TY - JOUR A1 - Maier, Johannes A1 - Knott, Bernadette A1 - März, Manuel A1 - Löschel, Rainer A1 - Kölbl, Oliver A1 - Dobler, Barbara T1 - Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study JF - Radiation oncology N2 - Background: The aim of the study was to compare the two irradiation modes with (FF) and without flattening filter (FFF) for three different treatment techniques for simultaneous integrated boost radiation therapy of patients with right sided breast cancer. Methods: An Elekta Synergy linac with Agility collimating device is used to simulate the treatment of 10 patients. Six plans were generated in Monaco 5.0 for each patient treating the whole breast and a simultaneous integrated boost (SIB) volume: intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and a tangential arc VMAT (tVMAT), each with and without flattening filter. Plan quality was assessed considering target coverage, sparing of the contralateral breast, the lungs, the heart and the normal tissue. All plans were verified by a 2D-ionisation-chamber-array and delivery times were measured and compared. The Wilcoxon test was used for statistical analysis with a significance level of 0.05. Results: Significantly best target coverage and homogeneity was achieved using VMAT FFF with V95% = (98.7 +/- 0.8) % and HI = (8.2 +/- 0.9) % for the SIB and V95% = (98.3 +/- 0.7) % for the PTV, whereas tVMAT showed significantly lowest doses to the contralateral organs at risk with a D-mean of (0.7 +/- 0.1) Gy for the contralateral lung, (1.0 +/- 0.2) Gy for the contralateral breast and (1.4 +/- 0.2) Gy for the heart. All plans passed the gamma evaluation with a mean passing rate of (99.2 +/- 0.8) %. Delivery times were significantly reduced for VMAT and tVMAT but increased for IMRT, when FFF was used. Lowest delivery times were observed for tVMAT FFF with (1:20 +/- 0:07) min. Conclusion: Balancing target coverage, OAR sparing and delivery time, VMAT FFF and tVMAT FFF are considered the preferable of the investigated treatment options in simultaneous integrated boost irradiation of right sided breast cancer for the combination of an Elekta Synergy linac with Agility and the treatment planning system Monaco 5.0. KW - 3D-CRT KW - CONSERVING THERAPY KW - FIELD KW - IMRT KW - Radiotherapy KW - VMAT Y1 - 2016 U6 - https://doi.org/10.1186/s13014-016-0687-6 VL - 11 PB - BMC, Part of Springer Nature ER - TY - JOUR A1 - Dobler, Barbara A1 - Maier, Johannes A1 - Knott, Bernadette A1 - Maerz, Manuel A1 - Löschel, Rainer A1 - Kölbl, Oliver T1 - Second Cancer Risk after simultaneous integrated boost radiation therapy of right sided breast cancer with and without flattening filter JF - Strahlentherapie und Onkologie N2 - Background The aim of this study was to investigate if the flattening filter free mode (FFF) of a linear accelerator reduces the excess absolute risk (EAR) for second cancer as compared to the flat beam mode (FF) in simultaneous integrated boost (SIB) radiation therapy of right-sided breast cancer. Patients and methods Six plans were generated treating the whole breast to 50.4 Gy and a SIB volume to 63 Gy on CT data of 10 patients: intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT), and a tangential arc VMAT (tVMAT), each with flattening filter and without. The EAR was calculated for the contralateral breast and the lungs from dose-volume histograms (DVH) based on the linear-exponential, the plateau, and the full mechanistic dose-response model. Peripheral low-dose measurements were performed to compare the EAR in more distant regions as the thyroids and the uterus. Results FFF reduces the EAR significantly in the contralateral and peripheral organs for tVMAT and in the peripheral organs for VMAT. No reduction was found for IMRT. The lowest EAR for the contralateral breast and lung was achieved with tVMAT FFF, reducing