TY - JOUR A1 - Weber, Karsten A1 - Dendorfer, Sebastian A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Schratzenstaller, Thomas A1 - Haug, Sonja A1 - Mohr, Christa A1 - Kiesl, Hans A1 - Drechsler, Jörg A1 - Westner, Markus A1 - Kobus, Jörn A1 - Schubert, Martin J. W. A1 - Zenger, Stefan A1 - Pietsch, Alexander A1 - Weiß, Josef A1 - Hinterseer, Sebastian A1 - Schieck, Roland A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Ringlstetter, Andreas A1 - Störl, Uta A1 - Bissyandé, Tegawendé F. A1 - Seeburger, Achim A1 - Schindler, Timo A1 - Ramsauer, Ralf A1 - Kiszka, Jan A1 - Kölbl, Andreas A1 - Lohmann, Daniel A1 - Mauerer, Wolfgang A1 - Maier, Johannes A1 - Scorna, Ulrike A1 - Palm, Christoph A1 - Soska, Alexander A1 - Mottok, Jürgen A1 - Ellermeier, Andreas A1 - Vögele, Daniel A1 - Hierl, Stefan A1 - Briem, Ulrich A1 - Buschmann, Knut A1 - Ehrlich, Ingo A1 - Pongratz, Christian A1 - Pielmeier, Benjamin A1 - Tyroller, Quirin A1 - Monkman, Gareth J. A1 - Gut, Franz A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian A1 - Langer, Christoph A1 - Schreiner, Rupert A1 - Huang, Yifeng A1 - She, Juncong A1 - Ottl, Andreas A1 - Rieger, Walter A1 - Kraml, Agnes A1 - Poxleitner, Thomas A1 - Hofer, Simon A1 - Heisterkamp, Benjamin A1 - Lerch, Maximilian A1 - Sammer, Nike A1 - Golde, Olivia A1 - Wellnitz, Felix A1 - Schmid, Sandra A1 - Muntschick, Claudia A1 - Kusterle, Wolfgang A1 - Paric, Ivan A1 - Brückl, Oliver A1 - Haslbeck, Matthias A1 - Schmidt, Ottfried A1 - Schwanzer, Peter A1 - Rabl, Hans-Peter A1 - Sterner, Michael A1 - Bauer, Franz A1 - Steinmann, Sven A1 - Eckert, Fabian A1 - Hofrichter, Andreas ED - Baier, Wolfgang T1 - Forschungsbericht 2017 T3 - Forschungsberichte der OTH Regensburg - 2017 KW - Forschung KW - Forschungsbericht Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13835 SN - 978-3-9818209-3-5 CY - Regensburg ER - TY - JOUR A1 - Hausler, Peter A1 - Holzner, Lukas A1 - Ehrnsperger, Matthias A1 - Bierl, Rudolf T1 - Evaluation of the creep strength of samples produced by fused deposition modeling JF - Open Engineering N2 - Data sheets for 3D printing materials typically include softening temperature, impact strength, tensile strength, and stiffness. However, creep strength, an important parameter for components used over an extended period, is usually not included. Nevertheless, this parameter is of significant importance for components that are used over an extended period of time.This study compares the long-term creep behavior of a selection of materials that are commonly used in fused deposition modeling 3D printing. The materials under investigation are acrylonitrile butadiene styrene, acrylonitrile styrene acrylate, polylactic acid, and polycarbonate. In addition, the influence of fiber reinforcements on these materials is also examined. A simple, reproducible test procedure is proposed for users to determine and compare creep resistance of materials. This enables developers to select materials suitable for their own requirements on creep resistance and allows 3D-printing users to compare different materials. Results suggest that fiber reinforcement generally improves creep stability in 3D-printing materials, with GreenTEC Pro Carbon and add:north PC Blend HT LCF showing the most promise in this study. Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-79760 N1 - Corresponding author der OTH Regensburg: Peter Hausler VL - 14 IS - 1 PB - de Gruyter ER - TY - CHAP A1 - Hausler, Peter A1 - Jobst, Simon A1 - Fischer, Johannes A1 - Roth, Carina A1 - Bierl, Rudolf T1 - Homogeneous Light Source for Surface Plasmon Resonance Imaging T2 - PHOTOPTICS 2020: proceedings of the 8th International Conference on Photonics, Optics and Laser Technology, Valletta, Malta, February 27-29, 2020 N2 - We describe how to build a homogeneous light source for Surface Plasmon Resonance Imaging (SPRi) which mainly finds its applications in pharmaceutical screening and biotechnology so far. SPR spectroscopy is a label-free, non-destructive and highly sensitive measurement principle