TY - GEN A1 - Auer, Simon A1 - Krutsch, Werner A1 - Renkawitz, Tobias A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Effect of mental demand on leg loading in highly dynamic motion T2 - AnyBody online Webinar, Oct 2020 N2 - Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury. Y1 - 2020 ER - TY - JOUR A1 - Auer, Simon A1 - Krutsch, Werner A1 - Renkawitz, Tobias A1 - Kubowitsch, Simone A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Kognitiver Stress führt zu unphysiologisch erhöhten Kniebelastungen im Profifußball JF - Sports Orthopaedics and Traumatology Y1 - 2020 U6 - https://doi.org/10.1016/j.orthtr.2020.04.122 VL - 36 IS - 2 SP - 202 EP - 203 PB - Elsevier ER - TY - CHAP A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Rasmussen, John A1 - Verkerke, Gijsbertus Jacob A1 - Dendorfer, Sebastian T1 - The influence of cognitive stress on muscle activation and spinal disc load T2 - European Society of Biomechanics meeting 2019, Vienna, Austria Y1 - 2019 UR - https://owncloud.tuwien.ac.at/index.php/s/dovqqcj02VeZHze ER - TY - GEN A1 - Aurbach, Maximilian A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - The impact of the hill type muscle model on the glenohumeral joint reaction force T2 - 16th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) 2019, New York City, USA Y1 - 2019 ER - TY - CHAP A1 - Aurbach, Maximilian A1 - Wagner, Kilian A1 - Süß, Franz A1 - Dendorfer, Sebastian ED - Badnjevic, Almir T1 - Implementation and Validation of Human Kinematics Measured Using IMUs for Musculoskeletal Simulations by the Evaluation of Joint Reaction Forces T2 - CMBEBIH 2017, Proceedings of the International Conference on Medical and Biological Engineering 2017, Sarajevo, Bosnia and Herzegovina N2 - The gold standard for the analysis of human kinematics and kinetics is a camera-based motion capture system in combination with force measurement platforms. Alternatively, inertial measurement units can be utilized to obtain human kinematics, while ground reaction forces are computed from full body dynamics. This setup represents a system independent from the spatial confinement of a gait laboratory. The aim of this study is the comparison of the two methods by the investigation of lower limb kinematics and the resulting joint reaction forces within the ankle-, knee- and hip joints. For this purpose, human motion during gait was captured simultaneously by both measurement techniques. 13 trials from 8 different test subjects were evaluated in total. IMU data was processed with a quaternion based Kalman Filter. The data sets were implemented into a musculoskeletal simulation program in order to drive a virtual human body model. Each sensor was aligned to the gravitational and magnetic field vectors of the earth. The angles of flexions, extensions and rotations were analyzed to determine kinematic differences. Joint reaction forces defined kinetic dissimilarities. The overall kinematic differences of both models yielded root mean square errors of 7.62°, 6.02°, 4.95°, 2.79°, 2.38° and 3.56° for ankle flexion, subtalar eversion, knee flexion, hip external rotation, hip abduction and hip flexion, respectively. The proximo-distal differences in force peaks between the models yielded overall for the ankle, 57.33 %Bodyweight(BW) ± 46.86 %BW (16.66 %(Maximum peak to peak) ± 13.62 %) for the knee 37.09 %BW ± 29.33 %BW (17.65 % ± 15.44 %) and 32.03 %BW ± 24.33 %BW (15.6 % ± 12.54 %) for the hip. The overall outcome of this work investigated an approach independent of the common setup of the gait laboratory, thus enabling a cheaper and more flexible technology as an alternative. However, kinematic and thus kinetic differences remain rather large. Future work aims to improve the contact criterion for the calculation of the ground reaction forces and the implementation of a full-body calibration algorithm for the IMU system in order to counteract magnetic field disturbances. KW - Inertial Measurement Units KW - Multibody Simulation KW - Musculoskeletal Simulation KW - AnyBody KW - Motion Capture KW - Bewegungsapparat KW - Biomechanik KW - Motion Capturing KW - Mehrkörpersimulation KW - Ground Reaction Force Prediction KW - Gait KW - IMU KW - Joint Reaction Forces Y1 - 2017 U6 - https://doi.org/10.1007/978-981-10-4166-2_31 VL - Vol. 62 SP - 205 EP - 211 PB - Springer CY - Singapore ER - TY - GEN A1 - Adler, Ina A1 - Förstl, Nikolas A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Biomechanical exposition of the factors influencing the pelvic floor muscle activity T2 - ESB 2024, 29th Congress of the European Society of Biomechanics, 30 June-3 July 2024, Edinburgh, Scotland N2 - Introduction About 40 % of the women worldwide suffer from Pelvic Floor Dysfunctions [1]. In previous studies, musculoskeletal simulations helped to understand and facilitate the complex issues of musculoskeletal disorders in several different branches [2, 3]. A fundamental prerequisite for the generation of these models is