TY - JOUR A1 - Diermeier, Andreas A1 - Sindersberger, Dirk A1 - Angele, Peter A1 - Kujat, Richard A1 - Monkman, Gareth J. T1 - Sensor system for use with low intensity pulsed ultrasound JF - Sensor review N2 - Purpose Ultrasound is a well-established technology in medical science, though many of the conventional measurement systems (hydrophones and radiation force balances [RFBs]) often lack accuracy and tend to be expensive. This is a significant problem where sensors must be considered to be "disposable" because they inevitably come into contact with biological fluids and expense increases dramatically in cases where a large number of sensors in array form are required. This is inevitably the case where ultrasound is to be used for the in vitro growth stimulation of a large plurality of biological samples in tissue engineering. Traditionally only a single excitation frequency is used (typically 1.5 MHz), but future research demands a larger choice of wavelengths for which a single broadband measurement transducer is desirable. Furthermore, because of implementation conditions there can also be large discrepancies between measurements. The purpose of this paper deals with a very cost-effective alternative to expensive RFBs and hydrophones. Design/methodology/approach Utilization of cost-effective piezoelectric elements as broadband sensors. Findings Very effective results with equivalent (if not better) accuracy than expensive alternatives. Originality/value This paper concentrates on how very cost-effective piezoelectric ultrasound transducers can be implemented as sensors for ultrasound power measurements with accuracy as good, if not better than those achievable using radiation force balances or hydrophones. KW - BALANCE KW - Hydrophone KW - Mesenchymal stem cell KW - Piezoelectric transducer KW - Radiation force balance KW - Sensors KW - therapy KW - Tissue engineering KW - Ultrasound Y1 - 2019 U6 - https://doi.org/10.1108/SR-11-2018-0304 SN - 0260-2288 VL - 39 IS - 6 SP - 828 EP - 834 PB - Emerald ER - TY - JOUR A1 - Huber, Michaela A1 - Schlosser, Daniela A1 - Stenzel, Susanne A1 - Maier, Johannes A1 - Pattappa, Girish A1 - Kujat, Richard A1 - Striegl, Birgit A1 - Docheva, Denitsa T1 - Quantitative Analysis of Surface Contouring with Pulsed Bipolar Radiofrequency on Thin Chondromalacic Cartilage JF - BioMed Research International N2 - The purpose of this study was to evaluate the quality of surface contouring of chondromalacic cartilage by bipolar radio frequency energy using different treatment patterns in an animal model, as well as examining the impact of the treatment onto chondrocyte viability by two different methods. Our experiments were conducted on 36 fresh osteochondral sections from the tibia plateau of slaughtered 6-month-old pigs, where the thickness of the cartilage is similar to that of human wrist cartilage. An area of 1 cm(2) was first treated with emery paper to simulate the chondromalacic cartilage. Then, the treatment with RFE followed in 6 different patterns. The osteochondral sections were assessed for cellular viability (live/dead assay, caspase (cell apoptosis marker) staining, and quantitative analysed images obtained by fluorescent microscopy). For a quantitative characterization of none or treated cartilage surfaces, various roughness parameters were measured using confocal laser scanning microscopy (Olympus LEXT OLS 4000 3D). To describe the roughness, the Root-Mean-Square parameter (Sq) was calculated. A smoothing effect of the cartilage surface was detectable upon each pattern of RFE treatment. The Sq for native cartilage was Sq=3.8 +/- 1.1 mu m. The best smoothing pattern was seen for two RFE passes and a 2-second pulsed mode (B2p2) with an Sq=27.3 +/- 4.9 mu m. However, with increased smoothing, an augmentation in chondrocyte death up to 95% was detected. Using bipolar RFE treatment in arthroscopy for small joints like the wrist or MCP joints should be used with caution. In the case of chondroplasty, there is a high chance to destroy the joint cartilage. KW - CHONDROCYTE DEATH KW - energy KW - HUMAN ARTICULAR-CARTILAGE KW - MONOPOLAR KW - THERMAL CHONDROPLASTY Y1 - 2020 U6 - https://doi.org/10.1155/2020/1242086 SP - 1 EP - 8 PB - HINDAWI ER - TY - JOUR A1 - Zellner, Johannes A1 - Hierl, Katja A1 - Mueller, Michael A1 - Pfeifer, Christian A1 - Berner, Arne A1 - Dienstknecht, Thomas A1 - Krutsch, Werner A1 - Geis, Sebastian A1 - Gehmert, Sebastian A1 - Kujat, Richard A1 - Dendorfer, Sebastian A1 - Prantl, Lukas A1 - Nerlich, Michael A1 - Angele, Peter ED - Gilbert, Jeremy T1 - Stem cell-based tissue-engineering for treatment of meniscal tears in the