TY - JOUR A1 - Beyer, Thomas A1 - Weigert, Markus A1 - Quick, Harald H. A1 - Pietrzyk, Uwe A1 - Vogt, Florian A1 - Palm, Christoph A1 - Antoch, Gerald A1 - Müller, Stefan P. A1 - Bockisch, Andreas T1 - MR-based attenuation correction for torso-PET/MR imaging BT - pitfalls in mapping MR to CT data JF - European Journal of Nuclear Medicine and Molecular Imaging N2 - Purpose MR-based attenuation correction (AC) will become an integral part of combined PET/MR systems. Here, we propose a toolbox to validate MR-AC of clinical PET/MRI data sets. Methods Torso scans of ten patients were acquired on a combined PET/CT and on a 1.5-T MRI system. MR-based attenuation data were derived from the CT following MR–CT image co-registration and subsequent histogram matching. PET images were reconstructed after CT- (PET/CT) and MR-based AC (PET/MRI). Lesion-to-background (L/B) ratios were estimated on PET/CT and PET/MRI. Results MR–CT histogram matching leads to a mean voxel intensity difference in the CT- and MR-based attenuation images of 12% (max). Mean differences between PET/MRI and PET/CT were 19% (max). L/B ratios were similar except for the lung where local misregistration and intensity transformation leads to a biased PET/MRI. Conclusion Our toolbox can be used to study pitfalls in MR-AC. We found that co-registration accuracy and pixel value transformation determine the accuracy of PET/MRI. KW - PET/MRI KW - PET/CT KW - Attenuation correction KW - Kernspintomografie KW - Positronen-Emissions-Tomografie KW - Schwächung Y1 - 2008 U6 - https://doi.org/10.1007/s00259-008-0734-0 VL - 35 IS - 6 SP - 1142 EP - 1146 ER - TY - JOUR A1 - Knödler, Leonard A1 - Baecher, Helena A1 - Kauke-Navarro, Martin A1 - Prantl, Lukas A1 - Machens, Hans-Günther A1 - Scheuermann, Philipp A1 - Palm, Christoph A1 - Baumann, Raphael A1 - Kehrer, Andreas A1 - Panayi, Adriana C. A1 - Knoedler, Samuel T1 - Towards a Reliable and Rapid Automated Grading System in Facial Palsy Patients: Facial Palsy Surgery Meets Computer Science JF - Journal of Clinical Medicine N2 - Background: Reliable, time- and cost-effective, and clinician-friendly diagnostic tools are cornerstones in facial palsy (FP) patient management. Different automated FP grading systems have been developed but revealed persisting downsides such as insufficient accuracy and cost-intensive hardware. We aimed to overcome these barriers and programmed an automated grading system for FP patients utilizing the House and Brackmann scale (HBS). Methods: Image datasets of 86 patients seen at the Department of Plastic, Hand, and Reconstructive Surgery at the University Hospital Regensburg, Germany, between June 2017 and May 2021, were used to train the neural network and evaluate its accuracy. Nine facial poses per patient were analyzed by the algorithm. Results: The algorithm showed an accuracy of 100%. Oversampling did not result in altered outcomes, while the direct form displayed superior accuracy levels when compared to the modular classification form (n = 86; 100% vs. 99%). The Early Fusion technique was linked to improved accuracy outcomes in comparison to the Late Fusion and sequential method (n = 86; 100% vs. 96% vs. 97%). Conclusions: Our automated FP grading system combines high-level accuracy with cost- and time-effectiveness. Our algorithm may accelerate the grading process in FP patients and facilitate the FP surgeon’s workflow. Y1 - 2022 U6 - https://doi.org/10.3390/jcm11174998 VL - 11 IS - 17 PB - MDPI CY - Basel ER - TY - JOUR A1 - Souza Jr., Luis Antonio de A1 - Palm, Christoph A1 - Mendel, Robert A1 - Hook, Christian A1 - Ebigbo, Alanna A1 - Probst, Andreas A1 - Messmann, Helmut A1 - Weber, Silke A. T. A1 - Papa, João Paulo T1 - A survey on Barrett's esophagus analysis using machine learning JF - Computers in Biology and Medicine N2 - This work presents a systematic review concerning recent studies and technologies of machine learning for Barrett's esophagus (BE) diagnosis and treatment. The use of artificial intelligence is a brand new and promising way to evaluate such disease. We compile some works published at some well-established databases, such as Science Direct, IEEEXplore, PubMed, Plos One, Multidisciplinary Digital Publishing Institute (MDPI), Association for Computing Machinery (ACM), Springer, and Hindawi Publishing Corporation. Each selected work has been analyzed to present its objective, methodology, and results. The BE progression to dysplasia or adenocarcinoma shows a complex pattern to be detected during endoscopic surveillance. Therefore, it is valuable to assist its diagnosis and automatic identification using computer analysis. The evaluation of the