TY - CHAP A1 - Pilling, A. A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Dendorfer, Sebastian T1 - Experimental workflow for determining psychological stress from physiological biosignals T2 - Jahrestagung der BIOMEDIZINISCHEN TECHNIK und Dreiländertagung der MEDIZINISCHEN PHYSIK, Dresden, Germany, 2017 Y1 - 2017 ER - TY - JOUR A1 - Aurbach, Maximilian A1 - Spicka, Jan A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Evaluation of musculoskeletal modelling parameters of the shoulder complex during humeral abduction above 90° JF - Journal of Biomechanics N2 - Based on electromyographic data and force measurements within the shoulder joint, there is an indication that muscle and resulting joint reaction forces keep increasing over an abduction angle of 90°. In inverse dynamics models, no single parameter could be attributed to simulate this force behaviour accordingly. The aim of this work is to implement kinematic, kinetic and muscle model modifications to an existing model of the shoulder (AnyBody™) and assess their single and combined effects during abduction up to 140° humeral elevation. The kinematics and the EMG activity of 10 test subjects were measured during humeral abduction. Six modifications were implemented in the model: alternative wrapping of the virtual deltoid muscle elements, utilization of a three element Hill model, strength scaling, motion capture driven clavicle elevation/protraction, translation of the GH joint in dependency of the acting forces and an alteration of the scapula/clavicle rhythm. From the six modifications, 16 different combinations were considered. Parameter combinations with the Hill model changed the resultant GH joint reaction force and led to an increase in force during abduction of the humerus above 90°. Under the premise of muscle activities and forces within the GH joint rising after 90° of humeral abduction, we propose that the Hill type muscle model is a crucial parameter for accurately modelling the shoulder. Furthermore, the outcome of this study indicates that the Hill model induces the co-contraction of the muscles of the shoulder without the need of an additional stability criterion for an inverse dynamics approach. KW - Shoulder joint KW - Musculoskeletal modelling KW - EMG KW - Glenohumeral joint reaction force KW - Muscle model KW - Schultergelenk KW - Bewegungsapparat KW - Biomechanik KW - Simulation Y1 - 2020 U6 - https://doi.org/10.1016/j.jbiomech.2020.109817 VL - 106 IS - June PB - Elsevier ER - TY - GEN A1 - Auer, Simon A1 - Reinker, Lukas A1 - Dendorfer, Sebastian T1 - Evaluation of muscle recruitment and muscle models in musculoskeletal simulation of dynamic motion T2 - 26th Congress of the European Society of Biomechanics, July 11-14, 2021, Milan, Italy N2 - Musculoskeletal simulation plays an increasingly important role in sports biomechanics. In the last years, the field of application widened from orthopaedics and ergonomics to sports [1]. A muscle recruitment algorithm with a quadratic objective function is usually used to calculate muscle activity in dynamic movements. The agreement of calculated and measured thigh muscle activity has already been investigated [2]. They found a strong agreement for sprinting and running, while the correlation decreased for side-cutting manoeuvres. Nevertheless, the influence of different muscle recruitment criteria on muscle activity in dynamic musculoskeletal simulations is currently unknown. Hence, this study aimed to analyse the effect of different muscle recruitment criteria and muscle models on the correlation of numerical and measured muscle activity in highly dynamic movements. KW - esb KW - biomechanics KW - muscle recruitment Y1 - 2021 UR - https://esbiomech.org/conference/archive/2021milan/Contribution_1719.pdf CY - Milan ER - TY - JOUR A1 - Reinker, Lukas A1 - Dendorfer, Sebastian T1 - Evaluation of acceleration patterns during high-impact jumping exercises JF - Gait & Posture Y1 - 2023 U6 - https://doi.org/10.1016/j.gaitpost.2022.11.051 VL - 100 IS - Supplement 1, March SP - 93 EP - 94 PB - Elsevier CY - Amsterdam [u.a.] ER - TY - CHAP A1 - Aurbach, Maximilian A1 - Jungtäubl, Dominik A1 - Spicka, Jan A1 - Dendorfer, Sebastian T1 - EMG-based validation of musculoskeletal models considering crosstalk T2 - World Congress Biomechanics, 28-30 June 2018, Dublin N2 - BACKGROUND: Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG. OBJECTIVE: This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS: For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets. RESULTS: The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account. CONCLUSIONS: Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough. Y1 - 2018 U6 - https://doi.org/10.1109/BIOMDLORE.2018.8467211 ER - TY - CHAP A1 - Jungtäubl, Dominik A1 - Aurbach, Maximilian A1 - Melzner, Maximilian A1 - Spicka, Jan A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - EMG-Based Validation of Musculoskeletal Models Considering Crosstalk T2 - International Conference BIOMDLORE, June 28 - 30 2018, Białystok, Poland N2 - BACKGROUND: Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG. OBJECTIVE: This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS: For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets. RESULTS: The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account. CONCLUSIONS: Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough. KW - musculoskeletal modeling KW - validation KW - surface electromyography KW - crosstalk Y1 - 2018 U6 - https://doi.org/10.1109/BIOMDLORE.2018.8467211 ER - TY - JOUR A1 - Melzner, Maximilian A1 - Engelhardt, Lucas A1 - Simon, Ulrich A1 - Dendorfer, Sebastian T1 - Electromyography-Based Validation of a Musculoskeletal Hand Model JF - Journal of Biomechanical Engineering N2 - Regarding the prevention of injuries and rehabilitation of the human hand, musculoskeletal simulations using an inverse