TY - CHAP A1 - Cantalloube, Faustine A1 - Gomez-Gonzalez, Carlos A1 - Absil, Olivier A1 - Cantero, Carles A1 - Bacher, Regis A1 - Bonse, Markus A1 - Bottom, Michael A1 - Dahlqvist, Carl-Henrik A1 - Desgrange, Célia A1 - Flasseur, Olivier A1 - Fuhrmann, Thomas A1 - Henning, Thomas H. A1 - Jensen-Clem, Rebecca A1 - Kenworthy, Matthew A1 - Mawet, Dimitri A1 - Mesa, Dino A1 - Meshkat, Tiffany A1 - Mouillet, David A1 - Müller, André A1 - Nasedkin, Evert A1 - Pairet, Benoit A1 - Piérard, Sébastien A1 - Ruffio, Jean-Baptiste A1 - Samland, Matthias A1 - Stone, Jordan A1 - van Droogenbroeck, Marc ED - Schmidt, Dirk ED - Schreiber, Laura ED - Vernet, Elise T1 - Exoplanet imaging data challenge: benchmarking the various image processing methods for exoplanet detection T2 - Adaptive Optics Systems VII : 14-22 December 2020, online only, United States N2 - The Exoplanet Imaging Data Challenge is a community-wide effort meant to offer a platform for a fair and common comparison of image processing methods designed for exoplanet direct detection. For this purpose, it gathers on a dedicated repository (Zenodo), data from several high-contrast ground-based instruments worldwide in which we injected synthetic planetary signals. The data challenge is hosted on the CodaLab competition platform, where participants can upload their results. The specifications of the data challenge are published on our website https://exoplanet-imaging-challenge.github.io/. The first phase, launched on the 1st of September 2019 and closed on the 1st of October 2020, consisted in detecting point sources in two types of common data-set in the field of high-contrast imaging: data taken in pupil-tracking mode at one wavelength (subchallenge 1, also referred to as ADI) and multispectral data taken in pupil-tracking mode (subchallenge 2, also referred to as ADI+mSDI). In this paper, we describe the approach, organisational lessons-learnt and current limitations of the data challenge, as well as preliminary results of the participants’ submissions for this first phase. In the future, we plan to provide permanent access to the standard library of data sets and metrics, in order to guide the validation and support the publications of innovative image processing algorithms dedicated to high-contrast imaging of planetary systems. Y1 - 2020 SN - 9781510636835 U6 - https://doi.org/10.1117/12.2574803 PB - SPIE ER - TY - JOUR A1 - Pangerl, Jonas A1 - Müller, Max A1 - Rück, Thomas A1 - Weigl, Stefan A1 - Bierl, Rudolf T1 - Characterizing a sensitive compact mid-infrared photoacoustic sensor for methane, ethane and acetylene detection considering changing ambient parameters and bulk composition (N2, O2 and H2O) JF - Sensors and Actuators B: Chemical N2 - We present a sensitive and compact interband cascade laser (ICL) based photoacoustic setup for the detection of gaseous hydrocarbons and discuss its applicability towards trace gas analysis. We investigated the performance of the sensor for trace concentrations of methane, ethane and acetylene diluted in nitrogen. The excitation of methane and ethane was accomplished using one tunable diode laser, covering a range from 3360 to 3372 nm, which was replaced by a separate ICL at 3025 nm for acetylene detection. The influence of ambient parameters such as temperature, flow rate and pressure as well as potential cross-sensitivities towards O2 and H2O have been examined in terms of methane and acetylene detection. A series of simulations proved several of these influences to be attributed to relaxation effects. With a 3σ limit of detection (LoD) of 6.8 parts per billion (ppbV) in case of methane, 2.3 ppbV regarding ethane and 3.6 ppbV in terms of acetylene, the sensor demonstrates a great potential for applications in the field of trace gas analysis. KW - Acetylene KW - Cross-sensitivities KW - Ethane KW - Interband cascade laser KW - Methane KW - Photoacoustic spectroscopy KW - Relaxation effects Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-25868 N1 - Corresponding author: Jonas Pangerl VL - 352,1 SP - 