TY - CHAP A1 - Khaled, W. A1 - Bruhns, Otto T. A1 - Reichling, S. A1 - Böse, Holger A1 - Baumann, Michael A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Klein, Dagmar A1 - Freimuth, Herbert A1 - Ermert, Helmut T1 - A haptic sensor-actuator-system based on ultrasound elastography and electrorheological fluids for virtual reality applications in medicine T2 - CARS 2003 : computer assisted radiology and surgery ; proceedings of the 17th International Congress and Exhibition London, June 25 - 28, 2003 N2 - Mechanical properties of biological tissue represent important diagnostic information and are of histological relevance (hard lesions, "nodes" in organs: tumors; calcifications in vessels: arteriosclerosis). The problem is, that such information is usually obtained by digital palpation only, which is limited with respect to sensitivity. It requires intuitive assessment and does not allow quantitative documentation. A suitable sensor is required for quantitative detection of mechanical tissue properties. On the other hand, there is also some need for a realistic mechanical display of those tissue properties. Suitable actuator arrays with high spatial resolution and real-time capabilities are required operating in a haptic sensor actuator system with different applications. The sensor system uses real time ultrasonic elastography whereas the tactile actuator is based on electrorheological fluids. Due to their small size the actuator array elements have to be manufactured by micro-mechanical production methods. In order to supply the actuator elements with individual high voltages a sophisticated switching and control concept have been designed. This haptic system has the potential of inducing real time substantial forces, using a compact lightweight mechanism which can be applied to numerous areas including intraoperative navigation, telemedicine, teaching, space and telecommunication. Y1 - 2003 SP - 1354 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Khaled, W. A1 - Ermert, Helmut A1 - Bruhns, Otto T. A1 - Reichling, S. A1 - Böse, Holger A1 - Baumann, Michael A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Klein, Dagmar A1 - Freimuth, Herbert T1 - Haptic sensor-actuator-system based on ultrasound elastography and electrorheological fluids for virtual reality applications in medicine JF - Studies in health technology and informatics, Medicine Meets Virtual Reality (MMVR) N2 - Mechanical properties of biological tissue represent important diagnostic information and are of histological relevance (hard lesions, "nodes" in organs: tumors; calcifications in vessels: arteriosclerosis). The problem is, that such information is usually obtained by digital palpation only, which is limited with respect to sensitivity. It requires intuitive assessment and does not allow quantitative documentation. A suitable sensor is required for quantitative detection of mechanical tissue properties. On the other hand, there is also some need for a realistic mechanical display of those tissue properties. Suitable actuator arrays with high spatial resolution and real-time capabilities are required operating in a haptic sensor actuator system with different applications. The sensor system uses real time ultrasonic elastography whereas the tactile actuator is based on electrorheological fluids. Due to their small size the actuator array elements have to be manufactured by micro-mechanical production methods. In order to supply the actuator elements with individual high voltages a sophisticated switching and control concept have been designed. This haptic system has the potential of inducing real time substantial forces, using a compact lightweight mechanism which can be applied to numerous areas including intraoperative navigation, telemedicine, teaching, space and telecommunication. Y1 - 2003 VL - 11 IS - 94 SP - 144 EP - 150 PB - IOS Press ER - TY - CHAP A1 - Khaled, W. A1 - Bruhns, Otto T. A1 - Reichling, S. A1 - Böse, Holger A1 - Baumann, Michael A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Freimuth, Herbert A1 - Tunayar, A. A1 - Ermert, Helmut T1 - A New Haptic Sensor Actuator System for Virtual Reality Applications in Medicine T2 - Medical Image Computing and Computer-Assisted Intervention - MICCAI 2003: 6th International Conference, Montréal, Canada, November 15-18, 2003, Proceedings Y1 - 2003 SN - 978-3540204626 SP - 132 EP - 140 PB - Springer ER - TY - JOUR A1 - Khaled, W. A1 - Bruhns, Otto T. A1 - Reichling, S. A1 - Böse, Holger A1 - Baumann, Michael A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Klein, Dagmar A1 - Freimuth, Herbert A1 - Ermert, Helmut T1 - A haptic system for virtual reality applications based on ultrasound elastography and