the EAR by 25 % and 29 % as compared to tVMAT FF, and by 44 % to 58 % as compared to VMAT and IMRT in both irradiation modes. tVMAT FFF showed also the lowest peripheral dose corresponding to the lowest EAR in the thyroids and the uterus. Conclusion The use of FFF mode allows reducing the EAR significantly when tVMAT is used as the treatment technique. When second cancer risk is a major concern, tVMAT FFF is considered the preferred treatment option in SIB irradiation of right-sided breast cancer. T2 - Sekundärmalignom-Risiko nach simultan integrierter Boost-Bestrahlung des rechtsseitigen Mamma-Karzinoms mit und ohne Ausgleichskörper KW - 3D-CRT KW - Breast Cancer KW - CONTRALATERAL BREAST KW - DOSES RELEVANT KW - flattening filter free KW - HODGKIN COHORTS KW - IMRT KW - INDUCTION KW - JAPANESE A-BOMB KW - Peripheral Dose KW - PREDICTED RISK KW - Radiotherapy KW - Second Cancer Risk KW - VMAT Y1 - 2016 U6 - https://doi.org/10.1007/s00066-016-1025-5 VL - 192 IS - 10 SP - 687 EP - 695 PB - Springer Nature CY - Heidelberg ER - TY - JOUR A1 - Huber, Michaela A1 - Schlosser, Daniela A1 - Stenzel, Susanne A1 - Maier, Johannes A1 - Pattappa, Girish A1 - Kujat, Richard A1 - Striegl, Birgit A1 - Docheva, Denitsa T1 - Quantitative Analysis of Surface Contouring with Pulsed Bipolar Radiofrequency on Thin Chondromalacic Cartilage JF - BioMed Research International N2 - The purpose of this study was to evaluate the quality of surface contouring of chondromalacic cartilage by bipolar radio frequency energy using different treatment patterns in an animal model, as well as examining the impact of the treatment onto chondrocyte viability by two different methods. Our experiments were conducted on 36 fresh osteochondral sections from the tibia plateau of slaughtered 6-month-old pigs, where the thickness of the cartilage is similar to that of human wrist cartilage. An area of 1 cm(2) was first treated with emery paper to simulate the chondromalacic cartilage. Then, the treatment with RFE followed in 6 different patterns. The osteochondral sections were assessed for cellular viability (live/dead assay, caspase (cell apoptosis marker) staining, and quantitative analysed images obtained by fluorescent microscopy). For a quantitative characterization of none or treated cartilage surfaces, various roughness parameters were measured using confocal laser scanning microscopy (Olympus LEXT OLS 4000 3D). To describe the roughness, the Root-Mean-Square parameter (Sq) was calculated. A smoothing effect of the cartilage surface was detectable upon each pattern of RFE treatment. The Sq for native cartilage was Sq=3.8 +/- 1.1 mu m. The best smoothing pattern was seen for two RFE passes and a 2-second pulsed mode (B2p2) with an Sq=27.3 +/- 4.9 mu m. However, with increased smoothing, an augmentation in chondrocyte death up to 95% was detected. Using bipolar RFE treatment in arthroscopy for small joints like the wrist or MCP joints should be used with caution. In the case of chondroplasty, there is a high chance to destroy the joint cartilage. KW - CHONDROCYTE DEATH KW - energy KW - HUMAN ARTICULAR-CARTILAGE KW - MONOPOLAR KW - THERMAL CHONDROPLASTY Y1 - 2020 U6 - https://doi.org/10.1155/2020/1242086 SP - 1 EP - 8 PB - HINDAWI ER - TY - JOUR A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph T1 - Optically tracked and 3D printed haptic phantom hand for surgical training system JF - Quantitative Imaging in Medicine and Surgery N2 - Background: For surgical fixation of bone fractures of the human hand, so-called Kirschner-wires (K-wires) are drilled through bone fragments. Due to the minimally invasive drilling procedures without a view of risk structures like vessels and nerves, a thorough training of young surgeons is necessary. For the development of a virtual reality (VR) based training system, a three-dimensional (3D) printed