dynamics approach allow for insights of the muscle recruitment and thus acting forces on the hand. Currently, several hand models from various research groups are in use, which are mainly validated by the comparison of numerical and anatomical moment arms. In contrast to this validation and model-building technique by cadaver studies, the aim of this study is to further validate a recently published hand model [1] by analyzing numerically calculated muscle activities in comparison to experimentally measured electromyographical signals of the muscles. Therefore, the electromyographical signals of 10 hand muscles of five test subjects performing seven different hand movements were measured. The kinematics of these tasks were used as input for the hand model, and the numerical muscle activities were computed. To analyze the relationship between simulated and measured activities, the time difference of the muscle on- and off-set points was calculated, which resulted in a mean on- and off-set time difference of 0.58 s between the experimental data and the model. The largest differences were detected for movements that mainly addressed the wrist. One major issue comparing simulated and measured muscle activities of the hand is cross-talk. Nevertheless, the results show that the hand model fits the experiment quite accurately despite some limitations and is a further step toward patient-specific modeling of the upper extremity. KW - Elektromyographie KW - Biomechanik KW - Simulation KW - Electromyography KW - Muscle KW - Musculoskeletal system KW - Signals KW - Simulation Y1 - 2021 U6 - https://doi.org/10.1115/1.4052115 VL - 144 IS - 2 PB - American Society of Mechanical Engineers, ASME ER - TY - CHAP A1 - Dendorfer, Sebastian T1 - Einführung in die Mechanik T2 - Biomechanik Workshop, Klinikum Bad Abbach, Nov. 2013 Y1 - 2013 ER - TY - GEN A1 - Englert, Carsten A1 - Dendorfer, Sebastian T1 - Einfluss der Rotatorenmanschette auf die glenohumerale Stabilität T2 - 20. Intensivkurs Schulterendoprothetik Marburg KW - Biomechanik Y1 - 2022 CY - Marburg ER - TY - CHAP A1 - Englert, Carsten A1 - Müller, F. A1 - Dendorfer, Sebastian T1 - Einfluss der Muskelkräfte, des Bewegungsausmaßes und der Bruchform auf die Kraftübertragung des Implantat-Knochenverbundes am Beispiel der Claviculafraktur im mittleren Drittel T2 - 17. Jahreskongress der Deutschen Vereinigung für Schulter- und Ellenbogenchirurgie (DVSE), Rosenheim 2010 N2 - Fragestellung Es soll in dieser Computersimulationsstudie untersucht werden, wie der Osteosyntheseverbund Platte mit Schrauben im Verbund mit einer im mittleren Drittel gebrochenen Clavicula durch das Bewegungsausmaß in vivo belastet ist. Was sind die grundlegenden Kräfte die auf Clavicula und Implantat wirken und welchen Einfl uss hat die Bruchform. Methodik Die Muskel- und Gelenkkräfte sowie die Belastung des Implantatverbundes wurden mit einer muskuloskelletalen Simulationssoftware (AnyBody Technology, V.4) berechnet. Hierfür wurden mit einem komplexen Model des menschlichen Körpers folgende Bewegungen analysiert: eine Flexion von 160° und Abduktion 160° mit einem Gewicht von 2 kg in der Hand. Aus CT-Patientendaten wurden zwei dreidimensionale Modelle des Clavicula-Implantat Verbundes gebildet, die sich in der Frakturform unterscheiden (Querfraktur und vertikale Fraktur). In beiden Modellen wurde eine Claviculaosteosynthese in superiorer Position mit einer 6 Loch LCP mit 2 Schrauben pro Hauptfragment verwendet. Die Materialeigenschaften wurden aus der Dichte des Materials sowie aus Literaturdaten verwendet. Die Muskel- und Gelenkkräfte aus der muskuloskelletalen Berechnung wurden auf das Finite Elemente Modell übertragen und die Spannungen und Dehnungen des Implantat-Knochenverbundes wurden berechnet. Ergebnisse Es zeigte sich, dass die simulierte in vivo Belastung stark abhängig vom Flexionswinkel ist. Das Implantat ist in der superioren Lage auf Biegung belastet, welche maximale Werte im Überschulterniveau erreicht. Die Bruchform mit anatomischer Reposition und Kontakt der Hauptfragmente zueinander führt zu einer deutlichen Entlastung des Osteosyntheseverbundes im Vergleich zu einer Bruchform mit vertikaler Fraktur. Schlussfolgerung Aus den Analysen ist eine Positionierung der Plattenosteosynthese für die im mittleren Drittel frakturierte Clavicula in anterior-superiorer Lage wünschenswert. Die anatomische Reposition entlastet den Osteosyntheseverbund und sollte möglichst erreicht werden. Die Nachbehandlung sollte ein Bewegungsausmaß für den Arm für 4 Wochen für einfache Bruchformen auf 70° Flexion und Abduktion limitieren und für komplexe Bruchformen diese Limitierung ausgedehnt werden. Y1 - 2010 ER - TY - CHAP A1 - Weber, Tim A1 - Stezowski, P. A1 - Dullien, Silvia A1 - Dendorfer, Sebastian T1 - Eine biomechanische Bewertung verschiedener Belastungsszenarios nach der Implantierung einer Hüft-Totalendoprothese T2 - 89. Jahrestagung der Vereinigung der Bayerischen Chirurgen e.V., 25. - 27. Juli 2012, Regensburg T2 - A biomechanical evaluation of different load scenarios after implantation of a total hip replacement Y1 - 2012 ER - TY - CHAP A1 - Weber, Tim A1 - Stezowski, P. A1 - Dullien, Silvia A1 - Putzer, Michael A1 - Dendorfer, Sebastian T1 - Eine biomechanische Bewertung verschiedener Belastungsszenarien nach Implantierung einer Hüft-Totalendoprothese T2 - GAMMA Workshop, Hannover, 2012 Y1 - 2012 ER - TY - JOUR A1 - Lazarev, I.A. A1 - Ryabokon, P.V. A1 - Haller, M. A1 - Dendorfer, Sebastian T1 - Effect of the fractured calcaneus's peripheral fragment displacement on the triceps surae function JF - ЖУРНАЛ «ТРАВМА» Ukrainian Trauma Journal Y1 - 2015 VL - 2, TOM 16 ER - TY - JOUR A1 - Lazarev, I. A. A1 - Riabokon, P. V. A1 - Haller, M. A1 - Dendorfer, Sebastian T1 - Effect of the Displacement of Calcaneal Bone Peripheral Fragment in its Fracture on the Function of the Three-Headed Calf Muscle JF - TRAUMA