TY - JOUR A1 - Maier, Andreas A1 - Deserno, Thomas M. A1 - Handels, Heinz A1 - Maier-Hein, Klaus H. A1 - Palm, Christoph A1 - Tolxdorff, Thomas T1 - IJCARS: BVM 2021 special issue JF - International Journal of Computer Assisted Radiology and Surgery N2 - The German workshop on medical image computing (BVM) has been held in different locations in Germany for more than 20 years. In terms of content, BVM focused on the computer-aided analysis of medical image data with a wide range of applications, e.g. in the area of imaging, diagnostics, operation planning, computer-aided intervention and visualization. During this time, there have been remarkable methodological developments and upheavals, on which the BVM community has worked intensively. The area of machine learning should be emphasized, which has led to significant improvements, especially for tasks of classification and segmentation, but increasingly also in image formation and registration. As a result, work in connection with deep learning now dominates the BVM. These developments have also contributed to the establishment of medical image processing at the interface between computer science and medicine as one of the key technologies for the digitization of the health system. In addition to the presentation of current research results, a central aspect of the BVM is primarily the promotion of young scientists from the diverse BVM community, covering not only Germany but also Austria, Switzerland, The Netherland and other European neighbors. The conference serves primarily doctoral students and postdocs, but also students with excellent bachelor and master theses as a platform to present their work, to enter into professional discourse with the community, and to establish networks with specialist colleagues. Despite the many conferences and congresses that are also relevant for medical image processing, the BVM has therefore lost none of its importance and attractiveness and has retained its permanent place in the annual conference rhythm. Building on this foundation, there are some innovations and changes this year. The BVM 2021 was organized for the first time at the Ostbayerische Technische Hochschule Regensburg (OTH Regensburg, a technical university of applied sciences). After Aachen, Berlin, Erlangen, Freiburg, Hamburg, Heidelberg, Leipzig, Lübeck, and Munich, Regensburg is not just a new venue. OTH Regensburg is the first representative of the universities of applied sciences (HAW) to organize the conference, which differs to universities, university hospitals, or research centers like Fraunhofer or Helmholtz. This also considers the further development of the research landscape in Germany, where HAWs increasingly contribute to applied research in addition to their focus on teaching. This development is also reflected in the contributions submitted to the BVM in recent years. At BVM 2021, which was held in a virtual format for the first time due to the Corona pandemic, an attractive and high-quality program was offered. Fortunately, the number of submissions increased significantly. Out of 97 submissions, 26 presentations, 51 posters and 5 software demonstrations were accepted via an anonymized reviewing process with three reviews each. The three best works have been awarded BVM prizes, selected by a separate committee. Based on these high-quality submissions, we are able to present another special issue in the International Journal of Computer Assisted Radiology and Surgery (IJCARS). Out of the 97 submissions, the ones with the highest scores have been invited to submit an extended version of their paper to be presented in IJCARS. As a result, we are now able to present this special issue with seven excellent articles. Many submissions focus on machine learning in a medical context. KW - Medical Image Computing KW - Bildgebendes Verfahren KW - Medizin Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-21666 VL - 16 SP - 2067 EP - 2068 PB - Springer ER - TY - JOUR A1 - Schulze, Elke A1 - Palm, Christoph A1 - Kerschbaum, Maximilian A1 - Seidel, Roman A1 - Lehmann, Lars A1 - Koller, Michael A1 - Pfingsten, Andrea T1 - KI-gestützte Untersuchung in der nicht-operativen Versorgung symptomgebender Erkrankungen des Kniegelenks – ein multiprofessionelles Konzept (KINEESIO) JF - MSK – Muskuloskelettale Physiotherapie N2 - Beschwerdebilder am Kniegelenk aufgrund muskuloskelettaler degenerativer oder verletzungsbedingter Erkrankungen sind häufig, nehmen im Alter zu und sind mit der steigenden Inanspruchnahme ärztlicher und therapeutischer Behandlungsmaßnahmen verbunden. Einer erfolgreichen Therapie gehen oft notwendige zeit- und ressourcenaufwendige Untersuchungen zur Erkennung und Differenzierung der patient*innenspezifischen Problematik voraus. Im Zusammenhang mit der nicht-operativen Versorgung des Kniegelenks hat ein sektorübergreifendes multiprofessionelles Forschungsteam ein Konzept entwickelt, um künstliche neuronale Netze so zu trainieren, dass sie bei der ärztlichen und physiotherapeutischen Untersuchung unterstützend Einsatz finden können. Denn gerade in der Erfassung und Auswertung umfassender Datenmengen liegen große Potenziale in der Künstlichen Intelligenz (KI) im Gesundheitswesen. Das Projekt KINEESIO trainiert und testet KI-gestützte Screening- Tools zur Untersuchung von Patient*innen mit Kniegelenkerkrankungen. Diese unterstützen die Abläufe zwischen Leistungserbringern und Patient*innen, tragen zu einer verbesserten Differenzierung individueller Beschwerdebilder bei und dienen Entscheidungsprozessen für eine adäquate Versorgung. Dadurch sollen Ressourcen im Gesundheitswesen geschont und eine qualitativ hochwertige Therapie ausreichend ermöglicht werden. N2 - Complaints regarding knee joints resulting from musculoskeletal degenerative or injury-related conditions are common, increase with age, and are associated with rising demand for treatments by physicians and therapists. The success of a therapeutic intervention is frequently contingent upon necessary time- and resource-intensive examinations to identify and differentiate the patient’s specific issues. In connection with non-surgical knee joint treatment, a crosssectoral, multidisciplinary research team has developed a concept for training artificial neural networks to assist in medical and physiotherapeutic examinations. After all, there is great potential for artificial intelligence (AI) in healthcare, particularly in collecting and analyzing large amounts of data. The KINEESIO project is training and testing screening tools supported by artificial intelligence for the assessment of patients with knee joint disorders. These tools support the workflows between healthcare providers and patients, improve the differentiation of individual symptoms and serve the decisionmaking process towards appropriate care. This should conserve healthcare resources and enable sufficient high-quality treatment. KW - Physiotherapie KW - Diagnose KW - Kniegelenk KW - Künstliche Intelligenz Y1 - 2024 U6 - https://doi.org/10.1055/a-2402-9982 SN - 2701-6986 VL - 28 IS - 5 SP - 312 EP - 321 PB - Thieme ER - TY - JOUR A1 - Hartmann, Robin A1 - Weiherer, Maximilian A1 - Schiltz, Daniel A1 - Seitz, Stephan A1 - Lotter, Luisa A1 - Anker, Alexandra A1 - Palm, Christoph A1 - Prantl, Lukas A1 - Brébant, Vanessa T1 - A Novel Method of Outcome Assessment in Breast Reconstruction Surgery: Comparison of Autologous and Alloplastic Techniques Using Three-Dimensional Surface Imaging JF - Aesthetic Plastic Surgery N2 - Background Breast reconstruction is an important coping tool for patients undergoing a mastectomy. There are numerous surgical techniques in breast reconstruction surgery (BRS). Regardless of the technique used, creating a symmetric outcome is crucial for patients and plastic surgeons. Three-dimensional surface imaging enables surgeons and patients to assess the outcome’s symmetry in BRS. To discriminate between autologous and alloplastic techniques, we analyzed both techniques using objective optical computerized symmetry analysis. Software was developed that enables clinicians to assess optical breast symmetry using three-dimensional surface imaging. Methods Twenty-seven patients who had undergone autologous (n = 12) or alloplastic (n = 15) BRS received three-dimensional surface imaging. Anthropomorphic data were collected digitally using semiautomatic measurements and automatic measurements. Automatic measurements were taken using the newly developed software. To quantify symmetry, a Symmetry Index is proposed. Results Statistical analysis revealed that there is no dif- ference in the outcome symmetry between the two groups (t test for independent samples; p = 0.48, two-tailed). Conclusion This study’s findings provide a foundation for qualitative symmetry assessment in BRS using automatized digital anthropometry. In the present trial, no difference in the outcomes’ optical symmetry was detected between autologous and alloplastic approaches. KW - Breast reconstruction KW - Breast symmetry KW - Digital anthropometry KW - Mammoplastik KW - Dreidimensionale Bildverarbeitung KW - Autogene Transplantation KW - Alloplastik Y1 - 2020 U6 - https://doi.org/10.1007/s00266-020-01749-4 VL - 44 SP - 1980 EP - 1987 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Hartmann, Robin A1 - Weiherer, Maximilian A1 - Schiltz, Daniel A1 - Baringer, Magnus A1 - Noisser, Vivien A1 - Hösl, Vanessa A1 - Eigenberger, Andreas A1 - Seitz, Stefan A1 - Palm, Christoph A1 - Prantl, Lukas A1 - Brébant, Vanessa T1 - New aspects in digital breast assessment: further refinement of a method for automated digital anthropometry JF - Archives of Gynecology and Obstetrics N2 - Purpose: In this trial, we used a previously developed prototype software to assess aesthetic results after reconstructive surgery for congenital breast asymmetry using automated anthropometry. To prove the consensus between the manual and automatic digital measurements, we evaluated the software by comparing the manual and automatic measurements of 46 breasts. Methods: Twenty-three patients who underwent reconstructive surgery for congenital breast asymmetry at our institution were examined and underwent 3D surface imaging. Per patient, 14 manual and 14 computer-based anthropometric measurements were obtained according to a standardized protocol. Manual and automatic measurements, as well as the previously proposed Symmetry Index (SI), were compared. Results: The Wilcoxon signed-rank test revealed no significant differences in six of the seven measurements between the automatic and manual assessments. The SI showed robust agreement between the automatic and manual methods. Conclusion: The present trial validates our method for digital anthropometry. Despite the discrepancy in one measurement, all remaining measurements, including the SI, showed high agreement between the manual and automatic methods. The proposed data bring us one step closer to the long-term goal of establishing robust instruments to evaluate the results of breast surgery. KW - digital anthropometry KW - reconstructive surgery KW - 3D surface imaging Y1 - 2021 U6 - https://doi.org/10.1007/s00404-020-05862-2 SN - 1432-0711 VL - 303 SP - 721 EP - 728 PB - Springer Nature CY - Heidelberg ER - TY - CHAP A1 - Mendel, Robert A1 - Souza Jr., Luis Antonio de A1 - Rauber, David A1 - Papa, João Paulo A1 - Palm, Christoph T1 - Semi-supervised Segmentation Based on Error-Correcting Supervision T2 - Computer vision - ECCV 2020: 16th European conference, Glasgow, UK, August 23-28, 2020, Proceedings, Part XXIX N2 - Pixel-level classification is an essential part of computer vision. For learning from labeled data, many powerful deep learning models have been developed recently. In this work, we augment such supervised segmentation models by allowing them to learn from unlabeled data. Our semi-supervised approach, termed Error-Correcting Supervision, leverages a collaborative strategy. Apart from the supervised training on the labeled data, the segmentation network is judged by an additional network. The secondary correction network learns on the labeled data to optimally spot correct predictions, as well as to amend incorrect ones. As auxiliary regularization term, the corrector directly influences the supervised training of the segmentation network. On unlabeled data, the output of the correction network is essential to create a proxy for the unknown truth. The corrector’s output is combined with the segmentation network’s prediction to form the new target. We propose a loss function that incorporates both the pseudo-labels as well as the predictive certainty of the correction network. Our approach can easily be added to supervised segmentation models. We show consistent improvements over a supervised baseline on experiments on both the Pascal VOC 2012 and the Cityscapes datasets with varying amounts of labeled data. KW - Semi-Supervised Learning KW - Machine Learning Y1 - 2020 SN - 978-3-030-58525-9 U6 - https://doi.org/10.1007/978-3-030-58526-6_9 SP - 141 EP - 157 PB - Springer CY - Cham ER - TY - CHAP A1 - Palm, Christoph A1 - Scholl, Ingrid A1 - Lehmann, Thomas M. A1 - Spitzer, Klaus ED - Lehmann, Thomas M. ED - Scholl, Ingrid ED - Spitzer, Klaus T1 - Trennung von diffuser und spiegelnder Reflexion in Farbbildern des Larynx zur Untersuchung von Farb- und Formmerkmalen der Stimmlippen T2 - Bildverarbeitung für die Medizin. Algorithmen, Systeme, Anwendungen. Proceedings des Aachener Workshops am 8. und 9. November 1996 N2 - Zur diagnostischen Unterstützung bei der Befundung laryngealer Erkrankungen soll eine Farb- und Formanalyse der Stimmlippen durchgeführt werden. In diesem Beitrag wird ein Verfahren zur Trennung der spiegelnden und diffusen Reflexionsanteile in Farbbildern des Larynx vorgestellt. Die Farbe der diffusen Komponente entspricht dabei der beleuchtungsunabhängigen Objektfarbe, während deren Wichtungsfaktoren als Eingabe für Shape-from-Shading-Verfahren zur Oberflächenrekonstruktion dienen. KW - Laryngoskopie KW - Farbbild KW - Reflexion Y1 - 1996 UR - https://scholar.google.de/citations?user=nc0XkcMAAAAJ&hl=fa#d=gs_md_cita-d&u=%2Fcitations%3Fview_op%3Dview_citation%26hl%3Dfa%26user%3Dnc0XkcMAAAAJ%26citation_for_view%3Dnc0XkcMAAAAJ%3AqjMakFHDy7sC%26tzom%3D-120 SP - 229 EP - 234 PB - Verlag der Augustinus-Buchhandlung CY - Aachen ER - TY - CHAP A1 - Hassan, H. A1 - Ilgner, Justus F. R. A1 - Palm, Christoph A1 - Lehmann, Thomas M. A1 - Spitzer, Klaus A1 - Westhofen, Martin ED - Lehmann, Thomas M. ED - Spitzer, Klaus ED - Tolxdorff, Thomas T1 - Objective Judgement of Endoscopic Laryngeal Images T2 - Advances in Quantitative Laryngoscopy, Voice and Speech Research, Proceedings of the 3rd International Workshop, RWTH Aachen N2 - Video Documentation of endoscopic findings simplifies diagnostic counseling of the patient and aids pre-operative discussion among the medical team. Judgment of such images is still subjective and can not give a quantitative evaluation of the disease process regarding diagnosis or response to treatment. Modern treatment of early laryngeal cancer with laserablation requires intensive follow up and frequent direct laryngoscopy under general anesthesia with blind biopsies to detect any tumor residual or recurrence. Inflammatory conditions of the larynx are frequently confused with other causes of dysphonia. Mapping anddigital analysis of the documented image will suggest the tumor site and avoids undue blind biopsies under anesthesia. However, varying illumination results in different colors reflected from the same object. To achieve quantitative analysis, color constancy has to be assured. Inthis paper, the environment is presented which allow the objective judgment of larngoscopies. KW - Laryngoscopy KW - Diagnosis KW - Image processing KW - Quantitative Image analysis KW - Colorconstancy Y1 - 1998 UR - https://citeseerx.ist.psu.edu/doc_view/pid/caf5bedf5cf68ed3be68054b140a1241f4f278e2 SP - 135 EP - 142 ER - TY - CHAP A1 - Scholl, Ingrid A1 - Palm, Christoph A1 - Sovakar, Abhijit A1 - Lehmann, Thomas M. A1 - Spitzer, Klaus ED - Arnolds, B. ED - Mueller, H. ED - Saupe, D. ED - Tolxdorff, Thomas T1 - Quantitative Analyse der Stimmlippen T2 - 5. Workshop Digitale Bildverarbeitung in der Medizin, Universität Freiburg, 10.-11. März 1997 KW - Konturverfolgung KW - Snakes KW - Farbanalyse KW - Dichromatisches Reflexionsmodell KW - Farbkonstanz KW - Laryngoskopie Y1 - 1997 UR - https://pdfs.semanticscholar.org/9a0c/9e7dc883ccf6e8a8a686c28422238adb5f35.pdf SP - 81 EP - 86 ER - TY - GEN A1 - Krefting, Dagmar A1 - Zaunseder, Sebastian A1 - Säring, Dennis A1 - Wittenberg, Thomas A1 - Palm, Christoph A1 - Schiecke, Karin A1 - Krenkel, Lars A1 - Hennemuth, Anja A1 - Schnell, Susanne A1 - Spicher, Nicolai T1 - Blutdruck, Hämodynamik und Gefäßzustand: Innovative Erfassung und Bewertung – Schwerpunkt bildbasierte Verfahren T2 - 66. Jahrestagung der Deutschen Gesellschaft für Medizinische Informatik, Biometrie und Epidemiologie e. V. (GMDS), 12. Jahreskongress der Technologie- und Methodenplattform für die vernetzte medizinische Forschung e. V. (TMF), 26. - 30.09.2021, online N2 - Einleitung: Blutdruck gilt als sogenannter Vitalparameter als einer der grundlegenden Indikatoren für den Gesundheitszustand einer Person. Sowohl zu niedriger als auch zu hoher Blutdruck kann lebensbedrohend sein, letzerer ist darüber hinaus ein Risikofaktor insbesondere für Herz-Kreislauferkrankungen, die trotz wichtiger Fortschritte in der Behandlung immer noch die häufigste Todesursache in Deutschland darstellen. Die Hämodynamik, also die raumzeitliche Dynamik des Blutflusses, und der Gefäßzustand sind eng verbunden mit dem Blutdruck und ebenfalls von hoher klinischer Relevanz, u.a. zur Identifikation von Durchblutungsstörungen und ungünstigen Druckverteilungen der Gefäßwand. Innovationen in der Messtechnik als auch in der Datenanalyse bieten heute neue Möglichkeiten der Erfassung und Bewertung von Blutdruck, Hämodynamik und Gefäßzustand [1], [2], [3], [4]. Methodik: In einer gemeinsamen Workshopserie der AG Medizinische Bild- und Signalverarbeitung der GMDS und des Fachausschusses Biosignale der DGBMT werden wir neue Ansätze und Lösungen für Mess- und Analyseverfahren zu Blutdruck und -fluss sowie zum Gefäßzustand vorstellen und diskutieren. Dabei stehen im ersten Workshop auf der GMDS Jahrestagung Bildbasierte Verfahren im Zentrum, während der zweite Workshop auf der DGBMT Jahrestagung den Fokus auf Biosignalbasierten Verfahren legt. Es werden aktuelle Forschungsergebnisse vorgestellt und diskutiert. Es sind jeweils mehrere Vorträge geplant mit ausreichend Zeit zur Diskussion. Folgende Vorträge sind geplant (Arbeitstitel): Sebastian Zaunseder: Videobasierte Erfassung des Blutdrucks Anja Hennemuth: A Visualization Toolkit for the Analysis of Aortic Anatomy and Pressure Distribution Lars Krenkel: Numerische Analyse der Rupturwahrscheinlichkeit zerebraler Aneurysmata Susanne Schnell: Messung des Blutflusses und hämodynamischer Parameter mit 4D flow MRI: Möglichkeiten und Herausforderungen Ergebnisse: Ziel des Workshops ist die Identifikation von innovativen Ansätzen und neuen Methoden zur qualitativen und quantitativen Bestimmung von hämodynamischen Parametern sowie deren kritische Bewertung durch die Community für die Eignung in der klinischen Entscheidungsunterstützung. Diskussion: Der Workshop leistet inhaltlich einen Beitrag zu zentralen Aspekten für die Herz-Kreislauf-Medizin. Er bringt dabei Expertise aus verschiedenen Bereichen zusammen und schlägt die Brücke zwischen Kardiologie, Medizininformatik und Medizintechnik. Schlussfolgerung: Innovative Technologien aus Medizintechnik und Informatik ermöglichen zunehmend einfache und raumzeitlich aufgelöste Erfassung und Bewertung wichtiger Informationen zur Unterstützung von Diagnose und Therapieverfolgung. [1] Zaunseder S, Trumpp A, Wedekind D, Malberg H. Cardiovascular assessment by imaging photoplethysmography - a review. Biomed Tech (Berl). 2018 Oct 25;63(5):617–34. [2] Huellebrand M, Messroghli D, Tautz L, Kuehne T, Hennemuth A. An extensible software platform for interdisciplinary cardiovascular imaging research. Comput Methods Programs Biomed. 2020 Feb;184:105277. [3] Schmitter S, Adriany G, Waks M, Moeller S, Aristova M, Vali A, et al. Bilateral Multiband 4D Flow MRI of the Carotid Arteries at 7T. Magn Reson Med. 2020 Oct;84(4):1947–60. [4] Birkenmaier C, and Krenkel, L. Flow in Artificial Lungs. In: New Results in Numerical and Experimental Fluid Mechanics XIII. Contributions to the 22nd STAB/DGLR Symposium. Springer; 2021. KW - Bildbasierte Verfahren KW - Blutdruck KW - Hämodynamik KW - Blutgefäß KW - Bildgebendes Verfahren Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0183-21gmds0167 ER - TY - JOUR A1 - Graßmann, Felix A1 - Mengelkamp, Judith A1 - Brandl, Caroline A1 - Harsch, Sebastian A1 - Zimmermann, Martina E. A1 - Linkohr, Birgit A1 - Peters, Annette A1 - Heid, Iris M. A1 - Palm, Christoph A1 - Weber, Bernhard H. F. T1 - A Deep Learning Algorithm for Prediction of Age-Related Eye Disease Study Severity Scale for Age-Related Macular Degeneration from Color Fundus Photography JF - Ophtalmology N2 - Purpose Age-related macular degeneration (AMD) is a common threat to vision. While classification of disease stages is critical to understanding disease risk and progression, several systems based on color fundus photographs are known. Most of these require in-depth and time-consuming analysis of fundus images. Herein, we present an automated computer-based classification algorithm. Design Algorithm development for AMD classification based on a large collection of color fundus images. Validation is performed on a cross-sectional, population-based study. Participants. We included 120 656 manually graded color fundus images from 3654 Age-Related Eye Disease Study (AREDS) participants. AREDS participants were >55 years of age, and non-AMD sight-threatening diseases were excluded at recruitment. In addition, performance of our algorithm was evaluated in 5555 fundus images from the population-based Kooperative Gesundheitsforschung in der Region Augsburg (KORA; Cooperative Health Research in the Region of Augsburg) study. Methods. We defined 13 classes (9 AREDS steps, 3 late AMD stages, and 1 for ungradable images) and trained several convolution deep learning architectures. An ensemble of network architectures improved prediction accuracy. An independent dataset was used to evaluate the performance of our algorithm in a population-based study. Main Outcome Measures. κ Statistics and accuracy to evaluate the concordance between predicted and expert human grader classification. Results. A network ensemble of 6 different neural net architectures predicted the 13 classes in the AREDS test set with a quadratic weighted κ of 92% (95% confidence interval, 89%–92%) and an overall accuracy of 63.3%. In the independent KORA dataset, images wrongly classified as AMD were mainly the result of a macular reflex observed in young individuals. By restricting the KORA analysis to individuals >55 years of age and prior exclusion of other retinopathies, the weighted and unweighted κ increased to 50% and 63%, respectively. Importantly, the algorithm detected 84.2% of all fundus images with definite signs of early or late AMD. Overall, 94.3% of healthy fundus images were classified correctly. Conclusions Our deep learning algoritm revealed a weighted κ outperforming human graders in the AREDS study and is suitable to classify AMD fundus images in other datasets using individuals >55 years of age. KW - Senile Makuladegeneration KW - Krankheitsverlauf KW - Mustererkennung KW - Maschinelles Lernen Y1 - 2018 U6 - https://doi.org/10.1016/j.ophtha.2018.02.037 N1 - Corresponding authors: Bernhard H. F. Weber, University of Regensburg, and Christoph Palm VL - 125 IS - 9 SP - 1410 EP - 1420 PB - Elsevier ER - TY - JOUR A1 - Hartmann, Robin A1 - Weiherer, Maximilian A1 - Nieberle, Felix A1 - Palm, Christoph A1 - Brébant, Vanessa A1 - Prantl, Lukas A1 - Lamby, Philipp A1 - Reichert, Torsten E. A1 - Taxis, Jürgen A1 - Ettl, Tobias T1 - Evaluating smartphone-based 3D imaging techniques for clinical application in oral and maxillofacial surgery: A comparative study with the vectra M5 JF - Oral and Maxillofacial Surgery N2 - PURPOSE This study aimed to clarify the applicability of smartphone-based three-dimensional (3D) surface imaging for clinical use in oral and maxillofacial surgery, comparing two smartphone-based approaches to the gold standard. METHODS Facial surface models (SMs) were generated for 30 