TY - CHAP A1 - Dendorfer, Sebastian A1 - Maier, Hans Jürgen A1 - Hammer, Joachim T1 - How do age and anisotropy affect the fatigue behaviour of cancellous bone? T2 - Medicine Meets Engineering N2 - The fatigue behaviour of materials is of particular interest for the failure prediction of materials and structures exposed to cyclic loading. For trabecular bone structures only a few sets of lifetime data have been reported in the literature and structural measures are commonly not considered. The influence of load contributions not aligned with the main physiological axis remains unclear. Furthermore age effects on the fatigue behaviour are not well described. In the present study, different groups of human vertebral cancellous bone were exposed to cyclic compression. The inital modulus and therefore lifetimes were found to be highly dependent on age. The decrease in both with increasing age was much more pronounced in specimens which were not aligned with the main physiological axis. This implies that old bone is much more sensitive to (cyclic) failure loads in general but particularly to loads which are not coincident with the physiological main axis. KW - Knochenbruch KW - Spongiosa KW - Alter KW - Anisotropie Y1 - 2008 SP - 68 EP - 74 PB - IOS Press ER - TY - JOUR A1 - Dendorfer, Sebastian A1 - Gschoßman, Lukas T1 - Hightech in der Rehabiliation JF - BVOU Infobrief: Hightech in Orthopädie und Unfallchirurgie N2 - Aufgrund der steigenden Lebenserwartung und dem damit einhergehenden demographischen Wandel wird der Bedarf an Rehabilitations-Behandlungen in absehbarer Zukunft stark ansteigen. Ein Beispiel für diesen Trend ist die physiotherapeutische Behandlung nach Erhalt einer Knie-Totalendoprothese (Knie-TEP). So gehen Modellrechnungen basierend auf dem Bevölkerungswachstum und der bisherigen Prävalenz von Knie-TEPs davon aus, dass die Anzahl an durchgeführten Eingriffen in einkommensstarken Ländern wie Deutschland weiter zunehmen wird. Weiterhin stoßen traditionelle Rehabilitationsverfahren, gerade in strukturschwachen Regionen, schon heute an ihre Grenzen. Deutlich zu sehen war das während den Hochphasen der aktuellen Covid-19-Pandemie, als der Kontakt zwischen Therapeut*in und Patient*in flächendeckend eingeschränkt war. Eine erhöhte Nachfrage nach neuartigen Reha-Angeboten ist die logische Konsequenz. Innovative Konzepte sind daher dringend notwendig, um die daraus resultierenden technischen, sozialen und ökonomischen Herausforderungen zu bewältigen. Y1 - 2023 UR - https://www.bvou.net/infobrief-1-23/ SN - 2747-5913 IS - 1 SP - 9 EP - 11 PB - BVOU – Berufsverband für Orthopädie und Unfallchirurgie e.V. CY - Berlin ER - TY - CHAP A1 - Robie, Bruce A1 - Rasmussen, John A1 - Christensen, Soeren Toerholm A1 - Dendorfer, Sebastian T1 - Herniation Induces 55% Increase in Load of Key Stabilizing Muscle – Impact on Herniation Treatment Devices? T2 - Spine Arthoplasty Society Meeting, New Orleans, 2010 Y1 - 2010 ER - TY - JOUR A1 - Scheer, Clara A1 - Kubowitsch, Simone A1 - Dendorfer, Sebastian A1 - Jansen, Petra T1 - Happy Enough to Relax? How Positive and Negative Emotions Activate Different Muscular Regions in the Back - an Explorative Study JF - Frontiers in Psychology N2 - Embodiment theories have proposed a reciprocal relationship between emotional state and bodily reactions. Besides large body postures, recent studies have found emotions to affect rather subtle bodily expressions, such as slumped or upright sitting posture. This study investigated back muscle activity as an indication of an effect of positive and negative emotions on the sitting position. The electromyography (EMG) activity of six back muscles was recorded in 31 healthy subjects during exposure to positive and negative affective pictures. A resting period was used as a control condition. Increased muscle activity patterns in the back were found during the exposure to negative emotional stimuli, which was mainly measured in the lumbar and thorax regions. The positive emotion condition caused no elevated activity. The findings show that negative emotions lead to increased differential muscle activity in the back and thus corroborate those of previous research that emotion affects subtle bodily expressions. KW - electromyography KW - muscle activity KW - emotion KW - sadness KW - happiness KW - embodiment Y1 - 2021 U6 - https://doi.org/10.3389/fpsyg.2021.511746 SN - 1664-1078 VL - Volume 12 IS - May 2021 PB - Frontiers Media ER - TY - JOUR A1 - Weber, Tim A. A1 - Dendorfer, Sebastian A1 - Bulstra, Sjoerd K. A1 - Grifka, Joachim A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias T1 - Gait six month and one-year after computer assisted Femur First THR vs. conventional THR. Results of a patient- and observer- blinded randomized controlled trial JF - Gait & Posture N2 - A prospective randomized controlled trial is presented that is used to compare gait performance between the computer assisted Femur First (CAS FF) operation method and conventional THR (CON). 60 patients underwent a 3D gait analysis of the lower extremity at pre-operative, 6 months post-operative and twelve months post-operative. Detailed verification experiments were facilitated to ensure the quality of data as well as to avoid over-interpreting of the data. The results confirm a similar data-quality as reported in the literature. Walking speed, range of motion and symmetry thereof improved over the follow-up period, without significant differences between the groups. While all parameters do significantly increase over the follow-up period for both groups, there were no significant differences between them at any given time-point. Patients undergoing CAS FF showed a trend to improved hip flexion angle indicating a possible long-term benefit. KW - Biomechanics KW - Combined anteversion KW - Computer-assisted surgery KW - Femur first KW - Gait analysis Y1 - 2016 U6 - https://doi.org/10.1016/j.gaitpost.2016.06.035 VL - vol. 49 SP - 418 EP - 425 ER - TY - GEN A1 - Stein, Leonhard A1 - Schmitz, Paul A1 - Kretschmer, Rainer A1 - Dendorfer, Sebastian T1 - Gait parameter based fall risk scoring N2 - This study explored the connection between subjective self-assessed gait insecurities and objective movement scores. 93 subjects answered detailed fall risk questionnaires and performed functional tests. Significantly different movement patterns between fallers and non-fallers were found. Y1 - 2025 ER - TY - JOUR A1 - Weber, Karsten A1 - Dendorfer, Sebastian A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Schratzenstaller, Thomas A1 - Haug, Sonja A1 - Mohr, Christa A1 - Kiesl, Hans A1 - Drechsler, Jörg A1 - Westner, Markus A1 - Kobus, Jörn A1 - Schubert, Martin J. W. A1 - Zenger, Stefan A1 - Pietsch, Alexander A1 - Weiß, Josef A1 - Hinterseer, Sebastian A1 - Schieck, Roland A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Ringlstetter, Andreas A1 - Störl, Uta A1 - Bissyandé, Tegawendé F. A1 - Seeburger, Achim A1 - Schindler, Timo A1 - Ramsauer, Ralf A1 - Kiszka, Jan A1 - Kölbl, Andreas A1 - Lohmann, Daniel A1 - Mauerer, Wolfgang A1 - Maier, Johannes A1 - Scorna, Ulrike A1 - Palm, Christoph A1 - Soska, Alexander A1 - Mottok, Jürgen A1 - Ellermeier, Andreas A1 - Vögele, Daniel A1 - Hierl, Stefan A1 - Briem, Ulrich A1 - Buschmann, Knut A1 - Ehrlich, Ingo A1 - Pongratz, Christian A1 - Pielmeier, Benjamin A1 - Tyroller, Quirin A1 - Monkman, Gareth J. A1 - Gut, Franz A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian A1 - Langer, Christoph A1 - Schreiner, Rupert A1 - Huang, Yifeng A1 - She, Juncong A1 - Ottl, Andreas A1 - Rieger, Walter A1 - Kraml, Agnes A1 - Poxleitner, Thomas A1 - Hofer, Simon A1 - Heisterkamp, Benjamin A1 - Lerch, Maximilian A1 - Sammer, Nike A1 - Golde, Olivia A1 - Wellnitz, Felix A1 - Schmid, Sandra A1 - Muntschick, Claudia A1 - Kusterle, Wolfgang A1 - Paric, Ivan A1 - Brückl, Oliver A1 - Haslbeck, Matthias A1 - Schmidt, Ottfried A1 - Schwanzer, Peter A1 - Rabl, Hans-Peter A1 - Sterner, Michael A1 - Bauer, Franz A1 - Steinmann, Sven A1 - Eckert, Fabian A1 - Hofrichter, Andreas ED - Baier, Wolfgang T1 - Forschungsbericht 2017 T3 - Forschungsberichte der OTH Regensburg - 2017 KW - Forschung KW - Forschungsbericht Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13835 SN - 978-3-9818209-3-5 CY - Regensburg ER - TY - JOUR A1 - Mauerer, Wolfgang A1 - Rexhepaj, Tanja A1 - Monkman, Gareth J. A1 - Sindersberger, Dirk A1 - Diermeier, Andreas A1 - Neidhart, Thomas A1 - Wolfrum, Dominik A1 - Sterner, Michael A1 - Heberl, Michael A1 - Nusko, Robert A1 - Maier, Georg A1 - Nagl, Klaus A1 - Reuter, Monika A1 - Hofrichter, Andreas A1 - Lex, Thomas A1 - Lesch, Florian A1 - Kieninger, Bärbel A1 - Szalo, Alexander Eduard A1 - Zehner, Alexander A1 - Palm, Christoph A1 - Joblin, Mitchell A1 - Apel, Sven A1 - Ramsauer, Ralf A1 - Lohmann, Daniel A1 - Westner, Markus A1 - Strasser, Artur A1 - Munndi, Maximilian A1 - Ebner, Lena A1 - Elsner, Michael A1 - Weiß, Nils A1 - Segerer, Matthias A1 - Hackenberg, Rudolf A1 - Steger, Sebastian A1 - Schmailzl, Anton A1 - Dostalek, Michael A1 - Armbruster, Dominik A1 - Koch, Fabian A1 - Hierl, Stefan A1 - Thumann, Philipp A1 - Swidergal, Krzysztof A1 - Wagner, Marcus A1 - Briem, Ulrich A1 - Diermeier, Andreas A1 - Spreitzer, Stefan A1 - Beiderbeck, Sabrina A1 - Hook, Christian A1 - Zobel, Martin A1 - Weber, Tim A1 - Groß, Simon A1 - Penzkofer, Rainer A1 - Dendorfer, Sebastian A1 - Schillitz, Ingo A1 - Bauer, Thomas A1 - Rudolph, Clarissa A1 - Schmidt, Katja A1 - Liebetruth, Thomas A1 - Hamer, Markus A1 - Haug, Sonja A1 - Vernim, Matthias A1 - Weber, Karsten A1 - Saßmannshausen, Sean Patrick A1 - Books, Sebastian A1 - Neuleitner, Nikolaus A1 - Rechenauer, Christian A1 - Steffens, Oliver A1 - Kusterle, Wolfgang A1 - Gömmel, Roland A1 - Wellnitz, Felix A1 - Stierstorfer, Johannes A1 - Stadler, Dominik A1 - Hofmann, Matthias J. A1 - Motschmann, Hubert A1 - Shamonin (Chamonine), Mikhail A1 - Bleicher, Veronika A1 - Fischer, Sebastian A1 - Hackenberg, Rudolf A1 - Horn, Anton A1 - Kawasch, Raphael A1 - Petzenhauser, Michael A1 - Probst, Tobias A1 - Udalzow, Anton A1 - Dams, Florian A1 - Schreiner, Rupert A1 - Langer, Christoph A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian ED - Baier, Wolfgang T1 - Forschungsbericht 2016 T3 - Forschungsberichte der OTH Regensburg - 2016 Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13840 CY - Regensburg ER - TY - JOUR A1 - Beimler, Josef A1 - Leißl, Caroline A1 - Ebner, Lena A1 - Elsner, Michael A1 - Mühlbauer, Gerhard A1 - Kohlert, Dieter A1 - Schubert, Martin J. W. A1 - Weiß, Andreas P. A1 - Sterner, Michael A1 - Raith, Thomas A1 - Afranseder, Martin A1 - Krapf, Tobias A1 - Mottok, Jürgen A1 - Siemers, Christian A1 - Großmann, Benjamin A1 - Höcherl, Johannes A1 - Schlegl, Thomas A1 - Schneider, Ralph A1 - Milaev, Johannes A1 - Rampelt, Christina A1 - Roduner, Christian A1 - Glowa, Christoph A1 - Bachl, Christoph A1 - Schliekmann, Claus A1 - Gnan, Alfons A1 - Grill, Martin A1 - Ruhland, Karl A1 - Piehler, Thomas A1 - Friers, Daniel A1 - Wels, Harald A1 - Pflug, Kenny A1 - Kucera, Markus A1 - Waas, Thomas A1 - Schlachetzki, Felix A1 - Boy, Sandra A1 - Pemmerl, Josef A1 - Leis, Alexander A1 - Welsch, Andreas F.X. A1 - Graf, Franz A1 - Zenger, Gerhard A1 - Volbert, Klaus A1 - Waas, Thomas A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Störl, Uta A1 - Heyl, C. A1 - Boldenko, A. A1 - Monkman, Gareth J. A1 - Kujat, Richard A1 - Briem, Ulrich A1 - Hierl, Stefan A1 - Talbot, Sebastian A1 - Schmailzl, Anton A1 - Ławrowski, Robert Damian A1 - Prommesberger, Christian A1 - Langer, Christoph A1 - Dams, Florian A1 - Schreiner, Rupert A1 - Valentino, Piergiorgio A1 - Romano, Marco A1 - Ehrlich, Ingo A1 - Furgiuele, Franco A1 - Gebbeken, Norbert A1 - Eisenried, Michael A1 - Jungbauer, Bastian A1 - Hutterer, Albert A1 - Bauhuber, Michael A1 - Mikrievskij, Andreas A1 - Argauer, Monika A1 - Hummel, Helmut A1 - Lechner, Alfred A1 - Liebetruth, Thomas A1 - Schumm, Michael A1 - Joseph, Saskia A1 - Reschke, Michael A1 - Soska, Alexander A1 - Schroll-Decker, Irmgard A1 - Putzer, Michael A1 - Rasmussen, John A1 - Dendorfer, Sebastian A1 - Weber, Tim A1 - Al-Munajjed, Amir Andreas A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias A1 - Haug, Sonja A1 - Rudolph, Clarissa A1 - Zeitler, Annika A1 - Schaubeck, Simon A1 - Steffens, Oliver A1 - Rechenauer, Christian A1 - Schulz-Brize, Thekla A1 - Fleischmann, Florian A1 - Kusterle, Wolfgang A1 - Beer, Anne A1 - Wagner, Bernd A1 - Neidhart, Thomas ED - Baier, Wolfgang T1 - Forschungsbericht 2013 T3 - Forschungsberichte der OTH Regensburg - 2013 Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-7990 CY - Regensburg ER - TY - JOUR A1 - Lautenschläger, Toni A1 - Leis, Alexander A1 - Dendorfer, Sebastian A1 - Palm, Christoph A1 - Schreiner, Rupert A1 - Langer, Christoph A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian A1 - Dams, Florian A1 - Bornmann, Benjamin A1 - Navitski, Aliaksandr A1 - Serbun, Pavel A1 - Müller, Günter A1 - Liebetruth, Thomas A1 - Kohlert, Dieter A1 - Pernsteiner, Jochen A1 - Schreier, Franz A1 - Heerklotz, Sabrina A1 - Heerklotz, Allwin A1 - Boos, Alexander A1 - Herwald, Dominik A1 - Monkman, Gareth J. A1 - Treiber, Daniel A1 - Mayer, Matthias A1 - Hörner, Eva A1 - Bentz, Alexander A1 - Shamonin (Chamonine), Mikhail A1 - Johansen, Søren Peter A1 - Reichel, Marco A1 - Stoll, Andrea A1 - Briem, Ulrich A1 - Dullien, Silvia A1 - Renkawitz, Tobias A1 - Weber, Tim A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Penzkofer, Rainer A1 - Barnsteiner, K. A1 - Jovanovik, M. A1 - Wernecke, P. A1 - Vögele, A. A1 - Bachmann, T. A1 - Plötz, Martin A1 - Schliekmann, Claus A1 - Wels, Harald A1 - Helmberger, Paul A1 - Kaspar, Marcel A1 - Hönicka, M. A1 - Schrammel, Siegfried A1 - Enser, Markus A1 - Schmidmeier, Monika A1 - Schroll-Decker, Irmgard A1 - Haug, Sonja A1 - Gelfert, Verena A1 - Vernim, Matthias ED - Baier, Wolfgang T1 - Forschungsbericht 2012 T3 - Forschungsberichte der OTH Regensburg - 2012 Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-7834 CY - Regensburg ER - TY - JOUR A1 - Broser, Christian A1 - Falter, Thomas A1 - Ławrowski, Robert Damian A1 - Altenbuchner, Amelie A1 - Vögele, Daniel A1 - Koss, Claus A1 - Schlamp, Matthias A1 - Dunnweber, Jan A1 - Steffens, Oliver A1 - Heckner, Markus A1 - Jaritz, Sabine A1 - Schiegl, Thomas A1 - Corsten, Sabine A1 - Lauer, Norina A1 - Guertler, Katherine A1 - Koenig, Eric A1 - Haug, Sonja A1 - Huber, Dominik A1 - Birkenmaier, Clemens A1 - Krenkel, Lars A1 - Wagner, Thomas A1 - Justus, Xenia A1 - Saßmannshausen, Sean Patrick A1 - Kleine, Nadine A1 - Weber, Karsten A1 - Braun, Carina N. A1 - Giacoppo, Giuliano A1 - Heinrich, Michael A1 - Just, Tobias A1 - Schreck, Thomas A1 - Schnabl, Andreas A1 - Gilmore, Amador Téran A1 - Roeslin, Samuel A1 - Schmid, Sandra A1 - Wellnitz, Felix A1 - Malz, Sebastian A1 - Maurial, Andreas A1 - Hauser, Florian A1 - Mottok, Jürgen A1 - Klettke, Meike A1 - Scherzinger, Stefanie A1 - Störl, Uta A1 - Heckner, Markus A1 - Bazo, Alexander A1 - Wolff, Christian A1 - Kopper, Andreas A1 - Westner, Markus A1 - Pongratz, Christian A1 - Ehrlich, Ingo A1 - Briem, Ulrich A1 - Hederer, Sebastian A1 - Wagner, Marcus A1 - Schillinger, Moritz A1 - Görlach, Julien A1 - Hierl, Stefan A1 - Siegl, Marco A1 - Langer, Christoph A1 - Hausladen, Matthias A1 - Schreiner, Rupert A1 - Haslbeck, Matthias A1 - Kreuzer, Reinhard A1 - Brückl, Oliver A1 - Dawoud, Belal A1 - Rabl, Hans-Peter A1 - Gamisch, Bernd A1 - Schmidt, Ottfried A1 - Heberl, Michael A1 - Gänsbauer, Bianca A1 - Bick, Werner A1 - Ellermeier, Andreas A1 - Monkman, Gareth J. A1 - Prem, Nina A1 - Sindersberger, Dirk A1 - Tschurtschenthaler, Karl A1 - Aurbach, Maximilian A1 - Dendorfer, Sebastian A1 - Betz, Michael A. A1 - Szecsey, Tamara A1 - Mauerer, Wolfgang A1 - Murr, Florian ED - Baier, Wolfgang T1 - Forschung 2018 T3 - Forschungsberichte der OTH Regensburg - 2018 KW - Forschung KW - Forschungsbericht Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13826 SN - 978-3-9818209-5-9 CY - Regensburg ER - TY - CHAP A1 - Dendorfer, Sebastian A1 - Englert, Carsten T1 - Forces on a clavicles midshaft fracture and influence of fracture type T2 - AO Symposium, Regensburg, 2009 Y1 - 2009 ER - TY - CHAP A1 - Al-Munajjed, Amir Andreas A1 - Nolte, Daniel A1 - Rasmussen, John A1 - Dendorfer, Sebastian T1 - Force distribution in the foot during braking – a musculoskeletal approach T2 - Human Modeling Symposium 2014, Munich, Germany N2 - High loads can appear in the individual joints of the human foot while the driver uses the pedals, in particular, during breaking. Measuring these internal forces is very difficult or almost impossible; therefore, advanced models are necessary to perform musculoskeletal simulations. The objective of this investigation was to see what loads are acting in the individual foot joints from the phalanges to calcaneus and talus during different brake scenarios. The Glasgow-Maastricht AnyBody Foot Model with 26 separate segments, connected by joints, ligaments and muscles was used inside the AnyBody Modeling System to compute individual mid foot joint loads. The amount, the direction of the force and additionally also the load insertion point was varied for several simulations. Figure 1: Seated musculoskeletal body model with applied brake force and forces for the lateral, intermediate and medial cuneiform-navicular joint for two different brake forces. The simulation showed that for the different brake scenarios, different muscles will be activated in the human and therefore different loads are apply in the fore-and mid-foot, respectively. The torso of the subject was assumed to be fixed in the seat. Further studies are ongoing to simulate the seat as an elastic element that allows different H-point locations according to the different loadings in the foot from the brake pedal using a new inverse dynamics analysis method called force-dependent kinematics. Y1 - 2014 UR - https://www.researchgate.net/publication/281229902_Force_distribution_in_the_foot_during_braking_-a_musculoskeletal_approach ER - TY - CHAP A1 - Jungtäubl, Dominik A1 - Schmitz, Paul A1 - Gross, Simon A1 - Dendorfer, Sebastian ED - Badnjevic, Almir T1 - FEA of the transiliacal internal fixator as an osteosynthesis of pelvic ring fractures T2 - CMBEBIH 2017, Proceedings of the International Conference on Medical and Biological Engineering 2017 N2 - Common Schanz screw systems can be used to stabilize pelvic ring fractures. In order to accommodate for different patient’s requirements, implants can be placed in cranio-caudal direction into the os ilium (T1), or into the supraacetabular bone canal, and thus, in dorso-ventral direction (T2). Whereas both techniques are currently used, no data of the biomechanical behavior is available up to this date. The aim of this study is to analyze, whether T2 shows biomechanical advantages with respect to tissue and implant stresses due to the enlarged bone-implant interface. Forces acting on the pelvis were analyzed using motion capture data of a gait cycle obtained by the utilization of a musculoskeletal simulation program. A three dimensional finite element (FE) model of the pelvis with grayscale-based material properties was generated. The muscle and joint reaction forces at toe-off were applied to the FE model and instable pelvis fractures were implemented. The osteosynthesis systems were positioned within the model in order to enable the comparison between the two different surgical techniques. Stresses and displacements were analyzed for bone tissue, fracture zone and implant. T2 lead to approx. 30% larger displacements in the fracture zone. Von-Mises stresses were larger for T2 in the implant (80 MPa vs. 227 MPa), whereas T1 leads to larger stresses in the bone tissue (200 MPa vs. 140 MPa). Both implantation techniques showed a good biomechanical behavior. Differences could be found with respect to tissue strains and deformations in the fracture zone. If bone quality or fracture healing are of concern, T2 or T1 should be used, respectively. However, both techniques seem to be applicable for cases with no special requirements. Further analyses aim to investigate the behavior under cyclic loading. KW - Finite element analysis KW - Musculoskeletal simulation KW - Internal fixator KW - Pelvic ring fracture KW - Beckenbruch KW - Operationstechnik KW - Finite-Elemente-Methode KW - Biomechanik KW - Simulation Y1 - 2017 SN - 978-981-10-4165-5 U6 - https://doi.org/10.1007/978-981-10-4166-2_32 SP - 212 EP - 217 PB - Springer CY - Singapore ER - TY - JOUR A1 - Dendorfer, Sebastian A1 - Maier, Hans Jürgen A1 - Hammer, Joachim T1 - Fatigue damage in cancellous bone: an experimental approach from continuum to micro scale JF - Journal of the Mechanical Behavior of Biomedical Materials N2 - Repeated loadings may cause fatigue fractures in bony structures. Even if these failure types are known, data for trabecular bone exposed to cyclic loading are still insufficient as the majority of fatigue analyses on bone concentrate on cortical structures. Despite its highly anisotropic and inhomogeneous structure, trabecular bone is treated with continuum approaches in fatigue analyses. The underlying deformation and damage mechanism within trabecular specimens are not yet sufficiently investigated. In the present study different types of trabecular bone were loaded in monotonic and cyclic compression. In addition to the measurement of integral specimen deformations, optical deformation analysis was employed in order to obtain strain distributions at different scale levels, from the specimens' surface to the trabeculae level. These measurements allowed for the possibility of linking the macroscopic and microscopic mechanical behaviour of cancellous bone. Deformations were found to be highly inhomogeneous across the specimen. Furthermore strains were found to already localise at very low load levels and after few load cycles. Microcracks in individual trabeculae were induced in the very early stage of cyclic testing. The results provide evidence of the capability of the method to supply essential data on the failure behaviour of individual trabeculae in future studies. KW - Knochen KW - Spongiosa KW - Ermüdungsbruch KW - Fatigue KW - Cancellous bone KW - Deformation behaviour KW - Damage KW - Measurement and testing KW - Mechanical behaviour Y1 - 2009 U6 - https://doi.org/10.1016/j.jmbbm.2008.03.003 VL - 2 IS - 1 SP - 113 EP - 119 ER - TY - CHAP A1 - Dendorfer, Sebastian A1 - Penzkofer, Rainer T1 - Experimentelle Untersuchung der Belastungen im Kopf beim Treten T2 - Fachsymposium "Treten gegen den Kopf", April 2013, Nürnberg Y1 - 2013 ER - TY - CHAP A1 - Pilling, A. A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Dendorfer, Sebastian T1 - Experimental workflow for determining psychological stress from physiological biosignals T2 - Jahrestagung der BIOMEDIZINISCHEN TECHNIK und Dreiländertagung der MEDIZINISCHEN PHYSIK, Dresden, Germany, 2017 Y1 - 2017 ER - TY - GEN A1 - Brandt, Hanna A1 - Steinhilber, Bernd A1 - Dendorfer, Sebastian A1 - Pfingsten, Andrea T1 - Exoskelettale Unterstützung in der Pflege - eine Untersuchung der Muskelaktivität, des Hüftflexionswinkels und des subjektiven Belastungsempfinden bei einem simulierten Transfer. T2 - Physioscience N2 - Die dargestellten Ergebnisse weisen darauf hin, dass das in der Studie verwendete passive rückenunterstützende Exoskelett die (wahrgenommene) körperliche Belastung beim dynamischen