TY - JOUR A1 - Schmitz, Paul A1 - Neumann, Christoph Cornelius A1 - Neumann, Carsten A1 - Nerlich, Michael A1 - Dendorfer, Sebastian T1 - Biomechanical analysis of iliac crest loading following cortico-cancellous bone harvesting JF - Journal of Orthopaedic Surgery and Research N2 - Background Iliac crest bone harvesting is a frequently performed surgical procedure widely used to treat bone defects. The objective of this study is to assess the biomechanical quantities related to risk for pelvic fracture after harvesting an autologous bone graft at the anterior iliac crest. Methods Finite element models with a simulated harvest site (sized 15 × 20 mm, 15 × 35 mm, 30 × 20 mm and 30 × 35 mm) in the iliac wing are created. The relevant loading case is when the ipsilateral leg is lifted off the ground. Musculoskeletal analysis is utilized to compute the muscle and joint forces involved in this motion. These forces are used as boundary conditions for the finite element analyses. Bone tissue stress is analyzed. Results Critical stress peaks are located between the anterior superior iliac spine (ASIS) and the anterior edge of the harvest site. Irrespective of the graft size, the iliac wing does not show any significant stress peaks with the harvest site being 20 to 25 mm posterior to the ASIS. The harvest area itself inhibits the distribution of the forces applied on the ASIS to extend to the posterior iliac wing. This leads to a lack of stress posterior to the harvest site. A balanced stress distribution with no stress peaks appears when the bone graft is taken below the iliac crest. Conclusion A harvest site located at least 20 to 25 mm posterior to the ASIS should be preferred to minimize the risk of iliac fatigue fracture. KW - Bone harvesting KW - Autologous bone graft KW - Iliac crest KW - Fatigue fracture KW - Pelvis KW - ASIS KW - FEA KW - Biomechanical investigation KW - Beckenkammknochen KW - Knochenentnahme KW - Spongiosa KW - Biomechanische Analyse Y1 - 2018 U6 - https://doi.org/10.1186/s13018-018-0822-1 VL - 13 IS - 108 SP - 1 EP - 8 PB - Springer Nature ER - TY - CHAP A1 - Horner, Marc A1 - Dendorfer, Sebastian A1 - Kiis, Arne A1 - Lawrenchuk, Mike A1 - Verma, Gunjan T1 - A Patient based simulation workflow for orthopedic device design and analysis T2 - SBC Ortho Workshop, June 2011 Y1 - 2011 ER - TY - CHAP A1 - Dendorfer, Sebastian T1 - The effect of multifidus muscles atrophy following disc herniation on disc loading T2 - Deutsche Gesellschaft für Biomechanik, Murnau, 2011 Y1 - 2011 ER - TY - GEN A1 - Melzner, Maximilian A1 - Ismail, Khaled A1 - Rušavý, Zdeněk A1 - Kališ, Vladimír A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Musculoskeletal Lower Back Load of Accoucheurs During Delivery T2 - 26th Congress of the European Society of Biomechanics, July 11-14, 2021, Milan, Italy N2 - With the progress in modern medicine, it was possible to significantly reduce the risks of birth for mother and child. One aspect that has received less attention so far is the risk of injury to the accoucheurs (obstetricians and midwives) during the birth process. Indeed, studies indicate that 92% of midwives suffer from musculoskeletal disorders, with the lower back being the main cause of complaints (72%). The aim of this study was to investigate two commonly used postural techniques used by accoucheurs during childbirth and to analyze the resulting load on the lower back using the AnyBodyTM musculoskeletal simulation software. Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-20208 CY - Milan ER - TY - CHAP A1 - Aurbach, Maximilian A1 - Jungtäubl, Dominik A1 - Spicka, Jan A1 - Dendorfer, Sebastian T1 - EMG-based validation of musculoskeletal models considering crosstalk T2 - World Congress Biomechanics, 28-30 June 2018, Dublin N2 - BACKGROUND: Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG. OBJECTIVE: This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS: For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets. RESULTS: The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account. CONCLUSIONS: Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough. Y1 - 2018 U6 - https://doi.org/10.1109/BIOMDLORE.2018.8467211 ER - TY - VIDEO A1 - Auer, Simon A1 - Reinker, Lukas A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Krutsch, Werner A1 - Weber, Markus A1 - Renkawitz, Tobias A1 - Dendorfer, Sebastian T1 - Webcast: Effect of mental demand on leg loading in highly dynamic motion N2 - Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury. KW - Webcast KW - AnyBody KW - Stress KW - Football KW - Speedcourt Y1 - 2020 UR - https://www.youtube.com/watch?v=uSc_9XlnkaA ER - TY - GEN A1 - Dendorfer, Sebastian T1 - The influence of modeling parameters in the AnyBody Modeling System on muscle and joint loading in the shoulder T2 - International Shoulder Group Meeting Y1 - 2021 VL - 05 ER - TY - GEN A1 - Eger, Maximilian A1 - Bergstraesser, Marcel A1 - Dendorfer, Sebastian A1 - Lenich, Andreas A1 - Pfeifer, Christian T1 - Influence of radial head prosthetic design on humeroradial stability: Validation of a test rig therefore T2 - DOKU2022, Deutscher Kongress für Orthopädie und Unfallchirurgie, 25.-28. 10.2022, Berlin KW - radial head prostheses KW - humeroradial stability KW - radial head arthroplasty KW - subluxation Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0183-22dkou6115 PB - German Medical Science GMS Publishing House CY - Düsseldorf ER - TY - JOUR A1 - Weber, Markus A1 - Merle, Christian A1 - Nawabi, Danyal H. A1 - Dendorfer, Sebastian A1 - Grifka, Joachim A1 - Renkawitz, Tobias T1 - Inaccurate offset restoration in total hip arthroplasty results in reduced range of motion JF - Scientific Reports N2 - Offset restoration in total hip arthroplasty (THA) is associated with postoperative range of motion (ROM) and gait kinematics. We aimed to research into the impact of high offset (HO) and standard stems on postoperative ROM. 121 patients received cementless THA through a minimally-invasive anterolateral approach. A 360° hip ROM analysis software calculated impingement-free hip movement based on postoperative 3D-CTs compared to ROM values necessary for activities of daily living (ADL). The same model was then run a second time after changing the stem geometry between standard and HO configuration with the implants in the same position. HO stems showed higher ROM for all directions between 4.6 and 8.9° (p < 0.001) compared with standard stems but with high interindividual variability. In the subgroup with HO stems for intraoperative offset restoration, the increase in ROM was even higher for all ROM directions with values between 6.1 and 14.4° (p < 0.001) compared to offset underrestoration with standard stems. Avoiding offset underrestoration resulted in a higher amount of patients of over 20% for each ROM direction that fulfilled the criteria for ADL (p < 0.001). In contrast, in patients with standard stems for offset restoration ROM did increase but not clinically relevant by offset overcorrection for all directions between 3.1 and 6.1° (p < 0.001). Offset overcorrection by replacing standard with HO stems improved ROM for ADL in a low number of patients below 10% (p > 0.03). Patient-individual restoration of offset is crucial for free ROM in THA. Both over and underrestoration of offset should be avoided. KW - Adaptive clinical trial KW - Bone imaging Y1 - 2020 U6 - https://doi.org/10.1038/s41598-020-70059-1 VL - 10 IS - 13208 SP - 9 PB - Nature ER - TY - GEN A1 - Melzner, Maximilian A1 - Pfeifer, Christian A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Muskuloskeletal analysis of elbow stability for common injury patterns T2 - 27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal Y1 - 2022 UR - https://drive.google.com/uc?id=1RBguxyHZE-Wr2y6ktOWK06_3lQg2M9Rb&export=download&confirm=t SP - 654 ER -