TY - JOUR A1 - Beimler, Josef A1 - Leißl, Caroline A1 - Ebner, Lena A1 - Elsner, Michael A1 - Mühlbauer, Gerhard A1 - Kohlert, Dieter A1 - Schubert, Martin J. W. A1 - Weiß, Andreas P. A1 - Sterner, Michael A1 - Raith, Thomas A1 - Afranseder, Martin A1 - Krapf, Tobias A1 - Mottok, Jürgen A1 - Siemers, Christian A1 - Großmann, Benjamin A1 - Höcherl, Johannes A1 - Schlegl, Thomas A1 - Schneider, Ralph A1 - Milaev, Johannes A1 - Rampelt, Christina A1 - Roduner, Christian A1 - Glowa, Christoph A1 - Bachl, Christoph A1 - Schliekmann, Claus A1 - Gnan, Alfons A1 - Grill, Martin A1 - Ruhland, Karl A1 - Piehler, Thomas A1 - Friers, Daniel A1 - Wels, Harald A1 - Pflug, Kenny A1 - Kucera, Markus A1 - Waas, Thomas A1 - Schlachetzki, Felix A1 - Boy, Sandra A1 - Pemmerl, Josef A1 - Leis, Alexander A1 - Welsch, Andreas F.X. A1 - Graf, Franz A1 - Zenger, Gerhard A1 - Volbert, Klaus A1 - Waas, Thomas A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Störl, Uta A1 - Heyl, C. A1 - Boldenko, A. A1 - Monkman, Gareth J. A1 - Kujat, Richard A1 - Briem, Ulrich A1 - Hierl, Stefan A1 - Talbot, Sebastian A1 - Schmailzl, Anton A1 - Ławrowski, Robert Damian A1 - Prommesberger, Christian A1 - Langer, Christoph A1 - Dams, Florian A1 - Schreiner, Rupert A1 - Valentino, Piergiorgio A1 - Romano, Marco A1 - Ehrlich, Ingo A1 - Furgiuele, Franco A1 - Gebbeken, Norbert A1 - Eisenried, Michael A1 - Jungbauer, Bastian A1 - Hutterer, Albert A1 - Bauhuber, Michael A1 - Mikrievskij, Andreas A1 - Argauer, Monika A1 - Hummel, Helmut A1 - Lechner, Alfred A1 - Liebetruth, Thomas A1 - Schumm, Michael A1 - Joseph, Saskia A1 - Reschke, Michael A1 - Soska, Alexander A1 - Schroll-Decker, Irmgard A1 - Putzer, Michael A1 - Rasmussen, John A1 - Dendorfer, Sebastian A1 - Weber, Tim A1 - Al-Munajjed, Amir Andreas A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias A1 - Haug, Sonja A1 - Rudolph, Clarissa A1 - Zeitler, Annika A1 - Schaubeck, Simon A1 - Steffens, Oliver A1 - Rechenauer, Christian A1 - Schulz-Brize, Thekla A1 - Fleischmann, Florian A1 - Kusterle, Wolfgang A1 - Beer, Anne A1 - Wagner, Bernd A1 - Neidhart, Thomas ED - Baier, Wolfgang T1 - Forschungsbericht 2013 T3 - Forschungsberichte der OTH Regensburg - 2013 Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-7990 CY - Regensburg ER - TY - JOUR A1 - Mauerer, Wolfgang A1 - Rexhepaj, Tanja A1 - Monkman, Gareth J. A1 - Sindersberger, Dirk A1 - Diermeier, Andreas A1 - Neidhart, Thomas A1 - Wolfrum, Dominik A1 - Sterner, Michael A1 - Heberl, Michael A1 - Nusko, Robert A1 - Maier, Georg A1 - Nagl, Klaus A1 - Reuter, Monika A1 - Hofrichter, Andreas A1 - Lex, Thomas A1 - Lesch, Florian A1 - Kieninger, Bärbel A1 - Szalo, Alexander Eduard A1 - Zehner, Alexander A1 - Palm, Christoph A1 - Joblin, Mitchell A1 - Apel, Sven A1 - Ramsauer, Ralf A1 - Lohmann, Daniel A1 - Westner, Markus A1 - Strasser, Artur A1 - Munndi, Maximilian A1 - Ebner, Lena A1 - Elsner, Michael A1 - Weiß, Nils A1 - Segerer, Matthias A1 - Hackenberg, Rudolf A1 - Steger, Sebastian A1 - Schmailzl, Anton A1 - Dostalek, Michael A1 - Armbruster, Dominik A1 - Koch, Fabian A1 - Hierl, Stefan A1 - Thumann, Philipp A1 - Swidergal, Krzysztof A1 - Wagner, Marcus A1 - Briem, Ulrich A1 - Diermeier, Andreas A1 - Spreitzer, Stefan A1 - Beiderbeck, Sabrina A1 - Hook, Christian A1 - Zobel, Martin A1 - Weber, Tim A1 - Groß, Simon A1 - Penzkofer, Rainer A1 - Dendorfer, Sebastian A1 - Schillitz, Ingo A1 - Bauer, Thomas A1 - Rudolph, Clarissa A1 - Schmidt, Katja A1 - Liebetruth, Thomas A1 - Hamer, Markus A1 - Haug, Sonja A1 - Vernim, Matthias A1 - Weber, Karsten A1 - Saßmannshausen, Sean Patrick A1 - Books, Sebastian A1 - Neuleitner, Nikolaus A1 - Rechenauer, Christian A1 - Steffens, Oliver A1 - Kusterle, Wolfgang A1 - Gömmel, Roland A1 - Wellnitz, Felix A1 - Stierstorfer, Johannes A1 - Stadler, Dominik A1 - Hofmann, Matthias J. A1 - Motschmann, Hubert A1 - Shamonin (Chamonine), Mikhail A1 - Bleicher, Veronika A1 - Fischer, Sebastian A1 - Hackenberg, Rudolf A1 - Horn, Anton A1 - Kawasch, Raphael A1 - Petzenhauser, Michael A1 - Probst, Tobias A1 - Udalzow, Anton A1 - Dams, Florian A1 - Schreiner, Rupert A1 - Langer, Christoph A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian ED - Baier, Wolfgang T1 - Forschungsbericht 2016 T3 - Forschungsberichte der OTH Regensburg - 2016 Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13840 CY - Regensburg ER - TY - GEN A1 - Neidhart, Thomas A1 - Hallas, Martin A1 - Hinrichsen, Volker A1 - Tenzer, Michael A1 - Neumann, Claus T1 - Langzeitversuche an einer direkt erdverlegten DC GIL: Bodenmechanische und thermische Wechselwirkungen bei Bettung in zeitweise fließfähigem Verfüllbaustoff T2 - 22. Fachtagung Hochspannungsschaltanlagen: Anwendungen, Betrieb und Erfahrungen am 6. Okt. 2020, TU Darmstadt Y1 - 2020 UR - https://tuprints.ulb.tu-darmstadt.de/14131/1/11_GISAWF_FT_Neidhart_OTH%20Regensburg-hl.pdf ER - TY - GEN A1 - Neidhart, Thomas A1 - Spirkl, Florian T1 - Vergleichsberechnungen KMR-Bettung Sand versus ZFSV T2 - Fachtage Fernwärme - ZFSV in der Fernwärme: Forschung, Anwendung und Qualität, 2022, Kassel N2 - Im Beitrag wird auf die unterschiedlichen Bettungseigenschaften von Sand und zeitweise fließfähigen, selbstverdichtenden Verfüllbaustoffen (ZFSV) eingegangen. Zunächst wird kurz die versuchstechnische Ermittlung der Kontaktflächenarbeitslinie beschrieben, und anschließend dargestellt welchen Einfluss die angenommene/ermittelte Kontaktflächenarbeitslinie von Sand und ZFSV auf die ermittelten Verformungen und auftretenden Kräfte hat. KW - Baustoff KW - Berechnungsmodell KW - Bodenmechanik KW - Fernwärme KW - Kontaktwiderstand Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-73425 ER - TY - GEN A1 - Neidhart, Thomas A1 - Caicedo, José A1 - Bergforth, Axel T1 - Baugrundverbesserung mittels Kunstharzsäulen zur Nachgründung sich setzender Gebäude T2 - Vorträge der 38. Baugrundtagung, 25. bis 27. September 2024, Bremen N2 - Im Beitrag werden neben der Herstellung und Wirkungsweise auch die Ergebnisse von Versuchen im Maßstab 1:1 an neuartigen Kunstharzsäulen vorgestellt, die als ein minimalinvasives Injektionsverfahren speziell zur Nachgründung und Stabilisierung bestehender Bauwerke auf setzungsempfindlichen Untergrund mit geringer Tragfähigkeit entwickelt wurde. Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-77657 SN - 978-3-932653-57-5 SP - 89 EP - 94 PB - Aktiv Druck & Verlag GmbH CY - Ebelsbach ER - TY - CHAP A1 - Wolfrum, Dominik A1 - Neidhart, Thomas T1 - District heating pipes buried in Temporarily Flowable Backfill Materials T2 - Energy Procedia N2 - It is state of technology in district heating systems to use sand as backfill material for district heating pipes (DHP). In conventional pipeline construction, Temporarily Flowable Backfill Materials (TFB) have been already used for backfilling the pipe zone. TFB consists of the excavated material, cement, water and optionally bentonite. Environmental and economic advantages are that the excavated material can be reused and that TFB requires no compaction. In order to embed district heating pipes in TFB, soil mechanical parameters of the TFB are required. Above all the resistance to temperature-induced axial displacement should be well-known in order to estimate the displacements of the DHP, as well as the stress distribution along the DHP. Compared to sand as a non-cohesive backfill TFB have remarkable adhesive contact stresses which result in considerable resistance forces.In this article, the contact behavior between TFB and DHP is described as well as the effect on the DHP statics. Therefore, the results of various laboratory tests are summarized and presented to understand the interface-resistance-characteristics (IRC) of the DHP/ TFB interface. Then, the deduced IRC was implemented in a computer program for some comparative calculations with sand and TFB. Finally, the results of cyclic loading are presented and discussed. KW - ZFSV KW - pipe static KW - thermal expansion KW - Temporarily Flowable Backfill Material KW - buried pipeline KW - Fernheizung KW - Rohrleitung KW - Statik KW - Wärmeausdehnung KW - Füllstoff Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-276 UR - https://doi.org/10.1016/j.egypro.2018.08.181 VL - 149 SP - 170 EP - 178 ER - TY - GEN A1 - Leusink, Florian A1 - Neidhart, Thomas A1 - Ried, Michael A1 - Spirkl, Florian T1 - Zur Korrelation von einaxialer Druckfestigkeit und dynamischer California Bearing Ratio für ZFSV mit konventionellen und künstlicher Intelligenz basierten Methoden T2 - 6. D.A.CH-Tagung Flüssigboden, 05. – 06.09.2024, Dresden Y1 - 2024 ER - TY - RPRT A1 - Neidhart, Thomas A1 - Schuster, Markus T1 - Feldversuch zur Untersuchung des Bodenverbesserungseffekts durch Hybridinjektionskörper® BT - Abschlussbericht zum Feldversuch N2 - Die Bodenverbesserung mit HybridInjection® der Firma URETEK Deutschland GmbH ist ein Injektionsverfahren, das speziell unter bestehenden Bauwerken als Nachgründung oder Gründungsverstärkung zum Einsatz kommt, welche auf sehr schlecht tragfähigem Untergrund gegründet sind. Dabei werden dünne, mit einem Geotextil umwickelte Stangen (Injektionslanzen Ø = 12 mm) in den Untergrund eingebracht und anschließend das Textil mit Hilfe eines speziellen Harzes expandiert. Dadurch wird der umliegende Boden durch Verdrängung überwiegend radial verdrängt und verdichtet. Zudem wirken die moderat steifen, säulenartigen Expansionskörpern als Lastabtragungselemente und entlasten den Boden dazwischen, womit sie als Bodenverbesserungssäulen eingeordnet werden können. Ziel der gemeinsamen Forschungsarbeit ist es diesen Verbesserungseffekt messtechnisch zu erfassen und zu beziffern, um dadurch das Produkt wirtschaftlicher und auf die jeweilige Lastsituation anbieten zu können. Dazu wurde auf einem Versuchsfeld eine 6,0 m² große Stahlbetonplatte, welche das Fundament eines Gebäudes darstellen soll, mit Hilfe eines 1,5 MN-Hydraulikzylinders in verschiedenen Stufen belastet und die daraus resultierenden Setzungen des Bodens gemessen. Dies geschah zunächst ohne und anschließend mit vier, rechteckig unter der Betonplatte angeordneten Expansionskörpern der Firma URETEK. Der Vorher-Nachher-Vergleich der verschiedenen Auswertungen zeigte, dass der Boden nach dem Einbau der HybridInjection® insgesamt deutlich steifer reagiert. Verglichen wurden dafür das Maß der Setzungen, die Kriechzahl in Anlehnung an die EA-Pfähle, der Verformungsmodul in Anlehnung an den Lastplattendruckversuch, Setzungen und E-Moduln in der Tiefe ermittelt aus Extensometermessungen und zuletzt die Schlagzahlen leichter Rammsondierungen. Die Verbesserungsfaktoren fallen recht unterschiedlich aus und belaufen sich auf Änderungen um bis zu + 68% im Vergleich zum Ausgangszustand ohne Bodenverbesserung. KW - Baugrund KW - Bodenverbesserung Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-21723 CY - Regensburg ER - TY - RPRT A1 - Neidhart, Thomas A1 - Lerch, Maximilian A1 - Wiesinger, Doris A1 - Zrenner, Louis T1 - Kompakte Übertragungsleitungen für hohe Gleichspannungen: Langzeituntersuchungen an einer erdverlegten Versuchsanlage BT - Abschlussbericht zu AP 1.5 Mechanik und AP 1.7 Thermik; Forschungsprojekt-Akronym: DC CTL DBI; Förderkennzeichen: 03ET7546 N2 - Durch den Ausstieg aus der Verstromung fossiler Energieträger und der daraus resultierenden dezentralen Stromerzeugung ist ein Aus- bzw. Umbau des deutschen Übertragungsnetzes erforderlich. Weil aus der dezentralen Energieerzeugung große Trassenlängen resultieren, welche bei Wechselstrom zu Blindleistungsproblematiken führen, wird dort vermehrt auf Hochspannungs-Gleichstrom-Übertragung zurückgegriffen. Im Rahmen des Forschungsprojekts DC CTL DBI (direct current compact transmission line – directly buried investigastions) wurde ein gasisolierte HGÜ-Leiter (GIL) erdverlegt und bei ständigem Monitoring über umfangreiche Sensorik einem Langzeitversuch unterzogen. Anstelle einer klassischen Sandbettung kam ein zeitweise fließfähiger, selbstverdichtender Verfüllbaustoff (ZFSV) zum Einsatz. Somit können Schäden an der Übertragungsleitung infolge Verdichtungsaufwand vermieden und gleichzeitig bessere Bodeneigenschaften hinsichtlich der Wärme- und Wassertransportprozesse erreicht werden. KW - ZFSV KW - Erdverlegte Übertragungsleitungen KW - Erdkabel KW - Zeitweise fließfähiger selbstverdichtender Verfüllbaustoff KW - Wärmetransport Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-21730 ER - TY - CHAP A1 - Neidhart, Thomas A1 - Gömmel, Roland ED - Ruttloff, Liane T1 - Spreizverformungen von Erddämmen auf Säulen und Pfählen BT - Betrachtungen zur Spannungs- und Verformungskompatibilität T2 - 7. Fachtagung Geotechnik an der HTW Dresden, 23.11.2023 N2 - Nach Einführung in die Thematik werden unter Berücksichtigung der EBGEO und des aktuellen Entwurfs des neuen Eurocodes 7, Teil 3 numerische Berechnungen zur Beanspruchung unbewehrter pfahlartiger Tragglieder/ Stabilisierungssäulen aufgrund von Spreizverformungen von Erddämmen durchgeführt. Dabei werden u.a. die Materi-aleigenschaften der Tragglieder und die Dehnsteifigkeiten eingelegter Geogitter variiert sowie deren Einflüsse auf die Verdrehung und Verbiegung der Tragglieder aufgezeigt. Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-67639 UR - https://www.zaft.htw-dresden.de/FtG/ftg2023/2023_t_tb_Neidhart.pdf ER - TY - GEN A1 - Spirkl, Florian A1 - Ried, Michael A1 - Neidhart, Thomas T1 - CO2-Einsparpotenzial alternativer Bauverfahren am Beispiel von Spezialtiefbau und Rohrgrabenverfüllung T2 - Neue Herausforderungen in der Geotechnik - Nachhaltigkeit, Energiewende & Klimawandel; Beiträge zum 38. Christian Veder Kolloquium : 04. und 05. April 2024, Graz Y1 - 2024 SP - 23 EP - 36 PB - Technische Universität Graz CY - Graz ER - TY - JOUR A1 - Spirkl, Florian A1 - Neidhart, Thomas T1 - Lasttransferschichten über pfahlartigen Traggliedern – Überblick und Vergleich analytischer und numerischer Lösungen JF - geotechnik N2 - Der Einbau mineralischer, granularer Lasttransferschichten (LTS) zwischen einem Bau-werk und einer Tiefgründung z. B. aus pfahlartigen Traggliedern (PTG) beeinflusst erheb-lich die Lastaufteilung auf die PTG und den zumeist weichen Boden dazwischen. Eine genaue Kenntnis über die Lastaufteilung ist für die Bemessung der LTS und PTG, aber auch des darauf gegründeten Bauwerks erforderlich. Für die Quantifizierung der Lastauf-teilung wurden eine Vielzahl an Berechnungsansätzen entwickelt, welche zumeist auf Modell- oder Großversuchen basieren, aus deren Ergebnissen analytische Ansätze entwi-ckelt wurden. Zunächst werden ausgewählte Berechnungsansätze zur Lastaufteilung vor-gestellt, dann mit Hilfe von Finite-Element-Berechnungen der Einfluss verschiedener Parameter auf die Lastaufteilung veranschaulicht und diskutiert. Für geringe Dicken der LTS ergibt sich dabei eine hohe Übereinstimmung der FE-Berechnungen mit einem Durchstanzmechanismus. Ab einer bestimmten Dicke der LTS, abhängig von ver-schiedensten Randbedingungen, bildet sich in den FE-Berechnungen ein Gewölbe aus. Das Einstanzen der PTG in die LTS kann dann durch einen Grundbruchmechanismus beschrieben und als obere Begrenzung der Lastumlagerung auf die PTG angesehen wer-den. Anhand zahlreicher Vergleichsberechnungen konnte gezeigt werden, dass die beiden Mechanismen Durchstanzen und Grundbruch in sehr vielen Fällen ausreichen, um die Lastaufteilung auch ohne FE-Berechnungen abzuschätzen. KW - pfahlartige Tragglieder KW - Stabilisierungssäulen KW - Lasttransferschicht KW - Lastverteilungsschicht KW - Durchstanzen KW - Grundbruch KW - Bodengewölbe KW - FEM KW - PLAXIS KW - Eurocode 7 Y1 - 2024 U6 - https://doi.org/10.1002/gete.202400003 VL - 47 IS - 3 PB - Ernst & Sohn ER - TY - CHAP A1 - Wagner, Bernd A1 - Neidhart, Thomas T1 - Die axiale Bettung von KMR in ZFSV und Sand T2 - "Dumme" Rohre - "Intelligente" Netze: Modelle, Simulation und Steuerung von Infrastrukturen, 30. Oldenburger Rohrleitungsforum N2 - Die Verlegung von Kunststoffverbundmantelrohren (KMR) im Fernwärmeleitungsbau ausschließlich in zeitweise fließfähigen, selbstverdichtenden Verfüllbaustoffen (ZFSV) in der Leitungszone anstelle in Sand, ist weitgehend neu. Interesse an dieser Methode besteht aus technischer Sicht infolge höherer nachgewiesener Haltekräfte in Technikums- und Laborversuchen, die die Leitungsbewegungen reduzieren können. Es existiert jedoch noch kein praxistaugliches Berechnungsmodell bzw die Grundlagen hierfür. U.a. deswegen wird derzeit an der Ostbayerischen Technischen Hochschule Regensburg (OTH.R) das Forschungsvorhaben "EnEff: Wärme - Innovative Fernwärmeverteilung - Einsatz fließfähiger Verfüllbaustoffe zur KMR-Verlegung, Arbeitspaket Bodenmechanik" durchgeführt. Es wird im Referat der Unterschied der axialen Bettung von KMR in ZFSV und Sand anhand einer analytischen Lösung vorgestellt. Diese erlaubt die Berechnung von Verschiebungen und Normalkräften für das KMR für die Bettung in ZFSV erfolgt dies unter Verwendung der mittels eines neuartigen Versuchs(behalters) Re-SIST nun bestimmbaren bisher unbekannten Kontaktwiderstandsarbeitslinie zwischen ZFSV und PE. Zur Verdeutlichung der Unterschiede bei Sand- und ZFSV-Bettung werden Ergebnisse einer vergleichenden Berechnung an einer sonst identischen KMR-Leitung vorgestellt. Diese zeigen, dass in ZFSV die Verschiebungen geringer ausfallen und weniger Leitungslange in Bewegung ist, was sich mit Beobachtungen an einer Fernwärmeleitung in Ulm deckt. Die Ausführungen gelten für das erstmalige Warmgehen. KW - analytische Lösung KW - Baustoff KW - Berechnungsmodell KW - Bodenmechanik KW - Fernwärme KW - Forschungsvorhaben KW - Kontaktwiderstand KW - Laborversuch KW - Normalkraft KW - technische Hochschule KW - Verlegung Y1 - 2016 SN - 978-3-8027-2799-3 SP - 736 EP - 751 PB - Vulkan-Verlag CY - Essen ER - TY - CHAP A1 - Pankrath, Holger A1 - Gömmel, Roland A1 - Alber, D. A1 - Neidhart, Thomas T1 - Stabilising Columns – design recommendations T2 - XVI Panamerican Conference on Soil Mechanics and Geotechnical Engineering, Cancun, Mexico, 17. - 20.11.2019, TC205-meeting Y1 - 2019 PB - IOS Press ER - TY - JOUR A1 - Wagner, Bernd A1 - Neidhart, Thomas A1 - Weidlich, Ingo A1 - Schleyer, A. T1 - Innovative Fernwärmeverteilung: Einsatz fließfähiger Verfüllbaustoffe zur KMR-Verlegung JF - Euroheat & power : Wärme, Kälte, Kraft-Wärme-Kopplung T2 - Innovative district heat distribution: Use of flowable backfill materials for laying plastic sheath composite pipes Y1 - 2013 SN - 0949-166X VL - 42 IS - 9 SP - 54 EP - 56 PB - VDE-Verlag ER - TY - GEN A1 - Neidhart, Thomas A1 - Weidlich, Ingo T1 - Grundlagen zur statischen Berechnung mit ZFSV T2 - Projektabschlussveranstaltung „Verbundvorhaben: EnEff:Wärme: FW-ZFSV 4.0“ KW - Baustoff KW - Berechnungsmodell KW - Bettungsmaterial KW - Fernwärme KW - ZFSV Y1 - 2024 UR - https://www.agfw.de/zfsv ER - TY - CHAP A1 - Neidhart, Thomas A1 - Gömmel, Roland T1 - Spreizverformungen von Erddämmen auf Säulen und Pfählen - Betrachtungen zur Spannungs- und Verformungskompatibilität T2 - 7. Fachtagung Geotechnik an der HTW Dresden, 23. November 2023, Dresden N2 - Nach Einführung in die Thematik werden unter Berücksichtigungen der EBGEO und des aktuellen Entwurfs des neuen Eurocodes 7, Teil 3 numerische Berechnungen zur Beanspruchung unbewehrter pfahlartiger Tragglieder / Stabilisierungssäulen aufgrund von Spreizverformungen von Erddämmen durchgeführt. Dabei werden u.a. die Materialeigenschaften der Tragglieder und die Dehnsteifigkeiten eingelegter Geogitter variiert, sowie deren Einflüsse auf die Verdrehung und Verbiegung der Tragglieder aufgezeigt. Y1 - 2023 UR - https://www.zaft.htw-dresden.de/FtG/ftg2023/2023_t_tb_Neidhart.pdf CY - Dresden ER - TY - CHAP A1 - Gömmel, Roland A1 - Neidhart, Thomas T1 - Zum Ansatz von Stabilisierungssäulen beim Nachweis der Gesamtstandsicherheit T2 - 10. Kolloquium Bauen in Boden und Fels, Technische Akademie Esslingen, 19. + 20. Januar 2016, Esslingen Y1 - 2016 SN - 978-3-943563-21-4 ER - TY - CHAP A1 - Wagner, Bernd A1 - Neidhart, Thomas A1 - Gömmel, Roland T1 - Bodenmechanische Eigenschaften von ZFSV und zementbasierte Prognosemodelle zur Druckfestigkeitsentwicklung T2 - 10. Kolloquium Bauen in Boden und Fels, Technische Akademie Esslingen, 19. + 20. Januar 2016, Esslingen N2 - Der wissenschaftliche Untersuchungsstand von Zeitweise fließfähigen, selbstverdichtenden Verfüllbaustoffen (ZSFV) unter Zugabe von Zement und/ oder Bentonit sowie Wasser zu Grundmaterial ist gering. Die OTH Regensburg (OTH.R) untersucht im Forschungsvorhaben EnEff systematisch verschiedene ZFSV für den Einsatz im Infrastrukturbau, speziell Fernwärmeleitungen. Neben der dort hauptsächlich interessierenden Kontaktmechanik zu axialen Temperaturdehnungsbehinderung werden bodenmechanische Eigenschaften und deren Zeitabhängigkeit untersucht. Im Beitrag werden nach einer einführenden Charakterisierung von ZFSV und kurzen Darstellung der Bedeutung der Zugabe von Zement und Bentonit Ergebnisse von bodenmechanischen Untersuchungen in Abhängigkeit des Materialalters und teilweise in Referenz zum Grundmaterial (hier: Boden) vorgestellt. Im Weiteren werden zwei auf ZFSV adaptierte, zementbasierte Prognosemodelle zur Vorhersage der zeitlichen Entwicklung der Druckfestigkeit vorgestellt. Y1 - 2016 SN - 978-3-943563-21-4 SP - 125 EP - 142 ER - TY - JOUR A1 - Gömmel, Roland A1 - Neidhart, Thomas T1 - Nachweis gegen Grundbruch bei Fundamenten auf Stabilisierungssäulen JF - Konstruktiver Ingenieurbau N2 - Stabilisierungssäulen sind hydraulisch abgebundene und unbewehrte, schlanke, pfahlartige Tragglieder, welche