phantom hand is required. To ensure an intuitive operation, this phantom hand has to be realistic in both, its position relative to the driller as well as in its haptic features. The softest 3D printing material available on the market, however, is too hard to imitate human soft tissue. Therefore, a support-material (SUP) filled metamaterial is used to soften the raw material. Realistic haptic features are important to palpate protrusions of the bone to determine the drilling starting point and angle. An optical real-time tracking is used to transfer position and rotation to the training system. Methods: A metamaterial already developed in previous work is further improved by use of a new unit cell. Thus, the amount of SUP within the volume can be increased and the tissue is softened further. In addition, the human anatomy is transferred to the entire hand model. A subcutaneous fat layer and penetration of air through pores into the volume simulate shiftability of skin layers. For optical tracking, a rotationally symmetrical marker attached to the phantom hand with corresponding reference marker is developed. In order to ensure trouble-free position transmission, various types of marker point applications are tested. Results: Several cuboid and forearm sample prints lead to a final 30 centimeter long hand model. The whole haptic phantom could be printed faultless within about 17 hours. The metamaterial consisting of the new unit cell results in an increased SUP share of 4.32%. Validated by an expert surgeon study, this allows in combination with a displacement of the uppermost skin layer a good palpability of the bones. Tracking of the hand marker in dodecahedron design works trouble-free in conjunction with a reference marker attached to the worktop of the training system. Conclusions: In this work, an optically tracked and haptically correct phantom hand was developed using dual-material 3D printing, which can be easily integrated into a surgical training system. KW - Handchirurgie KW - 3D-Druck KW - Lernprogramm KW - Zielverfolgung KW - HaptiVisT KW - Dual-material 3D printing KW - hand surgery training KW - metamaterial KW - tissue imitating phantom hand Y1 - 2020 U6 - https://doi.org/10.21037/qims.2019.12.03 N1 - Corresponding author: Christoph Palm VL - 10 IS - 02 SP - 340 EP - 455 PB - AME Publishing Company CY - Hong Kong, China ER - TY - JOUR A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph T1 - Imitating human soft tissue on basis of a dual-material 3D print using a support-filled metamaterial to provide bimanual haptic for a hand surgery training system JF - Quantitative Imaging in Medicine and Surgery N2 - Background: Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D-printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. Methods: The goal of this experiment is to imitate human soft tissue with its haptic and elasticity for a realistic hand phantom fabrication, using only a dual-material 3D printer and support-material-filled metamaterial between skin and bone. We present our workflow to generate lattice structures between hard bone and soft skin with iterative cube edge (CE) or cube face (CF) unit cells. Cuboid and finger shaped sample prints with and without inner hard bone in different lattice thickness are constructed and 3D printed. Results: The most elastic available rubber-like material is too firm to imitate soft tissue. By reducing the amount of rubber in the inner volume through support material (SUP), objects become significantly softer. Without metamaterial, after disintegration, the SUP can be shifted through the volume and thus the body loses its original shape. Although the CE design increases the elasticity, it cannot restore the fabric form. In contrast to CE, the CF design increases not only the elasticity but also guarantees a local limitation of the SUP. Therefore, the body retains its shape and internal bones remain in its intended place. Various unit cell sizes, lattice thickening and skin thickness regulate the rubber material and SUP ratio. Test prints with higher SUP and lower rubber material percentage appear softer and vice versa. This was confirmed by an expert surgeon evaluation. Subjects adjudged pure rubber-like material as too firm and samples only filled with SUP or lattice structure in CE design as not suitable for imitating tissue. 