N2 - In the structure of musculoskeletal injuries, calcaneal fractures account for up to 4 % of all skeletal fractures and up to 60 % of hindfoot fractures. The effect of the displacement of the peripheral fragment of the calcaneus on the calf muscles’s reaction forces at the time of the adoption of the simplified squatting position was investigated by modeling in AnyBody Modeling System 6.0 software. M.gastrocnemius (lateralis et medialis) in the initial phase of motion in all variants of the peripheral fragment displacement did not develop sufficient muscular effort in comparison to the intact calcaneus. M.soleus medialis et lateralis showed significant increase in muscle activity rates in the initial phase of motion (41.87 ± 1.90 H and 52.07 ± 2.10 H) before reaching its maximum values, as compared with those of the intact calcaneus. In the final phase of the movement, upon muscle reaches its maximum length, muscular strength indicators of the m.soleus returned to their original values or were significantly below them. The decline in muscle strength was due to shortening of the moment arm or muscle excursion in case of convergence of muscle attachment points. When the peripheral fragment is displaced, due to putting down the heel to the surface of the support in terms of anatomical muscle lengthening, it takes extra effort to achieve rest length and its maximum power. In all types of the displacement of the peripheral fragment, the function of three-headed calf muscle is disturbed with involvement of additional muscular effort and energy expenditure. This fact should motivate the surgeon on the need for accurate repositioning of bone fragments in calcaneal fractures with the displacement of the peripheral fragment. Y1 - 2016 U6 - https://doi.org/10.22141/1608-1706.2.16.2015.80247 VL - 16 IS - 2 SP - 20 EP - 24 PB - Zaslavsky ER - TY - GEN A1 - Auer, Simon A1 - Krutsch, Werner A1 - Renkawitz, Tobias A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Effect of mental demand on leg loading in highly dynamic motion T2 - AnyBody online Webinar, Oct 2020 N2 - Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury. Y1 - 2020 ER - TY - CHAP A1 - Auer, Simon A1 - Kubowitsch, Simone A1 - Krutsch, Werner A1 - Renkawitz, Tobias A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Effect of mental demand on knee forces in professional youth soccer players T2 - ISBS Proceedings Archive N2 - Soccer is one of the most popular sports all around the world. It is an injurious type of sport with a focus on lower extremities and high psychological pressure during matches. The stressor is linked with injuries and an increased musculoskeletal loading. This study investigates the influence of cognitive stress on the load profile of the knee joint. Twelve professional youth soccer players performed highly dynamic runs with and without additional cognitive stress. The runs were analysed with a musculoskeletal simulation software. The data analysis shows no difference in knee joint reaction loading under additional mental stress compared to the baseline. Yet running times are significantly lower in the baseline. While there is no increase in the joint loads, the running times indicate an altered movement behaviour when the subjects are exposed to additional mental demand. KW - Kniegelenk KW - Körperliche Belastung KW - Stress KW - Computersimulation Y1 - 2020 UR - https://commons.nmu.edu/isbs/vol38/iss1/28 VL - 38 IS - 1, Art. 28 ER - TY - GEN A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Jansen, Petra A1 - Dendorfer, Sebastian T1 - Effect of dual tasking on muscular imbalances T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - JOUR A1 - Weber, Tim A. A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias ED - Takagi, Michiaki T1 - Does Computer-Assisted Femur First THR Improve Musculoskeletal Loading Conditions? JF - BioMed Research International N2 - We have developed a novel, computer-assisted operation method for minimal-invasive total hip replacement (THR) following the concept of “femur first/combined anteversion,” which incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position (CAS FF). The purpose of this study is to assess whether the hip joint reaction forces and patient’s gait parameters are being improved by CAS FF in relation to conventional THR (CON). We enrolled 60 patients (28 CAS FF/32 CON) and invited them for gait analysis at three time points (preoperatively, postop six months, and postop 12 months). Data retrieved from gait analysis was processed using patient-specific musculoskeletal models. The target parameters were hip reaction force magnitude (hrf), symmetries, and orientation with respect to the cup. Hrf in the CAS FF group were closer to a young healthy normal. Phase-shift symmetry showed an increase in the CAS FF group. Hrf orientation in the CAS FF group was closer to optimum, though no edge or rim-loading occurred in the CON group as well. The CAS FF group showed an improved hrf orientation in an early stage and a trend to an improved long-term outcome. KW - Hüftgelenkprothese KW - Operationstechnik KW - Computerunterstütztes Verfahren KW - Bewegungsapparat KW - Mechanische Belastung Y1 - 2015 U6 - https://doi.org/10.1155/2015/625317 VL - 2015 SP - ID 625317 ER - TY - GEN A1 - Dendorfer, Sebastian T1 - Diagnostische Genauigkeit und klinische Anwendungen tragbarer Bewegungssensoren für die Kniegelenksrehabilitation Y1 - 2024 CY - Nürnberg ER - TY - JOUR A1 - Lenich, Andreas A1 - Bachmeier, S. A1 - Dendorfer, Sebastian A1 - Mayr, E. A1 - Nerlich, Michael A1 - Füchtmeier, Bernd T1 - Development of a test system to analyze different hip fracture osteosyntheses under simulated walking JF - Biomedizinische Technik. Biomedical engineering N2 - The mechanical complications of osteosyntheses after hip fractures are previously investigated by mostly static or dynamic uniaxial loading test