in der Praxis zunehmend als ökonomische Alternative zu Tieferführungen, Pfahlgründungen oder Bodenaustauschmaßnahmen eingesetzt werden. Bei der Anwendung von Stabilisierungssäulen sind grundsätzlich zwei wesentliche Einsatzzwecke zu unterscheiden: Ableitung oberflächlicher Lasten in tieferliegende tragfähigere Schichten (Setzungsreduktion) vs. Erhöhung der Gesamtstandsicherheit (Böschungsbruch, Grundbruch). In beiden Fällen ist jedoch eine eingehende Berücksichtigung des Lastabtragungsverhaltens und der Interaktion zwischen Boden und Stabilisierungssäulen erforderlich. Aufgrund der im Vergleich zu konventionellen Pfählen geringeren Durchmesser sowie der fehlenden Bewehrung versagen die Tragglieder bereits bei geringen Querbeanspruchungen. Die beim Verlust der Gesamtstandsicherheit auftretenden Versagensmechanismen der Stabilisierungssäulen werden nicht durch die in den bestehenden Normen getroffenen Annahmen abgedeckt, wodurch in der Praxis verbreitete Ansätze, wie z. B. die Berücksichtigung der Stabilisierungssäulen über „verschmierte Bodenparameter“ den Beitrag der Tragglieder zumeist deutlich überschätzen. Im vorliegenden Beitrag wird die Wirkungsweise von Stabilisierungssäulen bei axialer und lateraler Beanspruchung erläutert und anschließend ein praxisnaher Ansatz aufgezeigt, wie Stabilisierungssäulen beim Nachweis gegen Grundbruch eines Streifenfundaments berücksichtigt werden können. Y1 - 2021 SN - 2509-2847 IS - 3 SP - 5 EP - 11 PB - Reguvis Fachmedien ER - TY - CHAP A1 - Neidhart, Thomas A1 - Gömmel, Roland T1 - Wie versagen unbewehrte pfahlartige Tragglieder? T2 - 6. Fachtagung Geotechnik an der HTW Dresden, 22. November 2018, Dresden N2 - Pfahlartige Tragglieder haben häufig einen geringeren Durchmesser als Pfähle, binden im Fußbereich nur unwesentlich in tragfähige Schichten ein und sind zudem unbewehrt. Für die Nachweise der Tragfähigkeit und Gesamtstandsicherheit sind die Kenntnisse der aktivierbaren Widerstände und der Versagensarten von grundlegender Bedeutung, was die eingehende Berücksichtigung des Lastabtragungsverhaltens sowie der Interaktion zwischen Boden und unbewehrten, pfahlartigen Tragglieder unumgänglich macht. Im vorliegenden Beitrag werden zunächst mögliche Versagensmechanismen vorgestellt und erläutert. Danach wird aufgezeigt, unter welchen Bedingungen und Beanspruchungen der jeweilige Versagensmechanismus auftritt und welche Widerstände dabei aktiviert werden können. Anschließend wird deren Übertragbarkeit und Anwendung der auf unbewehrte, pfahlartige Tragglieder dargestellt und u.a. mittels FE-Berechnungen überprüft. Schwerpunktmäßig wird dabei die Interaktion zwischen unbewehrten, pfahlartigen Traggliedern und dem umgebenden Boden beim Nachweis der Gesamtstandsicherheit behandelt. Y1 - 2018 ER - TY - CHAP A1 - Gömmel, Roland A1 - Neidhart, Thomas T1 - Unbewehrte pfahlartige Tragglieder beim Nachweis der Gesamstandsicherheit T2 - 14. Hans-Lorenz-Symposium am 10. Oktober 2018, Technische Universität Berlin, Berlin Y1 - 2018 SP - 1 EP - 10 ER - TY - GEN A1 - Gömmel, Roland A1 - Neidhart, Thomas T1 - Berücksichtigung von StS beim Nachweis der Gesamtstandsicherheit BT - Benutzerhandbuch zur Implementierung in die Softwarepakete GGU und DC Y1 - 2020 CY - Regensburg ER - TY - CHAP A1 - Gömmel, Roland A1 - Neidhart, Thomas T1 - Ansatz von Stabilisierungssäulen beim Nachweis der Gesamtstandsicherheit und beim Nachweis gegen Grundbruch T2 - 11. Österreichische Geotechniktagung Vienna - Terzaghi Lecture, Österreichischer Ingenieur- und Architekten-Verein, 02. + 03. Februar 2017, Wien N2 - Stabilisierungssäulen (StS) sind überwiegend hydraulisch abgebundene, unbewehrte, schlanke, pfahlartige Tragglieder, deren Versagensmechanismen es nicht erlauben, die Widerstände gegen Versagen näherungsweise über „verschmierte Bodenparameter“ – wie z. B. bei Rüttelstopfsäulen üblich – zu berücksichtigen. Der Arbeitskreis 2.8 – Stabilisierungssäulen der Deutschen Gesellschaft für Geotechnik erarbeitet derzeit Empfehlungen zur Anwendung und rechnerischen Berücksichtigung von StS. Im vorliegenden Beitrag wird ein Ansatz zur Berücksichtigung aufstehender StS in einfach geschichteten Böden beim Nachweis der Gesamtstandsicherheit sowie gegen Grundbruch vorgestellt. Der entwickelte Ansatz beruht im Grundsatz auf Broms / Kivelö und ist mit dem EC 7 konform. Der Berechnungsablauf sowie die dazu nötigen Annahmen werden vorgestellt und erläutert. In einem abschließenden Berechnungsbeispiel wird der Nachweis gegen Grundbruch eines Streifenfundamentes unter Berücksichtigung von StS geführt. Y1 - 2017 SN - 978-3-902450-05-0 ER - TY - RPRT A1 - Gömmel, Roland A1 - Neidhart, Thomas T1 - Untersuchung des Expansionsverhaltens von Traggliedern aus PUR-Expansionsharz T2 - Forschungsbericht 2016 / Ostbayerische Technische Hochschule Regensburg N2 - Klimatische Veränderungen haben in den letzten Jahren zu einem starken Anstieg an Gebäudeschäden geführt, die häufig auf Setzung des Bodens infolge von Austrocknung zurückzuführen sind. Durch die Expansion säulenartiger PUR-Tragelemente unter den Fundamenten können derartige Setzungsschäden behoben werden. Im Rahmen eines Forschungsauftrags im Labor für Geotechnik der OTH Regensburg wurde durch Herstellung von PUR-Gründungselementen unter Laborbedingungen das Expansionsverhalten eines Zweikomponenten-PUR-Schaumes in Abhängigkeit verschiedener isotroper Druckverhältnisse untersucht. Zur Optimierung dieses Bauverfahrens wurden die Materialeigenschaften der expandierten Proben durch labortechnische Untersuchungen ermittelt und einfache Korrelationen zwischen Expansionswiderständen und Materialeigenschaften erstellt. Y1 - 2016 UR - https://doi.org/10.35096/othr/pub-1384 SP - 66 EP - 67 ER - TY - CHAP A1 - Neidhart, Thomas A1 - Gömmel, Roland T1 - Nachweisführung von Dammbauwerken auf Stabilisierungssäulen T2 - 13. Erdbaufachtagung "Sicherungen im Erd-, Fels- und Grundbau, Bauakademie Sachsen, 02. + 03. März 2017, Leipzig N2 - Stabilisierungssäulen (StS) sind überwiegend hydraulisch abgebundene, unbewehrte, schlanke, pfahlartige Traggliede, deren Versagensmechanismen es nicht erlauben, die Widerstände gegen Versagen näherungsweise über "verschmierte Bodenparameter" - wie z. B. bei Rüttelstopfsäulen üblich - zu berücksichtigen. Der Arbeitskreis 2.8 - Stabilisierungssäulen der Deutschen Gesellschaft für Geotechnik erarbeitet derzeit Empfehlungen zur Anwendung und rechnerischen Berücksichtigung von StS. Im vorliegenden Beitrag wird ein Ansatz zur Berücksichtigung aufstehender StS in einfach geschichteten Böden beim Nachweis der Gesamtstandsicherheit sowie gegen Grundbruch vorgestellt. Der entwickelte Ansatz beruht im Wesentlichen auf Broms / Kivelö und ist mit dem EC 7 konform. Der Berechnungsablauf sowie die dazu nötigen Annahmen werden vorgestellt und erläutert. In einem abschließenden Berechnungsbeispiel wird der Nachweis gegen Grundbruch eines Streifenfundamentes unter Berücksichtigung von StS geführt. Y1 - 2017 ER - TY - CHAP A1 - Wagner, Bernd A1 - Neidhart, Thomas T1 - A new backfill material enhancing axial bedding of district heating pipes T2 - Energy Geotechnics - Proceedings of the 1st International Conference on Energy Geotechnics, ICEGT 2016, Kiel, Germany, 29-31 August 2016 N2 - District heating cost reduction efforts are amongst others focusing on the use of a new backfillmaterial. The OTH.R is investigating this material in regard to the engineering of buried district heating pipes.The main focus of this soil-structure interaction problem is axial bedding to reduce thermal induced elongations.The backfill material is characterized and an axial non-linear spring-based calculation method is described.Centerpiece of the method is the contact-working-resistance-line (CWRL).A new Rod-Shear-Test based testingdevice Re-SIST to investigate the CWRL for the new backfill material is presented. The investigated CWRL isdescribed and compared to the CWRL for sand, which is the conventional backfill material. Solutions using thespring-based calculation method are presented and a comparative example of calculation shows the differencein axial bedding when the new backfill material is used. Y1 - 2016 SN - 978-1-138-03299-6 U6 - https://doi.org/10.1201/b21938 SP - 105 EP - 112 PB - CRC Press CY - London ER - TY - CHAP A1 - Neidhart, Thomas ED - Wegener, Thomas T1 - Bodenphysikalische und bodenmechanische Anforderungen an ZFSV (Flüssigboden) als Bettungsmaterialien erdverlegter Hochspannungsleitungen T2 - Rohrleitungen in digitalen Arbeitswelten : Tagungsband zum 31. Oldenburger Rohrleitungsforum 2017 Y1 - 2017 SN - 978-3-8027-2865-5 SP - 337 PB - Vulkan Verlag CY - Essen ER - TY - GEN A1 - Wolfrum, Dominik A1 - Neidhart, Thomas T1 - Kontaktverhalten zwischen warmgehenden Rohren und ZFSV T2 - 4. Flüssigbodentagung D-A-CH : zum aktuellen Stand der Wissenschaft, Forschung und Entwicklung ; Koblenz 22.02.2017 Y1 - 2017 UR - https://idw-online.de/de/attachmentdata56257.pdf ER - TY - GEN A1 - Neidhart, Thomas T1 - Einführung in die Thematik "Zulassungen" und das Fräs-Misch-Injektionsverfahren (FMI) T2 - 11.Tiefbaufachtagung in Dresden, 08. - 09-02.2017 Y1 - 2018 ER - TY - CHAP A1 - Spirkl, Florian A1 - Neidhart, Thomas ED - Moormann, Christian ED - Vogt-Breyer, Carola T1 - Lastaufteilung in Lastverteilungsschichten über Stabilisierungssäulen T2 - 13. Kolloquium Bauen in Boden und Fels, Fachtagung über aktuelle Herausforderungen der Geotechnik: Tagungshandbuch 2022, 1. und 2. Februar 2022, Ostfildern N2 - Stabilisierungssäulen mit darüberliegender Lastverteilungsschicht stellen eine wirtschaftliche, technisch sichere Alternative zur klassischen Tiefgründungen dar. Dabei ist eine möglichst genaue Kenntnis über die Aufteilung der Lasten zwischen Säulen und Weichschicht erforderlich. Für die Quantifizierung der Lastverteilung wurden schon eine Vielzahl an Berechnungsansätze entwickelt. Zunächst wird eine Auswahl an Ansätzen vorgestellt, die eine direkte Berechnung der Lastumlagerung ermöglichen. Diese Berechnungsansätze werden anhand der zu Grunde liegenden Modelle und Randbedingungen sowie der prognostizierten Lastumlagerung verglichen. Anschließend werden die direkten Ansätze mit Berechnungen der Last-Transfer-Methode und der Finite-Element-Methode verglichen. Abschließend wird detailliert auf die FE-Berechnungen, insbesondere die Lastumlagerung für Lastverteilungsschichten geringer Mächtigkeiten, eingegangen. Dabei konnte eine sehr gute Übereinstimmung des vorgestellten Ansatzes mit den Ergebnissen der Finite-Element-Methode erzielt werden. Y1 - 2022 SP - 287 EP - 297 PB - expert CY - Tübingen ER - TY - JOUR A1 - Grimm, Sebastian A1 - Huther, Heiko A1 - Neidhart, Thomas A1 - Weidlich, Ingo T1 - Einsatz fließfähiger Verfüllstoffe zur KMR-Verlegung in Gräben und Haubenkanälen JF - Bbr : Leitungsbau, Brunnenbau, Geothermie N2 - Zeitweise fließfähige, selbstverdichtende Verfüllbaustoffe (ZFSV) sind zwar seit Jahrzehnten bei zahlreichen Gewerken im Einsatz - in der Fernwärmebranche hingegen sind sie bis heute erst in Ansätzen etabliert. Auf Grundlage einer Befragung von AGFW-Mitgliedem wurden Vorbehalte und Hindernisse identifiziert, die einer breiten Anwendung von ZFSV im Wege stehen. Im Rahmen eines anschließenden, vom Bundesministerium für Wirtschaft und Energie (BMWi) geförderten Forschungsvorhabens untersuchten der AGFW Energieeffizienzverband für Wärme, Kälte und KWK, die Hochschule OTH.R und die GEF Ingenieur AG systematisch die fernwärmerelevanten Eigenschaften von ZFSV. Neben der Prüfung grundlegender Materialeigenschaften wurden hierbei auch Laborversuche sowie ein Feldversuch durchgeführt. Nach den bisherigen Erkenntnissen lassen sich die Ergebnisse aus den Laboruntersuchungen auf das Feld übertragen. Demnach erfüllt ZFSV die notwendigen Anforderungen, um bei richtiger Anwendung im Fernwärmeleitungsbau eingesetztzu werden. Für den Umgang mit ZFSV bieten die von der Forschungsgesellschaft für Straßen- und Verkehrswesen erstellten "Hinweise für die Herstellung und Verwendung von zeitweise fließfähigen, selbstverdichtenden Verfüllbaustoffen im Erdbau (H ZFSV)" eine gute Grundlage. Die darin enthaltenen Empfehlungen und Besonderheiten im Umgang mit ZFSV, die bereits Ansätze zu deren Einsatz im Fernwärmebereich liefern, wurden im Projekt berücksichtigt und im Abschlussbericht um die gewonnenen Erkenntnisse erweitert. Der Abschlussbericht des Forschungsvorhabens, der in Kürze veröffentlicht wird, wird vor allem die Fernwärmespezifischen Details zu notwendigen Anforderungen, entsprechenden Prüfverfahren sowie Besonderheiten im Baustellenablauf darstellen. Weiterhin wird ein Vorschlag für einen LV-Text (LV = Leistungsverzeichnis) erstellt, der ebenso im Abschlussbericht enthalten sein wird wie weitere Details zu bautechnischen, sicherheitstechnischen, ökologischen und ökonomischen Auswirkungen, die der Einsatz von ZFSV mit sich bringen kann. KW - Baustoff KW - Energieeffizienz KW - Erdbau KW - Feldversuch KW - Fernwärme KW - Forschungsvorhaben KW - Graben KW - Kälte KW - Laboruntersuchung KW - Laborversuch KW - Materialeigenschaft KW - Prüfverfahren KW - Verkehrswesen KW - Wärme Y1 - 2017 SN - 1611-1478 VL - 68 IS - 5 SP - 18 EP - 25 ER - TY - CHAP A1 - Neidhart, Thomas T1 - Bodenmechanische und erdbautechnische Aspekte der Erdverkabelung T2 - Geotechnik - Zusammenwirken von Forschung und Praxis, Beiträge zum Geotechnik-Tag in München, 06.04.2018, Tagungsband N2 - Da oberirdische Stromleitungen bei der Bevölkerung zunehmend auf Widerstände stoßen, werden große Abschnitte der geplanten Nord-Süd-Stromtrassen in Gräben verlegt und sollen mit bis zu 525 kV Gleichstrom (DC) betrieben werden. Bei den Netzbetreibern wird diese Art der Verlegung zumeist als "Erdverkabelung" bezeichnet, wobei nicht nur Kabel, sondern auch Stromrohre verlegt werden. Die Ausbildung der Trassen mit erdverlegten Kabeln oder Rohren kann auf der Homepage der Bundesnetzagentur abgerufen werden. Weiterhin gibt es einige Bauvorhaben, wie z.B. EnLAG5 Diele - Niederrhein in NRW, das bereits abschnittsweise als Erdkabelpilotprojekt mit 380 kV Wechselstrom (AC) realisiert wurde. Während bauzeitlich zur Zwischenlagerung des Bodenaushubs Baustreifen von bis zu 42 m benötigt werden, verbleiben nach dem Bau lediglich Schutzstreifen von maximal 11 m Breite. Die Mindestüberdeckung der Kabelschutzrohre beträgt 1,30 m, wobei für den Bau von Regel-Kabelgraben-Profilen nach DIN 4124 mit etwa 1,65 m tiefer Grabensohle ausgegangen wird. Bei erdverlegten Kabeln mit Kupfer- oder Aluminiumkern stellen für Planung und Bau wesentlichen Kriterien die Größe und das Gewicht der gerade noch transportierbaren Kabeltrommeln dar, auf denen zurzeit etwa Kabellängen von 800 - 1000 m aufgewickelt sind. Dies bedingt Kabelmuffen mit entsprechenden Trassenabständen, an denen die Kabelstücke miteinander zu verbinden sind. Erdverlegte Stromkabel werden im Allg. in Schutzrohren aus Kunststoff (HDPE) verlegt und können bei Beschädigung zwischen den Muffenstationen ausgewechselt werden. Bei erdverlegten Stromrohre werden - ähnlich wie beim Pipelinebau - zunächst einzelne Rohrstücke aus Aluminium miteinander verschweißt und dann in einen Graben verlegt, wodurch theoretisch "endlose" Stromrohre realisierbar wären. Siemens setzt hier auf gasisolierte Innenleiter aus Aluminium, die von einem gas- und druckdichten Schutz-/ Außenrohr umgeben ist. Der Innenleiter wird mittels Stützisolatoren zentrisch im Außenrohr gehalten. Bei Erdverlegung wird das Außenrohr mit einer Schutzhülle aus HDPE umgeben. Auch hier sind schon Pilotstrecken realisiert und unter Betrieb. KW - Aluminium KW - Bevölkerung KW - Bundesnetzagentur KW - DIN-Norm KW - Erdkabel KW - Gleichstrom KW - Graben KW - Kabelmuffe KW - Kabelschutz KW - Kabeltrommel KW - Netzbetreiber KW - Pilotprojekt KW - Schutzhülle KW - Schutzrohr KW - Stromkabel KW - Trasse KW - Verlegung KW - Wechselstrom Y1 - 2018 UR - http://www.gb.bv.tum.de/main-zg.htm SN - 978-3-943683-47-9 VL - 64 SP - 17 EP - 29 PB - TU München, Zentrum Geotechnik CY - München ER - TY - JOUR A1 - Lerch, Maximilian A1 - Neidhart, Thomas A1 - Bubenicek, Michal A1 - Pandrea, Paul T1 - Ableitung der Tragfähigkeit aus Probebelastungen an Betonstopfsäulen BT - Bericht JF - geotechnik N2 - Neben den konventionellen Pfahlgründungen werden bei ungünstigen Baugrundverhältnissen oft pfahlartige Tragglieder verwendet, um den Anforderungen an Gebrauchstauglichkeit und Standsicherheit bei der Gründung von Bauwerken gerecht zu werden. Um Erkenntnisse über das Tragverhalten der Säulen zu erlangen, wurden Probebelastungen durchgeführt. Hierbei kamen statische und dynamische Probebelastungen zum Einsatz. Die Tragglieder wurden mit faseroptischer Messtechnik ausgestattet, um eine getrennte Ermittlung der Mantel- und Spitzenwiderstände zu ermöglichen. Die aus den Messungen gewonnenen Erkenntnisse zum Lastabtragungsverhalten zeigen, dass die pfahlartigen Tragglieder aufgrund ihrer Herstellung höhere Gesamt- und insbesondere Mantelwiderstände als Schneckenortbetonpfähle, die als Referenz mit gleichem Durchmesser und gleicher Einbindelänge in identischen Baugrundverhältnissen gefertigt wurden, aufweisen. Es wird gezeigt, dass praxisübliche Bemessungsverfahren das gemessene Last-Setzungs-Verhalten nur bedingt wiedergeben. Die Versuchsergebnisse stellen die Grundlage für zukünftige Anpassungen der Bemessungsverfahren für pfahlartige Tragglieder dar. N2 - In addition to conventional pile foundations, rigid inclusion is often used in problematical ground conditions to satisfy the requirements of serviceability and stability for the foundation of structures. In order to gain knowledge about the load-bearing behaviour of the columns, test loads were carried out. Static and dynamic test loads were applied. The rigid inclusion were equipped with fibre-optic measurement technology to enable separate determination of the shaft and base resistances. The information gained from the measurements on the load transfer behaviour shows that the rigid inclusion have higher total resistances and in particular shaft resistances than auger piles, which were manufactured as reference with the same diameter and the same tie in length in identical ground conditions. It is shown that common design methods only partially reflect the measured load-settlement behaviour. The test results are the basis for future adjustments of the design methods for rigid inclusion. T2 - Determination of the bearing capacity from pile load tests on rigid inclusions Y1 - 2020 U6 - https://doi.org/10.1002/gete.202000030 VL - 43 IS - 4 SP - 298 EP - 306 PB - Ernst & Sohn ER - TY - CHAP A1 - Zrenner, Louis A1 - Neidhart, Thomas ED - Moormann, Christian ED - Vogt-Breyer, Carola T1 - Modellierung der gekoppelten thermischen und hydraulischen Transportprozesse in ZFSV-Bettungen bei erdverlegten Höchstspannungsleitungen T2 - 13. Kolloquium Bauen in Boden und Fels: Fachtagung über aktuelle Herausforderungen der Geotechnik, 1. und 2. Februar 2022, Ostfildern Y1 - 2022 SN - 9783816935452 SP - 311 EP - 322 PB - expert CY - Tübingen ER - TY - CHAP A1 - Hallas, Martin A1 - Hinrichsen, Volker A1 - Neumann, Claus A1 - Tenzer, Michael A1 - Hausmann, Bruno A1 - Gross, Detlev A1 - Neidhart, Thomas A1 - Lerch, Maximilian A1 - Wiesinger, Doris T1 - Cigré Prototype Installation Test for Gas-Insulated DC Systems - Testing a Gas-Insulated DC Transmission Line (DC-GIL) for ±550 kV and 5000 A under Real Service Conditions T2 - 2020 CIGRE Session, CIGRE e-Session 48: Paris, France (virtual), 24.08.-03.09.2020 N2 - More and more generation facilities are installed far away from the load centers. Thus, long distance transmission is demanded, and with this regard DC transmission systems are of special interest. Transmission by overhead lines is a well-proven technology, but due to environmental concern and political decisions underground transmission systems are often requested. Besides DC cables, DC GIL are an interesting option. They enable transmitting high power by only one system in a small corridor only a few meters wide. GIL can be laid in a tunnel or directly buried in the soil. Meanwhile a lot of service experience has been collected with AC GIL technology, but no service experience is yet available with DC GIL. To close this knowledge gap and to investigate the long-term performance, a ±550 kV DC GIL prototype with a current carrying capacity of 5000 A is currently investigated in a HVDC test facility, both in directly buried and in above-ground installation. The test procedure follows the recommendations for long-term testing of gas-insulated systems, currently under preparation by Cigré JWG D1/B3.57. This report describes the test sample arrangements, the high-voltage and high current test equipment and the commissioning procedure for the DC GIL. It illustrates the UHF PD monitoring system installed and the method to identify possible PD defects. The investigated DC GIL is subdivided into two parts: While an above-ground installation is simultaneously stressed by voltage and DC current, a directly buried part of the DC GIL is stressed with DC current only in order to investigate soil mechanics, the temperature distribution in the GIL and in the soil as well as the performance of the backfill material. The report also presents first results gained on the directly buried arrangement for studying the soil mechanics. Y1 - 2022 U6 - https://doi.org/10.26083/tuprints-00014132 PB - CIGRE CY - Darmstadt ER - TY - CHAP A1 - Lerch, Maximilian A1 - Neidhart, Thomas A1 - Bubenicek, Michal T1 - Fibre optic instrumentation of vibro concrete