TY - GEN A1 - Tauwald, Sandra Melina A1 - Quadrio, Maurizio A1 - Rütten, Markus A1 - Stemmer, Christian A1 - Krenkel, Lars T1 - High Spatial Resolution Tomo-PIV of the Nasopharynx Focussing on the Physiological Breathing Cycle T2 - 23. DGLR Fach-Symposium Strömungen mit Ablösung, 09./10. November 2022, Berlin, Deutschland N2 - Investigations of complex patient-specific flow in the nasopharynx requires high resolution numerical calculations validated by reliable experiments. When building the validation base and the benchmark of computational fluid dynamics, an experimental setup of the nasal airways was developed. The applied optical measurement technique of tomo-PIV supplies information on the governing flow field in three dimensions. This paper presents tomo-PIV measurements of the highly complex patient-specific geometry of the human trachea. A computertomographic scan of a person’s head builds the basis of the experimental silicone model of the nasal airways. An optimised approach for precise refractive index matching avoids optical distortions even in highly complex non-free-of-sight 3D geometries. A linear-motor-driven pump generates breathing scenarios, based on measured breathing cycles. Adjusting of the CCD cameras‘ double-frame-rate PIV-Δt enables the detailed analysis of flow structures during different cycle phases. Merging regions of interest enables high spatial resolution acquisition of the flow field. KW - Tomographic PIV KW - Flow visualisation KW - Physiological Breathing KW - Nasal airflow Y1 - 2022 UR - https://www.dlr.de/as/Portaldata/5/Resources/dokumente/veranstaltungen/stab_workshop/Jahresbericht2022.pdf CY - Göttingen ER - TY - CHAP A1 - Tauwald, Sandra Melina A1 - Quadrio, Maurizio A1 - Rütten, Markus A1 - Stemmer, Christian A1 - Krenkel, Lars T1 - High Spatial Resolution Tomo-PIV of the Trachea Focussing on the Physiological Breathing Cycle T2 - New Results in Numerical and Experimental Fluid Mechanics XIV - Contributions to the 23nd STAB/DGLR Symposium N2 - Investigations of complex patient-specific flow in the nasopharynx requires high resolution numerical calculations validated by reliable experiments. When building the validation base and the benchmark of computational fluid dynamics, an experimental setup of the nasal airways was developed. The applied optical measurement technique of tomo-PIV supplies information on the governing flow field in three dimensions. This paper presents tomo-PIV measurements of the highly complex patient-specific geometry of the human trachea. A computertomographic scan of a person’s head builds the basis of the experimental silicone model of the nasal airways. An optimised approach for precise refractive index matching avoids optical distortions even in highly complex non-free-of-sight 3D geometries. A linear-motor-driven pump generates breathing scenarios, based on measured breathing cycles. Adjusting of the CCD cameras‘ double-frame-rate PIV-Δt enables the detailed analysis of flow structures during different cycle phases. Merging regions of interest enables high spatial resolution acquisition of the flow field. KW - Tomographic PIV KW - Flow visualisation KW - Breathing cycle KW - Nasal airflow Y1 - 2023 N1 - Accepted for publication, not yet published PB - Springer ER - TY - JOUR A1 - Tauwald, Sandra Melina A1 - Erzinger, Florian A1 - Quadrio, Maurizio A1 - Rütten, Markus A1 - Stemmer, Christian A1 - Krenkel, Lars T1 - Tomo-PIV in a patient-specific model of human nasal cavities: a methodological approach JF - Measurement Science and Technology N2 - The human nose serves as the primary gateway for air entering the respiratory system and plays a vital role in breathing. Nasal breathing difficulties are a significant health concern, leading to substantial healthcare costs for patients. Understanding nasal airflow dynamics is crucial for comprehending respiratory mechanisms. This article presents a detailed study using tomo-Particle Image Velocimetry (PIV) to investigate nasal airflow dynamics while addressing its accuracy. Embedded in the OpenNose project, the work described aims to provide a validation basis for different numerical approaches to upper airway flow. The study includes the manufacturing of a transparent silicone model based on a clinical CT scan, refractive index matching to minimize optical distortions, and precise flow rate adjustments based on physiological breathing cycles. This method allows for spatial high-resolution investigations in different regions of interest within the nasopharynx during various phases of the breathing cycle. The results demonstrate the accuracy of the investigations, enabling detailed analysis of flow structures and gradients. This spatial high-resolution tomo-PIV approach provides valuable insights into the complex flow phenomena occurring during the physiological breathing cycle in the nasopharynx. The study's findings contribute to advancements in non-free-of-sight experimental flow investigation of complex cavities under nearly realistic conditions. Furthermore, reliable and accurate experimental data is crucial for properly validating numerical approaches that compute this patient-specific flow for clinical purposes. Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-70393 N1 - Corresponding author: Sandra Melina Tauwald VL - 35 IS - 5 PB - IOP Publishing ER - TY - CHAP A1 - Rütten, Markus A1 - Krenkel, Lars A1 - Quadrio, Maurizio T1 - Simulation and Analyis of the Unsteady Flow within Nasal Airways T2 - 9th European Congress on Computational Methods in Applied Sciences and Engineering - ECCOMAS Congress, 3-7 June 2024, Lisbon, Portugal Y1 - 2024 UR - https://re.public.polimi.it/handle/11311/1269952 ER -