3D-printed finger samples in CF design were rated as realistic compared to the haptic of human tissue with a good palpable bone structure. Conclusions: We developed a new dual-material 3D print technique to imitate soft tissue of the human hand with its haptic properties. Blowy SUP is trapped within a lattice structure to soften rubber-like 3D print material, which makes it possible to reproduce a realistic replica of human hand soft tissue. KW - Dual-material 3D printing KW - Hand surgery training KW - Metamaterial KW - Support material KW - Tissue-imitating hand phantom KW - Handchirurgie KW - 3D-Druck KW - Biomaterial KW - Lernprogramm Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-979 N1 - Corresponding author: Christoph Palm VL - 9 IS - 1 SP - 30 EP - 42 PB - AME Publishing Company ER - TY - JOUR A1 - Weber, Karsten A1 - Dendorfer, Sebastian A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Schratzenstaller, Thomas A1 - Haug, Sonja A1 - Mohr, Christa A1 - Kiesl, Hans A1 - Drechsler, Jörg A1 - Westner, Markus A1 - Kobus, Jörn A1 - Schubert, Martin J. W. A1 - Zenger, Stefan A1 - Pietsch, Alexander A1 - Weiß, Josef A1 - Hinterseer, Sebastian A1 - Schieck, Roland A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Ringlstetter, Andreas A1 - Störl, Uta A1 - Bissyandé, Tegawendé F. A1 - Seeburger, Achim A1 - Schindler, Timo A1 - Ramsauer, Ralf A1 - Kiszka, Jan A1 - Kölbl, Andreas A1 - Lohmann, Daniel A1 - Mauerer, Wolfgang A1 - Maier, Johannes A1 - Scorna, Ulrike A1 - Palm, Christoph A1 - Soska, Alexander A1 - Mottok, Jürgen A1 - Ellermeier, Andreas A1 - Vögele, Daniel A1 - Hierl, Stefan A1 - Briem, Ulrich A1 - Buschmann, Knut A1 - Ehrlich, Ingo A1 - Pongratz, Christian A1 - Pielmeier, Benjamin A1 - Tyroller, Quirin A1 - Monkman, Gareth J. A1 - Gut, Franz A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian A1 - Langer, Christoph A1 - Schreiner, Rupert A1 - Huang, Yifeng A1 - She, Juncong A1 - Ottl, Andreas A1 - Rieger, Walter A1 - Kraml, Agnes A1 - Poxleitner, Thomas A1 - Hofer, Simon A1 - Heisterkamp, Benjamin A1 - Lerch, Maximilian A1 - Sammer, Nike A1 - Golde, Olivia A1 - Wellnitz, Felix A1 - Schmid, Sandra A1 - Muntschick, Claudia A1 - Kusterle, Wolfgang A1 - Paric, Ivan A1 - Brückl, Oliver A1 - Haslbeck, Matthias A1 - Schmidt, Ottfried A1 - Schwanzer, Peter A1 - Rabl, Hans-Peter A1 - Sterner, Michael A1 - Bauer, Franz A1 - Steinmann, Sven A1 - Eckert, Fabian A1 - Hofrichter, Andreas ED - Baier, Wolfgang T1 - Forschungsbericht 2017 T3 - Forschungsberichte der OTH Regensburg - 2017 KW - Forschung KW - Forschungsbericht Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13835 SN - 978-3-9818209-3-5 CY - Regensburg ER - TY - JOUR A1 - Mauerer, Wolfgang A1 - Rexhepaj, Tanja A1 - Monkman, Gareth J. A1 - Sindersberger, Dirk A1 - Diermeier, Andreas A1 - Neidhart, Thomas A1 - Wolfrum, Dominik A1 - Sterner, Michael A1 - Heberl, Michael A1 - Nusko, Robert A1 - Maier, Georg A1 - Nagl, Klaus A1 - Reuter, Monika A1 - Hofrichter, Andreas A1 - Lex, Thomas A1 - Lesch, Florian A1 - Kieninger, Bärbel A1 - Szalo, Alexander Eduard A1 - Zehner, Alexander A1 - Palm, Christoph A1 - Joblin, Mitchell A1 - Apel, Sven A1 - Ramsauer, Ralf A1 - Lohmann, Daniel A1 - Westner, Markus A1 - Strasser, Artur A1 - Munndi, Maximilian A1 - Ebner, Lena A1 - Elsner, Michael A1 - Weiß, Nils A1 - Segerer, Matthias