volunteers (15 men, 15 women) using the Vectra M5 (Canfield Scientific, USA), the TrueDepth camera of the iPhone 14 Pro (Apple Inc., USA), and the iPhone 14 Pro with photogrammetry. Smartphone-based SMs were superimposed onto Vectra-based SMs. Linear measurements and volumetric evaluations were performed to evaluate surface-to-surface deviation. To assess inter-observer reliability, all measurements were performed independently by a second observer. Statistical analyses included Bland-Altman analyses, the Wilcoxon signed-rank test for paired samples, and Intraclass correlation coefficients. RESULTS Photogrammetry-based SMs exhibited an overall landmark-to-landmark deviation of M = 0.8 mm (SD =  ± 0.58 mm, n = 450), while TrueDepth-based SMs displayed a deviation of M = 1.1 mm (SD =  ± 0.72 mm, n = 450). The mean volumetric difference for photogrammetry-based SMs was M = 1.8 cc (SD =  ± 2.12 cc, n = 90), and M = 3.1 cc (SD =  ± 2.64 cc, n = 90) for TrueDepth-based SMs. When comparing the two approaches, most landmark-to-landmark measurements demonstrated 95% Bland-Altman limits of agreement (LoA) of ≤ 2 mm. Volumetric measurements revealed LoA > 2 cc. Photogrammetry-based measurements demonstrated higher inter-observer reliability for overall landmark-to-landmark deviation. CONCLUSION Both approaches for smartphone-based 3D surface imaging exhibit potential in capturing the face. Photogrammetry-based SMs demonstrated superior alignment and volumetric accuracy with Vectra-based SMs than TrueDepth-based SMs. KW - Three-dimensional Surface Imaging KW - Smartphone-based Surface Imaging TrueDepth Stereophotogrammetry Oral and Maxillofacial Surgery KW - TrueDepth KW - Stereophotogrammetry KW - Oral and Maxillofacial Surgery Y1 - 2025 U6 - https://doi.org/10.1007/s10006-024-01322-2 VL - 29 PB - Springer Nature ER - TY - JOUR A1 - Maier, Johannes A1 - Perret, Jerome A1 - Simon, Martina A1 - Schmitt-Rüth, Stephanie A1 - Wittenberg, Thomas A1 - Palm, Christoph T1 - Force-feedback assisted and virtual fixtures based K-wire drilling simulation JF - Computers in Biology and Medicine N2 - One common method to fix fractures of the human hand after an accident is an osteosynthesis with Kirschner wires (K-wires) to stabilize the bone fragments. The insertion of K-wires is a delicate minimally invasive surgery, because surgeons operate almost without a sight. Since realistic training methods are time consuming, costly and insufficient, a virtual-reality (VR) based training system for the placement of K-wires was developed. As part of this, the current work deals with the real-time bone drilling simulation using a haptic force-feedback device. To simulate the drilling, we introduce a virtual fixture based force-feedback drilling approach. By decomposition of the drilling task into individual phases, each phase can be handled individually to perfectly control the drilling procedure. We report about the related finite state machine (FSM), describe the haptic feedback of each state and explain, how to avoid jerking of the haptic force-feedback during state transition. The usage of the virtual fixture approach results in a good haptic performance and a stable drilling behavior. This was confirmed by 26 expert surgeons, who evaluated the virtual drilling on the simulator and rated it as very realistic. To make the system even more convincing, we determined real drilling feed rates through experimental pig bone drilling and transferred them to our system. Due to a constant simulation thread we can guarantee a precise drilling motion. Virtual fixtures based force-feedback calculation is able to simulate force-feedback assisted bone drilling with high quality and, thus, will have a great potential in developing medical applications. KW - Handchirurgie KW - Osteosynthese KW - Operationstechnik KW - Lernprogramm KW - Virtuelle Realität KW - Medical training system KW - Virtual fixtures KW - Virtual reality KW - Force-feedback haptic KW - Minimally invasive hand surgery KW - K-wire drilling Y1 - 2019 U6 - https://doi.org/10.1016/j.compbiomed.2019.103473 N1 - Corresponding author: Christoph Palm VL - 114 SP - 1 EP - 10 PB - Elsevier ER - TY - CHAP A1 - Souza, Luis A. A1 - Pacheco, André G.C. A1 - de Angelo, Gabriel G. A1 - Oliveira-Santos, Thiago A1 - Palm, Christoph A1 - Papa, João Paulo T1 - LiwTERM: A Lightweight Transformer-Based Model for Dermatological Multimodal Lesion Detection T2 - 2024 37th SIBGRAPI Conference on Graphics, Patterns and Images (SIBGRAPI), Manaus, Brazil, 9/30/2024 - 10/3/2024 N2 - Skin cancer is the most common type of cancer in the world, accounting for approximately 30% of all diagnosed tumors. Early diagnosis reduces mortality rates and prevents disfiguring effects in different body regions. In recent years, machine learning techniques, particularly deep learning, have shown promising results in this task, presenting studies that have demonstrated that combining a patient’s clinical information with images of the lesion is crucial for improving the classification of skin lesions. Despite that, meaningful use of clinical information with multiple images is mandatory, requiring further investigation. Thus, this project aims to contribute to developing multimodal machine learning-based models to cope with the skin lesion classification task employing a lightweight transformer model. As a main hypothesis, models can take multiple images from different sources as input, along with clinical information from the patient’s history, leading to a more reliable diagnosis. Our model deals with the not-trivial task of combining images and clinical information (from anamneses) concerning the skin lesions in a lightweight transformer architecture that does not demand high computation resources but still presents competitive classification results. KW - Lightweight Architectures KW - Trans- formers KW - Skin Lesion Detection KW - Deep learning Y1 - 2024 SN - 979-8-3503-7603-6 U6 - https://doi.org/10.1109/SIBGRAPI62404.2024.10716324 SP - 1 EP - 6 PB - IEEE ER - TY - CHAP A1 - Souza Jr., Luis Antonio de A1 - Passos, Leandro A. A1 - Mendel, Robert A1 - Ebigbo, Alanna A1 - Probst, Andreas A1 - Messmann, Helmut A1 - Palm, Christoph A1 - Papa, João Paulo T1 - Fine-tuning Generative Adversarial Networks using Metaheuristics BT - A Case Study on Barrett's Esophagus Identification T2 - Bildverarbeitung für die Medizin 2021. Proceedings, German Workshop on Medical Image Computing, Regensburg, March 7-9, 2021 N2 - Barrett's esophagus denotes a disorder in the digestive system that affects the esophagus' mucosal cells, causing reflux, and showing potential convergence to esophageal adenocarcinoma if not treated in initial stages. Thus, fast and reliable computer-aided diagnosis becomes considerably welcome. Nevertheless, such approaches usually suffer from imbalanced datasets, which can be addressed through Generative Adversarial Networks (GANs). Such techniques generate realistic images based on observed samples, even though at the cost of a proper selection of its hyperparameters. Many works employed a class of nature-inspired algorithms called metaheuristics to tackle the problem considering distinct deep learning approaches. Therefore, this paper's main contribution is to introduce metaheuristic techniques to fine-tune GANs in the context of Barrett's esophagus identification, as well as to investigate the feasibility of generating high-quality synthetic images for early-cancer assisted identification. KW - Endoskopie KW - Computerunterstützte Medizin KW - Deep Learning Y1 - 2021 SN - 978-3-658-33197-9 U6 - https://doi.org/10.1007/978-3-658-33198-6_50 SP - 205 EP - 210 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Szalo, Alexander Eduard A1 - Zehner, Alexander A1 - Palm, Christoph T1 - GraphMIC: Medizinische Bildverarbeitung in der Lehre T2 - Bildverarbeitung für die Medizin 2015; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 15. bis 17. März 2015 in Lübeck N2 - Die Lehre der medizinischen Bildverarbeitung vermittelt Kenntnisse mit einem breiten Methodenspektrum. Neben den Grundlagen der Verfahren soll ein Gefühl für eine geeignete Ausführungsreihenfolge und ihrer Wirkung auf medizinische Bilddaten entwickelt werden. Die Komplexität der Methoden erfordert vertiefte Programmierkenntnisse, sodass bereits einfache Operationen mit großem Programmieraufwand verbunden sind. Die Software GraphMIC stellt Bildverarbeitungsoperationen in Form interaktiver Knoten zur Verfügung und erlaubt das Arrangieren, Parametrisieren und Ausführen komplexer Verarbeitungssequenzen in einem Graphen. Durch den Fokus auf das Design einer Pipeline, weg von sprach- und frameworkspezifischen Implementierungsdetails, lassen sich grundlegende Prinzipien der Bildverarbeitung anschaulich erlernen. In diesem Beitrag stellen wir die visuelle Programmierung mit GraphMIC der nativen Implementierung äquivalenter Funktionen gegenüber. Die in C++ entwickelte Applikation basiert auf Qt, ITK, OpenCV, VTK und MITK. KW - Bildverarbeitung KW - Medizin KW - Hochschuldidaktik Y1 - 2015 U6 - https://doi.org/10.1007/978-3-662-46224-9_68 SP - 395 EP - 400 PB - Springer CY - Berlin ER - TY - CHAP A1 - Palm, Christoph ED - Byrne, Michael F. ED - Parsa, Nasim ED - Greenhill, Alexandra T. ED - Chahal, Daljeet ED - Ahmad, Omer ED - Bargci, Ulas T1 - History, Core Concepts, and Role of AI in Clinical Medicine T2 - AI in Clinical Medicine: A Practical Guide for Healthcare Professionals N2 - The field of AI is characterized by robust promises, astonishing successes, and remarkable breakthroughs. AI will play a major role in all domains of clinical medicine, but the role of AI in relation to the physician is not yet completely determined. The term artificial intelligence or AI is broad, and several different terms are used in this context that must be organized and demystified. This chapter will review the key concepts and methods of AI, and will introduce some of the different roles for AI in relation to the physician. KW - artificial intelligence KW - healthcare Y1 - 2023 SN - 978-1-119-79064-8 U6 - https://doi.org/10.1002/9781119790686.ch5 SP - 49 EP - 55 PB - Wiley ET - 1. Aufl. ER - TY - JOUR A1 - Römmele, Christoph A1 - Mendel, Robert A1 - Barrett, Caroline A1 - Kiesl, Hans A1 - Rauber, David A1 - Rückert, Tobias A1 - Kraus, Lisa A1 - Heinkele, Jakob A1 - Dhillon, Christine A1 - Grosser, Bianca A1 - Prinz, Friederike A1 - Wanzl, Julia A1 - Fleischmann, Carola A1 - Nagl, Sandra A1 - Schnoy, Elisabeth A1 - Schlottmann, Jakob A1 - Dellon, Evan S. A1 - Messmann, Helmut A1 - Palm, Christoph A1 - Ebigbo, Alanna T1 - An artificial intelligence algorithm is highly accurate for detecting endoscopic features of eosinophilic esophagitis JF - Scientific Reports N2 - The endoscopic features associated with eosinophilic esophagitis (EoE) may be missed during routine endoscopy. We aimed to develop and evaluate an Artificial Intelligence (AI) algorithm for detecting and quantifying the endoscopic features of EoE in white light images, supplemented by the EoE Endoscopic Reference Score (EREFS). An AI algorithm (AI-EoE) was constructed and trained to differentiate between EoE and normal esophagus using endoscopic white light images extracted from the database of the University Hospital Augsburg. In addition to binary classification, a second algorithm was trained with specific auxiliary branches for each EREFS feature (AI-EoE-EREFS). The AI algorithms were evaluated on an external data set from the University of North Carolina, Chapel Hill (UNC), and compared with the performance of human endoscopists with varying levels of experience. The overall sensitivity, specificity, and accuracy of AI-EoE were 0.93 for all measures, while the AUC was 0.986. With additional auxiliary branches for the EREFS categories, the AI algorithm (AI-EoEEREFS) performance improved to 0.96, 0.94, 0.95, and 0.992 for sensitivity, specificity, accuracy, and AUC, respectively. AI-EoE and AI-EoE-EREFS performed significantly better than endoscopy beginners and senior fellows on the same set of images. An AI algorithm can be trained to detect and quantify endoscopic features of EoE with excellent performance scores. The addition of the EREFS criteria improved the performance of the AI algorithm, which performed significantly better than endoscopists with a lower or medium experience level. KW - Artificial Intelligence KW - Smart Endoscopy KW - eosinophilic esophagitis Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-46928 VL - 12 PB - Nature Portfolio CY - London ER - TY - JOUR A1 - Roser, David A1 - Meinikheim, Michael A1 - Muzalyova, Anna A1 - Mendel, Robert A1 - Palm, Christoph A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Scheppach, Markus W. A1 - Römmele, Christoph A1 - Schnoy, Elisabeth A1 - Parsa, Nasim A1 - Byrne, Michael F. A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Artificial intelligence-assisted endoscopy and examiner confidence : a study on human–artificial intelligence interaction in Barrett's Esophagus (With Video) JF - DEN Open N2 - Objective Despite high stand-alone performance, studies demonstrate that artificial intelligence (AI)-supported endoscopic diagnostics often fall short in clinical applications due to human-AI interaction factors. This video-based trial on Barrett's esophagus aimed to investigate how examiner behavior, their levels of confidence, and system usability influence the diagnostic outcomes of AI-assisted endoscopy. Methods The present analysis employed data from a multicenter randomized controlled tandem video trial involving 22 endoscopists with varying degrees of expertise. Participants were tasked with evaluating a set of 96 endoscopic videos of Barrett's esophagus in two distinct rounds, with and without AI assistance. Diagnostic confidence levels were recorded, and decision changes were categorized according to the AI prediction. Additional surveys assessed user experience and system usability ratings. Results AI assistance significantly increased examiner confidence levels (p < 0.001) and accuracy. Withdrawing AI assistance decreased confidence (p < 0.001), but not accuracy. Experts consistently reported higher confidence than non-experts (p < 0.001), regardless of performance. Despite improved confidence, correct AI guidance was disregarded in 16% of all cases, and 9% of initially correct diagnoses were changed to incorrect ones. Overreliance on AI, algorithm aversion, and uncertainty in AI predictions were identified as key factors influencing outcomes. The System Usability Scale questionnaire scores indicated good to excellent usability, with non-experts scoring 73.5 and experts 85.6. Conclusions Our findings highlight the pivotal function of examiner behavior in AI-assisted endoscopy. To fully realize the benefits of AI, implementing explainable AI, improving user interfaces, and providing targeted training are essential. Addressing these factors could enhance diagnostic accuracy and confidence in clinical practice. Y1 - 2025 U6 - https://doi.org/10.1002/deo2.70150 VL - 6 IS - 1 PB - Wiley ER - TY - GEN A1 - Römmele, Christoph A1 - Mendel, Robert A1 - Rauber, David A1 - Rückert, Tobias A1 - Byrne, Michael F. A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Endoscopic Diagnosis of Eosinophilic Esophagitis Using a deep Learning Algorithm T2 - Endoscopy N2 - Aims Eosinophilic esophagitis (EoE) is easily missed during endoscopy, either because physicians are not familiar with its endoscopic features or the morphologic changes are too subtle. In this preliminary paper, we present the first attempt to detect EoE in endoscopic white light (WL) images using a deep learning network (EoE-AI). Methods 401 WL images of eosinophilic esophagitis and 871 WL images of normal esophageal mucosa were evaluated. All images were assessed for the Endoscopic Reference score (EREFS) (edema, rings, exudates, furrows, strictures). Images with strictures were excluded. EoE was defined as the presence of at least 15 eosinophils per high power field on biopsy. A convolutional neural network based on the ResNet architecture with several five-fold cross-validation runs was used. Adding auxiliary EREFS-classification branches to the neural network allowed the inclusion of the scores as optimization criteria during training. EoE-AI was evaluated for sensitivity, specificity, and F1-score. In addition, two human endoscopists evaluated the images. Results EoE-AI showed a mean sensitivity, specificity, and F1 of 0.759, 0.976, and 0.834 respectively, averaged over the five distinct cross-validation runs. With the EREFS-augmented architecture, a mean sensitivity, specificity, and F1-score of 0.848, 0.945, and 0.861 could be demonstrated respectively. In comparison, the two human endoscopists had an average sensitivity, specificity, and F1-score of 0.718, 0.958, and 0.793. Conclusions To the best of our knowledge, this is the first application of deep learning to endoscopic images of EoE which were also assessed after augmentation with the EREFS-score. The next step is the evaluation of EoE-AI using an external dataset. We then plan to assess the EoE-AI tool on endoscopic videos, and also in real-time. This preliminary work is encouraging regarding the ability for AI to enhance physician detection of EoE, and potentially to do a true “optical biopsy” but more work is needed. KW - Eosinophilic Esophagitis KW - Endoscopy KW - Deep Learning Y1 - 2021 U6 - https://doi.org/10.1055/s-0041-1724274 VL - 53 IS - S 01 PB - Georg Thieme Verlag CY - Stuttgart ER - TY - JOUR A1 - Scheppach, Markus W. A1 - Rauber, David A1 - Stallhofer, Johannes A1 - Muzalyova, Anna A1 - Otten, Vera A1 - Manzeneder, Carolin A1 - Schwamberger, Tanja A1 - Wanzl, Julia A1 - Schlottmann, Jakob A1 - Tadic, Vidan A1 - Probst, Andreas A1 - Schnoy, Elisabeth A1 - Römmele, Christoph A1 - Fleischmann, Carola A1 - Meinikheim, Michael A1 - Miller, Silvia A1 - Märkl, Bruno A1 - Stallmach, Andreas A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Detection of duodenal villous atrophy on endoscopic images using a deep learning algorithm JF - Gastrointestinal Endoscopy N2 - Background and aims Celiac disease with its endoscopic manifestation of villous atrophy is underdiagnosed worldwide. The application of artificial intelligence (AI) for the macroscopic detection of villous atrophy at routine esophagogastroduodenoscopy may improve diagnostic performance. Methods A dataset of 858 endoscopic images of 182 patients with villous atrophy and 846 images from 323 patients with normal duodenal mucosa was collected and used to train a ResNet 18 deep learning model to detect villous atrophy. An external data set was used to test the algorithm, in addition to six fellows and four board certified gastroenterologists. Fellows could consult the AI algorithm’s result during the test. From their consultation distribution, a stratification of test images into “easy” and “difficult” was performed and used for classified performance measurement. Results External validation of the AI algorithm yielded values of 90 %, 76 %, and 84 % for sensitivity, specificity, and accuracy, respectively. Fellows scored values of 63 %, 72 % and 67 %, while the corresponding values in experts were 72 %, 69 % and 71 %, respectively. AI consultation significantly improved all trainee performance statistics. While fellows and experts showed significantly lower performance for “difficult” images, the performance of the AI algorithm was stable. Conclusion In this study, an AI algorithm outperformed endoscopy fellows and experts in the detection of villous atrophy on endoscopic still images. AI decision support significantly improved the performance of non-expert endoscopists. The stable performance on “difficult” images suggests a further positive add-on effect in challenging cases. KW - celiac disease KW - villous atrophy KW - endoscopy detection KW - artificial intelligence Y1 - 2023 U6 - https://doi.org/10.1016/j.gie.2023.01.006 PB - Elsevier ER - TY - GEN A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Probst, Andreas A1 - Scheppach, Markus W. A1 - Schnoy, Elisabeth A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Prinz, Friederike A1 - Schlottmann, Jakob A1 - Golger, Daniela A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - AI-assisted detection and characterization of early Barrett's neoplasia: Results of an Interim analysis T2 - Endoscopy N2 - Aims  Evaluation of the add-on effect an artificial intelligence (AI) based clinical decision support system has on the performance of endoscopists with different degrees of expertise in the field of Barrett's esophagus (BE) and Barrett's esophagus-related neoplasia (BERN). Methods  The support system is based on a multi-task deep learning model trained to solve a segmentation and several classification tasks. The training approach represents an extension of the ECMT semi-supervised learning algorithm. The complete system evaluates a decision tree between estimated motion, classification, segmentation, and temporal constraints, to decide when and how the prediction is highlighted to the observer. In our current study, ninety-six video cases of patients with BE and BERN were prospectively collected and assessed by Barrett's specialists and non-specialists. All video cases were evaluated twice – with and without AI assistance. The order of appearance, either with or without AI support, was assigned randomly. Participants were asked to detect and characterize regions of dysplasia or early neoplasia within the video sequences. Results  Standalone sensitivity, specificity, and accuracy of the AI system were 92.16%, 68.89%, and 81.25%, respectively. Mean sensitivity, specificity, and accuracy of expert endoscopists without AI support were 83,33%, 58,20%, and 71,48 %, respectively. Gastroenterologists without Barrett's expertise but with AI support had a comparable performance with a mean sensitivity, specificity, and accuracy of 76,63%, 65,35%, and 71,36%, respectively. Conclusions  Non-Barrett's experts with AI support had a similar performance as experts in a video-based study. Y1 - 2023 U6 - https://doi.org/10.1055/s-0043-1765437 VL - 55 IS - S02 PB - Thieme ER - TY - JOUR A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Muzalyova, Anna A1 - Rauber, David A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Yip, Hon Chi A1 - Lau, Louis Ho Shing A1 - Gölder, Stefan Karl A1 - Schmidt, Arthur A1 - Kouladouros, Konstantinos A1 - Abdelhafez, Mohamed A1 - Walter, Benjamin M. A1 - Meinikheim, Michael A1 - Chiu, Philip Wai Yan A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Artificial intelligence improves submucosal vessel detection during third space endoscopy JF - Endoscopy N2 - Background and study aims: While artificial intelligence (AI) shows high potential in decision support for diagnostic gastrointestinal endoscopy, its role in therapeutic endoscopy remains unclear. Third space endoscopic procedures pose the risk of intraprocedural bleeding. Therefore, we aimed to develop an AI algorithm for intraprocedural blood vessel detection. Patients and Methods: Using a test dataset with 101 standardized video clips containing 200 predefined submucosal blood vessels, 19 endoscopists were evaluated for the vessel detection rate (VDR) and time (VDT) with and without support of an AI algorithm. Test subjects were grouped according to experience in ESD. Results: With AI support, endoscopists VDR increased from 56.4% [CI 54.1–58.6] to 72.4% [CI 70.3–74.4]. Endoscopists‘ VDT dropped from 6.7sec [CI 6.2-7.1] to 5.2sec [CI 4.8-5.7]. False positive (FP) readings appeared in 4.5% of frames and were marked significantly shorter than true positives (6.0sec [CI 5.28-6.70] vs. 0.7sec [CI 0.55-0.87]). Conclusions: AI improved the vessel detection rate and time of endoscopists during third space endoscopy. While these data need to be corroborated by clinical trials, AI may prove to be an invaluable tool for the improvement of endoscopic interventions. KW - Artificial Intelligence KW - Third Space Endoscopy Y1 - 2025 U6 - https://doi.org/10.1055/a-2534-1164 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Rückert, Tobias A1 - Rückert, Daniel A1 - Palm, Christoph T1 - Methods and datasets for segmentation of minimally invasive surgical instruments in endoscopic images and videos: A review of the state of the art JF - Computers in Biology and Medicine N2 - In the field of computer- and robot-assisted minimally invasive surgery, enormous progress has been made in recent years based on the recognition of surgical instruments in