to have a basic understanding of the stresses acting on the pelvic floor. The aim of this study is to investigate the biomechanical factors influencing the activity of the pelvic floor muscles by establishing a parameterised model. Methods To identify the factors that affect the pelvic floor muscles, the process is divided into several stages. The first step is to investigate the loads acting on the pelvic floor. For this, a simplified sagittal cross-sectional model of the upper body is analysed. The discretization of the abdominal cavity is presented with resulting force vectors representing the organs in the abdominal and pelvic region, the tensile force of the structures that fixate the organs as well as the intraabdominal pressure. A second step is the examination of the basic mechanics of the pelvic floor muscles. As the functional anatomy of these muscles demonstrate differences compared to other muscle groups [4], the understanding of how they differ is crucial for the construction of musculoskeletal models. After a static examination of loads on a simplified muscle model, an extended model including the physiological properties of a muscle must be involved in the considerations. Therefore, the influence of parameters such as the ideal muscle strength and fibre length, as well as elasticity or passive stiffness of the elements must be taken into account. The influencing factors of the variables can be analysed in a simplified pelvic floor muscle model by systematically changing the parameters. Results The process of analysing the factors influencing the activity of the pelvic floor muscles follows two main strategies. The review of the effects of the whole body identifies the forces acting on the pelvic floor muscles and effect their activity. With the examination of the basic mechanics of a simplified pelvic floor muscle model a better understanding is achieved of how the pelvic floor muscles absorb the loads acting in the body. Discussion This process results in the main influence factors on the activity of the pelvic floor. The consequent parameters form the basis for a biomechanically justified construction of musculoskeletal simulation models of the pelvic floor. Nevertheless, it must be considered, that these mechanical studies represent simplifications of the reality. References 1. Wang et al, Front Public Health, 10:975829, 2022. 2. Bulat et al., Curr Sports Med Rep, 18(6):210-216, 2019 3. Melzner et al., Eur J Obstet Gynecol Reprod Biol, 264:306-313, 2021 4. Ashton-Miller et al., Ann N Y Acad Sci, 1101:266-96, 2007 Y1 - 2024 ER - TY - VIDEO A1 - Auer, Simon A1 - Reinker, Lukas A1 - Süß, Franz A1 - Kubowitsch, Simone A1 - Krutsch, Werner A1 - Weber, Markus A1 - Renkawitz, Tobias A1 - Dendorfer, Sebastian T1 - Webcast: Effect of mental demand on leg loading in highly dynamic motion N2 - Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury. KW - Webcast KW - AnyBody KW - Stress KW - Football KW - Speedcourt Y1 - 2020 UR - https://www.youtube.com/watch?v=uSc_9XlnkaA ER - TY - JOUR A1 - Förstl, Nikolas A1 - Süß, Franz A1 - Englert, Carsten A1 - Dendorfer, Sebastian T1 - Design of a reverse shoulder implant to measure shoulder stiffness during implant component positioning JF - Medical Engineering & Physics N2 - To avoid dislocation of the shoulder joint after reverse total shoulder arthroplasty, it is important to achieve sufficient shoulder stability when placing the implant components during surgery. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this research was to develop a temporary reverse shoulder implant prototype that would allow intraoperative measurement of shoulder stiffness while varying the position of the implant components. Joint angle and torque measurement techniques were developed to determine shoulder stiffness. Hall sensors were used to measure the joint angles by converting the magnetic flux densities into angles. The accuracy of the joint angle measurements was tested using a test bench. Torques were determined by using thin-film pressure sensors. Various mechanical mechanisms for variable positioning of the implant components were integrated into the prototype. The results of the joint angle measurements showed measurement errors of less than 5° in a deflection range of ±15° adduction/abduction combined with ±45° flexion/extension. The proposed design provides a first approach for intra-operative assessment of shoulder stiffness. The findings can be used as a technological basis for further developments. Y1 - 2023 U6 - https://doi.org/10.1016/j.medengphy.2023.104059 N1 - Corresponding author: Sebstian Dendorfer VL - 121 PB - Elsevier ET - Journal Pre-proof ER - TY - JOUR A1 - Förstl, Nikolas A1 - Adler, Ina A1 - Süß, Franz A1 - Dendorfer, Sebastian T1 - Technologies for Evaluation of Pelvic Floor Functionality: A Systematic Review JF - Sensors N2 - Pelvic floor dysfunction is a common problem in women and has a negative impact on their quality of life. The