TY - GEN A1 - Auer, Simon A1 - Reinker, Lukas A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Comparing calculated and measured muscle activity of thigh muscles in dynamic motion. T2 - 27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal Y1 - 2022 UR - https://drive.google.com/uc?id=1RBguxyHZE-Wr2y6ktOWK06_3lQg2M9Rb&export=download&confirm=t SP - 640 ER - TY - GEN A1 - Melzner, Maximilian A1 - Pfeifer, Christian A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Muskuloskeletal analysis of elbow stability for common injury patterns T2 - 27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal Y1 - 2022 UR - https://drive.google.com/uc?id=1RBguxyHZE-Wr2y6ktOWK06_3lQg2M9Rb&export=download&confirm=t SP - 654 ER - TY - GEN A1 - Eger, Maximilian A1 - Bergstraesser, Marcel A1 - Dendorfer, Sebastian A1 - Lenich, Andreas A1 - Pfeifer, Christian T1 - Influence of radial head prosthetic design on humeroradial stability: Validation of a test rig therefore T2 - DOKU2022, Deutscher Kongress für Orthopädie und Unfallchirurgie, 25.-28. 10.2022, Berlin KW - radial head prostheses KW - humeroradial stability KW - radial head arthroplasty KW - subluxation Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0183-22dkou6115 PB - German Medical Science GMS Publishing House CY - Düsseldorf ER - TY - GEN A1 - Kögler, Michael A1 - Ismail, Khaled M. A1 - Rusavy, Zdenek A1 - Kalis, Vladimir A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Influence of bed height and stance on accoucheurs lower back and glenohumeral load during simulated childbirth T2 - 31st meeting of Czech Urogynaecological Society, Prague, 2022 Y1 - 2022 ER - TY - GEN A1 - Melzner, Maximilian A1 - Engelhardt, Leonard A1 - Süß, Friedrich A1 - Dendorfer, Sebastian T1 - Sensitivity evaluation of a musculoskeletal hand model using Latin hypercube sampling T2 - ESMAC 2020 Abstracts Y1 - 2020 U6 - https://doi.org/10.1016/j.gaitpost.2020.08.008 VL - 81 IS - Suppl. 1 PB - Elsevier ER - TY - GEN A1 - Engelhardt, Lucas A1 - Melzner, Maximilian A1 - Havelkova, Linda A1 - Fiala, Pavel A1 - Rybarova, Martina A1 - Christen, Patrik A1 - Dendorfer, Sebastian A1 - Simon, Ulrich T1 - A new musculoskeletal AnyBody detailed hand model T2 - European Society of Biomechanics meeting 2019, Vienna, Austria N2 - The AnyBody™ Modeling System (AMS) [1], is an universally used musculoskeletal simulation software using inverse dynamics. Until now, no complete human hand model is known in the AMS. Also considering other musculoskeletal software platforms, just one detailed entire hand model is recently published [2] but is only based on one subject. The aim of this work is to implement a full detailed hand model for the AMS including all extrinsic and intrinsic muscles using data by the UWB gained through an anatomical study of ten cadaver hands. Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - GEN A1 - Auer, Simon A1 - Niebler, Michael A1 - Eiglsperger, Josef A1 - Kubowitsch, Simone A1 - Renkawitz, Tobias A1 - Achenbach, Leonard A1 - Krutsch, Werner A1 - Dendorfer, Sebastian T1 - Cognitive stress increases muscle forces in dynamic football specific movements T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - GEN A1 - Aurbach, Maximilian A1 - Spicka, Jan A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Musculoskeletal modelling of the shoulder – effects on muscle recruitment and joint reaction force T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - GEN A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Jansen, Petra A1 - Dendorfer, Sebastian T1 - Effect of dual tasking on muscular imbalances T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - GEN A1 - Auer, Simon A1 - Reinker, Lukas A1 - Dendorfer, Sebastian T1 - Evaluation of muscle recruitment and muscle models in musculoskeletal simulation of dynamic motion T2 - 26th Congress of the European Society of Biomechanics, July 11-14, 2021, Milan, Italy N2 - Musculoskeletal simulation plays an increasingly important role in sports biomechanics. In the last years, the field of application widened from orthopaedics and ergonomics to sports [1]. A muscle recruitment algorithm with a quadratic objective function is usually used to calculate muscle activity in dynamic movements. The agreement of calculated and measured thigh muscle activity has already been investigated [2]. They found a strong agreement for sprinting and running, while the correlation decreased for side-cutting manoeuvres. Nevertheless, the influence of different muscle recruitment criteria on muscle activity in dynamic musculoskeletal simulations is currently unknown. Hence, this study aimed to analyse the effect of different muscle recruitment criteria and muscle models on the correlation of numerical and measured muscle activity in highly dynamic movements. KW - esb KW - biomechanics KW - muscle recruitment Y1 - 2021 UR - https://esbiomech.org/conference/archive/2021milan/Contribution_1719.pdf CY - Milan ER - TY - GEN A1 - Förstl, Nikolas A1 - Süß, Franz A1 - Englert, Carsten A1 - Dendorfer, Sebastian T1 - Design of a reverse shoulder implant to measure shoulder stiffness during implant component positioning T2 - Book of abstracts / ESB 2023, 28th Congress of the European Society of Biomechanics, 9-12 July 2023, Maastricht, The Netherlands. N2 - Introduction Dislocation of the shoulder joint is one of the more common complications after reverse total shoulder arthroplasty [1], which is often associated with malposition of the prosthetic components [2]. Therefore, achieving sufficient shoulder stability should not be neglected when positioning the implant components. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this work is to develop a reverse shoulder implant prototype that allows intraoperative measurement of shoulder stiffness while varying the position of the implant components. The measured stiffness could provide a quantitative statement regarding the optimal positioning of the implant components, which can be adjusted accordingly in the final reverse shoulder prosthesis. Methods To measure the stiffness of the shoulder joint, it is necessary to record the joint angles and the torques generated during movement. The changes in the rotation angles were measured using 3D hall sensors and magnets. The magnets were placed under the humerosocket, and the hall sensors were integrated into the glenosphere. The strength of the magnetic field was used to determine the position of the humerosocket in relation to the glenosphere. The accuracies of the angle measurements were tested using a test bench. Three thin film pressure sensors were used to record forces at different points under the humerosocket. To obtain a force value from the sensor signal, the sensors were calibrated using a load cell. The variation of the implant components positions was integrated into the prototype implant through different constructive mechanisms to adjust the stiffness of the shoulder joint. Results In the range of ±45° flexion/extension combined with ±15° adduction/abduction, the joint position could be determined with sufficient accuracy (error e ≤ 5°). The areas near the combined maximum deflections of ±45° flexion/extension and ±45° adduction/abduction indicate the greatest deviation from the target angle. The force values of the thin film sensors enable the calculation of moments around two axes. As variable component position parameters, the tray offset, the neck-shaft angle and the humerus version were integrated into the implant prototype. Discussion Ideally, the accuracy of the angle measurements should only depend on the amount of deflection and not on the direction of deflection. The asymmetric behavior indicates a deviation from the correct positioning of the hall sensors. The application of a calibration matrix could compensate for the measurement errors and could demonstrate the potential of the new method for joint angle measurements. The accuracy of the torque measurements and the functionality of the mechanical arresting mechanisms must be investigated in further studies. Overall, the developed measurement method can help to avoid malpositioning of the implant components in reverse total shoulder arthroplasty. References 1. Clark et al, J Shoulder and elbow surgery, 21:36-41 2012. 2. Randelli et al, J Musculoskeletal surgery, 98:15-18, 2014. Y1 - 2023 UR - https://esbiomech.org/conference/archive/2023maastricht/332.pdf ER - TY - GEN A1 - Melzner, Maximilian A1 - Ismail, Khaled M. A1 - Rušavý, Zdeněk A1 - Kališ, Vladimír A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Musculoskeletal Lower Back Load of Accoucheurs During Delivery T2 - 26th Congress of the European Society of Biomechanics, July 11-14, 2021, Milan, Italy N2 - With the progress in modern medicine, it was possible to significantly reduce the risks of birth for mother and child. One aspect that has received less attention so far is the risk of injury to the accoucheurs (obstetricians and midwives) during the birth process. Indeed, studies indicate that 92% of midwives suffer from musculoskeletal disorders, with the lower back being the main cause of complaints (72%). The aim of this study was to investigate two commonly used postural techniques used by accoucheurs during childbirth and to analyze the resulting load on the lower back using the AnyBodyTM musculoskeletal simulation software. Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-20208 CY - Milan ER - TY - GEN A1 - Gschoßmann, Lukas A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Impact of Model Parameters on Ground Reaction Force Predictions in Musculoskeletal Modelling T2 - ISB 2025 - The XXX Congress of the International Society of Biomechanics, 27-31 July, Stockholm N2 - This study evaluated how model parameters affect ground reaction force (GRF) predictions in musculoskeletal simulations. A parameter study varying contact height and velocity thresholds and marker weights was conducted. While height and velocity thresholds had minimal impact, marker weights impact prediction errors. These findings highlight the importance of carefully selecting model parameters. Y1 - 2025 ER - TY - GEN A1 - Adler, Ina A1 - Förstl, Nikolas A1 - Čechová, Hana A1 - Nováček, Vít A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Mechanistic analysis of pelvic floor functionality using musculoskeletal simulation T2 - ISB 2025 - The XXX Congress of the International Society of Biomechanics, 27-31 July 2025, Stockholm N2 - There is consensus that knowledge about the fundamentals of the pelvic floor remains incomplete, particularly regarding the sensitivity of individual pelvic floor muscles to posture variations. This study aimed to investigate the effects of variations in pelvic tilt and the point of force application induced by changes in posture on pelvic floor activity using musculoskeletal simulation. A parameter study analysed various loading cases, highlighting the coherent response of individual pelvic floor muscles to loads. Muscle activities and forces were compared across different force application points and pelvic tilt angles. A key finding was identifying peak muscle activity conditions that could help better understand the causes of pelvic floor disorders. Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-87294 ER - TY - GEN A1 - Gschoßmann, Lukas A1 - Schedel, Valentin A1 - Süß, Franz A1 - Weber, Markus A1 - Pfingsten, Andrea A1 - Dendorfer, Sebastian T1 - Evaluating Knee Joint Loads Across Exercises and Activities of Daily Living to Personalize TKA Rehabilitation T2 - ISB 2025 - The XXX Congress of the International Society of Biomechanics, 27.-31. July 2025, Stockholm N2 - This study assessed knee joint loading during various physiotherapy exercises and activities of daily living in 30 healthy subjects. Results showed that lunges and squats caused the highest joint forces, while gait and stair activities also imposed substantial loads. These findings support datadriven exercise selection for personalized rehabilitation after total knee arthroplasty. Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-87252 ER -