Transfer eines 45 kg schweren Dummys potenziell reduzieren kann und sich der maximale Hüftgelenksflexionswinkel mit Exo verkleinert. Dieses Ergebnis deckt sich mit bereits publizierten Studienergebnissen von Arbeitsaufgaben im Bereich des Hebens und Tragens von Gegenständen aus der Logistik Y1 - 2025 U6 - https://doi.org/10.1055/s-0045-1808226 VL - 21 IS - S 01 SP - S61 EP - S62 PB - Thieme ER - TY - JOUR A1 - Aurbach, Maximilian A1 - Spicka, Jan A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Evaluation of musculoskeletal modelling parameters of the shoulder complex during humeral abduction above 90° JF - Journal of Biomechanics N2 - Based on electromyographic data and force measurements within the shoulder joint, there is an indication that muscle and resulting joint reaction forces keep increasing over an abduction angle of 90°. In inverse dynamics models, no single parameter could be attributed to simulate this force behaviour accordingly. The aim of this work is to implement kinematic, kinetic and muscle model modifications to an existing model of the shoulder (AnyBody™) and assess their single and combined effects during abduction up to 140° humeral elevation. The kinematics and the EMG activity of 10 test subjects were measured during humeral abduction. Six modifications were implemented in the model: alternative wrapping of the virtual deltoid muscle elements, utilization of a three element Hill model, strength scaling, motion capture driven clavicle elevation/protraction, translation of the GH joint in dependency of the acting forces and an alteration of the scapula/clavicle rhythm. From the six modifications, 16 different combinations were considered. Parameter combinations with the Hill model changed the resultant GH joint reaction force and led to an increase in force during abduction of the humerus above 90°. Under the premise of muscle activities and forces within the GH joint rising after 90° of humeral abduction, we propose that the Hill type muscle model is a crucial parameter for accurately modelling the shoulder. Furthermore, the outcome of this study indicates that the Hill model induces the co-contraction of the muscles of the shoulder without the need of an additional stability criterion for an inverse dynamics approach. KW - Shoulder joint KW - Musculoskeletal modelling KW - EMG KW - Glenohumeral joint reaction force KW - Muscle model KW - Schultergelenk KW - Bewegungsapparat KW - Biomechanik KW - Simulation Y1 - 2020 U6 - https://doi.org/10.1016/j.jbiomech.2020.109817 VL - 106 IS - June PB - Elsevier ER - TY - GEN A1 - Auer, Simon A1 - Reinker, Lukas A1 - Dendorfer, Sebastian T1 - Evaluation of muscle recruitment and muscle models in musculoskeletal simulation of dynamic motion T2 - 26th Congress of the European Society of Biomechanics, July 11-14, 2021, Milan, Italy N2 - Musculoskeletal simulation plays an increasingly important role in sports biomechanics. In the last years, the field of application widened from orthopaedics and ergonomics to sports [1]. A muscle recruitment algorithm with a quadratic objective function is usually used to calculate muscle activity in dynamic movements. The agreement of calculated and measured thigh muscle activity has already been investigated [2]. They found a strong agreement for sprinting and running, while the correlation decreased for side-cutting manoeuvres. Nevertheless, the influence of different muscle recruitment criteria on muscle activity in dynamic musculoskeletal simulations is currently unknown. Hence, this study aimed to analyse the effect of different muscle recruitment criteria and muscle models on the correlation of numerical and measured muscle activity in highly dynamic movements. KW - esb KW - biomechanics KW - muscle recruitment Y1 - 2021 UR - https://esbiomech.org/conference/archive/2021milan/Contribution_1719.pdf CY - Milan ER - TY - JOUR A1 - Reinker, Lukas A1 - Dendorfer, Sebastian T1 - Evaluation of acceleration patterns during high-impact jumping exercises JF - Gait & Posture Y1 - 2023 U6 - https://doi.org/10.1016/j.gaitpost.2022.11.051 VL - 100 IS - Supplement 1, March SP - 93 EP - 94 PB - Elsevier CY - Amsterdam [u.a.] ER - TY - GEN A1 - Förstl, Nikolas A1 - Adler, Ina A1 - Süß, Franz A1 - Jansová, Magdalena A1 - Vychytil, Jan A1 - Dendorfer, Sebastian T1 - Evaluating the loads on the female pelvic floor during full-body activities using computational models N2 - This work investigated the loads on the female pelvic floor during various full-body movements using computational models to calculate abdominal pressure and organ dynamic loads. While high-impact exercises resulted in higher loads, other movements showed lower loads, potentially indicating, which movements may be performed without risking pelvic floor overload and subsequent dysfunctions. Y1 - 2025 ER - TY - GEN A1 - Gschoßmann, Lukas A1 - Schedel, Valentin A1 - Süß, Franz A1 - Weber, Markus A1 - Pfingsten, Andrea A1 - Dendorfer, Sebastian T1 - Evaluating Knee Joint Loads Across Exercises and Activities of Daily Living to Personalize TKA Rehabilitation T2 - ISB 2025 - The XXX Congress of the International Society of Biomechanics, 27.-31. July 2025, Stockholm N2 - This study assessed knee joint loading during various physiotherapy exercises and activities of daily living in 30 healthy subjects. Results showed that lunges and squats caused the highest joint forces, while gait and stair activities also imposed substantial loads. These findings support datadriven exercise selection for personalized rehabilitation after total knee arthroplasty. Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-87252 ER - TY - CHAP A1 - Jungtäubl, Dominik A1 - Aurbach, Maximilian A1 - Melzner, Maximilian A1 - Spicka, Jan A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - EMG-Based Validation of Musculoskeletal Models Considering Crosstalk T2 - International Conference BIOMDLORE, June 28 - 30 2018, Białystok, Poland N2 - BACKGROUND: Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG. OBJECTIVE: This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS: For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets. RESULTS: The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account. CONCLUSIONS: Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough. KW - musculoskeletal modeling KW - validation KW - surface electromyography KW - crosstalk Y1 - 2018 U6 - https://doi.org/10.1109/BIOMDLORE.2018.8467211 ER - TY - CHAP A1 - Aurbach, Maximilian A1 - Jungtäubl, Dominik A1 - Spicka, Jan A1 - Dendorfer, Sebastian T1 - EMG-based validation of musculoskeletal models considering crosstalk T2 - World Congress Biomechanics, 28-30 June 2018, Dublin N2 - BACKGROUND: Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG. OBJECTIVE: This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS: For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets. RESULTS: The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account. CONCLUSIONS: Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough. Y1 - 2018 U6 - https://doi.org/10.1109/BIOMDLORE.2018.8467211 ER - TY - JOUR A1 - Melzner, Maximilian A1 - Engelhardt, Lucas A1 - Simon, Ulrich A1 - Dendorfer, Sebastian T1 - Electromyography-Based Validation of a Musculoskeletal Hand Model JF - Journal of Biomechanical Engineering N2 - Regarding the prevention of injuries and rehabilitation of the human hand, musculoskeletal simulations using an inverse dynamics approach allow for insights of the muscle recruitment and thus acting forces on the hand. Currently, several hand models from various research groups are in use, which are mainly validated by the comparison of numerical and anatomical moment arms. In contrast to this validation and model-building technique by cadaver studies, the aim of this study is to further validate a recently