BE dysplasia can be performed through manual or automated segmentation through machine learning techniques. Finally, in this survey, we reviewed recent studies focused on the automatic detection of the neoplastic region for classification purposes using machine learning methods. KW - Speiseröhrenkrankheit KW - Diagnose KW - Mustererkennung KW - Maschinelles Lernen KW - Literaturbericht KW - Barrett's esophagus KW - Machine learning KW - Adenocarcinoma KW - Image processing KW - Pattern recognition KW - Computer-aided diagnosis Y1 - 2018 U6 - https://doi.org/10.1016/j.compbiomed.2018.03.014 VL - 96 SP - 203 EP - 213 PB - Elsevier ER - TY - JOUR A1 - Ott, Tankred A1 - Palm, Christoph A1 - Vogt, Robert A1 - Oberprieler, Christoph T1 - GinJinn: An object-detection pipeline for automated feature extraction from herbarium specimens JF - Applications in Plant Sciences N2 - PREMISE: The generation of morphological data in evolutionary, taxonomic, and ecological studies of plants using herbarium material has traditionally been a labor-intensive task. Recent progress in machine learning using deep artificial neural networks (deep learning) for image classification and object detection has facilitated the establishment of a pipeline for the automatic recognition and extraction of relevant structures in images of herbarium specimens. METHODS AND RESULTS: We implemented an extendable pipeline based on state-of-the-art deep-learning object-detection methods to collect leaf images from herbarium specimens of two species of the genus Leucanthemum. Using 183 specimens as the training data set, our pipeline extracted one or more intact leaves in 95% of the 61 test images. CONCLUSIONS: We establish GinJinn as a deep-learning object-detection tool for the automatic recognition and extraction of individual leaves or other structures from herbarium specimens. Our pipeline offers greater flexibility and a lower entrance barrier than previous image-processing approaches based on hand-crafted features. KW - Deep Learning KW - herbarium specimens KW - object detection KW - visual recognition KW - Deep Learning KW - Objekterkennung KW - Maschinelles Sehen KW - Pflanzen Y1 - 2020 U6 - https://doi.org/10.1002/aps3.11351 SN - 2168-0450 VL - 8 IS - 6 SP - e11351 PB - Wiley, Botanical Society of America ER - TY - JOUR A1 - Ebigbo, Alanna A1 - Palm, Christoph A1 - Probst, Andreas A1 - Mendel, Robert A1 - Manzeneder, Johannes A1 - Prinz, Friederike A1 - Souza Jr., Luis Antonio de A1 - Papa, João Paulo A1 - Siersema, Peter A1 - Messmann, Helmut T1 - A technical review of artificial intelligence as applied to gastrointestinal endoscopy: clarifying the terminology JF - Endoscopy International Open N2 - The growing number of publications on the application of artificial intelligence (AI) in medicine underlines the enormous importance and potential of this emerging field of research. In gastrointestinal endoscopy, AI has been applied to all segments of the gastrointestinal tract most importantly in the detection and characterization of colorectal polyps. However, AI research has been published also in the stomach and esophagus for both neoplastic and non-neoplastic disorders. The various technical as well as medical aspects of AI, however, remain confusing especially for non-expert physicians. This physician-engineer co-authored review explains the basic technical aspects of AI and provides a comprehensive overview of recent publications on AI in gastrointestinal endoscopy. Finally, a basic insight is offered into understanding publications on AI in gastrointestinal endoscopy. KW - Diagnose KW - Maschinelles Lernen KW - Gastroenterologie KW - Künstliche Intelligenz KW - Barrett's esophagus KW - Deep learning Y1 - 2019 U6 - https://doi.org/10.1055/a-1010-5705 VL - 07 IS - 12 SP - 1616 EP - 1623 PB - Georg Thieme Verlag CY - Stuttgart ER - TY - CHAP A1 - Wöhl, Rebecca A1 - Huber, Michaela A1 - Loibl, Markus A1 - Riebschläger, Birgit A1 - Nerlich, Michael A1 - Palm, Christoph T1 - The Impact of Semi-Automated Segmentation and 3D Analysis on Testing New Osteosynthesis Material T2 - Bildverarbeitung für die Medizin 2017; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 12. bis 14. März 2017 in Heidelberg N2 - A new protocol for testing osteosynthesis material postoperatively combining semi-automated segmentation and 3D analysis of surface meshes is proposed. By various steps of transformation and measuring, objective data can be collected. In this study the specifications of a locking plate used for mediocarpal arthrodesis of the wrist were examined. The results show, that union of the lunate, triquetrum, hamate and capitate was achieved and