TY - CHAP A1 - Altmann, Robert A1 - Gebhard, Jürgen A1 - Troeger, Adrian A1 - Winkler, Markus A1 - Töpfer, Georg A1 - Remmele, Edgar A1 - Gaderer, Matthias A1 - Rabl, Hans-Peter ED - Berns, Karsten ED - Dressler, Klaus ED - Kalmar, Ralf ED - Stephan, Nicole ED - Teutsch, Roman ED - Thul, Martin T1 - Engine performance and emission analysis of a NRMM CI engine with common rail injection system operated with diesel fuel and rapeseed oil fuel T2 - Proceedings of the 6th Commercial Vehicle Technology Symposium 2020/2021 N2 - The use of alternative fuels in high-power non-road mobile machinery (NRMM) combustion engines is a possible way to substitute fossil fuel. By using pure vegetable oil fuels, like rapeseed oil fuel (DIN 51605), the greenhouse gases can be reduced effectively. Due to the differences in physical and chemical properties, a modification of the engine control unit calibration is necessary to adapt the working process on the fuel. Without modifications, the engine power output with rapeseed oil fuel is lower than with diesel fuel because of the smaller energy content. By adapting the engine settings, like the injection fuel mass, the power loss can be compensated but it accompanies with a higher fuel consumption. The engine emissions at part load conditions show, that there are benefits in particle emissions by using rapeseed oil at similar NOx emissions. Therefore, a design of experiment setup was initiated on a selected engine operation point to determine the effects of further parameters, like rail pressure, manifold pressure and injection pattern, on the process and to see the potential of an optimized calibration. KW - CI engine KW - common rail injection KW - Diesel Engine KW - DoE KW - rapeseed oil Y1 - 2021 SN - 978-3-658-29716-9 U6 - https://doi.org/10.1007/978-3-658-29717-6_16 SP - 231 EP - 242 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Gamisch, Bernd A1 - Gaderer, Matthias A1 - Dawoud, Belal T1 - On the Development of Thermochemical Hydrogen Storage: An Experimental Study of the Kinetics of the Redox Reactions under Different Operating Conditions JF - Applied Sciences N2 - This work aims at investigating the reduction/oxidation (redox) reaction kinetics on iron oxide pellets under different operating conditions of thermochemical hydrogen storage. In order to reduce the iron oxide pellets (90% Fe2O3, 10% stabilizing cement), hydrogen (H2) is applied in different concentrations with nitrogen (N2), as a carrier gas, at temperatures between between 700 ∘C and 900 ∘C, thus simulating the charging phase. The discharge phase is triggered by the flow of a mixture out of steam (H2O) and N2 at different concentrations in the same temperature range, resulting in the oxidizing of the previously reduced pellets. All investigations were carried out in a thermo-gravimetric analyzer (TGA) with a flow rate of 250mL/min. To describe the obtained kinetic results, a simplified analytical model, based on the linear driving force model, was developed. The investigated iron oxide pellets showed a stable redox performance of 23.8% weight reduction/gain, which corresponds to a volumetric storage density of 2.8kWh/(L bulk), also after the 29 performed redox cycles. Recalling that there is no H2 stored during the storage phase but iron, the introduced hydrogen storage technology is deemed very promising for applications in urban areas as day-night or seasonal storage for green hydrogen. KW - hydrogen storage KW - iron/iron oxide KW - reaction kinetics KW - redox reactions Y1 - 2021 U6 - https://doi.org/10.3390/app11041623 N1 - Corresponding author: Belal Dawoud VL - 11 IS - 4 SP - 1 EP - 15 PB - MDPI CY - Basel ER - TY - JOUR A1 - Gärtner, Sebastian A1 - Rank, Daniel A1 - Heberl, Michael A1 - Gaderer, Matthias A1 - Dawoud, Belal A1 - Haumer, Anton A1 - Sterner, Michael T1 - Simulation and Techno-Economic Analysis of a Power-to-Hydrogen Process for Oxyfuel Glass Melting JF - Energies N2 - As an energy-intensive industry sector, the glass industry is strongly affected by the increasingly stringent climate protection targets. As established combustion-based production systems ensure high process stability and glass quality, an immediate switch to low greenhouse gas emission processes is difficult. To approach these challenges, this work investigates a step-by-step integration of a Power-to-Hydrogen concept into established oxyfuel glass melting processes using a simulation approach. This is complemented by a case study for economic analysis on a selected German glass industry