systems. However, the physiologic loading of the hip joint during a normal gait is a multiplanar, dynamic movement. Therefore, we constructed a system to test osteosyntheses for hip fractures under physiologic multiplanar loading representative of normal gait. To evaluate the testing system, 12 femora pairs were tested under 25,000 cycles with two standard osteosyntheses (Proximal Femoral Nail Antirotation/Gamma3 Nail). For angular movement, the varus collapse to cut out (∝CO) (∝CO=4.8°±2.1° for blade and ∝CO=7.8°±3.8° for screw) was the dominant failure mode, and only slight rotational angle shifts (∝Rot) (∝Rot=1.7°±0.4° for blade and ∝Rot=2.4°±0.3° for screw) of the femoral head around the implant axis were observed. Angular displacements in varus direction and rotation were higher in specimens reinforced with screws. Hence, the cut out model and the migration directions showed a distinction between helical blade and hip screw. However, there were no significant differences between the different implants. The new setup is able to create clinical failures and allows to give evidence about the anchorage stability of different implant types under dynamic gait motion pattern. KW - biomechanical implant test KW - dynamic multiplanar loading KW - hip fractureg KW - implant migration KW - patient specific loading KW - Hüftgelenk KW - Knochenbruch KW - Osteosynthese KW - Bewegungsanalyse KW - Simulation Y1 - 2012 U6 - https://doi.org/10.1515/bmt-2011-0999 VL - 57 IS - 2 SP - 113 EP - 119 ER - TY - CHAP A1 - Putzer, Michael A1 - Weber, Tim A1 - Dendorfer, Sebastian T1 - Design studies on hip prosthesis using patient specific data T2 - Simpleware Users meeting, November 9th 2011, Bristol, UK Y1 - 2011 ER - TY - JOUR A1 - Förstl, Nikolas A1 - Süß, Franz A1 - Englert, Carsten A1 - Dendorfer, Sebastian T1 - Design of a reverse shoulder implant to measure shoulder stiffness during implant component positioning JF - Medical Engineering & Physics N2 - To avoid dislocation of the shoulder joint after reverse total shoulder arthroplasty, it is important to achieve sufficient shoulder stability when placing the implant components during surgery. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this research was to develop a temporary reverse shoulder implant prototype that would allow intraoperative measurement of shoulder stiffness while varying the position of the implant components. Joint angle and torque measurement techniques were developed to determine shoulder stiffness. Hall sensors were used to measure the joint angles by converting the magnetic flux densities into angles. The accuracy of the joint angle measurements was tested using a test bench. Torques were determined by using thin-film pressure sensors. Various mechanical mechanisms for variable positioning of the implant components were integrated into the prototype. The results of the joint angle measurements showed measurement errors of less than 5° in a deflection range of ±15° adduction/abduction combined with ±45° flexion/extension. The proposed design provides a first approach for intra-operative assessment of shoulder stiffness. The findings can be used as a technological basis for further developments. Y1 - 2023 U6 - https://doi.org/10.1016/j.medengphy.2023.104059 N1 - Corresponding author: Sebstian Dendorfer VL - 121 PB - Elsevier ET - Journal Pre-proof ER - TY - CHAP A1 - Hammer, Joachim A1 - Dendorfer, Sebastian T1 - Cyclic loading and microstructure of cancellous bone T2 - Journal of Biomechanics Y1 - 2008 U6 - https://doi.org/10.1016/S0021-9290(08)70409-3 VL - 41 IS - Suppl. 1, July 2008 SP - S410 ER - TY - JOUR A1 - Reinker, Lukas A1 - Bläsing, Dominic A1 - Bierl, Rudolf A1 - Ulbricht, Sabina A1 - Dendorfer, Sebastian T1 - Correlation of Acceleration Curves in Gravitational Direction for Different Body Segments during High-Impact Jumping Exercises JF - sensors N2 - Osteoporosis is a common disease of old age. However, in many cases, it can be very well prevented and counteracted with physical activity, especially high-impact exercises. Wearables have the potential to provide data that can help with continuous monitoring of patients during therapy phases or preventive exercise programs in everyday life. This study aimed to determine the accuracy and reliability of measured acceleration data at different body positions compared to accelerations at the pelvis during different jumping exercises. Accelerations at the hips have been investigated in previous studies with regard to osteoporosis prevention. Data were collected using an IMU-based motion capture system (Xsens) consisting of 17 sensors. Forty-nine subjects were included in this study. The analysis shows the correlation between impacts and the corresponding drop height, which are dependent on the respective exercise. Very high correlations (0.83–0.94) were found between accelerations at the pelvis and the other measured segments at the upper body. The foot sensors provided very weak correlations (0.20–0.27). Accelerations measured at the pelvis during jumping exercises can be tracked very well on the upper body and upper extremities, including locations where smart devices are typically worn, which gives possibilities for remote and continuous monitoring of programs. KW - osteoporosis KW - inertial measurement units KW - wearable motion-tracking sensors KW - high-impact exercisess Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-58217 N1 - Corresponding author: Lukas Reinker N1 - This work was supported by the Bavarian Academic Forum [BayWISS-Verbundkolleg Gesundheit] and the DHZK fond for behavioral cardiovascular diseases [Behaviorale kardiovaskuläre Erkrankungen; grand number: 81Z0400105]. VL - 23 IS - 4 PB - MDPI CY - Basel ER - TY - JOUR A1 - Roldán, J.C. A1 - Moralis, A. A1 - Dendorfer, Sebastian A1 - Witte, J. A1 - Reicheneder, C. T1 - Controlled central advancement of the midface after