1 EP - 12 PB - Elsevier ER - TY - JOUR A1 - Müller, Max A1 - Rück, Thomas A1 - Jobst, Simon A1 - Pangerl, Jonas A1 - Weigl, Stefan A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - An Algorithmic Approach to Compute the Effect of Non-Radiative Relaxation Processes in Photoacoustic Spectroscopy JF - Photoacoustics N2 - Successful transfer of photoacoustic gas sensors from laboratory to real-life applications requires knowledge about potential cross-sensitivities towards environmental and gas matrix changes. Multi-dimensional calibration in case of cross-sensitivities can become very complex or even unfeasible. To address this challenge, we present a novel algorithm to compute the collision based non-radiative efficiency and phase lag of energy relaxation on a molecular level (CoNRad) for photoacoustic signal calculation. This algorithmic approach allows to calculate the entire elaxation cascade of arbitrarily complex systems, yielding a theoretical photoacoustic signal. In this work the influence of varying bulk compositions, i.e. nitrogen (N2), oxygen (O2) and water (H2O) on the photoacoustic signal during methane (CH4) detection is demonstrated. The applicability of the algorithm to other photoacoustic setups is shown exemplary by applying it to the relaxational system investigated in [1]. Hayden et al. examined the effect of water on photoacoustic carbon monoxide (CO) detection. Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-39935 N1 - Corresponding author: Max Müller VL - 26 PB - Elsevier ER - TY - RPRT A1 - Steiger, Tamara A1 - Foltan, Maik A1 - Philipp, Alois A1 - Müller, Thomas A1 - Gruber, Michael A1 - Bredthauer, Andre A1 - Krenkel, Lars A1 - Birkenmaier, Clemens A1 - Lehle, Karla T1 - Accumulations of von Willebrand factor within ECMO oxygenators: Potential indicator of coagulation abnormalities in critically ill patients? N2 - Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots—in particular, the presence of von Willebrand factor (vWF)—may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti‐vWF and anti‐P‐selectin) and counterstained with 4′,6‐diamidino‐2‐phenylindole. The extent of vWF‐loading was correlated with patient and technical data. While 12 MOs showed low vWF‐loadings, 9 MOs showed high vWF‐loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF‐fibers/“cobwebs,” leukocytes, platelet–leukocyte aggregates (PLAs), and P‐selectin‐positive platelet aggregates were independent of the extent of vWF‐loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high‐molecular‐weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy. Y1 - 2019 ER - TY - JOUR A1 - Birkenmaier, Clemens A1 - Dornia, Christian A1 - Lehle, Karla A1 - Müller, Thomas A1 - Gruber, Michael A1 - Philipp, Alois A1 - Krenkel, Lars T1 - Analysis of Thrombotic Deposits in Extracorporeal Membrane Oxygenators by High-resolution Microcomputed Tomography: A Feasibility Study JF - ASAIO Journal / American Society for Artificial Internal Organs N2 - Coagulative disorders, especially clotting during extracorporeal membrane oxygenation, are frequent complications. Direct visualization and analysis of deposits in membrane oxygenators using computed tomography (CT) may provide an insight into the underlying mechanisms causing thrombotic events. However, the already established multidetector CT1 (MDCT) method shows major limitations. Here, we demonstrate the feasibility of applying industrial micro-CT (μCT) to circumvent these restrictions. Three clinically used membrane oxygenators were investigated applying both MDCT and μCT. The scans were analyzed in terms of clot volume and local clot distribution. As validation, the clot volume was also determined from the fluid volume, which could be filled into the respective used oxygenator compared to a new device. In addition, cross-sectional CT images were compared with crosscut oxygenators. Based on the μCT findings, a morphological measure (sphericity) for assessing clot structures in membrane oxygenators is introduced. Furthermore, by comparing MDCT and μCT results, an