TY - CHAP A1 - Souza Jr., Luis Antonio de A1 - Afonso, Luis Claudio Sugi A1 - Palm, Christoph A1 - Papa, João Paulo T1 - Barrett's Esophagus Identification Using Optimum-Path Forest T2 - Proceedings of the 30th Conference on Graphics, Patterns and Images Tutorials (SIBGRAPI-T 2017), Niterói, Rio de Janeiro, Brazil, 2017, 17-20 October N2 - Computer-assisted analysis of endoscopic images can be helpful to the automatic diagnosis and classification of neoplastic lesions. Barrett's esophagus (BE) is a common type of reflux that is not straight forward to be detected by endoscopic surveillance, thus being way susceptible to erroneous diagnosis, which can cause cancer when not treated properly. In this work, we introduce the Optimum-Path Forest (OPF) classifier to the task of automatic identification of Barrett'sesophagus, with promising results and outperforming the well known Support Vector Machines (SVM) in the aforementioned context. We consider describing endoscopic images by means of feature extractors based on key point information, such as the Speeded up Robust Features (SURF) and Scale-Invariant Feature Transform (SIFT), for further designing a bag-of-visual-wordsthat is used to feed both OPF and SVM classifiers. The best results were obtained by means of the OPF classifier for both feature extractors, with values lying on 0.732 (SURF) - 0.735(SIFT) for sensitivity, 0.782 (SURF) - 0.806 (SIFT) for specificity, and 0.738 (SURF) - 0.732 (SIFT) for the accuracy. KW - Speiseröhrenkrankheit KW - Diagnose KW - Maschinelles Lernen KW - Bilderkennung KW - Automatische Klassifikation Y1 - 2017 U6 - https://doi.org/10.1109/SIBGRAPI.2017.47 SP - 308 EP - 314 ER - TY - CHAP A1 - Zehner, Alexander A1 - Szalo, Alexander Eduard A1 - Palm, Christoph T1 - GraphMIC: Easy Prototyping of Medical Image Computing Applications T2 - Interactive Medical Image Computing (IMIC), Workshop at the Medical Image Computing and Computer Assisted Interventions (MICCAI 2015), 2015, Munich N2 - GraphMIC is a cross-platform image processing application utilizing the libraries ITK and OpenCV. The abstract structure of image processing pipelines is visually represented by user interface components based on modern QtQuick technology and allows users to focus on arrangement and parameterization of operations rather than implementing the equivalent functionality natively in C++. The application's central goal is to improve and simplify the typical workflow by providing various high level features and functions like multi threading, image sequence processing and advanced error handling. A built-in python interpreter allows the creation of custom nodes, where user defined algorithms can be integrated to extend basic functionality. An embedded 2d/3d visual-izer gives feedback of the resulting image of an operation or the whole pipeline. User inputs like seed points, contours or regions are forwarded to the processing pipeline as parameters to offer semi-automatic image computing. We report the main concept of the application and introduce several features and their implementation. Finally, the current state of development as well as future perspectives of GraphMIC are discussed KW - Bildverarbeitung KW - Medizin Y1 - 2015 U6 - https://doi.org/10.13140/RG.2.1.3718.4725 N1 - Open-Access-Publikation SP - 395 EP - 400 ER - TY - CHAP A1 - Weber, Joachim A1 - Doenitz, Christian A1 - Brawanski, Alexander A1 - Palm, Christoph T1 - Data-Parallel MRI Brain Segmentation in Clinicial Use BT - Porting FSL-Fastv4 to GPGPUs T2 - Bildverarbeitung für die Medizin 2015; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 15. bis 17. März 2015 in Lübeck N2 - Structural MRI brain analysis and segmentation is a crucial part in the daily routine in neurosurgery for intervention planning. Exemplarily, the free software FSL-FAST (FMRIB’s Segmentation Library – FMRIB’s Automated Segmentation Tool) in version 4 is used for segmentation of brain tissue types. To speed up the segmentation procedure by parallel execution, we transferred FSL-FAST to a General Purpose Graphics Processing Unit (GPGPU) using Open Computing Language (OpenCL) [1]. The necessary steps for parallelization resulted in substantially different and less useful results. Therefore, the underlying methods were revised and adapted yielding computational overhead. Nevertheless, we achieved a speed-up factor of 3.59 from CPU to GPGPU execution, as well providing similar useful or even better