columns and surrounding ground for static and dynamic load tests T2 - Zbornik Radova GEO-EXPO 2020: Proceedings - Scientific and expert conference GEO-EXPO 2020 N2 - Instrumentation of full displacement pile like elements – at Keller called as vibro concrete columns (VCC) – is practically impossible due to utilisation of heavy deep vibro technique during the production and absence of any steel reinforcement. Thanks to cooperation between Keller and Faculty of Civil Engineering of OTH Regensburg a special procedure for post-instrumentation was developed that allows for the axial strain measurement in VCC during the loading tests. The instrumentation comprises among others optical fibre components. The procedure has been deployed on a test site during static as well as dynamic load tests. There were two different types of instrumentation implemented according to art of the load tests. Further there were robust piezometers installed in the soil in advance next to the VCC that allowed for continuous pore water pressure measurements during the load tests. Purpose of the instrumentation deployed is above all to obtain data for effective design of VCC. Y1 - 2020 U6 - https://doi.org/10.35123/GEO-EXPO_2020_6 SP - 40 EP - 49 PB - Društvo za geotehniku u Bosni i Hercegovini ER - TY - CHAP A1 - Neidhart, Thomas A1 - Lerch, Maximilian A1 - Wiesinger, Doris A1 - Hallas, Martin A1 - Hinrichsen, Volker A1 - Tenzer, Michael T1 - Long-Term Tests of a DC Gas Insulated Transmission Line (DC GIL) embedded in Temporally Flowable Backfill: Soil-Mechanical and Thermic Interaction T2 - VDE Hochspannungstechnik: ETG-Fachtagung, 9. - 11. November 2020, Online-Veranstaltung N2 - At present DC transmission systems for long distance transmission are of special interest, particularly with regard to transmission systems that proved ability for directly buried installation. Some service experience has been collected with directly buried AC GIL technology, but none with directly buried DC GIL. First pilot projects with directly buried AC GIL were designed conservative regarding the mechanical GIL support and the maximum allowable current. The aim is to optimize the mechanical and thermal design of directly buried DC GIL to offer cost efficient transmission line solutions. Therefore, a ±550 kV DC GIL prototype with a current carrying capacity of 5000 A is currently investigated in a HVDC test facility, both in above-ground installation and a buried installation. This report presents results gained on the embedded installation for studying the soil mechanics and long-term thermic interaction with the backfill material and the adjacent soil. A DC GIL with a total length of 130 m is embedded in a temporarily flowable backfill (“TFB”) as re-use of the excavated soil on site, which minimizes transportation costs and energy use. TFB is characterized by high contact forces that restrain the DC GIL displacements and by stable thermal conductivity, which optimizes the heat transfer. In order to monitor the mechanical soil-structure-interaction (“SSI”), various temperatures and moisture content sensors were installed inside and around the DC GIL, in the TFB and the adjacent soil as well down to 4 m below the ground surface. Displacement and strain sensors measured the elongations and dilatations of the embedded enclosure tube. Compressive stresses caused by restrained displacements are monitored with load cells. A fiber optical cable is used to monitor the temperatures in the aluminum conductor, on top and at the base of the enclosure tube, as well as in the TFB and the sand cover layer and the adjacent soil. The measurements were completed with some single sensors for temperature, moisture content and porewater-tensions which were mainly concentrated nearby the DC GIL in the TFB and the cover layer. During 15 months, several load cycles impact on the embedded DC GIL. Each load cycle consists of a DC current feed of 5000 A for 4 weeks followed by another 4 weeks without current. Since the SSI is independent of voltage stress, this test is carried out with current only. After 4 load cycles only moderate temperatures are monitored at the enclosure tube and in the TFB, much lower as expected. Seasonal effects predominate the temperatures of the TFB, the cover layer and the adjacent soil, while the DC GIL generates only marginal increases. Moisture contents and porewater-tensions remain constant apart from some variations caused by rainfalls and vegetation cover. The elongation of the enclosure tube is shorter than 5 mm and the forces are lower than 500 kN. It can be concluded that the DC GIL with a current carrying capacity of 5000 A DC embedded in TFB shows temperature-rises far below the technical GIL limits after 4 load cycles. The TFB ensures high and stable heat conductivity and contact forces, thus restraining the GIL movement. The temperature-rises of the natural soil due to GIL heating are comparatively low in comparison to other effects like sun radiation. The TFB shows a good thermal and mechanical performance. KW - Aluminiumleiter KW - Dauertest KW - Deckschicht KW - Dilatation KW - Energienutzung KW - Erdaushub KW - Erdoberfläche KW - Gelände KW - Gleichstromübertragung KW - Installation KW - Kontaktkraft KW - Lastwechsel (Lastspiel) KW - Pilotprojekt KW - Prüfanlage KW - Regen KW - Strahlung KW - thermische Leitfähigkeit KW - Tragfähigkeit KW - Übertragungsleitung KW - Vegetation KW - Verfüllmaterial KW - Wärmeübertragung KW - Wiederverwendung Y1 - 2020 UR - http://www.vde-verlag.de/proceedings-de/455353085.html SN - 978-3-8007-5353-6 SP - 518 EP - 524 PB - VDE-Verlag CY - Berlin ET - CD-ROM ER - TY - JOUR A1 - Wagner, Bernd A1 - Neidhart, Thomas T1 - Prognose der Druckfestigkeitsentwicklung von ZFSV : Vorschlag zweier Methoden JF - Euroheat & Power Y1 - 2016 SN - 0949-166X VL - 45 IS - 1/2 SP - 35 EP - 39 PB - VDE Verlag ER - TY - CHAP A1 - Koch, H. A1 - Imamovic, D. A1 - Lutz, B. A1 - Neidhart, Thomas A1 - Rogler, R.-D. T1 - High power underground transmission for HV DC T2 - CIGRE Session 46 : from 21 till 26 August 2016 Y1 - 2016 UR - https://cigre.es/wp-content/uploads/2016/08/call-for-papers.pdf PB - CIGRÉ CY - Paris ET - 1 DVD-ROM ER - TY - JOUR A1 - Wagnar, B. A1 - Neidhart, Thomas A1 - Siedentopf, W. A1 - Weidlich, Ingo A1 - Schleyer, A. T1 - Project in the Europaviertel in Frankfurt: Extensometer measurement technique for the quality assurance of the district heating pipelines embedded in temporarily fluid self-compressing construction filling materials JF - Euroheat and Power/Fernwärme International T2 - Projekt im Europaviertel Frankfurt: Extensometermesstechnik zur Qualitätssicherung der in ZFSV gebetteten Fernwarmeleitungen Y1 - 2013 UR - https://www.scopus.com/authid/detail.uri?authorId=55875881100#disabled VL - 42 IS - 12 SP - 35 EP - 39 ER - TY - JOUR A1 - Wagner, Bernd A1 - Neidhart, Thomas A1 - Weidlich, Ingo T1 - Initial findings of the research project: Contact behavior of temporarily fluid, self-compacting backfilling materials and HDPE JF - Euroheat and Power/Fernwärme International T2 - Erste Erkenntnisse des Forschungsvorhabens: Kontaktverhalten von zeitweise fließfähigen, selbstverdichtenden Verfüllbaustoffen und PEHD Y1 - 2013 VL - 42 IS - 10 SP - 26 EP - 29 ER - TY - CHAP A1 - Gömmel, Roland A1 - Spirkl, Florian A1 - Neidhart, Thomas T1 - Nachweis der Gesamtstandsicherheit geotechnischer Strukturen mit verschiedenartigen pfahlartigen Traggliedern T2 - Bauen in weichen Böden: Besondere Herausforderungen in Planung und Ausführung; Beiträge zum 36. Christian Veder Kolloquium : 28. und 29. Juni 2022, Graz T2 - NAWI Graz Geocenter ; Heft 11 Y1 - 2022 SP - 165 EP - 181 PB - Technische Universität Graz CY - Graz ER - TY - GEN A1 - Spirkl, Florian A1 - Neidhart, Thomas T1 - Vergleichende CO2-Bilanzierung von Rohrgrabenverfüllungen mit Sand und ZFSV KW - CO2-Bilanzierung KW - Rohrgrabenverfüllung KW - Bettungsmaterial KW - ZFSV Y1 - 2023 VL - 2023 ER - TY - CHAP A1 - Lerch, Maximilian A1 - Neidhart, Thomas ED - Stahlmann, Joachim ED - Hinzmann, Nils ED - Stein, Philipp ED - Gattermann, Jörg T1 - Messtechnische Ausrüstung von Betonstopfsäulen bei Probebelastungen T2 - Messen in der Geotechnik 2020, Fachseminar am 20./21. Februar 2020 in Braunschweig N2 - Die Ausrüstung vollverdrängter pfahlartiger Elemente – bei Keller Betonstopfsäulen (BSS) genannt – mit Messtechnik ist während der Herstellung wegen des Einsatzes schwerer Rütteltechnik und fehlender Stahlbewehrung praktisch unmöglich. In Zusammenarbeit von Keller und der Fakultät Bauingenieurwesen der Ostbayerischen Technischen Hochschule Regensburg wurde ein Verfahren zur nachträglichen Installation der Messtechnik entwickelt, das axiale Dehnungsmessungen in den BSS während der Probebelastungen ermöglicht. Die Ausrüstung besteht u. a. aus faseroptischen Komponenten. Das Verfahren wurde in situ an 1:1 Versuchen auf einem Testfeld sowohl bei statischen als auch dynamischen Probebelastungen umgesetzt. Es wurden zwei unterschiedliche Messtechniken gemäß der jeweiligen Art der Probebelastungen eingesetzt. Daneben wurden robuste Piezometer in den Boden eingebracht, die kontinuierliche Porenwasserdruckmessungen nahe der Säulen ermöglichen. Zweck der verwendeten Messtechnik war es vor allem belastbarere Ergebnisse für effektive Bemessungen der Stopfsäulen zu liefern. KW - Acceleration KW - Ausrüstung KW - Baugrund KW - Bauverfahren KW - Bayern KW - Bemessung KW - Beschleunigung KW - Bodenaufbau KW - Bohrloch KW - Bohrpfahl KW - bore pile KW - bore-hole KW - Bundesrepublik KW - compacted column foundation KW - construction method KW - cycle KW - Dehnungsmessung KW - design KW - Deutschland KW - driving KW - driving rod KW - Drucksondierung KW - equation KW - equipment KW - Extensometer KW - Faseroptik KW - Faserverbund KW - fiber optic KW - frequency range KW - Frequenzbereich KW - Gleichung KW - ground KW - grouting technology KW - in-situ concrete pile KW - in-situ test KW - In-Situ-Versuch KW - measuring KW - Messtechnik KW - normal force KW - Normalkraft KW - Ortbetonpfahl KW - penetration testing KW - Piezometer KW - pore (water) pressure KW - Porenwasserdruck KW - preliminary test KW - Probebelastung KW - Rammsonde KW - Rammung KW - Regensburg KW - Sensor KW - soil structure KW - Stopfsäule KW - strain measurement KW - test loading KW - Verpresstechnik KW - Vorversuch KW - Zyklus Y1 - 2020 SN - 978-3-948141-02-8 U6 - https://doi.org/10.24355/dbbs.084-201912181435-0 VL - 110 SP - 275 EP - 296 PB - Selbstverlag CY - Braunschweig ER - TY - JOUR A1 - Spirkl, Florian A1 - Wittl, Theresa A1 - Neidhart, Thomas T1 - Kohlendioxid-Bilanzierung: Rohrgrabenverfüllung mit Sand vs. ZFSV JF - Korrespondenz Abwasser, Abfall N2 - Als Alternative zur konventionellen Bettung von