endoscopic images and videos. In particular, the determination of the position and type of instruments is of great interest. Current work involves both spatial and temporal information, with the idea that predicting the movement of surgical tools over time may improve the quality of the final segmentations. The provision of publicly available datasets has recently encouraged the development of new methods, mainly based on deep learning. In this review, we identify and characterize datasets used for method development and evaluation and quantify their frequency of use in the literature. We further present an overview of the current state of research regarding the segmentation and tracking of minimally invasive surgical instruments in endoscopic images and videos. The paper focuses on methods that work purely visually, without markers of any kind attached to the instruments, considering both single-frame semantic and instance segmentation approaches, as well as those that incorporate temporal information. The publications analyzed were identified through the platforms Google Scholar, Web of Science, and PubMed. The search terms used were “instrument segmentation”, “instrument tracking”, “surgical tool segmentation”, and “surgical tool tracking”, resulting in a total of 741 articles published between 01/2015 and 07/2023, of which 123 were included using systematic selection criteria. A discussion of the reviewed literature is provided, highlighting existing shortcomings and emphasizing the available potential for future developments. KW - Deep Learning KW - Minimal-invasive Chirurgie KW - Bildsegmentierung KW - Surgical instrument segmentation KW - Surgical instrument tracking KW - Spatio-temporal information KW - Endoscopic surgery KW - Robot-assisted surgery Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-69830 N1 - Corresponding author: Tobias Rückert N1 - Corrigendum unter: https://opus4.kobv.de/opus4-oth-regensburg/frontdoor/index/index/docId/7033 VL - 169 PB - Elsevier CY - Amsterdam ER - TY - INPR A1 - Allan, Max A1 - Kondo, Satoshi A1 - Bodenstedt, Sebastian A1 - Leger, Stefan A1 - Kadkhodamohammadi, Rahim A1 - Luengo, Imanol A1 - Fuentes, Felix A1 - Flouty, Evangello A1 - Mohammed, Ahmed A1 - Pedersen, Marius A1 - Kori, Avinash A1 - Alex, Varghese A1 - Krishnamurthi, Ganapathy A1 - Rauber, David A1 - Mendel, Robert A1 - Palm, Christoph A1 - Bano, Sophia A1 - Saibro, Guinther A1 - Shih, Chi-Sheng A1 - Chiang, Hsun-An A1 - Zhuang, Juntang A1 - Yang, Junlin A1 - Iglovikov, Vladimir A1 - Dobrenkii, Anton A1 - Reddiboina, Madhu A1 - Reddy, Anubhav A1 - Liu, Xingtong A1 - Gao, Cong A1 - Unberath, Mathias A1 - Kim, Myeonghyeon A1 - Kim, Chanho A1 - Kim, Chaewon A1 - Kim, Hyejin A1 - Lee, Gyeongmin A1 - Ullah, Ihsan A1 - Luna, Miguel A1 - Park, Sang Hyun A1 - Azizian, Mahdi A1 - Stoyanov, Danail A1 - Maier-Hein, Lena A1 - Speidel, Stefanie T1 - 2018 Robotic Scene Segmentation Challenge N2 - In 2015 we began a sub-challenge at the EndoVis workshop at MICCAI in Munich using endoscope images of exvivo tissue with automatically generated annotations from robot forward kinematics and instrument CAD models. However, the limited background variation and simple motion rendered the dataset uninformative in learning about which techniques would be suitable for segmentation in real surgery. In 2017, at the same workshop in Quebec we introduced the robotic instrument segmentation dataset with 10 teams participating in the challenge to perform binary, articulating parts and type segmentation of da Vinci instruments. This challenge included realistic instrument motion and more complex porcine tissue as background and was widely addressed with modfications on U-Nets and other popular CNN architectures [1]. In 2018 we added to the complexity by introducing a set of anatomical objects and medical devices to the segmented classes. To avoid over-complicating the challenge, we continued with porcine data which is dramatically simpler than human tissue due to the lack of fatty tissue occluding many organs. KW - Minimally invasive surgery KW - Robotic KW - Minimal-invasive Chirurgie KW - Robotik Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-50049 UR - https://arxiv.org/abs/2001.11190 ER - TY - GEN A1 - Scheppach, Markus W. A1 - Rauber, David A1 - Mendel, Robert A1 - Palm, Christoph A1 - Byrne, Michael F. A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Detection Of Celiac Disease Using A Deep Learning Algorithm T2 - Endoscopy N2 - Aims Celiac disease (CD) is a complex condition caused by an autoimmune reaction to ingested gluten. Due to its polymorphic manifestation and subtle endoscopic presentation, the diagnosis is difficult and thus the disorder is underreported. We aimed to use deep learning to identify celiac disease on endoscopic images of the small bowel. Methods Patients with small intestinal histology compatible with CD (MARSH classification I-III) were extracted retrospectively from the database of Augsburg University hospital. They were compared to patients with no clinical signs of CD and histologically normal small intestinal mucosa. In a first step MARSH III and normal small intestinal mucosa were differentiated with the help of a deep learning algorithm. For this, the endoscopic white light images were divided into five equal-sized subsets. We avoided splitting the images of one patient into several subsets. A ResNet-50 model was trained with the images from four subsets and then validated with the remaining subset. This process was repeated for each subset, such that each subset was validated once. Sensitivity, specificity, and harmonic mean (F1) of the algorithm were determined. Results The algorithm showed values of 0.83, 0.88, and 0.84 for sensitivity, specificity, and F1, respectively. Further data showing a comparison between the detection rate of the AI model and that of experienced endoscopists will be available at the time of the upcoming conference. Conclusions We present the first clinical report on the use of a deep learning algorithm for the detection of celiac disease using endoscopic images. Further evaluation on an external data set, as well as in the detection of CD in real-time, will follow. However, this work at least suggests that AI can assist endoscopists in the endoscopic diagnosis of CD, and ultimately may be able to do a true optical biopsy in live-time. KW - Celiac Disease KW - Deep Learning Y1 - 2021 U6 - https://doi.org/10.1055/s-0041-1724970 N1 - Digital poster exhibition VL - 53 IS - S 01 PB - Georg Thieme Verlag CY - Stuttgart ER - TY - JOUR A1 - Ruewe, Marc A1 - Eigenberger, Andreas A1 - Klein, Silvan A1 - von Riedheim, Antonia A1 - Gugg, Christine A1 - Prantl, Lukas A1 - Palm, Christoph A1 - Weiherer, Maximilian A1 - Zeman, Florian A1 - Anker, Alexandra T1 - Precise Monitoring of Returning Sensation in Digital Nerve Lesions by 3-D Imaging: A Proof-of-Concept Study JF - Plastic and Reconstructive Surgery N2 - Digital nerve lesions result in a loss of tactile sensation reflected by an anesthetic area (AA) at the radial or ulnar aspect of the respective digit. Yet, available tools to monitor the recovery of tactile sense have been criticized for their lack of validity. However, the precise quantification of AA dynamics by three-dimensional (3-D) imaging could serve as an accurate surrogate to monitor recovery following digital nerve repair. For validation, AAs were marked on digits of healthy volunteers to simulate the AA of an impaired cutaneous innervation. Three dimensional models were composed from raw images that had been acquired with a 3-D camera (Vectra H2) to precisely quantify relative AA for each digit (3-D models, n= 80). Operator properties varied regarding individual experience in 3-D imaging and image processing. Additionally, the concept was applied in a clinical case study. Images taken by experienced photographers were rated better quality (p< 0.001) and needed less processing time (p= 0.020). Quantification of the relative AA was neither altered significantly by experience levels of the photographer (p= 0.425) nor the image assembler (p= 0.749). The proposed concept allows precise and reliable surface quantification of digits and can be performed consistently without relevant distortion by lack of examiner experience. Routine 3-D imaging of the AA has the great potential to provide visual evidence of various returning states of sensation and to convert sensory nerve recovery into a metric variable with high responsiveness to temporal progress. KW - 3D imaging Y1 - 2023 U6 - https://doi.org/10.1097/PRS.0000000000010456 SN - 1529-4242 VL - 152 IS - 4 SP - 670e EP - 674e PB - Lippincott Williams & Wilkins CY - Philadelphia, Pa. ER - TY - INPR A1 - Weiherer, Maximilian A1 - von Riedheim, Antonia A1 - Brébant, Vanessa A1 - Egger, Bernhard A1 - Palm, Christoph T1 - iRBSM: A Deep Implicit 3D Breast Shape Model N2 - We present the first deep implicit 3D shape model of the female breast, building upon and improving the recently proposed Regensburg Breast Shape Model (RBSM). Compared to its PCA-based predecessor, our model employs implicit neural representations; hence, it can be trained on raw 3D breast scans and eliminates the need for computationally demanding non-rigid registration -- a task that is particularly difficult for feature-less breast shapes. The resulting model, dubbed iRBSM, captures detailed surface geometry including fine structures such as nipples and belly buttons, is highly expressive, and outperforms the RBSM on different surface reconstruction tasks. Finally, leveraging the iRBSM, we present a prototype application to 3D reconstruct breast shapes from just a single image. Model and code publicly available at this https URL. KW - Shape Model KW - Female Breast KW - Regensburg Breast Shape Model Y1 - 2024 U6 - https://doi.org/10.48550/arXiv.2412.13244 ER - TY - GEN A1 - Ebigbo, Alanna A1 - Mendel, Robert A1 - Tziatzios, Georgios A1 - Probst, Andreas A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Real-Time Diagnosis of an Early Barrett's Carcinoma using Artificial Intelligence (AI) - Video Case Demonstration T2 - Endoscopy N2 - Introduction We present a clinical case showing the real-time detection, characterization and delineation of an early Barrett’s cancer using AI. Patients and methods A 70-year old patient with a long-segment Barrett’s esophagus (C5M7) was assessed with an AI algorithm. Results The AI system detected a 10 mm focal lesion and AI characterization predicted cancer with a probability of >90%. After ESD resection, histopathology showed mucosal adenocarcinoma (T1a (m), R0) confirming AI diagnosis. Conclusion We demonstrate the real-time AI detection, characterization and delineation of a small and early mucosal Barrett’s cancer. KW - Artificial Intelligence KW - Barrett's Carcinoma KW - Speiseröhrenkrebs KW - Künstliche Intelligenz KW - Diagnose Y1 - 2020 U6 - https://doi.org/10.1055/s-0040-1704075 VL - 52 IS - S 01 PB - Thieme ER - TY - CHAP A1 - Nunes, Danilo Weber A1 - Hammer, Michael A1 - Hammer, Simone A1 - Uller, Wibke A1 - Palm, Christoph T1 - Classification of Vascular Malformations Based on T2 STIR Magnetic Resonance Imaging T2 - Bildverarbeitung für die Medizin 2022: Proceedings, German Workshop on Medical Image Computing, Heidelberg, June 26-28, 2022 N2 - Vascular malformations (VMs) are a rare condition. They can be categorized into high-flow and low-flow VMs, which is a challenging task for radiologists. In this work, a very heterogeneous set of MRI images with only rough annotations are used for classification with a convolutional neural network. The main focus is to describe the challenging data set and strategies to deal with such data in terms of preprocessing, annotation usage and choice of the network architecture. We achieved a classification result of 89.47 % F1-score with a 3D ResNet 18. KW - Deep Learning KW - Magnetic Resonance Imaging KW - Vascular Malformations Y1 - 2022 U6 - https://doi.org/10.1007/978-3-658-36932-3_57 SP - 267 EP - 272 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Rauber, David A1 - Mendel, Robert A1 - Scheppach, Markus W. A1 - Ebigbo, Alanna A1 - Messmann, Helmut A1 - Palm, Christoph T1 - Analysis of Celiac Disease with Multimodal Deep Learning T2 - Bildverarbeitung für die Medizin 2022: Proceedings, German Workshop on Medical Image Computing, Heidelberg, June 26-28, 2022 N2 - Celiac disease is an autoimmune disorder caused by gluten that results in an inflammatory response of the small intestine.We investigated whether celiac disease can be detected using endoscopic images through a deep learning approach. The results show that additional clinical parameters can improve the classification accuracy. In this work, we distinguished between healthy tissue and Marsh III, according to the Marsh score system. We first trained a baseline network to classify endoscopic images of the small bowel into these two classes and then augmented the approach with a multimodality component that took the antibody status into account. KW - Deep Learning KW - Endoscopy Y1 - 2022 U6 - https://doi.org/10.1007/978-3-658-36932-3_25 SP - 115 EP - 120 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Weber, Joachim A1 - Brawanski, Alexander A1 - Palm, Christoph T1 - Parallelization of FSL-Fast segmentation of MRI brain data T2 - 58. Jahrestagung der Deutschen Gesellschaft für Medizinische Informatik, Biometrie und Epidemiologie e.V. (GMDS 2013), Lübeck, 01.-05.09.2013 Y1 - 2013 U6 - https://doi.org/10.3205/13gmds261 N1 - Meeting Abstract IS - DocAbstr. 329 PB - German Medical Science GMS Publishing House CY - Düsseldorf ER - TY - CHAP A1 - Palm, Christoph A1 - Siegmund, Heiko A1 - Semmelmann, Matthias A1 - Grafe, Claudia A1 - Evert, Matthias A1 - Schroeder, Josef A. T1 - Interactive Computer-assisted Approach for Evaluation of Ultrastructural Cilia Abnormalities T2 - Medical Imaging 2016: Computer-Aided Diagnosis, San Diego, California, United States, 27 February - 3 March, SPIE Proceedings 97853N, 2016, ISBN 9781510600201 N2 - Introduction – Diagnosis of abnormal cilia function is based on ultrastructural analysis of axoneme defects, especialy the features of inner and outer dynein arms which are the motors of ciliar motility. Sub-optimal biopsy material, methodical, and intrinsic electron microscopy factors pose difficulty in ciliary defects evaluation. We present a computer-assisted approach based on state-of-the-art image analysis and object recognition methods yielding a time-saving and efficient diagnosis of cilia dysfunction. Method – The presented approach is based on a pipeline of basal image processing methods like smoothing, thresholding and ellipse fitting. However, integration of application specific knowledge results in robust segmentations even in cases of image artifacts. The method is build hierarchically starting with the detection of cilia within the image, followed by the detection of nine doublets within each analyzable cilium, and ending with the detection of dynein arms of each doublet. The process is concluded by a rough classification of the dynein arms as basis for a computer-assisted diagnosis. Additionally, the interaction possibilities are designed in a way, that the results are still reproducible given the completion report. Results – A qualitative evaluation showed reasonable detection results for cilia, doublets and dynein arms. However, since a ground truth is missing, the variation of the computer-assisted diagnosis should be within the subjective bias of human diagnosticians. The results of a first quantitative evaluation with five human experts and six images with 12 analyzable cilia showed, that with default parameterization 91.6% of the cilia and 98% of the doublets were found. The computer-assisted approach rated 66% of those inner and outer dynein arms correct, where all human experts agree. However, especially the quality of the dynein arm classification may be improved in future work. KW - Image analysis KW - Image processing KW - Computer aided diagnosis and therapy KW - Image classification KW - Image segmentation KW - Biopsy KW - Electron microscopy KW - Zilie KW - Ultrastruktur KW - Anomalie KW - Bildverarbeitung KW - Objekterkennung KW - Computerunterstütztes Verfahren Y1 - 2016 U6 - https://doi.org/10.1117/12.2214976 ER - TY - JOUR A1 - Hutterer, Markus A1 - Hattingen, Elke A1 - Palm, Christoph A1 - Proescholdt, Martin Andreas A1 - Hau, Peter T1 - Current standards and new concepts in MRI and PET response assessment of antiangiogenic therapies in high-grade glioma patients JF - Neuro-Oncology N2 - Despite multimodal treatment, the prognosis of high-grade gliomas is grim. As tumor growth is critically dependent on new blood vessel formation, antiangiogenic treatment approaches offer an innovative treatment strategy. Bevacizumab, a humanized monoclonal antibody, has been in the spotlight of antiangiogenic approaches for several years. Currently, MRI including contrast-enhanced T1-weighted and T2/fluid-attenuated inversion recovery (FLAIR) images is routinely used to evaluate antiangiogenic treatment response (Response Assessment in Neuro-Oncology criteria). However, by restoring the blood–brain barrier, bevacizumab may reduce T1 contrast enhancement and T2/FLAIR hyperintensity, thereby obscuring the imaging-based detection of progression. The aim of this review is to highlight the recent role of imaging biomarkers from MR and PET imaging on measurement of disease progression and treatment effectiveness in antiangiogenic therapies. Based on the reviewed studies, multimodal imaging combining standard MRI with new physiological MRI techniques and metabolic PET imaging, in particular amino acid tracers, may have the ability to detect antiangiogenic drug susceptibility or resistance prior to morphological changes. As advances occur in the development of therapies that target specific biochemical or molecular pathways and alter tumor physiology in potentially predictable ways, the validation of physiological and metabolic imaging biomarkers will become increasingly important in the near future. KW - High-grade glioma KW - Antiangiogenic treatment KW - MRI KW - PET KW - Multimodal response assessment KW - Gliom KW - Antiangiogenese KW - Bildgebendes Verfahren KW - Biomarker Y1 - 2015 U6 - https://doi.org/10.1093/neuonc/nou322 VL - 17 IS - 6 SP - 784 EP - 800 ER - TY - CHAP A1 - Mendel, Robert A1 - Rauber, David A1 - Palm, Christoph T1 - Exploring the Effects of Contrastive Learning on Homogeneous Medical Image Data T2 - Bildverarbeitung für die Medizin 2023: Proceedings, German Workshop on Medical Image Computing, July 2– 4, 2023, Braunschweig N2 - We investigate contrastive learning in a multi-task learning setting classifying and segmenting early Barrett’s cancer. How can contrastive learning be applied in a domain with few classes and low inter-class and inter-sample variance, potentially enabling image retrieval or image attribution? We introduce a data sampling strategy that mines per-lesion data for positive samples and keeps a queue of the recent projections as negative samples. We propose a masking strategy for the NT-Xent loss that keeps the negative set pure and removes samples from the same lesion. We show cohesion and uniqueness improvements of the proposed method in feature space. The introduction of the auxiliary objective does not affect the performance but adds the ability to indicate similarity between lesions. Therefore, the approach could enable downstream auto-documentation tasks on homogeneous medical image data. Y1 - 2023 U6 - https://doi.org/10.1007/978-3-658-41657-7 SP - 128 EP - 13 PB - Springer Vieweg CY - Wiesbaden ER - TY - GEN A1 - Mendel, Robert A1 - Souza Jr., Luis Antonio de A1 - Rauber, David A1 - Papa, João Paulo A1 - Palm, Christoph T1 - Abstract: Semi-supervised Segmentation Based on Error-correcting Supervision T2 - Bildverarbeitung für die Medizin 2021. Proceedings, German Workshop on Medical Image Computing, Regensburg, March 7-9, 2021 N2 - Pixel-level classification is an essential part of computer vision. For learning from labeled data, many powerful deep learning models have been developed recently. In this work, we augment such supervised segmentation models by allowing them to learn from unlabeled data. Our semi-supervised approach, termed Error-Correcting Supervision, leverages a collaborative strategy. Apart from the supervised training on the labeled data, the segmentation network is judged by an additional network. KW - Deep Learning Y1 - 2021 SN - 978-3-658-33197-9 U6 - https://doi.org/10.1007/978-3-658-33198-6_43 SP - 178 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Ebigbo, Alanna A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Barrett esophagus: What to expect from Artificial Intelligence? JF - Best Practice & Research Clinical Gastroenterology N2 - The evaluation and assessment of Barrett’s esophagus is challenging for both expert and nonexpert endoscopists. However, the early diagnosis of cancer in Barrett’s esophagus is crucial for its prognosis, and could save costs. Pre-clinical and clinical studies on the application of Artificial Intelligence (AI) in Barrett’s esophagus have shown promising results. In this review, we focus on the current challenges and future perspectives of implementing AI systems in the management of patients with Barrett’s esophagus. KW - Deep Learning KW - Künstliche Intelligenz KW - Computerunterstützte Medizin KW - Barrett KW - Adenocarcinoma KW - Artificial intelligence KW - Deep learning KW - Convolutional neural networks Y1 - 2021 U6 - https://doi.org/10.1016/j.bpg.2021.101726 SN - 1521-6918 VL - 52-53 IS - June-August PB - Elsevier ER - TY - JOUR A1 - Maier, Andreas A1 - Deserno, Thomas M. A1 - Handels, Heinz A1 - Maier-Hein, Klaus H. A1 - Palm, Christoph A1 - Tolxdorff, Thomas T1 - Guest editorial of the IJCARS - BVM 2018 special issue JF - International Journal of Computer Assisted Radiology and Surgery KW - Medical Image Computing Y1 - 2019 U6 - https://doi.org/10.1007/s11548-018-01902-0 VL - 14 SP - 1 EP - 2 PB - Springer ER - TY - JOUR A1 - Passos, Leandro A. A1 - Souza Jr., Luis Antonio de A1 - Mendel, Robert A1 - Ebigbo, Alanna A1 - Probst, Andreas A1 - Messmann, Helmut A1 - Palm, Christoph A1 - Papa, João Paulo T1 - Barrett's esophagus analysis using infinity Restricted Boltzmann Machines JF - Journal of Visual Communication and Image Representation N2 - The number of patients with Barret’s esophagus (BE) has increased in the last decades. Considering the dangerousness of the disease and its evolution to adenocarcinoma, an early diagnosis of BE may provide a high probability of cancer remission. However, limitations regarding traditional methods of detection and management of BE demand alternative solutions. As such, computer-aided tools have been recently used to assist in this problem, but the challenge still persists. To manage the problem, we introduce the infinity Restricted Boltzmann Machines (iRBMs) to the task of automatic identification of Barrett’s esophagus from endoscopic images of the lower esophagus. Moreover, since iRBM requires a proper selection of its meta-parameters, we also present a discriminative iRBM fine-tuning using six meta-heuristic optimization techniques. We showed that iRBMs are suitable for the context since it provides competitive results, as well as the meta-heuristic techniques showed to be appropriate for such task. KW - Speiseröhrenkrankheit KW - Diagnose KW - Boltzmann-Maschine KW - Barrett’s esophagus KW - Infinity Restricted Boltzmann Machines KW - Meta-heuristics KW - Deep learning KW - Metaheuristik KW - Maschinelles Lernen Y1 - 2019 U6 - https://doi.org/10.1016/j.jvcir.2019.01.043 VL - 59 SP - 475 EP - 485 PB - Elsevier ER - TY - CHAP A1 - Souza Jr., Luis Antonio de A1 - Afonso, Luis Claudio Sugi A1 - Palm, Christoph A1 - Papa, João Paulo T1 - Barrett's Esophagus Identification Using Optimum-Path Forest T2 - Proceedings of the 30th Conference on Graphics, Patterns and Images Tutorials (SIBGRAPI-T 2017), Niterói, Rio de Janeiro, Brazil, 2017, 17-20 October N2 - Computer-assisted analysis of endoscopic images can be helpful to the automatic diagnosis and classification of neoplastic lesions. Barrett's esophagus (BE) is a common type of reflux that is not straight forward to be detected by endoscopic surveillance, thus being way susceptible to erroneous diagnosis, which can cause cancer when not treated properly. In this work, we introduce the Optimum-Path Forest (OPF) classifier to the task of automatic identification