Le Fort III osteotomy by a 3-point skeletal anchorage JF - The Journal of craniofacial surgery N2 - A 3-point skeletal anchorage with taping screws for distraction osteogenesis after a Le Fort III osteotomy was applied for the first time in a severely mentally impaired patient where intraoral devices had to be avoided. All 3-force application points included the center of resistance, which allowed an optimal control on the resulting moment. A novel device for skeletal long-term retention into the nasal dorsum prevented a relapse, whereas adjustment of the midface position was observed. Fusioned three-dimensional computed tomography analysis revealed real movements not accessible by a conventional cephalometry. KW - Mund-Kiefer-Gesichts-Chirurgie KW - Le Fort III KW - distraction KW - vector KW - anchorage KW - three-dimensional computed tomography analysis KW - Distraktion KW - Knochenbildung KW - Osteotomie KW - Dreidimensionale Bildverarbeitung KW - Computertomografie Y1 - 2011 U6 - https://doi.org/10.1097/SCS.0b013e318231fc8d VL - 22 IS - 6 SP - 2384 EP - 2386 ER - TY - JOUR A1 - De Pieri, Enrico A1 - Atzori, Federica A1 - Ferguson, Stephen J. A1 - Dendorfer, Sebastian A1 - Leunig, Michael A1 - Aepli, Martin T1 - Contact force path in total hip arthroplasty: effect of cup medialisation in a whole-body simulation JF - HIP International N2 - Background: Cup medialisation down to the true acetabular floor in total hip arthroplasty with a compensatory femoral offset increase seems to be mechanically advantageous for the abductor muscles due to the relocation of the lever arms (body weight lever arm decreased, abductor lever arm increased). However, limited information is currently available about the effects of this reconstruction type at the head cup interface, compared to an anatomical reconstruction that maintains the natural lever arms. Through a whole-body simulation analysis, we compared medialised versus anatomical reconstruction in THA to analyse the effects on: (1) contact force magnitude at the head cup interface; (2) contact force path in the cup; and (3) abductor activity. Methods: Musculoskeletal simulations were performed to calculate the above-mentioned parameters using inverse dynamics analysis. The differences between the virtually implanted THAs were calculated to compare the medialised versus anatomical reconstruction. Results: Cup medialisation with compensatory femoral offset increase led to: (1) a reduction in contact force magnitude at the head cup interface up to 6.6%; (2) a similar contact force path in the cup in terms of sliding distance and aspect ratio; and (3) a reduction in abductor activity up to 17.2% (gluteus medius). Conclusions: In our opinion, these potential biomechanical gains do not generally justify a fully medialised reconstruction, especially in younger patients that are more likely to undergo revision surgery in their lifetime. Cup medialisation should be performed until sufficient press fit and bony coverage of a properly sized and oriented cup can be achieved. KW - Cup medialisation KW - femoral offset KW - hip contact force KW - total hip anthroplasty KW - total hip replacement KW - Hüftgelenkprothese KW - Kontaktkraft KW - Biomechanische Analyse KW - Simulation Y1 - 2020 U6 - https://doi.org/10.1177/1120700020917321 VL - 31 IS - 5 SP - 624 EP - 631 PB - Sage ER - TY - JOUR A1 - Englert, Carsten A1 - Angele, Peter A1 - Fierlbeck, J. A1 - Dendorfer, Sebastian A1 - Schubert, T. A1 - Müller, R. A1 - Lienhard, S. A1 - Zellner, J. A1 - Nerlich, Michael A1 - Neumann, Carsten T1 - Conductive bone substitute material with variable antibiotic delivery JF - Der Unfallchirurg N2 - A new bone substitute, consisting of hydroxylapatite and calcium sulphate, was prepared in two formulations and analysed for its mechanical strength and antibiotic elution.The bone substitute PerOssal has osteoconductive and degradable properties. The material has a built-in capillary structure, which results in an immediate fluid uptake. Antibiotics absorbed to the bone substitute resulted in a prolonged release rate. Mechanical strength was investigated by an unconfined compression test up to failure under both wet and dry conditions for both formulations of the bone substitute. Antibiotic release was analysed microbiologically for two antibiotics, vancomycin and gentamicin, over an elution period of 10 days using the agar diffusion method.The drug release analysis resulted in a prolonged release rate of both antibiotics over 10 days. In vitro the amount of gentamicin and vancomycin eluted at day 10. From one pellet still exceeded the minimal inhibitory concentration of most aetiologically important pathogens. Formulation two of the present bone substitute is significantly harder in both wet and dry conditions when compared to formulation one. Both formulations lose strength in the wet condition relative to their performance in the dry condition. However, formulation two is as hard under wet conditions as formulation one is when dry.PerOssal is a suitable new degradable osteoconductive bone substitute that can be loaded with antibiotic solutions, which are released in effective doses over 10 days. The mechanical strength of PerOssal is sufficient to support cancellous bone defects in non-weight-bearing areas or in combination with osteosynthesis. KW - Knochenersatz KW - Leitfähgkeit KW - Antibiotika KW - Biomechanik KW - Bone substitute materials KW - Osteoconductive KW - Osteomyelitis KW - Multiresistant KW - Biomechanics Y1 - 2007 U6 - https://doi.org/10.1007/s00113-007-1229-3 VL - 110 IS - 5 SP - 408 EP - 413 PB - Springer ER - TY - CHAP A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Jansen, Petra A1 - Dendorfer, Sebastian T1 - Comparison of dynamic muscular imbalances in back pain patients and healthy controls T2 - World Congress Biomechanics Dublin, 2018 Y1 - 2018 ER - TY - JOUR A1 - Morag, Sarah