TY - JOUR A1 - Scharfenberg, Georg A1 - Mottok, Jürgen A1 - Artmann, Christina A1 - Hobelsberger, Martin A1 - Paric, Ivan A1 - Großmann, Benjamin A1 - Pohlt, Clemens A1 - Wackerbarth, Alena A1 - Pausch, Uli A1 - Heidrich, Christiane A1 - Fadanelli, Martin A1 - Elsner, Michael A1 - Pöcher, Daniel A1 - Pittroff, Lenz A1 - Beer, Stefan A1 - Brückl, Oliver A1 - Haslbeck, Matthias A1 - Sterner, Michael A1 - Thema, Martin A1 - Muggenthaler, Nicole A1 - Lenck, Thorsten A1 - Götz, Philipp A1 - Eckert, Fabian A1 - Deubzer, Michael A1 - Stingl, Armin A1 - Simsek, Erol A1 - Krämer, Stefan A1 - Großmann, Benjamin A1 - Schlegl, Thomas A1 - Niedersteiner, Sascha A1 - Berlehner, Thomas A1 - Joblin, Mitchell A1 - Mauerer, Wolfgang A1 - Apel, Sven A1 - Siegmund, Janet A1 - Riehle, Dirk A1 - Weber, Joachim A1 - Palm, Christoph A1 - Zobel, Martin A1 - Al-Falouji, Ghassan A1 - Prestel, Dietmar A1 - Scharfenberg, Georg A1 - Mandl, Roland A1 - Deinzer, Arnulf A1 - Halang, W. A1 - Margraf-Stiksrud, Jutta A1 - Sick, Bernhard A1 - Deinzer, Renate A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Störl, Uta A1 - Wiech, Katharina A1 - Kubata, Christoph A1 - Sindersberger, Dirk A1 - Monkman, Gareth J. A1 - Dollinger, Markus A1 - Dembianny, Sven A1 - Kölbl, Andreas A1 - Welker, Franz A1 - Meier, Matthias A1 - Thumann, Philipp A1 - Swidergal, Krzysztof A1 - Wagner, Marcus A1 - Haug, Sonja A1 - Vernim, Matthias A1 - Seidenstücker, Barbara A1 - Weber, Karsten A1 - Arsan, Christian A1 - Schone, Reinhold A1 - Münder, Johannes A1 - Schroll-Decker, Irmgard A1 - Dillinger, Andrea Elisabeth A1 - Fuchshofer, Rudolf A1 - Monkman, Gareth J. A1 - Shamonin (Chamonine), Mikhail A1 - Geith, Markus A. A1 - Koch, Fabian A1 - Ühlin, Christian A1 - Schratzenstaller, Thomas A1 - Saßmannshausen, Sean Patrick A1 - Auchter, Eberhard A1 - Kriz, Willy A1 - Springer, Othmar A1 - Thumann, Maria A1 - Kusterle, Wolfgang A1 - Obermeier, Andreas A1 - Udalzow, Anton A1 - Schmailzl, Anton A1 - Hierl, Stefan A1 - Langer, Christoph A1 - Schreiner, Rupert ED - Baier, Wolfgang T1 - Forschungsbericht 2015 T3 - Forschungsberichte der OTH Regensburg - 2015 Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13867 SN - 978-3-00-048589-3 CY - Regensburg ER - TY - CHAP A1 - Monkman, Gareth J. A1 - Böse, Holger A1 - Ermert, Helmut A1 - Klein, Dagmar A1 - Freimuth, Herbert A1 - Baumann, Míchael A1 - Egersdörfer, Stefan A1 - Bruhns, Otto T. A1 - Meier, Alexander A1 - Raja, Kashif ED - Nerlich, Michael ED - Schächinger, Ulrich T1 - Technologies for Haptic Systems in Telemedicine T2 - Integration of Health Telematics into Medical Practice N2 - The ability to image the elastic properties of tissue is potentially useful in a variety of applications. The field of elastic imaging has grown in response to the Potential use of such information in medical diagnosis. Real time ultrasound elastography represents a recent development in determining strain and elasticity distributions. Nevertheless, commonly used imaging techniques rely on the interpretation of two dimensional visual data displayed on a video screen. In reality however, physicians often prefer tactile exploration making the simultaneous portrayal of both video and haptic information most desirable. Since the 1970's many alphanumeric to tactile data conversion methods have been investigated, mainly with the ultimate aim of assisting the blind. More recently, interest has been directed toward the display of pictures on haptically explorable surfaces - Tactile imaging. Such a system would allow surgeons to examine hard sectors contained within soft tissue, and thereby assist in operations held remotely. The expansion of ultrasound elastography to 3D formats would mean the ability to haptically explore regions of the body normally inaccessible to human hands. For three-dimensional imaging the acquisition of sequential tomographic slices using Elastography, combined with image segmentation, enables the reconstruction, quantification and visualisation of tumour volumes. In a collaborative project between four research Institutes, the aim is to produce a prototype three dimensional tactile displays comprising electrically switchable micromachined cells, whose mechanical moduli are governed by phase changes experienced by electrorheological and/or magnetorheological fluids. This will be integrated with a sensory ultrasonic elastography in order to present the human fingers with controllable surfaces capable of emulating biological tissue, muscle and bone. Y1 - 2003 U6 - https://doi.org/10.3233/978-1-60750-941-7-83 SP - 83 EP - 93 PB - IOS Press ER - TY - JOUR A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Böse, Holger A1 - Baumann, Michael A1 - Ermert, Helmut A1 - Kahled, W. A1 - Freimuth, Herbert T1 - Technologies for Haptic Displays in Teleoperation JF - Industrial Robot N2 - Since the 1960s many alphanumeric to tactile data conversion methods have been investigated, mainly