T. A1 - Falta, J. A1 - Janzen, Andreas A1 - Zahl, P. A1 - Kury, P. A1 - Kammler, Martin T1 - Less strain energy despite fewer misfit dislocations: the impact of ordering JF - Physical review letters N2 - The average strain state of Ge films grown on Si(111) by surfactant mediated epitaxy has been compared to the ordering of the interfacial misfit dislocation network. Surprisingly, a smaller degree of average lattice relaxation was found in films grown at higher temperature. On the other hand, these films exhibit a better ordered dislocation network. This effect energetically compensates the higher strain at higher growth temperature, leading to the conclusion that, apart from the formation of misfit dislocations, their ordering represents an important channel for lattice-strain energy relaxation. Y1 - 2006 U6 - https://doi.org/10.1103/PhysRevLett.96.066101 VL - 96 IS - 6 PB - APS ER - TY - JOUR A1 - Weber, Karsten A1 - Dendorfer, Sebastian A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Schratzenstaller, Thomas A1 - Haug, Sonja A1 - Mohr, Christa A1 - Kiesl, Hans A1 - Drechsler, Jörg A1 - Westner, Markus A1 - Kobus, Jörn A1 - Schubert, Martin J. W. A1 - Zenger, Stefan A1 - Pietsch, Alexander A1 - Weiß, Josef A1 - Hinterseer, Sebastian A1 - Schieck, Roland A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Ringlstetter, Andreas A1 - Störl, Uta A1 - Bissyandé, Tegawendé F. A1 - Seeburger, Achim A1 - Schindler, Timo A1 - Ramsauer, Ralf A1 - Kiszka, Jan A1 - Kölbl, Andreas A1 - Lohmann, Daniel A1 - Mauerer, Wolfgang A1 - Maier, Johannes A1 - Scorna, Ulrike A1 - Palm, Christoph A1 - Soska, Alexander A1 - Mottok, Jürgen A1 - Ellermeier, Andreas A1 - Vögele, Daniel A1 - Hierl, Stefan A1 - Briem, Ulrich A1 - Buschmann, Knut A1 - Ehrlich, Ingo A1 - Pongratz, Christian A1 - Pielmeier, Benjamin A1 - Tyroller, Quirin A1 - Monkman, Gareth J. A1 - Gut, Franz A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian A1 - Langer, Christoph A1 - Schreiner, Rupert A1 - Huang, Yifeng A1 - She, Juncong A1 - Ottl, Andreas A1 - Rieger, Walter A1 - Kraml, Agnes A1 - Poxleitner, Thomas A1 - Hofer, Simon A1 - Heisterkamp, Benjamin A1 - Lerch, Maximilian A1 - Sammer, Nike A1 - Golde, Olivia A1 - Wellnitz, Felix A1 - Schmid, Sandra A1 - Muntschick, Claudia A1 - Kusterle, Wolfgang A1 - Paric, Ivan A1 - Brückl, Oliver A1 - Haslbeck, Matthias A1 - Schmidt, Ottfried A1 - Schwanzer, Peter A1 - Rabl, Hans-Peter A1 - Sterner, Michael A1 - Bauer, Franz A1 - Steinmann, Sven A1 - Eckert, Fabian A1 - Hofrichter, Andreas ED - Baier, Wolfgang T1 - Forschungsbericht 2017 T3 - Forschungsberichte der OTH Regensburg - 2017 KW - Forschung KW - Forschungsbericht Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13835 SN - 978-3-9818209-3-5 CY - Regensburg ER - TY - JOUR A1 - Stichel, Thomas A1 - Frick, Thomas A1 - Laumer, Tobias A1 - Tenner, Felix A1 - Hausotte, Tino A1 - Merklein, Marion A1 - Schmidt, Michael T1 - A Round Robin study for Selective Laser Sintering of polyamide 12: Microstructural origin of the mechanical properties JF - Optics & Laser Technology N2 - The mechanical and microstructural investigation of polymer parts (polyamide 12) fabricated by Selective Laser Sintering as part of a Round Robin initiative is presented. The paper focuses on the microstructural analysis of the Round Robin samples and their evaluation regarding their effect on mechanical properties with respect to each other. Therefore optical microscopy on microtomed samples, X-ray computed tomography and Differential Scanning Calorimetry is used to determine the morphology of residual particle cores and of internal pores. Y1 - 2017 U6 - https://doi.org/10.1016/j.optlastec.2016.09.042 VL - 89 SP - 31 EP - 40 PB - Elsevier ER - TY - JOUR A1 - Launhardt, M. A1 - Wörz, A. A1 - Loderer, A. A1 - Laumer, Tobias A1 - Drummer, Dietmar A1 - Hausotte, Tino A1 - Schmidt, Michael T1 - Detecting surface roughness on SLS parts with various measuring techniques JF - Polymer Testing N2 - Selective Laser Sintering (SLS) is an additive manufacturing technique whereby a laser melts polymer powder layer by layer to generate three-dimensional parts. It enables the fabrication of parts with high degrees of complexity, nearly no geometrical restrictions, and without the necessity of a tool or a mold. Due to