that the plate is comparable to coexisting arthrodesis systems. Additionally, it was shown, that the complications detected correlate to the clinical outcome. In synopsis, this protocol is considered beneficial and should be taken into account in further studies. KW - Osteosynthese KW - Implantatwerkstoff KW - Materialprüfung KW - Bildsegmentierung KW - Dreidimensionale Bildverarbeitung Y1 - 2017 U6 - https://doi.org/10.1007/978-3-662-54345-0_30 SP - 122 EP - 127 PB - Springer CY - Berlin ER - TY - CHAP A1 - Palm, Christoph T1 - Fusion of Serial 2D Section Images and MRI Reference BT - an Overview T2 - Workshop Innovative Verarbeitung bioelektrischer und biomagnetischer Signale (bbs2014), Berlin, 10.04.2014 N2 - Serial 2D section images with high resolution, resulting from innovative imaging methods become even more valuable, if they are fused with in vivo volumes. Achieving this goal, the 3D context of the sections would be restored, the deformations would be corrected and the artefacts would be eliminated. However, the registration in this field faces big challenges and is not solved in general. On the other hand, several approaches have been introduced dealing at least with some of these difficulties. Here, a brief overview of the topic is given and some of the solutions are presented. It does not constitute the claim to be a complete review, but could be a starting point for those who are interested in this field. KW - Kernspintomografie KW - Optimierung KW - Magnetic Resonance Imaging KW - MRI KW - Literaturbericht Y1 - 2014 U6 - https://doi.org/10.13140/RG.2.1.1358.3449 ER - TY - GEN A1 - Ebigbo, Alanna A1 - Rauber, David A1 - Ayoub, Mousa A1 - Birzle, Lisa A1 - Matsumura, Tomoaki A1 - Probst, Andreas A1 - Steinbrück, Ingo A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Meinikheim, Michael A1 - Scheppach, Markus W. A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Early Esophageal Cancer and the Generalizability of Artificial Intelligence T2 - Endoscopy N2 - Aims Artificial Intelligence (AI) systems in gastrointestinal endoscopy are narrow because they are trained to solve only one specific task. Unlike Narrow-AI, general AI systems may be able to solve multiple and unrelated tasks. We aimed to understand whether an AI system trained to detect, characterize, and segment early Barrett’s neoplasia (Barrett’s AI) is only capable of detecting this pathology or can also detect and segment other diseases like early squamous cell cancer (SCC). Methods 120 white light (WL) and narrow-band endoscopic images (NBI) from 60 patients (1 WL and 1 NBI image per patient) were extracted from the endoscopic database of the University Hospital Augsburg. Images were annotated by three expert endoscopists with extensive experience in the diagnosis and endoscopic resection of early esophageal neoplasias. An AI system based on DeepLabV3+architecture dedicated to early Barrett’s neoplasia was tested on these images. The AI system was neither trained with SCC images nor had it seen the test images prior to evaluation. The overlap between the three expert annotations („expert-agreement“) was the ground truth for evaluating AI performance. Results Barrett’s AI detected early SCC with a mean intersection over reference (IoR) of 92% when at least 1 pixel of the AI prediction overlapped with the expert-agreement. When the threshold was increased to 5%, 10%, and 20% overlap with the expert-agreement, the IoR was 88%, 85% and 82%, respectively. The mean Intersection Over Union (IoU) – a metric according to segmentation quality between the AI prediction and the expert-agreement – was 0.45. The mean expert IoU as a measure of agreement between the three experts was 0.60. Conclusions In the context of this pilot study, the predictions of SCC by a Barrett’s dedicated AI showed some overlap to the expert-agreement. Therefore, features learned from Barrett’s cancer-related training might be helpful also for SCC prediction. Our results allow different possible explanations. On the one hand, some Barrett’s cancer features generalize toward the related task of assessing early SCC. On the other hand, the Barrett’s AI is less specific to Barrett’s cancer than a general predictor of pathological tissue. However, we expect to enhance the detection quality significantly by extending the training to SCC-specific data. The insight of this study opens the way towards a transfer learning approach for more efficient training of AI to solve tasks in other domains. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1783775 VL - 56 IS - S 02 SP - S428 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Scheppach, Markus W. A1 - Mendel, Robert A1 - Rauber, David A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Meinikheim, Michael A1 - Palm, Christoph A1 - Messmann, Helmut A1 - Ebigbo, Alanna T1 - Artificial Intelligence (AI) improves endoscopists’ vessel detection during endoscopic submucosal dissection (ESD) T2 - Endoscopy N2 - Aims While AI has been successfully implemented in detecting and characterizing colonic polyps, its role in therapeutic endoscopy remains to be elucidated. Especially third space endoscopy procedures like ESD and peroral endoscopic myotomy (POEM) pose a technical challenge and the risk of operator-dependent complications like intraprocedural bleeding and perforation. Therefore, we aimed at developing an AI-algorithm for intraprocedural real time vessel detection during ESD and POEM. Methods A training dataset consisting of 5470 annotated still images from 59 full-length videos (47 ESD, 12 POEM) and 179681 unlabeled images was used to train a DeepLabV3+neural network with the ECMT semi-supervised learning method. Evaluation for vessel detection rate (VDR) and time (VDT) of 19 endoscopists with and without AI-support was performed using a testing dataset of 101 standardized video clips with 200 predefined blood vessels. Endoscopists were stratified into trainees and experts in third space endoscopy. Results The AI algorithm had a mean VDR of 93.5% and a median VDT of 0.32 seconds. AI support was associated with a statistically significant increase in VDR from 54.9% to 73.0% and from 59.0% to 74.1% for trainees and experts, respectively. VDT significantly decreased from 7.21 sec to 5.09 sec for trainees and from 6.10 sec to 5.38 sec for experts in the AI-support group. False positive (FP) readings occurred in 4.5% of frames. FP structures were detected significantly shorter than true positives (0.71 sec vs. 5.99 sec). Conclusions AI improved VDR and VDT of trainees and experts in third space endoscopy and may reduce performance variability during training. Further research is needed to evaluate the clinical impact of this new technology. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1782891 VL - 56 IS - S 02 SP - S93 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Zellmer, Stephan A1 - Rauber, David A1 - Probst, Andreas A1 - Weber, Tobias A1 - Braun, Georg A1 - Römmele, Christoph A1 - Nagl, Sandra A1 - Schnoy, Elisabeth A1 - Messmann, Helmut A1 - Ebigbo, Alanna A1 - Palm, Christoph T1 - Artificial intelligence as a tool in the detection of the papillary ostium during ERCP T2 - Endoscopy N2 - Aims Endoscopic retrograde cholangiopancreaticography (ERCP) is the gold standard in the diagnosis as well as treatment of diseases of the pancreatobiliary tract. However, it is technically complex and has a relatively high complication rate. In particular, cannulation of the papillary ostium remains challenging. The aim of this study is to examine whether a deep-learning algorithm can be used to detect the major duodenal papilla and in particular the papillary ostium reliably and could therefore be a valuable tool for inexperienced endoscopists, particularly in training situation. Methods We analyzed a total of 654 retrospectively collected images of 85 patients. Both the major duodenal papilla and the ostium were then segmented. Afterwards, a neural network was trained using a deep-learning algorithm. A 5-fold cross-validation was performed. Subsequently, we ran the algorithm on 5 prospectively collected videos of ERCPs. Results 5-fold cross-validation on the 654 labeled data resulted in an F1 value of 0.8007, a sensitivity of 0.8409 and a specificity of 0.9757 for the class papilla, and an F1 value of 0.5724, a sensitivity of 0.5456 and a specificity of 0.9966 for the class ostium. Regardless of the class, the average F1 value (class papilla and class ostium) was 0.6866, the sensitivity 0.6933 and the specificity 0.9861. In 100% of cases the AI-detected localization of the papillary ostium in the prospectively collected videos corresponded to the localization of the cannulation performed by the endoscopist. Conclusions In the present study, the neural network was able to identify the major duodenal papilla with a high sensitivity and high specificity. In detecting the papillary ostium, the sensitivity was notably lower. However, when used on videos, the AI was able to identify the location of the subsequent cannulation with 100% accuracy. In the future, the neural network will be trained with more data. Thus, a suitable tool for ERCP could be established, especially in the training situation. Y1 - 2024 U6 - https://doi.org/10.1055/s-0044-1783138 VL - 56 IS - S 02 SP - S198 PB - Thieme CY - Stuttgart ER -