site by simulating the power production of a nearby renewable energy park and subsequent optimization of the power-to-hydrogen plant performance and capacities. The results of this study indicate, that the proposed system can reduce specific carbon dioxide emissions by up to 60%, while increasing specific energy demand by a maximum of 25%. Investigations of the impact of altered combustion and furnace properties like adiabatic flame temperature (+25 °C), temperature efficiency (∆ξ = −0.003) and heat capacity flow ratio (∆zHL = −0.009) indicate that pure hydrogen-oxygen combustion has less impact on melting properties than assumed so far. Within the case study, high CO2 abatement costs of 295 €/t CO2-eq. were determined. This is mainly due to the insufficient performance of renewable energy sources. The correlations between process scaling and economic parameters presented in this study show promising potential for further economic optimization of the proposed energy system in the future. KW - Power-to-Gas KW - Hydrogen KW - Electrolysis KW - Oxyfuel KW - Glass Industry Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-22713 N1 - Corresponding author: Sebastian Gärtner VL - 14 IS - 24 PB - MDPI ER - TY - JOUR A1 - Schwanzer, Peter A1 - Schillinger, Maximilian A1 - Mieslinger, Johann A1 - Walter, Stefanie A1 - Hagen, Gunter A1 - Maerkl, Susanne A1 - Haft, Gerhard A1 - Dietrich, Markus A1 - Moos, Ralf A1 - Gaderer, Matthias A1 - Rabl, Hans-Peter T1 - A Synthetic Ash-Loading Method for Gasoline Particulate Filters with Active Oil Injection JF - SAR International Journal of Engines N2 - To reduce particulate emissions, the use of particulate filters in diesel engines is meanwhile state of the art, while the integration of such systems in gasoline engines is now also necessary in order to comply with today's regulations. Over its lifetime, a gasoline particulate filter (GPF) collects ash components of fuel, lubrication oil, and materials originating from the catalytic coating and from engine abrasion. In the development and application process, synthetic ashing from GPFs is challenging. The ash of the lubrication oil can be increased in various ways, like oil-doped fuel, a separate oil burner, or changes in the piston-cylinder system of the engine. However, these methods show major disadvantages. For this reason, an improved approach is presented in this study, which allows a quick response to changes in combustion (e.g., engine knocking) and producing ash, which is more realistic due to its primary particle size and the density of ash plugs, in a shorter time. Therefore, an approach to accelerate ash loading by active oil injection using a multi-point injection (MPI) system is introduced. With the help of this methodology, an ashing capacity of 1.21 g/h is implemented, which is a high rate compared to other investigations. The primary particle size (evaluated by means of a transmission electron microscope), is in the same size range as those detected at the full-load curve during regular operation. A computer tomographic (CT) analysis of the incinerated particulate filter also shows that a very high density of ash plugs can be realized, which has also been found in the literature for real applications. In addition, with the help of a mass spectrometer (MS) and an intermediate weighing of the particulate filter, the current ash loading of the GPF could be determined with an accuracy of 1%. KW - Ash KW - GDI KW - GPF KW - Particle Y1 - 2021 U6 - https://doi.org/10.4271/03-14-04-0029 SN - 1946-3936 SN - 1946-3944 VL - 14 IS - 4 SP - 493 EP - 506 PB - SAE International ER - TY - JOUR A1 - Steininger, Peter A1 - Gaderer, Matthias A1 - Dawoud, Belal T1 - Assessment of the Annual Transmission Heat Loss Reduction of a Refurbished Existing Building with an Advanced Solar Selective Thermal Insulation System JF - Sustainability N2 - A numerical parameter sensitivity analysis of the design parameters of the recently published solar selective thermal insulation system (SATIS) has been carried out to enhance its thermal and optical properties. It turned out that the insulation properties of SATIS can be effectively improved by reducing the length of the glass closure element. Increasing the area share of the light conducting elements (LCEs) and decreasing their length-to-diameter (L/D) ratio were identified as key parameters in order to increase the solar gain. Two SATIS variants were compared with the same wall insulation without SATIS in a yearly energetic performance assessment. The SATIS