A1 - Kieninger, Martin A1 - Eissnert, Christoph A1 - Auer, Simon A1 - Dendorfer, Sebastian A1 - Popp, Daniel A1 - Hoffmann, Johannes A1 - Kieninger, Bärbel T1 - Comparison of different techniques for prehospital cervical spine immobilization: Biomechanical measurements with a wireless motion capture system JF - PLOS ONE Y1 - 2023 U6 - https://doi.org/10.1371/journal.pone.0292300 VL - 18 IS - 11 SP - 1 EP - 14 PB - PLOS CY - San Francisco, California ER - TY - GEN A1 - Auer, Simon A1 - Reinker, Lukas A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Comparing calculated and measured muscle activity of thigh muscles in dynamic motion. T2 - 27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal Y1 - 2022 UR - https://drive.google.com/uc?id=1RBguxyHZE-Wr2y6ktOWK06_3lQg2M9Rb&export=download&confirm=t SP - 640 ER - TY - CHAP A1 - Gross, Simon A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - Combined Experimental and Numerical Approach to Investigate Changes in Muscle Recruitment Pattern of the Back Muscles during Exhausting Exercise T2 - World Congress Biomechanics Dublin, 2018 N2 - In recent years, musculoskeletal computation has become a widely used tool to investigate joint and muscle forces within the human body. However, the issue of muscle fatigue is not considered adequately in most models and is a challenging task. One aspect that needs to be examined is the interaction of muscles during an exhausting task. Therefore, an experimental study was designed to analyze the changes of back muscle recruitment pattern during such exercises. In this study 38 subjects (27 male, 11 female, height = 177±8.5 cm, weight = 74.0±13.6 kg) participated. Each subject had to perform three static and three dynamic exhausting exercises where the back muscles were loaded with subject specific forces using a dynamometer adapter especially designed for the trunk muscles. To collect the muscle activity, twelve surface electromyography sensors were applied on the back, and four on the abdominal muscles. Muscle activity and fatigue were analyzed by calculating the maximum voluntary contraction normalized signal and the median frequency. At first the fatigue of m. erector spinae and m. multifidi was analyzed, since these muscles carry the main load during the exercises. Subsequently the activity of the m. trapezius, m. rectus abdominis and m. obliquus externus were investigated to determine recruitment patterns. To gain more detailed information of these patterns a numerical model was built using the AnyBody Modeling System™. Analyzing the measurements, we can observe an increasing muscle activity during isokinetic exercises while the force is constant. Since the activity in the simulation is defined as the current force output divided by the strength of the muscle, the strength parameter was scaled down based on the measured data, assuming a linear force – activity correlation, and using a numerical algorithm considering the influence of cross talk. The results show, that changes in recruitment pattern can be divided into three major subgroups. Prior to total exhaustion, some of the subjects show additional activation of muscles in the trapezius region, while other subjects show an additional activation of abdominal muscles, increasing the intra-abdominal pressure which supports the spine. In the third group an activation in both regions can be observed. The numerical simulations show an increasing activity of abdominal muscles as well as muscles in the upper back. Especially the m. latissimus dorsi shows a significantly higher activity. The results lead to the conclusion that prior to total exhaustion, additional muscles are recruited to support the main muscles. It was shown that abdominal muscles are activated to support back muscles by pressurizing the trunk cavity to delay total exhaustion as long as possible. In conclusion, the results show that changes in muscle recruitment pattern need to be considered when introducing muscle fatigue to musculoskeletal models. Y1 - 2018 ER - TY - GEN A1 - Auer, Simon A1 - Niebler, Michael A1 - Eiglsperger, Josef A1 - Kubowitsch, Simone A1 - Renkawitz, Tobias A1 - Achenbach, Leonard A1 - Krutsch, Werner A1 - Dendorfer, Sebastian T1 - Cognitive stress increases muscle forces in dynamic football specific movements T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - CHAP A1 - Dendorfer, Sebastian A1 - Feldotto, Benedikt A1 - Walch, Blasius A1 - Koch, Patrick A1 - Knoll, Alois T1 - Co-Development of an Infant Prototype in Hardware and Simulation based on CT Imaging Data T2 - IEEE International Conference on Cyborg and Bionic Systems (CBS), 2019, Munich N2 - The development of biomimetic robots has gained research interest in the last years as it may both help under-standing processes of motion execution in biological systems as well as developping a novel generation of intelligent and energy efficient robots. However, exact model generation that builds up on observations and robot design is very time intensive. In this paper we present a novel pipeline for co-development of biomimetic hardware and simulation models based on biological Computer Tomography (CT) data. For this purpose we exploit State of the Art rapid prototyping technologies such as 3D Printing and the Neurorobotics Platform for musculoskeletal simulations in virtual environments. The co-development integrates both advantages of virtual and physical experimental models and is expected to increase development speed of controllers that can be tested on the simulated counterpart before application to a printed robot model. We demonstrate the pipeline by generating a one year old infant model as a musculoskeletal simulation model and a print-in-place 3D printed skeleton as a single movable part. Even though we hereonly introduce the initial body generation and only a first testsetup for a modular sensory and control