results. KW - Brain Segmentation KW - Magnetic Resonance Imaging KW - Parallel Execution KW - Voxel Spacing KW - General Purpose Graphic Processing Unit KW - Kernspintomografie KW - Gehirn KW - Bildsegmentierung KW - Parallelverarbeitung Y1 - 2015 U6 - https://doi.org/10.1007/978-3-662-46224-9_67 SP - 389 EP - 394 PB - Springer CY - Berlin ER - TY - GEN A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph ED - Handels, Heinz ED - Deserno, Thomas M. ED - Maier, Andreas ED - Maier-Hein, Klaus H. ED - Palm, Christoph ED - Tolxdorff, Thomas T1 - Abstract: Imitating Human Soft Tissue with Dual-Material 3D Printing T2 - Bildverarbeitung für die Medizin 2019, Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 17. bis 19. März 2019 in Lübeck N2 - Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. KW - Handchirurgie KW - 3D-Druck KW - Lernprogramm KW - HaptiVisT Y1 - 2019 SN - 978-3-658-25325-7 U6 - https://doi.org/10.1007/978-3-658-25326-4_48 SP - 218 PB - Springer Vieweg CY - Wiesbaden ER - TY - GEN A1 - Rückert, Tobias A1 - Rieder, Maximilian A1 - Rauber, David A1 - Xiao, Michel A1 - Humolli, Eg A1 - Feussner, Hubertus A1 - Wilhelm, Dirk A1 - Palm, Christoph T1 - Augmenting instrument segmentation in video sequences of minimally invasive surgery by synthetic smoky frames T2 - International Journal of Computer Assisted Radiology and Surgery KW - Surgical instrument segmentation KW - smoke simulation KW - unpaired image-to-image translation KW - robot-assisted surgery Y1 - 2023 U6 - https://doi.org/10.1007/s11548-023-02878-2 VL - 18 IS - Suppl 1 SP - S54 EP - S56 PB - Springer Nature ER - TY - JOUR A1 - Maerkl, Raphaela A1 - Rueckert, Tobias A1 - Rauber, David A1 - Gutbrod, Max A1 - Weber Nunes, Danilo A1 - Palm, Christoph T1 - Enhancing generalization in zero-shot multi-label endoscopic instrument classification JF - International Journal of Computer Assisted Radiology and Surgery N2 - Purpose Recognizing previously unseen classes with neural networks is a significant challenge due to their limited generalization capabilities. This issue is particularly critical in safety-critical domains such as medical applications, where accurate classification is essential for reliability and patient safety. Zero-shot learning methods address this challenge by utilizing additional semantic data, with their performance relying heavily on the quality of the generated embeddings. Methods This work investigates the use of full descriptive sentences, generated by a Sentence-BERT model, as class representations, compared to simpler category-based word embeddings derived from a BERT model. Additionally, the impact of z-score normalization as a post-processing step on these embeddings is explored. The proposed approach is evaluated on a multi-label generalized zero-shot learning task, focusing on the recognition of surgical instruments in endoscopic images from minimally invasive cholecystectomies. Results The results demonstrate that combining sentence embeddings and z-score normalization significantly improves model performance. For unseen classes, the AUROC improves from 43.9% to 64.9%, and the multi-label accuracy from 26.1% to 79.5%. Overall performance measured across both seen and unseen classes improves from 49.3% to 64.9% in AUROC and from 37.3% to 65.1% in multi-label accuracy, highlighting the effectiveness of our approach. Conclusion These findings demonstrate that sentence embeddings and z-score normalization can substantially enhance the generalization performance of zero-shot learning models. However, as the study is based on a single dataset, future work should validate the method across diverse datasets and application domains to establish its robustness and broader applicability. KW - Generalized zero-shot learning KW - Sentence embeddings KW - Z-score normalization KW - Multi-label classification KW - Surgical instruments Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-85674 N1 - Corresponding author der OTH Regensburg: Raphaela Maerkl VL - 20 SP - 1577 EP - 1587 PB - Springer Nature ER - TY - CHAP A1 - Klausmann, Leonard A1 - Rueckert, Tobias A1 - Rauber, David A1 - Maerkl, Raphaela A1 - Yildiran, Suemeyye R. A1 - Gutbrod, Max A1 - Palm, Christoph T1 - DIY challenge blueprint: from organization to technical realization in biomedical image analysis T2 - Medical Image Computing and Computer Assisted Intervention - MICCAI 2025 ; Proceedings Part XI N2 - Biomedical image analysis