TY - RPRT A1 - Backes, Judith A1 - Balke, Maurice A1 - Benerjee, Marc A1 - Beitzel, Knut A1 - Böhm, Elisabeth A1 - Brandt, Hanna A1 - Brunner, Ulrich A1 - Büttner, Carl Christopher A1 - Dyrna, Felix A1 - Grossmann, Irmgard A1 - Gühring, Thorsten A1 - Hünnebeck, Sophia A1 - Kähler, Michael A1 - Klöckner, Nicole A1 - Kopkow, Christian A1 - Lehmann, Lars A1 - Martetschläger, Frank A1 - Mauch, Frieder A1 - Michalk, Katrin A1 - Müller, Maike A1 - Müller-Rath, Ralf A1 - Nolte, Philip A1 - Pfingsten, Andrea A1 - Prill, Robert A1 - Schnetzke, Marc A1 - Seckler, Martina T1 - Subacromiales Impingment Y1 - 2021 UR - https://register.awmf.org/assets/guidelines/033-056l_S2e_subacromiales_Impingement_2021-12_01.pdf ET - 1. Aufl./Version 1.0 (02.05.2021) ER - TY - INPR A1 - Müller, Max A1 - Weigl, Stefan A1 - Müller-Williams, Jennifer A1 - Lindauer, Matthias A1 - Rück, Thomas A1 - Jobst, Simon A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Ambient methane monitoring at Hohenpeißenberg utilizing photoacoustic spectroscopy and cavity ring down spectroscopy N2 - With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10−9) methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective, is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a five day period at Hohenpeißenberg, Germany. As a reference device a calibrated cavity ringdown spectrometer Picarro G2301 from the meteorological observatory was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to environmental influences. The obtained results show that relaxation effects due to fluctuating environmental conditions, e.g. ambient humidity, are a non-negligible factor in PA sensor systems. Applying algorithm compensation techniques, which are capable of calculating the influence of relaxational effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 % from the G2301, the photoacoustic sensor shows good agreement with the reference instrument. Y1 - 2023 U6 - https://doi.org/10.5194/egusphere-2023-1010 ER - TY - JOUR A1 - Müller, Max A1 - Weigl, Stefan A1 - Müller-Williams, Jennifer A1 - Lindauer, Matthias A1 - Rück, Thomas A1 - Jobst, Simon A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Comparison of photoacoustic spectroscopy and cavity ring-down spectroscopy for ambient methane monitoring at Hohenpeißenberg JF - Atmospheric Measurement Techniques N2 - With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10−9), methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a 5 d period at Hohenpeißenberg, Germany. As a reference device, a calibrated cavity ring-down spectrometer, Picarro G2301, from the meteorological observatory of the German Weather Service (DWD) was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to fluctuating environmental conditions, e.g. ambient humidity. The obtained results show that for PA sensor systems non-radiative relaxation effects induced by varying humidity are a non-negligible factor. Applying algorithm compensation techniques, which are capable of calculating the influence of non-radiative relaxation effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 % from the G2301, the photoacoustic sensor shows good agreement with the reference instrument. Y1 - 2023 U6 - https://doi.org/10.5194/amt-16-4263-2023 SN - 1867-8548 VL - 16 IS - 18 SP - 4263 EP - 4270 PB - Copernicus Publications ER - TY - RPRT A1 - Blößer, Julia A1 - Branilovic, Fabio A1 - Michael, Bretz A1 - Ebner, Andreas A1 - Gleich, Ralf A1 - Inderst, Christian A1 - Kopp, Lorenz A1 - Müller, Markus A1 - Schächiner, Michael A1 - von Beerfelde, Rebekka ED - Fuhrmann, Thomas ED - Niemetz, Michael ED - Reindl, Andrea T1 - FMS-Berichte Sommersemester 2024 BT - Seminar zu aktuellen Themen der Elektro- und Informationstechnik T2 - FMS-Berichte Sommersemester 2024 N2 - Dieser Bericht entstand ursprünglich auf Initiative der Studierenden des damals neuen Masterstudiengangs „Elektro- und Informationstechnik (MEI)“ an der OTH Regensburg, die an der Pflichtlehrveranstaltung „Forschungsmethoden und Seminar (FMS)“ im Wintersemester 2020/21 teilnahmen. Diese Lehrveranstaltung hat das Ziel, systematisch an das wissenschaftliche Arbeiten, speziell die Wissenschaftskommunikation, heranzuführen. Daher ist im Laufe der Veranstaltung geeignete Literatur zu einem individuellen Thema zu recherchieren, sind Veröffentlichungen auf ihre Relevanz hin zu beurteilen und letztendlich gilt es eine eigene Ausarbeitung basierend auf der Literaturrecherche zu erstellen und diese in einem Vortrag zu präsentieren. Parallel dazu wird im Theorieteil die entsprechende Hinführung zu den verschiedenen Elementen der Wissenschaftskommunikation vermittelt: • Bedeutung der Wissenschaftskommunikation für die Arbeit der Ingenieure in Forschung und Entwicklung • Literaturrecherche, Suchmaschinen, Sichtung und Analyse vorhandener Publikationen, Bewertung der Qualität aufgefundener