A1 - Hackenberg, Rudolf A1 - Steger, Sebastian A1 - Schmailzl, Anton A1 - Dostalek, Michael A1 - Armbruster, Dominik A1 - Koch, Fabian A1 - Hierl, Stefan A1 - Thumann, Philipp A1 - Swidergal, Krzysztof A1 - Wagner, Marcus A1 - Briem, Ulrich A1 - Diermeier, Andreas A1 - Spreitzer, Stefan A1 - Beiderbeck, Sabrina A1 - Hook, Christian A1 - Zobel, Martin A1 - Weber, Tim A1 - Groß, Simon A1 - Penzkofer, Rainer A1 - Dendorfer, Sebastian A1 - Schillitz, Ingo A1 - Bauer, Thomas A1 - Rudolph, Clarissa A1 - Schmidt, Katja A1 - Liebetruth, Thomas A1 - Hamer, Markus A1 - Haug, Sonja A1 - Vernim, Matthias A1 - Weber, Karsten A1 - Saßmannshausen, Sean Patrick A1 - Books, Sebastian A1 - Neuleitner, Nikolaus A1 - Rechenauer, Christian A1 - Steffens, Oliver A1 - Kusterle, Wolfgang A1 - Gömmel, Roland A1 - Wellnitz, Felix A1 - Stierstorfer, Johannes A1 - Stadler, Dominik A1 - Hofmann, Matthias J. A1 - Motschmann, Hubert A1 - Shamonin (Chamonine), Mikhail A1 - Bleicher, Veronika A1 - Fischer, Sebastian A1 - Hackenberg, Rudolf A1 - Horn, Anton A1 - Kawasch, Raphael A1 - Petzenhauser, Michael A1 - Probst, Tobias A1 - Udalzow, Anton A1 - Dams, Florian A1 - Schreiner, Rupert A1 - Langer, Christoph A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian ED - Baier, Wolfgang T1 - Forschungsbericht 2016 T3 - Forschungsberichte der OTH Regensburg - 2016 Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13840 CY - Regensburg ER - TY - CHAP A1 - Maier, Johannes A1 - Huber, Michaela A1 - Katzky, Uwe A1 - Perret, Jerome A1 - Wittenberg, Thomas A1 - Palm, Christoph T1 - Force-Feedback-assisted Bone Drilling Simulation Based on CT Data T2 - Bildverarbeitung für die Medizin 2018; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 11. bis 13. März 2018 in Erlangen N2 - In order to fix a fracture using minimally invasive surgery approaches, surgeons are drilling complex and tiny bones with a 2 dimensional X-ray as single imaging modality in the operating room. Our novel haptic force-feedback and visual assisted training system will potentially help hand surgeons to learn the drilling procedure in a realistic visual environment. Within the simulation, the collision detection as well as the interaction between virtual drill, bone voxels and surfaces are important. In this work, the chai3d collision detection and force calculation algorithms are combined with a physics engine to simulate the bone drilling process. The chosen Bullet-Physics-Engine provides a stable simulation of rigid bodies, if the collision model of the drill and the tool holder is generated as a compound shape. Three haptic points are added to the K-wire tip for removing single voxels from the bone. For the drilling process three modes are proposed to emulate the different phases of drilling in restricting the movement of a haptic device. KW - Handchirurgie KW - Osteosynthese KW - Simulation KW - Lernprogramm Y1 - 2018 U6 - https://doi.org/10.1007/978-3-662-56537-7_78 SP - 291 EP - 296 PB - Springer CY - Berlin ER - TY - JOUR A1 - Maier, Johannes A1 - Perret, Jerome A1 - Simon, Martina A1 - Schmitt-Rüth, Stephanie A1 - Wittenberg, Thomas A1 - Palm, Christoph T1 - Force-feedback assisted and virtual fixtures based K-wire drilling simulation JF - Computers in Biology and Medicine N2 - One common method to fix fractures of the human hand after an accident is an osteosynthesis with Kirschner wires (K-wires) to stabilize the bone fragments. The insertion of K-wires is a delicate minimally invasive surgery, because surgeons operate almost without a sight. Since realistic training methods are time consuming, costly and insufficient, a virtual-reality (VR) based training system for the placement of K-wires was developed. As part of this, the current work deals with the real-time bone drilling simulation using a haptic force-feedback device. To simulate the drilling, we