TY - CHAP A1 - Romano, Marco A1 - Micklitz, Matthias A1 - Olbrich, Florian A1 - Bierl, Rudolf A1 - Ehrlich, Ingo A1 - Gebbeken, Norbert T1 - Experimental investigation of damping properties of unidirectionally and fabric reinforces plastics by the free decay method T2 - Proceeding of the 15th International Materials Symposium (IMSP´2014), Pamukkale University (Denizli, Turkey), 15./17. October 2014 Y1 - 2014 SP - 665 EP - 679 ER - TY - INPR A1 - Pangerl, Jonas A1 - Sukul, Pritam A1 - Rück, Thomas A1 - Fuchs, Patricia A1 - Weigl, Stefan A1 - Miekisch, Wolfram A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - An Inexpensive Uv-Led Photoacoustic Based Real-Time Sensor-System Detecting Exhaled Trace-Acetone N2 - In this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) – providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 6.4 ppbV and an NNEA of 1.1E-9 Wcm-1Hz-0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field. KW - photoacoustic spectroscopy KW - real-time mass-spectrometry KW - breath analysis KW - acetone KW - UV-LED Y1 - 2024 U6 - https://doi.org/10.2139/ssrn.4724198 N1 - Der Aufsatz wurde peer-reviewed unter folgender DOI veröffentlicht: https://doi.org/10.1016/j.pacs.2024.100604 PB - Elsevier ER - TY - JOUR A1 - Rück, Thomas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - NO2 trace gas monitoring in air using off-beam quartz enhanced photoacoustic spectroscopy (QEPAS) and interference studies towards CO2, H2O and acoustic noise JF - Sensors and Actuators B: Chemical N2 - We present the development and characterization as well as comprehensive interference studies of a photoacoustic NO2 trace gas detection system. The system is based on an off-beam quartz enhanced photoacoustic scheme (off-beam QEPAS) and signal generation was initiated by amplitude modulating a low-cost diode laser emitting at 450 nm. The QEPAS sensor element features double-resonant amplification, still it is only ∼ 5 × 5 × 2.5 mm in size. The individual and combined resonance characteristics were investigated and specified to 52 dB amplification, adding up 15 dB acoustic- and 37 dB mechanical-resonance amplification. The linearity of the photoacoustic signal dependency on the analyte concentration was verified from 200 ppbV to 100 ppmV NO2 in synthetic air. The detection limit (3σ) was determined to 1.8 ppbV using a lock-in time constant of 10 s and an averaging time of 20 s. The normalized noise equivalent absorption coefficient was specified to 2.5·10−8 W cm−1 Hz−0.5. The stability of the signal was investigated over time and a slight drift by 1‰ was observed after 30 min without temperature stabilizing the photoacoustic cell (PAC). Noise analysis was performed by means of Allan deviation and the inverse dependency of response time and precision of the system on the lock-in time constant was outlined. We performed interference analyses towards N2, O2, CO2, H2O and acoustic noise, respectively. Although neither spectral interferences nor losses due to slow NO2 VT-relaxation were observed, O2 was identified to cause a 15% signal drop due to VVNO2-O2-relaxation. Changing H2O concentrations were found to cause acoustic detuning, which cannot be compensated by adjusting the frequency of modulation, because of the double-resonant feature of the PAC. However, alternative approaches of compensation were discussed. Finally, we carried out heavy traffic noise simulations and determined the QEPAS setup to be 46 times less susceptible towards ambient noise compared to standard microphone-based photoacoustic setups. Y1 - 2018 U6 - https://doi.org/10.1016/j.snb.2017.09.039 VL - 255 IS - Part 3, February SP - 2462 EP - 2471 PB - Elsevier ER - TY - JOUR A1 - Rück, Thomas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Development and characterization of a laboratory setup for photoacoustic NO2 determination based on the excitation of electronic 2B2 and 2B1 states using a low-cost semiconductor laser JF - Sensors and Actuators A: Physical N2 - This work gives a detailed characterization of a laboratory setup for photoacoustic NO2 trace gas detection at the ppb level. The signal generation is based on the excitation of electronic 2B2 and 2B1 states using a low-cost semiconductor laser emitting at 450 nm. An acoustic resonator was used for signal amplification and the modulation frequency of the laser was determined to 3395 Hz in order to gain maximum signal amplification. The quality of resonant amplification was determined to 7.9. The gas samples were NO2 calibration gases diluted with pure nitrogen. The signal-to-noise ratio (SNR) dependency on the flow rate Q and the lock-in time constant τLIA was investigated, respectively, and the optimum values were specified to Q = 500 mL/min and τLIA = 2 s. In case of ambient noise, increasing τLIA to 10 s was evaluated as sufficient for SNR preservation. The noise level was measured in the absence of NO2 and it was determined to be composed of 51% electronic noise and 49% gas flow noise. With the analyte concentration ranging from 300 ppbV to 100 ppmV, the linear dependency of the photoacoustic amplitude on the NO2 concentration was specified, the sensitivity was determined to 110 μV/ppmV and the maximum measurement error was calculated to ±0.8%. The detection limit was determined to 2.0 ppbV. Furthermore, the stability of the signal was investigated and a maximum drift of ±1% was observed within a measuring period of 30 min. The response time τ90 was specified to 58 s. All results considered, this photoacoustic measuring system, which is based on low-cost signal generation and detection units, provides an excellent basis in view of developing a portable device for photoacoustic trace gas detection. Y1 - 2017 U6 - https://doi.org/10.1016/j.sna.2017.03.024 VL - 258 SP - 193 EP - 200 PB - Elsevier CY - Amsterdam, Niederlande ER - TY - JOUR A1 - Rück, Thomas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Low-cost photoacoustic NO2 trace gas monitoring at the pptV-level JF - Sensors and Actuators A: Physical N2 - We present the development and the characterization of a photoacoustic NO2 trace gas detection system. The system is based on the implementation of low-cost components, i.e. a mass-produced blue diode laser and a standard MEMS microphone which is commonly built into smartphones, for example. An optimized cell design was realized by means of 3D printing. The linearity of the photoacoustic signal dependency on the analyte concentration was verified from 200 ppbV to 100 ppmV NO2. The detection limit (1σ) was determined to 33 pptV and the normalized noise equivalent absorption coefficient was calculated to 7.0 ∙ 10−10 W cm−1 Hz−1/2. The dynamic range of the system was verified to be linear over three magnitudes of order and the sensitivity was calculated to 814 μV/ppmV. The system was characterized in view of optimal operating parameters, i.e. lock-in time constant τLIA and total mass flow rate, optical performance and signal stability. The mass flow dependend response time of the system was specified to 19 s and an idealized step response to a quasi-Heaviside step function was quantified as a function of τLIA. The quality factor of acoustic resonance was determined to 21.9 and an empirical expression regarding acoustic node shifting is provided. The expression takes into account the radius of the resonator pipe and the radius of the hole, which was drilled into the pipe for microphone coupling. Furthermore, we studied the cross-sensitivity of the photoacoustic signal towards H2O and CO2, respectively. Y1 - 2017 U6 - https://doi.org/10.1016/j.sna.2017.06.036 VL - 263 SP - 501 EP - 509 PB - Elsevier CY - Amsterdam, Niederlande ER - TY - GEN A1 - Weigl, Stefan A1 - Matysik, Frank-Michael A1 - Bierl, Rudolf T1 - Development of a sensor system for analysis of human breath exhale T2 - BayWISS Herbstakademie 2018, Plankstetten N2 - Atemgasanalyse ist ein junges und vielversprechendes Feld im Bereich der diagnostischen Medizin. Der Ansatz verspricht einfach zugängliche und leicht wiederholbare Probennahme die zum einen non-invasiv ist und zugleich Rückschlüsse auf Vorgänge im menschlichen Körper und bspw. dessen Gesundheitszustand zulässt. Seit Ende des 20. Jahrhunderts gibt es Massenspektrometer die es ermöglicht haben mehrere Tausend verschiedene Stoffe in der Ausatemluft nachzuweisen. Diese Technologien verbessern sich stetig und ermöglichen es die Vorgänge und Zusammenhänge zwischen Zusammensetzung der Ausatemluft und systemischen Prozessen besser zu verstehen. Die bei Studien mit Massenspektrometern ermittelten Biomarker, deren qualitative und quantitative Detektion Gesundheitsdiagnosen ermöglichen, haben aber noch nicht den Weg in den klinischen Alltag gefunden. Das Problem sind meistens die hohen Anschaffungskosten, komplizierte Datenauswertung und zumeist geringe Verfügbarkeit und Immobilität dieser Messgeräte. Die photoakustische Spektroskopie ist eine selektive und hochsensitive Messmethode, die es ermöglichen soll den Biomarker „Aceton“, der grundsätzlich die Metabolisierung von Fetten widerspiegelt, schnell und reproduzierbar quantitativ zu detektieren. Dabei müssen Hindernisse wie Querempfindlichkeiten, ausgelöst durch die komplexe Zusammensetzung der Messmatrix Atemgas, bei gleichzeitig kleine Aceton Konzentrationen (200-800 parts-per-billion) überwunden werden. Verschiedene Wellenlängenbereiche mit unterschiedlichen Lichtquellen, akustisch resonante sowie innovative Messzellendesigns und anspruchsvolle Datenauswertung mittels komplexer Algorithmik sind nötig um das Ziel, die Entwicklung eines kompakten, günstigen und zuverlässigen Acetonsensors, zu erreichen. Y1 - 2018 ER - TY - CHAP A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf T1 - Einbindung eines 2D-Photodetektors in einen hochintegrierten SPR-Imaging-Sensor T2 - 118. Jahrestagung der deutschen Gesellschaft für angewandte Optik (DGaO), 6.-10. Juni 2017, Dresden N2 - Mit der Oberflächenplasmonenresonanzspektroskopie (SPR) können Brechungsindexänderungen eines Analyten von bis zu 10-6 RIU detektiert werden. Das SPR-Imaging bietet heute gegenüber der konventionellen SPR-Analyse die Möglichkeit, mehrere einzelne Messungen parallel durchführen zu können. Mit Hilfe eines zweidimensionalen Sensorchips und einer leistungsfähigen Boardlevelkamera können die Abbildungen des Chips direkt an einen Rechner übertragen und dort verarbeitet werden. Aufgrund unterschiedlicher Winkelstellungen und der Geometrie des Aufbaus entstehen Stauchungen und Streckungen des abgebildeten Sensorchips, die mit verschiedenen Ansätzen aus der Bildverarbeitung ausgeglichen werden, um die Bilder miteinander vergleichen zu können. Zudem wird die Güte der Referenz- und Messbereiche des Chips bestimmt. Diese Algorithmen sind nur möglich aufgrund der heutigen, leistungsfähigen Rechner und der immer größer werdenden Durchsatzraten der Kameras. Dabei kommt in dieser Anwendung der relativ neue Kamerastandard USB3 Vision zum Einsatz. Dieser zeichnet sich zusätzlich durch das Plug and Play und seinen Standardstecker, der an (fast) jedem Rechner vorhanden ist, aus. KW - Bildverarbeitung KW - Messtechnik KW - Optische Informationsverarbeitung Y1 - 2017 ER - TY - CHAP A1 - Zhou, Qi A1 - Landgraf, Ferdinand A1 - Rück, Thomas A1 - Bierl, Rudolf T1 - Resonance frequency tuning and process design of a micromechanical capacitive cantilever in a photoacoustic trace-gas sensing device T2 - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München N2 - Photoacoustic spectroscopy is an efficient method to detect the concentration of trace gases with following advantages: short response time, high sensitivity, continuous and real-time monitoring and the option of miniaturization without the need of complex mirror-based multi-pass cell designs. A micromechanical cantilever is used as a key component in a two-part "Cantilever-Resonator" system that detects the weak photoacoustic signal. The resonance frequency of cantilever needs to be tuned to match the resonance frequency of resonator in order to achieve the maximum vibration amplitude of the "Cantilever-Resonator" system. This paper reports a post-fabrication method to tune the resonance frequency of cantilevers via focused ion beam (FIB) and a capacitive solution for the cantilever to transform the acoustic signal to electrical signal. Y1 - 2017 SN - 978-3-8007-4491-6 PB - VDE-Verlag CY - Berlin ER - TY - JOUR A1 - van der Weerd, Bastiaan A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Trends in Electrochemical Sensing of Blood Gases JF - Bioanalytical Reviews N2 - The monitoring of partial pressures of the blood gases carbon dioxide (pCO2) and oxygen (pO2) is of great importance in clinical diagnostics. The measure of pCO2 and pO2 provides essential information about the patient’s metabolism, gas exchange, ventilation, and acid–base homeostasis. The conventional electrochemical methods for clinical blood gas analysis are based on the potentiometric Severinghaus sensor for carbon dioxide and the amperometric Clark sensor for oxygen. These techniques are well established and are only shortly discussed in this overview. However, in recent years a variety of modifications of these classical sensor concepts and new approaches of electrochemical sensing of pCO2 and pO2 have been introduced. This review summarizes recent developments in this field and discusses the potential for future applications in clinical blood gas analysis. KW - Blood gas analysis KW - Noninvasive blood gas sensor KW - Electrochemical sensor KW - Clinical analysis Y1 - 2016 U6 - https://doi.org/10.1007/11663_2016_1 VL - 6 SP - 263 EP - 280 PB - Springer CY - Berlin ER - TY - CHAP A1 - Rück, Thomas A1 - Läpple, I. A1 - Bierl, Rudolf T1 - Photoakustische Spurengasanalytik von NO2 im ppt-Bereich (10^-12) bei Verwendung kostengünstiger Einzelkomponenten T2 - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München KW - Elektroniksystem KW - Industrie 4.0 KW - Mikrosystemtechnik KW - Mikrofluidik KW - Mikroaktorik Y1 - 2017 SN - 978-3-8007-4491-6 PB - VDE-Verlag CY - Berlin ER - TY - JOUR A1 - Zagler, Andreas A1 - Landgraf, Ferdinand A1 - Rück, Thomas A1 - Bierl, Rudolf T1 - Entwicklung eines mikromechanischen kapazitiven Schalldetektors im resonanten Betrieb für die photoakustische Spurengasanalyse JF - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München Y1 - 2017 PB - VDE-Verlag CY - Berlin ER - TY - CHAP A1 - Gaida, Peter A1 - Weigl, Stefan A1 - Rück, Thomas A1 - Bierl, Rudolf T1 - Portable photoakustische Messeinheit zur NO2 Detektion im Spurenbereich T2 - 7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München Y1 - 2017 SN - 978-3-8007-4491-6 PB - VDE-Verlag CY - Berlin ER - TY - GEN A1 - Hausler, Peter A1 - Roth, Carina A1 - Vitzthumecker, Thomas A1 - Fischer, Johannes A1 - Bierl, Rudolf T1 - Motionless SPR-angle scan with a miniaturized device T2 - Europtrode XIV, Naples, 25-28 March 2018 Y1 - 2018 ER - TY - CHAP A1 - Weigl, Stefan A1 - Gaida, Peter A1 - Rück, Thomas A1 - Bierl, Rudolf T1 - Portable Measurement Unit for NO2 Trace Gas Detection T2 - PHOTOPTICS 2018, 6th International Conference on Photonics, Optics and Laser Technology, 25 - 27 January 2018, Funchal Madeira Y1 - 2018 ER - TY - RPRT A1 - Unger, J. A1 - Rück, Thomas A1 - Landgraf, Ferdinand A1 - Bierl, Rudolf T1 - Herstellung und Analyse der Resonanzfrequenz eines MEMS Cantilever für das CEPAS Verfahren N2 - Diese Abhandlung beschreibt das Konzept eines mikroeletromechanischen Systems (MEMS), das im Messverfahren der cantilever enhanced photoacoustic spectroscopy (CEPAS) Verwendung finden soll. Es wird die Herstellung eines einseitig eingespannten Biegebalkens aus Silizium mittels deep reactiv ion etching (DRIE) beschrieben. Des Weiteren wird die Resonanzfrequenz dieses Cantilevers mit Hilfe Laservibrometertechnik untersucht. Die resultierenden resonanten Schwingungen 0.Ordnung werden mit den Ergebnissen einer vereinfachten theoretischen Näherung verglichen. Die Messergebnisse stehen in gutem Zusammenhang mit den theoretischen Werten. Solche Cantilever, die aus silicon on insula tor (SOI) Wafer angefertigt wurden, weisen bei einer Zielfrequenz ein mittlere Abweichung von Δf = 118±26Hz (bzw.Δf =0,76±0,17%) auf. Y1 - 2015 ER - TY - CHAP A1 - Holler, Sven A1 - Hausler, Peter A1 - Roth, Carina A1 - Bierl, Rudolf T1 - Gestapelte Au-Al-Au und Au-Ag-Au Schichten als aktive Schichten für die Oberflächenplasmonenresonanzspektroskopie T2 - 5. Landshuter Symposium Mikrosystemtechnik, März 2016 Y1 - 2016 SN - 978-3-9812696-9-7 SP - 192 EP - 198 PB - Fachhochschule Landshut CY - Landshut ER - TY - CHAP A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf T1 - Einbindung eines CMOS-Detektors in einen hochintegrierten SPR-Sensor T2 - 5. Landshuter Symposium Mikrosystemtechnik, März 2016 Y1 - 2016 SN - 78-3-9812696-9-7 SP - 200 EP - 205 PB - Fachhochschule Landshut CY - Landshut ER - TY - JOUR A1 - Romano, Marco A1 - Micklitz, Matthias A1 - Olbrich, Florian A1 - Bierl, Rudolf A1 - Ehrlich, Ingo A1 - Gebbeken, Norbert T1 - Experimental investigation of damping properties of unidirectionally and fabric reinforced plastics by the free decay method JF - Journal of Achievements in Materials and Manufacturing Engineering N2 - Purpose: of this paper is experimental investigation of damping properties of unidirectionally and fabric reinforced plastics by the free decay method. Design/methodology/approach: For the evaluation of the presumed effect experimental structural dynamic investigations comparing unidirectionally and fabric reinforced plastics are carried out. In detail the free decay behaviour of flat beamlike specimens under fixed-free boundary conditions and relatively constant and reproducible displacement excitation is investigated. Findings: The vibrating structure has been measured by a laser scanning vibrometer PSV 400 from POLYTEC. In both cases evaluation of the results yields enhanced damping properties of the specimens with fabric reinforcement compared to the unidirectionally reinforced specimens. The results justify the presumed acting of a mesomechanic kinematic. Research limitations/implications: The results show that in either case the material damping in terms of the logarithmic decrement of the fabric reinforced material is higher than the material damping in of the unidirectionally reinforced material. Additionally, when the fabric reinforced specimens are addressed, in each case the plain weave reinforced specimens exhibited higher values of the material damping as the twill weave 2/2 reinforced ones. Originality/value: Ondulations in fabrics as a textile semi-finished product are caused by the alternating crossing of warp and fill yarns. In the mesoscopic scale the acting of a mesomechanic kinematic is presumed to enhance the damping properties under cyclic elastic deformation. For the evaluation of the presumed effect experimental structural dynamic investigations comparing unidirectionally and fabric reinforced plastics are carried out. KW - structural vibration KW - damping KW - fibre reinforced plastics KW - mesomechanic scale KW - fabric reinforced layer Y1 - 2014 VL - 63 IS - 2 SP - 65 EP - 80 ER - TY - CHAP A1 - Jobst, Simon A1 - Bierl, Rudolf T1 - A Comparison of Correlation and Zero-Crossing Based Techniques in Ultrasonic Measurement T2 - 10th International Symposium on Applied Reconfigurable Computing (ARC'2014), Vilamoura, Algarve, Portugal, 14 - 16 April, 2014 N2 - Ultrasound measurement technology has advancedin previous decades due to positive developments in computing power and lower cost for the necessary hardware. Correlation-based processing can be advantageous for high-accuracy measurements, especially in noisy environments. Higher computational load makes correlation less attractive for industrialapplications, though, favouring traditional processing techniques. A platform for comparing various processing techniques hasbeen developed. It was found that both zero-crossing detectionas well as correlation can achieve very high accuracy over a hightemperature range but that correlation-based processing can lead to a significant precision bias depending on system bandwidth. Y1 - 2014 ER - TY - CHAP A1 - Hofmann, Matthias A1 - Bierl, Rudolf A1 - Rück, Thomas T1 - Implementation of a dual-phase lock-in amplifier on a TMS320C5515 digital signal processor T2 - Proceedings of the 5th European DSP Education and Research Conference (EDERC), 13-14 Sept. 2012, Amsterdam N2 - A digital dual-phase lock-in amplifier that is capable to run on a low-cost, low-power platform comprising a 16-bit fixed-point digital signal processor was developed. This is achieved by a set of optimised digital filters including an exponential averager to adjust the time constant of the overall filter. The reference frequency is generated using a direct digital synthesis source utilising angle decomposition with a resolution of 1 Hz. The digital lock-in algorithm is described and the performance of the algorithm is analysed. The experimental results show that the developed lock-in amplifier achieves similar performance to a commercially available lock-in amplifier. Y1 - 2012 U6 - https://doi.org/10.1109/EDERC.2012.6532217 ER - TY - CHAP A1 - Rück, Thomas A1 - Landgraf, Ferdinand A1 - Läpple, I. A1 - Unger, J. A1 - Matysik, Frank-Michael A1 - Bierl, Rudolf T1 - Specification of an improved photoacoustic setup for high-sensitive, low-cost NO2 trace gas detection T2 - 18th International Conference on Photoacoustic and Photothermal Phenomena (ICPPP18), 2015, September 6-10, Novi Sad, Serbia Y1 - 2015 ER - TY - CHAP A1 - van der Weerd, Bastiaan A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - A Conductivity Probe for the Determination of Carbon Dioxide Tension at the Oxygenator Exhaust Outlet during Extracorporeal Membrane Oxygenation (ECMO) T2 - analytica Conference 2014, 1. bis 4. April, München Y1 - 2014 ER - TY - CHAP A1 - van der Weerd, Bastiaan A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - A Conductivity Probe for the Determination of Carbon Dioxide Tension at the Oxygenator Exhaust Outlet during Extracorporeal Membrane Oxygenation (ECMO) T2 - Electrochemistry 2014, September 22 - 24, Mainz Y1 - 2014 ER - TY - CHAP A1 - van der Weerd, Bastiaan A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - A Planar Conductivity Probe for CO2 Determination at the Oxygenator Outlet T2 - Doktorandenseminar GDCh Prozessanalytik 2014, Berlin Y1 - 2014 ER - TY - JOUR A1 - Wunderlich, Lukas A1 - Hausler, Peter A1 - Maerkl, Susanne A1 - Bierl, Rudolf A1 - Hirsch, Thomas T1 - Nanoparticle Determination in Water by LED-Excited Surface Plasmon Resonance Imaging JF - Chemosensors N2 - The increasing popularity of nanoparticles in many applications has led to the fact that these persistent materials pollute our environment and threaten our health. An online sensor system for monitoring the presence of nanoparticles in fresh water would be highly desired. We propose a label-free sensor based on SPR imaging. The sensitivity was enhanced by a factor of about 100 by improving the detector by using a high-resolution camera. This revealed that the light source also needed to be improved by using LED excitation instead of a laser light source. As a receptor, different self-assembled monolayers have been screened. It can be seen that the nanoparticle receptor interaction is of a complex nature. The best system when taking sensitivity as well as reversibility into account is given by a dodecanethiol monolayer on the gold sensor surface. Lanthanide-doped nanoparticles, 29 nm in diameter and with a similar refractive index to the most common silica nanoparticles were detected in water down to 1.5 mu g mL(-1). The sensor can be fully regenerated within one hour without the need for any washing buffer. This sensing concept is expected to be easily adapted for the detection of nanoparticles of different size, shape, and composition, and upon miniaturization, suitable for long-term applications to monitor the quality of water. KW - ENGINEERED NANOPARTICLES KW - imaging KW - nanoparticle KW - plasmon resonance KW - REFRACTIVE-INDEX KW - sensor KW - surface Y1 - 2021 U6 - https://doi.org/10.3390/chemosensors9070175 SN - 2227-9040 VL - 9 IS - 7 SP - 1 EP - 9 PB - MDPI ER - TY - CHAP A1 - Hausler, Peter A1 - Roth, Carina A1 - Vitzthumecker, Thomas A1 - Bierl, Rudolf ED - Ribeiro, Paulo ED - Raposo, Maria T1 - Miniaturized Surface Plasmon Resonance Based Sensor Systems BT - Opportunities and Challenges T2 - Optics, Photonics and Laser Technology 2018 N2 - Surface Plasmon Resonance (SPR) is a well-known and established technology in bioanalysis and pharmaceutical sciences. Due to the expensive instrumentation and the need of trained people, it is mainly limited to applications in laboratories. However, there are some areas like environmental monitoring, chemical processing and civil infrastructure, which urgently need new sensor technologies. SPR has the potential to serve these fields. In order to be qualified for a use in these areas SPR has to overcome some hurdles. The instrumentation has to be robust, small in size and cheap. A device, which fits these needs, will be a micro-opto-electro-mechanical system (MOEMS) with integrated intelligent algorithms. In this book chapter, examples of miniaturized SPR devices are introduced, the limitations which have to be overcome as well as the possibilities for future applications are proposed. Due to the manifold advantages of this technology and the dropping prices for imaging sensors, Surface Plasmon Resonance imaging (SPRi) might become one of the leading technologies for SPR smart sensor systems. Y1 - 2019 SN - 978-3-030-30112-5 U6 - https://doi.org/10.1007/978-3-030-30113-2_8 SP - 169 EP - 195 PB - Springer Nature CY - Cham ER - TY - INPR A1 - Rück, Thomas A1 - Müller, Max A1 - Jobst, Simon A1 - Weigl, Stefan A1 - Pangerl, Jonas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Digital Twin of a Photoacoustic Trace Gas Sensor for Monitoring Methane in Complex Gas Compositions N2 - The digitalization of industrial processes requires smart sensor systems. Photoacoustic spectroscopy is well suited for this purpose as it allows for small-sized and low-cost trace gas analysis. However, the method is susceptible to changes in measurement conditions and standard calibration routines often fail to correct for all changes. We therefore created a Digital Twin (DT) of a photoacoustic trace gas sensor for methane and evaluated it regarding variations in gas composition (CH4, N2, O2, CO2, H2O), temperature and pressure. With a mean absolute percentage error of 0.8 % the accuracy of the sensor after DT compensation significantly exceeds the 24 % achieved based on standard calibration in nitrogen. For the first time, we can fully analytically compute the photoacoustic signal under moderate ambient conditions with an error in the ppbV range by taking a holistic approach. Assuming knowledge of the underlying energy transfer processes, the model of this Digital Twin can be adapted to any microphone based photoacoustic sensor for monitoring any analyte species. Y1 - 2022 U6 - https://doi.org/10.2139/ssrn.4215170 PB - Elsevier / SSRN ER - TY - CHAP A1 - Müller, Max A1 - Rück, Thomas A1 - Jobst, Simon A1 - Pangerl, Jonas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Creating a Digital Twin of a Photoacoustic Gas Sensor for Methane Detection in Complex Gas Matrices T2 - Proceedings Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES): 11–15 July 2022, Vancouver, British Columbia, Canada N2 - We present the calculation results from a digital twin (DT) of our photoacoustic (PA) sensor for methane detection, regarding gas composition, temperature and pressure variations. Y1 - 2022 SN - 978-1-957171-10-4 U6 - https://doi.org/10.1364/LACSEA.2022.LW4D.2 PB - Optica Publishing Group ER - TY - INPR A1 - Müller, Max A1 - Weigl, Stefan A1 - Müller-Williams, Jennifer A1 - Lindauer, Matthias A1 - Rück, Thomas A1 - Jobst, Simon A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Ambient methane monitoring at Hohenpeißenberg utilizing photoacoustic spectroscopy and cavity ring down spectroscopy N2 - With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10−9) methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective, is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a five day period at Hohenpeißenberg, Germany. As a reference device a calibrated cavity ringdown spectrometer Picarro G2301 from the meteorological observatory was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to environmental influences. The obtained results show that relaxation effects due to fluctuating environmental conditions, e.g. ambient humidity, are a non-negligible factor in PA sensor systems. Applying algorithm compensation techniques, which are capable of calculating the influence of relaxational effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 % from the G2301, the photoacoustic sensor shows good agreement with the reference instrument. Y1 - 2023 U6 - https://doi.org/10.5194/egusphere-2023-1010 ER - TY - JOUR A1 - Rück, Thomas A1 - Müller, Max A1 - Jobst, Simon A1 - Weigl, Stefan A1 - Pangerl, Jonas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Digital Twin of a Photoacoustic Trace Gas Sensor for Monitoring Methane in Complex Gas Compositions JF - Sensors and Actuators B: Chemical N2 - The digitalization of industrial processes requires smart sensor systems. Photoacoustic spectroscopy is well suited for this purpose as it allows for small-sized and low-cost trace gas analysis. However, the method is susceptible to changes in measurement conditions and standard calibration routines often fail to correct for all changes. We therefore created a Digital Twin (DT) of a photoacoustic trace gas sensor for methane and evaluated it regarding variations in gas composition (CH4, N2, O2, CO2, H2O), temperature and pressure. With a mean absolute percentage error of 0.8 % the accuracy of the sensor after DT compensation significantly exceeds the 24 % achieved based on standard calibration in nitrogen. For the first time, we can fully analytically compute the photoacoustic signal under moderate ambient conditions with an error in the ppbV range by taking a holistic approach. Assuming knowledge of the underlying energy transfer processes, the model of this Digital Twin can be adapted to any microphone based photoacoustic sensor for monitoring any analyte species. KW - Digital Twin KW - Photoacoustic spectroscopy KW - Smart sensor KW - Acoustic resonance monitoring KW - CoNRad KW - Calibration-free method Y1 - 2023 U6 - https://doi.org/10.1016/j.snb.2022.133119 N1 - Preprint unter: https://doi.org/10.2139/ssrn.4215170 ; https://opus4.kobv.de/opus4-oth-regensburg/frontdoor/index/index/docId/5417 IS - 378 ER - TY - CHAP A1 - Pangerl, Jonas A1 - Wittmann, Elisabeth A1 - Weigl, Stefan A1 - Müller, Max A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Using a Modulated Quantum Cascade Laser for Photoacoustic Spectra Recording of Exhaled Acetone and Main Breath Components T2 - Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES) N2 - Photoacoustic spectra of main breath components together with acetone are presented demonstrating spectral linearity towards different concentrations and compositions. The acetone 3σ detection limit at 1209 cm−1 is 0.28 ppbV Y1 - 2023 U6 - https://doi.org/10.1364/AIS.2022.ATu3G.1 PB - Optica Publishing Group ER - TY - CHAP A1 - Escher, Lukas A1 - Rück, Thomas A1 - Jobst, Simon A1 - König, Martin A1 - Bierl, Rudolf T1 - Design and Characterization of a Low-Cost Photoacoustic Sensor for NO2 Using Lateral Illumination and Background Suppression T2 - Imaging and Applied Optics Congress 2022 (3D, AOA, COSI, ISA, pcAOP): 11–15 July 2022, Vancouver, British Columbia, Canada N2 - We introduce a low-cost photoacoustic NO2 sensor based on lateral LED illumination and optical background signal compensation. The 3σ limit of detection (LOD) was identified to be 24 ppbV. Y1 - 2022 SN - 978-1-957171-09-8 U6 - https://doi.org/10.1364/3D.2022.JTu2A.10 PB - Optica Publishing Group ER - TY - INPR A1 - Pangerl, Jonas A1 - Sukul, Pritam A1 - Rück, Thomas A1 - Escher, Lukas A1 - Miekisch, Wolfram A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Photoacoustic Trace-Analysis of Breath Isoprene and Acetone Via Interband- and Quantum Cascade Lasers N2 - This research presents two laser-based photoacoustic approaches for analyzing exhaled breath isoprene and acetone. The integration of a PTR-ToF-MS as a reference device ensured the reliability and accuracy of the PAS systems that is based on an ICL for isoprene and a QCL for acetone detection. The calibration yielded limits of detection of 26.9 ppbV and 1.7 ppbV, respectively, and corresponding normalized noise equivalent absorption coefficients (NNEAs) of 5.0E-9 Wcm-1Hz-0.5 and 4.9E-9 Wcm-1Hz-0.5. Laboratory as well as real breath sample measurements from alveolar breath revealed a robust system performance, with only one outlier within the static isoprene measurements. However, discrepancies emerged under dynamic breath sampling conditions, emphasizing the need for further optimization. Especially by knowing the dynamic nature and endogenous origin of exhaled isoprene our findings highlight the potential of breath analysis for non-invasive physio-metabolic and pathophysiological monitoring towards point-of-care devices. KW - photoacoustic spectroscopy KW - breath analysis/profiling KW - real-time mass spectroscopy KW - isoprene KW - acetone Y1 - 2024 U6 - https://doi.org/10.2139/ssrn.4834735 PB - Elsevier / SSRN ER - TY - JOUR A1 - Pangerl, Jonas A1 - Sukul, Pritam A1 - Rück, Thomas A1 - Escher, Lukas A1 - Miekisch, Wolfram A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Photoacoustic trace-analysis of breath isoprene and acetone via interband- and Quantum Cascade Lasers JF - Sensors and Actuators: B. Chemical N2 - This research presents two laser-based photoacoustic approaches for analyzing exhaled breath isoprene and acetone. The integration of a PTR-ToF-MS as a reference device ensured the reliability and accuracy of the photoacoustic systems that is based on an ICL for isoprene and a QCL for acetone detection. The calibration yielded limits of detection of 26.9 ppbV and 1.7 ppbV, respectively, and corresponding normalized noise equivalent absorption coefficients (NNEAs) of 5.0E-9 Wcm 1Hz 0.5 and 4.9E-9 Wcm 1Hz 0.5. Laboratory as well as real breath sample measurements from alveolar breath revealed a robust system performance, with only one outlier within the static isoprene measurements. However, discrepancies emerged under dynamic breath sampling conditions, emphasizing the need for further optimization. Especially by knowing the dynamic nature and endogenous origin of exhaled isoprene our findings highlight the potential of breath analysis for non-invasive physio-metabolic and pathophysiological monitoring towards point-of-care devices KW - Photoacoustic spectroscopy KW - Breath analysis/profiling KW - Real-time mass spectrometry KW - Isoprene KW - Acetone Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-77024 N1 - Corresponding author der OTH Regensburg: Jonas Pangerl VL - 424 PB - Elsevier ER - TY - CHAP A1 - Escher, Lukas A1 - Müller, Max A1 - Rück, Thomas A1 - Jobst, Simon A1 - Bierl, Rudolf T1 - Digitaler Zwilling photoakustischer Spurengassensoren zur Prozessüberwachung T2 - 16. Dresdner Sensor-Symposium 2022: Vorträge N2 - Stickstoffdioxid (NO2) wird hauptsächlich durch anthropogene Verbrennungsprozesse in Verkehr und Industrie in die Umgebungsluft eingebracht [1]. Die stark reaktive, oxidative Wirkung von NO2 kann bei Exposition mit höheren Konzentrationen Reizungen und allergische Reaktionen in den Atemwegen hervorrufen. Weiter führt NO2 zur Bildung von saurem Regen, Smog und Ozon (O3) die sich ebenso negativ auf die menschliche Gesundheit und Umwelt auswirken [2,3]. Aufgrund dieser Effekte wird die Spurengaskonzentration von NO2 in der Luft in Deutschland an ausgewählten, verkehrsreichen Orten gemessen. Y1 - 2022 SN - 978-3-9819376-7-1 U6 - https://doi.org/10.5162/16dss2022/3.3 PB - AMA (Association for Sensors + Measurement) ER - TY - JOUR A1 - Rück, Thomas A1 - Pangerl, Jonas A1 - Escher, Lukas A1 - Jobst, Simon A1 - Müller, Max A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Kinetic cooling in mid-infrared methane photoacoustic spectroscopy: A quantitative analysis via digital twin verification JF - Photoacoustics N2 - This study presents a detailed quantitative analysis of kinetic cooling in methane photoacoustic spectroscopy, leveraging the capabilities of a digital twin model. Using a quantum cascade laser tuned to 1210.01 cm⁻¹, we investigated the effects of varying nitrogen-oxygen matrix compositions on the photoacoustic signals of 15 ppmV methane. Notably, the photoacoustic signal amplitude decreased with increasing oxygen concentration, even falling below the background signal at oxygen levels higher than approximately 6 %V. This phenomenon was attributed to kinetic cooling, where thermal energy is extracted from the surrounding gas molecules rather than added, as validated by complex vector analysis using a previously published digital twin model. The model accurately reproduced complex signal patterns through simulations, providing insights into the underlying molecular mechanisms by quantifying individual collision contributions. These findings underscore the importance of digital twins in understanding the fundamentals of photoacoustic signal generation at the molecular level. Y1 - 2024 U6 - https://doi.org/10.1016/j.pacs.2024.100652 VL - 40 PB - Elsevier ER - TY - JOUR A1 - Jobst, Simon A1 - Recum, Patrick A1 - Écija-Arenas, Ángela A1 - Moser, Elisabeth A1 - Bierl, Rudolf A1 - Hirsch, Thomas T1 - Semi-Selective Array for the Classification of Purines with Surface Plasmon Resonance Imaging and Deep Learning Data Analysis JF - ACS sensors N2 - In process analytics or environmental monitoring, the real-time recording of the composition of complex samples over a long period of time presents a great challenge. Promising solutions are label-free techniques such as surface plasmon resonance (SPR) spectroscopy. They are, however, often limited due to poor reversibility of analyte binding. In this work, we introduce how SPR imaging in combination with a semi-selective functional surface and smart data analysis can identify small and chemically similar molecules. Our sensor uses individual functional spots made from different ratios of graphene oxide and reduced graphene oxide, which generate a unique signal pattern depending on the analyte due to different binding affinities. These patterns allow four purine bases to be distinguished after classification using a convolutional neural network (CNN) at concentrations as low as 50 μM. The validation and test set classification accuracies were constant across multiple measurements on multiple sensors using a standard CNN, which promises to serve as a future method for developing online sensors in complex mixtures. KW - surface plasmon resonance imaging KW - functional surface KW - graphene oxide KW - reduced graphene oxide KW - 2D materials KW - pattern recognition KW - small-molecule sensing Y1 - 2023 U6 - https://doi.org/10.1021/acssensors.3c01114 VL - 8 IS - 9 SP - 3530 EP - 3537 PB - American Chemical Society ER - TY - CHAP A1 - Hausler, Peter A1 - Wunderlich, Lukas A1 - Fischer, Johannes A1 - Pfab, Christina A1 - Heckscher, Simon A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Surface plasmon resonance imaging for detection of drug metabolites in water T2 - Proceedings of SPIE, Optical Sensors 2019, 1 - 4 April 2019, Prague, Czech Republic N2 - The analysis of surface water, groundwater, drinking water as well as sewage is important to get information about the contamination of the water cycle. Currently, these time-consuming investigations require special equipment, like for example hyphenated mass spectrometry. Surface plasmon resonance (SPR) is a faster alternative as it is highly sensitive to changes in the dielectric medium next to a thin metal layer and makes it a quasi-universal detector. Therefore, and due to the labelfree nature, SPR is a widely used sensing tool for real‐time monitoring of molecular interactions of various analytes. SPR imaging (SPRi) has several advantages to standard surface plasmon resonance, as it allows to observe many analytes in parallel as well as the integration of referencing technologies. However, the homogenous illumination of a large area (several millimeters) with a small light source is challenging and demands new approaches. Allopurinol, a drug used to lower the blood concentration of urate and hence decrease the affection of gout, gets metabolized to oxipurinol in the body and dropped out almost entirely by urinary excretion. After wastewater treatment, concentrations of oxipurinol up to 21.7 μg•L-1 are detected. Further tracking of oxipurinol in the urban water cycle showed its presence in rivers and streams or even in groundwater. Therefore, the high biological stability of oxipurinol allows this molecule to be used as a marker for domestic wastewater in the environment. For the detection of oxipurinol by SPR graphene was used as receptive layer, as the analyte can bind via π-stacking to this surface. An SPRi technique was developed and compared to conventional SPR system for the detection of oxipurinol. Y1 - 2019 U6 - https://doi.org/10.1117/12.2522324 SN - 0277-786X VL - Vol. 11028 ER - TY - CHAP A1 - Hausler, Peter A1 - Roth, Carina A1 - Aumer, F. A1 - Vitzthumecker, Thomas A1 - Genslein, Christa A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Miniaturisiertes Sensorsystem zur Oberflächenplasmonenresonanzspektroskopie T2 - 118. Jahrestagung der deutschen Gesellschaft für angewandte Optik (DGaO), 6.-10. Juni 2017, Dresden N2 - Die Oberflächenplasmonenresonanzspektroskopie (SPR) wird aufgrund ihrer Vorzüge der zerstörungs- und markierungsfreien Messung, sowie der hohen Sensitivität sehr erfolgreich im Labormaßstab eingesetzt. Aufgrund der hohen Kosten geschieht dies bislang hauptsächlich in der Bioanalytik und dem Wirkstoffscreening. Gezeigt wird ein Ansatz, mit dem diese Technologie auf ein ultrakompaktes, kostengünstiges Sensorsystem übertragen wird, welches in der Lage ist, hoch-sensitiv Änderungen im Brechungsindex von 10-6 Einheiten (RIU) zu detektieren. Für Wasser bewirkt eine Temperaturschwankung von 1 K bereits eine Änderung von 1 mRIU. Daher wird durch ein integriertes Referenzsystem, sowie die Miniaturisierung erreicht, dass das System gegenüber Temperaturschwankungen, weitestgehend stabil ist. In dem MOEMS wird anstatt der konventionellen 1-Punkt bzw. 2-Punkt Messung ein bildgebendes Verfahren angewendet. Die Sensorfläche von 15 x 15 mm wird dabei mit einem handelsüblichen 4 Mio. Pixel CMOS Sensor ausgewertet. Um verlässliche Datenpunkte zu erhalten benötigt man eine Fläche von 10 x 10 Pixel. Demzufolge können auf dem Sensor theoretisch bis zu 40.000 Sensorspots parallel ausgewertet werden. KW - Messtechnik KW - Optische Systeme KW - Spektroskopie Y1 - 2017 ER - TY - CHAP A1 - Hausler, Peter A1 - Genslein, Christa A1 - Roth, Carina A1 - Vitzthumecker, Thomas A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Miniaturized Surface Plasmon Resonance based Sensor System T2 - Proceedings of the 6th International Conference on Photonics, Optics and Laser Technology - PHOTOPTICS, Funchal, Madeira, Portugal N2 - We describe the miniaturization of the Surface Plasmon Resonance (SPR) technology which mainly finds its applications in pharmaceutical screening and biotechnology so far. SPR spectroscopy is a label-free, non-destructive and highly sensitive measurement principle detecting changes in the refractive index in striking distance to a gold surface. A transfer of this technology to a miniaturized sensor will broaden the range of possible applications. A promising feature which is included in the miniaturized system is the angle-dependent recording of the SPR signals without moving parts. Commercial SPR assays are mainly working with a small number of sensing spots. In contrast, the SPR imaging system shown here will allow to use an array of many sensing spots. In combination with chemical receptors designed as an artificial nose, the simultaneous detection of many analytes is envisioned for future applications. KW - Surface Plasmon Resonance Spectroscopy KW - Sensor KW - SPR-imaging KW - Miniaturization KW - Micro-Opto-Electro-Mechanical Systems Y1 - 2018 SN - 978-989-758-286-8 U6 - https://doi.org/10.5220/0006555400630066 SP - 63 EP - 66 PB - SciTePress ER - TY - JOUR A1 - Genslein, Christa A1 - Hausler, Peter A1 - Kirchner, Eva-Maria A1 - Bierl, Rudolf A1 - Baeumner, Antje J. A1 - Hirsch, Thomas T1 - Graphene-enhanced plasmonic nanohole arrays for environmental sensing in aqueous samples JF - Beilstein Journal of Nanotechnology N2 - The label-free nature of surface plasmon resonance techniques (SPR) enables a fast, specific, and sensitive analysis of molecular interactions. However, detection of highly diluted concentrations and small molecules is still challenging. It is shown here that in contrast to continuous gold films, gold nanohole arrays can significantly improve the performance of SPR devices in angle-dependent measurement mode, as a signal amplification arises from localized surface plasmons at the nanostructures. This leads consequently to an increased sensing capability of molecules bound to the nanohole array surface. Furthermore, a reduced graphene oxide (rGO) sensor surface was layered over the nanohole array. Reduced graphene oxide is a 2D nanomaterial consisting of sp2-hybridized carbon atoms and is an attractive receptor surface for SPR as it omits any bulk phase and therefore allows fast response times. In fact, it was found that nanohole arrays demonstrated a higher shift in the resonance angle of 250–380% compared to a continuous gold film. At the same time the nanohole array structure as characterized by its diameter-to-periodicity ratio had minimal influence on the binding capacity of the sensor surface. As a simple and environmentally highly relevant model, binding of the plasticizer diethyl phthalate (DEP) via π-stacking was monitored on the rGO gold nanohole array realizing a limit of detection of as low as 20 nM. The concentration-dependent signal change was studied with the best performing rGO-modified nanohole arrays. Compared to continuous gold films a diameter-to-periodicity ratio (D/P) of 0.43 lead to a 12-fold signal enhancement. Finally, the effect of environmental waters on the sensor was evaluated using samples from sea, lake and river waters spiked with analytically relevant amounts of DEP during which significant changes in the SPR signal are observed. It is expected that this concept can be successfully transferred to enhance the sensitivity in SPR sensors. KW - diethyl phthalate KW - environmental sensing KW - nanohole array KW - nanosphere lithography KW - surface plasmon resonance Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:355-epub-398623 IS - 7 SP - 1564 EP - 1573 ER - TY - CHAP A1 - Hausler, Peter A1 - Genslein, Christa A1 - Roth, Carina A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Mikro-Opto-Elektro-Mechanisches Sensorsystem zur Oberflächenplasmonenresonanzspektroskopie T2 - MikroSystemTechnik Kongress 2017 : MEMS, Mikroelektronik, Systeme 23.-25. Oktober 2017 in München N2 - Gezeigt wird die Miniaturisierung eines Messsystems für Oberflächenplasmonenresonanzspektroskopie (SPR), einer markierungs-, sowie zerstörungsfreien als auch hoch sensitiven Technologie. Aufgrund der hohen Kosten klassischer SPR-Geräte wird sie bisher jedoch vornehmlich in der Bio- und Medizintechnik eingesetzt. Das Messprinzip ermöglicht die Erfassung von Brechungsindexänderungen nahe einer Oberfläche. Der Transfer dieser Technologie von Laborgeräten hin zu einem miniaturisierten Sensorsystem senkt die Kosten, macht das System robuster und ermöglicht so ein wesentlich breiteres Anwendungsspektrum. Ein sehr vielversprechendes Merkmal des hier vorgestellten Systems ist die Möglichkeit den SPR-Effekt winkelabhängig zur Lichtquelle ohne bewegliche Bauteile zu verfolgen. The miniaturization of Surface Plasmon Resonance (SPR) technology, which mainly finds its applications in pharmaceutical screening and biotechnology so far, is described. SPR spectroscopy is a label-free, non destructive and highly sensitive measurement principle which is capable of detecting changes in the refractive index in striking distance to a gold surface. A transfer of this technology to a miniaturized sensor will broaden the range of possible applications. A promising feature which is included in the miniaturized system is the angle-dependent recording of the SPR signals without moving parts. KW - Bewegungselement KW - Biotechnik KW - Brechungsindex KW - Goldoberfläche KW - Laborgerät KW - Lichtquelle KW - Medizintechnik KW - Messprinzip KW - Messsystem KW - Miniaturisierung KW - Oberflächenplasmon KW - Oberflächenplasmonenresonanzspektroskopie KW - pharmazeutisches Screening KW - Sensorsystem KW - Spektroskopie Y1 - 2017 SN - 978-3-8007-4491-6 IS - CD-ROM SP - 645 EP - 647 PB - VDE-Verlag CY - Berlin ER - TY - CHAP A1 - Genslein, Christa A1 - Hauser, Peter A1 - Kirchner, Eva-Maria A1 - Bierl, Rudolf A1 - Baeumner, Antje J. A1 - Hirsch, Thomas T1 - Detection of small molecules with surface plasmon resonance by synergistic plasmonic effects of nanostructured surfaces and graphene T2 - SPIE Proceedings, Plasmonics in Biology and Medicine XIV, 2017, San Francisco, California N2 - Surface plasmon resonance depends on the dielectric medium at the vicinity and makes it a quasi-universal detector. Therefore, and due to the label-free nature, SPR is a widely used sensing tool for real‐time monitoring molecular interactions of various analytes. However, detection of highly diluted analytes and small molecules (< 400 Da) is still challenging. Gold nanohole arrays provide plasmonic hotspots with improved surface sensitivity and 2D carbon nanomaterials enable binding near the surface. Both effects together are promising in the development of SPR sensors for the efficient determination of small molecules. Graphene is known for efficient binding of molecules with delocalized aromatic π-systems. Additionally, the electromagnetic field is locally enhanced and modulated by the interaction of graphene photonics with the plasmonics of metal nanostructures. The advantages of chemical vapor deposition (CVD) graphene over reduced graphene oxide (rGO) is illustrated by a proof of concept study. In comparison to substrates consisting of a continuous film the surface sensitivity is enhanced for a nanohole arrays and further improved for CVD graphene functionalization in contrast to rGO. The feasibility of the sensor was demonstrated for the detection of adenine down to a concentration of 0.9 μM. Y1 - 2017 U6 - https://doi.org/10.1117/12.2252256 VL - 10080 IS - 1008001F ER - TY - CHAP A1 - Hausler, Peter A1 - Holler, Sven A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - High integrated miniaturized sensor based on Surface Plasmon Resonance T2 - International Biosensor Conference, 11th Workshop on Biosensors & Bioanalytical Microtechniques in Environmental, Food & Clinical Analysis, BBMEC 11, 26.-30. September 2015, Regensburg, Germany Y1 - 2015 ER - TY - CHAP A1 - Hausler, Peter A1 - Holler, Sven A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Miniaturisierte Oberflächenplasmonenresonanz Sensorplattform T2 - MEMS, Mikroelektronik, Systeme, MikroSystemTechnik Kongress 2015, 26.- 28. Oktober 2015, Karlsruhe, proceedings Y1 - 2015 SN - 978-3-8007-4100-7 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Appelhans, Marie-Luise A1 - Kampmann, Matthias A1 - Mottok, Jürgen A1 - Riederer, Michael A1 - Nagl, Klaus A1 - Steffens, Oliver A1 - Dünnweber, Jan A1 - Wildgruber, Markus A1 - Roth, Julius A1 - Stadler, Timo A1 - Palm, Christoph A1 - Weiß, Martin Georg A1 - Rochholz, Sandra A1 - Bierl, Rudolf A1 - Gschossmann, Andreas A1 - Haug, Sonja A1 - Schmidbauer, Simon A1 - Koch, Anna A1 - Westner, Markus A1 - Bary, Benedikt von A1 - Ellermeier, Andreas A1 - Vögele, Daniel A1 - Maiwald, Frederik A1 - Hierl, Stefan A1 - Schlamp, Matthias A1 - Ehrlich, Ingo A1 - Siegl, Marco A1 - Hüntelmann, Sven A1 - Wildfeuer, Matthias A1 - Brückl, Oliver A1 - Sterner, Michael A1 - Hofrichter, Andreas A1 - Eckert, Fabian A1 - Bauer, Franz A1 - Dawoud, Belal A1 - Rabl, Hans-Peter A1 - Gamisch, Bernd A1 - Schmidt, Ottfried A1 - Heberl, Michael A1 - Thema, Martin A1 - Mayer, Ulrike A1 - Eller, Johannes A1 - Sippenauer, Thomas A1 - Adelt, Christian A1 - Haslbeck, Matthias A1 - Vogl, Bettina A1 - Mauerer, Wolfgang A1 - Ramsauer, Ralf A1 - Lohmann, Daniel A1 - Sax, Irmengard A1 - Gabor, Thomas A1 - Feld, Sebastian A1 - Linnhoff-Popien, Claudia A1 - Ławrowski, Robert Damian A1 - Langer, Christoph A1 - Schreiner, Rupert A1 - Sellmair, Josef ED - Baier, Wolfgang T1 - Forschung 2019 BT - Thema: Künstliche Intelligenz N2 - Bericht mit Forschungsprojekten aus verschiedenen Bereichen der OTH Regensburg mit dem Schwerpunktthema "Künstliche Intelligenz" und einem Gespräch zur "Medizin der Zukunft" T3 - Forschungsberichte der OTH Regensburg - 2019 KW - Forschung KW - Forschungsbericht KW - Künstliche Intelligenz Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-7890 SN - 978-3-9818209-7-3 CY - Regensburg ER - TY - JOUR A1 - Weber, Karsten A1 - Dendorfer, Sebastian A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Schratzenstaller, Thomas A1 - Haug, Sonja A1 - Mohr, Christa A1 - Kiesl, Hans A1 - Drechsler, Jörg A1 - Westner, Markus A1 - Kobus, Jörn A1 - Schubert, Martin J. W. A1 - Zenger, Stefan A1 - Pietsch, Alexander A1 - Weiß, Josef A1 - Hinterseer, Sebastian A1 - Schieck, Roland A1 - Scherzinger, Stefanie A1 - Klettke, Meike A1 - Ringlstetter, Andreas A1 - Störl, Uta A1 - Bissyandé, Tegawendé F. A1 - Seeburger, Achim A1 - Schindler, Timo A1 - Ramsauer, Ralf A1 - Kiszka, Jan A1 - Kölbl, Andreas A1 - Lohmann, Daniel A1 - Mauerer, Wolfgang A1 - Maier, Johannes A1 - Scorna, Ulrike A1 - Palm, Christoph A1 - Soska, Alexander A1 - Mottok, Jürgen A1 - Ellermeier, Andreas A1 - Vögele, Daniel A1 - Hierl, Stefan A1 - Briem, Ulrich A1 - Buschmann, Knut A1 - Ehrlich, Ingo A1 - Pongratz, Christian A1 - Pielmeier, Benjamin A1 - Tyroller, Quirin A1 - Monkman, Gareth J. A1 - Gut, Franz A1 - Roth, Carina A1 - Hausler, Peter A1 - Bierl, Rudolf A1 - Prommesberger, Christian A1 - Ławrowski, Robert Damian A1 - Langer, Christoph A1 - Schreiner, Rupert A1 - Huang, Yifeng A1 - She, Juncong A1 - Ottl, Andreas A1 - Rieger, Walter A1 - Kraml, Agnes A1 - Poxleitner, Thomas A1 - Hofer, Simon A1 - Heisterkamp, Benjamin A1 - Lerch, Maximilian A1 - Sammer, Nike A1 - Golde, Olivia A1 - Wellnitz, Felix A1 - Schmid, Sandra A1 - Muntschick, Claudia A1 - Kusterle, Wolfgang A1 - Paric, Ivan A1 - Brückl, Oliver A1 - Haslbeck, Matthias A1 - Schmidt, Ottfried A1 - Schwanzer, Peter A1 - Rabl, Hans-Peter A1 - Sterner, Michael A1 - Bauer, Franz A1 - Steinmann, Sven A1 - Eckert, Fabian A1 - Hofrichter, Andreas ED - Baier, Wolfgang T1 - Forschungsbericht 2017 T3 - Forschungsberichte der OTH Regensburg - 2017 KW - Forschung KW - Forschungsbericht Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-13835 SN - 978-3-9818209-3-5 CY - Regensburg ER - TY - JOUR A1 - Pangerl, Jonas A1 - Moser, Elisabeth A1 - Müller, Max A1 - Weigl, Stefan A1 - Jobst, Simon A1 - Rück, Thomas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - A sub-ppbv-level Acetone and Ethanol Quantum Cascade Laser Based Photoacoustic Sensor– Characterization and Multi-Component Spectra Recording in Synthetic Breath JF - Photoacoustics N2 - Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8263 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbv in terms of ethanol and 250 pptv regarding acetone, our system is among the best performing presented so far. KW - Acetone KW - Breath analysis KW - Photoacoustic spectroscopy KW - Quantum cascade laser KW - Spectral simulation Y1 - 2023 U6 - https://doi.org/10.1016/j.pacs.2023.100473 SN - 2213-5979 N1 - Corresponding author: Jonas Pangerl VL - 30 SP - 1 EP - 12 PB - Elsevier ER - TY - PAT A1 - Olbrich, Florian A1 - Pongratz, Christian A1 - Bierl, Rudolf A1 - Ehrlich, Ingo T1 - Method and System for Evaluating a Structural Integrity of an Aerial Vehicle T2 - Europäisches Patentblatt (09.12.2020) zur Anmeldung: OTH Regensburg, Anmeldenummer: 19179054.2, Patentnummer 1001/3748327, Veröffentlichungsnummer: 3 748 327 Y1 - 2020 SP - 395 EP - 396 ER - TY - CHAP A1 - Hausler, Peter A1 - Fischer, Johannes A1 - Wunderlich, Lukas A1 - Recum, Patrick A1 - Peller, Sebastian A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Miniaturisierte Sensoren basierend auf Oberflächenplasmonenresonanz, Chancen und Herausforderungen T2 - DGaO-Proceedings 2021 N2 - Derzeit gibt es zahlreiche Bereiche, wie Umwelt Monitoring und zivile Infrastruktur in denen geeignete Sensoren für die Überwachung der Systeme fehlen. SPR-basierte Sensoren haben das Potential diese Lücke zu schließen. Um für den Einsatz in der Umwelt tauglich zu werden, müssen die Sensoren noch robuster werden. Hier wird eine mögliche Lösung gezeigt. Y1 - 2021 UR - https://www.dgao-proceedings.de/download/122/122_a21.pdf PB - Dt. Gesellschaft für angewandte Optik CY - Erlangen-Nürnberg ER -