TY - CHAP A1 - Maiwald, Frederik ED - Mottok, Jürgen ED - Reichenberger, Marcus ED - Bogner, Werner T1 - Simulation of Pyrometer Based Temperature Measurement Systems using Non-Sequential Raytracing T2 - Applied Research Conference 2018, ARC 2018, 10 July 2018, Deggendorf Y1 - 2018 SP - 168 EP - 171 PB - pro Business GmbH CY - Berlin ER - TY - CHAP A1 - Quandt, Benjamin ED - Mottok, Jürgen ED - Reichenberger, Marcus ED - Bogner, Werner T1 - Effect of the Detection Spot Size on pyrometric Temperature Signal at quasi-simultaneous Laser Transmission Welding T2 - Applied Research Conference 2018, ARC 2018, 10 July 2018, Deggendorf Y1 - 2018 SP - 261 EP - 264 PB - pro Business GmbH CY - Berlin ER - TY - JOUR A1 - van der Weerd, Bastiaan A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Trends in Electrochemical Sensing of Blood Gases JF - Bioanalytical Reviews N2 - The monitoring of partial pressures of the blood gases carbon dioxide (pCO2) and oxygen (pO2) is of great importance in clinical diagnostics. The measure of pCO2 and pO2 provides essential information about the patient’s metabolism, gas exchange, ventilation, and acid–base homeostasis. The conventional electrochemical methods for clinical blood gas analysis are based on the potentiometric Severinghaus sensor for carbon dioxide and the amperometric Clark sensor for oxygen. These techniques are well established and are only shortly discussed in this overview. However, in recent years a variety of modifications of these classical sensor concepts and new approaches of electrochemical sensing of pCO2 and pO2 have been introduced. This review summarizes recent developments in this field and discusses the potential for future applications in clinical blood gas analysis. KW - Blood gas analysis KW - Noninvasive blood gas sensor KW - Electrochemical sensor KW - Clinical analysis Y1 - 2016 U6 - https://doi.org/10.1007/11663_2016_1 VL - 6 SP - 263 EP - 280 PB - Springer CY - Berlin ER - TY - CHAP A1 - Raab, Peter A1 - Racek, Stanislav A1 - Krämer, Stefan A1 - Mottok, Jürgen T1 - Reliability of Task Execution during Safe Software Processing T2 - 15th Euromicro Conference on Digital System Design, Cesme, Turkey N2 - This paper presents the reliability evaluation of task execution during safe software processing. The standard method of duplication in a safety-critical application can also be applied for tasks in a software system. But in addition to this, there is also the possibility for coded task processing to increase the reliability and availability of software. The presented analysis covers the reliability analysis of a single, a duplicated and a coded task by the technique of continuous time Markov processes. Markov processes are often used for the reliability evaluation of safety-critical systems. We introduce a method to describe the execution time of tasks by means of enhanced Markov models and their solution by numerical methods. KW - reliability analysis KW - continuous-time Markov process KW - error probability KW - Erlang-distribution Y1 - 2012 U6 - https://doi.org/10.1109/DSD.2012.110 SP - 84 EP - 89 ER - TY - GEN A1 - Rück, Thomas A1 - Matysik, Frank-Michael A1 - Bierl, Rudolf T1 - Comparison of acoustic detectors for use in miniaturized photoacoustic devices designed for nitrogen dioxide trace gas measurement T2 - ANAKON, 23.-26.3.2015, Graz Y1 - 2015 ER - TY - CHAP A1 - Schumm, Michael A1 - Joseph, Saskia A1 - Schroll-Decker, Irmgard A1 - Niemetz, Michael A1 - Mottok, Jürgen T1 - Required competences in software engineering – pair programming as an instrument for facilitating life-long learning T2 - 15th International Conference on Interactive Collaborative Learning and 41st International Conference on Engineering Pedagogy, Villach N2 - The professional requirements in software engineering have become highly volatile due to the complexities of project development and rapid and innovative changes occurring in the field. Therefore, the development of inter-personal and social competences has gained central importance in the training of software developers. The following text will present a concept allowing to acquire competences by using Pair Programming as an instrument. Moreover, arrangements for learning and teaching will be presented facilitating the acquisition of these competences. By approaching the issue of competence acquisition on a technical as well as on an educational and social level, lifelong learning is facilitated and supported. Y1 - 2012 U6 - https://doi.org/10.1109/ICL.2012.6402229 ER - TY - GEN A1 - Weigl, Stefan A1 - Matysik, Frank-Michael A1 - Bierl, Rudolf T1 - Development of a sensor system for analysis of human breath exhale T2 - BayWISS Herbstakademie 2018, Plankstetten N2 - Atemgasanalyse ist ein junges und vielversprechendes Feld im Bereich der diagnostischen Medizin. Der Ansatz verspricht einfach zugängliche und leicht wiederholbare Probennahme die zum einen non-invasiv ist und zugleich Rückschlüsse auf Vorgänge im menschlichen Körper und bspw. dessen Gesundheitszustand zulässt. Seit Ende des 20. Jahrhunderts gibt es Massenspektrometer die es ermöglicht haben mehrere Tausend verschiedene Stoffe in der Ausatemluft nachzuweisen. Diese Technologien verbessern sich stetig und ermöglichen es die Vorgänge und Zusammenhänge zwischen Zusammensetzung der Ausatemluft und systemischen Prozessen besser zu verstehen. Die bei Studien mit Massenspektrometern ermittelten Biomarker, deren qualitative und quantitative Detektion Gesundheitsdiagnosen ermöglichen, haben aber noch nicht den Weg in den klinischen Alltag gefunden. Das Problem sind meistens die hohen Anschaffungskosten, komplizierte Datenauswertung und zumeist geringe Verfügbarkeit und Immobilität dieser Messgeräte. Die photoakustische Spektroskopie ist eine selektive und hochsensitive Messmethode, die es ermöglichen soll den Biomarker „Aceton“, der grundsätzlich die Metabolisierung von Fetten widerspiegelt, schnell und reproduzierbar quantitativ zu detektieren. Dabei müssen Hindernisse wie Querempfindlichkeiten, ausgelöst durch die komplexe Zusammensetzung der Messmatrix Atemgas, bei gleichzeitig kleine Aceton Konzentrationen (200-800 parts-per-billion) überwunden werden. Verschiedene Wellenlängenbereiche mit unterschiedlichen Lichtquellen, akustisch resonante sowie innovative Messzellendesigns und anspruchsvolle Datenauswertung mittels komplexer Algorithmik sind nötig um das Ziel, die Entwicklung eines kompakten, günstigen und zuverlässigen Acetonsensors, zu erreichen. Y1 - 2018 ER - TY - JOUR A1 - Rück, Thomas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Low-cost photoacoustic NO2 trace gas monitoring at the pptV-level JF - Sensors and Actuators A: Physical N2 - We present the development and the characterization of a photoacoustic NO2 trace gas detection system. The system is based on the implementation of low-cost components, i.e. a mass-produced blue diode laser and a standard MEMS microphone which is commonly built into smartphones, for example. An optimized cell design was realized by means of 3D printing. The linearity of the photoacoustic signal dependency on the analyte concentration was verified from 200 ppbV to 100 ppmV NO2. The detection limit (1σ) was determined to 33 pptV and the normalized noise equivalent absorption coefficient was calculated to 7.0 ∙ 10−10 W cm−1 Hz−1/2. The dynamic range of the system was verified to be linear over three magnitudes of order and the sensitivity was calculated to 814 μV/ppmV. The system was characterized in view of optimal operating parameters, i.e. lock-in time constant τLIA and total mass flow rate, optical performance and signal stability. The mass flow dependend response time of the system was specified to 19 s and an idealized step response to a quasi-Heaviside step function was quantified as a function of τLIA. The quality factor of acoustic resonance was determined to 21.9 and an empirical expression regarding acoustic node shifting is provided. The expression takes into account the radius of the resonator pipe and the radius of the hole, which was drilled into the pipe for microphone coupling. Furthermore, we studied the cross-sensitivity of the photoacoustic signal towards H2O and CO2, respectively. Y1 - 2017 U6 - https://doi.org/10.1016/j.sna.2017.06.036 VL - 263 SP - 501 EP - 509 PB - Elsevier CY - Amsterdam, Niederlande ER - TY - JOUR A1 - Rück, Thomas A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - NO2 trace gas monitoring in air using off-beam quartz enhanced photoacoustic spectroscopy (QEPAS) and interference studies towards CO2, H2O and acoustic noise JF - Sensors and Actuators B: Chemical N2 - We present the development and characterization as well as comprehensive interference studies of a photoacoustic NO2 trace gas detection system. The system is based on an off-beam quartz enhanced photoacoustic scheme (off-beam QEPAS) and signal generation was initiated by amplitude modulating a low-cost diode laser emitting at 450 nm. The QEPAS sensor element features double-resonant amplification, still it is only ∼ 5 × 5 × 2.5 mm in size. The individual and combined resonance characteristics