TY - JOUR A1 - Schermer, Detleff T1 - Design according to Eurocode 6 in practice JF - Mauerwerk N2 - For the structural design of masonry according to Eurocode 6 with the associated German national annex, the simplified method and the further simplified calculation method in Annex A are available. These procedures provide tools that can be used in practice to design standard cases quickly and easily. One feature of the verification of masonry walls under compressive loading is that no bending moments in the walls have to be determined as part of the determination of section forces and moments since the verification of the load-bearing capacity of the wall is based solely on the acting vertical force. The effects of floor end restraint and buckling are dealt with by simple equations. One new feature of verification according to Eurocode 6 is that the effect of partially supported floors on the load-bearing capacity of the wall can be included directly. The code is compact and simple to use and the further simplified calculation method is predestined for verification by manual calculation. T2 - Bemessung nach Eurocode 6 in der Praxis KW - buckling KW - calculation method KW - construction detailing KW - Eurocode 6 KW - masonry KW - structural design KW - floor bearing depth KW - further simplified Y1 - 2017 U6 - https://doi.org/10.1002/dama.201700719 SN - 1432-3427 SN - 1437-1022 VL - 21 IS - 1 PB - Ernst & Sohn, a Wiley brand ER - TY - JOUR A1 - Schermer, Detleff T1 - Bemessungsbeispiele - Nachweisführung nach dem vereinfachten Verfahren JF - Mauerwerk N2 - Die Regelungen im vereinfachten Verfahren von Eurocode 6, Teil 3 [4] mit dem zugehörigen Nationalen Anhang erlauben es, in wenigen Schritten rechnerische Nachweise von Mauerwerksbauteilen durchzuführen. Anhand mehrerer Bauteilnachweise aus der Praxis wird im Folgenden die Nachweisführung nach dem vereinfachten Verfahren dargestellt. Es ist erkennbar, dass bei Einhaltung der Anforderungen an das vereinfachte Verfahren sich die rechnerische Nachweisführung sehr einfach gestaltet und der größte Zeitaufwand in der Lastermittlung der einzelnen Bauteile liegt. Eine weitere Vereinfachung, die jedoch etwas stärkere Einschränkungen des Anwendungsbereiches bedingt, ist durch das im Anhang A angegebene sog. stark vereinfachte Verfahren gegeben. Y1 - 2014 U6 - https://doi.org/10.1002/dama.201400638 SN - 1432-3427 VL - 18 IS - 6 SP - 365 EP - 370 PB - Ernst & Sohn, a Wiley brand ER - TY - JOUR A1 - Schermer, Detleff A1 - Nagler, Florian A1 - Schwabe, Almut T1 - Archäologisches Haus am Petriplatz – massive Außenwandkonstruktion JF - Mauerwerk N2 - Petriplatz in Berlin is one of the earliest settlement sites in Berlin dating back to the 12th century. The Archaeological House is currently being built in this area on behalf of the Berlin Senate, which will integrate the finds associated with the site and make them directly accessible to visitors. The above-ground floors will serve as archaeological workshops and collection rooms and will feature a lecture hall. The chosen construction of the seven-storey building adapts to the local boundary conditions: Thus, the foundation is made on piles to minimize the intervention in the site and at the same time to create elements for geothermal energy. The static function as well as the fire protection requirements and the protection against external noise made it necessary to design the supporting structure-solidly in reinforced concrete. As a quasi-monolithic exterior wall structure in the standard area, a new system was developed by means of a load-bearing reinforced concrete inner shell and non-load-bearing infill of highly heat-insulating plane clay brick masonry. In addition to load transfer, particular -attention had to be paid to the issues of crack resistance, -execution and the interaction of concrete and masonry. T2 - Archaeological House at Petriplatz - massive outer wall-construction KW - archaeology KW - concrete KW - crack resistance KW - execution