of Barrett'sesophagus, with promising results and outperforming the well known Support Vector Machines (SVM) in the aforementioned context. We consider describing endoscopic images by means of feature extractors based on key point information, such as the Speeded up Robust Features (SURF) and Scale-Invariant Feature Transform (SIFT), for further designing a bag-of-visual-wordsthat is used to feed both OPF and SVM classifiers. The best results were obtained by means of the OPF classifier for both feature extractors, with values lying on 0.732 (SURF) - 0.735(SIFT) for sensitivity, 0.782 (SURF) - 0.806 (SIFT) for specificity, and 0.738 (SURF) - 0.732 (SIFT) for the accuracy. KW - Speiseröhrenkrankheit KW - Diagnose KW - Maschinelles Lernen KW - Bilderkennung KW - Automatische Klassifikation Y1 - 2017 U6 - https://doi.org/10.1109/SIBGRAPI.2017.47 SP - 308 EP - 314 ER - TY - CHAP A1 - Zehner, Alexander A1 - Szalo, Alexander Eduard A1 - Palm, Christoph T1 - GraphMIC: Easy Prototyping of Medical Image Computing Applications T2 - Interactive Medical Image Computing (IMIC), Workshop at the Medical Image Computing and Computer Assisted Interventions (MICCAI 2015), 2015, Munich N2 - GraphMIC is a cross-platform image processing application utilizing the libraries ITK and OpenCV. The abstract structure of image processing pipelines is visually represented by user interface components based on modern QtQuick technology and allows users to focus on arrangement and parameterization of operations rather than implementing the equivalent functionality natively in C++. The application's central goal is to improve and simplify the typical workflow by providing various high level features and functions like multi threading, image sequence processing and advanced error handling. A built-in python interpreter allows the creation of custom nodes, where user defined algorithms can be integrated to extend basic functionality. An embedded 2d/3d visual-izer gives feedback of the resulting image of an operation or the whole pipeline. User inputs like seed points, contours or regions are forwarded to the processing pipeline as parameters to offer semi-automatic image computing. We report the main concept of the application and introduce several features and their implementation. Finally, the current state of development as well as future perspectives of GraphMIC are discussed KW - Bildverarbeitung KW - Medizin Y1 - 2015 U6 - https://doi.org/10.13140/RG.2.1.3718.4725 N1 - Open-Access-Publikation SP - 395 EP - 400 ER - TY - CHAP A1 - Weber, Joachim A1 - Doenitz, Christian A1 - Brawanski, Alexander A1 - Palm, Christoph T1 - Data-Parallel MRI Brain Segmentation in Clinicial Use BT - Porting FSL-Fastv4 to GPGPUs T2 - Bildverarbeitung für die Medizin 2015; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 15. bis 17. März 2015 in Lübeck N2 - Structural MRI brain analysis and segmentation is a crucial part in the daily routine in neurosurgery for intervention planning. Exemplarily, the free software FSL-FAST (FMRIB’s Segmentation Library – FMRIB’s Automated Segmentation Tool) in version 4 is used for segmentation of brain tissue types. To speed up the segmentation procedure by parallel execution, we transferred FSL-FAST to a General Purpose Graphics Processing Unit (GPGPU) using Open Computing Language (OpenCL) [1]. The necessary steps for parallelization resulted in substantially different and less useful results. Therefore, the underlying methods were revised and adapted yielding computational overhead. Nevertheless, we achieved a speed-up factor of 3.59 from CPU to GPGPU execution, as well providing similar useful or even better results. KW - Brain Segmentation KW - Magnetic Resonance Imaging KW - Parallel Execution KW - Voxel Spacing KW - General Purpose Graphic Processing Unit KW - Kernspintomografie KW - Gehirn KW - Bildsegmentierung KW - Parallelverarbeitung Y1 - 2015 U6 - https://doi.org/10.1007/978-3-662-46224-9_67 SP - 389 EP - 394 PB - Springer CY - Berlin ER - TY - GEN A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph ED - Handels, Heinz ED - Deserno, Thomas M. ED - Maier, Andreas ED - Maier-Hein, Klaus H. ED - Palm, Christoph ED - Tolxdorff, Thomas T1 - Abstract: Imitating Human Soft Tissue with Dual-Material 3D Printing T2 - Bildverarbeitung für die Medizin 2019, Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 17. bis 19. März 2019 in Lübeck N2 - Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. KW - Handchirurgie KW - 3D-Druck KW - Lernprogramm KW - HaptiVisT Y1 - 2019 SN - 978-3-658-25325-7 U6 - https://doi.org/10.1007/978-3-658-25326-4_48 SP - 218 PB - Springer Vieweg CY - Wiesbaden ER - TY - GEN A1 - Rückert, Tobias A1 - Rieder, Maximilian A1 - Rauber, David A1 - Xiao, Michel A1 - Humolli, Eg A1 - Feussner, Hubertus A1 - Wilhelm, Dirk A1 - Palm, Christoph T1 - Augmenting instrument segmentation in video sequences of minimally invasive surgery by synthetic smoky frames T2 - International Journal of Computer Assisted Radiology and Surgery KW - Surgical instrument segmentation KW - smoke simulation KW - unpaired image-to-image translation KW - robot-assisted surgery Y1 - 2023 U6 - https://doi.org/10.1007/s11548-023-02878-2 VL - 18 IS - Suppl 1 SP - S54 EP - S56 PB - Springer Nature ER - TY - JOUR A1 - Maerkl, Raphaela A1 - Rueckert, Tobias A1 - Rauber, David A1 - Gutbrod, Max A1 - Weber Nunes, Danilo A1 - Palm, Christoph T1 - Enhancing generalization in zero-shot multi-label endoscopic instrument classification JF - International Journal of Computer Assisted Radiology and Surgery N2 - Purpose Recognizing previously unseen classes with neural networks is a significant challenge due to their limited generalization capabilities. This issue is particularly critical in safety-critical domains such as medical applications, where accurate classification is essential for reliability and patient safety. Zero-shot learning methods address this challenge by utilizing additional semantic data, with their performance relying heavily on the quality of the generated embeddings. Methods This work investigates the use of full descriptive sentences, generated by a Sentence-BERT model, as class representations, compared to simpler category-based word embeddings derived from a BERT model. Additionally, the impact of z-score normalization as a post-processing step on these embeddings is explored. The proposed approach is evaluated on a multi-label generalized zero-shot learning task, focusing on the recognition of surgical instruments in endoscopic images from minimally invasive cholecystectomies. Results The results demonstrate that combining sentence embeddings and z-score normalization significantly improves model performance. For unseen classes, the AUROC improves from 43.9% to 64.9%, and the multi-label accuracy from 26.1% to 79.5%. Overall performance measured across both seen and unseen classes improves from 49.3% to 64.9% in AUROC and from 37.3% to 65.1% in multi-label accuracy, highlighting the effectiveness of our approach. Conclusion These findings demonstrate that sentence embeddings and z-score normalization can substantially enhance the generalization performance of zero-shot learning models. However, as the study is based on a single dataset, future work should validate the method across diverse datasets and application domains to establish its robustness and broader applicability. KW - Generalized zero-shot learning KW - Sentence embeddings KW - Z-score normalization KW - Multi-label classification KW - Surgical instruments Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-85674 N1 - Corresponding author der OTH Regensburg: Raphaela Maerkl VL - 20 SP - 1577 EP - 1587 PB - Springer Nature ER - TY - GEN A1 - Scheppach, Markus W. A1 - Weber Nunes, Danilo A1 - Rauber, David A1 - Arizi, X. A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Ebigbo, Alanna A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Künstliche Intelligenz-basierte Erkennung von interventionellen Phasen bei der endoskopischen Submukosadissektion T2 - Zeitschrift für Gastroenterologie N2 - Einleitung: Die endoskopische Submukosadissektion (ESD) ist ein komplexes endoskopisches Verfahren, das technische Expertise erfordert. Objektive Methoden zur Analyse von interventionellen Abläufen bei ESD könnten für Qualitätssicherung und Ausbildung, wie auch eine automatische Befunderstellung von Nutzen sein. Ziele: In dieser Studie wurde ein KI-Algorithmus für die Erkennung und Klassifizierung der interventionellen Phasen der ESD entwickelt, um die technische Basis für eine standardisierte Leistungsbewertung und automatische Befunderstellung zu schaffen. Methodik: Vollständige ESD-Videoaufnahmen von 49 Patienten wurden retrospektiv zusammengestellt. Der Datensatz umfasste 6.390.151 Einzelbilder, die alle für die folgenden interventionellen Phasen annotiert wurden: Diagnostik, Markierung, Injektion, Dissektion und Hämostase. 3.973.712 Bilder (28 Patienten) wurden für das Training eines Video-Swin-Transformers genutzt. Dabei wurde temporale Information durch standardisierte BIldextraktion in festgelegten zeitlichen Abständen zum analysierten Bild inkorporiert. 2.416.439 separate Bilder (21 Patienten) wurden für eine interne Validierung genutzt. Ergebnis: Bei der internen Evaluation erreichte das System insgesamt einen F1-Wert von 0,88. Es wurden F1-Werte von 0,99, 0,89, 0,89, 0,91 und 0,52 für Diagnostik, Markierung, Injektion, Dissektion bzw. Blutungsmanagement gemessen. Die Sensitivitäten für dieselben Parameter betrugen 1,00, 0,80, 0,94, 0,89 und 0,67, die Spezifitäten lagen bei 1,00, 1,00, 0,98, 0,88 und 0,93. Positive prädiktive Werte wurden mit 0,98, 1,00, 0,85, 0,94 und 0,43 gemessen. Schlussfolgerung: In dieser vorläufigen Studie zeigte ein KI-Algorithmus eine hohe Leistungsfähigkeit für die Einzelbild-Erkennung von Verfahrensphasen während der ESD. Die vergleichsweise niedrige Leistung für die Blutungsphase wurde auf das seltene Auftreten von Blutungsepisoden im Trainingsdatensatz zurückgeführt, der zu diesem Zeitpunkt nur Videos in voller Länge umfasste. Die zukünftige Entwicklung des Algorithmus wird sich auf die Reduzierung von Klassenungleichgewichten durch selektive Annotationsprotokolle konzentrieren. Y1 - 2025 U6 - https://doi.org/10.1055/s-0045-1811093 VL - 63 IS - 08 SP - e612 EP - e613 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Scheppach, Markus W. A1 - Rauber, David A1 - Zingler, C. A1 - Weber Nunes, Danilo A1 - Probst, Andreas A1 - Römmele, Christoph A1 - Nagl, Sandra A1 - Ebigbo, Alanna A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Instrumentenerkennung während der endoskopischen Submukosadissektion mittels künstlicher Intelligenz T2 - Zeitschrift für Gastroenterologie N2 - Einleitung: Die endoskopische Submukosadissektion (ESD) ist eine komplexe Technik zur Resektion gastrointestinaler Frühneoplasien. Dabei werden für die verschiedenen Schritte der Intervention spezifische endoskopische Instrumente verwendet. Die präzise und automatische Erkennung und Abgrenzung der verwendeten Instrumente (Injektionsnadeln, elektrochirurgische Messer mit unterschiedlichen Konfigurationen, hämostatische Zangen) könnte wertvolle Informationen über den Fortschritt und die Verfahrensmerkmale der ESD liefern und eine automatische standardisierte Berichterstattung ermöglichen. Ziele: Ziel dieser Studie war die Entwicklung eines KI-Algorithmus zur Erkennung und Delineation von endoskopischen Instrumenten bei der ESD. Methodik: 17 ESD-Videos (9×rektal, 5×ösophageal, 3×gastrisch) wurden retrospektiv zusammengestellt. Auf 8530 Einzelbilder dieser Videos wurden durch 2 Studienmitarbeiter die folgenden Klassen eingezeichnet: Hakenmesser – Spitze, Hakenmesser – Katheter, Nadelmesser – Spitze und – Katheter, Injektionsnadel -Spitze und – Katheter sowie hämostatische Zange – Spitze und – Katheter. Der annotierte Datensatz wurde zum Training eines DeepLabV3+-Deep-Learning-Algorithmus mit ConvNeXt-Backbone zur Erkennung und Abgrenzung der genannten Klassen verwendet. Die Evaluation erfolgte durch 5-fache interne Kreuzvalidierung. Ergebnis: Die Validierung auf Einzelpixelbasis ergab insgesamt einen F1-Score von 0,80, eine Sensitivität von 0,81 und eine Spezifität von 1,00. Es wurden F1-Scores von 1,00, 0,97, 0,80, 0,98, 0,85, 0,97, 0,80, 0,51 bzw. 0,85 für die Klassen Hakenmesser – Katheter und – Spitze, Nadelmesser – Katheter und – Spitze, Injektionsnadel – Katheter und – Spitze, hämostatische Zange – Katheter und – Spitze gemessen. Schlussfolgerung: In dieser Studie wurden die wichtigsten endoskopischen Instrumente, die während der ESD verwendet werden, mit hoher Genauigkeit erkannt. Die geringere Leistung bei der hämostatische Zange – Katheter kann auf die Unterrepräsentation dieser Klassen in den Trainingsdaten zurückgeführt werden. Zukünftige Studien werden sich auf die Erweiterung der Instrumentenklassen sowie auf die Ausbalancierung der Trainingsdaten konzentrieren. Y1 - 2025 U6 - https://doi.org/10.1055/s-0045-1811092 VL - 63 IS - 8 PB - Thieme ER - TY - CHAP A1 - Klausmann, Leonard A1 - Rueckert, Tobias A1 - Rauber, David A1 - Maerkl, Raphaela A1 - Yildiran, Suemeyye R. A1 - Gutbrod, Max A1 - Palm, Christoph T1 - DIY challenge blueprint: from organization to technical realization in biomedical image analysis T2 - Medical Image Computing and Computer Assisted Intervention - MICCAI 2025 ; Proceedings Part XI N2 - Biomedical image analysis challenges have become the de facto standard for publishing new datasets and benchmarking different state-of-the-art algorithms. Most challenges use commercial cloud-based platforms, which can limit custom options and involve disadvantages such as reduced data control and increased costs for extended functionalities. In contrast, Do-It-Yourself (DIY) approaches have the capability to emphasize reliability, compliance, and custom features, providing a solid basis for low-cost, custom designs in self-hosted systems. Our approach emphasizes cost efficiency, improved data sovereignty, and strong compliance with regulatory frameworks, such as the GDPR. This paper presents a blueprint for DIY biomedical imaging challenges, designed to provide institutions with greater autonomy over their challenge infrastructure. Our approach comprehensively addresses both organizational and technical dimensions, including key user roles, data management strategies, and secure, efficient workflows. Key technical contributions include a modular, containerized infrastructure based on Docker, integration of open-source identity management, and automated solution evaluation workflows. Practical deployment guidelines are provided to facilitate implementation and operational stability. The feasibility and adaptability of the proposed framework are demonstrated through the MICCAI 2024 PhaKIR challenge with multiple international teams submitting and validating their solutions through our self-hosted platform. This work can be used as a baseline for future self-hosted DIY implementations and our results encourage further studies in the area of biomedical image analysis challenges. KW - Biomedical challenges KW - Image analysis KW - Blueprint KW - Do-It-Yourself KW - Self-hosting Y1 - 2025 SN - 978-3-032-05141-7 U6 - https://doi.org/10.1007/978-3-032-05141-7_9 SP - 85 EP - 95 PB - Springer CY - Cham ER - TY - INPR A1 - Gutbrod, Max A1 - Rauber, David A1 - Weber Nunes, Danilo A1 - Palm, Christoph T1 - OpenMIBOOD: Open Medical Imaging Benchmarks for Out-Of-Distribution Detection N2 - The growing reliance on Artificial Intelligence (AI) in critical domains such as healthcare demands robust mechanisms to ensure the trustworthiness of these systems, especially when faced with unexpected or anomalous inputs. This paper introduces the Open Medical Imaging Benchmarks for Out-Of-Distribution Detection (OpenMIBOOD), a comprehensive framework for evaluating out-of-distribution (OOD) detection methods specifically in medical imaging contexts. OpenMIBOOD includes three benchmarks from diverse medical domains, encompassing 14 datasets divided into covariate-shifted in-distribution, near-OOD, and far-OOD categories. We evaluate 24 post-hoc methods across these benchmarks, providing a standardized reference to advance the development and fair comparison of OOD detection methods. Results reveal that findings from broad-scale OOD benchmarks in natural image domains do not translate to medical applications, underscoring the critical need for such benchmarks in the medical field. By mitigating the risk of exposing AI models to inputs outside their training distribution, OpenMIBOOD aims to support the advancement of reliable and trustworthy AI systems in healthcare. The repository is available at this https URL. Y1 - 2025 U6 - https://doi.org/10.48550/arXiv.2503.16247 N1 - Der Aufsatz wurde peer-reviewed veröffentlicht und ist ebenfalls in diesem Repositorium verzeichnet unter: https://opus4.kobv.de/opus4-oth-regensburg/8467 ER - TY - JOUR A1 - Weiherer, Maximilian A1 - Eigenberger, Andreas A1 - Egger, Bernhard A1 - Brébant, Vanessa A1 - Prantl, Lukas A1 - Palm, Christoph T1 - Learning the shape of female breasts: an open-access 3D statistical shape model of the female breast built from 110 breast scans JF - The Visual Computer N2 - We present the Regensburg Breast Shape Model (RBSM)—a 3D statistical shape model of the female breast built from 110 breast scans acquired in a standing position, and the first publicly available. Together with the model, a fully automated, pairwise surface registration pipeline used to establish dense correspondence among 3D breast scans is introduced. Our method is computationally efficient and requires only four landmarks to guide the registration process. A major challenge when modeling female breasts from surface-only 3D breast scans is the non-separability of breast and thorax. In order to weaken the strong coupling between breast and surrounding areas, we propose to minimize the variance outside the breast region as much as possible. To achieve this goal, a novel concept called breast probability masks (BPMs) is introduced. A BPM assigns probabilities to each point of a 3D breast scan, telling how likely it is that a particular point belongs to the breast area. During registration, we use BPMs to align the template to the target as accurately as possible inside the breast region and only roughly outside. This simple yet effective strategy significantly reduces the unwanted variance outside the breast region, leading to better statistical shape models in which breast shapes are quite well decoupled from the thorax. The RBSM is thus able to produce a variety of different breast shapes as independently as possible from the shape of the thorax. Our systematic experimental evaluation reveals a generalization ability of 0.17 mm and a specificity of 2.8 mm. To underline the expressiveness of the proposed model, we finally demonstrate in two showcase applications how the RBSM can be used for surgical outcome simulation and the prediction of a missing breast from the remaining one. Our model is available at https://www.rbsm.re-mic.de/. KW - Statistical shape model KW - Non-rigid surface registration KW - Breast imaging KW - Surgical outcome simulation KW - Breast reconstruction surgery Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-30506 N1 - Corresponding author: Christoph Palm N1 - Zugehörige arXiv-Publikation: https://opus4.kobv.de/opus4-oth-regensburg/frontdoor/index/index/docId/2023 VL - 39 IS - 4 SP - 1597 EP - 1616 PB - Springer Nature ER - TY - JOUR A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph T1 - Imitating human soft tissue on basis of a dual-material 3D print using a support-filled metamaterial to provide bimanual haptic for a hand surgery training system JF - Quantitative Imaging in Medicine and Surgery N2 - Background: Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D-printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. Methods: The goal of this experiment is to imitate human soft tissue with its haptic and elasticity for a realistic hand phantom fabrication, using only a dual-material 3D printer and support-material-filled metamaterial between skin and bone. We present our workflow to generate lattice structures between hard bone and soft skin with iterative cube edge (CE) or cube face (CF) unit cells. Cuboid and finger shaped sample prints with and without inner hard bone in different lattice thickness are constructed and 3D printed. Results: The most elastic available rubber-like material is too firm to imitate soft tissue. By reducing the amount of rubber in the inner volume through support material (SUP), objects become significantly softer. Without metamaterial, after disintegration, the SUP can be shifted through the volume and thus the body loses its original shape. Although the CE design increases the elasticity, it cannot restore the fabric form. In contrast to CE, the CF design increases not only the elasticity but also guarantees a local limitation of the SUP. Therefore, the body retains its shape and internal bones remain in its intended place. Various unit cell sizes, lattice thickening and skin thickness regulate the rubber material and SUP ratio. Test prints with higher SUP and lower rubber material percentage appear softer and vice versa. This was confirmed by an expert surgeon evaluation. Subjects adjudged pure rubber-like material as too firm and samples only filled with SUP or lattice structure in CE design as not suitable for imitating tissue. 