were investigated and specified to 52 dB amplification, adding up 15 dB acoustic- and 37 dB mechanical-resonance amplification. The linearity of the photoacoustic signal dependency on the analyte concentration was verified from 200 ppbV to 100 ppmV NO2 in synthetic air. The detection limit (3σ) was determined to 1.8 ppbV using a lock-in time constant of 10 s and an averaging time of 20 s. The normalized noise equivalent absorption coefficient was specified to 2.5·10−8 W cm−1 Hz−0.5. The stability of the signal was investigated over time and a slight drift by 1‰ was observed after 30 min without temperature stabilizing the photoacoustic cell (PAC). Noise analysis was performed by means of Allan deviation and the inverse dependency of response time and precision of the system on the lock-in time constant was outlined. We performed interference analyses towards N2, O2, CO2, H2O and acoustic noise, respectively. Although neither spectral interferences nor losses due to slow NO2 VT-relaxation were observed, O2 was identified to cause a 15% signal drop due to VVNO2-O2-relaxation. Changing H2O concentrations were found to cause acoustic detuning, which cannot be compensated by adjusting the frequency of modulation, because of the double-resonant feature of the PAC. However, alternative approaches of compensation were discussed. Finally, we carried out heavy traffic noise simulations and determined the QEPAS setup to be 46 times less susceptible towards ambient noise compared to standard microphone-based photoacoustic setups. Y1 - 2018 U6 - https://doi.org/10.1016/j.snb.2017.09.039 VL - 255 IS - Part 3, February SP - 2462 EP - 2471 PB - Elsevier ER - TY - CHAP A1 - Hausler, Peter A1 - Wunderlich, Lukas A1 - Fischer, Johannes A1 - Pfab, Christina A1 - Heckscher, Simon A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Surface plasmon resonance imaging for detection of drug metabolites in water T2 - Proceedings of SPIE, Optical Sensors 2019, 1 - 4 April 2019, Prague, Czech Republic N2 - The analysis of surface water, groundwater, drinking water as well as sewage is important to get information about the contamination of the water cycle. Currently, these time-consuming investigations require special equipment, like for example hyphenated mass spectrometry. Surface plasmon resonance (SPR) is a faster alternative as it is highly sensitive to changes in the dielectric medium next to a thin metal layer and makes it a quasi-universal detector. Therefore, and due to the labelfree nature, SPR is a widely used sensing tool for real‐time monitoring of molecular interactions of various analytes. SPR imaging (SPRi) has several advantages to standard surface plasmon resonance, as it allows to observe many analytes in parallel as well as the integration of referencing technologies. However, the homogenous illumination of a large area (several millimeters) with a small light source is challenging and demands new approaches. Allopurinol, a drug used to lower the blood concentration of urate and hence decrease the affection of gout, gets metabolized to oxipurinol in the body and dropped out almost entirely by urinary excretion. After wastewater treatment, concentrations of oxipurinol up to 21.7 μg•L-1 are detected. Further tracking of oxipurinol in the urban water cycle showed its presence in rivers and streams or even in groundwater. Therefore, the high biological stability of oxipurinol allows this molecule to be used as a marker for domestic wastewater in the environment. For the detection of oxipurinol by SPR graphene was used as receptive layer, as the analyte can bind via π-stacking to this surface. An SPRi technique was developed and compared to conventional SPR system for the detection of oxipurinol. Y1 - 2019 U6 - https://doi.org/10.1117/12.2522324 SN - 0277-786X VL - Vol. 11028 ER - TY - JOUR A1 - Weigl, Stefan A1 - Feldmeier, Florian A1 - Bierl, Rudolf A1 - Matysik, Frank-Michael T1 - Photoacoustic detection of acetone in N2 and synthetic air using a high power UV LED JF - Sensors Actuators B Chemical N2 - The performance of a photoacoustic trace gas sensor for the detection of acetone in N2 and synthetic air is reported. The sensor system utilises an amplitude modulated UV LED. The light source has an emission maximum at 278 nm and a maximum CW output power of 300 mW according to the datasheet. Three different collimating and focusing approaches have been investigated to guide the highly divergent LED light into the acoustic resonator of the photoacoustic measurement cell. A 3D printed aluminium cell was