TY - JOUR A1 - Ebigbo, Alanna A1 - Mendel, Robert A1 - Scheppach, Markus W. A1 - Probst, Andreas A1 - Shahidi, Neal A1 - Prinz, Friederike A1 - Fleischmann, Carola A1 - Römmele, Christoph A1 - Gölder, Stefan Karl A1 - Braun, Georg A1 - Rauber, David A1 - Rückert, Tobias A1 - Souza Jr., Luis Antonio de A1 - Papa, João Paulo A1 - Byrne, Michael F. A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Vessel and tissue recognition during third-space endoscopy using a deep learning algorithm JF - Gut N2 - In this study, we aimed to develop an artificial intelligence clinical decision support solution to mitigate operator-dependent limitations during complex endoscopic procedures such as endoscopic submucosal dissection and peroral endoscopic myotomy, for example, bleeding and perforation. A DeepLabv3-based model was trained to delineate vessels, tissue structures and instruments on endoscopic still images from such procedures. The mean cross-validated Intersection over Union and Dice Score were 63% and 76%, respectively. Applied to standardised video clips from third-space endoscopic procedures, the algorithm showed a mean vessel detection rate of 85% with a false-positive rate of 0.75/min. These performance statistics suggest a potential clinical benefit for procedure safety, time and also training. KW - Artificial Intelligence KW - Endoscopy KW - Medical Image Computing Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-54293 VL - 71 IS - 12 SP - 2388 EP - 2390 PB - BMJ CY - London ER - TY - JOUR A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Muzalyova, Anna A1 - Rauber, David A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Yip, Hon Chi A1 - Lau, Louis Ho Shing A1 - Gölder, Stefan Karl A1 - Schmidt, Arthur A1 - Kouladouros, Konstantinos A1 - Abdelhafez, Mohamed A1 - Walter, Benjamin M. A1 - Meinikheim, Michael A1 - Chiu, Philip Wai Yan A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Artificial intelligence improves submucosal vessel detection during third space endoscopy JF - Endoscopy N2 - Background and study aims: While artificial intelligence (AI) shows high potential in decision support for diagnostic gastrointestinal endoscopy, its role in therapeutic endoscopy remains unclear. Third space endoscopic procedures pose the risk of intraprocedural bleeding. Therefore, we aimed to develop an AI algorithm for intraprocedural blood vessel detection. Patients and Methods: Using a test dataset with 101 standardized video clips containing 200 predefined submucosal blood vessels, 19 endoscopists were evaluated for the vessel detection rate (VDR) and time (VDT) with and without support of an AI algorithm. Test subjects were grouped according to experience in ESD. Results: With AI support, endoscopists VDR increased from 56.4% [CI 54.1–58.6] to 72.4% [CI 70.3–74.4]. Endoscopists‘ VDT dropped from 6.7sec [CI 6.2-7.1] to 5.2sec [CI 4.8-5.7]. False positive (FP) readings appeared in 4.5% of frames and were marked significantly shorter than true positives (6.0sec [CI 5.28-6.70] vs. 0.7sec [CI 0.55-0.87]). Conclusions: AI improved the vessel detection rate and time of endoscopists during third space endoscopy. While these data need to be corroborated by clinical trials, AI may prove to be an invaluable tool for the improvement of endoscopic interventions. KW - Artificial Intelligence KW - Third Space Endoscopy Y1 - 2025 U6 - https://doi.org/10.1055/a-2534-1164 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Scheppach, Markus W. A1 - Probst, Andreas A1 - Prinz, Friederike A1 - Schwamberger, Tanja A1 - Schlottmann, Jakob A1 - Gölder, Stefan Karl A1 - Walter, Benjamin A1 - Steinbrück, Ingo A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Einsatz von künstlicher