for detecting changes in the refractive index in close vicinity of a gold surface. A transfer of this technology to a miniaturized sensor will broaden the range of possible applications. Commercial SPR assays are mainly working with a small number of sensing spots. In contrast, the SPR imaging system shown here will allow the use of an array of many sensing spots. In combination with chemical receptors designed as an artificial nose or an electronic tongue, the simultaneous detection of many analytes is envisioned. So far, lasers or other inhomogeneous light sources were used to illuminate the sensing surface, which is decreasing the systems sensitivity. We show a compact ( 300mm2) homogeneous top hat profile. The combination of a high bit-resolution camera with our new light source enables a reflectivity based surface plasmon resonance imaging system with a high refractive index unit (RIU) resolution. KW - Surface Plasmon Resonance Spectroscopy KW - Sensor KW - SPR-imaging KW - Miniaturization KW - Micro-opto-electro-mechanical Systems Y1 - 2020 U6 - https://doi.org/10.5220/0009168701630167 SP - 163 EP - 167 PB - SCITEPRESS - Science and Technology Publications ER - TY - CHAP A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf T1 - Einbindung eines 2D-Photodetektors in einen hochintegrierten SPR-Imaging-Sensor T2 - 118. Jahrestagung der deutschen Gesellschaft für angewandte Optik (DGaO), 6.-10. Juni 2017, Dresden N2 - Mit der Oberflächenplasmonenresonanzspektroskopie (SPR) können Brechungsindexänderungen eines Analyten von bis zu 10-6 RIU detektiert werden. Das SPR-Imaging bietet heute gegenüber der konventionellen SPR-Analyse die Möglichkeit, mehrere einzelne Messungen parallel durchführen zu können. Mit Hilfe eines zweidimensionalen Sensorchips und einer leistungsfähigen Boardlevelkamera können die Abbildungen des Chips direkt an einen Rechner übertragen und dort verarbeitet werden. Aufgrund unterschiedlicher Winkelstellungen und der Geometrie des Aufbaus entstehen Stauchungen und Streckungen des abgebildeten Sensorchips, die mit verschiedenen Ansätzen aus der Bildverarbeitung ausgeglichen werden, um die Bilder miteinander vergleichen zu können. Zudem wird die Güte der Referenz- und Messbereiche des Chips bestimmt. Diese Algorithmen sind nur möglich aufgrund der heutigen, leistungsfähigen Rechner und der immer größer werdenden Durchsatzraten der Kameras. Dabei kommt in dieser Anwendung der relativ neue Kamerastandard USB3 Vision zum Einsatz. Dieser zeichnet sich zusätzlich durch das Plug and Play und seinen Standardstecker, der an (fast) jedem Rechner vorhanden ist, aus. KW - Bildverarbeitung KW - Messtechnik KW - Optische Informationsverarbeitung Y1 - 2017 ER - TY - GEN A1 - Hausler, Peter A1 - Roth, Carina A1 - Vitzthumecker, Thomas A1 - Fischer, Johannes A1 - Bierl, Rudolf T1 - Motionless SPR-angle scan with a miniaturized device T2 - Europtrode XIV, Naples, 25-28 March 2018 Y1 - 2018 ER - TY - CHAP A1 - Holler, Sven A1 - Hausler, Peter A1 - Roth, Carina A1 - Bierl, Rudolf T1 - Gestapelte Au-Al-Au und Au-Ag-Au Schichten als aktive Schichten für die Oberflächenplasmonenresonanzspektroskopie T2 - 5. Landshuter Symposium Mikrosystemtechnik, März 2016 Y1 - 2016 SN - 978-3-9812696-9-7 SP - 192 EP - 198 PB - Fachhochschule Landshut CY - Landshut ER - TY - CHAP A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf T1 - Einbindung eines CMOS-Detektors in einen hochintegrierten SPR-Sensor T2 - 5. Landshuter Symposium Mikrosystemtechnik, März 2016 Y1 - 2016 SN - 78-3-9812696-9-7 SP - 200 EP - 205 PB - Fachhochschule Landshut CY - Landshut ER - TY - JOUR A1 - Wunderlich, Lukas A1 - Hausler, Peter A1 - Maerkl, Susanne A1 - Bierl, Rudolf A1 - Hirsch, Thomas T1 - Nanoparticle Determination in Water by LED-Excited Surface Plasmon Resonance Imaging JF - Chemosensors N2 - The increasing popularity of nanoparticles in many applications has led to the fact that these persistent materials pollute our environment and threaten our health. An online sensor system for monitoring the presence of