published hand model [1] by analyzing numerically calculated muscle activities in comparison to experimentally measured electromyographical signals of the muscles. Therefore, the electromyographical signals of 10 hand muscles of five test subjects performing seven different hand movements were measured. The kinematics of these tasks were used as input for the hand model, and the numerical muscle activities were computed. To analyze the relationship between simulated and measured activities, the time difference of the muscle on- and off-set points was calculated, which resulted in a mean on- and off-set time difference of 0.58 s between the experimental data and the model. The largest differences were detected for movements that mainly addressed the wrist. One major issue comparing simulated and measured muscle activities of the hand is cross-talk. Nevertheless, the results show that the hand model fits the experiment quite accurately despite some limitations and is a further step toward patient-specific modeling of the upper extremity. KW - Elektromyographie KW - Biomechanik KW - Simulation KW - Electromyography KW - Muscle KW - Musculoskeletal system KW - Signals KW - Simulation Y1 - 2021 U6 - https://doi.org/10.1115/1.4052115 VL - 144 IS - 2 PB - American Society of Mechanical Engineers, ASME ER - TY - CHAP A1 - Dendorfer, Sebastian T1 - Einführung in die Mechanik T2 - Biomechanik Workshop, Klinikum Bad Abbach, Nov. 2013 Y1 - 2013 ER - TY - GEN A1 - Englert, Carsten A1 - Dendorfer, Sebastian T1 - Einfluss der Rotatorenmanschette auf die glenohumerale Stabilität T2 - 20. Intensivkurs Schulterendoprothetik Marburg KW - Biomechanik Y1 - 2022 CY - Marburg ER - TY - CHAP A1 - Englert, Carsten A1 - Müller, F. A1 - Dendorfer, Sebastian T1 - Einfluss der Muskelkräfte, des Bewegungsausmaßes und der Bruchform auf die Kraftübertragung des Implantat-Knochenverbundes am Beispiel der Claviculafraktur im mittleren Drittel T2 - 17. Jahreskongress der Deutschen Vereinigung für Schulter- und Ellenbogenchirurgie (DVSE), Rosenheim 2010 N2 - Fragestellung Es soll in dieser Computersimulationsstudie untersucht werden, wie der Osteosyntheseverbund Platte mit Schrauben im Verbund mit einer im mittleren Drittel gebrochenen Clavicula durch das Bewegungsausmaß in vivo belastet ist. Was sind die grundlegenden Kräfte die auf Clavicula und Implantat wirken und welchen Einfl uss hat die Bruchform. Methodik Die Muskel- und Gelenkkräfte sowie die Belastung des Implantatverbundes wurden mit einer muskuloskelletalen Simulationssoftware (AnyBody Technology, V.4) berechnet. Hierfür wurden mit einem komplexen Model des menschlichen Körpers folgende Bewegungen analysiert: eine Flexion von 160° und Abduktion 160° mit einem Gewicht von 2 kg in der Hand. Aus CT-Patientendaten wurden zwei dreidimensionale Modelle des Clavicula-Implantat Verbundes gebildet, die sich in der Frakturform unterscheiden (Querfraktur und vertikale Fraktur). In beiden Modellen wurde eine Claviculaosteosynthese in superiorer Position mit einer 6 Loch LCP mit 2 Schrauben pro Hauptfragment verwendet. Die Materialeigenschaften wurden aus der Dichte des Materials sowie aus Literaturdaten verwendet. Die Muskel- und Gelenkkräfte aus der muskuloskelletalen Berechnung wurden auf das Finite Elemente Modell übertragen und die Spannungen und Dehnungen des Implantat-Knochenverbundes wurden berechnet. Ergebnisse Es zeigte sich, dass die simulierte in vivo Belastung stark abhängig vom Flexionswinkel ist. Das Implantat ist in der superioren Lage auf Biegung belastet, welche maximale Werte im Überschulterniveau erreicht. Die Bruchform mit anatomischer Reposition und Kontakt der Hauptfragmente zueinander führt zu einer deutlichen Entlastung des Osteosyntheseverbundes im Vergleich zu einer Bruchform mit vertikaler Fraktur. Schlussfolgerung Aus den Analysen ist eine Positionierung der Plattenosteosynthese für die im mittleren Drittel frakturierte Clavicula in anterior-superiorer Lage wünschenswert. Die anatomische Reposition entlastet den Osteosyntheseverbund und sollte möglichst erreicht werden. Die Nachbehandlung sollte ein Bewegungsausmaß für den Arm für 4 Wochen für einfache Bruchformen auf 70° Flexion und Abduktion limitieren und für komplexe Bruchformen diese Limitierung ausgedehnt werden. Y1 - 2010 ER - TY - CHAP A1 - Weber, Tim A1 - Stezowski, P. A1 - Dullien, Silvia A1 - Dendorfer, Sebastian T1 - Eine biomechanische Bewertung verschiedener Belastungsszenarios nach der Implantierung einer Hüft-Totalendoprothese T2 - 89. Jahrestagung der Vereinigung der Bayerischen Chirurgen e.V., 25. - 27. Juli 2012, Regensburg T2 - A biomechanical evaluation of different load scenarios after implantation of a total hip replacement Y1 - 2012 ER - TY - CHAP A1 - Weber, Tim A1 - Stezowski, P. A1 - Dullien, Silvia A1 - Putzer, Michael A1 - Dendorfer, Sebastian T1 - Eine biomechanische Bewertung verschiedener Belastungsszenarien nach Implantierung einer Hüft-Totalendoprothese T2 - GAMMA Workshop, Hannover, 2012 Y1 - 2012 ER - TY - JOUR A1 - Kraus, Richard F. A1 - Knipfer, Maximilian L. A1 - Jacob, Matthias A1 - Kieninger, Baerbel A1 - Alikhani, Jasmine A1 - Ghamsary, Parham Heydarzadeh A1 - Reinker, Lukas A1 - Adler, Ina A1 - Dendorfer, Sebastian A1 - Kieninger, Martin T1 - Effectiveness and safety of techniques for cervical spine immobilization in mountain rescue JF - Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine N2 - BACKGROUND Cervical spine injuries in alpine sports require immediate immobilization at the site of the accident to avoid possible secondary damage caused by transportation. Using special sensor technology, this study investigated whether a cervical spine orthosis (cervical collar, Stifneck collar (Laerdal Medical GmbH, Puchheim, Germany)) provides greater stability than a vacuum mattress alone. METHODS Using one male test person, we simulated transporting a patient with a spinal injury in steep alpine terrain. A wireless motion capture system (Xsens Technologies, Movella™ Inc., Henderson, USA) was used to record motion in three-dimensional space within a standardized environment. All tests were performed on a set course by the Bavarian Mountain Rescue Service. The test person lay on a mountain rescue stretcher and was immobilized with a vacuum mattress, either with or without a cervical orthosis. The axes of cervical spine movements were analyzed separately. RESULTS There were no significant differences between immobilization with and without a cervical orthosis with regard to lateral flexion (max. 3.7° compared to 3.0°) in the frontal plane and maximum excursion in flexion (max. 1.6° compared to 2.8°) or extension (max. -1.6° compared to -1.7°). There was significantly greater rotation movement around the craniocaudal axis without an orthosis (max. 2.4° compared to 1.3°). CONCLUSION During mountain rescues, the cervical spine can be immobilized without a rigid cervical spine orthosis. Future research should explore the fundamental benefits of cervical spine immobilization, while the findings of this work contribute to the safe care of patients by avoiding the disadvantages associated with rigid cervical orthoses. KW - Cervical spine KW - Immobilization KW - Mountain rescue KW - Orthosis KW - Vacuum mattress Y1 - 2026 U6 - https://doi.org/10.1186/s13049-025-01530-z VL - 34 PB - Springer ER - TY - JOUR A1 - Kraus, Richard A1 - Knipfer, Maximilian A1 - Jacob, Matthias A1 - Kienninger, Baerbel A1 - Alikhani, Jasmine A1 - Ghamsary, Parham Heydarzadeh A1 - Reinker, Lukas A1 - Adler, Ina A1 - Dendorfer, Sebastian A1 - Kieninger, Martin T1 - Effectiveness and safety of techniques for cervical spine immobilization in mountain rescue JF - Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine N2 - Background Cervical spine injuries in alpine sports require immediate immobilization at the site of