Intelligenz (KI) als Entscheidungsunterstützungssystem für nicht-Experten bei der Beurteilung von Barrett-Ösophagus assoziierten Neoplasien (BERN) T2 - Zeitschrift für Gastroenterologie N2 - Einleitung Die sichere Detektion und Charakterisierung von Barrett-Ösophagus assoziierten Neoplasien (BERN) stellt selbst für erfahrene Endoskopiker eine Herausforderung dar. Ziel Ziel dieser Studie ist es, den Add-on Effekt eines künstlichen Intelligenz (KI) Systems (Barrett-Ampel) als Entscheidungsunterstüzungssystem für Endoskopiker ohne Expertise bei der Untersuchung von BERN zu evaluieren. Material und Methodik Zwölf Videos in „Weißlicht“ (WL), „narrow-band imaging“ (NBI) und „texture and color enhanced imaging“ (TXI) von histologisch bestätigten Barrett-Metaplasien oder BERN wurden von Experten und Untersuchern ohne Barrett-Expertise evaluiert. Die Probanden wurden dazu aufgefordert in den Videos auftauchende BERN zu identifizieren und gegebenenfalls die optimale Biopsiestelle zu markieren. Unser KI-System wurde demselben Test unterzogen, wobei dieses BERN in Echtzeit segmentierte und farblich von umliegendem Epithel differenzierte. Anschließend wurden den Probanden die Videos mit zusätzlicher KI-Unterstützung gezeigt. Basierend auf dieser neuen Information, wurden die Probanden zu einer Reevaluation ihrer initialen Beurteilung aufgefordert. Ergebnisse Die „Barrett-Ampel“ identifizierte unabhängig von den verwendeten Darstellungsmodi (WL, NBI, TXI) alle BERN. Zwei entzündlich veränderte Läsionen wurden fehlinterpretiert (Genauigkeit=75%). Während Experten vergleichbare Ergebnisse erzielten (Genauigkeit=70,8%), hatten Endoskopiker ohne Expertise bei der Beurteilung von Barrett-Metaplasien eine Genauigkeit von lediglich 58,3%. Wurden die nicht-Experten allerdings von unserem KI-System unterstützt, erreichten diese eine Genauigkeit von 75%. Zusammenfassung Unser KI-System hat das Potential als Entscheidungsunterstützungssystem bei der Differenzierung zwischen Barrett-Metaplasie und BERN zu fungieren und so Endoskopiker ohne entsprechende Expertise zu assistieren. Eine Limitation dieser Studie ist die niedrige Anzahl an eingeschlossenen Videos. Um die Ergebnisse dieser Studie zu bestätigen, müssen randomisierte kontrollierte klinische Studien durchgeführt werden. KW - Barrett-Ösophagus KW - Künstliche Intelligenz Y1 - 2022 U6 - https://doi.org/10.1055/s-0042-1745653 VL - 60 IS - 4 SP - 251 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Scheppach, Markus W. A1 - Probst, Andreas A1 - Prinz, Friederike A1 - Schwamberger, Tanja A1 - Schlottmann, Jakob A1 - Gölder, Stefan Karl A1 - Walter, Benjamin A1 - Steinbrück, Ingo A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - INFLUENCE OF AN ARTIFICIAL INTELLIGENCE (AI) BASED DECISION SUPPORT SYSTEM (DSS) ON THE DIAGNOSTIC PERFORMANCE OF NON-EXPERTS IN BARRETT´S ESOPHAGUS RELATED NEOPLASIA (BERN) T2 - Endoscopy N2 - Aims Barrett´s esophagus related neoplasia (BERN) is difficult to detect and characterize during endoscopy, even for expert endoscopists. We aimed to assess the add-on effect of an Artificial Intelligence (AI) algorithm (Barrett-Ampel) as a decision support system (DSS) for non-expert endoscopists in the evaluation of Barrett’s esophagus (BE) and BERN. Methods Twelve videos with multimodal imaging white light (WL), narrow-band imaging (NBI), texture and color enhanced imaging (TXI) of histologically confirmed BE and BERN were assessed by expert and non-expert endoscopists. For each video, endoscopists were asked to identify the area of BERN and decide on the biopsy spot. Videos were assessed by the AI algorithm and regions of BERN were highlighted in real-time by a transparent overlay. Finally, endoscopists were shown the AI videos and asked to either confirm or change their initial decision based on the AI support. Results Barrett-Ampel correctly identified all areas of BERN, irrespective of the imaging modality (WL, NBI, TXI), but misinterpreted two inflammatory lesions (Accuracy=75%). Expert endoscopists had a similar performance (Accuracy=70,8%), while non-experts had an accuracy of 58.3%. When AI was implemented as a DSS, non-expert endoscopists improved their diagnostic accuracy to 75%. Conclusions AI may have the potential to support non-expert endoscopists in the assessment of videos of BE and BERN. Limitations of this study include the low number of videos used. Randomized clinical trials in a real-life setting should be performed to confirm these results. KW - Artificial Intelligence KW - Barrett's Esophagus KW - Speiseröhrenkrankheit KW - Künstliche Intelligenz KW - Diagnose Y1 - 2022 U6 - https://doi.org/10.1055/s-00000012 VL - 54 IS - S 01 SP - S39 PB - Thieme ER - TY - GEN A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Muzalyova, Anna A1 - Rauber, David A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Yip, Hon Chi A1 - Lau, Louis Ho Shing A1 - Gölder, Stefan Karl A1 - Schmidt, Arthur A1 - Kouladouros, Konstantinos A1 - Abdelhafez, Mohamed A1 - Walter, B. A1 - Meinikheim, Michael A1 - Chiu, Philip Wai Yan A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Künstliche Intelligenz erhöht die Gefäßerkennung von Endoskopikern bei third space Endoskopie T2 - Zeitschrift für Gastroenterologie N2 - Einleitung: Künstliche Intelligenz (KI)-Algorithmen unterstützen Endoskopiker bei der Erkennung und Charakterisierung von Kolonpolypen in der klinischen Praxis und führen zu einer Erhöhung der Adenomdetektionsrate. Auch bei therapeutischen Maßnahmen wie der endoskopischen Submukosadissektion (ESD) könne relevante anatomische Strukturen durch KI mit hoher Genauigkeit erkannt und im endoskopischen Bild in Echtzeit markiert werden. Der Effekt einer solchen Applikation auf die Gefäßdetektion von Endoskopikern ist bislang nicht erforscht. Ziele:  In dieser Studie wurde der Effekt eines KI-Algorithmus zur Echtzeit-Gefäßmarkierung bei ESD auf die Gefäßdetektionsrate von Endoskopikern untersucht. Methodik:  59 third space Endoskopievideos wurde aus der Datenbank des Universitätsklinikums Augsburg extrahiert. Auf 5470 Einzelbildern dieser Untersuchungen wurde submukosale Blutgefäße annotiert. Zusammen mit weiteren 179681 unmarkierten Bildern wurde ein DeepLabV3+ neuronales Netzwerk mit einer semi-supervised learning Methode darin trainiert, submukosale Blutgefäße auf dem endoskopischen Bild zu erkennen und in Echtzeit einzuzeichnen. Anhand eines Videotests mit 101 Videoclips und 200 vordefinierten Blutgefäßen wurden 19 Endoskopiker mit und ohne KI Unterstützung getestet. Ergebnis:  Der Algorithmus erkannte in dem Videotest 93.5% der Gefäße in einer Detektionszeit von im Median 0,3 Sekunden. Die Gefäßdetektionsrate von Endoskopikern erhöhte sich durch KI Unterstützung von 56,4% auf 72,4% (p<0.001). Die Gefäßdetektionszeit reduzierte sich durch KI-Unterstützung von 6,7 auf 5.2 Sekunden (p<0.001). Der Algorithmus zeigte eine Rate an falsch positiven Detektionen in 4.5% der Einzelbilder. Falsch positiv erkannte Strukturen wurde kürzer detektiert, als richtig positive (0.7 und 6.0 Sekunden, p<0.001). Schlussfolgerung:  KI Unterstützung führte zu einer erhöhten Gefäßdetektionsrate und schnelleren Gefäßdetektionszeit von Endoskopikern. Ein möglicher klinischer Effekt auf die intraprozedurale Komplikationsrate oder Operationszeit könnte in prospektiven Studien ermittelt werden. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1790087 VL - 62 IS - 09 SP - e830 PB - Georg Thieme Verlag KG ER -