electrorheological fluids JF - Acoustical Imaging Y1 - 2004 U6 - https://doi.org/10.1007/978-1-4020-2402-3_85 IS - 27 SP - 667 EP - 675 PB - Kluver Academic CY - Dordrecht & New York ER - TY - JOUR A1 - Klein, Dagmar A1 - Freimuth, Herbert A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Böse, Holger A1 - Baumann, Michael A1 - Ermert, Helmut A1 - Bruhns, Otto T. T1 - Electrorheological Tactile Elements JF - Mechatronics N2 - The use of ultrasound systems for medical examination and diagnosis is nothing new. The extension of ultrasound techniques for real time elastographic analysis purposes represents a more recent development. Nevertheless, as they stand all such techniques rely on the interpretation of two-dimensional visual data displayed on a video screen. In reality however, a medical doctor will make as much use of exploratory touch as he or she does vision, making the simultaneous portrayal of both video and tactile information most desirable [Böse H, Monkman GJ, Freimuth H, Ermert H. Haptisches Sensor-Aktor-System uaf der grundlage der Echtzeitelastographie sowie von elktro- und magnetorheologischen Materialien “HASASEM” [3]. BMBF Antrag 01 IR A14D, Oktober 2000]. This paper discusses the preliminary tests and basic design parameters for single tactels using electrorheological fluids. The final aim is to produce a prototype three-dimensional tactile display comprising electrically switchable micro-machined cells whose mechanical moduli are governed by phase changes experienced by electrorheological fluids. This will be integrated with the latest elastographic ultrasonic sensor systems in order to present the human fingers with controllable surfaces capable of emulating biological tissue, muscle and bone. Y1 - 2005 U6 - https://doi.org/10.1016/j.mechatronics.2004.05.007 VL - 15 IS - 7 SP - 883 EP - 897 PB - Pergamon CY - Oxford ER - TY - CHAP A1 - Krämer, Stefan A1 - Mottok, Jürgen A1 - Meier, Hans T1 - Modifikation des Taskzustandsmodells des LLREF-Schedulers auf einem Dual-Core-Prozessor T2 - Proceedings of the 2nd Embedded Software Engineering Congress, 8. bis 10. Dezember 2009, Sindelfingen Y1 - 2009 SP - 628 EP - 636 ER - TY - CHAP A1 - Krämer, Stefan A1 - Mottok, Jürgen A1 - Meier, Hans T1 - Modifikation des Taskzustandsmodells des LLREF-Schedulers auf einem Dual-Core-Prozess T2 - Proceedings of the 2nd Embedded Software Engineering Congress, 8. bis 10. Dezember 2009, Sindelfingen Y1 - 2009 SP - 628 EP - 636 ER - TY - CHAP A1 - Krämer, Stefan A1 - Mottok, Jürgen A1 - Meier, Hans T1 - Osek-basierende Implementierung des LLREF-Scheduling-Algorithmus für eine Dual-Core-Architektur T2 - 2. Landshuter Symposium Mikrosystemtechnik, Tagungsband, 24. une 25. Februar 2010, Hochschule Landshut Y1 - 2010 SP - 343 EP - 349 ER - TY - JOUR A1 - Krämer, Stefan A1 - Mottok, Jürgen A1 - Meier, Hans T1 - Multi-Core Scheduling in Embedded Systemen, Teil 1 JF - Hanser Automotive Y1 - 2010 IS - 1-2 SP - 18 EP - 22 ER - TY - JOUR A1 - Krämer, Stefan A1 - Mottok, Jürgen A1 - Meier, Hans T1 - Multi-Core Scheduling in Embedded Systemen, Teil 2 JF - Hanser Automotive Y1 - 2010 IS - 3-4 SP - 23 EP - 25 ER - TY - JOUR A1 - Krämer, Stefan A1 - Mottok, Jürgen A1 - Meier, Hans T1 - Multi-Core Scheduling in Embedded Systemen, Teil 3 JF - Hanser Automotive Y1 - 2010 IS - 5-6 SP - 14 EP - 16 ER - TY - CHAP A1 - Raab, Peter A1 - Krämer, Stefan A1 - Mottok, Jürgen A1 - Meier, Hans A1 - Racek, Stanislav T1 - Safe software processing by concurrent execution in a real-time operating system T2 - 16th International Conference on Applied Electronics (AE 2011), 2011, Pilsen, Czech Republic N2 - The requirements for safety-related software systems increases rapidly. To detect arbitrary hardware faults, there are applicable coding mechanism, that add redundancy to the software. In this way it is possible to replace conventional multi-channel hardware and so reduce costs. Arithmetic codes are one possibility of coded processing and are used in this approach. A further approach to increase fault tolerance is the multiple execution of certain critical parts of software. This kind of time redundancy is easily realized by the parallel processing in an operating system. Faults in the program flow can be monitored. No special compilers, that insert additional generated code into the existing program, are required. The usage of multi-core processors would further increase the performance of such multi-channel software systems. In this paper we present the approach of program flow monitoring combined with coded processing, which is encapsulated in a library of coded data types. The program flow monitoring is indirectly realized by means of an operating system. Y1 - 2011 SP - 315 EP - 319 ER -