TY - CHAP A1 - Hong, Jongman A1 - Hyun, Doosoo A1 - Kang, Tae-june A1 - Lee, Sang Bin A1 - Kral, Christian A1 - Haumer, Anton T1 - Detection and classification of rotor demagnetization and eccentricity faults for PM synchronous motors T2 - 2011 IEEE Energy Conversion Congress and Exposition (ECCE 2011) : Energy conversion innovation for a clean energy future ; Phoenix, Arizona, USA, 17.-22.09.2011 N2 - Condition monitoring of rotor problems such as demagnetization and eccentricity in permanent magnet synchronous motors (PMSM) is essential for guaranteeing high motor performance, efficiency, and reliability. However, there are many limitations to the off-line and on-line methods currently used for PMSM rotor quality assessment. In this paper, an inverter-embedded technique for automated detection and classification of PMSM rotor faults is proposed as an alternative. The main concept is to use the inverter to perform a test whenever the motor is stopped, to detect rotor faults independent of operating conditions or load torque oscillations, which is not possible with motor current signature analysis (MCSA). The d-axis is excited with a dc+ac signal, and the variation in the inductance pattern due to the change in the degree of magnetic saturation caused by demagnetization or eccentricity is observed for fault detection. An experimental study on a 7.5kW PMSM verifies that demagnetization and eccentricity can be detected and classified independent of the load with high sensitivity. KW - AC Machine KW - Condition Monitoring KW - d-axis Inductance KW - Demagnetization KW - Eccentricity KW - fault diagnosis KW - invertors KW - Magnetic Saturation KW - Permanent Magnet (PM) KW - permanent magnet motors KW - Synchronous Motor (SM) KW - synchronous motors Y1 - 2011 SN - 978-1-4577-0542-7 SN - 978-1-4577-0541-0 SN - 978-1-4577-0540-3 U6 - https://doi.org/10.1109/ECCE.2011.6064103 SN - 2329-3721 SN - 2329-3748 SP - 2512 EP - 2519 PB - IEEE CY - Piscataway, NJ ER - TY - CHAP A1 - Hong, Jongman A1 - Lee, Sang Bin A1 - Kral, Christian A1 - Haumer, Anton T1 - Detection of airgap eccentricity for permanent magnet synchronous motors based on the d-axis inductance T2 - 8th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics & Drives (SDEMPED), 2011 // 05. - 08.09.2011, Bologna, Italy N2 - The majority of the work performed for detecting eccentricity faults for permanent magnet synchronous motors (PMSM) focus on motor current signature analysis (MCSA), as it provides continuous on-line monitoring with existing current sensors. However, MCSA cannot be applied under nonstationary conditions and cannot distinguish faults with load torque oscillations, which are limitations for many PMSM drive applications. In this paper, it is shown that the d-axis inductance, L d , decreases with increase in the severity of eccentricity due to the change in the degree of magnetic saturation, and it is proposed as a new fault indicator. The inverter can be used to perform a standstill test automatically whenever the motor is stopped, to measure L d for eccentricity testing independent of load variations or oscillations, which is not possible with MCSA. An FE and experimental study on a 10hp PMSM verifies that eccentricity can be detected independent of the load with high sensitivity and reliability. KW - Airgap Eccentricity KW - Condition Monitoring KW - Diagnostics KW - fault location KW - inductance KW - load (electric) KW - machine testing KW - Magnetic Saturation KW - Motor Current Signature Analysis (MCSA) KW - permanent magnet motors KW - Permanent Magnet Synchronous Motor KW - synchronous motor protection Y1 - 2011 SN - 978-1-4244-9301-2 SN - 978-1-4244-9303-6 U6 - https://doi.org/10.1109/DEMPED.2011.6063651 SP - 378 EP - 384 PB - IEEE CY - Piscataway, NJ ER -