the accident to avoid possible secondary damage caused by transportation. Using special sensor technology, this study investigated whether a cervical spine orthosis (cervical collar, Stifneck collar (Laerdal Medical GmbH, Puchheim, Germany)) provides greater stability than a vacuum mattress alone. Methods Using one male test person, we simulated transporting a patient with a spinal injury in steep alpine terrain. A wireless motion capture system (Xsens Technologies, Movella™ Inc., Henderson, USA) was used to record motion in three-dimensional space within a standardized environment. All tests were performed on a set course by the Bavarian Mountain Rescue Service. The test person lay on a mountain rescue stretcher and was immobilized with a vacuum mattress, either with or without a cervical orthosis. The axes of cervical spine movements were analyzed separately. Results There were no significant differences between immobilization with and without a cervical orthosis with regard to lateral flexion (max. 3.7° compared to 3.0°) in the frontal plane and maximum excursion in flexion (max. 1.6° compared to 2.8°) or extension (max. -1.6° compared to -1.7°). There was significantly greater rotation movement around the craniocaudal axis without an orthosis (max. 2.4° compared to 1.3°). Conclusion During mountain rescues, the cervical spine can be immobilized without a rigid cervical spine orthosis. Future research should explore the fundamental benefits of cervical spine immobilization, while the findings of this work contribute to the safe care of patients by avoiding the disadvantages associated with rigid cervical orthoses. KW - Mountain rescue KW - Orthosis KW - Cervical spine KW - Immobilization KW - Vacuum mattress Y1 - 2026 U6 - https://doi.org/10.1186/s13049-025-01530-z VL - 34 PB - Springer ER - TY - JOUR A1 - Lazarev, Igor A. A1 - Ryabokon, P.V. A1 - Haller, M. A1 - Dendorfer, Sebastian T1 - Effect of the fractured calcaneus's peripheral fragment displacement on the triceps surae function JF - ЖУРНАЛ «ТРАВМА» Ukrainian Trauma Journal Y1 - 2015 VL - 2, TOM 16 ER - TY - JOUR A1 - Lazarev, Igor A. A1 - Riabokon, P. V. A1 - Haller, M. A1 - Dendorfer, Sebastian T1 - Effect of the Displacement of Calcaneal Bone Peripheral Fragment in its Fracture on the Function of the Three-Headed Calf Muscle JF - TRAUMA N2 - In the structure of musculoskeletal injuries, calcaneal fractures account for up to 4 % of all skeletal fractures and up to 60 % of hindfoot fractures. The effect of the displacement of the peripheral fragment of the calcaneus on the calf muscles’s reaction forces at the time of the adoption of the simplified squatting position was investigated by modeling in AnyBody Modeling System 6.0 software. M.gastrocnemius (lateralis et medialis) in the initial phase of motion in all variants of the peripheral fragment displacement did not develop sufficient muscular effort in comparison to the intact calcaneus. M.soleus medialis et lateralis showed significant increase in muscle activity rates in the initial phase of motion (41.87 ± 1.90 H and 52.07 ± 2.10 H) before reaching its maximum values, as compared with those of the intact calcaneus. In the final phase of the movement, upon muscle reaches its maximum length, muscular strength indicators of the m.soleus returned to their original values or were significantly below them. The decline in muscle strength was due to shortening of the moment arm or muscle excursion in case of convergence of muscle attachment points. When the peripheral fragment is displaced, due to putting down the heel to the surface of the support in terms of anatomical muscle lengthening, it takes extra effort to achieve rest length and its maximum power. In all types of the displacement of the peripheral fragment, the function of three-headed calf muscle is disturbed with involvement of additional muscular effort and energy expenditure. This fact should motivate the surgeon on the need for accurate repositioning of bone fragments in calcaneal fractures with the displacement of the peripheral fragment. Y1 - 2016 U6 - https://doi.org/10.22141/1608-1706.2.16.2015.80247 VL - 16 IS - 2 SP - 20 EP - 24 PB - Zaslavsky ER - TY - GEN A1 - Auer, Simon A1 - Krutsch, Werner A1 - Renkawitz, Tobias A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Effect of mental demand on leg loading in highly dynamic motion T2 - AnyBody online Webinar, Oct 2020 N2 - Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury. Y1 - 2020 ER - TY - CHAP A1 - Auer, Simon A1 - Kubowitsch, Simone A1 - Krutsch, Werner A1 - Renkawitz, Tobias A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Effect of mental demand on knee forces in professional youth soccer players T2 - ISBS Proceedings Archive N2 - Soccer is one of the most popular sports all around the world. It is an injurious type of sport with a focus on lower extremities and high psychological pressure during matches. The stressor is linked with injuries and an increased musculoskeletal loading. This study investigates the influence of cognitive stress on the load profile of the knee joint. Twelve professional youth soccer players performed highly dynamic runs with and without additional cognitive stress. The runs were analysed with a musculoskeletal simulation software. The data analysis shows no difference in knee joint reaction loading under additional mental stress compared to the baseline. Yet running times are significantly lower in the baseline. While there is no increase in the joint loads, the running times indicate an altered movement behaviour when the subjects are exposed to additional mental demand. KW - Kniegelenk KW - Körperliche Belastung KW - Stress KW - Computersimulation Y1 - 2020 UR - https://commons.nmu.edu/isbs/vol38/iss1/28 VL - 38 IS - 1, Art. 28 ER - TY - GEN A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Jansen, Petra A1 - Dendorfer, Sebastian T1 - Effect of dual tasking on muscular imbalances T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - JOUR A1 - Weber, Tim A. A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias ED - Takagi, Michiaki T1 - Does Computer-Assisted Femur First THR Improve Musculoskeletal Loading Conditions? JF - BioMed Research International N2 - We have developed a novel, computer-assisted operation method for minimal-invasive total hip replacement (THR) following the concept of “femur first/combined anteversion,” which incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position (CAS FF). The purpose of this study is to assess whether the hip joint reaction forces and patient’s gait parameters are being improved by CAS FF in relation to conventional THR (CON). We enrolled 60 patients (28 CAS FF/32 CON) and invited them for gait analysis at three time points (preoperatively, postop six months, and postop 12 months). Data retrieved from gait analysis was processed using patient-specific musculoskeletal models. The target parameters were hip reaction force magnitude (hrf), symmetries, and orientation with respect to the cup. Hrf in the CAS FF group were closer to a young healthy normal. Phase-shift symmetry showed an increase in the CAS FF group. Hrf orientation in the CAS FF group was closer to optimum, though no edge or rim-loading occurred in the CON group as well. The CAS FF group showed an improved hrf orientation in an early stage and a trend to an improved long-term outcome. KW - Hüftgelenkprothese KW - Operationstechnik KW - Computerunterstütztes Verfahren KW - Bewegungsapparat KW - Mechanische Belastung Y1 - 2015 U6 - https://doi.org/10.1155/2015/625317 VL - 2015 SP - ID 625317 ER - TY - GEN A1 - Dendorfer, Sebastian T1 - Diagnostische Genauigkeit und klinische Anwendungen tragbarer Bewegungssensoren für die Kniegelenksrehabilitation Y1 - 2024 CY - Nürnberg ER - TY - JOUR A1 - Lenich, Andreas A1 - Bachmeier, S. A1 - Dendorfer, Sebastian A1 - Mayr, E. A1 - Nerlich, Michael A1 - Füchtmeier, Bernd T1 - Development of a test system to analyze different hip fracture osteosyntheses under simulated walking JF - Biomedizinische Technik. Biomedical engineering N2 - The mechanical complications of osteosyntheses after hip fractures are previously investigated by mostly static or dynamic uniaxial loading test systems. However, the physiologic loading of the hip joint during a normal gait is a multiplanar, dynamic movement. Therefore, we constructed a system to test osteosyntheses for hip fractures under physiologic multiplanar loading representative of normal gait. To evaluate the testing system, 12 femora pairs were tested under 25,000 cycles with two standard osteosyntheses (Proximal Femoral Nail Antirotation/Gamma3 Nail). For angular movement, the varus collapse to cut out (∝CO) (∝CO=4.8°±2.1° for blade and ∝CO=7.8°±3.8° for screw) was the dominant failure mode, and only slight rotational angle shifts (∝Rot) (∝Rot=1.7°±0.4° for blade and ∝Rot=2.4°±0.3° for screw) of the femoral head around the implant axis were observed. Angular displacements in varus direction and rotation were higher in specimens reinforced with screws. Hence, the cut out model and the migration directions showed a distinction between helical blade and hip screw. However, there were no significant differences between the different implants. The new setup is able to create clinical failures and allows to give evidence about the anchorage stability of different implant types under dynamic gait motion pattern. KW - biomechanical implant test KW - dynamic multiplanar loading KW - hip fractureg KW - implant migration KW - patient specific loading KW - Hüftgelenk KW - Knochenbruch KW - Osteosynthese KW - Bewegungsanalyse KW - Simulation Y1 - 2012 U6 - https://doi.org/10.1515/bmt-2011-0999 VL - 57 IS - 2 SP - 113 EP - 119 ER - TY - CHAP A1 - Putzer, Michael A1 - Weber, Tim A1 - Dendorfer, Sebastian T1 - Design studies on hip prosthesis using patient specific data T2 - Simpleware Users meeting, November 9th 2011, Bristol, UK Y1 - 2011 ER - TY - JOUR A1 - Förstl, Nikolas A1 - Süß, Franz A1 - Englert, Carsten A1 - Dendorfer, Sebastian T1 - Design of a reverse shoulder implant to measure shoulder stiffness during implant component positioning JF - Medical Engineering & Physics N2 - To avoid dislocation of the shoulder joint after reverse total shoulder arthroplasty, it is important to achieve sufficient shoulder stability when placing the implant components during surgery. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this research was to develop a temporary reverse shoulder implant prototype that would allow intraoperative measurement of shoulder stiffness while varying the position of the implant components. Joint angle and torque measurement techniques were developed to determine shoulder stiffness. Hall sensors were used to measure the joint angles by converting the magnetic flux densities into angles. The accuracy of the joint angle measurements was tested using a test bench. Torques were determined by using thin-film pressure sensors. Various mechanical mechanisms for variable positioning of the implant components were integrated into the prototype. The results of the joint angle measurements showed measurement errors of less than 5° in a deflection range of ±15° adduction/abduction combined with ±45° flexion/extension. The proposed design provides a first approach for intra-operative assessment of shoulder stiffness. The findings can be used as a technological basis for further developments. Y1 - 2023 U6 - https://doi.org/10.1016/j.medengphy.2023.104059 N1 - Corresponding author: Sebstian Dendorfer VL - 121 PB - Elsevier ET - Journal Pre-proof ER - TY - GEN A1 - Förstl, Nikolas A1 - Süß, Franz A1 - Englert, Carsten A1 - Dendorfer, Sebastian T1 - Design of a reverse shoulder implant to measure shoulder stiffness during implant component positioning T2 - Book of abstracts / ESB 2023, 28th Congress of the European Society of Biomechanics, 9-12 July 2023, Maastricht, The Netherlands. N2 - Introduction Dislocation of the shoulder joint is one of the more common complications after reverse total shoulder arthroplasty [1], which is often associated with malposition of the prosthetic components [2]. Therefore, achieving sufficient shoulder stability should not be neglected when positioning the implant components. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this work is to develop a reverse shoulder implant prototype that allows intraoperative measurement of shoulder stiffness while varying the position of the implant components. The measured stiffness could provide a quantitative statement regarding the optimal positioning of the implant components, which can be adjusted accordingly in the final reverse shoulder prosthesis. Methods To measure the stiffness of the shoulder joint, it is necessary to record the joint angles and the torques generated during movement. The changes in the rotation angles were measured using 3D hall sensors and magnets. The magnets were placed under the humerosocket, and the hall sensors were integrated into the glenosphere. The strength of the magnetic field was used to determine the position of the humerosocket in relation to the glenosphere. The accuracies of the angle measurements were tested using a test bench. Three thin film pressure sensors were used to record forces at different points under the humerosocket. To obtain a force value from the sensor signal, the sensors were calibrated using a load cell. The variation of the implant components positions was integrated into the prototype implant through different constructive mechanisms to adjust the stiffness of the shoulder joint. Results In the range of ±45° flexion/extension combined with ±15° adduction/abduction, the joint position could be determined with sufficient accuracy (error e ≤ 5°). The areas near the combined maximum deflections of ±45° flexion/extension and ±45° adduction/abduction indicate the greatest deviation from the target angle. The force values of the thin film sensors enable the calculation of moments around two axes. As variable component position parameters, the tray offset, the neck-shaft angle and the humerus version were integrated into the implant prototype. Discussion Ideally, the accuracy of the angle measurements should only depend on the amount of deflection and not on the direction of deflection. The asymmetric behavior indicates a deviation from the correct positioning of the hall sensors. The application of a calibration matrix could compensate for the measurement errors and could demonstrate the potential of the new method for joint angle measurements. The accuracy of the torque measurements and the functionality of the mechanical arresting mechanisms must be investigated in further studies. Overall, the developed measurement method can help to avoid malpositioning of the implant components in reverse total shoulder arthroplasty. References 1. Clark et al, J Shoulder and elbow surgery, 21:36-41 2012. 2. Randelli et al, J Musculoskeletal surgery, 98:15-18, 2014. Y1 - 2023 UR - https://esbiomech.org/conference/archive/2023maastricht/332.pdf ER - TY - CHAP A1 - Hammer, Joachim A1 - Dendorfer, Sebastian T1 - Cyclic loading and microstructure of cancellous bone T2 - Journal of Biomechanics Y1 - 2008 U6 - https://doi.org/10.1016/S0021-9290(08)70409-3 VL - 41 IS - Suppl. 