Leitungen und Rohren in Sand werden immer häufiger Zeitweise fließfähige, Selbstverdichtende Verfüllbaustoffe (ZFSV) verwendet. Die Bettung in ZFSV kann zu einer Zeit- und Kostenersparnis führen. In diesem Beitrag wird gezeigt, dass die Verwendung von ZFSV zur Rohrgrabenverfüllung gegenüber der konventionellen Sandbettung neben der Schonung der natürlichen Ressourcen zusätzlich ein Einsparpotenzial bezüglich der Treibhausgasemissionen aufweist. Y1 - 2024 U6 - https://doi.org/10.3242/kae2024.04.004 VL - 71 IS - 4 SP - 294 EP - 299 PB - GFA CY - Hennef ER - TY - CHAP A1 - Pfahler, Katharina A1 - Thiel, Charlotte A1 - Neidhart, Thomas T1 - Einfluss der Probengeometrie auf die Mechanischen Eigenschaften von Stampflehm - Eine Literaturrecherche T2 - ce/papers - Proceedings in Civil Engineering N2 - Der Klimawandel lenkt den Fokus im Bauwesen zunehmend auf die Reduktion von Treibhausgasen und die Förderung nachhaltiger Materialien. Baustoffe wie Lehm gewinnen dank ihrer ökologischen und bauphysikalischen Vorteile an Bedeutung. Eine zentrale Herausforderung stellt die Definition standardisierter Prüfmethoden für Stampflehm dar. Dieser Beitrag analysiert Forschungsergebnisse zur Geometrie von Stampflehmprobekörpern mittels Literaturrecherche und vergleicht experimentelle Untersuchungen sowie relevante Normen und Testmethoden. Die Auswertung zeigt, dass äußere Einflüsse wie Mischungszusammensetzung, Verdichtungsenergie, Gesteinskörnung und Tonminerale eine zentrale Rolle spielen. Eine Vereinheitlichung von Probengeometrie, Lagerung und Prüfverfahren ist essenziell, um reproduzierbare Ergebnisse zu erzielen und die mechanischen Kennwerte von Stampflehm vergleichbar zu machen. Ziel ist es, einheitliche Standards zu entwickeln, um die Stampflehmbauweise in der Praxis zu fördern. KW - Lehmbau KW - Stampflehm KW - Stampflehm Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-80291 SN - 2509-7075 N1 - Corresponding author der OTH Regensburg: Katharina Pfahler VL - 8 IS - 1 SP - 57 EP - 68 PB - Ernst & Sohn, a Wiley Brand ER - TY - GEN A1 - Pfahler, Katharina A1 - Neidhart, Thomas A1 - Hüttner, Susanne A1 - Thiel, Charlotte T1 - Vom Boden zur Wand - Stand der Technik und zukünftige Entwicklungen T2 - LEHM 2024, 9. Internationale Fachtagung für Lehmbau, 27.–29.9.2024, Weimar N2 - Lehm selbst ist ein Baustoff mit zahlreichen Vorteilen (diffusionsoffen, wiederverwendbar, hohe Verfügbarkeit, geringe graue Emissionen, guter Schallschutz und hohe Dauerhaftigkeit bei fachgerechtem Einsatz), aber auch Grenzen in der Anwendbarkeit, die sich aus Schwund, begrenzter Lastaufnahme und hoher Wärmeleitfähigkeit (und damit geringer Wärmedämmwirkung) ergeben. Aus Lehm und damit aus Boden Wandbaustoff zu fertigen, funktioniert sowohl im Bereich des Trockenausbaus (Lehmbauplatten, Lehmputz) als auch des tragendes Mauerwerks sehr gut und gewinnt durch die kürzlich eingeführten Normen an neuem Aufschwung. Die tragende Stampflehmbauweise mit lokal ausgehobenem Material ist bedingt durch den hohen handwerklichen Aufwand bei gleichzeitigem Fachkräftemangel und erforderlichen Zustimmung im Einzelfall oder vorhabensbezogener Bauartgenehmigung kosten- und zeitintensiv. Dabei bringt sie bauphysikalisch und ökologisch häufig signifikante Vorteile im Vergleich zu konventionellen Bauweisen mit sich. Dieser Beitrag stellt daher anhand einer ausführlichen Literaturrecherche und eigenen Versuchen den Stand der Technik industrieller Lehmbaustoffe dar. Fokus des Beitrags liegt auf Möglichkeiten, die Stampflehmbauweise zu neuer und wirtschaftlicher Leistungsfähigkeit zu bringen. KW - Lehmbau KW - Lehmbau Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-78400 SN - 978-3-00-079502-2 PB - Eigenverlag Dachverband Lehm e.V. CY - Weimar ER - TY - CHAP A1 - Ried, Michael A1 - Neidhart, Thomas ED - Rackwitz, Frank T1 - Bodenverklebungen - wie elektrische Ströme das Adhäsionsverhalten bindiger Böden beeinflussen T2 - Vorträge zum 18. Hans Lorenz Symposium; 12.09.2024, Berlin N2 - In der Bauausführung und Maschinentechnik sieht man sich immerwährend mit Haft- und Reibkräften zwischen Stahloberflächen und bindigen Böden konfrontiert. Im (Spezial-)tiefbau und auch im Tunnelbau führt die Adhäsionsneigung bindiger Böden an Aushubwerkzeugen zu massiven wirtschaftlichen Einbußen der jeweiligen Baumaßnahme und ist mit großem energetischem Aufwand für die Reinigung der Werkzeuge verbunden. In den vergangenen Jahren wurde über den Einsatz eines elektrischen Gleichspannungsfeldes eine vielversprechende Lösung diskutiert. In den ersten labortechnischen Untersuchungen konnte dabei ein Zusammenhang von elektrischen Gleichspannungsfeldern und Scher- und Zugwiderständen zwischen Stahloberflächen und bindigen Böden herausgearbeitet werden. Vor dem Hintergrund der Vorbehalte gegenüber elektrischen Strömen wurde innerhalb dieser vorgestellten Arbeit die Stromstärke auf ein Minimum reduziert. Es sollte unter definierten Rahmenbedingungen der minimal nötige Stromfluss herausgefunden werden, unter dem der gewünschte Effekt einer Adhäsionsreduktion eintritt. Bisher wurden ausschließlich die Effekte an der Kathode untersucht, ergänzend hierzu wurde in einer ersten Analyse der Einfluss des elektrischen Stroms auf die Scher- und Zugwiderstände an der Anode qualifiziert. KW - Elektroosmose (electroosmosis), Elektrokinetik (electrokinetics), Adhäsion (adhesion), Ton (clay), bindiger Boden (cohesive soil), Verklebung (clogging), Scherwiderstand (shear resistance) Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-83847 ER - TY - JOUR A1 - Gömmel, Roland A1 - Neidhart, Thomas A1 - Rackwitz, Frank T1 - Ein Ansatz zur Berücksichtigung pfahlartiger Tragglieder beim Nachweis der Gesamtstandsicherheit JF - geotechnik N2 - Stabilisierungssäulen (StS) sind hydraulisch gebundene, pfahlartige Tragglieder und werden zur Reduzierung von Setzungen bzw. zur Erhöhung der Gesamtstandsicherheit angewandt. Aufgrund der fehlenden Bewehrung in Verbindung mit häufig geringen Durchmessern sind StS nicht zum planmäßigen Abtrag von Einwirkungen quer zur Traggliedachse geeignet. Der Beitrag erläutert das laterale Tragverhalten unbewehrter pfahlartiger Tragglieder. In einem Überblick werden typische Ansätze zur Berücksichtigung von StS beim Nachweis der Gesamtstandsicherheit vorgestellt und es wird herausgearbeitet, dass die bestehenden Ansätze den Beitrag der Tragglieder meist unzutreffend berücksichtigen und häufig erheblich überschätzen. Es wird ein numerisches Strukturmodell vorgestellt, mit welchem das laterale Tragverhalten unbewehrter, hydraulisch gebundener, pfahlartiger Tragglieder untersucht wurde. Anhand systematischer Untersuchungen wird dargelegt, wie StS bei lateralen Gleitkörperbewegungen versagen und welche Versagensmechanismen zu erwarten sind. Die Aktivierung des Traggliedquerwiderstands wird für undrainierte Bedingungen anhand eines einfachen mechanischen Modells erläutert und es werden daraus grundsätzliche Hinweise zu Entwurf und Bemessung geotechnischer Konstruktionen mit StS abgeleitet. Schließlich werden zwei Ansätze zur Berücksichtigung von StS beim Nachweis der Gesamtstandsicherheit im Gleitkreisverfahren nach Bishop vorgestellt und deren Anwendung anhand eines Schadensfalls aufgezeigt. T2 - Consideration of rigid inclusions at the proof of overall-stability KW - Stabilisierungssäulen KW - Versagensmechanismen KW - Querwiderstand KW - Böschungsbruch KW - Gleitkreisverfahren Y1 - 2021 U6 - https://doi.org/10.1002/gete.202100001 SN - 2190-6653 VL - 44 IS - 4 SP - 234 EP - 247 PB - Ernst & Sohn, a Wiley Brand CY - Berlin ER - TY - CHAP A1 - Appel, Silke A1 - Henke, Sascha A1 - Rackwitz, Frank A1 - Neidhart, Thomas A1 - Gömmel, Roland A1 - Hempel, Markus T1 - Minderung der Erschütterungsemissionen aus Schienenverkehr durch den Einsatz eines innovativen Geoverbundstoffes T2 - 9. Geokunststoffkolloquium, Naue, 12. + 13. Februar 2015, Espelkamp-Fiestel Y1 - 2015 ER - TY - BOOK A1 - Reichenbach, Hartmut A1 - Bruss, Werner A1 - Bürger, Michael A1 - Fiedler, Manfred A1 - Göbel, Manuel A1 - Middendorf, Bernhard A1 - Neidhart, Thomas A1 - Pollnow, Elke A1 - Ramler-Kowollik, Marcel A1 - Scholz, Enrico A1 - Simon, Jana A1 - Sosinka, Katharina A1 - Spirkl, Florian A1 - Trunk, Ulrich A1 - Wagner, Achim A1 - Wagner, Bernd A1 - Weber, Steffen ED - Forschungsgesellschaft für Straßen- und Verkehrswesen FGSV e.V., T1 - Merkblatt für die Herstellung und Verwendung von zeitweise fließfähigen, selbstverdichtenden Verfüllbaustoffen (ZFSV) im Erdbau N2 - Das „Merkblatt für die Herstellung und Verwendung von zeitweise fließfähigen, selbstverdichtenden Verfüllbaustoffen“ (M ZFSV), Ausgabe 2025, befasst sich mit der Herstellung und der Anwendung zeitweise fließfähiger, selbstverdichtender Verfüllbaustoffe (ZFSV) gemäß den „Zusätzlichen Technischen Vertragsbedingungen und Richtlinien für Erdarbeiten im Straßenbau“ (ZTV E-StB) (FGSV 599) beim Bau von Straßen und Verkehrsflächen. Für andere Bereiche des Bauwesens kann dieses Merkblatt ebenfalls angewendet werden. Das M ZFSV enthält Qualitätsanforderungen für diese Baustoffe und Baustoffgemische. Die Anforderungen schließen die verschiedenen Anwendungsgebiete der Baustoffe und Baustoffgemische, die Herstellung, Lieferung und den Einbau sowie die Prüfungen und die Qualitätssicherung ein. Vorab wird ebenso auf Anwendungsgebiete und Planungsgrundsätze eingegangen. Ergänzt werden die umfangreichen Ausführungen durch mehrere Anhänge. Y1 - 2025 SN - 978-3-86446-419-5 PB - FGSV Verlag CY - Köln ET - Ausgabe 2025 ER - TY - RPRT A1 - Banning, Timo Che A1 - Büschken, Sven A1 - Gabriel, Eugen A1 - Hay, Stefan A1 - Neidhart, Thomas A1 - Ried, Michael A1 - Spirkl, Florian A1 - Wagner, Bernd A1 - Weidlich, Ingo A1 - Zrenner, Louis T1 - EnEff:Wärme - FW-ZFSV 4_0 - Fernwärmeleitungsbau 4.0 mit zeitweise fließfähigen selbstverdichtenden Verfüllbaustoffen für niedrige und hohe Betriebstemperaturen : Abschlussbericht zum Verbundforschungsvorhaben T2 - Forschung & Entwicklung N2 - Das dem Heft 68 zugrunde liegende Forschungsvorhaben „EnEff:Wärme: FW-ZFSV_4-0 - Fernwärmeleitungsbau 4.0 mit zeitweise fließfähigen selbstverdichtenden Verfüllbaustoffen für niedrige und hohe Betriebstemperaturen“ (FW-ZFSV 4.0) wurde im Rahmen des 7. Energieforschungsprogramms „Innovationen für die Energiewende“ vom Bundeswirtschaftsministerium für Energie und Klimaschutz über den Projektträger Jülich bewilligt und gefördert (FKZ 03EN3022). Die Bearbeitung erfolgte in einem Verbund aus AGFW-Projektgesellschaft für Rationalisierung, Information und Standardisierung mbH, der GEF Ingenieur AG, Leimen, der Ostbayerische Technische Hochschule Regensburg - Fakultät Bauingenieurwesen - Labor für Geotechnik, Regensburg und der HafenCity Universität Hamburg, Hamburg. Ziel des Vorhabens FW-ZFSV 4.0 war es, für den