TY - CHAP A1 - Putzer, Michael A1 - Galibarov, Pavel E. A1 - Dendorfer, Sebastian T1 - Influence of vertebral parameters on lumbar spine loading T2 - Pre-meeting SpineFX, Eurospine 2013, Liverpool, UK Y1 - 2013 ER - TY - JOUR A1 - Hoenicka, M. A1 - Lehle, Karla A1 - Jacobs, V. R. A1 - Dendorfer, Sebastian A1 - Kostorz, A. A1 - Schmid, F. X. A1 - Birnbaum, D. E. T1 - Mechanical and seeding properties of human umbilical vein – a potential scaffold for a tissue-engineered vessel graft JF - The Thoracic and Cardiovascular Surgeon N2 - Objectives: The mechanical properties and seeding with endothelial cells were investigated in fresh and cryopreserved human umbilical vein. Methods: Human umbilical veins (HUV) were frozen in Euro-Collins/1M DMSO at –1°C/min and stored in liquid nitrogen. Stress-strain relationships of fresh and thawed veins were determined in an uniaxial tension-testing rig. HUV endothelial cells (HUVEC) were seeded onto denuded HUV under static conditions and grown for 3d. Luminal surfaces were analyzed by scanning electron microscopy. Calcein-stained cells were seeded hyperconfluently to determine the cell retention capacity of fresh and cryopreserved veins. Results: The stress-strain relationships of HUV followed a biphasic pattern typical for natural vessels. Neither the failure stress (2.71±0.36 vs. 3.25±0.97 N, n=3) nor the displacement required to achieve failure (9.73±0.9 vs. 7.43±2.07mm, n=3) were altered by cryopreservation. The burst pressure was estimated as approx. 1000mm Hg within the limitations of the uniaxial model. HUVEC seeded onto denuded HUV formed patches (at 9E3 cells per cm2) or an almost confluent endothelium (at 3E4 cells per cm2) within three days. The capacity to retain seeded HUVEC of denuded HUV was not altered by cryopreservation (1.15±0.08E5 vs. 1.26±0.14E5 cells per cm2, n=6). Conclusions: The burst pressure of HUV seems to be sufficiently high for the human arterial circulation and is not altered by cryopreservation. HUVEC can establish a confluent endothelium on denuded HUV. Therefore HUV appears to be a suitable storable scaffold for vascular tissue engineering. KW - Nabelvene KW - Tissue Engineering Y1 - 2007 U6 - https://doi.org/10.1055/s-2007-967592 VL - 55 IS - S 1 SP - P_37 PB - Thieme ER - TY - JOUR A1 - Englert, Carsten A1 - Angele, Peter A1 - Fierlbeck, J. A1 - Dendorfer, Sebastian A1 - Schubert, T. A1 - Müller, R. A1 - Lienhard, S. A1 - Zellner, J. A1 - Nerlich, Michael A1 - Neumann, Carsten T1 - Conductive bone substitute material with variable antibiotic delivery JF - Der Unfallchirurg N2 - A new bone substitute, consisting of hydroxylapatite and calcium sulphate, was prepared in two formulations and analysed for its mechanical strength and antibiotic elution.The bone substitute PerOssal has osteoconductive and degradable properties. The material has a built-in capillary structure, which results in an immediate fluid uptake. Antibiotics absorbed to the bone substitute resulted in a prolonged release rate. Mechanical strength was investigated by an unconfined compression test up to failure under both wet and dry conditions for both formulations of the bone substitute. Antibiotic release was analysed microbiologically for two antibiotics, vancomycin and gentamicin, over an elution period of 10 days using the agar diffusion method.The drug release analysis resulted in a prolonged release rate of both antibiotics over 10 days. In vitro the amount of gentamicin and vancomycin eluted at day 10. From one pellet still exceeded the minimal inhibitory concentration of most aetiologically important pathogens. Formulation two of the present bone substitute is significantly harder in both wet and dry conditions when compared to formulation one. Both formulations lose strength in the wet condition relative to their performance in the dry condition. However, formulation two is as hard under wet conditions as formulation one is when dry.PerOssal is a suitable new degradable osteoconductive bone substitute that can be loaded with antibiotic solutions, which are released in effective doses over 10 days. The mechanical strength of PerOssal is sufficient to support cancellous bone defects in non-weight-bearing areas or in combination with osteosynthesis. KW - Knochenersatz KW - Leitfähgkeit KW - Antibiotika KW - Biomechanik KW - Bone substitute materials KW - Osteoconductive KW - Osteomyelitis KW - Multiresistant KW - Biomechanics Y1 - 2007 U6 - https://doi.org/10.1007/s00113-007-1229-3 VL - 110 IS - 5 SP - 408 EP - 413 PB - Springer ER - TY - JOUR A1 - Dendorfer, Sebastian A1 - Maier, Hans Jürgen A1 - Hammer, Josef T1 - Fatigue damage in cancellous bone: an experimental approach from continuum to micro scale JF - Journal of the Mechanical Behavior of Biomedical Materials N2 - Repeated loadings may cause fatigue fractures in bony structures. Even if these failure types are known, data for trabecular bone exposed to cyclic loading are still insufficient as the majority of fatigue analyses on bone concentrate on cortical structures. Despite its highly anisotropic and inhomogeneous structure, trabecular bone is treated with continuum approaches in fatigue analyses. The underlying deformation and damage mechanism within trabecular specimens are not yet sufficiently investigated. In the present study different types of trabecular bone were loaded in monotonic and cyclic compression. In addition to the measurement of integral specimen deformations, optical deformation analysis was employed in order to obtain strain distributions at different scale levels, from the specimens' surface to the trabeculae level. These measurements allowed for the possibility of linking the macroscopic and microscopic mechanical behaviour of cancellous bone. Deformations were found to be highly inhomogeneous across the specimen. Furthermore strains were found to already localise at very low load levels and after few load cycles. Microcracks in individual trabeculae were induced in the very early stage of cyclic testing. The results provide evidence of the capability of the method to supply essential data on the failure behaviour of individual trabeculae in future studies. KW - Knochen KW - Spongiosa KW - Ermüdungsbruch KW - Fatigue KW - Cancellous bone KW - Deformation behaviour KW - Damage KW - Measurement and testing KW - Mechanical behaviour Y1 - 2009 U6 - https://doi.org/10.1016/j.jmbbm.2008.03.003 VL - 2 IS - 1 SP - 113 EP - 119 ER - TY - CHAP A1 - Jungtäubl, Dominik A1 - Aurbach, Maximilian A1 - Melzner, Maximilian A1 - Spicka, Jan A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - EMG-Based Validation of Musculoskeletal Models Considering Crosstalk T2 - International Conference BIOMDLORE, June 28 - 30 2018, Białystok, Poland N2 - BACKGROUND: Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG. OBJECTIVE: This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS: For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets. RESULTS: The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account. CONCLUSIONS: Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough. KW - musculoskeletal modeling KW - validation KW - surface electromyography KW - crosstalk Y1 - 2018 U6 - https://doi.org/10.1109/BIOMDLORE.2018.8467211 ER - TY - CHAP A1 - Dendorfer, Sebastian A1 - Hammer, Joachim A1 - Lenich, Andreas ED - Lee, T. Clive ED - Niederer, Peter F. T1 - Characterisation and testing of biomaterials T2 - Basic Engineering for Medics and Biologists: An ESEM Primer KW - Biomaterial KW - Werkstoff KW - Test Y1 - 2010 SN - 978-1607505266 IS - Chapter IV.4. PB - Non Basic Stock Line ER - TY - CHAP A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - The influence of mental stress on spinal disc loading and muscle activity T2 - 23th Congress of the European Society of Biomechanics, Sevilla, Spain, 2017 Y1 - 2017 ER - TY - CHAP A1 - Melzner, Maximilian A1 - Engelhardt, Lucas A1 - Havelkova, Leonard A1 - Simon, Ulrich A1 - Dendorfer, Sebastian T1 - A new musculoskeletal AnyBody detailed hand model validated by electromyography T2 - 16th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) 2019, New York City, USA N2 - The AnyBody™ Modeling System (AMS) [1], is an universally used musculoskeletal simulation software using inverse dynamics. Until now, no complete human hand model is known in the AMS. Also considering other musculoskeletal software platforms, just one detailed entire hand model is recently published [2] but is only based on one subject. The aim of this work is to implement