the orientation in the building space, the processing parameters, and the powder properties, the resulting parts possess an increased surface roughness. In comparison to other manufacturing techniques, e.g. injection molding, the surface roughness of SLS parts results from partially melted powder particles on the surface layer. The actual surface roughness must thus be characterized with respect to the part's eventual application. At the moment, there is no knowledge regarding which measuring technique is most suitable for detecting and quantifying SLS parts' surface roughness. The scope of this paper is to compare tactile profile measurement methods, as established in industry, to optical measurement techniques such as Focus Variation, Fringe Projection Technique (FPT), and Confocal Laser Scanning Microscope (CLSM). The advantages and disadvantages of each method are presented and, additionally, the effect of tactile measurement on a part's surface is investigated. KW - Selective Laser Sintering (SLS) KW - PA12 KW - Surface roughness KW - Measuring technique Y1 - 2016 SN - 0142-9418 U6 - https://doi.org/10.1016/j.polymertesting.2016.05.022 SN - 1873-2348 VL - 53 SP - 217 EP - 226 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hupfeld, T. A1 - Laumer, Tobias A1 - Stichel, T. A1 - Schuffenhauer, T. A1 - Heberle, J. A1 - Schmidt, Michael A1 - Barcikowski, S. A1 - Gökce, B. T1 - A new approach to coat PA12 powders with laser-generated nanoparticles for selective laser sintering JF - Procedia CIRP N2 - The modification of selective laser sintering (SLS) powder materials by nanoadditives offers the possibility to adapt the powder properties to the laser sintering process or the resulting part properties. To avoid agglomeration of the nanofiller, a new approach in which surfactant-free laser-generated colloidal nanoparticles are adsorbed onto the polymer surface directly in an aqueous solution is demonstrated. Based on this novel approach, polyamide 12 (PA12) powders are decorated with metal and oxide nanoparticles and processed via SLS. Electron microscopy and confocal laser scanning imaging are utilized to analyze the dispersion of the filler. KW - laser additive manufacturing KW - nanoparticles KW - polymer powders KW - pulsed laser ablation in liquids KW - selective laser sintering Y1 - 2018 U6 - https://doi.org/10.1016/j.procir.2018.08.103 VL - 74 SP - 244 EP - 248 PB - Elsevier ER - TY - JOUR A1 - Laumer, Tobias A1 - Stichel, T. A1 - Nagulin, K. A1 - Schmidt, Michael T1 - Optical analysis of polymer powder materials for Selective Laser Sintering JF - Polymer Testing N2 - This study increases the basic understanding of optical material properties of polymer powders used in selective laser sintering (SLS). Therefore, different polymer powder materials were analyzed regarding their optical material properties with an integration spheres measurement setup. By the measurements a direct connection between the absorption behavior of the solid material and the overall optical material characteristics of the same material in powdery form could be shown. The results were used to develop an advanced explanation model for the optical material properties of powders. At present, existing explanation models only consider the occurring of multiple reflections in the gaps between the particles to explain the overall optical material properties of powder materials. Thus, by also considering the absorption behavior of the single particles, the basic understanding of the beam-matter interaction and their effect on the optical material properties of powder materials can be expanded. KW - Additive manufacturing KW - Selective Laser Sintering KW - Optical material characteristics KW - Integration spheres KW - Material qualification KW - New materials Y1 - 2016 U6 - https://doi.org/10.1016/j.polymertesting.2016.10.010 SN - 1873-2348 SN - 0142-9418 VL - 56 SP - 207 EP - 213 PB - Elsevier Science CY - Amsterdam [u.a.] ER - TY - CHAP A1 - Laumer, Tobias A1 - Stichel, T. A1 - Sachs, Marius A1 - Amend, Philipp A1 - Schmidt, Michael ED - Bártolo, Paulo T1 - Qualification and modification of new polymer powders for laser beam melting using Ulbricht spheres T2 - High value manufacturing : Advanced research in virtual and rapid prototyping ; Proceedings of