augmentation of the MDCT method is proposed, which allows for improved clot volume determination in a clinical setting. Y1 - 2020 U6 - https://doi.org/10.1097/MAT.0000000000001089 SN - 1538-943X VL - 66 IS - 8 SP - 922 EP - 928 PB - Lippincott Williams & Wilkins ER - TY - CHAP A1 - Müller, Andreas A1 - Falter, Thomas ED - Wörwag, Sebastian ED - Cloots, Alexandra T1 - Sechs Führungsperspektiven für die digitale Transformation – Welche Dashboards das Veränderungsmanagement in digitalen Zeiten unterstützen können BT - Ein Praxisbericht T2 - Arbeitskulturen im Wandel N2 - Während KPIs und Dashboards in großer Zahl für den Betrieb eines Unternehmens im eingeschwungenen Zustand zur Verfügung stehen, scheint es insbesondere in der digitalen Transformation besonders schwierig zu sein, Orientierung zu behalten und zu vermitteln. Welche Aspekte sind dabei wichtig? Was ist der Einfluss der Unternehmenskultur? In welcher Reihenfolge sollen wir vorgehen? Wie können wir die wichtigen Parameter messen und visualisieren? Auf diese Fragen geben wir unter Berücksichtigung unterschiedlicher Modelle und Perspektiven Antworten und zeigen am hypothetischen Beispiel eines Autohauses mögliche konkrete Aktionen exemplarisch auf. Y1 - 2020 SN - 978-3-658-30450-8 U6 - https://doi.org/10.1007/978-3-658-30451-5_12 SP - 239 EP - 257 PB - Springer Gabler CY - Wiesbaden ER - TY - RPRT A1 - Burlon, Thomas A1 - Emde, Markus A1 - Hönig, Tobias A1 - Müller, Cornelia A1 - Neznanow, Arthur A1 - Rampl, Markus A1 - Sammut, Alexine A1 - Schlüßler, Kristof A1 - Sievert Asmussen, Eva T1 - 0169 Karl-Hammerschmidt-Straße, Architekturkultur Y1 - 2020 UR - https://www.studioemde.com/0169-karl-hammerschmidt-strasse-munich-2014 ER - TY - INPR A1 - Rück, Thomas A1 - Müller, Max A1 - Jobst, Simon A1 - Weigl, Stefan A1 - Pangerl, Jonas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Digital Twin of a Photoacoustic Trace Gas Sensor for Monitoring Methane in Complex Gas Compositions N2 - The digitalization of industrial processes requires smart sensor systems. Photoacoustic spectroscopy is well suited for this purpose as it allows for small-sized and low-cost trace gas analysis. However, the method is susceptible to changes in measurement conditions and standard calibration routines often fail to correct for all changes. We therefore created a Digital Twin (DT) of a photoacoustic trace gas sensor for methane and evaluated it regarding variations in gas composition (CH4, N2, O2, CO2, H2O), temperature and pressure. With a mean absolute percentage error of 0.8 % the accuracy of the sensor after DT compensation significantly exceeds the 24 % achieved based on standard calibration in nitrogen. For the first time, we can fully analytically compute the photoacoustic signal under moderate ambient conditions with an error in the ppbV range by taking a holistic approach. Assuming knowledge of the underlying energy transfer processes, the model of this Digital Twin can be adapted to any microphone based photoacoustic sensor for monitoring any analyte species. Y1 - 2022 U6 - https://doi.org/10.2139/ssrn.4215170 PB - Elsevier / SSRN ER - TY - CHAP A1 - Müller, Max A1 - Rück, Thomas A1 - Jobst, Simon A1 - Pangerl, Jonas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Creating a Digital Twin of a Photoacoustic Gas Sensor for Methane Detection in Complex Gas Matrices T2 - Proceedings Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES): 11–15 July 2022, Vancouver, British Columbia, Canada N2 - We present the calculation results from a digital twin (DT) of our photoacoustic (PA) sensor for methane detection, regarding gas composition, temperature and pressure variations. Y1 - 2022 SN - 978-1-957171-10-4 U6 - https://doi.org/10.1364/LACSEA.2022.LW4D.2 PB - Optica Publishing Group ER - TY - JOUR A1 - Schroll-Decker, Irmgard A1 - Müller, Thomas A1 - Wesemann, Anna T1 - Wohlbefinden von Kindern und Jugendlichen im Heim JF - Unsere Jugend KW - Soziale Arbeit KW - Sozialpädagogik Y1 - 2009 SN - 0342-5258 VL - 61 IS - 11+12 SP - 490 EP - 504 PB - Reinhardt ER -