nanoparticles in fresh water would be highly desired. We propose a label-free sensor based on SPR imaging. The sensitivity was enhanced by a factor of about 100 by improving the detector by using a high-resolution camera. This revealed that the light source also needed to be improved by using LED excitation instead of a laser light source. As a receptor, different self-assembled monolayers have been screened. It can be seen that the nanoparticle receptor interaction is of a complex nature. The best system when taking sensitivity as well as reversibility into account is given by a dodecanethiol monolayer on the gold sensor surface. Lanthanide-doped nanoparticles, 29 nm in diameter and with a similar refractive index to the most common silica nanoparticles were detected in water down to 1.5 mu g mL(-1). The sensor can be fully regenerated within one hour without the need for any washing buffer. This sensing concept is expected to be easily adapted for the detection of nanoparticles of different size, shape, and composition, and upon miniaturization, suitable for long-term applications to monitor the quality of water. KW - ENGINEERED NANOPARTICLES KW - imaging KW - nanoparticle KW - plasmon resonance KW - REFRACTIVE-INDEX KW - sensor KW - surface Y1 - 2021 U6 - https://doi.org/10.3390/chemosensors9070175 SN - 2227-9040 VL - 9 IS - 7 SP - 1 EP - 9 PB - MDPI ER - TY - CHAP A1 - Hausler, Peter A1 - Roth, Carina A1 - Vitzthumecker, Thomas A1 - Bierl, Rudolf ED - Ribeiro, Paulo ED - Raposo, Maria T1 - Miniaturized Surface Plasmon Resonance Based Sensor Systems BT - Opportunities and Challenges T2 - Optics, Photonics and Laser Technology 2018 N2 - Surface Plasmon Resonance (SPR) is a well-known and established technology in bioanalysis and pharmaceutical sciences. Due to the expensive instrumentation and the need of trained people, it is mainly limited to applications in laboratories. However, there are some areas like environmental monitoring, chemical processing and civil infrastructure, which urgently need new sensor technologies. SPR has the potential to serve these fields. In order to be qualified for a use in these areas SPR has to overcome some hurdles. The instrumentation has to be robust, small in size and cheap. A device, which fits these needs, will be a micro-opto-electro-mechanical system (MOEMS) with integrated intelligent algorithms. In this book chapter, examples of miniaturized SPR devices are introduced, the limitations which have to be overcome as well as the possibilities for future applications are proposed. Due to the manifold advantages of this technology and the dropping prices for imaging sensors, Surface Plasmon Resonance imaging (SPRi) might become one of the leading technologies for SPR smart sensor systems. Y1 - 2019 SN - 978-3-030-30112-5 U6 - https://doi.org/10.1007/978-3-030-30113-2_8 SP - 169 EP - 195 PB - Springer Nature CY - Cham ER - TY - CHAP A1 - Hausler, Peter A1 - Wunderlich, Lukas A1 - Fischer, Johannes A1 - Pfab, Christina A1 - Heckscher, Simon A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Surface plasmon resonance imaging for detection of drug metabolites in water T2 - Proceedings of SPIE, Optical Sensors 2019, 1 - 4 April 2019, Prague, Czech Republic N2 - The analysis of surface water, groundwater, drinking water as well as sewage is important to get information about the contamination of the water cycle. Currently, these time-consuming investigations require special equipment, like for example hyphenated mass spectrometry. Surface plasmon resonance (SPR) is a faster alternative as it is highly sensitive to changes in the dielectric medium next to a thin metal layer and makes it a quasi-universal detector. Therefore, and due to the labelfree nature, SPR is a widely used sensing tool for real‐time monitoring of molecular interactions of various analytes. SPR imaging (SPRi) has several advantages to standard surface plasmon resonance, as it allows to observe many analytes in parallel as well as the integration of referencing technologies. However, the