with the ultimate aim of assisting the blind. More recently, interest has been directed toward the display of pictures on haptically explorable surfaces – tactile imaging – for a range of medical, remote sensing and entertainment purposes. This paper examines the technologies which have been utilised for haptically explorable tactile displays over the past three decades, focussing on those which appear commercially viable in the immediate future. Y1 - 2003 U6 - https://doi.org/10.1108/01439910310506792 SN - 0143-991x VL - 30 IS - 6 SP - 525 EP - 530 PB - Emerald ER - TY - CHAP A1 - Khaled, W. A1 - Bruhns, Otto T. A1 - Reichling, S. A1 - Böse, Holger A1 - Baumann, Michael A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Klein, Dagmar A1 - Freimuth, Herbert A1 - Ermert, Helmut T1 - A haptic system for virtual reality applications based on ultrasound elastography and electrorheological fluids T2 - Acoustical Imaging (ACIM) N2 - Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. Malignant tumors are significantly stiffer and more immobile than surrounding healthy tissue. Hard calcifications in vessels occur due to arteriosclerosis. The problem is, that such information is usually not available or can only be obtained by manual palpation, which is subjective and limited in sensitivity. It requires intuitive assessment and does not allow quantitative documentation. Unfortunately, none of the established medical imaging equipment such as magnetic resonance imaging (MRI) or X-ray computed tomography (CT) can provide direct measure of tissue elasticity. On the one hand a suitable sensor is required for quantitative measurement of mechanical tissue properties. On the other hand there is also some need for a realistic haptic display of such tissue properties. Suitable actuator arrays with high spatial resolution acting in real time are required. A haptic sensor actuator system is presented in this paper including a sensitive sensor part and an actuator array for different applications. The mechanical consistency of an object is to be locally specified using a sensor system and represented perceptibly in a remote position on an actuator system for the user. The sensor system uses ultrasound (US) elastography, whereas the actuator array is based on electrorheological (ER) fluids. KW - Minimal Invasive Surgery KW - Manual Palpation KW - Tactile Display KW - Virtual Reality Application KW - Ultrasound ELASTOGRAPHY Y1 - 2004 SN - 978-90-481-6652-7 SN - 978-1-4020-2402-3 U6 - https://doi.org/10.1007/978-1-4020-2402-3_85 SN - 0270-5117 SN - 2215-1869 VL - 27 SP - 667 EP - 674 PB - Springer CY - Dordrecht ER - TY - CHAP A1 - Khaled, W. A1 - Bruhns, Otto T. A1 - Reichling, S. A1 - Böse, Holger A1 - Baumann, Michael A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Klein, Dagmar A1 - Freimuth, Herbert A1 - Ermert, Helmut T1 - A haptic sensor-actuator-system based on ultrasound elastography and electrorheological fluids for virtual reality applications in medicine T2 - CARS 2003 : computer assisted radiology and surgery ; proceedings of the 17th International Congress and Exhibition London, June 25 - 28, 2003 N2 - Mechanical properties of biological tissue represent important diagnostic information and are of histological relevance (hard lesions, "nodes" in organs: tumors; calcifications in vessels: arteriosclerosis). The problem is, that such information is usually obtained by digital palpation only, which is limited with respect to sensitivity. It requires intuitive assessment and does not allow quantitative documentation. A suitable sensor is required for quantitative detection of mechanical tissue properties. On the other hand, there is also some need for a realistic mechanical display of those tissue properties. Suitable actuator arrays with high spatial resolution and real-time capabilities are required operating in a haptic sensor actuator system with different applications. The sensor system uses real time ultrasonic elastography whereas the tactile actuator is based on electrorheological fluids. Due to their small size the actuator array elements have to be manufactured by micro-mechanical production methods. In order to supply the actuator elements with individual high voltages a sophisticated switching and control concept have been designed. This haptic system has the potential of inducing real time substantial forces, using a compact lightweight mechanism which can be applied to numerous areas including intraoperative navigation, telemedicine, teaching, space and telecommunication. Y1 - 2003 SP - 1354 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Khaled, W. A1 - Ermert, Helmut A1 - Bruhns, Otto T. A1 - Reichling, S. A1 - Böse, Holger A1 - Baumann, Michael A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Klein, Dagmar A1 - Freimuth, Herbert T1 - Haptic sensor-actuator-system based on ultrasound elastography and electrorheological fluids