Fachliteratur, Auswahl geeigneter Materialien für die eigene Arbeit • Aufbereitung und Darstellung der recherchierten technischer Inhalte in Form einer seitenanzahlbegrenzten wissenschaftlichen Ausarbeitung • Einhalten formaler Randbedingungen bzgl. Strukturierung, einschl. Bildnachweise und Zitationsstile • Peer-review-Prozess bei wertschätzender Beurteilung der Leistung anderer • Publikumsangepasstes Aufbereiten komplexer fachlicher Inhalte mit hochschulöffentlicher Präsentation der Ergebnisse • Führen mündlicher wissenschaftlicher Diskurse Die präsentierten Themen beruhen nicht auf eigener Forschungstätigkeit, sondern sind als einführende Reviewartikel zum jeweiligen vorgegebenen technischen oder gesellschaftspolitischen Forschungsthema zu verstehen. T3 - Forschungsmethoden-Seminar - 8 KW - Elektrotechnik KW - Informationstechnik KW - Energietechnik KW - Literaturrecherche Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-77801 IS - 1 CY - Regensburg ER - TY - JOUR A1 - Müller, Max A1 - Rück, Thomas A1 - Jobst, Simon A1 - Pangerl, Jonas A1 - Weigl, Stefan A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - An Algorithmic Approach to Compute the Effect of Non-Radiative Relaxation Processes in Photoacoustic Spectroscopy JF - Photoacoustics N2 - Successful transfer of photoacoustic gas sensors from laboratory to real-life applications requires knowledge about potential cross-sensitivities towards environmental and gas matrix changes. Multi-dimensional calibration in case of cross-sensitivities can become very complex or even unfeasible. To address this challenge, we present a novel algorithm to compute the collision based non-radiative efficiency and phase lag of energy relaxation on a molecular level (CoNRad) for photoacoustic signal calculation. This algorithmic approach allows to calculate the entire elaxation cascade of arbitrarily complex systems, yielding a theoretical photoacoustic signal. In this work the influence of varying bulk compositions, i.e. nitrogen (N2), oxygen (O2) and water (H2O) on the photoacoustic signal during methane (CH4) detection is demonstrated. The applicability of the algorithm to other photoacoustic setups is shown exemplary by applying it to the relaxational system investigated in [1]. Hayden et al. examined the effect of water on photoacoustic carbon monoxide (CO) detection. Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-39935 N1 - Corresponding author: Max Müller VL - 26 PB - Elsevier ER - TY - RPRT A1 - Steiger, Tamara A1 - Foltan, Maik A1 - Philipp, Alois A1 - Müller, Thomas A1 - Gruber, Michael A1 - Bredthauer, Andre A1 - Krenkel, Lars A1 - Birkenmaier, Clemens A1 - Lehle, Karla T1 - Accumulations of von Willebrand factor within ECMO oxygenators: Potential indicator of coagulation abnormalities in critically ill patients? N2 - Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots—in particular, the presence of von Willebrand factor (vWF)—may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti‐vWF and anti‐P‐selectin) and counterstained with 4′,6‐diamidino‐2‐phenylindole. The extent of vWF‐loading was correlated with patient and technical data. While 12 MOs showed low vWF‐loadings, 9 MOs showed high vWF‐loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF‐fibers/“cobwebs,” leukocytes, platelet–leukocyte aggregates (PLAs), and P‐selectin‐positive platelet aggregates were independent of the extent of vWF‐loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high‐molecular‐weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy. Y1 - 2019 ER - TY - JOUR A1 - Birkenmaier, Clemens A1 - Dornia, Christian A1 - Lehle, Karla A1 - Müller, Thomas A1 - Gruber, Michael A1 - Philipp, Alois A1 - Krenkel, Lars T1 - Analysis of Thrombotic Deposits in Extracorporeal Membrane Oxygenators by High-resolution Microcomputed Tomography: A Feasibility Study JF - ASAIO Journal / American Society for Artificial Internal Organs N2 - Coagulative disorders, especially clotting during extracorporeal membrane oxygenation, are frequent complications. Direct visualization and analysis of deposits in membrane oxygenators using computed tomography (CT) may provide an insight into the underlying mechanisms causing thrombotic events. However, the already established multidetector CT1 (MDCT) method shows major limitations. Here, we demonstrate the feasibility of applying industrial micro-CT (μCT) to circumvent these restrictions. Three clinically used membrane oxygenators were investigated applying both MDCT and μCT. The scans were analyzed in terms of clot volume and local clot distribution. As validation, the clot volume was also determined from the fluid volume, which could be filled into the respective used oxygenator compared to a new device. In addition, cross-sectional CT images were compared with crosscut oxygenators. Based on the μCT findings, a morphological measure (sphericity) for assessing clot structures in membrane oxygenators is introduced. Furthermore, by comparing MDCT and μCT results, an augmentation of the MDCT method is proposed, which allows for improved clot volume determination in a clinical setting. Y1 - 2020 U6 - https://doi.org/10.1097/MAT.0000000000001089 SN - 1538-943X VL - 66 IS - 8 SP - 922 EP - 928 PB - Lippincott Williams & Wilkins ER - TY - CHAP A1 - Cantalloube, Faustine A1 - Gomez-Gonzalez, Carlos A1 - Absil, Olivier A1 - Cantero, Carles A1 - Bacher, Regis A1 - Bonse, Markus A1 - Bottom, Michael A1 - Dahlqvist, Carl-Henrik A1 - Desgrange, Célia A1 - Flasseur, Olivier A1 - Fuhrmann, Thomas A1 - Henning, Thomas H. A1 - Jensen-Clem, Rebecca A1 - Kenworthy, Matthew A1 - Mawet, Dimitri A1 - Mesa, Dino A1 - Meshkat, Tiffany A1 - Mouillet, David A1 - Müller, André A1 - Nasedkin, Evert A1 - Pairet, Benoit A1 - Piérard, Sébastien A1 - Ruffio, Jean-Baptiste A1 - Samland, Matthias A1 - Stone, Jordan A1 - van Droogenbroeck, Marc ED - Schmidt, Dirk ED - Schreiber, Laura ED - Vernet, Elise T1 - Exoplanet imaging data challenge: benchmarking the various image processing methods for exoplanet detection T2 - Adaptive Optics Systems VII : 14-22 December 2020, online only, United States N2 - The Exoplanet Imaging Data Challenge is a community-wide effort meant to offer a platform for a fair and common comparison of image processing methods designed for exoplanet direct detection. For this purpose, it gathers on a dedicated repository (Zenodo), data from several high-contrast ground-based instruments worldwide in which we injected synthetic planetary signals. The data challenge is hosted on the CodaLab competition platform, where participants can upload their results. The specifications of the data challenge are published on our website https://exoplanet-imaging-challenge.github.io/. The first phase, launched on the 1st of September 2019 and closed on the 1st of October 2020, consisted in detecting point sources in two types of common data-set in the field of high-contrast imaging: data taken in pupil-tracking mode at one wavelength (subchallenge 1, also referred to as ADI) and multispectral data taken in pupil-tracking mode (subchallenge 2, also referred to as ADI+mSDI). In this paper, we describe the approach, organisational lessons-learnt and current limitations of the data challenge, as well as preliminary results of the participants’ submissions for this first phase. In the future, we plan to provide permanent access to the standard library of data sets and metrics, in order to guide the validation and support the publications of innovative image processing algorithms dedicated to high-contrast imaging of planetary systems. Y1 - 2020 SN - 9781510636835 U6 - https://doi.org/10.1117/12.2574803 PB - SPIE ER - TY - INPR A1 - Rück, Thomas A1 - Müller, Max A1 - Jobst, Simon A1 - Weigl, Stefan A1 - Pangerl, Jonas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Digital Twin of a Photoacoustic Trace Gas Sensor for Monitoring Methane in Complex Gas Compositions N2 - The digitalization of industrial processes requires smart sensor systems. Photoacoustic spectroscopy is well suited for this purpose as it allows for small-sized and low-cost trace gas analysis. However, the method is susceptible to changes in measurement conditions and standard calibration routines often fail to correct for all changes. We therefore created a Digital Twin (DT) of a photoacoustic trace gas sensor for methane and evaluated it regarding variations in gas composition (CH4, N2, O2, CO2, H2O), temperature and pressure. With a mean absolute percentage error of 0.8 % the accuracy of the sensor after DT compensation significantly exceeds the 24 % achieved based on standard calibration in nitrogen. For the first time, we can fully analytically compute the photoacoustic signal under moderate ambient conditions with an error in the ppbV range by taking a holistic approach. Assuming knowledge of the underlying energy transfer processes, the model of this Digital Twin can be adapted to any microphone based photoacoustic sensor for monitoring any analyte species. Y1 - 2022 U6 - https://doi.org/10.2139/ssrn.4215170 PB - Elsevier / SSRN ER - TY - CHAP A1 - Müller, Max A1 - Rück, Thomas A1 - Jobst, Simon A1 - Pangerl, Jonas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Creating a Digital Twin of a Photoacoustic Gas Sensor for Methane Detection in Complex Gas Matrices T2 - Proceedings Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES): 11–15 July 2022, Vancouver, British Columbia, Canada N2 - We present the calculation results from a digital twin (DT) of our photoacoustic (PA) sensor for methane detection, regarding gas composition, temperature and pressure variations. Y1 - 2022 SN - 978-1-957171-10-4 U6 - https://doi.org/10.1364/LACSEA.2022.LW4D.2 PB - Optica Publishing Group ER -