framework, we can clearly spot advantages in terms of rapid model generation and highly biological related models. Engineering costs are reducedand models can be provided to a wide research community for controller testing in an early development phase. KW - Biomechanische Analyse KW - Robotik KW - Computertomographie KW - 3D-Druck Y1 - 2019 UR - http://mediatum.ub.tum.de/doc/1520042/985669104579.pdf ER - TY - CHAP A1 - Weber, Tim A1 - Dendorfer, Sebastian A1 - Renkawitz, Tobias A1 - Dullien, Silvia A1 - Grifka, Joachim T1 - Clinical gait analysis combined with musculoskeletal modelling – coding a new generation of evaluation instruments T2 - Deutsche Gesellschaft für Biomechanik, Murnau, 2011 Y1 - 2011 ER - TY - JOUR A1 - Dendorfer, Sebastian A1 - Hammer, Joachim A1 - Lenich, Andreas T1 - Characterisation and testing of biomaterials JF - Technology and Health Care KW - Testing biomaterials KW - Characterisation testing KW - Biomaterial KW - Test Y1 - 2011 U6 - https://doi.org/10.3233/THC-2011-0644 VL - 19 IS - 5 SP - 357 EP - 371 ER - TY - CHAP A1 - Dendorfer, Sebastian A1 - Hammer, Joachim A1 - Lenich, Andreas ED - Lee, T. Clive ED - Niederer, Peter F. T1 - Characterisation and testing of biomaterials T2 - Basic Engineering for Medics and Biologists: An ESEM Primer KW - Biomaterial KW - Werkstoff KW - Test Y1 - 2010 SN - 978-1607505266 IS - Chapter IV.4. PB - Non Basic Stock Line ER - TY - JOUR A1 - Pfeifer, Christian A1 - Müller, Michael A1 - Prantl, Lukas A1 - Berner, Arne A1 - Dendorfer, Sebastian A1 - Englert, Carsten T1 - Cartilage labelling for mechanical testing in T-peel configuration JF - International Orthopaedics N2 - PURPOSE: The purpose of this study was to find a suitable method of labelling cartilage samples for the measurement of distraction distances in biomechanical testing. METHODS: Samples of bovine cartilage were labelled using five different methods: hydroquinone and silver nitrate (AgNO3), potassium permanganate (KMnO4) with sodium thiosulphate (Na2S2O3), India ink, heat, and laser energy. After the labelling, we analysed the cartilage samples with regard to cytotoxity by histochemical staining with ethidiumbromide homodimer (EthD-1) and calcein AM. Furthermore, we tested cartilages labelled with India ink and heat in a T-peel test configuration to analyse possible changes in the mechanical behaviour between marked and unlabelled samples. RESULTS: Only the labelling methods with Indian ink or a heated needle showed acceptable results in the cytotoxity test with regard to labelling persistence, accuracy, and the influence on consistency and viability of the chondrocytes. In the biomechanical T-peel configuration, heat-labelled samples collapsed significantly earlier than unlabelled samples. CONCLUSION: Labelling bovine cartilage samples with Indian ink in biomechanical testing is a reliable, accurate, inexpensive, and easy-to-perform method. This labelling method influenced neither the biomechanical behaviour nor the viability of the tissue compared to untreated bovine cartilage. KW - Bovine cartilage KW - Cartilage samples KW - Indian ink KW - T-peel configuration KW - Method labeling KW - Knorpel KW - Rind KW - Kennzeichnung KW - Tinte KW - Biomechanik KW - Prüfung Y1 - 2012 U6 - https://doi.org/10.1007/s00264-011-1468-3 VL - 36 IS - 7 SP - 1493 EP - 1499 PB - Springer ER - TY - GEN A1 - Dendorfer, Sebastian T1 - Biomechanische Aspekte bei Sportverletzungen T2 - OT World Leipzig, Internationale Fachmesse und Weltkongress für Orthopädie und Rehatechnik, 10.-13. Mai 2022 Y1 - 2022 ER - TY - GEN A1 - Melzner, Maximilian A1 - Dendorfer, Sebastian T1 - Biomechanik und muskuloskeletale Simulation T2 - Jahreskongress des ISPO Deutschland e.V., 2./3. Juni 2022, Hedelberg Y1 - 2022 ER - TY - CHAP A1 - Dendorfer, Sebastian T1 - Biomechanik des Alterns T2 - Kolpingfortbildung Lambach, April 2016 Y1 - 2016 ER - TY - CHAP A1 - Weber, Tim A1 - Renkawitz, Tobias A1 - Bulstra, Sjoerd K. A1 - Grifka, Joachim A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - Biomechanics of computer-assisted vs. conventional THR after one year follow up T2 - XXV Congress of the International Society of Biomechanics, Glasgow, UK, 12th-16th July 2015 Y1 - 2015 ER - TY - CHAP A1 - Weber, Tim A1 - Dullien, Silvia A1 - Putzer, Michael A1 - Dendorfer, Sebastian A1 - Renkawitz, Tobias T1 - Biomechanical outcome after computer-assisted vs. conventional THR – study concept and preliminary gait analysis results T2 - GAMMA Workshop, Hannover, 2012 Y1 - 2012 ER - TY - CHAP A1 - Weber, Tim A1 - Dendorfer, Sebastian A1 - Bulstra, Sjoerd K. A1 - Verkerke, Gijsbertus Jacob A1 - Renkawitz, Tobias T1 - Biomechanical Outcome after computer-assisted vs. Conventional THR T2 - ANSYS Conference & 32th CADFEM Users' Meeting 2014, 04.-06. Juni, Nürnberg Y1 - 2014 UR - https://www.researchgate.net/publication/264547774_Biomechanical_outcome_after_computer-assisted_vs_conventional_THR ER - TY - CHAP A1 - Dendorfer, Sebastian T1 - Biomechanical evaluation and optimisation of countermeasure exercises T2 - ESA/ESTEC Bedrest Strategy Workshop, Noordwijk, NL, 2009 Y1 - 2009 ER - TY - CHAP A1 - Penzkofer, Rainer A1 - Grechenig, S. A1 - Kujat, Richard A1 - Angele, Peter A1 - Dendorfer, Sebastian T1 - Biomechanical comparison of the dorsal femur condyles and the iliac crest in terms of failure behavior T2 - XXV Congress of the International Society of Biomechanics, Glasgow, UK, 12th-16th July 2015 Y1 - 2015 ER - TY - JOUR A1 - Auer, Simon A1 - Schiebl, Jonas A1 - Iversen, Kristoffer A1 - Subhash Chander, Divyaksh A1 - Damsgaard, Michael A1 - Dendorfer, Sebastian T1 - Biomechanical assessment of the design and efficiency of occupational exoskeletons with the AnyBody Modeling System JF - Zeitschrift für Arbeitswissenschaften N2 - Exoskeletons were invented over 100 years ago but have only become popular in the last two decades, especially in the working