3D-printed finger samples in CF design were rated as realistic compared to the haptic of human tissue with a good palpable bone structure. Conclusions: We developed a new dual-material 3D print technique to imitate soft tissue of the human hand with its haptic properties. Blowy SUP is trapped within a lattice structure to soften rubber-like 3D print material, which makes it possible to reproduce a realistic replica of human hand soft tissue. KW - Dual-material 3D printing KW - Hand surgery training KW - Metamaterial KW - Support material KW - Tissue-imitating hand phantom KW - Handchirurgie KW - 3D-Druck KW - Biomaterial KW - Lernprogramm Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-979 N1 - Corresponding author: Christoph Palm VL - 9 IS - 1 SP - 30 EP - 42 PB - AME Publishing Company ER - TY - JOUR A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph T1 - Optically tracked and 3D printed haptic phantom hand for surgical training system JF - Quantitative Imaging in Medicine and Surgery N2 - Background: For surgical fixation of bone fractures of the human hand, so-called Kirschner-wires (K-wires) are drilled through bone fragments. Due to the minimally invasive drilling procedures without a view of risk structures like vessels and nerves, a thorough training of young surgeons is necessary. For the development of a virtual reality (VR) based training system, a three-dimensional (3D) printed phantom hand is required. To ensure an intuitive operation, this phantom hand has to be realistic in both, its position relative to the driller as well as in its haptic features. The softest 3D printing material available on the market, however, is too hard to imitate human soft tissue. Therefore, a support-material (SUP) filled metamaterial is used to soften the raw material. Realistic haptic features are important to palpate protrusions of the bone to determine the drilling starting point and angle. An optical real-time tracking is used to transfer position and rotation to the training system. Methods: A metamaterial already developed in previous work is further improved by use of a new unit cell. Thus, the amount of SUP within the volume can be increased and the tissue is softened further. In addition, the human anatomy is transferred to the entire hand model. A subcutaneous fat layer and penetration of air through pores into the volume simulate shiftability of skin layers. For optical tracking, a rotationally symmetrical marker attached to the phantom hand with corresponding reference marker is developed. In order to ensure trouble-free position transmission, various types of marker point applications are tested. Results: Several cuboid and forearm sample prints lead to a final 30 centimeter long hand model. The whole haptic phantom could be printed faultless within about 17 hours. The metamaterial consisting of the new unit cell results in an increased SUP share of 4.32%. Validated by an expert surgeon study, this allows in combination with a displacement of the uppermost skin layer a good palpability of the bones. Tracking of the hand marker in dodecahedron design works trouble-free in conjunction with a reference marker attached to the worktop of the training system. Conclusions: In this work, an optically tracked and haptically correct phantom hand was developed using dual-material 3D printing, which can be easily integrated into a surgical training system. KW - Handchirurgie KW - 3D-Druck KW - Lernprogramm KW - Zielverfolgung KW - HaptiVisT KW - Dual-material 3D printing KW - hand surgery training KW - metamaterial KW - tissue imitating phantom hand Y1 - 2020 U6 - https://doi.org/10.21037/qims.2019.12.03 N1 - Corresponding author: Christoph Palm VL - 10 IS - 02 SP - 340 EP - 455 PB - AME Publishing Company CY - Hong Kong, China ER - TY - CHAP A1 - Franz, Daniela A1 - Dreher, Maria A1 - Prinzen, Martin A1 - Teßmann, Matthias A1 - Palm, Christoph A1 - Katzky, Uwe A1 - Perret, Jerome A1 - Hofer, Mathias A1 - Wittenberg, Thomas T1 - CT-basiertes virtuelles Fräsen am Felsenbein BT - Bild- und haptischen Wiederholfrequenzen bei unterschiedlichen Rendering Methoden T2 - Bildverarbeitung für die Medizin 2018; Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 11. bis 13. März 2018 in Erlangen N2 - Im Rahmen der Entwicklung eines haptisch-visuellen Trainingssystems für das Fräsen am Felsenbein werden ein Haptikarm und ein autostereoskopischer 3D-Monitor genutzt, um Chirurgen die virtuelle Manipulation von knöchernen Strukturen im Kontext eines sog. Serious Game zu ermöglichen. Unter anderem sollen Assistenzärzte im Rahmen ihrer Ausbildung das Fräsen am Felsenbein für das chirurgische Einsetzen eines Cochlea-Implantats üben können. Die Visualisierung des virtuellen Fräsens muss dafür in Echtzeit und möglichst realistisch modelliert, implementiert und evaluiert werden. Wir verwenden verschiedene Raycasting Methoden mit linearer und Nearest Neighbor Interpolation und vergleichen die visuelle Qualität und die Bildwiederholfrequenzen der Methoden. Alle verglichenen Verfahren sind sind echtzeitfähig, unterscheiden sich aber in ihrer visuellen Qualität. KW - Felsenbein KW - Fräsen KW - Virtualisierung KW - Computertomographie KW - Computerassistierte Chirurgie Y1 - 2018 SN - 978-3-662-56537-7 U6 - https://doi.org/10.1007/978-3-662-56537-7_51 SP - 176 EP - 181 PB - Springer CY - Berlin ER - TY - CHAP A1 - Maier, Johannes A1 - Huber, Michaela A1 - Katzky, Uwe A1 - Perret, Jerome A1 - Wittenberg, Thomas A1 - Palm, Christoph T1 - Force-Feedback-assisted Bone Drilling Simulation Based on CT Data T2 - Bildverarbeitung für die Medizin 2018; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 11. bis 13. März 2018 in Erlangen N2 - In order to fix a fracture using minimally invasive surgery approaches, surgeons are drilling complex and tiny bones with a 2 dimensional X-ray as single imaging modality in the operating room. Our novel haptic force-feedback and visual assisted training system will potentially help hand surgeons to learn the drilling procedure in a realistic visual environment. Within the simulation, the collision detection as well as the interaction between virtual drill, bone voxels and surfaces are important. In this work, the chai3d collision detection and force calculation algorithms are combined with a physics engine to simulate the bone drilling process. The chosen Bullet-Physics-Engine provides a stable simulation of rigid bodies, if the collision model of the drill and the tool holder is generated as a compound shape. Three haptic points are added to the K-wire tip for removing single voxels from the bone. For the drilling process three modes are proposed to emulate the different phases of drilling in restricting the movement of a haptic device. KW - Handchirurgie KW - Osteosynthese KW - Simulation KW - Lernprogramm Y1 - 2018 U6 - https://doi.org/10.1007/978-3-662-56537-7_78 SP - 291 EP - 296 PB - Springer CY - Berlin ER - TY - CHAP A1 - Eixelberger, Thomas A1 - Wittenberg, Thomas A1 - Perret, Jerome A1 - Katzky, Uwe A1 - Simon, Martina A1 - Schmitt-Rüth, Stephanie A1 - Hofer, Mathias A1 - Sorge, M. A1 - Jacob, R. A1 - Engel, Felix B. A1 - Gostian, A. A1 - Palm, Christoph A1 - Franz, Daniela T1 - A haptic model for virtual petrosal bone milling T2 - 17. Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassistierte Chirurgie (CURAC2018), Tagungsband, 2018, Leipzig, 13.-15. September N2 - Virtual training of bone milling requires realtime and realistic haptics of the interaction between the ”virtual mill” and a ”virtual bone”. We propose an exponential abrasion model between a virtual one and the mill bit and combine it with a coarse representation of the virtual bone and the mill shaft for collision detection using the Bullet Physics Engine. We compare our exponential abrasion model to a widely used linear abrasion model and evaluate it quantitatively and qualitatively. The evaluation results show, that we can provide virtual milling in real-time, with an abrasion behavior similar to that proposed in the literature and with a realistic feeling of five different surgeons. KW - Osteosynthese KW - Simulation KW - Lernprogramm Y1 - 2018 UR - https://www.curac.org/images/advportfoliopro/images/CURAC2018/CURAC 2018 Tagungsband.pdf VL - 17 SP - 214 EP - 219 ER - TY - CHAP A1 - Palm, Christoph A1 - Schanze, Thomas T1 - Biomedical Image and Signal Computing (BISC 2013) T2 - 58. Jahrestagung der Deutschen Gesellschaft für Medizinische Informatik, Biometrie und Epidemiologie e.V. (GMDS 2013), Lübeck, 01.-05.09.2013 Y1 - 2013 U6 - https://doi.org/doi:10.3205/13gmds257 N1 - Meeting Abstract IS - DocAbstr. 324 PB - German Medical Science GMS Publishing House CY - Düsseldorf ER - TY - JOUR A1 - Ebigbo, Alanna A1 - Mendel, Robert A1 - Probst, Andreas A1 - Manzeneder, Johannes A1 - Souza Jr., Luis Antonio de A1 - Papa, João Paulo A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Computer-aided diagnosis using deep learning in the evaluation of early oesophageal adenocarcinoma JF - GuT N2 - Computer-aided diagnosis using deep learning (CAD-DL) may be an instrument to improve endoscopic assessment of Barrett’s oesophagus (BE) and early oesophageal adenocarcinoma (EAC). Based on still images from two databases, the diagnosis of EAC by CAD-DL reached sensitivities/specificities of 97%/88% (Augsburg data) and 92%/100% (Medical Image Computing and Computer-Assisted Intervention [MICCAI] data) for white light (WL) images and 94%/80% for narrow band images (NBI) (Augsburg data), respectively. Tumour margins delineated by experts into images were detected satisfactorily with a Dice coefficient (D) of 0.72. This could be a first step towards CAD-DL for BE assessment. If developed further, it could become a useful adjunctive tool for patient management. KW - Speiseröhrenkrebs KW - Diagnose KW - Computerunterstütztes Verfahren KW - Maschinelles Lernen Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-68 N1 - Corresponding authors: Alanna Ebigbo and Christoph Palm VL - 68 IS - 7 SP - 1143 EP - 1145 PB - British Society of Gastroenterology ER - TY - JOUR A1 - Wöhl, Rebecca A1 - Maier, Johannes A1 - Gehmert, Sebastian A1 - Palm, Christoph A1 - Riebschläger, Birgit A1 - Nerlich, Michael A1 - Huber, Michaela T1 - 3D Analysis of Osteosyntheses Material using semi-automated CT Segmentation BT - a case series of a 4 corner fusion plate JF - BMC Musculoskeletal Disorders N2 - Backround Scaphoidectomy and midcarpal fusion can be performed using traditional fixation methods like K-wires, staples, screws or different dorsal (non)locking arthrodesis systems. The aim of this study is to test the Aptus four corner locking plate and to compare the clinical findings to the data revealed by CT scans and semi-automated segmentation. Methods: This is a retrospective review of eleven patients suffering from scapholunate advanced collapse (SLAC) or scaphoid non-union advanced collapse (SNAC) wrist, who received a four corner fusion between August 2011 and July 2014. The clinical evaluation consisted of measuring the range of motion (ROM), strength and pain on a visual analogue scale (VAS). Additionally, the Disabilities of the Arm, Shoulder and Hand (QuickDASH) and the Mayo Wrist Score were assessed. A computerized tomography (CT) of the wrist was obtained six weeks postoperatively. After semi-automated segmentation of the CT scans, the models were post processed and surveyed. Results During the six-month follow-up mean range of motion (ROM) of the operated wrist was 60°, consisting of 30° extension and 30° flexion. While pain levels decreased significantly, 54% of grip strength and 89% of pinch strength were preserved compared to the contralateral healthy wrist. Union could be detected in all CT scans of the wrist. While X-ray pictures obtained postoperatively revealed no pathology, two user related technical complications were found through the 3D analysis, which correlated to the clinical outcome. Conclusion Due to semi-automated segmentation and 3D analysis it has been proved that the plate design can keep up to the manufacturers’ promises. Over all, this case series confirmed that the plate can compete with the coexisting techniques concerning clinical outcome, union and complication rate. KW - Handchirurgie KW - Osteosynthese KW - Arthrodese KW - 4FC KW - SLAC wrist KW - SNAC wrist KW - Semi-automated segmentation KW - 3D analysis KW - Computertomographie KW - Bildsegmentierung KW - Dreidimensionale Bildverarbeitung Y1 - 2018 U6 - https://doi.org/10.1186/s12891-018-1975-0 VL - 19 SP - 1 EP - 8 PB - Springer Nature ER - TY - GEN A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Probst, Andreas A1 - Rauber, David A1 - Rückert, Tobias A1 - Meinikheim, Michael A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Real-time detection and delineation of tissue during third-space endoscopy using artificial intelligence (AI) T2 - Endoscopy N2 - Aims  AI has proven great potential in assisting endoscopists in diagnostics, however its role in therapeutic endoscopy remains unclear. Endoscopic submucosal dissection (ESD) is a technically demanding intervention with a slow learning curve and relevant risks like bleeding and perforation. Therefore, we aimed to develop an algorithm for the real-time detection and delineation of relevant structures during third-space endoscopy. Methods  5470 still images from 59 full length videos (47 ESD, 12 POEM) were annotated. 179681 additional unlabeled images were added to the training dataset. Consequently, a DeepLabv3+ neural network architecture was trained with the ECMT semi-supervised algorithm (under review elsewhere). Evaluation of vessel detection was performed on a dataset of 101 standardized video clips from 15 separate third-space endoscopy videos with 200 predefined blood vessels. Results  Internal validation yielded an overall mean Dice score of 85% (68% for blood vessels, 86% for submucosal layer, 88% for muscle layer). On the video test data, the overall vessel detection rate (VDR) was 94% (96% for ESD, 74% for POEM). The median overall vessel detection time (VDT) was 0.32 sec (0.3 sec for ESD, 0.62 sec for POEM). Conclusions  Evaluation of the developed algorithm on a video test dataset showed high VDR and quick VDT, especially for ESD. Further research will focus on a possible clinical benefit of the AI application for VDR and VDT during third-space endoscopy. KW - Speiseröhrenkrankheit KW - Künstliche Intelligenz KW - Artificial Intelligence Y1 - 2023 U6 - https://doi.org/10.1055/s-0043-1765128 VL - 55 IS - S02 SP - S53 EP - S54 PB - Thieme ER - TY - CHAP A1 - Franz, Daniela A1 - Katzky, Uwe A1 - Neumann, Sabine A1 - Perret, Jerome A1 - Hofer, Mathias A1 - Huber, Michaela A1 - Schmitt-Rüth, Stephanie A1 - Haug, Sonja A1 - Weber, Karsten A1 - Prinzen, Martin A1 - Palm, Christoph A1 - Wittenberg, Thomas T1 - Haptisches Lernen für Cochlea Implantationen BT - Konzept - HaptiVisT Projekt T2 - 15. Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassistierte Chirurgie (CURAC2016), Tagungsband, 2016, Bern, 29.09. - 01.10. N2 - Die Implantation eines Cochlea Implantates benötigt einen chirurgischen Zugang im Felsenbein und durch die Paukenhöhle des Patienten. Der Chirurg hat eine eingeschränkte Sicht im Operationsgebiet, die weiterhin viele Risikostrukturen enthält. Um eine Cochlea Implantation sicher und fehlerfrei durchzuführen, ist eine umfangreiche theoretische und praktische (teilweise berufsbegleitende) Fortbildung sowie langjährige Erfahrung notwendig. Unter Nutzung von realen klinischen CT/MRT Daten von Innen- und Mittelohr und der interaktiven Segmentierung der darin abgebildeten Strukturen (Nerven, Cochlea, Gehörknöchelchen,...) wird im HaptiVisT Projekt ein haptisch-visuelles Trainingssystem für die Implantation von Innen- und Mittelohr-Implantaten realisiert, das als sog. „Serious Game“ mit immersiver Didaktik gestaltet wird. Die Evaluierung des Demonstrators hinsichtlich Zweckmäßigkeit erfolgt prozessbegleitend und ergebnisorientiert, um mögliche technische oder didaktische Fehler vor Fertigstellung des Systems aufzudecken. Drei zeitlich versetzte Evaluationen fokussieren dabei chirurgisch-fachliche, didaktische sowie haptisch-ergonomische Akzeptanzkriterien. KW - Virtuelles Training KW - Haptisches Feedback KW - Gamification in der Medizin KW - Cochlea-Implantat KW - Operationstechnik KW - Simulation KW - Haptische Feedback-Technologie KW - Lernprogramm Y1 - 2016 UR - https://curac.org/images/advportfoliopro/images/CURAC2016/CURAC%202016%20Tagungsband.pdf SP - 21 EP - 26 ER - TY - CHAP A1 - Souza Jr., Luis Antonio de A1 - Hook, Christian A1 - Papa, João Paulo A1 - Palm, Christoph T1 - Barrett's Esophagus Analysis Using SURF Features T2 - Bildverarbeitung für die Medizin 2017; Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 12. bis 14. März 2017 in Heidelberg N2 - The development of adenocarcinoma in Barrett’s esophagus is difficult to detect by endoscopic surveillance of patients with signs of dysplasia. Computer assisted diagnosis of endoscopic images (CAD) could therefore be most helpful in the demarcation and classification of neoplastic lesions. In this study we tested the feasibility of a CAD method based on Speeded up Robust Feature Detection (SURF). A given database containing 100 images from 39 patients served as benchmark for feature based classification models. Half of the images had previously been diagnosed by five clinical experts as being ”cancerous”, the other half as ”non-cancerous”. Cancerous image regions had been visibly delineated (masked) by the clinicians. SURF features acquired from full images as well as from masked areas were utilized for the supervised training and testing of an SVM classifier. The predictive accuracy of the developed CAD system is illustrated by sensitivity and specificity values. The results based on full image matching where 0.78 (sensitivity) and 0.82 (specificity) were achieved, while the masked region approach generated results of 0.90 and 0.95, respectively. KW - Speiseröhrenkrankheit KW - Diagnose KW - Maschinelles Sehen KW - Automatische Klassifikation Y1 - 2017 U6 - https://doi.org/10.1007/978-3-662-54345-0_34 SP - 141 EP - 146 PB - Springer CY - Berlin ER - TY - CHAP A1 - Mendel, Robert A1 - Ebigbo, Alanna A1 - Probst, Andreas A1 - Messmann, Helmut A1 - Palm, Christoph T1 - Barrett’s Esophagus Analysis Using Convolutional Neural Networks T2 - Bildverarbeitung für die Medizin 2017; Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 12. bis 14. März 2017 in Heidelberg N2 - We propose an automatic approach for early detection of adenocarcinoma in the esophagus. High-definition endoscopic images (50 cancer, 50 Barrett) are partitioned into a dataset containing approximately equal amounts of patches showing cancerous and non-cancerous regions. A deep convolutional neural network is adapted to the data using a transfer learning approach. The final classification of an image is determined by at least one patch, for which the probability being a cancer patch exceeds a given threshold. The model was evaluated with leave one patient out cross-validation. With sensitivity and specificity of 0.94 and 0.88, respectively, our findings improve recently published results on the same image data base considerably. Furthermore, the visualization of the class probabilities of each individual patch indicates, that our approach might be extensible to the segmentation domain. KW - Speiseröhrenkrebs KW - Diagnose KW - Maschinelles Lernen KW - Bilderkennung KW - Automatische Klassifikation Y1 - 2017 U6 - https://doi.org/10.1007/978-3-662-54345-0_23 SP - 80 EP - 85 PB - Springer CY - Berlin ER - TY - CHAP A1 - Maier, Johannes A1 - Haug, Sonja A1 - Huber, Michaela A1 - Katzky, Uwe A1 - Neumann, Sabine A1 - Perret, Jérôme A1 - Prinzen, Martin A1 - Weber, Karsten A1 - Wittenberg, Thomas A1 - Wöhl, Rebecca A1 - Scorna, Ulrike A1 - Palm, Christoph T1 - Development of a haptic and visual assisted training simulation concept for complex bone drilling in minimally invasive hand surgery T2 - CARS Conference, 5.10.-7.10.2017 Y1 - 2017 ER - TY - JOUR A1 - Souza Jr., Luis Antonio de A1 - Passos, Leandro A. A1 - Santana, Marcos Cleison S. A1 - Mendel, Robert A1 - Rauber, David A1 - Ebigbo, Alanna A1 - Probst, Andreas A1 - Messmann, Helmut A1 - Papa, João Paulo A1 - Palm, Christoph T1 - Layer-selective deep representation to improve esophageal cancer classification JF - Medical & Biological Engineering & Computing N2 - Even though artificial intelligence and machine learning have demonstrated remarkable performances in medical image computing, their accountability and transparency level must be improved to transfer this success into clinical practice. The reliability of machine learning decisions must be explained and interpreted, especially for supporting the medical diagnosis.For this task, the deep learning techniques’ black-box nature must somehow be lightened up to clarify its promising results. Hence, we aim to investigate the impact of the ResNet-50 deep convolutional design for Barrett’s esophagus and adenocarcinoma classification. For such a task, and aiming at proposing a two-step learning technique, the output of each convolutional layer that composes the ResNet-50 architecture was trained and classified for further definition of layers that would provide more impact in the architecture. We showed that local information and high-dimensional features are essential to improve the classification for our task. Besides, we observed a significant improvement when the most discriminative layers expressed more impact in the training and classification of ResNet-50 for Barrett’s esophagus and adenocarcinoma classification, demonstrating that both human knowledge and computational processing may influence the correct learning of such a problem. KW - Multistep training KW - Barrett’s esophagus detection KW - Convolutional neural networks KW - Deep learning Y1 - 2024 U6 - https://doi.org/10.1007/s11517-024-03142-8 VL - 62 SP - 3355 EP - 3372 PB - Springer Nature CY - Heidelberg ER - TY - JOUR A1 - Ebigbo, Alanna A1 - Mendel, Robert A1 - Probst, Andreas A1 - Meinikheim, Michael A1 - Byrne, Michael F. A1 - Messmann, Helmut A1 - Palm, Christoph T1 - Multimodal imaging for detection and segmentation of Barrett’s esophagus-related neoplasia using artificial intelligence JF - Endoscopy N2 - The early diagnosis of cancer in Barrett’s esophagus is crucial for improving the prognosis. However, identifying Barrett’s esophagus-related neoplasia (BERN) is challenging, even for experts [1]. Four-quadrant biopsies may improve the detection of neoplasia, but they can be associated with sampling errors. The application of artificial intelligence (AI) to the assessment of Barrett’s esophagus could improve the diagnosis of BERN, and this has been demonstrated in both preclinical and clinical studies [2] [3]. In this video demonstration, we show the accurate detection and delineation of BERN in two patients ([Video 1]). In part 1, the AI system detects a mucosal cancer about 20 mm in size and accurately delineates the lesion in both white-light and narrow-band imaging. In part 2, a small island of BERN with high-grade dysplasia is detected and delineated in white-light, narrow-band, and texture and color enhancement imaging. The video shows the results using a transparent overlay of the mucosal cancer in real time as well as a full segmentation preview. Additionally, the optical flow allows for the assessment of endoscope movement, something which is inversely related to the reliability of the AI prediction. We demonstrate that multimodal imaging can be applied to the AI-assisted detection and segmentation of even small focal lesions in real time. KW - Video KW - Artificial Intelligence KW - Multimodal Imaging Y1 - 2022 U6 - https://doi.org/10.1055/a-1704-7885 VL - 54 IS - 10 PB - Georg Thieme Verlag CY - Stuttgart ET - E-Video ER - TY - JOUR A1 - Kolev, Kalin A1 - Kirchgeßner, Norbert A1 - Houben, Sebastian A1 - Csiszár, Agnes A1 - Rubner, Wolfgang A1 - Palm, Christoph A1 - Eiben, Björn A1 - Merkel, Rudolf A1 - Cremers, Daniel T1 - A variational approach to vesicle membrane reconstruction from fluorescence imaging JF - Pattern Recognition N2 - Biological applications like vesicle membrane analysis involve the precise segmentation of 3D structures in noisy volumetric data, obtained by techniques like magnetic resonance imaging (MRI) or laser scanning microscopy (LSM). Dealing with such data is a challenging task and requires robust and accurate segmentation methods. In this article, we propose a novel energy model for 3D segmentation fusing various cues like regional intensity subdivision, edge alignment and orientation information. The uniqueness of the approach consists in the definition of a new anisotropic regularizer, which accounts for the unbalanced slicing of the measured volume data, and the generalization of an efficient numerical scheme for solving the arising minimization problem, based on linearization and fixed-point iteration. We show how the proposed energy model can be optimized globally by making use of recent continuous convex relaxation techniques. The accuracy and robustness of the presented approach are demonstrated by evaluating it on multiple real data sets and comparing it to alternative segmentation methods based on level sets. Although the proposed model is designed with focus on the particular application at hand, it is general enough to be applied to a variety of different segmentation tasks. KW - 3D segmentation KW - Convex optimization KW - Vesicle membrane analysis KW - Fluorescence imaging KW - Dreidimensionale Bildverarbeitung KW - Bildsegmentierung KW - Konvexe Optimierung Y1 - 2011 U6 - https://doi.org/10.1016/j.patcog.2011.04.019 VL - 44 IS - 12 SP - 2944 EP - 2958 PB - Elsevier ER - TY - CHAP A1 - Metzler, V. A1 - Aach, T. A1 - Palm, Christoph A1 - Lehmann, Thomas M. T1 - Texture Classification of Graylevel Images by Multiscale Cross-Co-Occurrence Matrices T2 - Proceedings 15th International Conference on Pattern Recognition (ICPR-2000) N2 - Local gray level dependencies of natural images can be modelled by means of co-occurrence matrices containing joint probabilities of gray-level pairs. Texture, however, is a resolution-dependent phenomenon and hence, classification depends on the chosen scale. Since there is no optimal scale for all textures we employ a multiscale approach that acquires textural features at several scales. Thus linear and nonlinear scale-spaces are analyzed by multiscale co-occurrence matrices that describe the statistical behavior of a texture in scale-space. Classification is then performed on the basis of texture features taken from the individual scale with the highest discriminatory power. By considering cross-scale occurrences of gray level pairs, the impact of filters on the feature is described and used for classification of natural textures. This novel method was found to improve classification rates of the common co-occurrence matrix approach on standard textures significantly. Y1 - 2000 U6 - https://doi.org/10.1109/ICPR.2000.906133 SP - 549 EP - 552 ER - TY - GEN A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Probst, Andreas A1 - Scheppach, Markus W. A1 - Messmann, Helmut A1 - Palm, Christoph A1 - Ebigbo, Alanna T1 - Optical Flow als Methode zur Qualitätssicherung KI-unterstützter Untersuchungen von Barrett-Ösophagus und Barrett-Ösophagus assoziierten Neoplasien T2 - Zeitschrift für Gastroenterologie N2 - Einleitung  Übermäßige Bewegung im Bild kann die Performance von auf künstlicher Intelligenz (KI) basierenden klinischen Entscheidungsunterstützungssystemen (CDSS) reduzieren. Optical Flow (OF) ist eine Methode zur Lokalisierung und Quantifizierung von Bewegungen zwischen aufeinanderfolgenden Bildern. Ziel  Ziel ist es, die Mensch-Computer-Interaktion (HCI) zu verbessern und Endoskopiker die unser KI-System „Barrett-Ampel“ zur Unterstützung bei der Beurteilung von Barrett-Ösophagus (BE) verwenden, ein Echtzeit-Feedback zur aktuellen Datenqualität anzubieten. Methodik  Dazu wurden unveränderte Videos in „Weißlicht“ (WL), „Narrow Band Imaging“ (NBI) und „Texture and Color Enhancement Imaging“ (TXI) von acht endoskopischen Untersuchungen von histologisch gesichertem BE und mit Barrett-Ösophagus assoziierten Neoplasien (BERN) durch unseren KI-Algorithmus analysiert. Der zur Bewertung der Bildqualität verwendete OF beinhaltete die mittlere Magnitude und die Entropie des Histogramms der Winkel. Frames wurden automatisch extrahiert, wenn die vordefinierten Schwellenwerte von 3,0 für die mittlere Magnitude und 9,0 für die Entropie des Histogramms der Winkel überschritten wurden. Experten sahen sich zunächst die Videos ohne KI-Unterstützung an und bewerteten, ob Störfaktoren die Sicherheit mit der eine Diagnose im vorliegenden Fall gestellt werden kann negativ beeinflussen. Anschließend überprüften sie die extrahierten Frames. Ergebnis  Gleichmäßige Bewegung in eine Richtung, wie etwa beim Vorschieben des Endoskops, spiegelte sich, bei insignifikant veränderter Entropie, in einer Erhöhung der Magnitude wider. Chaotische Bewegung, zum Beispiel während dem Spülen, war mit erhöhter Entropie assoziiert. Insgesamt war eine unruhige endoskopische Darstellung, Flüssigkeit sowie übermäßige Ösophagusmotilität mit erhöhtem OF assoziiert und korrelierte mit der Meinung der Experten über die Qualität der Videos. Der OF und die subjektive Wahrnehmung der Experten über die Verwertbarkeit der vorliegenden Bildsequenzen korrelierten direkt proportional. Wenn die vordefinierten Schwellenwerte des OF überschritten wurden, war die damit verbundene Bildqualität in 94% der Fälle für eine definitive Interpretation auch für Experten unzureichend. Schlussfolgerung  OF hat das Potenzial Endoskopiker ein Echtzeit-Feedback über die Qualität des Dateninputs zu bieten und so nicht nur die HCI zu verbessern, sondern auch die optimale Performance von KI-Algorithmen zu ermöglichen. KW - Optical Flow Y1 - 2022 U6 - https://doi.org/10.1055/s-0042-1754997 VL - 60 IS - 08 PB - Georg Thieme Verlag CY - Stuttgart ER - TY - GEN A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Scheppach, Markus W. A1 - Probst, Andreas A1 - Prinz, Friederike A1 - Schwamberger, Tanja A1 - Schlottmann, Jakob A1 - Gölder, Stefan Karl A1 - Walter, Benjamin A1 - Steinbrück, Ingo A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Einsatz von künstlicher Intelligenz (KI) als Entscheidungsunterstützungssystem für nicht-Experten bei der Beurteilung von Barrett-Ösophagus assoziierten Neoplasien (BERN) T2 - Zeitschrift für Gastroenterologie N2 - Einleitung Die sichere Detektion und Charakterisierung von Barrett-Ösophagus assoziierten Neoplasien (BERN) stellt selbst für erfahrene Endoskopiker eine Herausforderung dar. Ziel Ziel dieser Studie ist es, den Add-on Effekt eines künstlichen Intelligenz (KI) Systems (Barrett-Ampel) als Entscheidungsunterstüzungssystem für Endoskopiker ohne Expertise bei der Untersuchung von BERN zu evaluieren. Material und Methodik Zwölf Videos in „Weißlicht“ (WL), „narrow-band imaging“ (NBI) und „texture and color enhanced imaging“ (TXI) von histologisch bestätigten Barrett-Metaplasien oder BERN wurden von Experten und Untersuchern ohne Barrett-Expertise evaluiert. Die Probanden wurden dazu aufgefordert in den Videos auftauchende BERN zu identifizieren und gegebenenfalls die optimale Biopsiestelle zu markieren. Unser KI-System wurde demselben Test unterzogen, wobei dieses BERN in Echtzeit segmentierte und farblich von umliegendem Epithel differenzierte. Anschließend wurden den Probanden die Videos mit zusätzlicher KI-Unterstützung gezeigt. Basierend auf dieser neuen Information, wurden die Probanden zu einer Reevaluation ihrer initialen Beurteilung aufgefordert. Ergebnisse Die „Barrett-Ampel“ identifizierte unabhängig von den verwendeten Darstellungsmodi (WL, NBI, TXI) alle BERN. Zwei entzündlich veränderte Läsionen wurden fehlinterpretiert (Genauigkeit=75%). Während Experten vergleichbare Ergebnisse erzielten (Genauigkeit=70,8%), hatten Endoskopiker ohne Expertise bei der Beurteilung von Barrett-Metaplasien eine Genauigkeit von lediglich 58,3%. Wurden die nicht-Experten allerdings von unserem KI-System unterstützt, erreichten diese eine Genauigkeit von 75%. Zusammenfassung Unser KI-System hat das Potential als Entscheidungsunterstützungssystem bei der Differenzierung zwischen Barrett-Metaplasie und BERN zu fungieren und so Endoskopiker ohne entsprechende Expertise zu assistieren. Eine Limitation dieser Studie ist die niedrige Anzahl an eingeschlossenen Videos. Um die Ergebnisse dieser Studie zu bestätigen, müssen randomisierte kontrollierte klinische Studien durchgeführt werden. KW - Barrett-Ösophagus KW - Künstliche Intelligenz Y1 - 2022 U6 - https://doi.org/10.1055/s-0042-1745653 VL - 60 IS - 4 SP - 251 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Scheppach, Markus W. A1 - Probst, Andreas A1 - Prinz, Friederike A1 - Schwamberger, Tanja A1 - Schlottmann, Jakob A1 - Gölder, Stefan Karl A1 - Walter, Benjamin A1 - Steinbrück, Ingo A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - INFLUENCE OF AN ARTIFICIAL INTELLIGENCE (AI) BASED DECISION SUPPORT SYSTEM (DSS) ON THE DIAGNOSTIC PERFORMANCE OF NON-EXPERTS IN BARRETT´S ESOPHAGUS RELATED NEOPLASIA (BERN) T2 - Endoscopy N2 - Aims Barrett´s esophagus related neoplasia (BERN) is difficult to detect and characterize during endoscopy, even for expert endoscopists. We aimed to assess the add-on effect of an Artificial Intelligence (AI) algorithm (Barrett-Ampel) as a decision support system (DSS) for non-expert endoscopists in the evaluation of Barrett’s esophagus (BE) and BERN. Methods Twelve videos with multimodal imaging white light (WL), narrow-band imaging (NBI), texture and color enhanced imaging (TXI) of histologically confirmed BE and BERN were assessed by expert and non-expert endoscopists. For each video, endoscopists were asked to identify the area of BERN and decide on the biopsy spot. Videos were assessed by the AI algorithm and regions of BERN were highlighted in real-time by a transparent overlay. Finally, endoscopists were shown the AI videos and asked to either confirm or change their initial decision based on the AI support. Results Barrett-Ampel correctly identified all areas of BERN, irrespective of the imaging modality (WL, NBI, TXI), but misinterpreted two inflammatory lesions (Accuracy=75%). Expert endoscopists had a similar performance (Accuracy=70,8%), while non-experts had an accuracy of 58.3%. When AI was implemented as a DSS, non-expert endoscopists improved their diagnostic accuracy to 75%. Conclusions AI may have the potential to support non-expert endoscopists in the assessment of videos of BE and BERN. Limitations of this study include the low number of videos used. Randomized clinical trials in a real-life setting should be performed to confirm these results. KW - Artificial Intelligence KW - Barrett's Esophagus KW - Speiseröhrenkrankheit KW - Künstliche Intelligenz KW - Diagnose Y1 - 2022 U6 - https://doi.org/10.1055/s-00000012 VL - 54 IS - S 01 SP - S39 PB - Thieme ER - TY - JOUR A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Probst, Andreas A1 - Meinikheim, Michael A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - ARTIFICIAL INTELLIGENCE (AI) – ASSISTED VESSEL AND TISSUE RECOGNITION IN THIRD-SPACE ENDOSCOPY JF - Endoscopy N2 - Aims Third-space endoscopy procedures such as endoscopic submucosal dissection (ESD) and peroral endoscopic myotomy (POEM) are complex interventions with elevated risk of operator-dependent adverse events, such as intra-procedural bleeding and perforation. We aimed to design an artificial intelligence clinical decision support solution (AI-CDSS, “Smart ESD”) for the detection and delineation of vessels, tissue structures, and instruments during third-space endoscopy procedures. Methods Twelve full-length third-space endoscopy videos were extracted from the Augsburg University Hospital database. 1686 frames were annotated for the following categories: Submucosal layer, blood vessels, electrosurgical knife and endoscopic instrument. A DeepLabv3+neural network with a 101-layer ResNet backbone was trained and validated internally. Finally, the ability of the AI system to detect visible vessels during ESD and POEM was determined on 24 separate video clips of 7 to 46 seconds duration and showing 33 predefined vessels. These video clips were also assessed by an expert in third-space endoscopy. Results Smart ESD showed a vessel detection rate (VDR) of 93.94%, while an average of 1.87 false positive signals were recorded per minute. VDR of the expert endoscopist was 90.1% with no false positive findings. On the internal validation data set using still images, the AI system demonstrated an Intersection over Union (IoU), mean Dice score and pixel accuracy of 63.47%, 76.18% and 86.61%, respectively. Conclusions This is the first AI-CDSS aiming to mitigate operator-dependent limitations during third-space endoscopy. Further clinical trials are underway to better understand the role of AI in such procedures. KW - Artificial Intelligence KW - Third-Space Endoscopy KW - Smart ESD Y1 - 2022 U6 - https://doi.org/10.1055/s-0042-1745037 VL - 54 IS - S01 SP - S175 PB - Thieme ER - TY - CHAP A1 - Weber Nunes, Danilo A1 - Rauber, David A1 - Palm, Christoph ED - Palm, Christoph ED - Breininger, Katharina ED - Deserno, Thomas M. ED - Handels, Heinz ED - Maier, Andreas ED - Maier-Hein, Klaus H. ED - Tolxdorff, Thomas T1 - Self-supervised 3D Vision Transformer Pre-training for Robust Brain Tumor Classification T2 - Bildverarbeitung für die Medizin 2025: Proceedings, German Conference on Medical Image Computing, Regensburg March 09-11, 2025 N2 - Brain tumors pose significant challenges in neurology, making precise classification crucial for prognosis and treatment planning. This work investigates the effectiveness of a self-supervised learning approach–masked autoencoding (MAE)–to pre-train a vision transformer (ViT) model for brain tumor classification. Our method uses non-domain specific data, leveraging the ADNI and OASIS-3 MRI datasets, which primarily focus on degenerative diseases, for pretraining. The model is subsequently fine-tuned and evaluated on the BraTS glioma and meningioma datasets, representing a novel use of these datasets for tumor classification. The pre-trained MAE ViT model achieves an average F1 score of 0.91 in a 5-fold cross-validation setting, outperforming the nnU-Net encoder trained from scratch, particularly under limited data conditions. These findings highlight the potential of self-supervised MAE in enhancing brain tumor classification accuracy, even with restricted labeled data. Y1 - 2025 U6 - https://doi.org/10.1007/978-3-658-47422-5_69 SP - 298 EP - 303 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Weiherer, Maximilian A1 - von Riedheim, Antonia A1 - Brébant, Vanessa A1 - Egger, Bernhard A1 - Palm, Christoph ED - Palm, Christoph ED - Breininger, Katharina ED - Deserno, Thomas M. ED - Handels, Heinz ED - Maier, Andreas ED - Maier-Hein, Klaus H. ED - Tolxdorff, Thomas T1 - iRBSM: A Deep Implicit 3D Breast Shape Model T2 - Bildverarbeitung für die Medizin 2025: Proceedings, German Conference on Medical Image Computing, Regensburg March 09-11, 2025 N2 - We present the first deep implicit 3D shape model of the female breast, building upon and improving the recently proposed Regensburg Breast Shape Model (RBSM). Compared to its PCA-based predecessor, our model employs implicit neural representations; hence, it can be trained on raw 3D breast scans and eliminates the need for computationally demanding non-rigid registration, a task that is particularly difficult for feature-less breast shapes. The resulting model, dubbed iRBSM, captures detailed surface geometry including fine structures such as nipples and belly buttons, is highly expressive, and outperforms the RBSM on different surface reconstruction tasks. Finally, leveraging the iRBSM, we present a prototype application to 3D reconstruct breast shapes from just a single image. Model and code publicly available at https://rbsm.re-mic.de/implicit. Y1 - 2025 U6 - https://doi.org/10.1007/978-3-658-47422-5_11 SP - 38 EP - 43 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Gutbrod, Max A1 - Geisler, Benedikt A1 - Rauber, David A1 - Palm, Christoph ED - Maier, Andreas ED - Deserno, Thomas M. ED - Handels, Heinz ED - Maier-Hein, Klaus H. ED - Palm, Christoph ED - Tolxdorff, Thomas T1 - Data Augmentation for Images of Chronic Foot Wounds T2 - Bildverarbeitung für die Medizin 2024: Proceedings, German Workshop on Medical Image Computing, March 10-12, 2024, Erlangen N2 - Training data for Neural Networks is often scarce in the medical domain, which often results in models that struggle to generalize and consequently showpoor performance on unseen datasets. Generally, adding augmentation methods to the training pipeline considerably enhances a model’s performance. Using the dataset of the Foot Ulcer Segmentation Challenge, we analyze two additional augmentation methods in the domain of chronic foot wounds - local warping of wound edges along with projection and blurring of shapes inside wounds. Our experiments show that improvements in the Dice similarity coefficient and Normalized Surface Distance metrics depend on a sensible selection of those augmentation methods. Y1 - 2024 U6 - https://doi.org/10.1007/978-3-658-44037-4_71 SP - 261 EP - 266 PB - Springer CY - Wiesbaden ER - TY - GEN A1 - Schroeder, Josef A. A1 - Semmelmann, Matthias A1 - Siegmund, Heiko A1 - Grafe, Claudia A1 - Evert, Matthias A1 - Palm, Christoph T1 - Improved interactive computer-assisted approach for evaluation of ultrastructural cilia abnormalities T2 - Ultrastructural Pathology KW - Zilie KW - Ultrastruktur KW - Anomalie KW - Bildverarbeitung KW - Computerunterstütztes Verfahren Y1 - 2017 U6 - https://doi.org/10.1080/01913123.2016.1270978 VL - 41 IS - 1 SP - 112 EP - 113 ER - TY - CHAP A1 - Rückert, Tobias A1 - Rieder, Maximilian A1 - Feussner, Hubertus A1 - Wilhelm, Dirk A1 - Rückert, Daniel A1 - Palm, Christoph ED - Maier, Andreas ED - Deserno, Thomas M. ED - Handels, Heinz ED - Maier-Hein, Klaus H. ED - Palm, Christoph ED - Tolxdorff, Thomas T1 - Smoke Classification in Laparoscopic Cholecystectomy Videos Incorporating Spatio-temporal Information T2 - Bildverarbeitung für die Medizin 2024: Proceedings, German Workshop on Medical Image Computing, March 10-12, 2024, Erlangen N2 - Heavy smoke development represents an important challenge for operating physicians during laparoscopic procedures and can potentially affect the success of an intervention due to reduced visibility and orientation. Reliable and accurate recognition of smoke is therefore a prerequisite for the use of downstream systems such as automated smoke evacuation systems. Current approaches distinguish between non-smoked and smoked frames but often ignore the temporal context inherent in endoscopic video data. In this work, we therefore present a method that utilizes the pixel-wise displacement from randomly sampled images to the preceding frames determined using the optical flow algorithm by providing the transformed magnitude of the displacement as an additional input to the network. Further, we incorporate the temporal context at evaluation time by applying an exponential moving average on the estimated class probabilities of the model output to obtain more stable and robust results over time. We evaluate our method on two convolutional-based and one state-of-the-art transformer architecture and show improvements in the classification results over a baseline approach, regardless of the network used. Y1 - 2024 U6 - https://doi.org/10.1007/978-3-658-44037-4_78 SP - 298 EP - 303 PB - Springeer CY - Wiesbaden ER - TY - INPR A1 - Mendel, Robert A1 - Rückert, Tobias A1 - Wilhelm, Dirk A1 - Rückert, Daniel A1 - Palm, Christoph T1 - Motion-Corrected Moving Average: Including Post-Hoc Temporal Information for Improved Video Segmentation N2 - Real-time computational speed and a high degree of precision are requirements for computer-assisted interventions. Applying a segmentation network to a medical video processing task can introduce significant inter-frame prediction noise. Existing approaches can reduce inconsistencies by including temporal information but often impose requirements on the architecture or dataset. This paper proposes a method to include temporal information in any segmentation model and, thus, a technique to improve video segmentation performance without alterations during training or additional labeling. With Motion-Corrected Moving Average, we refine the exponential moving average between the current and previous predictions. Using optical flow to estimate the movement between consecutive frames, we can shift the prior term in the moving-average calculation to align with the geometry of the current frame. The optical flow calculation does not require the output of the model and can therefore be performed in parallel, leading to no significant runtime penalty for our approach. We evaluate our approach on two publicly available segmentation datasets and two proprietary endoscopic datasets and show improvements over a baseline approach. KW - Deep Learning KW - Video KW - Segmentation Y1 - 2024 U6 - https://doi.org/10.48550/arXiv.2403.03120 ER - TY - GEN A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Probst, Andreas A1 - Meinikheim, Michael A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Artificial Intelligence (AI) – assisted vessel and tissue recognition during third space endoscopy (Smart ESD) T2 - Zeitschrift für Gastroenterologie N2 - Clinical setting  Third space procedures such as endoscopic submucosal dissection (ESD) and peroral endoscopic myotomy (POEM) are complex minimally invasive techniques with an elevated risk for operator-dependent adverse events such as bleeding and perforation. This risk arises from accidental dissection into the muscle layer or through submucosal blood vessels as the submucosal cutting plane within the expanding resection site is not always apparent. Deep learning algorithms have shown considerable potential for the detection and characterization of gastrointestinal lesions. So-called AI – clinical decision support solutions (AI-CDSS) are commercially available for polyp detection during colonoscopy. Until now, these computer programs have concentrated on diagnostics whereas an AI-CDSS for interventional endoscopy has not yet been introduced. We aimed to develop an AI-CDSS („Smart ESD“) for real-time intra-procedural detection and delineation of blood vessels, tissue structures and endoscopic instruments during third-space endoscopic procedures. Characteristics of Smart ESD  An AI-CDSS was invented that delineates blood vessels, tissue structures and endoscopic instruments during third-space endoscopy in real-time. The output can be displayed by an overlay over the endoscopic image with different modes of visualization, such as a color-coded semitransparent area overlay, or border tracing (demonstration video). Hereby the optimal layer for dissection can be visualized, which is close above or directly at the muscle layer, depending on the applied technique (ESD or POEM). Furthermore, relevant blood vessels (thickness> 1mm) are delineated. Spatial proximity between the electrosurgical knife and a blood vessel triggers a warning signal. By this guidance system, inadvertent dissection through blood vessels could be averted. Technical specifications  A DeepLabv3+ neural network architecture with KSAC and a 101-layer ResNeSt backbone was used for the development of Smart ESD. It was trained and validated with 2565 annotated still images from 27 full length third-space endoscopic videos. The annotation classes were blood vessel, submucosal layer, muscle layer, electrosurgical knife and endoscopic instrument shaft. A test on a separate data set yielded an intersection over union (IoU) of 68%, a Dice Score of 80% and a pixel accuracy of 87%, demonstrating a high overlap between expert and AI segmentation. Further experiments on standardized video clips showed a mean vessel detection rate (VDR) of 85% with values of 92%, 70% and 95% for POEM, rectal ESD and esophageal ESD respectively. False positive measurements occurred 0.75 times per minute. 7 out of 9 vessels which caused intraprocedural bleeding were caught by the algorithm, as well as both vessels which required hemostasis via hemostatic forceps. Future perspectives  Smart ESD performed well for vessel and tissue detection and delineation on still images, as well as on video clips. During a live demonstration in the endoscopy suite, clinical applicability of the innovation was examined. The lag time for processing of the live endoscopic image was too short to be visually detectable for the interventionist. Even though the algorithm could not be applied during actual dissection by the interventionist, Smart ESD appeared readily deployable during visual assessment by ESD experts. Therefore, we plan to conduct a clinical trial in order to obtain CE-certification of the algorithm. This new technology may improve procedural safety and speed, as well as training of modern minimally invasive endoscopic resection techniques. KW - Artificial Intelligence KW - Medical Image Computing KW - Endoscopy KW - Bildgebendes Verfahren KW - Medizin KW - Künstliche Intelligenz KW - Endoskopie Y1 - 2022 U6 - https://doi.org/10.1055/s-0042-1755110 VL - 60 IS - 08 PB - Georg Thieme Verlag CY - Stuttgart ER - TY - GEN A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Probst, Andreas A1 - Scheppach, Markus W. A1 - Messmann, Helmut A1 - Palm, Christoph A1 - Ebigbo, Alanna T1 - Barrett-Ampel T2 - Zeitschrift für Gastroenterologie N2 - Hintergrund  Adenokarzinome des Ösophagus sind bis heute mit einer infausten Prognose vergesellschaftet (1). Obwohl Endoskopiker mit Barrett-Ösophagus als Präkanzerose konfrontiert werden, ist vor allem für nicht-Experten die Differenzierung zwischen Barrett-Ösophagus ohne Dysplasie und assoziierten Neoplasien mitunter schwierig. Existierende Biopsieprotokolle (z.B. Seattle Protokoll) sind oftmals unzuverlässig (2). Eine frühzeitige Diagnose des Adenokarzinoms ist allerdings von fundamentaler Bedeutung für die Prognose des Patienten. Forschungsansatz  Auf der Grundlage dieser Problematik, entwickelten wir in Kooperation mit dem Forschungslabor „Regensburg Medical Image Computing (ReMIC)“ der OTH Regensburg ein auf künstlicher Intelligenz (KI) basiertes Entscheidungsunterstützungssystem (CDSS). Das auf einer DeepLabv3+ neuronalen Netzwerkarchitektur basierende CDSS differenziert mittels Mustererkennung Barrett- Ösophagus ohne Dysplasie von Barrett-Ösophagus mit Dysplasie bzw. Neoplasie („Klassifizierung“). Hierbei werden gemittelte Ausgabewahrscheinlichkeiten mit einem vom Benutzer definierten Schwellenwert verglichen. Für Vorhersagen, die den Schwellenwert überschreiten, berechnen wir die Kontur der Region und die Fläche. Sobald die vorhergesagte Läsion eine bestimmte Größe in der Eingabe überschreitet, heben wir sie und ihren Umriss hervor. So ermöglicht eine farbkodierte Visualisierung eine Abgrenzung zwischen Dysplasie bzw. Neoplasie und normalem Barrett-Epithel („Segmentierung“). In einer Studie an Bildern in „Weißlicht“ (WL) und „Narrow Band Imaging“ (NBI) demonstrierten wir eine Sensitivität von mehr als 90% und eine Spezifität von mehr als 80% (3). In einem nächsten Schritt, differenzierte unser KI-Algorithmus Barrett- Metaplasien von assoziierten Neoplasien anhand von zufällig abgegriffenen Bildern in Echtzeit mit einer Accuracy von 89.9% (4). Darauf folgend, entwickelten wir unser System dahingehend weiter, dass unser Algorithmus nun auch dazu in der Lage ist, Untersuchungsvideos in WL, NBI und „Texture and Color Enhancement Imaging“ (TXI) in Echtzeit zu analysieren (5). Aktuell führen wir eine Studie in einem randomisiert-kontrollierten Ansatz an unveränderten Untersuchungsvideos in WL, NBI und TXI durch. Ausblick  Um Patienten mit aus Barrett-Metaplasien resultierenden Neoplasien frühestmöglich an „High-Volume“-Zentren überweisen zu können, soll unser KI-Algorithmus zukünftig vor allem Endoskopiker ohne extensive Erfahrung bei der Beurteilung von Barrett- Ösophagus in der Krebsfrüherkennung unterstützen. KW - Barrett-Ösophagus KW - Adenokarzinom KW - Künstliche Intelligenz KW - Speiseröhrenkrebs KW - Diagnose KW - Künstliche Intelligenz Y1 - 2022 U6 - https://doi.org/10.1055/s-0042-1755109 VL - 60 IS - 08 PB - Georg Thieme Verlag CY - Stuttgart ER - TY - GEN A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Probst, Andreas A1 - Meinikheim, Michael A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Intraprozedurale Strukturerkennung bei Third-Space Endoskopie mithilfe eines Deep-Learning Algorithmus T2 - Zeitschrift für Gastroenterologie N2 - Einleitung Third-Space Interventionen wie die endoskopische Submukosadissektion (ESD) und die perorale endoskopische Myotomie (POEM) sind technisch anspruchsvoll und mit einem erhöhten Risiko für intraprozedurale Komplikationen wie Blutung oder Perforation assoziiert. Moderne Computerprogramme zur Unterstützung bei diagnostischen Entscheidungen werden unter Einsatz von künstlicher Intelligenz (KI) in der Endoskopie bereits erfolgreich eingesetzt. Ziel der vorliegenden Arbeit war es, relevante anatomische Strukturen mithilfe eines Deep-Learning Algorithmus zu detektieren und segmentieren, um die Sicherheit und Anwendbarkeit von ESD und POEM zu erhöhen. Methoden Zwölf Videoaufnahmen in voller Länge von Third-Space Endoskopien wurden aus der Datenbank des Universitätsklinikums Augsburg extrahiert. 