designed to optimize light coupling by simultaneously minimizing the photoacoustic background signal generation. Hence, the diameter of the resonator was set to a comparable large diameter of 10 mm and the inner walls of the resonator were mirror polished. The additive manufacturing procedure allowed for integration of a spirally formed gas channel, enabling gas heating prior to detection. The sensor performance was investigated by measuring acetone in N2 and synthetic air at different concentrations. The UV LED current was set to 86 % of the maximum value according to the datasheet of the light source in order to increase the lifetime and thermal stability. An Allan-Werle deviation analysis validates a stable sensor performance. The limit of detection (LoD) was determined at a 3σ noise level with a 10 s lock-in amplifier time constant by sampling data points over 20 s with a data acquisition rate of 5 Hz. LoDs of 80.8 ppbV and 19.6 ppbV were obtained for acetone in N2 and synthetic air, respectively. KW - Acetone detection KW - Photoacoustic spectroscopy KW - High power UV LED KW - UV LED collimation system KW - Acetone breath analysis Y1 - 2020 U6 - https://doi.org/10.1016/j.snb.2020.128109 N1 - Corresponding author at: Sensorik-Applikationszentrum (SappZ) der Ostbayerischen Technischen Hochschule Regensburg VL - 316 IS - August SP - 1 EP - 11 PB - Elsevier ER - TY - CHAP A1 - Hausler, Peter A1 - Genslein, Christa A1 - Roth, Carina A1 - Vitzthumecker, Thomas A1 - Hirsch, Thomas A1 - Bierl, Rudolf T1 - Miniaturized Surface Plasmon Resonance based Sensor System T2 - Proceedings of the 6th International Conference on Photonics, Optics and Laser Technology - PHOTOPTICS, Funchal, Madeira, Portugal N2 - We describe the miniaturization of the Surface Plasmon Resonance (SPR) technology which mainly finds its applications in pharmaceutical screening and biotechnology so far. SPR spectroscopy is a label-free, non-destructive and highly sensitive measurement principle detecting changes in the refractive index in striking distance to a gold surface. A transfer of this technology to a miniaturized sensor will broaden the range of possible applications. A promising feature which is included in the miniaturized system is the angle-dependent recording of the SPR signals without moving parts. Commercial SPR assays are mainly working with a small number of sensing spots. In contrast, the SPR imaging system shown here will allow to use an array of many sensing spots. In combination with chemical receptors designed as an artificial nose, the simultaneous detection of many analytes is envisioned for future applications. KW - Surface Plasmon Resonance Spectroscopy KW - Sensor KW - SPR-imaging KW - Miniaturization KW - Micro-Opto-Electro-Mechanical Systems Y1 - 2018 SN - 978-989-758-286-8 U6 - https://doi.org/10.5220/0006555400630066 SP - 63 EP - 66 PB - SciTePress ER - TY - JOUR A1 - Bieker, Johannes A1 - Roustaie, Farough A1 - Schlaak, Helmut F. A1 - Langer, Christoph A1 - Schreiner, Rupert A1 - Lotz, Marcel A1 - Wilfert, Stefan T1 - Field emission characterization of in situ deposited gold nanocones with variable cone densities JF - Journal of Vacuum Science and Technology B N2 - For the fabrication of field emitter cathodes with metallic nanocones, an in situ fabrication technique based on electrodeposition in an ion track etched polymer template was used. Three samples with nanocones made of gold and different cone densities were deposited on a circular electrode with a diameter of 2.5 mm, using templates with pore density of 6 × 104, 4 × 105, and 1 × 106 cones/cm2. The cones had a height of 24 μm, a base diameter between 3 and 3.75 μm, and a tip diameter below 500 nm. Integral field emission measurements revealed onset fields of down to 3.1 V/μm and average field enhancement factors of up to 1240. For one sample, the maximum emission current from the cathode reached 142.2 μA at an applied voltage of 338 V between cathode and extraction grid, which had a distance of 50 μm. To investigate the stability of the field emission current, cumulative long-term measurements were performed for over 50 h. A stable emission current of (31.0 ± 1.3) μA at an average applied voltage of 290 V (E = 5.8 V/μm) was observed. For currents above 100 μA, a decrease of the current and therefore a degradation of the emitter structures occurred. Y1 - 2018 U6 - https://doi.org/10.1116/1.5009504 VL - 36 IS - 2 PB - AIP Publishing ER - TY - CHAP A1 - Mottok, Jürgen T1 - Embedded trends T2 - Technologietag 2012, am 28. März, München Y1 - 2012 ER -