challenges have become the de facto standard for publishing new datasets and benchmarking different state-of-the-art algorithms. Most challenges use commercial cloud-based platforms, which can limit custom options and involve disadvantages such as reduced data control and increased costs for extended functionalities. In contrast, Do-It-Yourself (DIY) approaches have the capability to emphasize reliability, compliance, and custom features, providing a solid basis for low-cost, custom designs in self-hosted systems. Our approach emphasizes cost efficiency, improved data sovereignty, and strong compliance with regulatory frameworks, such as the GDPR. This paper presents a blueprint for DIY biomedical imaging challenges, designed to provide institutions with greater autonomy over their challenge infrastructure. Our approach comprehensively addresses both organizational and technical dimensions, including key user roles, data management strategies, and secure, efficient workflows. Key technical contributions include a modular, containerized infrastructure based on Docker, integration of open-source identity management, and automated solution evaluation workflows. Practical deployment guidelines are provided to facilitate implementation and operational stability. The feasibility and adaptability of the proposed framework are demonstrated through the MICCAI 2024 PhaKIR challenge with multiple international teams submitting and validating their solutions through our self-hosted platform. This work can be used as a baseline for future self-hosted DIY implementations and our results encourage further studies in the area of biomedical image analysis challenges. KW - Biomedical challenges KW - Image analysis KW - Blueprint KW - Do-It-Yourself KW - Self-hosting Y1 - 2025 SN - 978-3-032-05141-7 U6 - https://doi.org/10.1007/978-3-032-05141-7_9 SP - 85 EP - 95 PB - Springer CY - Cham ER - TY - INPR A1 - Gutbrod, Max A1 - Rauber, David A1 - Weber Nunes, Danilo A1 - Palm, Christoph T1 - OpenMIBOOD: Open Medical Imaging Benchmarks for Out-Of-Distribution Detection N2 - The growing reliance on Artificial Intelligence (AI) in critical domains such as healthcare demands robust mechanisms to ensure the trustworthiness of these systems, especially when faced with unexpected or anomalous inputs. This paper introduces the Open Medical Imaging Benchmarks for Out-Of-Distribution Detection (OpenMIBOOD), a comprehensive framework for evaluating out-of-distribution (OOD) detection methods specifically in medical imaging contexts. OpenMIBOOD includes three benchmarks from diverse medical domains, encompassing 14 datasets divided into covariate-shifted in-distribution, near-OOD, and far-OOD categories. We evaluate 24 post-hoc methods across these benchmarks, providing a standardized reference to advance the development and fair comparison of OOD detection methods. Results reveal that findings from broad-scale OOD benchmarks in natural image domains do not translate to medical applications, underscoring the critical need for such benchmarks in the medical field. By mitigating the risk of exposing AI models to inputs outside their training distribution, OpenMIBOOD aims to support the advancement of reliable and trustworthy AI systems in healthcare. The repository is available at this https URL. Y1 - 2025 U6 - https://doi.org/10.48550/arXiv.2503.16247 N1 - Der Aufsatz wurde peer-reviewed veröffentlicht und ist ebenfalls in diesem Repositorium verzeichnet unter: https://opus4.kobv.de/opus4-oth-regensburg/8467 ER - TY - JOUR A1 - Weiherer, Maximilian A1 - Eigenberger, Andreas A1 - Egger, Bernhard A1 - Brébant, Vanessa A1 - Prantl, Lukas A1 - Palm, Christoph T1 - Learning the shape of female breasts: an open-access 3D statistical shape model of the female breast built from 110 breast scans JF - The Visual Computer N2 - We present the Regensburg Breast Shape Model (RBSM)—a 3D statistical shape model of the female breast built from 110 breast scans acquired in a standing position, and the first publicly available. Together with the model, a fully automated, pairwise surface registration pipeline used to establish dense correspondence among 3D breast scans is introduced. Our method is computationally efficient and requires only four landmarks to guide the registration process. A major challenge when modeling female breasts from surface-only 3D breast scans is the non-separability of breast and thorax. In order to weaken the strong