1686 Einzelbilder wurden für die Kategorien Submukosa, Blutgefäß, Dissektionsmesser und endoskopisches Instrument annotiert und segmentiert. Mit diesem Datensatz wurde ein DeepLabv3+neuronales Netzwerk auf der Basis eines ResNet mit 101 Schichten trainiert und intern anhand der Parameter Intersection over Union (IoU), Dice Score und Pixel Accuracy validiert. Die Fähigkeit des Algorithmus zur Gefäßdetektion wurde anhand von 24 Videoclips mit einer Spieldauer von 7 bis 46 Sekunden mit 33 vordefinierten Gefäßen evaluiert. Anhand dieses Tests wurde auch die Gefäßdetektionsrate eines Experten in der Third-Space Endoskopie ermittelt. Ergebnisse Der Algorithmus zeigte eine Gefäßdetektionsrate von 93,94% mit einer mittleren Rate an falsch positiven Signalen von 1,87 pro Minute. Die Gefäßdetektionsrate des Experten lag bei 90,1% ohne falsch positive Ergebnisse. In der internen Validierung an Einzelbildern wurde eine IoU von 63,47%, ein mittlerer Dice Score von 76,18% und eine Pixel Accuracy von 86,61% ermittelt. Zusammenfassung Dies ist der erste KI-Algorithmus, der für den Einsatz in der therapeutischen Endoskopie entwickelt wurde. Präliminäre Ergebnisse deuten auf eine mit Experten vergleichbare Detektion von Gefäßen während der Untersuchung hin. Weitere Untersuchungen sind nötig, um die Leistung des Algorithmus im Vergleich zum Experten genauer zu eruieren sowie einen möglichen klinischen Nutzen zu ermitteln. KW - Deep Learning KW - Third-Space Endoscopy Y1 - 2022 U6 - https://doi.org/10.1055/s-0042-1745652 VL - 60 IS - 04 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Souza Jr., Luis Antonio de A1 - Pacheco, André G.C. A1 - Passos, Leandro A. A1 - Santana, Marcos Cleison S. A1 - Mendel, Robert A1 - Ebigbo, Alanna A1 - Probst, Andreas A1 - Messmann, Helmut A1 - Palm, Christoph A1 - Papa, João Paulo T1 - DeepCraftFuse: visual and deeply-learnable features work better together for esophageal cancer detection in patients with Barrett’s esophagus JF - Neural Computing and Applications N2 - Limitations in computer-assisted diagnosis include lack of labeled data and inability to model the relation between what experts see and what computers learn. Even though artificial intelligence and machine learning have demonstrated remarkable performances in medical image computing, their accountability and transparency level must be improved to transfer this success into clinical practice. The reliability of machine learning decisions must be explained and interpreted, especially for supporting the medical diagnosis. While deep learning techniques are broad so that unseen information might help learn patterns of interest, human insights to describe objects of interest help in decision-making. This paper proposes a novel approach, DeepCraftFuse, to address the challenge of combining information provided by deep networks with visual-based features to significantly enhance the correct identification of cancerous tissues in patients affected with Barrett’s esophagus (BE). We demonstrate that DeepCraftFuse outperforms state-of-the-art techniques on private and public datasets, reaching results of around 95% when distinguishing patients affected by BE that is either positive or negative to esophageal cancer. KW - Deep Learning KW - Speiseröhrenkrebs KW - Adenocarcinom KW - Endobrachyösophagus KW - Diagnose KW - Maschinelles Lernen KW - Machine learning KW - Adenocarcinoma KW - Object detector KW - Barrett’s esophagus KW - Deep Learning Y1 - 2024 U6 - https://doi.org/10.1007/s00521-024-09615-z VL - 36 SP - 10445 EP - 10459 PB - Springer CY - London ER - TY - JOUR A1 - Souza, Luis A. A1 - Pacheco, André G.C. A1 - de Souza, Alberto F. A1 - Oliveira-Santos, Thiago A1 - Badue, Claudine A1 - Palm, Christoph A1 - Papa, João Paulo T1 - TransConv: a lightweight architecture based on transformers and convolutional neural networks for adenocarcinoma and Barrett’s esophagus identification JF - Neural Computing and Applications N2 - Barrett’s esophagus, also known as BE, is commonly associated with repeated exposure to stomach acid. If not treated properly, it may evolve into esophageal adenocarcinoma, aka esophageal cancer. This paper proposes TransConv, a hybrid architecture that benefits from features learned by pre-trained vision transformers (ViTs) and convolutional neural networks (CNNs), followed by a shallow neural network composed of three normalizations, ReLU activations, and fully connected layers, and a SoftMax head to distinguish between BE and esophageal cancer. TransConv is designed to be training-lightweight, and for the ViT and CNN backbone models, weights are kept frozen during training, i.e., the primary goal of TransConv is to learn the weights of the fully connected layer from both backbones only, avoiding the burden of updating their weights but still learning their final descriptions for the lightweight convolutional model. We report promising results with low computational training costs in two datasets, one public and another private. From our achievements, TransConv was able to deliver balanced accuracy results around 85% and 86% for each evaluated dataset, respectively, in a design that required only 50 epochs of model training, a very reduced number compared to state-of-the-art conducted studies in the same domain. Y1 - 2025 U6 - https://doi.org/10.1007/s00521-025-11299-y IS - 37 SP - 15535 EP - 15546 PB - Springer ER - TY - INPR A1 - Rückert, Tobias A1 - Rückert, Daniel A1 - Palm, Christoph T1 - Methods and datasets for segmentation of minimally invasive surgical instruments in endoscopic images and videos: A review of the state of the art N2 - In the field of computer- and robot-assisted minimally invasive surgery, enormous progress has been made in recent years based on the recognition of surgical instruments in endoscopic images. Especially the determination of the position and type of the instruments is of great interest here. Current work involves both spatial and temporal information with the idea, that the prediction of movement of surgical tools over time may improve the quality of final segmentations. The provision of publicly available datasets has recently encouraged the development of new methods, mainly based on deep learning. In this review, we identify datasets used for method development and evaluation, as well as quantify their frequency of use in the literature. We further present an overview of the current state of research regarding the segmentation and tracking of minimally invasive surgical instruments in endoscopic images. The paper focuses on methods that work purely visually without attached markers of any kind on the instruments, taking into account both single-frame segmentation approaches as well as those involving temporal information. A discussion of the reviewed literature is provided, highlighting existing shortcomings and emphasizing available potential for future developments. The publications considered were identified through the platforms Google Scholar, Web of Science, and PubMed. The search terms used were "instrument segmentation", "instrument tracking", "surgical tool segmentation", and "surgical tool tracking" and result in 408 articles published between 2015 and 2022 from which 109 were included using systematic selection criteria. Y1 - 2023 U6 - https://doi.org/10.48550/arXiv.2304.13014 ER - TY - CHAP A1 - Gutbrod, Max A1 - Rauber, David A1 - Weber Nunes, Danilo A1 - Palm, Christoph T1 - OpenMIBOOD: Open Medical Imaging Benchmarks for Out-Of-Distribution Detection T2 - 2025 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), 10.-17. June 2025, Nashville N2 - The growing reliance on Artificial Intelligence (AI) in critical domains such as healthcare demands robust mechanisms to ensure the trustworthiness of these systems, especially when faced with unexpected or anomalous inputs. This paper introduces the Open Medical Imaging Benchmarks for Out-Of-Distribution Detection (OpenMIBOOD), a comprehensive framework for evaluating out-of-distribution (OOD) detection methods specifically in medical imaging contexts. OpenMIBOOD includes three benchmarks from diverse medical domains, encompassing 14 datasets divided into covariate-shifted in-distribution, nearOOD, and far-OOD categories. We evaluate 24 post-hoc methods across these benchmarks, providing a standardized reference to advance the development and fair comparison of OODdetection methods. Results reveal that findings from broad-scale OOD benchmarks in natural image domains do not translate to medical applications, underscoring the critical need for such benchmarks in the medical field. By mitigating the risk of exposing AI models to inputs outside their training distribution, OpenMIBOOD aims to support the advancement of reliable and trustworthy AI systems in healthcare. The repository is available at https://github.com/remic-othr/OpenMIBOOD. KW - Benchmark testing KW - Reliability KW - Trustworthiness KW - out-of-distribution Y1 - 2025 UR - https://openaccess.thecvf.com/content/CVPR2025/html/Gutbrod_OpenMIBOOD_Open_Medical_Imaging_Benchmarks_for_Out-Of-Distribution_Detection_CVPR_2025_paper.html SN - 979-8-3315-4364-8 U6 - https://doi.org/10.1109/CVPR52734.2025.02410 N1 - Die Preprint-Version ist ebenfalls in diesem Repositorium verzeichnet unter: https://opus4.kobv.de/opus4-oth-regensburg/8059 SP - 25874 EP - 25886 PB - IEEE ER - TY - INPR A1 - Rückert, Tobias A1 - Rauber, David A1 - Maerkl, Raphaela A1 - Klausmann, Leonard A1 - Yildiran, Suemeyye R. A1 - Gutbrod, Max A1 - Nunes, Danilo Weber A1 - Moreno, Alvaro Fernandez A1 - Luengo, Imanol A1 - Stoyanov, Danail A1 - Toussaint, Nicolas A1 - Cho, Enki A1 - Kim, Hyeon Bae A1 - Choo, Oh Sung A1 - Kim, Ka Young A1 - Kim, Seong Tae A1 - Arantes, Gonçalo A1 - Song, Kehan A1 - Zhu, Jianjun A1 - Xiong, Junchen A1 - Lin, Tingyi A1 - Kikuchi, Shunsuke A1 - Matsuzaki, Hiroki A1 - Kouno, Atsushi A1 - Manesco, João Renato Ribeiro A1 - Papa, João Paulo A1 - Choi, Tae-Min A1 - Jeong, Tae Kyeong A1 - Park, Juyoun A1 - Alabi, Oluwatosin A1 - Wei, Meng A1 - Vercauteren, Tom A1 - Wu, Runzhi A1 - Xu, Mengya A1 - an Wang, A1 - Bai, Long A1 - Ren, Hongliang A1 - Yamlahi, Amine A1 - Hennighausen, Jakob A1 - Maier-Hein, Lena A1 - Kondo, Satoshi A1 - Kasai, Satoshi A1 - Hirasawa, Kousuke A1 - Yang, Shu A1 - Wang, Yihui A1 - Chen, Hao A1 - Rodríguez, Santiago A1 - Aparicio, Nicolás A1 - Manrique, Leonardo A1 - Lyons, Juan Camilo A1 - Hosie, Olivia A1 - Ayobi, Nicolás A1 - Arbeláez, Pablo A1 - Li, Yiping A1 - Khalil, Yasmina Al A1 - Nasirihaghighi, Sahar A1 - Speidel, Stefanie A1 - Rückert, Daniel A1 - Feussner, Hubertus A1 - Wilhelm, Dirk A1 - Palm, Christoph T1 - Comparative validation of surgical phase recognition, instrument keypoint estimation, and instrument instance segmentation in endoscopy: Results of the PhaKIR 2024 challenge N2 - Reliable recognition and localization of surgical instruments in endoscopic video recordings are foundational for a wide range of applications in computer- and robot-assisted minimally invasive surgery (RAMIS), including surgical training, skill assessment, and autonomous assistance. However, robust performance under real-world conditions remains a significant challenge. Incorporating surgical context - such as the current procedural phase - has emerged as a promising strategy to improve robustness and interpretability. To address these challenges, we organized the Surgical Procedure Phase, Keypoint, and Instrument Recognition (PhaKIR) sub-challenge as part of the Endoscopic Vision (EndoVis) challenge at MICCAI 2024. We introduced a novel, multi-center dataset comprising thirteen full-length laparoscopic cholecystectomy videos collected from three distinct medical institutions, with unified annotations for three interrelated tasks: surgical phase recognition, instrument keypoint estimation, and instrument instance segmentation. Unlike existing datasets, ours enables joint investigation of instrument localization and procedural context within the same data while supporting the integration of temporal information across entire procedures. We report results and findings in accordance with the BIAS guidelines for biomedical image analysis challenges. The PhaKIR sub-challenge advances the field by providing a unique benchmark for developing temporally aware, context-driven methods in RAMIS and offers a high-quality resource to support future research in surgical scene understanding. Y1 - 2025 N1 - Der Aufsatz wurde peer-reviewed veröffentlicht und ist ebenfalls in diesem Repositorium verzeichnet unter: https://opus4.kobv.de/opus4-oth-regensburg/frontdoor/index/index/start/0/rows/10/sortfield/score/sortorder/desc/searchtype/simple/query/10.1016%2Fj.media.2026.103945/docId/8846 ER - TY - GEN A1 - Rückert, Tobias A1 - Rückert, Daniel A1 - Palm, Christoph T1 - Corrigendum to “Methods and datasets for segmentation of minimally invasive surgical instruments in endoscopic images and videos: A review of the state of the art” [Comput. Biol. Med. 169 (2024) 107929] T2 - Computers in Biology and Medicine N2 - The authors regret that the SAR-RARP50 dataset is missing from the description of publicly available datasets presented in Chapter 4. Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-70337 N1 - Aufsatz unter: https://opus4.kobv.de/opus4-oth-regensburg/frontdoor/index/index/docId/6983 PB - Elsevier ER - TY - JOUR A1 - Hammer, Simone A1 - Nunes, Danilo Weber A1 - Hammer, Michael A1 - Zeman, Florian A1 - Akers, Michael A1 - Götz, Andrea A1 - Balla, Annika A1 - Doppler, Michael Christian A1 - Fellner, Claudia A1 - Da Platz Batista Silva, Natascha A1 - Thurn, Sylvia A1 - Verloh, Niklas A1 - Stroszczynski, Christian A1 - Wohlgemuth, Walter Alexander A1 - Palm, Christoph A1 - Uller, Wibke T1 - Deep learning-based differentiation of peripheral high-flow and low-flow vascular malformations in T2-weighted short tau inversion recovery MRI JF - Clinical hemorheology and microcirculation N2 - BACKGROUND Differentiation of high-flow from low-flow vascular malformations (VMs) is crucial for therapeutic management of this orphan disease. OBJECTIVE A convolutional neural network (CNN) was evaluated for differentiation of peripheral vascular malformations (VMs) on T2-weighted short tau inversion recovery (STIR) MRI. METHODS 527 MRIs (386 low-flow and 141 high-flow VMs) were randomly divided into training, validation and test set for this single-center study. 1) Results of the CNN's diagnostic performance were compared with that of two expert and four junior radiologists. 2) The influence of CNN's prediction on the radiologists' performance and diagnostic certainty was evaluated. 3) Junior radiologists' performance after self-training was compared with that of the CNN. RESULTS Compared with the expert radiologists the CNN achieved similar accuracy (92% vs. 97%, p = 0.11), sensitivity (80% vs. 93%, p = 0.16) and specificity (97% vs. 100%, p = 0.50). In comparison to the junior radiologists, the CNN had a higher specificity and accuracy (97% vs. 80%, p <  0.001; 92% vs. 77%, p <  0.001). CNN assistance had no significant influence on their diagnostic performance and certainty. After self-training, the junior radiologists' specificity and accuracy improved and were comparable to that of the CNN. CONCLUSIONS Diagnostic performance of the CNN for differentiating high-flow from low-flow VM was comparable to that of expert radiologists. CNN did not significantly improve the simulated daily practice of junior radiologists, self-training was more effective. KW - magnetic resonance imaging KW - deep learning KW - Vascular malformation Y1 - 2024 U6 - https://doi.org/10.3233/CH-232071 SP - 1 EP - 15 PB - IOP Press ET - Pre-press ER - TY - GEN A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Probst, Andreas A1 - Scheppach, Markus W. A1 - Nagl, Sandra A1 - Schnoy, Elisabeth A1 - Römmele, Christoph A1 - Prinz, Friederike A1 - Schlottmann, Jakob A1 - Messmann, Helmut A1 - Palm, Christoph A1 - Ebigbo, Alanna T1 - Einfluss von Künstlicher Intelligenz auf die Performance von niedergelassenen Gastroenterolog:innen bei der Beurteilung von Barrett-Ösophagus T2 - Zeitschrift für Gastroenterologie N2 - Einleitung  Die Differenzierung zwischen nicht dysplastischem Barrett-Ösophagus (NDBE) und mit Barrett-Ösophagus assoziierten Neoplasien (BERN) während der endoskopischen Inspektion erfordert viel Expertise. Die frühe Diagnosestellung ist wichtig für die weitere Prognose des Barrett-Karzinoms. In Deutschland werden Patient:innen mit einem Barrett-Ösophagus (BE) in der Regel im niedergelassenen Sektor überwacht. Ziele  Ziel ist es, den Einfluss von einem auf Künstlicher Intelligenz (KI) basierenden klinischen Entscheidungsunterstützungssystems (CDSS) auf die Performance von niedergelassenen Gastroenterolog:innen (NG) bei der Evaluation von Barrett-Ösophagus (BE) zu untersuchen. Methodik  Es erfolgte die prospektive Sammlung von 96 unveränderten hochauflösenden Videos mit Fällen von Patient:innen mit histologisch bestätigtem NDBE und BERN. Alle eingeschlossenen Fälle enthielten mindestens zwei der folgenden Darstellungsmethoden: HD-Weißlichtendoskopie, Narrow Band Imaging oder Texture and Color Enhancement Imaging. Sechs NG von sechs unterschiedlichen Praxen wurden als Proband:innen eingeschlossen. Es erfolgte eine permutierte Block-Randomisierung der Videofälle in entweder Gruppe A oder Gruppe B. Gruppe A implizierte eine Evaluation des Falls durch Proband:innen zunächst ohne KI und anschließend mit KI als CDSS. In Gruppe B erfolgte die Evaluation in umgekehrter Reihenfolge. Anschließend erfolgte eine zufällige Wiedergabe der so entstandenen Subgruppen im Rahmen des Tests. Ergebnis  In diesem Test konnte ein von uns entwickeltes KI-System (Barrett-Ampel) eine Sensitivität von 92,2%, eine Spezifität von 68,9% und eine Accuracy von 81,3% erreichen. Mit der Hilfe von KI verbesserte sich die Sensitivität der NG von 64,1% auf 71,2% (p<0,001) und die Accuracy von 66,3% auf 70,8% (p=0,006) signifikant. Eine signifikante Verbesserung dieser Parameter zeigte sich ebenfalls, wenn die Proband:innen die Fälle zunächst ohne KI evaluierten (Gruppe A). Wurde der Fall jedoch als Erstes mit der Hilfe von KI evaluiert (Gruppe B), blieb die Performance nahezu konstant. Schlussfolgerung  Es konnte ein performantes KI-System zur Evaluation von BE entwickelt werden. NG verbessern sich bei der Evaluation von BE durch den Einsatz von KI. KW - Barrett-Ösophagus KW - Künstliche Intelligenz Y1 - 2023 UR - https://www.thieme-connect.de/products/ejournals/abstract/10.1055/s-0043-1771711 U6 - https://doi.org/10.1055/s-0043-1771711 VL - 61 IS - 8 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Meinikheim, Michael A1 - Yip, Hon Chi A1 - Lau, Louis Ho Shing A1 - Chiu, Philip Wai Yan A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Effekt eines Künstliche Intelligenz (KI) – Algorithmus auf die Gefäßdetektion bei third space Endoskopien T2 - Zeitschrift für Gastroenterologie N2 - Einleitung  Third space Endoskopieprozeduren wie die endoskopische Submukosadissektion (ESD) und die perorale endoskopische Myotomie (POEM) sind technisch anspruchsvoll und gehen mit untersucherabhängigen Komplikationen wie Blutungen und Perforationen einher. Grund hierfür ist die unabsichtliche Durchschneidung von submukosalen Blutgefäßen ohne präemptive Koagulation. Ziele Die Forschungsfrage, ob ein KI-Algorithmus die intraprozedurale Gefäßerkennung bei ESD und POEM unterstützen und damit Komplikationen wie Blutungen verhindern könnte, erscheint in Anbetracht des erfolgreichen Einsatzes von KI bei der Erkennung von Kolonpolypen interessant. Methoden  Auf 5470 Einzelbildern von 59 third space Endoscopievideos wurden submukosale Blutgefäße annotiert. Zusammen mit weiteren 179.681 nicht-annotierten Bildern wurde ein DeepLabv3+neuronales Netzwerk mit dem ECMT-Verfahren für semi-supervised learning trainiert, um Blutgefäße in Echtzeit erkennen zu können. Für die Evaluation wurde ein Videotest mit 101 Videoclips aus 15 vom Trainingsdatensatz separaten Prozeduren mit 200 vordefinierten Gefäßen erstellt. Die Gefäßdetektionsrate, -zeit und -dauer, definiert als der Prozentsatz an Einzelbildern eines Videos bezogen auf den Goldstandard, auf denen ein definiertes Gefäß erkannt wurde, wurden erhoben. Acht erfahrene Endoskopiker wurden mithilfe dieses Videotests im Hinblick auf Gefäßdetektion getestet, wobei eine Hälfte der Videos nativ, die andere Hälfte nach Markierung durch den KI-Algorithmus angesehen wurde. Ergebnisse  Der mittlere Dice Score des Algorithmus für Blutgefäße war 68%. Die mittlere Gefäßdetektionsrate im Videotest lag bei 94% (96% für ESD; 74% für POEM). Die mediane Gefäßdetektionszeit des Algorithmus lag bei 0,32 Sekunden (0,3 Sekunden für ESD; 0,62 Sekunden für POEM). Die mittlere Gefäßdetektionsdauer lag bei 59,1% (60,6% für ESD; 44,8% für POEM) des Goldstandards. Alle Endoskopiker hatten mit KI-Unterstützung eine höhere Gefäßdetektionsrate als ohne KI. Die mittlere Gefäßdetektionsrate ohne KI lag bei 56,4%, mit KI bei 71,2% (p<0.001). Schlussfolgerung  KI-Unterstützung war mit einer statistisch signifikant höheren Gefäßdetektionsrate vergesellschaftet. Die mediane Gefäßdetektionszeit von deutlich unter einer Sekunde sowie eine Gefäßdetektionsdauer von größer 50% des Goldstandards wurden für den klinischen Einsatz als ausreichend erachtet. In prospektiven Anwendungsstudien sollte der KI-Algorithmus auf klinische Relevanz getestet werden. KW - Künstliche Intelligenz Y1 - 2023 U6 - https://doi.org/10.1055/s-0043-1771980 VL - 61 IS - 08 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Muzalyova, Anna A1 - Rauber, David A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Yip, Hon Chi A1 - Lau, Louis Ho Shing A1 - Gölder, Stefan Karl A1 - Schmidt, Arthur A1 - Kouladouros, Konstantinos A1 - Abdelhafez, Mohamed A1 - Walter, B. A1 - Meinikheim, Michael A1 - Chiu, Philip Wai Yan A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Künstliche Intelligenz erhöht die Gefäßerkennung von Endoskopikern bei third space Endoskopie T2 - Zeitschrift für Gastroenterologie N2 - Einleitung: Künstliche Intelligenz (KI)-Algorithmen unterstützen Endoskopiker bei der Erkennung und Charakterisierung von Kolonpolypen in der klinischen Praxis und führen zu einer Erhöhung der Adenomdetektionsrate. Auch bei therapeutischen Maßnahmen wie der endoskopischen Submukosadissektion (ESD) könne relevante anatomische Strukturen durch KI mit hoher Genauigkeit erkannt und im endoskopischen Bild in Echtzeit markiert werden. Der Effekt einer solchen Applikation auf die Gefäßdetektion von Endoskopikern ist bislang nicht erforscht. Ziele:  In dieser Studie wurde der Effekt eines KI-Algorithmus zur Echtzeit-Gefäßmarkierung bei ESD auf die Gefäßdetektionsrate von Endoskopikern untersucht. Methodik:  59 third space Endoskopievideos wurde aus der Datenbank des Universitätsklinikums Augsburg extrahiert. Auf 5470 Einzelbildern dieser Untersuchungen wurde submukosale Blutgefäße annotiert. Zusammen mit weiteren 179681 unmarkierten Bildern wurde ein DeepLabV3+ neuronales Netzwerk mit einer semi-supervised learning Methode darin trainiert, submukosale Blutgefäße auf dem endoskopischen Bild zu erkennen und in Echtzeit einzuzeichnen. Anhand eines Videotests mit 101 Videoclips und 200 vordefinierten Blutgefäßen wurden 19 Endoskopiker mit und ohne KI Unterstützung getestet. Ergebnis:  Der Algorithmus erkannte in dem Videotest 93.5% der Gefäße in einer Detektionszeit von im Median 0,3 Sekunden. Die Gefäßdetektionsrate von Endoskopikern erhöhte sich durch KI Unterstützung von 56,4% auf 72,4% (p<0.001). Die Gefäßdetektionszeit reduzierte sich durch KI-Unterstützung von 6,7 auf 5.2 Sekunden (p<0.001). Der Algorithmus zeigte eine Rate an falsch positiven Detektionen in 4.5% der Einzelbilder. Falsch positiv erkannte Strukturen wurde kürzer detektiert, als richtig positive (0.7 und 6.0 Sekunden, p<0.001). Schlussfolgerung:  KI Unterstützung führte zu einer erhöhten Gefäßdetektionsrate und schnelleren Gefäßdetektionszeit von Endoskopikern. Ein möglicher klinischer Effekt auf die intraprozedurale Komplikationsrate oder Operationszeit könnte in prospektiven Studien ermittelt werden. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1790087 VL - 62 IS - 09 SP - e830 PB - Georg Thieme Verlag KG ER - TY - GEN A1 - Roser, David A1 - Meinikheim, Michael A1 - Mendel, Robert A1 - Palm, Christoph A1 - Muzalyova, Anna A1 - Rauber, David A1 - Rückert, Tobias A1 - Parsa, Nasim A1 - Byrne, Michael F. A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Mensch-Maschine-Interaktion: Einfluss künstlicher Intelligenz auf das diagnostische Vertrauen von Endoskopikern bei der Beurteilung des Barrett-Ösophagus T2 - Zeitschrift für Gastroenterologie N2 - Ziele:  Das Ziel der Studie war es, den Einfluss von KI auf die diagnostische Sicherheit (Konfidenzniveau) von Endoskopikern anhand von BÖ-Videos zu untersuchen und mögliche Korrelationen mit der Untersuchungsqualität zu erforschen. Methodik:  22 Endoskopiker aus zwölf Zentren mit unterschiedlicher Barrett-Erfahrung untersuchten 96 standardisierte Endoskopievideos. Die Untersucher wurden in Experten und Nicht-Experten eingeteilt und nach dem Zufallsprinzip für die Bewertung der Videos mit oder ohne KI eingeteilt. Die Teilnehmer wurden in zwei Gruppen aufgeteilt: Arm A bewertete zunächst Videos ohne KI und dann mit KI, während Arm B die umgekehrte Reihenfolge einhielt. Die Untersucher hatten die Aufgabe, BÖ-assoziierte Neoplasien zu erkennen und ihr Konfidenzniveau sowohl mit als auch ohne KI auf einer Skala von 0 bis 9 anzugeben. Ergebnis:  In Arm A erhöhte der Einsatz von KI das Konfidenzniveau bei beiden signifikant (p<0.001). Bemerkenswert ist, dass jedoch nur Nicht-Experten durch die KI eine signifikante Verbesserung der Sensitivität und Spezifität (p<0.001 bzw. p<0.05) erfuhren. Während Experten ohne KI im Vergleich zu Nicht-Experten mit KI ein höheres Konfidenzniveau aufwiesen, gab es keinen signifikanten Unterschied in der Genauigkeit. In Arm B zeigten beide Gruppen eine signifikante Abnahme des Konfidenzniveaus (p<0.001) bei gleichbleibender Genauigkeit. Darüber hinaus wurden in 9% der Entscheidungen trotz korrekter KI eine falsche Wahl getroffen. Schlussfolgerung:  Der Einsatz künstlicher Intelligenz steigerte das Konfidenzniveau sowohl bei Experten als auch bei Nicht-Experten signifikant – ein Effekt, der im Studienmodell reversibel war. Darüber hinaus wiesen Experten mit oder ohne KI durchweg höhere Konfidenzniveaus auf als Nicht-Experten mit KI, trotz vergleichbarer Ergebnisse. Zudem konnte beobachtet werden, dass die Untersucher in 9% der Fälle die KI zuungunsten des Patienten ignorierten. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1789656 VL - 62 IS - 09 SP - e575 EP - e576 PB - Georg Thieme Verlag KG ER - TY - GEN A1 - Scheppach, Markus W. A1 - Nunes, Danilo Weber A1 - Arizi, X. A1 - Rauber, David A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Intraoperative Phasenerkennung bei endoskopischer Submukosadissektion mit Hilfe von künstlicher Intelligenz T2 - Zeitschrift für Gastroenterologie N2 - Einleitung:  Künstliche Intelligenz (KI) wird in der Endoskopie des Gastrointestinaltraktes zur Erkennung und Charakterisierung von Kolonpolypen eingesetzt. Die Rolle von KI bei therapeutischen Maßnahmen wurde noch nicht eingehend untersucht. Eine intraprozedurale Phasenerkennung bei endoskopischer Submukoasdissektion (ESD) könnte die Erhebung von Qualitätsindikatoren ermöglichen. Weiterhin könnte diese Technologie zu einem tieferen Verständnis über die Eigenschaften der Prozedur führen und weiterführende Applikationen zur automatischen Dokumentation oder standardisiertem Training vorbereiten. Ziele: Ziel dieser Studie war die Entwicklung eines KI Algorithmus zur intraprozeduralen Phasenerkennung bei endoskopischer Submukosadissektion. Methodik:  2071546 Einzelbilder aus 27 ESD Videos in voller Länge wurden für die übergeordneten Klassen Diagnostik, Markierung, Nadelinjektion, Dissektion und Blutung, sowie die untergeordneten Klassen Endoskop-Manipulation, Injektion und Applikation von elektrischem Strom annotiert. Mit einem Trainingsdatensatz (898440 Einzelbilder, 17 ESDs) wurde ein Video Swin Transformer mit uniformer Stichprobenentnahme trainiert und intern validiert (769523 Einzelbilder, 6 ESDs). Neben der internen Validierung wurde der Algorithmus anhand von einem separaten Testdatensatz (403583 Einzelbilder, 4 ESDs) evaluiert. Ergebnis:  Der F1 Score des Algorithmus für alle Klassen lag in der internen Validierung bei 83%, in dem separaten Test bei 90%. Anhand des separaten Tests wurden true positive (TP)-Raten für Diagnostik, Markierung, Nadelinjektion, Dissektion und Blutung von 100%, 100%, 96%, 97% und 93% ermittelt. Für Endoskopmanipulation, Injektion und Applikation von Elektrizität lagen die TP-Raten bei 92%, 98% und 91%. Schlussfolgerung:  Der entwickelte Algorithmus klassifizierte ESD Videos in voller Länge und anhand jedes einzelnen Bildes mit hoher Genauigkeit. Zukünftige Forschungsvorhaben könnten intraoperative Qualitätsindikatioren auf Basis dieser Informationen entwickeln und eine automatisierte Dokumentation ermöglichen. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1790084 VL - 62 IS - 09 SP - e828 PB - Georg Thieme Verlag KG ER - TY - GEN A1 - Zellmer, Stephan A1 - Rauber, David A1 - Probst, Andreas A1 - Weber, Tobias A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Schnoy, Elisabeth A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Verwendung künstlicher Intelligenz bei der Detektion der Papilla duodeni major T2 - Zeitschrift für Gastroenterologie N2 - Einleitung Die Endoskopische Retrograde Cholangiopankreatikographie (ERCP) ist der Goldstandard in der Diagnostik und Therapie von Erkrankungen des pankreatobiliären Trakts. Jedoch ist sie technisch sehr anspruchsvoll und weist eine vergleichsweise hohe Komplikationsrate auf. Ziele  In der vorliegenden Machbarkeitsstudie soll geprüft werden, ob mithilfe eines Deep-learning-Algorithmus die Papille und das Ostium zuverlässig detektiert werden können und somit für Endoskopiker mit geringer Erfahrung ein geeignetes Hilfsmittel, insbesondere für die Ausbildungssituation, darstellen könnten. Methodik Wir betrachteten insgesamt 606 Bilddatensätze von 65 Patienten. In diesen wurde sowohl die Papilla duodeni major als auch das Ostium segmentiert. Anschließend wurde eine neuronales Netz mittels eines Deep-learning-Algorithmus trainiert. Außerdem erfolgte eine 5-fache Kreuzvaldierung. Ergebnisse Bei einer 5-fachen Kreuzvaldierung auf den 606 gelabelten Daten konnte für die Klasse Papille eine F1-Wert von 0,7908, eine Sensitivität von 0,7943 und eine Spezifität von 0,9785 erreicht werden, für die Klasse Ostium eine F1-Wert von 0,5538, eine Sensitivität von 0,5094 und eine Spezifität von 0,9970 (vgl. [Tab. 1]). Unabhängig von der Klasse zeigte sich gemittelt (Klasse Papille und Klasse Ostium) ein F1-Wert von 0,6673, eine Sensitivität von 0,6519 und eine Spezifität von 0,9877 (vgl. [Tab. 2]). Schlussfolgerung  In vorliegende Machbarkeitsstudie konnte das neuronale Netz die Papilla duodeni major mit einer hohen Sensitivität und sehr hohen Spezifität identifizieren. Bei der Detektion des Ostiums war die Sensitivität deutlich geringer. Zukünftig soll das das neuronale Netz mit mehr Daten trainiert werden. Außerdem ist geplant, den Algorithmus auch auf Videos anzuwenden. Somit könnte langfristig ein geeignetes Hilfsmittel für die ERCP etabliert werden. KW - Künstliche Intelligenz Y1 - 2023 UR - https://www.thieme-connect.de/products/ejournals/abstract/10.1055/s-0043-1772000 U6 - https://doi.org/10.1055/s-0043-1772000 VL - 61 IS - 08 SP - e539 EP - e540 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Rueckert, Tobias A1 - Rauber, David A1 - Maerkl, Raphaela A1 - Klausmann, Leonard A1 - Yildiran, Suemeyye R. A1 - Gutbrod, Max A1 - Nunes, Danilo Weber A1 - Moreno, Alvaro Fernandez A1 - Luengo, Imanol A1 - Stoyanov, Danail A1 - Toussaint, Nicolas A1 - Cho, Enki A1 - Kim, Hyeon Bae A1 - Choo, Oh Sung A1 - Kim, Ka Young A1 - Kim, Seong Tae A1 - Arantes, Gonçalo A1 - Song, Kehan A1 - Zhu, Jianjun A1 - Xiong, Junchen A1 - Lin, Tingyi A1 - Kikuchi, Shunsuke A1 - Matsuzaki, Hiroki A1 - Kouno, Atsushi A1 - Manesco, João Renato Ribeiro A1 - Papa, João Paulo A1 - Choi, Tae-Min A1 - Jeong, Tae Kyeong A1 - Park, Juyoun A1 - Alabi, Oluwatosin A1 - Wei, Meng A1 - Vercauteren, Tom A1 - Wu, Runzhi A1 - Xu, Mengya A1 - Wang, An A1 - Bai, Long A1 - Ren, Hongliang A1 - Yamlahi, Amine A1 - Hennighausen, Jakob A1 - Maier-Hein, Lena A1 - Kondo, Satoshi A1 - Kasai, Satoshi A1 - Hirasawa, Kousuke A1 - Yang, Shu A1 - Wang, Yihui A1 - Chen, Hao A1 - Rodríguez, Santiago A1 - Aparicio, Nicolás A1 - Manrique, Leonardo A1 - Palm, Christoph A1 - Wilhelm, Dirk A1 - Feussner, Hubertus A1 - Rueckert, Daniel A1 - Speidel, Stefanie A1 - Nasirihaghighi, Sahar A1 - Al Khalil, Yasmina A1 - Li, Yiping A1 - Arbeláez, Pablo A1 - Ayobi, Nicolás A1 - Hosie, Olivia A1 - Lyons, Juan Camilo T1 - Comparative validation of surgical phase recognition, instrument keypoint estimation, and instrument instance segmentation in endoscopy: Results of the PhaKIR 2024 challenge JF - Medical Image Analysis N2 - Reliable recognition and localization of surgical instruments in endoscopic video recordings are foundational for a wide range of applications in computer- and robot-assisted minimally invasive surgery (RAMIS), including surgical training, skill assessment, and autonomous assistance. However, robust performance under real-world conditions remains a significant challenge. Incorporating surgical context – such as the current procedural phase – has emerged as a promising strategy to improve robustness and interpretability. To address these challenges, we organized the Surgical Procedure Phase, Keypoint, and Instrument Recognition (PhaKIR) sub-challenge as part of the Endoscopic Vision (EndoVis) challenge at MICCAI 2024. We introduced a novel, multi-center dataset comprising thirteen full-length laparoscopic cholecystectomy videos collected from three distinct medical institutions, with unified annotations for three interrelated tasks: surgical phase recognition, instrument keypoint estimation, and instrument instance segmentation. Unlike existing datasets, ours enables joint investigation of instrument localization and procedural context within the same data while supporting the integration of temporal information across entire procedures. We report results and findings in accordance with the BIAS guidelines for biomedical image analysis challenges. The PhaKIR sub-challenge advances the field by providing a unique benchmark for developing temporally aware, context-driven methods in RAMIS and offers a high-quality resource to support future research in surgical scene understanding. KW - Surgical phase recognition KW - Instrument keypoint estimation KW - Instrument instance segmentation KW - Robot-assisted surgery Y1 - 2026 U6 - https://doi.org/10.1016/j.media.2026.103945 SN - 1361-8415 N1 - Corresponding author der OTH Regensburg: Tobias Rueckert Die Preprint-Version ist ebenfalls in diesem Repositorium verzeichnet unter: https://opus4.kobv.de/opus4-oth-regensburg/solrsearch/index/search/start/0/rows/10/sortfield/score/sortorder/desc/searchtype/simple/query/2507.16559 VL - 109 PB - Elsevier ER - TY - GEN A1 - Rueckert, Tobias A1 - Rauber, David A1 - Klausmann, Leonard A1 - Gutbrod, Max A1 - Rueckert, Daniel A1 - Feussner, Hubertus A1 - Wilhelm, Dirk A1 - Palm, Christoph T1 - PhaKIR Dataset - Surgical Procedure Phase, Keypoint, and Instrument Recognition [Data set] N2 - Note: A script for extracting the individual frames from the video files while preserving the challenge-compliant directory structure and frame-to-mask naming conventions is available on GitHub and can be accessed here: https://github.com/remic-othr/PhaKIR_Dataset. The dataset is described in the following publications: Rueckert, Tobias et al.: Comparative validation of surgical phase recognition, instrument keypoint estimation, and instrument instance segmentation in endoscopy: Results of the PhaKIR 2024 challenge. arXiv preprint, https://arxiv.org/abs/2507.16559. 2025. Rueckert, Tobias et al.: Video Dataset for Surgical Phase, Keypoint, and Instrument Recognition in Laparoscopic Surgery (PhaKIR). arXiv preprint, https://arxiv.org/abs/2511.06549. 2025. The proposed dataset was used as the training dataset in the PhaKIR challenge (https://phakir.re-mic.de/) as part of EndoVis-2024 at MICCAI 2024 and consists of eight real-world videos of human cholecystectomies ranging from 23 to 60 minutes in duration. The procedures were performed by experienced physicians, and the videos were recorded in three hospitals. In addition to existing datasets, our annotations provide pixel-wise instance segmentation masks of surgical instruments for a total of 19 categories, coordinates of relevant instrument keypoints (instrument tip(s), shaft-tip transition, shaft), both at an interval of one frame per second, and specifications regarding the intervention phases for a total of eight different phase categories for each individual frame in one dataset and thus comprehensively cover instrument localization and the context of the operation. Furthermore, the provision of the complete video sequences offers the opportunity to include the temporal information regarding the respective tasks and thus further optimize the resulting methods and outcomes. Y1 - 2025 U6 - https://doi.org/10.5281/zenodo.15740620 ER - TY - GEN A1 - Gutbrod, Max A1 - Rauber, David A1 - Weber Nunes, Danilo A1 - Palm, Christoph T1 - A cleaned subset of the first five CATARACTS test videos [Data set] N2 - This dataset is a subset of the original CATARACTS test dataset and is used by the OpenMIBOOD framework to evaluate a specific out-of-distribution setting. When using this dataset, it is mandatory to cite the corresponding publication (OpenMIBOOD (10.1109/CVPR52734.2025.02410)) and follow the acknowledgement and citation requirements of the original dataset (CATARACTS). The original CATARACTS dataset (associated publication,Homepage) consists of 50 videos of cataract surgeries, split into 25 train and 25 test videos. This subset contains the frames of the first 5 test videos. Further, black frames at the beginning of each video were removed. Y1 - 2025 U6 - https://doi.org/10.5281/zenodo.14924735 N1 - Related works: Is derived from: Dataset: 10.21227/ac97-8m18 (DOI) Software: Repository URL: https://github.com/remic-othr/OpenMIBOOD ER - TY - GEN A1 - Gutbrod, Max A1 - Rauber, David A1 - Weber Nunes, Danilo A1 - Palm, Christoph T1 - Cropped single instrument frames subset from Cholec80 [Data set] N2 - This dataset is a subset of the original Cholec80 dataset and is used by the OpenMIBOOD framework to evaluate a specific out-of-distribution setting. When using this dataset, it is mandatory to cite the corresponding publication (OpenMIBOOD) and to follow the acknowledgement and citation requirements of the original dataset (Cholec80). The original Cholec80 dataset (associated paper,Homepage) consists of 80 cholecystectomy surgery videos recorded at 25 fps, performed by 13 surgeons. It includes phase annotations (25 fps) and tool presence labels (1 fps), with phase definitions provided by a senior surgeon. A tool is considered present if at least half of its tip is visible. The dataset categorizes tools into seven types: Grasper, Bipolar, Hook, Scissors, Clipper, Irrigator, and Specimen bag. Multiple tools may be present in each frame. Additionally, 76 of the 80 videos exhibit a strong black vignette. For this dataset subset, frames were extracted based on tool presence labels, selecting only those containing Grasper, Bipolar, Hook, or Clipper while ensuring that only a single tool appears per frame. To enhance visual consistency, the black vignette was removed by extracting an inner rectangular region, where applicable. KW - Tool Presence Detection KW - Cholecystectomy KW - Laparoscopic KW - Deep Learning KW - Out-Of-Distribution Detection Y1 - 2025 U6 - https://doi.org/10.5281/zenodo.14921670 N1 - Related works Is derived from Journal article: 10.1109/TMI.2016.2593957 Software Repository URL https://github.com/remic-othr/OpenMIBOOD ER - TY - GEN A1 - Gutbrod, Max A1 - Rauber, David A1 - Weber Nunes, Danilo A1 - Palm, Christoph T1 - OpenMIBOOD's classification models for the MIDOG, PhaKIR, and OASIS-3 benchmarks [Data set] N2 - These models are provided for evaluating post-hoc out-of-distribution methods on the three OpenMIBOOD benchmarks: MIDOG, PhaKIR, and OASIS-3. When using these models, make sure to give appropriate credit and cite the OpenMIBOOD publication. Y1 - 2025 U6 - https://doi.org/10.5281/zenodo.14982267 N1 - Software Repository URL https://github.com/remic-othr/OpenMIBOOD ER - TY - JOUR A1 - de Souza Júnior, Luis Antonio A1 - Pacheco, André Georghton Cardoso A1 - Oliveira dos Santos, Thiago A1 - Fogos da Rocha, Wyctor A1 - Bouzon, Pedro Henrique A1 - Palm, Christoph A1 - Papa, João Paulo T1 - LiwTERM-r: a Revised Lightweight Transformer-based Model for Multimodal Skin Lesion Detection Robust to Incomplete Input JF - Journal of the Brazilian Computer Society N2 - As the most common type of cancer in the world, skin cancer accounts for approximately 30% of all diagnosed tumor-based lesions. Early diagnosis can reduce mortality and prevent disfiguring in different skin regions. With the application of machine learning techniques in recent years, especially deep learning, promising results in this task could be achieved, presenting studies demonstrating that the combination of patients’ clinical anamneses and images of the injured lesion is essential for improving the correct classification of skin lesions. Despite that, meaningful use of anamneses with multiple collected images of the same skin lesion is mandatory, requiring further investigation. Thus, this project aims to contribute to developing multimodal machine learning-based models to solve the skin lesion classification problem by employing a lightweight transformer model that is robust to missing clinical information input. As a main hypothesis, models can be fed by multiple images from different sources as input along with clinical anamneses from the patient’s historical evaluations, leading to a more factual and trustworthy diagnosis. Our model deals with the not-trivial task of combining images and clinical information concerning the skin lesions in a lightweight transformer architecture that does not demand high computation resources or even all the information from the anamneses but still presents competitive classification results. KW - Deep learning KW - Skin Lesion Detection KW - Transformers KW - Lightweight Architectures Y1 - 2026 U6 - https://doi.org/10.5753/jbcs.2026.5871 VL - 32 IS - 1 PB - Brazilian Computer Society ER - TY - GEN A1 - Klausmann, Leonard A1 - Rueckert, Tobias A1 - Rauber, David A1 - Maerkl, Raphaela A1 - Yildiran, Suemeyye R. A1 - Gutbrod, Max A1 - Palm, Christoph ED - Handels, Heinz ED - Breininger, Katharina ED - Deserno, Thomas M. ED - Maier, Andreas ED - Maier-Hein, Klaus H. ED - Palm, Christoph ED - Tolxdorff, Thomas T1 - Abstract: DIY Challenge Blueprint BT - from organization to technical implementation in Biomedical Image Analysis T2 - Bildverarbeitung für die Medizin 2025: Proceedings, German Conference on Medical Image Computing, Lübeck March 15-17, 2026 N2 - The high cost of challenge platforms prevents many people from organizing their own competitions. The do-it-yourself (DIY) challenge blueprint [1] allows you to host your own biomedical AI benchmark challenge. Our DIY approach circumvents the current constraints of commercial challenge platforms. A sovereign, extensible and cost-efficient deployment is provided via containerised, identity-managed and reproducible pipelines. Focus lies on GDPR-compliant hosting via infrastructure-as-code, automated evaluation, modular orchestration, and role-based identity and access management. The framework integrates Docker-based execution and standardised interfaces for task definitions, dataset curation and evaluation. All in all it is designed to be flexible and modular, as demonstrated in the MICCAI 2024 PhaKIR challenge [2, 3]. In this case study, different medical tasks on a multicentre laparoscopic dataset with framewise labels for phases and spatial annotations for instruments across fulllength videos were supported. This case study empirically validates the DIY challenge blueprint as a reproducible and customizable challenge-hosting infrastructure. The full code can be found at https://github.com/remic-othr/PhaKIR_DIY. KW - Bildverarbeitung Y1 - 2026 U6 - https://doi.org/10.1007/978-3-658-51100-5_27 SP - 131 EP - 131 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Gutbrod, Max A1 - Rauber, David A1 - Palm, Christoph ED - Handels, Heinz ED - Breininger, Katharina ED - Deserno, Thomas M. ED - Maier, Andreas ED - Maier-Hein, Klaus H. ED - Palm, Christoph ED - Tolxdorff, Thomas T1 - Improving Generalization in Mitotic Cell Detection via Domain Transformations T2 - Bildverarbeitung für die Medizin 2025: Proceedings, German Conference on Medical Image Computing, Lübeck March 15-17, 2026 N2 - We address domain generalization (DG) in mitotic-cell (MC) detection by combining a β-variational autoencoder (VAE) for domain transformations with feature-space alignment together with an object detector. The β-VAE synthesizes domain-transformed images, and the detector is trained to map originals and their transformed counterparts to equal representations. On the MIDOG++ dataset, this approach improves out-of-domain detection F1 scores by 7 and 3 percentage points compared to the color-variation augmentation and stain-normalization baselines. Results further suggest that morphology shifts hinder generalization more than stain shifts. KW - Künstliche Intelligenz KW - Bildverarbeitung Y1 - 2026 U6 - https://doi.org/10.1007/978-3-658-51100-5_71 SP - 362 EP - 367 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Wallner, M. A1 - Gutbrod, Max A1 - Rauber, David A1 - Ebigbo, Alanna A1 - Probst, Andreas A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Roser, David T1 - KI-gestützte Detektion und Segmentierung von Magenkarzinomen in westlichen endoskopischen Bilddaten anhand eines fine-tuned Deep-Learning Ansatzes JF - Zeitschrift für Gastroenterologie N2 - Diese vorläufige monozentrische Studie zeigt, dass ein aus einem Barrett-Ösophagus-KI-System feinjustiertes Deep-Learning-Modell Magenkarzinome in westlichen multimodalen endoskopischen Bilddaten zuverlässig detektieren und präzise segmentieren kann. Die hohe Segmentierungsgenauigkeit und Detektionssensitivität über verschiedene Bildmodalitäten hinweg unterstreichen die Machbarkeit eines pathologiegestützten KI-Ansatzes auch in einer westlichen Niedriginzidenzpopulation. Aufgrund der ausschließlichen Verwendung von Bildern mit sichtbaren Tumoren lassen sich keine Aussagen zur Spezifität treffen; eine Übertragbarkeit auf Screening- oder Mischkollektive ist daher limitiert. Weitere Studien mit a) größerem Datensatz inklusive Videodaten, b) externer Validierung an einer multizentrischen westlichen Kohorte, sowie c) Anwendung und Prüfung an nicht-neoplastischen Vergleichsbildern oder anderen Pathologien sind erforderlich. Nach unserem Kenntnisstand zählt dieses System zu den ersten in einer westlichen Population entwickelten endoskopischen KI-Ansätzen zur Magenkarzinomdetektion, und zu wenigen, die vollständige ESD-präparatbasierte Referenzdaten für Training und Validierung nutzen. Y1 - 2026 U6 - https://doi.org/10.1055/s-0046-1817751 VL - 64 IS - 03 SP - e64 EP - e65 PB - Thieme ER -