aim of this review was to provide a general overview of the current state of technology used to assess pelvic floor functionality. It also provides literature research of the physiological and anatomical factors that correlate with pelvic floor health. This systematic review was conducted according to the PRISMA guidelines. The PubMed, ScienceDirect, Cochrane Library, and IEEE databases were searched for publications on sensor technology for the assessment of pelvic floor functionality. Anatomical and physiological parameters were identified through a manual search. In the systematic review, 114 publications were included. Twelve different sensor technologies were identified. Information on the obtained parameters, sensor position, test activities, and subject characteristics was prepared in tabular form from each publication. A total of 16 anatomical and physiological parameters influencing pelvic floor health were identified in 17 published studies and ranked for their statistical significance. Taken together, this review could serve as a basis for the development of novel sensors which could allow for quantifiable prevention and diagnosis, as well as particularized documentation of rehabilitation processes related to pelvic floor dysfunctions. Y1 - 2024 U6 - https://doi.org/10.3390/s24124001 N1 - Die Preprint-Version ist ebenfalls in diesem Repositorium verzeichnet unter: https://opus4.kobv.de/opus4-oth-regensburg/frontdoor/index/index/docId/7306 VL - 24 IS - 12 PB - MDPI ER - TY - GEN A1 - Förstl, Nikolas A1 - Süß, Franz A1 - Englert, Carsten A1 - Dendorfer, Sebastian T1 - Design of a reverse shoulder implant to measure shoulder stiffness during implant component positioning T2 - Book of abstracts / ESB 2023, 28th Congress of the European Society of Biomechanics, 9-12 July 2023, Maastricht, The Netherlands. N2 - Introduction Dislocation of the shoulder joint is one of the more common complications after reverse total shoulder arthroplasty [1], which is often associated with malposition of the prosthetic components [2]. Therefore, achieving sufficient shoulder stability should not be neglected when positioning the implant components. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this work is to develop a reverse shoulder implant prototype that allows intraoperative measurement of shoulder stiffness while varying the position of the implant components. The measured stiffness could provide a quantitative statement regarding the optimal positioning of the implant components, which can be adjusted accordingly in the final reverse shoulder prosthesis. Methods To measure the stiffness of the shoulder joint, it is necessary to record the joint angles and the torques generated during movement. The changes in the rotation angles were measured using 3D hall sensors and magnets. The magnets were placed under the humerosocket, and the hall sensors were integrated into the glenosphere. The strength of the magnetic field was used to determine the position of the humerosocket in relation to the glenosphere. The accuracies of the angle measurements were tested using a test bench. Three thin film pressure sensors were used to record forces at different points under the humerosocket. To obtain a force value from the sensor signal, the sensors were calibrated using a load cell. The variation of the implant components positions was integrated into the prototype implant through different constructive mechanisms to adjust the stiffness of the shoulder joint. Results In the range of ±45° flexion/extension combined with ±15° adduction/abduction, the joint position could be determined with sufficient accuracy (error e ≤ 5°). The areas near the combined maximum deflections of ±45° flexion/extension and ±45° adduction/abduction indicate the greatest deviation from the target angle. The force values of the thin film sensors enable the calculation of moments around two axes. As variable component position parameters, the tray offset, the neck-shaft angle and the humerus version were integrated into the implant prototype. Discussion Ideally, the accuracy of the angle measurements should only depend on the amount of deflection and not on the direction of deflection. The asymmetric behavior indicates a deviation from the correct positioning of the hall sensors. The application of a calibration matrix could compensate for the measurement errors and could demonstrate the potential of the new method for joint angle measurements. The accuracy of the torque measurements and the functionality of the mechanical arresting mechanisms must be investigated in further studies. Overall, the developed measurement method can help to avoid malpositioning of the implant components in reverse total shoulder arthroplasty. References 1. Clark et al, J Shoulder and elbow surgery, 21:36-41 2012. 2. Randelli et al, J Musculoskeletal surgery, 98:15-18, 2014. Y1 - 2023 UR - https://esbiomech.org/conference/archive/2023maastricht/332.pdf ER -