coupling between breast and surrounding areas, we propose to minimize the variance outside the breast region as much as possible. To achieve this goal, a novel concept called breast probability masks (BPMs) is introduced. A BPM assigns probabilities to each point of a 3D breast scan, telling how likely it is that a particular point belongs to the breast area. During registration, we use BPMs to align the template to the target as accurately as possible inside the breast region and only roughly outside. This simple yet effective strategy significantly reduces the unwanted variance outside the breast region, leading to better statistical shape models in which breast shapes are quite well decoupled from the thorax. The RBSM is thus able to produce a variety of different breast shapes as independently as possible from the shape of the thorax. Our systematic experimental evaluation reveals a generalization ability of 0.17 mm and a specificity of 2.8 mm. To underline the expressiveness of the proposed model, we finally demonstrate in two showcase applications how the RBSM can be used for surgical outcome simulation and the prediction of a missing breast from the remaining one. Our model is available at https://www.rbsm.re-mic.de/. KW - Statistical shape model KW - Non-rigid surface registration KW - Breast imaging KW - Surgical outcome simulation KW - Breast reconstruction surgery Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-30506 N1 - Corresponding author: Christoph Palm N1 - Zugehörige arXiv-Publikation: https://opus4.kobv.de/opus4-oth-regensburg/frontdoor/index/index/docId/2023 VL - 39 IS - 4 SP - 1597 EP - 1616 PB - Springer Nature ER - TY - JOUR A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph T1 - Imitating human soft tissue on basis of a dual-material 3D print using a support-filled metamaterial to provide bimanual haptic for a hand surgery training system JF - Quantitative Imaging in Medicine and Surgery N2 - Background: Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D-printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. Methods: The goal of this experiment is to imitate human soft tissue with its haptic and elasticity for a realistic hand phantom fabrication, using only a dual-material 3D printer and support-material-filled metamaterial between skin and bone. We present our workflow to generate lattice structures between hard bone and soft skin with iterative cube edge (CE) or cube face (CF) unit cells. Cuboid and finger shaped sample prints with and without inner hard bone in different lattice thickness are constructed and 3D printed. Results: The most elastic available rubber-like material is too firm to imitate soft tissue. By reducing the amount of rubber in the inner volume through support material (SUP), objects become significantly softer. Without metamaterial, after disintegration, the SUP can be shifted through the volume and thus the body loses its original shape. Although the CE design increases the elasticity, it cannot restore the fabric form. In contrast to CE, the CF design increases not only the elasticity but also guarantees a local limitation of the SUP. Therefore, the body retains its shape and internal bones remain in its intended place. Various unit cell sizes, lattice thickening and skin thickness regulate the rubber material and SUP ratio. Test prints with higher SUP and lower rubber material percentage appear softer and vice versa. This was confirmed by an expert surgeon evaluation. Subjects adjudged pure rubber-like material as too firm and samples only filled with SUP or lattice structure in CE design as not suitable for imitating tissue. 3D-printed finger samples in CF design were rated as realistic compared to the haptic of human tissue with a good palpable bone structure. Conclusions: We developed a new dual-material 3D print technique to imitate soft tissue of the human hand with its haptic properties. Blowy SUP is trapped within a lattice structure to soften rubber-like 3D print material, which makes it possible to reproduce a realistic replica of human hand soft tissue. KW - Dual-material 3D printing KW - Hand surgery training KW - Metamaterial KW - Support material KW - Tissue-imitating hand phantom KW - Handchirurgie KW - 3D-Druck KW - Biomaterial KW - Lernprogramm Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-979 N1 - Corresponding author: Christoph Palm VL - 9 IS - 1 SP - 30 EP - 42 PB - AME Publishing Company ER -