TY - CHAP A1 - Paric, Ivan A1 - Greim, Markus A1 - Erhardt, Markus A1 - Weißmann, Horst A1 - Kusterle, Wolfgang ED - Kusterle, Wolfgang ED - Teubert, Oliver ED - Greim, Markus T1 - Untersuchung, Beurteilung und zeitnahe Aussteuerung der rheologischen Frischbetoneigenschaften von SVB T2 - Rheologische Messungen an Baustoffen 2018. Tagungsband zum 27. Workshop und Kolloquium, 7. und 8. März an der OTH Regensburg KW - Beton KW - Rheologische Eigenschaft Y1 - 2018 SN - 978-3-7469-1878-5 IS - 1. Auflage SP - 154 EP - 168 PB - tredition CY - Hamburg ER - TY - JOUR A1 - Keller, Helena A1 - Greim, Markus A1 - Kusterle, Wolfgang T1 - 27th Conference and Workshop on Rheology of Building Materials, Ostbayerische Technische Hochschule (OTH) Regensburg, Germany, March 7 – 8, 2018 BT - Conference report JF - Applied Rheology Y1 - 2018 U6 - https://doi.org/10.1515/arh-2018-0005 VL - 28 IS - 2 SP - 56 EP - 58 PB - De Gruyter ER - TY - JOUR A1 - Greim, Markus A1 - Kusterle, Wolfgang T1 - 23rd Conference and Workshop Rheology of Building Materials. Ostbayerische Technische Hochschule Regensburg, Germany March 12–13, 2014 JF - Applied Rheology Y1 - 2014 U6 - https://doi.org/10.3933/ApplRheol-24-3-61 VL - 24 IS - 3 SP - 61 EP - 62 PB - Kerschensteiner ER - TY - CHAP A1 - Paric, Ivan A1 - Fleischmann, Florian A1 - Greim, Markus A1 - Kusterle, Wolfgang T1 - The Determination of Rheological Properties of "High Slump Concrete" and SCC - the Advantages of a Modified Online Ball Measuring System T2 - Rheologische Messungen an Baustoffen 2016, Tagungsband zum 25. Workshop und Kolloquium, 2. und 3. März an der OTH Regensburg N2 - In this paper a new rheometer for Self-Compacting-Concrete (SCC) and High-Slump-Concrete is presented. It is installed in a concrete mixer and provides results of the rheological properties immediately at the end of the mixing process. The intention was to find a way to evaluate the rheological properties automatically in the last step of the mixing process. Therefore, the rheometer immerses in the concrete and starts the measurement. At this time a correction of the mixture is still possible, before it is filled into the truck. In a first step, a laboratory rheometer was built and the measurement procedure was developed. In a second step, the laboratory rheometer was installed in a 75 1 concrete mixer and data were collected and evaluated. The accuracy is proven by comparing test results with a slightly different mix design. KW - Betonmischer KW - Messgerät KW - Messmaschine KW - Messsystem KW - Messverfahren KW - rheologische Eigenschaft KW - Rheometer KW - selbstverdichtender Beton KW - Vergleichsanalyse KW - Vergleichsprüfung Y1 - 2016 UR - http://www.schleibinger.com/cmsimple/en/?Rheology_Of_Building_Materials:25th_Conference SN - 978-3-7345-1313-8 SP - 247 EP - 264 PB - tredition CY - Hamburg ER -