homogenous illumination of a large area (several millimeters) with a small light source is challenging and demands new approaches. Allopurinol, a drug used to lower the blood concentration of urate and hence decrease the affection of gout, gets metabolized to oxipurinol in the body and dropped out almost entirely by urinary excretion. After wastewater treatment, concentrations of oxipurinol up to 21.7 μg•L-1 are detected. Further tracking of oxipurinol in the urban water cycle showed its presence in rivers and streams or even in groundwater. Therefore, the high biological stability of oxipurinol allows this molecule to be used as a marker for domestic wastewater in the environment. For the detection of oxipurinol by SPR graphene was used as receptive layer, as the analyte can bind via π-stacking to this surface. An SPRi technique was developed and compared to conventional SPR system for the detection of oxipurinol. Y1 - 2019 U6 - https://doi.org/10.1117/12.2522324 SN - 0277-786X VL - Vol. 11028 ER - TY - CHAP A1 - Hausler, Peter A1 - Roth, Carina A1 - Aumer, F. A1 - Vitzthumecker, Thomas A1 - Genslein, Christa A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Miniaturisiertes Sensorsystem zur Oberflächenplasmonenresonanzspektroskopie T2 - 118. Jahrestagung der deutschen Gesellschaft für angewandte Optik (DGaO), 6.-10. Juni 2017, Dresden N2 - Die Oberflächenplasmonenresonanzspektroskopie (SPR) wird aufgrund ihrer Vorzüge der zerstörungs- und markierungsfreien Messung, sowie der hohen Sensitivität sehr erfolgreich im Labormaßstab eingesetzt. Aufgrund der hohen Kosten geschieht dies bislang hauptsächlich in der Bioanalytik und dem Wirkstoffscreening. Gezeigt wird ein Ansatz, mit dem diese Technologie auf ein ultrakompaktes, kostengünstiges Sensorsystem übertragen wird, welches in der Lage ist, hoch-sensitiv Änderungen im Brechungsindex von 10-6 Einheiten (RIU) zu detektieren. Für Wasser bewirkt eine Temperaturschwankung von 1 K bereits eine Änderung von 1 mRIU. Daher wird durch ein integriertes Referenzsystem, sowie die Miniaturisierung erreicht, dass das System gegenüber Temperaturschwankungen, weitestgehend stabil ist. In dem MOEMS wird anstatt der konventionellen 1-Punkt bzw. 2-Punkt Messung ein bildgebendes Verfahren angewendet. Die Sensorfläche von 15 x 15 mm wird dabei mit einem handelsüblichen 4 Mio. Pixel CMOS Sensor ausgewertet. Um verlässliche Datenpunkte zu erhalten benötigt man eine Fläche von 10 x 10 Pixel. Demzufolge können auf dem Sensor theoretisch bis zu 40.000 Sensorspots parallel ausgewertet werden. KW - Messtechnik KW - Optische Systeme KW - Spektroskopie Y1 - 2017 ER - TY - CHAP A1 - Hausler, Peter A1 - Genslein, Christa A1 - Roth, Carina A1 - Vitzthumecker, Thomas A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Miniaturized Surface Plasmon Resonance based Sensor System T2 - Proceedings of the 6th International Conference on Photonics, Optics and Laser Technology - PHOTOPTICS, Funchal, Madeira, Portugal N2 - We describe the miniaturization of the Surface Plasmon Resonance (SPR) technology which mainly finds its applications in pharmaceutical screening and biotechnology so far. SPR spectroscopy is a label-free, non-destructive and highly sensitive measurement principle detecting changes in the refractive index in striking distance to a gold surface. A transfer of this technology to a miniaturized sensor will broaden the range of possible applications. A promising feature which is included in the miniaturized system is the angle-dependent recording of the SPR signals without moving parts. Commercial SPR assays are mainly working with a small number of sensing spots. In contrast, the SPR imaging system shown here will allow to use an array of many sensing spots. In combination with chemical receptors designed as an artificial nose, the simultaneous detection of many analytes is envisioned for future applications. KW - Surface Plasmon Resonance Spectroscopy KW - Sensor KW - SPR-imaging KW - Miniaturization KW - Micro-Opto-Electro-Mechanical Systems Y1 - 