variant with 10 mm length of the closure element, 44.2% area share of LCE, as well as front and rear diameters of 12 mm/9 mm shows an 11.8% lower transmission heat loss over the heating period than the wall insulation without SATIS. A new methodology was developed to enable the implementation of the computed solar gains of SATIS in 1D simulation tools. The result is a radiant heat flow map for integration as a heat source in 1D simulation models. A comparison between the 1D and 3D models of the inside wall heat fluxes showed an integral yearly agreement of 98%. KW - effective thermal conductivity KW - parameter sensitivity analysis KW - radiant heat flow map KW - solar selective thermal insulation system (SATIS) KW - total solar energy transmittance KW - yearly energetic performance assessment Y1 - 2021 U6 - https://doi.org/10.3390/su13137336 N1 - Corresponding author: Belal Dawoud VL - 13 IS - 13 SP - 1 EP - 19 PB - MDPI CY - Basel ER - TY - CHAP A1 - Steininger, Peter A1 - Gaderer, Matthias A1 - Dawoud, Belal T1 - Transient performance of a solar selective thermal insulation system T2 - 16th Advanced Building Skins Conference & Expo, 21 – 22/10/2021, Bern, Switzerland N2 - A prototype of a thermal insulation system to offer high selectivity of the solar gain regarding the solar incidence angle (SATIS) was applied to a typical solid brick masonry for existing buildings in Germany. Light conducting elements (LCEs) inclined at 19 ° were incorporated in SATIS, which equals the average solar noon angle in southern Germany during winter. The entire wall construction was experimentally investigated in a differential climatic chamber test bench at four different irradiation angles according to a dynamic test procedure. In addition, a conventional wall construction (CWC) has been measured. At SATIS’ design angle of 19 °, the SATIS wall construction shows a solar gain (SG) of 394.5 Wh/m², while the SG of the CWC amounts to only 25.4 Wh/m². The validated transient model of the SATIS wall construction showed that, at the end of the irradiation period of the dynamic test procedure (8 h), the solar heat penetrates to a depth of 253 mm and 111 mm inside the 385 mm thick brick wall masonry at the irradiation angles of 19 ° and 50 °, respectively. During the same time, the stored solar energy at 50 ° amounts to only 24.4 % of that stored at 19 °. Y1 - 2021 UR - https://www.researchgate.net/publication/355771950_Transient_performance_of_a_solar_selective_thermal_insulation_system PB - Advanced Buidling Skins GmbH ER - TY - JOUR A1 - Steininger, Peter A1 - Gaderer, Matthias A1 - Steffens, Oliver A1 - Dawoud, Belal T1 - Experimental and Numerical Study on the Heat Transfer Characteristics of a Newly-Developed Solar Active Thermal Insulation System JF - Buildings N2 - A newly-developed solar active thermal insulation system (SATIS) is introduced with the main objective to accomplish a highly-dependent total solar transmittance on the irradiation angle. SATIS is also designed to obtain the maximum transmittance at a prescribed design irradiation angle and to reduce it remarkably at higher irradiation angles. A purely mineral thermal insulation plaster with micro hollow glass spheres is applied to manufacture the investigated SATIS prototype. Light-conducting elements (LCEs) have been introduced into SATIS and suitable closing elements have been applied. The SATIS prototype has been investigated both experimentally and numerically. It turned out that the contributions of conduction, radiation and convection to the effective thermal conductivity of SATIS, without the closing elements (49 mWmK), amount to 86.2%, 13.2% and 0.6%, respectively. The angle-dependent short-wave radiation exchange within the LCE has been investigated via ray tracing. At the incidence angle of 19% (design angle), 27% of the radiation within the LCE is absorbed by the absorber plate, resulting in measured and computed total solar energy transmittances of 11.2%/11.7%, respectively. For a typical summer irradiation angle of 60%, 98% of the incident radiation is absorbed by the surfaces at the entrance of the LCE. The corresponding total solar energy transmittance amounts to 2.9%. KW - angle-dependent total solar energy transmittance KW - effective thermal conductivity KW - experimental investigation KW - numerical simulation KW - ray tracing KW - solar active thermal insulation system (SATIS) Y1 - 2021 U6 - https://doi.org/10.3390/buildings11030123 N1 - Corresponding author: Belal Dawoud VL - 11 IS - 3 SP - 1 EP - 22 PB - MDPI ER -