industry as they can decrease work-related loads significantly. The most often used exoskeletons are for the lower back and shoulder since these are commonly affected body regions. All devices have in common that their purpose is to reduce internal loads of vulnerable body regions. Nevertheless, there is still little understanding on how biomechanical loading in the human body changes when exoskeletons are used. Therefore, further analyses are needed. A promising candidate for these are musculoskeletal models, which are based on an inverse dynamics approach and can calculate external parameters such as ground reaction forces or other interaction forces as well as internal parameters such as joint reaction forces or muscle activities. The various examples in the literature show that these models are increasingly used for assessing the biomechanical effects of exoskeletons on the human body. Furthermore, musculoskeletal models can calculate biomechanical loadings of humans with and without exoskeletons for all kinds of applications and allow an evaluation of their purpose. Practical Relevance: This article highlights the possibilities of musculoskeletal models for assessing the design and efficiency of occupational exoskeletons. Several practical use cases are described along with distinct descriptions of common implications of musculoskeletal and exoskeleton modeling. KW - Biomechanics KW - Ergonomics KW - Motion capture KW - Inverse dynamics Y1 - 2022 U6 - https://doi.org/10.1007/s41449-022-00336-4 N1 - Corresponding author: Sebastian Dendorfer VL - 76 IS - 4 SP - 440 EP - 449 PB - Springer Nature ER - TY - GEN A1 - Saffert, Anne-Sophia A1 - Melzner, Maximilian A1 - Dendorfer, Sebastian T1 - Biomechanical Analysis of the Right Elevated Glenohumeral Joint in Violinists during Legato-Playing T2 - Biomdlore 2021: 21-23 October 2021 Vilnius/Trakai, Lithuania N2 - BACKGROUND: Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements. OBJECTIVE: For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture. METHODS: Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position. RESULTS: The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture. CONCLUSIONS: Elevating the right shoulder while playing the violin may pose a potential problem. Y1 - 2021 U6 - https://doi.org/10.3233/THC-219001 N1 - Veröffentlicht in: Technology and Health Care, vol. 30, no. 1 (Selected Papers From the 13th International Conference BIOMDLORE 2021), pp. 177-186, 2022 ER - TY - JOUR A1 - Saffert, Anne-Sophie A1 - Melzner, Maximilian A1 - Dendorfer, Sebastian T1 - Biomechanical analysis of the right elevated glenohumeral joint in violinists during legato-playing JF - Technology and Health Care N2 - BACKGROUND: Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements. OBJECTIVE: For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture. METHODS: Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position. RESULTS: The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture. CONCLUSIONS: Elevating the right shoulder while playing the violin may pose a potential problem. KW - Biomechanische Analyse KW - Schultergelenk KW - Verletzung KW - Violinspiel KW - biomechanics KW - violin KW - shoulder elevation KW - shoulder joint force KW - musculoskeletal disease Y1 - 2022 U6 - https://doi.org/10.3233/THC-219001 N1 - Corresponding author: Anne-Sophie Saffert VL - 30 IS - 1 SP - 177 EP - 186 PB - IOS Press ER - TY - JOUR A1 - Schmitz, Paul A1 - Neumann, Christoph Cornelius A1 - Neumann, Carsten A1 - Nerlich, Michael A1 - Dendorfer, Sebastian T1 - Biomechanical analysis of iliac crest loading following cortico-cancellous bone harvesting JF - Journal of Orthopaedic Surgery and Research N2 - Background Iliac crest bone harvesting is a frequently performed surgical procedure widely used to treat bone defects. The objective of this study is to assess the biomechanical quantities related to risk for pelvic fracture after harvesting an autologous bone graft at the anterior iliac crest. Methods Finite element models with a simulated harvest site (sized 15 × 20 mm, 15 × 35 mm, 30 × 20 mm and 30 × 35 mm) in the iliac wing are created. The relevant loading case is when the ipsilateral leg is lifted off the ground. Musculoskeletal analysis is utilized to compute the muscle and joint forces involved in this motion. These forces are used as boundary conditions for the finite element analyses. Bone tissue stress is analyzed. Results Critical stress peaks are located between the anterior superior iliac spine (ASIS) and the anterior edge of the harvest site. Irrespective of the graft size, the iliac wing does not show any significant stress peaks with the harvest site being 20 to 25 mm posterior to the ASIS. The harvest area itself inhibits the distribution of the forces applied on the ASIS to extend to the posterior iliac wing. This leads to a lack of stress posterior to the harvest site. A balanced stress distribution with no stress peaks appears when the bone graft is taken below the iliac crest. Conclusion A harvest site located at least 20 to 25 mm posterior to the ASIS should be preferred to minimize the risk of iliac fatigue fracture. KW - Bone harvesting KW - Autologous bone graft KW - Iliac crest KW - Fatigue fracture KW - Pelvis KW - ASIS KW - FEA KW - Biomechanical investigation KW - Beckenkammknochen KW - Knochenentnahme KW - Spongiosa KW - Biomechanische Analyse Y1 - 2018 U6 - https://doi.org/10.1186/s13018-018-0822-1 VL - 13 IS - 108 SP - 1 EP - 8 PB - Springer Nature ER - TY - CHAP A1 - Robie, Bruce A1 - Dendorfer, Sebastian A1 - Rasmussen, John A1 - Christensen, Soeren Toerholm T1 - Axial Rotation Requires Greatest Load in Multifidus Muscle – Potential Association with Low Back Pain? T2 - Annual Meeting of the AANS/CNS Section on Disorders of the Spine and Peripheral Nerves, 2011, Phoenix, Arizona Y1 - 2011 UR - https://paperpile.com/shared/o0LQEG ER -