avascular zone JF - Journal of Biomedical Materials Research Part B Applied Biomaterials N2 - Meniscal tears in the avascular zone have a poor self-healing potential, however partial meniscectomy predisposes the knee for early osteoarthritis. Tissue engineering with mesenchymal stem cells and a hyaluronan collagen based scaffold is a promising approach to repair meniscal tears in the avascular zone. 4 mm longitudinal meniscal tears in the avascular zone of lateral menisci of New Zealand White Rabbits were performed. The defect was left empty, sutured with a 5-0 suture or filled with a hyaluronan/collagen composite matrix without cells, with platelet rich plasma or with autologous mesenchymal stem cells. Matrices with stem cells were in part precultured in chondrogenic medium for 14 days prior to the implantation. Menisci were harvested at 6 and 12 weeks. The developed repair tissue was analyzed macroscopically, histologically and biomechanically. Untreated defects, defects treated with suture alone, with cell-free or with platelet rich plasma seeded implants showed a muted fibrous healing response. The implantation of stem cell-matrix constructs initiated fibrocartilage-like repair tissue, with better integration and biomechanical properties in the precultured stem cell-matrix group. A hyaluronan-collagen based composite scaffold seeded with mesenchymal stem cells is more effective in the repair avascular meniscal tear with stable meniscus-like tissue and to restore the native meniscus. KW - biomechanics KW - meniscus KW - scaffolds KW - stem cells KW - tissue engineering KW - Meniskusschaden KW - Tissue Engineering KW - Mesenchymzelle KW - Hyaluronsäure Y1 - 2013 U6 - https://doi.org/10.1002/jbm.b.32922 VL - 101 IS - 7 SP - 1133 EP - 1142 ER - TY - CHAP A1 - Penzkofer, Rainer A1 - Grechenig, S. A1 - Kujat, Richard A1 - Angele, Peter A1 - Dendorfer, Sebastian T1 - Biomechanical comparison of the dorsal femur condyles and the iliac crest in terms of failure behavior T2 - XXV Congress of the International Society of Biomechanics, Glasgow, UK, 12th-16th July 2015 Y1 - 2015 ER - TY - CHAP A1 - Striegl, B. A1 - Kujat, Richard A1 - Dendorfer, Sebastian T1 - Quantitative analysis of cartilage surface by confocal laser scanning microscopy T2 - Biomedizinische Technik Y1 - 2014 U6 - https://doi.org/10.1515/bmt-2014-4012 VL - 59 IS - s1-A SP - 24 ER - TY - JOUR A1 - Beimler, Josef A1 - Leißl, Caroline A1 - Ebner, Lena A1 - Elsner, Michael A1 - Mühlbauer, Gerhard A1 - Kohlert, Dieter A1 - Schubert, Martin J. W. A1 - Weiß, Andreas P. A1 - Sterner, Michael A1 - Raith, Thomas A1 - Afranseder, Martin A1 - Krapf, Tobias A1 - Mottok, Jürgen A1 - Siemers, Christian A1 - Großmann, Benjamin A1 - Höcherl, Johannes A1 - Schlegl, Thomas A1 - Schneider, Ralph A1 - Milaev, Johannes A1 - Rampelt, Christina A1 - Roduner, Christian A1 - Glowa, Christoph A1 - Bachl, Christoph A1 - Schliekmann, Claus A1 - Gnan, Alfons A1 - Grill, Martin A1 - Ruhland, Karl A1 - Piehler, Thomas A1 - Friers, Daniel A1 - Wels, Harald A1 - Pflug, Kenny A1 - Kucera, Markus A1 - Waas, Thomas A1 - Schlachetzki, Felix A1 - Boy, Sandra A1 - Pemmerl, Josef A1 - Leis, Alexander A1 - Welsch, Andreas F.X. A1 - Graf, Franz A1 - Zenger, Gerhard A1 - Volbert, Klaus A1 - Waas, Thomas A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Störl, Uta A1 - Heyl, C. A1 - Boldenko, A. A1 - Monkman, Gareth J. A1 - Kujat, Richard A1 - Briem, Ulrich A1 - Hierl, Stefan A1 - Talbot, Sebastian A1 - Schmailzl, Anton A1 - Ławrowski, Robert Damian A1 - Prommesberger, Christian A1 - Langer, Christoph A1 - Dams, Florian A1 - Schreiner, Rupert A1 - Valentino, Piergiorgio A1 - Romano, Marco A1 - Ehrlich, Ingo A1 - Furgiuele, Franco A1 - Gebbeken, Norbert A1 - Eisenried, Michael A1 - Jungbauer, Bastian A1 - Hutterer, Albert A1 - Bauhuber, Michael A1 - Mikrievskij, Andreas A1 - Argauer, Monika A1 - Hummel, Helmut A1 - Lechner, Alfred A1 - Liebetruth, Thomas A1 - Schumm, Michael A1 - Joseph, Saskia A1 - Reschke, Michael A1 - Soska, Alexander A1 - Schroll-Decker, Irmgard A1 - Putzer, Michael A1 - Rasmussen, John A1 - Dendorfer, Sebastian A1 - Weber, Tim A1 - Al-Munajjed, Amir Andreas A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias A1 - Haug, Sonja A1 - Rudolph, Clarissa A1 - Zeitler, Annika A1 - Schaubeck, Simon A1 - Steffens, Oliver A1 - Rechenauer, Christian A1 - Schulz-Brize, Thekla A1 - Fleischmann, Florian A1 - Kusterle, Wolfgang A1 - Beer, Anne A1 - Wagner, Bernd A1 - Neidhart, Thomas ED - Baier, Wolfgang T1 - Forschungsbericht 2013 T3 - Forschungsberichte der OTH Regensburg - 2013 Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-7990 CY - Regensburg ER -