2018 SN - 978-989-758-286-8 U6 - https://doi.org/10.5220/0006555400630066 SP - 63 EP - 66 PB - SciTePress ER - TY - JOUR A1 - Genslein, Christa A1 - Hausler, Peter A1 - Kirchner, Eva-Maria A1 - Bierl, Rudolf A1 - Baeumner, Antje J. A1 - Hirsch, Thomas T1 - Graphene-enhanced plasmonic nanohole arrays for environmental sensing in aqueous samples JF - Beilstein Journal of Nanotechnology N2 - The label-free nature of surface plasmon resonance techniques (SPR) enables a fast, specific, and sensitive analysis of molecular interactions. However, detection of highly diluted concentrations and small molecules is still challenging. It is shown here that in contrast to continuous gold films, gold nanohole arrays can significantly improve the performance of SPR devices in angle-dependent measurement mode, as a signal amplification arises from localized surface plasmons at the nanostructures. This leads consequently to an increased sensing capability of molecules bound to the nanohole array surface. Furthermore, a reduced graphene oxide (rGO) sensor surface was layered over the nanohole array. Reduced graphene oxide is a 2D nanomaterial consisting of sp2-hybridized carbon atoms and is an attractive receptor surface for SPR as it omits any bulk phase and therefore allows fast response times. In fact, it was found that nanohole arrays demonstrated a higher shift in the resonance angle of 250–380% compared to a continuous gold film. At the same time the nanohole array structure as characterized by its diameter-to-periodicity ratio had minimal influence on the binding capacity of the sensor surface. As a simple and environmentally highly relevant model, binding of the plasticizer diethyl phthalate (DEP) via π-stacking was monitored on the rGO gold nanohole array realizing a limit of detection of as low as 20 nM. The concentration-dependent signal change was studied with the best performing rGO-modified nanohole arrays. Compared to continuous gold films a diameter-to-periodicity ratio (D/P) of 0.43 lead to a 12-fold signal enhancement. Finally, the effect of environmental waters on the sensor was evaluated using samples from sea, lake and river waters spiked with analytically relevant amounts of DEP during which significant changes in the SPR signal are observed. It is expected that this concept can be successfully transferred to enhance the sensitivity in SPR sensors. KW - diethyl phthalate KW - environmental sensing KW - nanohole array KW - nanosphere lithography KW - surface plasmon resonance Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:355-epub-398623 IS - 7 SP - 1564 EP - 1573 ER - TY - CHAP A1 - Hausler, Peter A1 - Genslein, Christa A1 - Roth, Carina A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Mikro-Opto-Elektro-Mechanisches Sensorsystem zur Oberflächenplasmonenresonanzspektroskopie T2 - MikroSystemTechnik Kongress 2017 : MEMS, Mikroelektronik, Systeme 23.-25. Oktober 2017 in München N2 - Gezeigt wird die Miniaturisierung eines Messsystems für Oberflächenplasmonenresonanzspektroskopie (SPR), einer markierungs-, sowie zerstörungsfreien als auch hoch sensitiven Technologie. Aufgrund der hohen Kosten klassischer SPR-Geräte wird sie bisher jedoch vornehmlich in der Bio- und Medizintechnik eingesetzt. Das Messprinzip ermöglicht die Erfassung von Brechungsindexänderungen nahe einer Oberfläche. Der Transfer dieser Technologie von Laborgeräten hin zu einem miniaturisierten Sensorsystem senkt die Kosten, macht das System robuster und ermöglicht so ein wesentlich breiteres Anwendungsspektrum. Ein sehr vielversprechendes Merkmal des hier vorgestellten Systems ist die Möglichkeit den SPR-Effekt winkelabhängig zur Lichtquelle ohne bewegliche Bauteile zu verfolgen. The miniaturization of Surface Plasmon Resonance (SPR) technology, which mainly finds its applications in pharmaceutical screening and biotechnology so far, is described. SPR spectroscopy is a label-free, non destructive and highly sensitive measurement principle which is capable of detecting changes in the refractive index in striking