KW - masonry KW - multi-layer Y1 - 2021 U6 - https://doi.org/10.1002/dama.202100010 SN - 1437-1022 VL - 25 IS - 4 SP - 151 EP - 155 PB - Ernst & Sohn, a Wiley Brand ER - TY - JOUR A1 - Schermer, Detleff A1 - Meyer, Udo Joachim A1 - Lutman, Marjana A1 - Triller, Petra T1 - Shear tests on highly thermal insulating clay unit masonry walls with thin layer mortar JF - Mauerwerk N2 - The paper presents the results of a series of 6 shear tests on full scale highly thermal insulating clay unit masonry walls. The walls consisted of units with large voids filled with mineral wool with a thermal conductivity of lambda= 0,07 W/(m . K). The aim of the investigations was the verification of the in-planeshear resistance of this type of thermal insulating clay unit masonry in addition to the tests reported in [1]. The current design rules for clay unit masonry in DIN EN 1996-1-1/NA are rather conservative compared to the test results for thermal insulating units. KW - clay units KW - design KW - experimental testing KW - masonry with thin layer mortar KW - shear KW - thin layer mortar Y1 - 2019 U6 - https://doi.org/10.1002/dama.201900007 SN - 1432-3427 VL - 23 IS - 3 SP - 160 EP - 169 PB - Ernst & Sohn CY - Berlin ER - TY - GEN A1 - Schermer, Detleff ED - Schermer, Detleff ED - Brehm, Eric T1 - Mauerwerk-Kalender 2022 BT - Fassadengestaltung, Bauphysik, Innovationen KW - Mauerwerksbau KW - Mauerwerk KW - Kunststoffbauteil Y1 - 2022 SN - 978-3-433-03356-2 U6 - https://doi.org/10.1002/9783433611029 VL - 47 PB - Ernst & Sohn GmbH CY - Berlin ER - TY - GEN A1 - Schermer, Detleff ED - Schermer, Detleff ED - Brehm, Eric T1 - Mauerwerk-Kalender 2021 BT - Kunststoffverankerungen, Digitalisierung im Mauerwerksbau KW - Mauerwerksbau KW - Mauerwerk KW - Kunststoffbauteil Y1 - 2021 SN - 978-3-433-03293-0 U6 - https://doi.org/10.1002/9783433610732 VL - 2021 PB - Ernst & Sohn GmbH CY - Berlin ET - 46 ER - TY - JOUR A1 - Schermer, Detleff T1 - Bemessung nach Eurocode 6 JF - Deutsches Ingenieurblatt / Bauplaner Y1 - 2016 UR - https://www.ingenieurbau-online.de/fachartikel/artikeldetail/bemessung-nach-eurocode-6 SN - 0946-2422 SN - 2365-192X IS - 9, Supplement SP - 14 EP - 15 PB - Schiele & Schön CY - Berlin ER - TY - JOUR A1 - Schermer, Detleff T1 - Extrem beansprucht - der Sockelbereich monolithischer Wandkonstruktionen JF - BauPlaner Special Y1 - 2020 IS - 9 SP - 6 EP - 7 PB - Schiele & Schön CY - Berlin ER - TY - JOUR A1 - Schermer, Detleff T1 - Lösungen im Bereich Statik JF - Deutsches Ingenieurblatt Y1 - 2018 VL - 25 IS - 10 SP - 6 EP - 7 PB - Schiele & Schön CY - Berlin ER - TY - CHAP A1 - Schermer, Detleff ED - Zilch, Konrad ED - Diederichs, Claus Jürgen ED - Beckmann, Klaus J. ED - Gertz, Carsten ED - Malkwitz, Alexander ED - Moormann, Christian ED - Urban, Wilhelm ED - Valentin, Franz T1 - Bemessung von Mauerwerk T2 - Handbuch für Bauingenieure N2 - Die Bemessung von Mauerwerk deckt neben der Tragfähigkeit auch den Nachweis der Gebrauchstauglichkeit ab. Im Beitrag werden die Grundanforderungen und Hintergründe der Bemessung von Mauerwerk dargelegt und die Lösungen nach den aktuellen Vorschriften von Eurocode 6 und dem Nationalen Anhang erläutert. KW - Bemessung KW - Drucktragfähigkeit KW - Eurocode 6 KW - Genaueres Verfahren KW - Schnittgrößenermittlung KW - Schub KW - Spannungsblock KW - Unbewehrtes Mauerwerk KW - Vereinfachtes Verfahren Y1 - 2021 SN - 978-3-658-21749-5 U6 - https://doi.org/10.1007/978-3-658-21749-5_66-1 VL - 6 SP - 1 EP - 31 PB - Springer Fachmedien CY - Wiesbaden ER - TY - JOUR A1 - Schermer, Detleff T1 - The simplified calculation method of DIN EN 1996-3 in practice JF - Mauerwerk N2 - The design and detailing of masonry buildings was usually undertaken in the past using the simplified procedure in Section 6 of DIN 1053-1 (1996-11). With the changeover to the new European code, a new procedure has been made available with the simplified calculation method of DIN EN 1996-3, which promises similarly simple and safe handling for the user. The