a full detailed hand model for the AMS including all extrinsic and intrinsic muscles using data by the UWB gained through an anatomical study of ten cadaver hands. Y1 - 2019 UR - https://www.researchgate.net/publication/336944957_A_NEW_MUSCULOSKELETAL_ANYBODY_DETAILED_HAND_MODEL_VALIDATED_BY_ELECTROMYOGRAPHY ER - TY - GEN A1 - Auer, Simon A1 - Niebler, Michael A1 - Eiglsperger, Josef A1 - Kubowitsch, Simone A1 - Renkawitz, Tobias A1 - Achenbach, Leonard A1 - Krutsch, Werner A1 - Dendorfer, Sebastian T1 - Cognitive stress increases muscle forces in dynamic football specific movements T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - CHAP A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Rasmussen, John A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - The influence of cognitive stress on muscle activation and spinal disc load T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - GEN A1 - Melzner, Maximilian A1 - Engelhardt, Leonard A1 - Süß, Friedrich A1 - Dendorfer, Sebastian T1 - Sensitivity evaluation of a musculoskeletal hand model using Latin hypercube sampling T2 - ESMAC 2020 Abstracts Y1 - 2020 U6 - https://doi.org/10.1016/j.gaitpost.2020.08.008 VL - 81 IS - Suppl. 1 PB - Elsevier ER - TY - CHAP A1 - Gross, Simon A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - Investigation of external load dependent static and dynamic muscle fatigue T2 - 23th Congress of the European Society of Biomechanics, Sevilla, Spain, 2017 Y1 - 2017 ER - TY - CHAP A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Jansen, Petra A1 - Dendorfer, Sebastian T1 - Comparison of dynamic muscular imbalances in back pain patients and healthy controls T2 - World Congress Biomechanics Dublin, 2018 Y1 - 2018 ER - TY - CHAP A1 - Seefried, C. A1 - Aurbach, Maximilian A1 - Wyss, C. A1 - Dendorfer, Sebastian T1 - Achilles tendon lengthening alters stresses in the growth plate T2 - International Conference BIOMDLORE, June 28 - 30 2018, Białystok, Poland Y1 - 2018 ER - TY - CHAP A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Jansen, Petra A1 - Dendorfer, Sebastian T1 - Muscular imbalances during experimentally induced stress T2 - 23th Congress of the European Society of Biomechanics, Sevilla, Spain, 2017 Y1 - 2017 ER - TY - GEN A1 - Engelhardt, Lucas A1 - Melzner, Maximilian A1 - Havelkova, Linda A1 - Fiala, Pavel A1 - Rybarova, Martina A1 - Christen, Patrik A1 - Dendorfer, Sebastian A1 - Simon, Ulrich T1 - A new musculoskeletal AnyBody detailed hand model T2 - European Society of Biomechanics meeting 2019, Vienna, Austria N2 - The AnyBody™ Modeling System (AMS) [1], is an universally used musculoskeletal simulation software using inverse dynamics. Until now, no complete human hand model is known in the AMS. Also considering other musculoskeletal software platforms, just one detailed entire hand model is recently published [2] but is only based on one subject. The aim of this work is to implement a full detailed hand model for the AMS including all extrinsic and intrinsic muscles using data by the UWB gained through an anatomical study of ten cadaver hands. Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - JOUR A1 - Weber, Tim A1 - Dullien, Silvia A1 - Grifka, Joachim A1 - Renkawitz, Tobias A1 - Dendorfer, Sebastian T1 - Validation of a Motion Capture Laboratory and a new marker-placement protcol for clinical applications JF - Gait & Posture Y1 - 2013 U6 - https://doi.org/10.1016/j.gaitpost.2013.07.229 VL - 38 IS - Suppl. 1 SP - 113 EP - 114 ER - TY - GEN A1 - Aurbach, Maximilian A1 - Spicka, Jan A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Musculoskeletal modelling of the shoulder – effects on muscle recruitment and joint reaction force T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - CHAP A1 - Weber, Tim A1 - Dullien, Silvia A1 - Putzer, Michael A1 - Dendorfer, Sebastian A1 - Renkawitz, Tobias T1 - Biomechanical outcome after computer-assisted vs. conventional THR – study concept and preliminary gait analysis results T2 - GAMMA Workshop, Hannover, 2012 Y1 - 2012 ER - TY - GEN A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Jansen, Petra A1 - Dendorfer, Sebastian T1 - Effect of dual tasking on muscular imbalances T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER -