TY - JOUR A1 - Frazzica, Andrea A1 - Palomba, Valeria A1 - Dawoud, Belal A1 - Gullì, Giuseppe A1 - Brancato, Vincenza A1 - Sapienza, Alessio A1 - Vasta, Salvatore A1 - Freni, Angelo A1 - Costa, Fabio A1 - Restuccia, Giovanni T1 - Design, realization and testing of an adsorption refrigerator based on activated carbon/ethanol working pair JF - Applied Energy N2 - In the present paper design, realization and testing of a novel small scale adsorption refrigerator prototype based on activated carbon/ethanol working pair is described. Firstly, experimental activity has been carried out for identification of the best performing activated carbon available on the market, through the evaluation of the achievable thermodynamic performance both under air conditioning and refrigeration conditions. Once identified the best performing activated carbon, the design of the adsorber was developed by experimental dynamic performance analysis, carried out by means of the Gravimetric-Large Temperature Jump (G-LTJ) apparatus available at CNR ITAE lab. Finally, the whole 0.5 kW refrigerator prototype was designed and built. First experimental results both under reference air conditioning and refrigeration cycles have been reported, to check the achievable performance. High Specific Cooling Powers (SCPs), 95 W/kg and 50 W/kg, for air conditioning and refrigeration respectively, were obtained, while the COP ranged between 0.09 and 0.11, thus showing an improvement of the current state of the art. (C) 2016 Elsevier Ltd. All rights reserved. KW - Activated carbon KW - ADSORBENTS KW - adsorption KW - Ammonia KW - CARBON KW - CHILLER KW - COOLING SYSTEMS KW - Corrosion KW - DRIVEN KW - Ethanol KW - ETHANOL ADSORPTION KW - PERFORMANCE KW - Refrigeration KW - waste heat Y1 - 2016 U6 - https://doi.org/10.1016/j.apenergy.2016.04.080 VL - 174 SP - 15 EP - 24 PB - Elsevier ER - TY - JOUR A1 - Palomba, Valeria A1 - Dawoud, Belal A1 - Sapienza, Alessio A1 - Vasta, Salvatore A1 - Frazzica, Andrea T1 - On the impact of different management strategies on the performance of a two-bed activated carbon/ethanol refrigerator: An experimental study JF - Energy conversion and management N2 - In the present work, an experimental study on a lab-scale adsorption refrigerator, based on activated carbon/ethanol working pair is reported. An extensive testing campaign has been carried out at the CNR ITAE laboratory, with multiple aims. First, the performance has been evaluated in terms of both COP and Specific Cooling Power (SCP), under different boundary conditions, including both air conditioning and refrigeration applications. Attractive SCPs, up to 180 W/kg and 70 W/kg for air conditioning and refrigeration, respectively, were measured. Under the same conditions, COP between 0.17 and 0.08 were obtained. In addition, different management strategies, namely, heat recovery between adsorbers and re-allocation of phase durations, were evaluated to identify their influence on the system. Both strategies confirmed the possibility of increasing COP and SCP up to 40% and 25%, respectively. Moreover, a design analysis based on the experimental results has been carried out, to suggest possible improvements of the system. The obtained results demonstrated the possibility of employing a non-toxic refrigerant like ethanol reaching performance comparable with other harmful refrigerants like ammonia and methanol. (C) 2017 Elsevier Ltd. All rights reserved. KW - Activated carbon KW - Adsorption refrigeration KW - ADSORPTION REFRIGERATOR KW - CARBON KW - Corrosion KW - DRIVEN KW - DYNAMICS KW - Ethanol KW - ETHANOL ADSORPTION KW - experimental testing KW - HEAT-RECOVERY KW - IMPROVEMENT KW - Management strategy KW - MASS KW - waste heat Y1 - 2017 U6 - https://doi.org/10.1016/j.enconman.2017.03.055 VL - 142 SP - 322 EP - 333 PB - Elsevier ER - TY - JOUR A1 - Proverbio, Edoardo A1 - Calabrese, Luigi A1 - Capri, Angela A1 - Bonaccorsi, Lucio Maria A1 - Dawoud, Belal A1 - Frazzica, Andrea T1 - Susceptibility to corrosion of aluminium alloy components in ethanol adsorption chiller JF - Renewable energy N2 - Methanol, and more recently ethanol, have been deeply employed as adsorbate phase (refrigerant) in adsorption chiller and heat pump applications (e.g. refrigerator adsorption ice maker). The use of anhydrous alcohols however can cause several problems related to the corrosiveness of such molecules towards light alloys (from titanium to aluminium). The problem was already highlighted in bio-fuel technology where bio-ethanol was considered as a promise alternative to fossil hydrocarbons. Water content was observed as one of the main factors influencing corrosion rate. In the present works several accelerated corrosion tests on 6061 Aluminium alloy have been carried out in autoclave in a temperature range from 110 to 135 degrees C with different ethanol to aluminium mass ratio. Highly exothermic reactions related to aluminium oxidation, coupled to hydrogen evolution, have been recorded. The main drawback of hydrogen evolution is the formation of a stagnant layer over the heat exchangers surface, which can limit the ethanol vapour diffusion, thus reducing adsorption condensation rate. (C) 2016 Elsevier Ltd. All rights reserved. KW - Aluminium KW - Corrosion KW - CRACKING KW - design KW - Ethanol KW - FUEL BLENDS KW - PAIR KW - RECOVERY KW - Refrigerating systems KW - REFRIGERATOR KW - TITANIUM Y1 - 2017 U6 - https://doi.org/10.1016/j.renene.2016.08.042 VL - 110 SP - 174 EP - 179 PB - Elsevier ER - TY - JOUR A1 - Frazzica, Andrea A1 - Brancato, Vincenza A1 - Dawoud, Belal T1 - Unified Methodology to Identify the Potential Application of Seasonal Sorption Storage Technology JF - Energies N2 - In this study, the definition of a new methodology for a preliminary evaluation of the working boundary conditions under which a seasonal thermal energy storage (STES) system operates is described. The approach starts by considering the building features as well as the reference heating system in terms of solar thermal collectors’ technology, ambient heat sinks/source, and space heating distribution systems employed. Furthermore, it is based on a deep climatic analysis of the place where the STES needs to be installed, to identify both winter and summer operating conditions. In particular, the STES energy density is evaluated considering different space heating demands covered by the STES (ranging from 10% up to 60%). The obtained results demonstrate that this approach allows for the careful estimation of the achievable STES density, which is varies significantly both with the space heating coverage guaranteed by the STES as well as with the ambient heat source/sink that is employed in the system. This confirms the need for careful preliminary analysis to avoid the overestimation of the STES material volume. The proposed approach was then applied for different climatic conditions (e.g., Germany and Sweden) and the volume of one of the most attractive composite sorbent materials reported in the literature, i.e., multi-wall carbon nanotubes (MWCNT)-LiCl, using water as the working fluid, needed for covering the variable space heating demand in a Nearly Zero Energy Building (NZEB) was calculated. In the case of Swedish buildings, it ranges from about 3.5 m3 when 10% of the space heating demand is provided by the STES, up to 11.1 m3 when 30% of the space heating demand is provided by the STES. KW - seasonal thermal storage KW - composite sorbents KW - operating conditions Y1 - 2020 U6 - https://doi.org/10.3390/en13051037 VL - 13 IS - 5 SP - 1 EP - 17 PB - MPDI CY - Basel ER - TY - BOOK A1 - Freni, Angelo A1 - Dawoud, Belal A1 - Bonaccorsi, Lucio Maria A1 - Chmielewski, Stefanie A1 - Frazzica, Andrea A1 - Calabrese, Luigi A1 - Restuccia, Giovanni T1 - Characterization of Zeolite-Based Coatings for Adsorption Heat Pumps N2 - This book proposes a radically new approach for characterizing thermophysical and mechanical properties of zeolite-based adsorbent coatings for Adsorptive Heat Transformers (AHT). It presents a developed standard protocol for the complete characterization of advanced coated adsorbers. Providing an in-depth analysis of the different procedures necessary for evaluating the performance of adsorbers, it also presents an analysis of their stability under the hydrothermal and mechanical stresses during their entire life cycle. Adsorptive Heat Transformers (AHT), especially adsorption chillers and heat pumps, are considered to be promising technologies to increase thermal energy efficiency. Nevertheless, an overall increase in performance of this apparatus is necessary for them to be considered a mature technology to be used commercially. Development of innovative coated adsorbers can be perceived as a key issue for the enhancement of AHT technology. This procedure relies on the deposition, either by means of a binder or by direct crystallization, of the adsorbent material over a metallic heat exchanger, aiming at the improvement of the heat transfer between the external heat source and the adsorbent itself. This book offers a valuable resource to those working on the development of novel adsorbent materials and advanced adsorbent beds for heating and cooling applications. It is also intended for researchers interested in renewable energy and energy efficiency. KW - AHT KW - Adsorbent Coatings KW - Adsorption KW - Adsorptive Heat Transformers KW - Stability Verification KW - Zeolite-based Adsorbent Coatings KW - Zeolite-coated Heat Pumps Y1 - 2015 U6 - https://doi.org/10.1007/978-3-319-09327-7 PB - Springer CY - Berlin ER - TY - JOUR A1 - Freni, Angelo A1 - Frazzica, Andrea A1 - Dawoud, Belal A1 - Chmielewski, Stefanie A1 - Calabrese, Luigi A1 - Bonaccorsi, Lucio Maria T1 - Adsorbent coatings for heat pumping applications: Verification of hydrothermal and mechanical stabilities JF - Applied Thermal Engineering N2 - This paper presents novel experimental methods for verification of both hydrothermal and mechanical stabilities of adsorbent coatings. Experiments have been carried out on zeolite-based coatings over aluminum substrates, prepared by a dip-coating technique developed at CNR-ITAE. Hydrothermal aging of several adsorbent coatings is ongoing. Adsorption and structural stability of some samples under test was successfully verified after 35000 aging cycles by isobars measurement and XRD analysis. Mechanical properties of coatings have been evaluated by applying different typologies of static and dynamic mechanical stresses. Results obtained have been compared with those achieved by subjecting adsorbent coatings prepared by Mitsubishi Plastic Incorporation (MPI) to the same characterization protocol. The comparison between the two types of coating returned that MPI coatings posses similar thermal stability and better mechanical strength than CNR-ITAE coatings. KW - Adsorbent coating KW - Adsorption heat pump KW - Hydrothermal stability KW - Mechanical stability Y1 - 2013 U6 - https://doi.org/10.1016/j.applthermaleng.2011.07.010 VL - 50 IS - 2 SP - 1658 EP - 1663 PB - Elsevier ER - TY - JOUR A1 - Frazzica, Andrea A1 - Palomba, Valeria A1 - Dawoud, Belal T1 - Thermodynamic Performance of Adsorption Working Pairs for Low-Temperature Waste Heat Upgrading in Industrial Applications JF - Applied Sciences N2 - The present work aims at the thermodynamic analysis of different working pairs in adsorption heat transformers (AdHT) for low-temperature waste heat upgrade in industrial processes. Two different AdHT configurations have been simulated, namely with and without heat recovery between the adsorbent beds. Ten working pairs, employing different adsorbent materials and four different refrigerants, have been compared at varying working boundary conditions. The effects of heat recovery and the presence of a temperature gradient for heat transfer between sinks/sources and the AdHT components have been analyzed. The achieved results demonstrate the possibility of increasing the overall performance when internal heat recovery is implemented. They also highlight the relevant role played by the existing temperature gradient between heat transfer fluids and components, that strongly affect the real operating cycle of the AdHT and thus its expected performance. Both extremely low, i.e., 40-50 degrees C, and low (i.e., 80 degrees C) waste heat source temperatures were investigated at variable ambient temperatures, evaluating the achievable COP and specific energy. The main results demonstrate that optimal performance can be achieved when 40-50 K of temperature difference between waste heat source and ambient temperature are guaranteed. Furthermore, composite sorbents demonstrated to be the most promising adsorbent materials for this application, given their high sorption capacity compared to pure adsorbents, which is reflected in much higher achievable specific energy. KW - adsorption KW - efficiency KW - heat transformer KW - heat upgrading KW - waste heat KW - working pairs Y1 - 2021 U6 - https://doi.org/10.3390/app11083389 VL - 11 IS - 8 PB - MDPI ER - TY - JOUR A1 - Palomba, Valeria A1 - Nowak, Sebastian A1 - Dawoud, Belal A1 - Frazzica, Andrea T1 - Dynamic modelling of Adsorption systems: a comprehensive calibrated dataset for heat pump and storage applications JF - Journal of energy storage N2 - The growing efforts for the development of clean and efficient energy systems require the use of a multi-disciplinary approach and the integration of multiple generation appliances. Among the fields that can be considered enabling technologies, adsorption systems for air conditioning and thermal energy storages, are constantly increasing their maturity. However, for a proper design and integration of such systems, there is the need for a simulation framework that is reliable and computationally convenient. In the present paper, the implementation of a dynamic model for adsorption systems is presented, which includes different components (adsorber, phase changer, sorption materials) and is structured as a library. Modelica language and the commercial software Dymola (R) are used for the analysis. Data for different heat exchangers and working pairs are calibrated using experimental results and the calibrated model is subsequently used for the design of an adsorber based on a plate heat exchanger for thermal energy storage applications. The results proved that the model is fast and can reproduce experimental results with good accuracy, thus being a useful tool for the design and optimization of the different components of sorption systems. KW - CHILLERS KW - DIFFUSION KW - ETHANOL ADSORPTION KW - Optimization KW - PERFORMANCE KW - SCALE KW - simulation KW - THERMAL-ENERGY STORAGE KW - TRANSFORMATION KW - WATER-ADSORPTION Y1 - 2021 U6 - https://doi.org/10.1016/j.est.2020.102148 VL - 33 PB - Elsevier ER - TY - JOUR A1 - Mikhaeil, Makram A1 - Nowak, Sebastian A1 - Palomba, Valeria A1 - Frazzica, Andrea A1 - Gaderer, Matthias A1 - Dawoud, Belal T1 - Experimental and analytical investigation of applying an asymmetric plate heat exchanger as an evaporator in a thermally driven adsorption appliance JF - Applied Thermal Engineering N2 - This communication presents an experimental and analytical study on the evaporation mechanism in a closed-structured asymmetric plate heat exchanger (PHE) employed as a stagnant water evaporator for the application in an adsorption heat transformation appliance. To this aim, an experimental unit is constructed, which comprises two identical PHEs, one acting as an vaporator/condenser and the second, as an adsorber/desorber. Two endoscopes are mounted inside the investigated evaporator to visualize the evaporation mechanism when performing adsorption-evaporation processes under different boundary conditions. It turned out that the evaporation mechanism is a partially covered, thin film evaporation. A heat transfer analysis is performed to evaluate the heat transfer coefficient of the thin film evaporation () inside the investigated evaporator, resulting in -values between 1330 and 160 [W∙m−2∙K−1] over the investigated adsorption-evaporation time. Correlating the obtained () to the film thickness and the wetted area results in -values between 0.34 and 0.78 [mm] and wetted to total area ratios of 0.78 to 0.16. Besides, an analytical model has been developed and introduced to correlate the overall evaporator heat transfer coefficient with the adsorption potential and the time rate of change of the water uptake. KW - Adsorption-evaporation KW - Evaporator KW - Plate heat exchanger KW - Thin film evaporation Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-61115 N1 - Corresponding author: Belal Dawoud IS - 228 PB - Elsevier ER -