practical implementation of this new code has been underway for some time. The article investigates the standard design cases and explains the innovations and alterations compared to DIN 1053-1. T2 - Das vereinfachte Bemessungsverfahren von DIN EN 1996-3 in der Praxis Y1 - 2015 U6 - https://doi.org/10.1002/dama.201500682 VL - 19 IS - 6 SP - 471 EP - 478 PB - Wiley ER - TY - JOUR A1 - Schermer, Detleff T1 - Hybrid testing of masonry structures subjected to seismic loading JF - Mauerwerk N2 - The combination of experiments and numeric description in a test makes it possible to realistically investigate almost any type of system subjected to dynamic loading without requiring the extremely expensive device of a shaking table. With the numeric approach it is possible to examine the behaviour of even very large and complex structures, thus reducing the experimental investigations to the essential part of the system – for example, bracing masonry walls. This test method has proved to be very helpful, particularly for the investigation of seismic loading, and it allows the synchronous examination of several force and displacement variables (horizontal, vertical, rotational). A new laboratory is presented for the investigation of full-scale building structures up to three storeys high. Die Kombination von Experiment und numerischer Beschreibung innerhalb eines Versuches erlaubt die realitätsnahe Untersuchung annähernd beliebiger Systeme unter dynamischen Beanspruchungen, ohne den extrem hohen Aufwand von Rütteltischen zu erfordern. Durch die Numerik können auch sehr große und komplexe Strukturen mit ihrem Verhalten erfasst werden, wobei sich die versuchsmäßige Untersuchung auf den maßgebenden Teil des Systems – beispielsweise aussteifende Mauerwerkswände – beschränken kann. Insbesondere für Erdbebenbeanspruchung hat sich die Versuchsmethode sehr gut bewährt und es können mehrere Kraft- und Verschiebungsgrößen (horizontal, vertikal, Rotation) synchron behandelt werden. Für die Untersuchung an vollmaßstäblichen Gebäudestrukturen bis zu drei Geschossen wird ein neues Labor vorgestellt. T2 - Hybride Versuche an Mauerwerkskonstruktionen unter Erdbebenbeanspruchung Y1 - 2014 U6 - https://doi.org/10.1002/dama.201400625 SN - 1437-1022 SN - 1432-3427 VL - 18 IS - 3-4 SP - 206 EP - 212 PB - Ernst ; WILEY CY - Berlin ; Weinheim ER - TY - GEN A1 - Schermer, Detleff ED - Schermer, Detleff ED - Brehm, Eric T1 - Mauerwerk-Kalender 2023 BT - Schwerpunkte: Instandsetzung; Erdbeben; Lehmbau Y1 - 2023 SN - 978-3-433-03374-6 PB - Ernst & Sohn GmbH CY - Berlin ET - 48. Jahrgang ER - TY - GEN A1 - Schermer, Detleff T1 - Test set-up and proposed testing procedure for the determination of masonry walls under in-plane shear loadings : Brick and Block Masonry: Trends, Innovations and Challenges T2 - Proceedings of the 16th International Brick and Block Masonry Conference (IMAC), Padova, Italy, 26-30 June 2016 Y1 - 2016 SP - 1883 EP - 1888 PB - Routledge ER - TY - JOUR A1 - Schermer, Detleff A1 - Meyer, Udo Joachim A1 - Lutman, Marjana A1 - Triller, Petra T1 - Shear tests on full scale storey-height specimens constructed with thermally insulating clay unit masonry with thin-layer mortar JF - Mauerwerk N2 - The paper presents results of a series of 6 in-plane shear tests on storey-height clay unit masonry panels [1] with thin-layer mortar, carried out in addition to previous test campaigns [2], [3], and [4]. The walls were constructed with unfilled thermally insulating clay units with a thermal conductivity of lambda = 0.09 W/(m . K). The current design rules for clay unit masonry according to DIN EN 1996-1-1/NA [5] are conservative compared to the presented test results for thermally insulating clay unit masonry. KW - clay units KW - design KW - in-plane shear KW - test methods KW - thin-layer mortar KW - WALLS Y1 - 2019 U6 - https://doi.org/10.1002/dama.201900025 SN - 1432-3427 VL - 23 IS - 6 SP - 378 EP - 386 PB - Ernst & Sohn ER - TY - JOUR A1 - Schermer, Detleff A1 - Schmalz, Jonathan A1 - Meyer, Udo Joachim A1 - Gams, Matija A1 - Lutman, Marjana A1 - Triller, Petra T1 - Shear tests on thermal insulating clay unit masonry walls with thin layer mortar JF - Mauerwerk N2 - The paper presents the results of 20 shear tests on full scale thermal insulating clay unit masonry walls. The types of units used (units with large chambers filled with mineral wool pads and units with small corings filled with mineral wool granulate) as well as the tested wall geometries and vertical loads are representative of the most common wall constructions currently used in housing in Germany. The aim of the investigations was the verification of the shear -resistance of thermal insulating clay unit masonry under realistic conditions and comparison with the design rules in the codes and national technical approvals. The current design rules for clay unit masonry in DIN EN 1996-1-1/NA are rather conservative compared to the test results for thermal insulating units. KW - design KW - experimental testing KW - high precision clay masonry units KW - masonry with thin layer mortar KW - shear KW - thin layer mortar Y1 - 2018 U6 - https://doi.org/10.1002/dama.201800028 VL - 22 IS - 6 SP - 385 EP - 398 PB - Ernst & Sohn, a Wiley brand ER - TY - CHAP A1 - Schermer, Detleff ED - Zilch, Konrad T1 - Bemessung von Mauerwerk T2 - Konstruktiver Ingenieurbau und Hochbau: Technik, Organisation, Wirtschaftlichkeit. N2 - Die Bemessung von Mauerwerk deckt neben der Tragfähigkeit auch den Nachweis der Gebrauchstauglichkeit ab. Im Beitrag werden die Grundanforderungen und Hintergründe der Bemessung von Mauerwerk dargelegt und die Lösungen nach den aktuellen Vorschriften von Eurocode 6 und dem Nationalen Anhang erläutert. Y1 - 2024 SN - 978-3-658-29498-4 U6 - https://doi.org/10.1007/978-3-658-29498-4_66 SP - 443 EP - 473 PB - Springer Fachmedien CY - Wiesbaden ER - TY - GEN A1 - Meißner, Jonathan A1 - Schermer, Detleff A1 - Amberger, Franziska A1 - Hofmann, Philipp ED - Milani, Gabriele ED - Ghiassi, Bahman T1 - Eccentric partial compression tests on wall test specimens T2 - 18th International Brick and Block Masonry Conference : Proceedings of IB2MaC 2024 Volume 2, 21.-24. July 2024, Birmingham N2 - Within the scope of this work, the objective was to transfer the stress situations resulting at the exterior wall-floor joint as partial area loads to wall test specimens. The actual load-bearing capacities of highly thermally insulating plane clay unit masonry are to be quantified and compared with the calculated load-bearing capacities based on the unconfined stress-strain relationship and the linear-elastic, quasi-ductile and rigid-plastic material behaviour. In order to record also the deformations and compression at cross-section level directly in the load application area as well as the curvatures at system level, the deformations of all test specimens are documented by means of optical deformation measurement (digital image correlation). In this way, not only the load-bearing capacity but also, in particular, the stress resp. Strain distribution and stress redistributions as well as the experimental moment-curvature relationship can be quantified for the further analytical considerations and evaluations. Accordingly, it can be determined for all eccentric partial area loads that, regardless of the loading situation, higher load bearing capacities are achieved both compared to the calculated bearing capacity and based on a rigid-plastic material behaviour. Especially in the case of the loading situation at the bottom of the walls with partially supported floors, the activation of the unloaded cross-sectional zone at the load transfer can be shown very well based on the photogrammetrically determined cross-sectional compression. The decoupling initiated by the local discontinuity of the stress-strain state occurs only after the rigid-plastic cross-sectional bearing capacity is reached. Y1 - 2025 SN - 978-3-031-73309-3 U6 - https://doi.org/10.1007/978-3-031-73310-9_16 VL - 2025 SP - 223 EP - 238 PB - Springer ER - TY - CHAP A1 - Hofmann, Philipp A1 - Schermer, Detleff A1 - Amberger, Franziska A1 - Meißner, Jonathan ED - Ghiassi, Bahman ED - Milani, Gabriele T1 - Experimental investigation at the exterior wall-floor joint with partially supported slabs T2 - 18th International Brick and Block Masonry Conference : Proceedings of IB2MaC 2024 Volume 2, 21.