introduce a virtual fixture based force-feedback drilling approach. By decomposition of the drilling task into individual phases, each phase can be handled individually to perfectly control the drilling procedure. We report about the related finite state machine (FSM), describe the haptic feedback of each state and explain, how to avoid jerking of the haptic force-feedback during state transition. The usage of the virtual fixture approach results in a good haptic performance and a stable drilling behavior. This was confirmed by 26 expert surgeons, who evaluated the virtual drilling on the simulator and rated it as very realistic. To make the system even more convincing, we determined real drilling feed rates through experimental pig bone drilling and transferred them to our system. Due to a constant simulation thread we can guarantee a precise drilling motion. Virtual fixtures based force-feedback calculation is able to simulate force-feedback assisted bone drilling with high quality and, thus, will have a great potential in developing medical applications. KW - Handchirurgie KW - Osteosynthese KW - Operationstechnik KW - Lernprogramm KW - Virtuelle Realität KW - Medical training system KW - Virtual fixtures KW - Virtual reality KW - Force-feedback haptic KW - Minimally invasive hand surgery KW - K-wire drilling Y1 - 2019 U6 - https://doi.org/10.1016/j.compbiomed.2019.103473 N1 - Corresponding author: Christoph Palm VL - 114 SP - 1 EP - 10 PB - Elsevier ER - TY - THES A1 - Maier, Johannes T1 - Entwicklung eines Haptisch und Visuell unterstützten Trainingssystems (HaptiVisT) für komplexe Knochenbohrungen in der minimalinvasiven Handchirurgie N2 - Eine gängige Operationsmethode, um Frakturen der menschlichen Hand nach einem Unfall zu korrigieren, ist eine Osteosynthese mit sogenannten Kirschnerdrähten (K-Drähten) zur Stabilisierung von Knochenfragmenten. Die Einführung dieser langen, dünnen und scharfen Drähte durch manuelles Bohren ist eine komplexe minimalinvasive Operation, bei der ein Chirurg nahezu ohne visuelle Orientierung und nur durch eine kleine Öffnung der Haut des Patienten arbeitet. Als Orientierungshilfe für die optimale Lage der K-Drähte bleibt dem Chirurgen lediglich eine zweidimensionale (2D)-Röntgendarstellung und das Ertasten von knöchernen Vorsprüngen auf der menschlichen Hand, um Verletzungen an Risikostrukturen (Nerven, Gefäße usw.), die im Weichteilgewebe der Hand eingebettet sind, zu vermeiden. Für eine sichere und fehlerfreie Durchführung einer K-Draht-Osteosynthese ist deswegen eine gründliche theoretische und praktische Ausbildung junger Chirurgen notwendig. Da traditionelle Trainingsmethoden zeitaufwendig, kostspielig, ethisch nicht korrekt und unzureichend realistisch sind, wird in dieser Arbeit ein innovativer, auf virtueller Realität (VR) basierender, Haptisch und Visuell unterstützter Trainingssimulator (HaptiVisT) für die Platzierung von K-Drähten entwickelt, der vor allem Handchirurgen mit Übungs- und Perfektionierungsbedarf dabei unterstützt, das Bohrverfahren in einer realistischen aber virtuellen Umgebung zu erlernen. Beim HaptiVisT-Prototypenaufbau werden reale Patientendaten segmentierter Volumendaten aus einer Computertomographie (CT) und einer Magnetresonanztomographie (MRT) im virtuellen, dreidimensionalen (3D) Raum auf einem 3D-Monitor visualisiert und für eine intuitive bimanuelle Haptik sowohl mit einem Kraftfeedback-Gerät für den Bohrprozess und einer 3D-gedruckten und optisch getrackten Phantomhand kombiniert. Die vorliegende Arbeit beschreibt zunächst alle verwendeten Hardwaregeräte, die C++-Softwareumgebung, aufgebaut auf Multithreading (gleichzeitige Ausführung mehrerer Anweisungsfolgen in einem Prozess), und die auf Oberflächen- und Volumenrendering basierte Visualisierung. Die Kollisionsdetektion zwischen Bohrer und Knochen im virtuellen Raum