the 6th International Conference on Advanced Research and Rapid Prototyping, Leiraia, Portugal, 1-5 October, 2013 N2 - The restricted amount of available materials for Laser Beam Melting (LBM) of polymers is one of the main limitations for expanding the technology. Current qualification methods deal with problems like inadequate powder flowability or high part porosities among others but do not offer a detailed analysis of the important beam-matter-interaction between powder particles and electro-magnetic laser radiation. In this paper, polyethylene powder is qualified for the LBM process and specifically analyzed regarding the optical material properties of the powder for a wavelength of 10.6 μm. By admixing graphite as absorption intensifier the change of the optical material properties and the thereby connected processing parameters are analyzed. Furthermore an explanation approach is given to explain the relation between different transmittances of different powder particles and the optical material properties of the polymer powders. Y1 - 2014 UR - https://www.researchgate.net/publication/286311000_Qualification_and_modification_of_new_polymer_powders_for_laser_beam_melting_using_Ulbricht_spheres SN - 978-1-138-00137-4 SN - 1138001376 SP - 255 EP - 260 PB - CRC Press CY - Boca Raton ER - TY - JOUR A1 - Klein, C. A1 - Nabbefeld, T. A1 - Hattab, H. A1 - Meyer, D. A1 - Jnawali, G. A1 - Kammler, Martin A1 - Meyer zu Heringdorf, Frank-Joachim A1 - Golla-Franz, A. A1 - Müller, B. H. A1 - Schmidt, Thomas A1 - Henzler, M. A1 - Horn-von Hoegen, Michael T1 - Lost in reciprocal space? Determination of the scattering condition in spot profile analysis low-energy electron diffraction JF - Review of scientific instruments N2 - The precise knowledge of the diffraction condition, i.e., the angle of incidence and electron energy, is crucial for the study of surface morphology through spot profile analysis low-energy electron diffraction (LEED). We demonstrate four different procedures to determine the diffraction condition: employing the distortion of the LEED pattern under large angles of incidence, the layer-by-layer growth oscillations during homoepitaxial growth, a G(S) analysis of a rough surface, and the intersection of facet rods with 3D Bragg conditions. Y1 - 2011 U6 - https://doi.org/10.1063/1.3554305 VL - 82 IS - 3 PB - American Institute of Physics ER - TY - JOUR A1 - Schmidt, Thomas A1 - Kröger, Roland A1 - Clausen, T. A1 - Falta, J. A1 - Janzen, Andreas A1 - Kammler, Martin A1 - Kury, P. A1 - Zahl, P. A1 - Horn-von Hoegen, Michael T1 - Surfactant-mediated epitaxy of Ge on Si(111): Beyond the surface JF - Applied Physics Letters N2 - For a characterization of interface and “bulk” properties of Ge films grown on Si(111) by Sb surfactant-mediated epitaxy, grazing incidence x-ray diffraction and transmission electron microscopy have been used. The interface roughness, defect structure, and strain state have been investigated in dependence of film thickness and growth temperature. For all growth parameters, atomically smooth interfaces are observed. For thin Ge layers, about 75% of the strain induced by the lattice mismatch is relaxed by misfit dislocations at the Ge/Si interface. Only a slight increase of the degree of relaxation is found for thicker films. At growth temperatures below about 600 °C, the formation of twins is observed, which can be avoided at higher temperatures. Y1 - 2005 U6 - https://doi.org/10.1063/1.1882760 VL - 86 IS - 11 PB - AIP ER - TY - JOUR A1 - Frigge, Tim A1 - Wall, S. A1 - Krenzer, Boris A1 - Wippermann, St. A1 - Sanna, Simone A1 - Klasing, Friedrich A1 - Hanisch-Blicharski, Anja A1 - Kammler, Martin A1 - Schmidt, Wolf Gero A1 - Horn-von Hoegen, Michael T1 - Abstract - A Reply to the Comment by H. Shim et al. JF - Physical review letters Y1 - 2013 U6 - https://doi.org/10.1103/PhysRevLett.111.149602 VL - 111 IS - 14 PB - American Physical Society ER - TY - JOUR A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Muzalyova, Anna A1 - Rauber, David A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Yip, Hon Chi A1 - Lau, Louis Ho Shing A1 - Gölder, Stefan Karl A1 - Schmidt, Arthur A1 - Kouladouros, Konstantinos A1 - Abdelhafez, Mohamed A1 - Walter, Benjamin M. A1 - Meinikheim, Michael A1 - Chiu, Philip Wai