distance to a gold surface. A transfer of this technology to a miniaturized sensor will broaden the range of possible applications. A promising feature which is included in the miniaturized system is the angle-dependent recording of the SPR signals without moving parts. KW - Bewegungselement KW - Biotechnik KW - Brechungsindex KW - Goldoberfläche KW - Laborgerät KW - Lichtquelle KW - Medizintechnik KW - Messprinzip KW - Messsystem KW - Miniaturisierung KW - Oberflächenplasmon KW - Oberflächenplasmonenresonanzspektroskopie KW - pharmazeutisches Screening KW - Sensorsystem KW - Spektroskopie Y1 - 2017 SN - 978-3-8007-4491-6 IS - CD-ROM SP - 645 EP - 647 PB - VDE-Verlag CY - Berlin ER - TY - CHAP A1 - Hausler, Peter A1 - Holler, Sven A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - High integrated miniaturized sensor based on Surface Plasmon Resonance T2 - International Biosensor Conference, 11th Workshop on Biosensors & Bioanalytical Microtechniques in Environmental, Food & Clinical Analysis, BBMEC 11, 26.-30. September 2015, Regensburg, Germany Y1 - 2015 ER - TY - CHAP A1 - Hausler, Peter A1 - Holler, Sven A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Miniaturisierte Oberflächenplasmonenresonanz Sensorplattform T2 - MEMS, Mikroelektronik, Systeme, MikroSystemTechnik Kongress 2015, 26.- 28. Oktober 2015, Karlsruhe, proceedings Y1 - 2015 SN - 978-3-8007-4100-7 PB - VDE Verlag CY - Berlin ER - TY - CHAP A1 - Hausler, Peter A1 - Fischer, Johannes A1 - Wunderlich, Lukas A1 - Recum, Patrick A1 - Peller, Sebastian A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Miniaturisierte Sensoren basierend auf Oberflächenplasmonenresonanz, Chancen und Herausforderungen T2 - DGaO-Proceedings 2021 N2 - Derzeit gibt es zahlreiche Bereiche, wie Umwelt Monitoring und zivile Infrastruktur in denen geeignete Sensoren für die Überwachung der Systeme fehlen. SPR-basierte Sensoren haben das Potential diese Lücke zu schließen. Um für den Einsatz in der Umwelt tauglich zu werden, müssen die Sensoren noch robuster werden. Hier wird eine mögliche Lösung gezeigt. Y1 - 2021 UR - https://www.dgao-proceedings.de/download/122/122_a21.pdf PB - Dt. Gesellschaft für angewandte Optik CY - Erlangen-Nürnberg ER - TY - CHAP A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf T1 - Einbindung eines 2D-Photodetektors in einen hochintegrierten SPR-Imaging-Sensor T2 - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München N2 - Die Oberflächenplasmonenresonanzspektroskopie (SPR) ist eine hochempfindliche Messmethode, die es erlaubt, Gase und Flüssigkeiten zerstörungs- und markierungsfrei in Echtzeit zu analysieren. Bisher vornehmlich im Labormaßstab in der Bioanalytik und dem Wirkstoffscreening eingesetzt, soll diese Technologie nun miniaturisiert und für weitere Anwendungsgebiete zugänglich gemacht werden. Dazu wird ein kompakter Micro-Opto-Electro-Mechanical Systems Sensor (MOEMS) entwickelt, der mit Hilfe des SPR Imaging Änderungen der chemischen Zusammensetzung verschiedener Flüssigkeiten inline messen kann. N2 - Surface plasmon resonance spectroscopy (SPR) is a highly sensitive measurement method which allows the analysis of gases and liquids in real-time in a non-destructive and marking-free manner. Presently SPR is predominantly used for pharmaceutical screening and biotechnical analysis. Now this technology is to be miniaturized and made accessible for further application areas. For this purpose, a compact micro-opto-electro-mechanical system sensor (MOEMS) is developed, which can measure changes in the chemical composition of different fluids using SPR imaging. T2 - Integration of a 2D-photodetector in a SPR-Imaging-Sensor KW - Bildsensor KW - Bioanalytik KW - chemische Zusammensetzung KW - Fotodetektor KW - Labormaßstab KW - Messmethode KW - mikrooptoelektromechanisches System KW - Oberflächenplasmon KW - Oberflächenplasmonenresonanzspektroskopie KW - pharmazeutisches Screening KW - Spektroskopie KW - Wirkstoff Y1 - 2017 SN - 978-3-8007-4491-6 SP - 848 EP - 850 PB - VDE-Verlag CY - München ER -