Bereich der Fernwärme Hemmnisse aufzugreifen, praktisch und angewandt zu untersuchen und Antworten auf Fragen zu liefern, die in der Planung und Praxis noch den Einsatz der technisch für den Fernwärmeeinsatz gut erforschten ZFSV als Alternative zur üblichen Verfüllung und Bettung mit Sand verhindern. Darunter fällt insbesondere die Absicherung des Langzeitverhaltens durch Untersuchungen in situ, die Ermöglichung der EDV-gestützten statischen Berechnung sowie die Beantwortung offener organisatorischer und genehmigungsrechtlicher Fragen. Mit den ausführlich dargestellten Projektergebnissen zu den oben genannten Themen sowie darüber hinaus ist es zukünftig möglich, ZFSV im Fernwärmeleitungsbau stark vereinfacht und sicher einzusetzen. Aus Sicht des Projektkonsortiums steht mit ZFSV ein weiteres, generell abgesichertes Bettungsverfahren für insbesondere Kunststoffmantelrohre (als dominierendes System in der Fernwärme) als Alternative zur Verfüllung mit Sand zur Verfügung, das in Zukunft hoffentlich umfangreiche Anwendung findet. Gleichzeitig wird damit und dadurch den allgemein bekannten Potenzialen von ZFSV bei der Bautechnik, der möglichen Kostenreduktion, der Reduktion des Einflusses von Baumaßnahmen auf Umgebung und Umwelt sowie bei der Ressourcenschonung weiter der Weg in der netzgebundenen Wärmeversorgung bereitet. Dies ist auch von erheblicher Bedeutung, da sich während der Projektlaufzeit gezeigt hat, dass sich die Anforderungen der Kreislaufwirtschaft an die Zulässigkeit natürlicher Rohstoffe wie Sand als Verfüllmaterial (Stichwort: Ersatzbaustoffverordnung) sowie die Konkurrenz um Sand als Rohstoff aktuell und zukünftig verschärfen. KW - ZFSV KW - Zeitweise fließfähige selbstverdichtende Verfüllbaustoffe KW - Fernwärme KW - Wärmewende KW - Nachhaltigkeit Y1 - 2025 SN - 3-89999-107-9 IS - 68 PB - AGFW e.V. CY - Frankfurt am Main ER - TY - CHAP A1 - Ried, Michael A1 - Piechullek, Amelie A1 - Neidhart, Thomas ED - Marte, Roman ED - Tschuchnigg, Franz T1 - Elektrotechnik und Geotechnik in bodenphysikalischer Symbiose zur Beeinflussung der Wasserverhältnisse in bindigen Böden T2 - Beiträge zum 39. Christian Veder Kolloquium - Wasser in der Geotechnik: Herausforderungen und Lösungen N2 - Im Gegensatz zu nichtbindigen Böden sind die bodenphysikalischen und im Besonderen die bodenmechanischen Eigenschaften bindiger Böden direkt vom Wassergehalt in situ abhängig. Der Wassergehalt bestimmt die Konsistenz des Bodens, die Scherfestigkeit und damit auch die Mantelreibung geotechnischer Tiefbauwerke. Daneben wird das Setzungsverhalten von auf bindigen Böden gegründeten Bauwerken maßgeblich durch das Porenwasser bestimmt. Vor dem Hintergrund der wassergehaltsabhängigen Eigenschaften ist es regelmäßig von Interesse das Wasser im bindigen Boden zu beeinflussen. Durch die kleinen Kapillardurchmesser und die Oberflächenladung der Silikatschichten bindiger Böden ist es möglich über elektrische Felder auf das Porenwasser des Bodens effektiv einzuwirken. Bereits in der Mitte des 20. Jahrhunderts wurde versucht, durch elektrische Ströme Konsolidationsprozesse anzustoßen (Cassagrande, 1949). Darauf aufbauend stellte der Namensgeber dieses Kolloquiums Christian Veder in den 1970er Jahren mit seinem Kollegen Hilbert verschiedene Ansätze zu den an Hangrutschungen beteiligten elektrokinetischen Prozessen und deren Nutzbarmachung zur Stabilisierung vor. Durch die Elektroosmose in den Kapillaren bindiger Böden oder Böden mit bindigem Anteil führt das elektrische Gleichspannungsfeld zu einer Wassermigration von Anode zu Kathode. Der Wassergehalt an der Anode nimmt daher ab und an der Kathode nimmt er zu. So lässt sich die wassergehaltabhängige Konsistenz sowie die Scherfestigkeit des Bodens gezielt verändern (Veder & Hilbert, 1979). Durch die starke Abhängigkeit der Feinkornminerale von den zur Verfügung stehenden Ionen wird der Boden durch ein elektrisches Feld nicht nur in seiner Zustandsform beeinflusst, sondern auch in seiner Bodenphysik. Die hier vorzustellenden Untersuchungen sollten die Erkenntnisse vertiefen und das Anwendungsspektrum elektrischer Ströme im Boden erweitern. Der Fokus lag hierbei auf der elektrokinetischen Porenwassermanipulation und deren Einfluss auf die mechanische Interaktion (Haftreibung und Haftzugfestigkeit) zwischen bindigen Böden und Festkörperoberflächen. KW - Elektroosmose (electroosmosis) KW - Elektrokinetik (electrokinetics) KW - Konsolidation (consolidation) KW - Porenwasser (pore water) KW - Ionenhaushalt (ion household) Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-85452 SN - 978-3-903613-00-3 VL - Heft 21 PB - Nawi Graz Geocenter CY - Graz ER - TY - GEN A1 - Ried, Michael A1 - Neidhart, Thomas T1 - Electrical-and geotechnical engineering in soil physical symbiosis to influence the water conditions of cohesive soils N2 - In contrast to non-cohesive soils, the soil physical and, in particular, the soil mechanical properties of cohesive soils are directly dependent on the in-situ water content. The water content determines the consistency of the soil, the shear strength, and thus also the skin friction of geotechnical deep foundations. Furthermore, the settlement behavior of structures founded on cohesive soils is significantly influenced by the pore water. Given these water content-dependent properties, it is frequently of interest to influence the water content in cohesive soil. Due to the small capillary diameters and the surface charge of the silicate layers in cohesive soils, it is possible to effectively influence the pore water of the soil using electric fields. As early as the mid-20th century, attempts were made to initiate consolidation processes using electric currents (Casagrande, 1949). Building on this, Christian Veder, the namesake of this colloquium, and his colleague Hilbert presented various approaches in the 1970s regarding the electrokinetic processes involved in landslides and their utilization for stabilization. Due to electroosmosis in the capillaries of cohesive soils or soils with a cohesive component, the direct current electric field leads to water migration from the anode to the cathode. The water content at the anode therefore decreases, while it increases at the cathode. In this way, the water content-dependent consistency and shear strength of the soil can be specifically altered (Veder & Hilbert, 1979). Due to the strong dependence of the fine-grained minerals on the available ions, the soil is influenced by an electric field not only in its state but also in its soil physics. The investigations presented here aimed to deepen these insights and expand the range of applications of electric currents in soil. The focus was on electrokinetic pore water manipulation and its influence on the mechanical interaction (adhesion and tensile strength) between cohesive soils and solid surfaces. KW - Elektroosmose (electroosmosis) KW - Elektrokinetik (electrokinetics) KW - Konsolidation (consolidation) KW - Porenwasser (pore water) KW - Ionenhaushalt (ion household) Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-85461 VL - 2025 CY - Regensburg ER - TY - CHAP A1 - Ried, Michael A1 - Neidhart, Thomas ED - Moormann, Christian ED - Vogt-Breyer, Carola T1 - Untersuchung elektroosmotischer Effekte auf Adhäsion und Gleitreibung eines bindigen Modellbodens: ein elektrisches Gleichspannungsfeld zur Veränderung der Mechanik zwischen Boden und Stahl T2 - 14. Kolloquium Bauen in Boden und Fels: Fachtagung über aktuelle Herausforderungen der Geotechnik, 30. + 31. Januar 2024, Esslingen N2 - In der Bauausführung und Maschinentechnik sieht man sich immerwährend mit Haft- und Reibkräften zwischen Stahloberflächen und bindigen Böden konfrontiert. Im (Spezial-)tiefbau und auch im Tunnelbau führt die Adhäsionsneigung bindiger Böden an Aushubwerkzeugen zu massiven wirtschaftlichen Einbußen der jeweiligen Baumaßnahme und ist mit großem energetischem Aufwand für die Reinigung der Werkzeuge verbunden. In den vergangenen Jahren wurde über den Einsatz eines elektrischen Gleichspannungsfeldes mehrfach eine vielversprechende Lösung diskutiert. Die durch den elektroosmotischen Effekt hervorgerufene Wasserdiffusion hin zur positiv geladenen Kathode führt zu einer signifikanten Reduktion der Adhäsion zwischen Stahloberfläche und bindigem Boden. Dabei wird die Haftspannung tangential wie auch senkrecht zur Werkzeugoberfläche durch elektrische Ströme beeinflusst. Innerhalb dieser vorgestellten Arbeit wurde ein Rotationsscherversuch entwickelt, mit dem die elektroneninduzierte Veränderung der mechanischen Interaktion zwischen Boden und Stahloberfläche systematisch untersucht und quantifiziert wurde. KW - Elektroosmose (electroosmosis), Elektrokinetik (electrokinetics), Adhäsion (adhesion), Ton (clay), bindiger Boden (cohesive soil), Verklebung (clogging), Scherwiderstand (shear resistance) Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-83839 SN - ISBN 978-3-381-11811-3 SP - 145 EP - 155 PB - expert CY - Tübingen ER - TY - GEN A1 - Ried, Michael A1 - Neidhart, Thomas T1 - Was lange währt ist auch gut: Langzeitverhalten von ZFSV BT - Anhand der Forschungsmessstrecke „Bypassleitung“ im Europaviertel in Frankfurt am Main N2 - Vollständige Prozessbegleitung alternativer bindemittelversetzter Bettungsmaterialien im Fernwärmeleitungsbau über Eignungsprüfung, Qualitätskontrolle, Statik KW - ZFSV (Zeitweise fließfähiger selbstverdichtender Verfüllbaustoff) KW - Fernwärme (district heating) KW - Eignungsprüfung (suitability test) KW - plastic concrete KW - Festigkeit (strength) Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-85536 VL - 2025 CY - Regensburg ER - TY - GEN A1 - Spirkl, Florian A1 - Neidhart, Thomas T1 - Environmental advantages and recycling potential of temporarily flowable backfill as bedding material for district heating pipes T2 - 19th International Symposium on District Heating and Cooling, 07-10. September 2025, Genk, Belgium N2 - District heating networks are a key to a successful transformation towards climate neutrality. Typically, District Heating Pipes (DHP) are embedded in coarse sand with specific grain size distributions and soil properties. An alternative to this are the temporarily flowable backfill materials (TFB). These are a mixture of aggregate, binder (e.g. cement), water and, if necessary, additional supplements, e.g. bentonite. TFB can be mixed-on-site or mixed-in-plant, depending on the boundary conditions. Where possible, the excavated soil is used as aggregate. This paper will look at possible environmental advantages as part of a life cycle assessment, especially regarding the carbon footprint, if TFB is used in place of typical sand bedding. A total of 7 environmental impact factors are compared as part of a case study. As there are a multitude of variables with widely ranging impact for the calculation of the environmental impact, an additional sensitivity study was performed, to determine key parameters for the carbon footprint. In a multitude of cases, it can be shown that TFB has a smaller carbon footprint compared to sand bedding, as the number of transports can be greatly reduced and the TFB doesn’t need to be compacted. These factors predominate the need of cement, which is negatively connoted regarding the environmental impact. If the excavated soil is not eligible as an aggregate for TFB, an alternative base component is necessary. Typically, mixed-in-plant-produced TFB uses sand, as the properties of TFB based on recycling materials has hardly been investigated. In order to conserve natural resources and at the same time recycle construction waste, investigations were carried out into the production and strength behavior of TFB made from different construction materials. The main goal was to mix TFB which is easily re-excavated, as per German guideline H ZFSV. This was achieved with every recycling material, but with varying amount of cement necessary. As part of a long-term study, a delayed increase in strength depending on the source material could be shown. This is due to pozzolanic reactions. Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-85111 ER - TY - INPR A1 - Spirkl, Florian A1 - Neidhart, Thomas T1 - Nachhaltige Bauverfahren durch Verwendung des anstehenden Bodens am Beispiel von Dichtwänden und Rohrgrabenverfüllung N2 - Der „Earth Overshoot Day“ verdeutlicht, dass wir zu viele Ressourcen verbrauchen und es immer noch großen Handlungsbedarf gibt, um nicht weiterhin auf Kosten zukünftiger Generationen zu leben. Dabei spielt der Bausektor eine große Rolle, entstehen hier doch ein erheblicher Anteil der deponierten Abfälle (ca. 55 % in DE), der CO2-Emissionen (ca. 36 % in der EU) und des Energieverbrauchs (ca. 40 % in der EU). Ein „Weiter so“ wie bisher ist unter diesen Aspekten nicht zielführend. Es braucht daher innovative Ansätze für Baustoffe, Bauprodukte und Bauweisen. Im Beitrag wird aufgezeigt, wie durch innovative Ansätze der Bausektor nachhaltiger gestaltet werden kann. Dies erfolgt anhand zweier Beispiele, bei der eine Dichtwand und eine Rohrgrabenverfüllung betrachtet werden. Zunächst wird am Beispiel der Dichtwand der CO2-Fußabdruck einer klassischen Dichtwand, hergestellt als Spundwand, verglichen mit dem Verfahren der Fräsmischinjektion. Da der Baugrund selbst als Baustoff genutzt wird und kein Bohrgut anfällt, wird hierdurch im Sinne des Kreislaufwirtschaftsgesetzes „Abfall“ vermieden. Gleichzeitig entfallen hierdurch eine Vielzahl an Materialtransporten. Am Beispiel der (Rohr-)Grabenverfüllung wird aufgezeigt, wie sich unterschiedliche Innovationsgrade auf die Nachhaltigkeit eines Bauverfahrens auswirken. Hierfür wird als Ausgangssituation die Bettung und Verfüllung eines Rohrgrabens mittels Sand betrachtet. Als Alternative hierzu werden zeitweise fließfähige selbstverdichtende Verfüllbaustoffe (ZFSV) betrachtet. ZFSV werden aus einer Grundkomponente (Boden, Baustoffe, Recycling-Stoffe) hergestellt, welche mit Wasser, Bindemittel und ggf. Zusätzen versetzt werden. Durch die Erhöhung des Wassergehalts erhalten die ZFSV ihre fließfähigen selbstverdichtenden Eigenschaften. Anschließend wird das Wasser durch das Bindemittel und die ggf. verwendeten Zusätze teilweise gebunden, so dass i.d.R. bereits wenige Stunden nach der ZFSV-Verfüllung die Begehbarkeit und nach einem Tag die Überbaubarkeit gewährleistet ist. Das Bindemittel wird dabei je nach Anwendungszweck dosiert. Zur Verwendung als Bettungsmaterial von Leitungen wird i.d.R. eine zeitabhängige, maximale Druckfestigkeit des ZFSV definiert und damit auch die Menge des Bindemittels begrenzt. Meist wird ein hydraulisch abbindendes Material (z.B. Zement) verwendet. Weitere allgemeine Angaben zum Thema ZFSV finden sich z.B. in Neidhart, Spirkl (2022), Bont (2022), Ramler (2022), Wagner (2022), Wiesinger (2022). Die Herstellung von ZFSV kann in einem Werk (Mixed in Plant) oder vor Ort (Mixed on Site) geschehen. Als Ausgangsmaterial kann Sand, Recyclingmaterial oder, wenn die Eignung nachgewiesen wird, auch das Aushubmaterial vor Ort verwendet werden. Das Potenzial einer nachhaltigen Bauweise durch eine ZFSV-Bettung wird im Beitrag in 4 verschiedenen Szenarien anhand eines realen Bauprojekts in Kelheim betrachtet: 1. Verwendung von Sand-basiertem ZFSV anstelle Sand-Bettung 2. Verwendung von Recyclingmaterial-basiertem ZFSV 3. Verwendung des anstehenden Aushubmaterials zur ZFSV-Herstellung 4. Optimierung des Grabenquerschnitts und Bauablaufs Grundsätzlich wurde bereits nachgewiesen, dass die Verwendung von ZFSV als Bettungsmaterial zu einem beschleunigten Bauablauf führen kann, und die Kosten je nach Randbedingung vergleichbar zur Sand-Bettung sind. Mit den dargestellten Szenarien, deren Einfluss auf die Nachhaltigkeit der Baustelle von 1. bis 4. zunimmt, zeigt sich auch in diesem Bereich das Potenzial von ZFSV. Je nach Ausgangsmaterial und Ort der ZFSV-Herstellung kann Material (Sand) und Transporte eingespart, die zu deponierende Menge reduziert und die Ökobilanzierung im Gesamten verbessert werden. Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-85216 ER - TY - INPR A1 - Leusink, Florian A1 - Ried, Michael A1 - Spirkl, Florian A1 - Neidhart, Thomas T1 - Der dynamische CBR-Versuch : ein Festigkeitsindikator für Boden-Bindemittel-Gemische im Erd- und Tiefbau N2 - Bei der Eignungsprüfung für qualifizierte Bodenverbesserungen wird die benötigte Menge des Bindemittels mittels Anforderungen an die einaxiale Druckfestigkeit oder den CBR-Wert festgelegt. Gemäß dem Merkblatt über Bodenbehandlungen mit Bindemitteln (M BMB 2021) muss bei qualifizierten Bodenverbesserungen eine einaxiale Druckfestigkeit von mindestens 0,5 MPa bzw. ein CBR-Wert von mindestens 40 % nach 28Tagen erreicht werden. Eine Überwachung der einaxialen Druckfestigkeit ist in situ der Praxis nur schwer möglich, da die hierzu notwendige Bohrkernentnahme mit erheblichem Aufwand verbunden ist und durch die niedrige Druckfestigkeit des Boden-Bindemittel-Gemisches das Risiko besteht, dass Bohrkerne beschädigt werden oder eine Entnahme nicht möglich ist. Es gibt daher keine festgeschriebene Überwachung der einaxialen Druckfestigkeit bei der qualifizierten Bodenverbesserung, in der Praxis erfolgt die Qualitätsüberwachung meist durch eine Dichtekontrolle. Für Auftraggeber ist eine In-situ-Bestimmung der Festigkeit von besonderem Interesse, um eine zuverlässige Überwachung zu gewährleisten, gleichzeitig kann sie Auftragnehmern als Nachweis der erbrachten Qualität bei etwaigen Schäden und zur Absicherung in der Gewährleistungsphase dienen. So ermöglicht die in situ ermittelte Festigkeit den Nachweis, dass die Qualität der qualifizierten Bodenverbesserung den bei der Eignungsprüfung festgelegten Anforderungen entspricht, selbst bei variierenden Herstellungsverfahren, wechselnder Geologie und unterschiedlichen Lagerungsbedingungen. Eine regelmäßige Überwachung der In-situ-Festigkeit ist wichtig, um eine konstant hohe Qualität zu sichern. Eine alternative Methode zur Bestimmung der In-situ-Festigkeit stellt der dynamische CBR-Versuch nach TP Gestein-StB Teil 5.6 dar. Hierbei handelt es sich um einen Stempeleindringversuch, bei dem ein Stempel mit einem Durchmesser von 5 cm mithilfe einer stoßartigen Belastung durch das leichte Fallgewicht in den Boden gedrückt wird. Die hohen induzierten Spannungen von 3,60 MPa überschreiten dabei die Druckfestigkeit des Materials und führen zu einem Strukturbruch. Im Gegensatz zu statischen und dynamischen Lastplattendruckversuchen wird so die Festigkeit des Bodens abgebildet und nicht dessen Steifigkeit. In umfassenden Versuchsreihen wurden im Labor Boden-Bindemittel-Gemische hergestellt und nach 28 d an jeweils drei Teilversuchen die einaxiale Druckfestigkeit und an jeweils sechs Teilversuchen der dynamische CBR-Wert ermittelt. Zusätzlich wurden auf Baustellen dynamische CBR-Werte in situ ermittelt und Bohrkerne entnommen, um die einaxiale Druckfestigkeit im Labor zu bestimmen. Die Versuchsreihen ermöglichten es, eine Korrelation zwischen den beiden Kennwerten abzuleiten. Durch diese Korrelation kann nun anhand des in situ ermittelten dynamischen CBR-Wertes auf die einaxiale Druckfestigkeit geschlossen werden. Dies ermöglicht eine einfache Qualitätsüberwachung, die über die bloße Ermittlung der Dichte hinaus geht und mit minimalem Zeit- und Kostenaufwand verbunden ist. Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-85221 ER - TY - CHAP A1 - Ried, Michael A1 - Piechullek, Amelie A1 - Neidhart, Thomas T1 - Elektrotechnik und Geotechnik in bodenphysikalischer Symbiose zur Beeinflussung der Wasserverhältnisse in bindigen Böden T2 - Tagungsband Fachsektionstage Geotechnik N2 - Die bodenphysikalischen Eigenschaften bindiger Böden hängen direkt von dem Wassergehalt ab. Daher ist es regelmäßig von Interesse Einfluss auf die Wasserverhältnisse in bindigen Böden zu nehmen. Durch elektrokinetische Prozesse in den Kapillarporen kann der Wasserhaushalt des Bodens verändert werden. Durch neu entwickelte Laborversuche und deren Ergebnisse sollen die Anwendungsmöglichkeiten elektrokinetischer Verfahren in bindigen Böden aufgezeigt werden. So konnte gezeigt werden, dass sich die Konsolidationszeit durch eine starke Zunahme der Strö-mungsgeschwindigkeit in einem elektrischen Gleichspannungsfeld beschleunigen lässt. Es wurde zudem untersucht, wie sich der Wassergehalt und die damit verbundene Konsistenz eines Modell-bodens an Kathode und Anode verändert. KW - Elektroosmose (electroosmosis) Y1 - 2025 SN - 978-3-946039-13-6 SP - 369 EP - 374 CY - Essen ER - TY - CHAP A1 - Wagner, Bernd A1 - Hay, Stefan A1 - Neidhart, Thomas A1 - Spirkl, Florian A1 - Ried, Michael A1 - Zrenner, Louis A1 - Weidlich, Ingo A1 - Gabriel, Eugen A1 - Banning, Timo ED - Vanhoudt, Dirk T1 - TFSB as Bedding Material in District Heating Pipe Constructin - Scientifically Proven Long-Term Experience T2 - Proceedings of the 19th International Symposium on District Heating and Cooling; 2025, Genk (Belgium) N2 - Following the explanation of the increasing importance of alternative backfill materials like TFSB, TFSB and their status in terms of science and technology are depicted. Selected results of the research project FW-ZFSV 4.0 are presented: computer-aided static calculation, in situ long term loading of district heating pipes in TFSB and sand, quality assurance and resource conservation. The conclusions provide an overall assessment of the use of TFSB in district heating pipe construction. Y1 - 2026 SN - 9783032098443 U6 - https://doi.org/10.1007/978-3-032-09844-3_10 SP - 99 EP - 108 PB - Springer CY - Cham ER -