Yan A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Artificial intelligence improves submucosal vessel detection during third space endoscopy JF - Endoscopy N2 - Background and study aims: While artificial intelligence (AI) shows high potential in decision support for diagnostic gastrointestinal endoscopy, its role in therapeutic endoscopy remains unclear. Third space endoscopic procedures pose the risk of intraprocedural bleeding. Therefore, we aimed to develop an AI algorithm for intraprocedural blood vessel detection. Patients and Methods: Using a test dataset with 101 standardized video clips containing 200 predefined submucosal blood vessels, 19 endoscopists were evaluated for the vessel detection rate (VDR) and time (VDT) with and without support of an AI algorithm. Test subjects were grouped according to experience in ESD. Results: With AI support, endoscopists VDR increased from 56.4% [CI 54.1–58.6] to 72.4% [CI 70.3–74.4]. Endoscopists‘ VDT dropped from 6.7sec [CI 6.2-7.1] to 5.2sec [CI 4.8-5.7]. False positive (FP) readings appeared in 4.5% of frames and were marked significantly shorter than true positives (6.0sec [CI 5.28-6.70] vs. 0.7sec [CI 0.55-0.87]). Conclusions: AI improved the vessel detection rate and time of endoscopists during third space endoscopy. While these data need to be corroborated by clinical trials, AI may prove to be an invaluable tool for the improvement of endoscopic interventions. KW - Artificial Intelligence KW - Third Space Endoscopy Y1 - 2025 U6 - https://doi.org/10.1055/a-2534-1164 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Muzalyova, Anna A1 - Rauber, David A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Yip, Hon Chi A1 - Lau, Louis Ho Shing A1 - Gölder, Stefan Karl A1 - Schmidt, Arthur A1 - Kouladouros, Konstantinos A1 - Abdelhafez, Mohamed A1 - Walter, B. A1 - Meinikheim, Michael A1 - Chiu, Philip Wai Yan A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Künstliche Intelligenz erhöht die Gefäßerkennung von Endoskopikern bei third space Endoskopie T2 - Zeitschrift für Gastroenterologie N2 - Einleitung: Künstliche Intelligenz (KI)-Algorithmen unterstützen Endoskopiker bei der Erkennung und Charakterisierung von Kolonpolypen in der klinischen Praxis und führen zu einer Erhöhung der Adenomdetektionsrate. Auch bei therapeutischen Maßnahmen wie der endoskopischen Submukosadissektion (ESD) könne relevante anatomische Strukturen durch KI mit hoher Genauigkeit erkannt und im endoskopischen Bild in Echtzeit markiert werden. Der Effekt einer solchen Applikation auf die Gefäßdetektion von Endoskopikern ist bislang nicht erforscht. Ziele:  In dieser Studie wurde der Effekt eines KI-Algorithmus zur Echtzeit-Gefäßmarkierung bei ESD auf die Gefäßdetektionsrate von Endoskopikern untersucht. Methodik:  59 third space Endoskopievideos wurde aus der Datenbank des Universitätsklinikums Augsburg extrahiert. Auf 5470 Einzelbildern dieser Untersuchungen wurde submukosale Blutgefäße annotiert. Zusammen mit weiteren 179681 unmarkierten Bildern wurde ein DeepLabV3+ neuronales Netzwerk mit einer semi-supervised learning Methode darin trainiert, submukosale Blutgefäße auf dem endoskopischen Bild zu erkennen und in Echtzeit einzuzeichnen. Anhand eines Videotests mit 101 Videoclips und 200 vordefinierten Blutgefäßen wurden 19 Endoskopiker mit und ohne KI Unterstützung getestet. Ergebnis:  Der Algorithmus erkannte in dem Videotest 93.5% der Gefäße in einer Detektionszeit von im Median 0,3 Sekunden. Die Gefäßdetektionsrate von Endoskopikern erhöhte sich durch KI Unterstützung von 56,4% auf 72,4% (p<0.001). Die Gefäßdetektionszeit reduzierte sich durch KI-Unterstützung von 6,7 auf 5.2 Sekunden (p<0.001). Der Algorithmus zeigte eine Rate an falsch positiven Detektionen in 4.5% der Einzelbilder. Falsch positiv erkannte Strukturen wurde kürzer detektiert, als richtig positive (0.7 und 6.0 Sekunden, p<0.001). Schlussfolgerung:  KI Unterstützung führte zu einer erhöhten Gefäßdetektionsrate und schnelleren Gefäßdetektionszeit von Endoskopikern. Ein möglicher klinischer Effekt auf die intraprozedurale Komplikationsrate oder Operationszeit könnte in prospektiven Studien ermittelt werden. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1790087 VL - 62 IS - 09 SP - e830 PB - Georg Thieme Verlag KG ER -