-24. July 2024, Birmingham N2 - The objective of the extensive experimental investigations at the exterior wall-floor joint on a scale of 1:1 on highly thermally insulating clay unit masonry was to record the interaction between the acting axial force and the resulting slab rotation as a result of defined slab fixed end moments. The focus of this test series was on the influence of the nonlinear system behaviour at different axial force-moment combinations caused by the gaping of the horizontal joints as well as the contact zone between slab and masonry. With knowledge of the moment-rotation interaction as a function of the axial force of the wall, a numerical model can be developed with regard to the nonlinear system behaviour. Since the angle of rotation of the slab is of major importance in this respect, the structural design of a reinforced concrete slab is dispensed with in the test and replaced by a flexurally rigid solid steel bracket. This has the decisive advantage that the rotation of the steel bracket can be precisely detected by means of optical deformation measurement (digital image correlation) and directly assigned to the existing axial force-moment combinations. The evaluation of the tests has shown that the dominant nonlinear effect is essentially due to the gaping of the horizontal joints in the exterior wall-floor joint. During the test execution, the proportionality limit between the bracket moment and the bracket rotation could be successively increased with increasing load level regardless of the previous nonlinear system behaviour. Y1 - 2025 SN - 978-3-031-73309-3 U6 - https://doi.org/10.1007/978-3-031-73310-9_18 SP - 254 EP - 265 PB - Springer CY - Cham ER - TY - CHAP A1 - Meißner, Jonathan A1 - Schermer, Detleff A1 - Amberger, Franziska A1 - Hofmann, Philipp ED - Milani, Gabriele ED - Ghiassi, Bahman T1 - Experimental investigations on the influence of eccentric load application on the load bearing capacity of clay unit masonry walls T2 - 18th International Brick and Block Masonry Conference : Proceedings of IB2MaC 2024 Volume 2, 21.-24. July 2024, Birmingham N2 - For the analysis of centric and double-eccentric wall compression tests, a comprehensive database of different highly thermally insulating clay unit types is being compiled for the first time. The objective of the analysis is, on the one hand, to characterise the load-deformation behaviour of highly thermally insulating clay unit masonry and, on the other hand, to analyse the resulting stress distribution at the cross-section level. In addition, the influence of the increasing load inclination angle with decreasing test specimen slenderness is also shown. With regard to the wall compression tests under double-eccentric loading, the effects caused by the load inclination become obvious and lead to an average reduction of the load-bearing capacity of 41% compared to the centric compression tests. Furthermore, an opposite effect can also be observed with regard to the generally known interaction between decreasing specimen slenderness and increasing load-bearing capacity. According to this, lower load-bearing capacities result with constant eccentricity and decreasing slenderness, so that a back calculation to a uniform slenderness ratio with the relevant normalisation functions is not possible. The reason for this is due to the linearly increasing load inclination angle and the resulting increasing shear stress within the transverse webs. Y1 - 2025 SN - 978-3-031-73309-3 U6 - https://doi.org/10.1007/978-3-031-73310-9_17 SP - 239 EP - 253 PB - Springer CY - Cham ER -