for virtual reality applications in medicine JF - Studies in health technology and informatics, Medicine Meets Virtual Reality (MMVR) N2 - Mechanical properties of biological tissue represent important diagnostic information and are of histological relevance (hard lesions, "nodes" in organs: tumors; calcifications in vessels: arteriosclerosis). The problem is, that such information is usually obtained by digital palpation only, which is limited with respect to sensitivity. It requires intuitive assessment and does not allow quantitative documentation. A suitable sensor is required for quantitative detection of mechanical tissue properties. On the other hand, there is also some need for a realistic mechanical display of those tissue properties. Suitable actuator arrays with high spatial resolution and real-time capabilities are required operating in a haptic sensor actuator system with different applications. The sensor system uses real time ultrasonic elastography whereas the tactile actuator is based on electrorheological fluids. Due to their small size the actuator array elements have to be manufactured by micro-mechanical production methods. In order to supply the actuator elements with individual high voltages a sophisticated switching and control concept have been designed. This haptic system has the potential of inducing real time substantial forces, using a compact lightweight mechanism which can be applied to numerous areas including intraoperative navigation, telemedicine, teaching, space and telecommunication. Y1 - 2003 VL - 11 IS - 94 SP - 144 EP - 150 PB - IOS Press ER - TY - CHAP A1 - Khaled, W. A1 - Bruhns, Otto T. A1 - Reichling, S. A1 - Böse, Holger A1 - Baumann, Michael A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Freimuth, Herbert A1 - Tunayar, A. A1 - Ermert, Helmut T1 - A New Haptic Sensor Actuator System for Virtual Reality Applications in Medicine T2 - Medical Image Computing and Computer-Assisted Intervention - MICCAI 2003: 6th International Conference, Montréal, Canada, November 15-18, 2003, Proceedings Y1 - 2003 SN - 978-3540204626 SP - 132 EP - 140 PB - Springer ER - TY - JOUR A1 - Khaled, W. A1 - Bruhns, Otto T. A1 - Reichling, S. A1 - Böse, Holger A1 - Baumann, Michael A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Klein, Dagmar A1 - Freimuth, Herbert A1 - Ermert, Helmut T1 - A haptic system for virtual reality applications based on ultrasound elastography and electrorheological fluids JF - Acoustical Imaging Y1 - 2004 U6 - https://doi.org/10.1007/978-1-4020-2402-3_85 IS - 27 SP - 667 EP - 675 PB - Kluver Academic CY - Dordrecht & New York ER - TY - JOUR A1 - Klein, Dagmar A1 - Freimuth, Herbert A1 - Monkman, Gareth J. A1 - Egersdörfer, Stefan A1 - Meier, Alexander A1 - Böse, Holger A1 - Baumann, Michael A1 - Ermert, Helmut A1 - Bruhns, Otto T. T1 - Electrorheological Tactile Elements JF - Mechatronics N2 - The use of ultrasound systems for medical examination and diagnosis is nothing new. The extension of ultrasound techniques for real time elastographic analysis purposes represents a more recent development. Nevertheless, as they stand all such techniques rely on the interpretation of two-dimensional visual data displayed on a video screen. In reality however, a medical doctor will make as much use of exploratory touch as he or she does vision, making the simultaneous portrayal of both video and tactile information most desirable [Böse H, Monkman GJ, Freimuth H, Ermert H. Haptisches Sensor-Aktor-System uaf der grundlage der Echtzeitelastographie sowie von elktro- und magnetorheologischen Materialien “HASASEM” [3]. BMBF Antrag 01 IR A14D, Oktober 2000]. This paper discusses the preliminary tests and basic design parameters for single tactels using electrorheological fluids. The final aim is to produce a prototype three-dimensional tactile display comprising electrically switchable micro-machined cells whose mechanical moduli are governed by phase changes experienced by electrorheological fluids. This will be integrated with the latest elastographic ultrasonic sensor systems in order to present the human fingers with controllable surfaces capable of emulating biological tissue, muscle and bone. Y1 - 2005 U6 - https://doi.org/10.1016/j.mechatronics.2004.05.007 VL - 15 IS - 7 SP - 883 EP - 897 PB - Pergamon CY - Oxford ER - TY - CHAP A1 - Krämer, Stefan A1 - Mottok, Jürgen A1 - Meier, Hans T1 - Modifikation des Taskzustandsmodells des LLREF-Schedulers auf einem Dual-Core-Prozessor T2 - Proceedings of the 2nd Embedded Software Engineering Congress, 8. bis 10. Dezember 2009, Sindelfingen Y1 - 2009 SP - 628 EP - 636 ER - TY - CHAP A1 - Krämer, Stefan A1 - Mottok, Jürgen A1 - Meier, Hans T1 - Modifikation des Taskzustandsmodells des LLREF-Schedulers auf einem Dual-Core-Prozess T2 - Proceedings of the 2nd Embedded Software Engineering Congress, 8. bis 10. Dezember 2009, Sindelfingen Y1 - 2009 SP - 628 EP - 636 ER -