wird in zwei separate Ereignisse unterteilt: Kollisionen zwischen Objekten als Gesamtes (Simulation der Kollision über die gesamte Objektoberfläche) und Kollisionen zwischen einer K-Draht-Spitze und dem Knochenvolumen für die Entfernung kleiner Volumenelemente (Voxel). Das Herzstück des Trainingssystems bildet eine echtzeitfähige Bohrsimulation, die den gesamten Bohrprozess in eine endliche Anzahl logischer Unterprozesse gliedert und diese Zustände in einen endlichen Zustandsautomaten (FSM, engl.: Finite State Machine) zusammenfasst. Das Kraftfeedback während einer Bohrung wird mit sogenannten „Virtual Fixtures“ (abstrakten sensorischen Informationen) berechnet und über einen Haptikarm auf den Benutzer übertragen. Damit die Simulation der Realität entspricht, wird unter Zuhilfenahme eines experimentellen Aufbaus die reale Bohrgeschwindigkeit durch kortikale Knochen ermittelt. Anschließend werden ein Levelkonzept und alle im System verfügbaren Bohrunterstützungswerkzeuge, wie haptische Korridore als Goldstandard oder eine Röntgenbildsimulation, vorgestellt. Mit ihnen ist es möglich, ausgesuchte Operationsfälle in Level unterschiedlicher Schwierigkeit zu unterteilen und den Operationsvorgang qualitativ zu bewerten. Der 3D-Druck einer Phantomhand (realitätsnahe Nachbildung einer Patientenhand) mit realistischen haptischen Eigenschaften zum Ertasten von Knochenvorsprüngen wird über einen metamaterialbasierten Ansatz (Neuanordnung des Grundmaterials durch eine künstlich angelegte, sich wiederholende Struktur) realisiert, da das aktuell am Markt verfügbare 3D-Druckmaterial für den Druck menschlichen Weichteilgewebes zu hart ist. Die Echtzeitverfolgung der Phantomhand beruht auf einem mit einer Stereokamera optisch getrackten Marker in Form eines Dodekaeders (Körper mit zwölf Flächen). Abschließend wird das HaptiVisT-Gesamtsystem in drei und der 3D-Druck einer Phantomhand in zwei Expertenevaluationen ausführlich untersucht und ausgewertet. Das HaptiVisT-System versteht sich als notwendiges Komplement für den ersten und weltweit einzigen funktionsfähigen, kompakten Prototypen für virtuelle K-DrahtOsteosynthesen mit haptischen Kraftfeedback, der in Zukunft Chirurgen in Aus- und Weiterbildung an Kliniken oder Trainingszentren ein risikofreies, zeit- und ortsunabhängiges Training ermöglicht. Die Kernelemente dieser Arbeit sind: • Stereoskopische 3D-Darstellung von realen Patientendaten. • Bimanuelle Haptik aus haptischen Kraftfeedback des Bohrens verbunden mit einer optisch getrackten, haptisch korrekten und 3D-gedruckten Phantomhand. • Zuverlässige Kollisionsdetektion zwischen virtuellen Objekten als Grundlage für das Kraftfeedback und die Abtragung von Knochen. • Echtzeitfähige Bohrsimulation durch Reduzierung des Bohrprozesses auf logische Bohr-Teilprozesse kombiniert mit einer Virtual Fixtures basierten Kraftberechnung. Haptisch korrekte Phantome sind vor allem im medizinischen Training von hoher Relevanz und die Berechnung des Kraftfeedbacks beruht erstmals auf der performanten und stabilen Simulation von Bohr-Teilprozessen unter Verwendung von Virtual Fixtures. Der Prototyp wird von Experten durchgehend positiv bewertet und bietet nach deren Einschätzung einen hohen Mehrwert für das chirurgische Training. Zukünftige Arbeiten könnten den Lerneffekt durch das HaptiVisT-Trainingssystem in stichhaltigen Evaluationen mit jungen Medizinstudenten unter Vorhandensein einer Kontrollgruppe statistisch validieren. Bei Bestätigung dieses Lerneffekts ist eine Ausgründung als eigenständiges Unternehmen und Weiterentwicklung des Prototyps mit Ausweitung auf weitere chirurgische Bereiche wie Knie- oder Hüftchirurgie denkbar. Unter Zuhilfenahme von automatischer Segmentierung könnten in Zukunft akut zu behandelnde Brüche abgebildet, vorab einer tatsächlichen Operation geübt und anschließend komplikationslos unter