1, July 2008 SP - S410 ER - TY - JOUR A1 - Reinker, Lukas A1 - Bläsing, Dominic A1 - Bierl, Rudolf A1 - Ulbricht, Sabina A1 - Dendorfer, Sebastian T1 - Correlation of Acceleration Curves in Gravitational Direction for Different Body Segments during High-Impact Jumping Exercises JF - sensors N2 - Osteoporosis is a common disease of old age. However, in many cases, it can be very well prevented and counteracted with physical activity, especially high-impact exercises. Wearables have the potential to provide data that can help with continuous monitoring of patients during therapy phases or preventive exercise programs in everyday life. This study aimed to determine the accuracy and reliability of measured acceleration data at different body positions compared to accelerations at the pelvis during different jumping exercises. Accelerations at the hips have been investigated in previous studies with regard to osteoporosis prevention. Data were collected using an IMU-based motion capture system (Xsens) consisting of 17 sensors. Forty-nine subjects were included in this study. The analysis shows the correlation between impacts and the corresponding drop height, which are dependent on the respective exercise. Very high correlations (0.83–0.94) were found between accelerations at the pelvis and the other measured segments at the upper body. The foot sensors provided very weak correlations (0.20–0.27). Accelerations measured at the pelvis during jumping exercises can be tracked very well on the upper body and upper extremities, including locations where smart devices are typically worn, which gives possibilities for remote and continuous monitoring of programs. KW - osteoporosis KW - inertial measurement units KW - wearable motion-tracking sensors KW - high-impact exercisess Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-58217 N1 - Corresponding author: Lukas Reinker N1 - This work was supported by the Bavarian Academic Forum [BayWISS-Verbundkolleg Gesundheit] and the DHZK fond for behavioral cardiovascular diseases [Behaviorale kardiovaskuläre Erkrankungen; grand number: 81Z0400105]. VL - 23 IS - 4 PB - MDPI CY - Basel ER - TY - JOUR A1 - Roldán, J.C. A1 - Moralis, A. A1 - Dendorfer, Sebastian A1 - Witte, J. A1 - Reicheneder, C. T1 - Controlled central advancement of the midface after Le Fort III osteotomy by a 3-point skeletal anchorage JF - The Journal of craniofacial surgery N2 - A 3-point skeletal anchorage with taping screws for distraction osteogenesis after a Le Fort III osteotomy was applied for the first time in a severely mentally impaired patient where intraoral devices had to be avoided. All 3-force application points included the center of resistance, which allowed an optimal control on the resulting moment. A novel device for skeletal long-term retention into the nasal dorsum prevented a relapse, whereas adjustment of the midface position was observed. Fusioned three-dimensional computed tomography analysis revealed real movements not accessible by a conventional cephalometry. KW - Mund-Kiefer-Gesichts-Chirurgie KW - Le Fort III KW - distraction KW - vector KW - anchorage KW - three-dimensional computed tomography analysis KW - Distraktion KW - Knochenbildung KW - Osteotomie KW - Dreidimensionale Bildverarbeitung KW - Computertomografie Y1 - 2011 U6 - https://doi.org/10.1097/SCS.0b013e318231fc8d VL - 22 IS - 6 SP - 2384 EP - 2386 ER - TY - JOUR A1 - De Pieri, Enrico A1 - Atzori, Federica A1 - Ferguson, Stephen J. A1 - Dendorfer, Sebastian A1 - Leunig, Michael A1 - Aepli, Martin T1 - Contact force path in total hip arthroplasty: effect of cup medialisation in a whole-body simulation JF - HIP International N2 - Background: Cup medialisation down to the true acetabular floor in total hip arthroplasty with a compensatory femoral offset increase seems to be mechanically advantageous for the abductor muscles due to the relocation of the lever arms (body weight lever arm decreased, abductor lever arm increased). However, limited information is currently available about the effects of this reconstruction type at the head cup interface, compared to an anatomical reconstruction that maintains the natural lever arms. Through a whole-body simulation analysis, we compared medialised versus anatomical reconstruction in THA to analyse the effects on: (1) contact force magnitude at the head cup interface; (2) contact force path in the cup; and (3) abductor activity. Methods: Musculoskeletal simulations were performed to calculate the above-mentioned parameters using inverse dynamics analysis. The differences between the virtually implanted THAs were calculated to compare the medialised versus anatomical reconstruction. Results: Cup medialisation with compensatory femoral offset increase led to: (1) a reduction in contact force magnitude at the head cup interface up to 6.6%; (2) a similar contact force path in the cup in terms of sliding distance and aspect ratio; and (3) a reduction in abductor activity up to 17.2% (gluteus medius). Conclusions: In our opinion, these potential biomechanical gains do not generally justify a fully medialised reconstruction, especially in younger patients that are more likely to undergo revision surgery in their lifetime. Cup medialisation should be performed until sufficient press fit and bony coverage of a properly sized and oriented cup can be achieved. KW - Cup medialisation KW - femoral offset KW - hip contact force KW - total hip anthroplasty KW - total hip replacement KW - Hüftgelenkprothese KW - Kontaktkraft KW - Biomechanische Analyse KW - Simulation Y1 - 2020 U6 - https://doi.org/10.1177/1120700020917321 VL - 31 IS - 5 SP - 624 EP - 631 PB - Sage ER - TY - JOUR A1 - Englert, Carsten A1 - Angele, Peter A1 - Fierlbeck, J. A1 - Dendorfer, Sebastian A1 - Schubert, T. A1 - Müller, R. A1 - Lienhard, S. A1 - Zellner, Johannes A1 - Nerlich, Michael A1 - Neumann, Carsten T1 - Conductive bone substitute material with variable antibiotic delivery JF - Der Unfallchirurg N2 - A new bone substitute, consisting of hydroxylapatite and calcium sulphate, was prepared in two formulations and analysed for its mechanical strength and antibiotic elution.The bone substitute PerOssal has osteoconductive and degradable properties. The material has a built-in capillary structure, which results in an immediate fluid uptake. Antibiotics absorbed to the bone substitute resulted in a prolonged release rate. Mechanical strength was investigated by an unconfined compression test up to failure under both wet and dry conditions for both formulations of the bone substitute. Antibiotic release was analysed microbiologically for two antibiotics, vancomycin and gentamicin, over an elution period of 10 days using the agar diffusion method.The drug release analysis resulted in a prolonged release rate of both antibiotics over 10 days. In vitro the amount of gentamicin and vancomycin eluted at day 10. From one pellet still exceeded the minimal inhibitory concentration of most aetiologically important pathogens. Formulation two of the present bone substitute is significantly harder in both wet and dry conditions when compared to formulation one. Both formulations lose strength in the wet condition relative to their performance in the dry condition. However, formulation two is as hard under wet conditions as formulation one is when dry.PerOssal is a suitable new degradable osteoconductive bone substitute that can be loaded with antibiotic solutions, which are released in effective doses over 10 days. The mechanical strength of PerOssal is sufficient to support cancellous bone defects in non-weight-bearing areas or in combination with osteosynthesis. KW - Knochenersatz KW - Leitfähgkeit KW - Antibiotika KW - Biomechanik KW - Bone substitute materials KW - Osteoconductive KW - Osteomyelitis KW - Multiresistant KW - Biomechanics Y1 - 2007 U6 - https://doi.org/10.1007/s00113-007-1229-3 VL - 110 IS - 5 SP - 408 EP - 413 PB - Springer ER - TY - CHAP A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Jansen, Petra A1 - Dendorfer, Sebastian T1 - Comparison of dynamic muscular imbalances in back pain patients and healthy controls T2 - World Congress Biomechanics Dublin, 2018 Y1 - 2018 ER -