reduzierter Operationszeit durchgeführt werden. KW - Medizinisches Trainingssystem KW - Virtual Reality KW - Minimalinvasive Handchirurgie Y1 - 2020 SN - 978-3-8440-7547-2 N1 - Titel verleihende Institution: Universität Regensburg PB - Shaker CY - Düren ER - TY - CHAP A1 - Maier, Johannes A1 - Haug, Sonja A1 - Huber, Michaela A1 - Katzky, Uwe A1 - Neumann, Sabine A1 - Perret, Jérôme A1 - Prinzen, Martin A1 - Weber, Karsten A1 - Wittenberg, Thomas A1 - Wöhl, Rebecca A1 - Scorna, Ulrike A1 - Palm, Christoph T1 - Development of a haptic and visual assisted training simulation concept for complex bone drilling in minimally invasive hand surgery T2 - CARS Conference, 5.10.-7.10.2017 Y1 - 2017 ER - TY - GEN A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph ED - Handels, Heinz ED - Deserno, Thomas M. ED - Maier, Andreas ED - Maier-Hein, Klaus H. ED - Palm, Christoph ED - Tolxdorff, Thomas T1 - Abstract: Imitating Human Soft Tissue with Dual-Material 3D Printing T2 - Bildverarbeitung für die Medizin 2019, Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 17. bis 19. März 2019 in Lübeck N2 - Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. KW - Handchirurgie KW - 3D-Druck KW - Lernprogramm KW - HaptiVisT Y1 - 2019 SN - 978-3-658-25325-7 U6 - https://doi.org/10.1007/978-3-658-25326-4_48 SP - 218 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Wöhl, Rebecca A1 - Maier, Johannes A1 - Gehmert, Sebastian A1 - Palm, Christoph A1 - Riebschläger, Birgit A1 - Nerlich, Michael A1 - Huber, Michaela T1 - 3D Analysis of Osteosyntheses Material using semi-automated CT Segmentation BT - a case series of a 4 corner fusion plate JF - BMC Musculoskeletal Disorders N2 - Backround Scaphoidectomy and midcarpal fusion can be performed using traditional fixation methods like K-wires, staples, screws or different dorsal (non)locking arthrodesis systems. The aim of this study is to test the Aptus four corner locking plate and to compare the clinical findings to the data revealed by CT scans and semi-automated segmentation. Methods: This is a retrospective review of eleven patients suffering from scapholunate advanced collapse (SLAC) or scaphoid non-union advanced collapse (SNAC) wrist, who received a four corner fusion between August 2011 and July 2014. The clinical evaluation consisted of measuring the range of motion (ROM), strength and pain on a visual analogue scale (VAS). Additionally, the Disabilities of the Arm, Shoulder and Hand (QuickDASH) and the Mayo Wrist Score were assessed. A computerized tomography (CT) of the wrist was obtained six weeks postoperatively. After semi-automated segmentation of the CT scans, the models were post processed and surveyed. Results During the six-month follow-up mean range of motion (ROM) of the operated wrist was 60°, consisting of 30° extension and 30° flexion. While pain levels decreased significantly, 54% of grip strength and 89% of pinch strength were preserved compared to the contralateral healthy wrist. Union could be detected in all CT scans of the wrist. While X-ray pictures obtained postoperatively revealed no pathology, two user related technical complications were found through the 3D analysis, which correlated to the clinical outcome. Conclusion Due to semi-automated segmentation and 3D analysis it has been proved that the plate design can keep up to the manufacturers’ promises. Over all, this case series confirmed that the plate can compete with the coexisting techniques concerning clinical outcome, union and complication rate. KW - Handchirurgie KW - Osteosynthese KW - Arthrodese KW - 4FC KW - SLAC wrist KW - SNAC wrist KW - Semi-automated segmentation KW - 3D analysis KW - Computertomographie KW - Bildsegmentierung KW - Dreidimensionale Bildverarbeitung Y1 - 2018 U6 - https://doi.org/10.1186/s12891-018-1975-0 VL - 19 SP - 1 EP - 8 PB - Springer Nature ER -