TY - CHAP A1 - Schaeffer, Leon A1 - Schmaußer, Theresa A1 - Herrmann, David A1 - Lehmann, Lukas A1 - Dendorfer, Sebastian A1 - Böhm, Valter T1 - Multi-Body Simulation of a Dynamic Hand Orthosis based on a Prestressed Compliant Structure Incorporating the Human Hand T2 - 2025 International Symposium on Medical Robotics (ISMR), May 14-16, 2025, Atlanta, GA, USA, N2 - Many dynamic hand orthoses use one degree of freedom joints, such as hinge joints. Therefore, these orthoses can only partially replicate the complex, multi-axis movement of the hand. A possible solution for this is the use of prestressed compliant structures as the basis for orthoses. Determining the joint forces in the wrist and optimizing the dynamic orthosis to influence these forces as well as acting muscle forces are important steps in the development of these orthoses. For this reason, in this work multi-body simulation models of an orthosis with human hand models are presented. Based on these theoretical investigations, more detailed orthosis models as well as initial prototypes of prestressed compliant dynamic hand orthoses can be developed. KW - Hands KW - Wrist KW - Systematics KW - Simulation KW - Dynamics KW - Refining KW - Prototypes KW - Usability KW - Research and development KW - Testing Y1 - 2025 U6 - https://doi.org/10.1109/ISMR67322.2025.11025982 SP - 80 EP - 86 PB - IEEE ER - TY - JOUR A1 - Geith, Markus A. A1 - Swidergal, Krzysztof A1 - Hochholdinger, Bernd A1 - Schratzenstaller, Thomas A1 - Wagner, Marcus A1 - Holzapfel, Gerhard A. T1 - On the importance of modeling balloon folding, pleating, and stent crimping: An FE study comparing experimental inflation tests JF - International Journal for Numerical Methods in Biomedical Engineering N2 - Finite element (FE)–based studies of preoperative processes such as folding,pleating, and stent crimping with a comparison with experimental inflation tests are not yet available. Therefore, a novel workflow is presented in which residual stresses of balloon folding and pleating, as well as stent crimping, and the geometries of all contact partners were ultimately implemented in an FE code to simulate stent expansion by using an implicit solver. The numerical results demonstrate that the incorporation of residual stresses and strains experienced during the production step significantly increased the accuracy of the subsequent simulations, especially of the stent expansion model. During the preoperative processes, stresses inside the membrane and the stent material also reached a rather high level. Hence, there can be no presumption that balloon catheters or stents are undamaged before the actual surgery. The implementation of the realistic geometry, in particular the balloon tapers, and the blades of the process devices improved the simulation of the expansion mech-anisms, such as dogboning, concave bending, or overexpansion of stent cells. This study shows that implicit solvers are able to precisely simulate the mentioned preoperative processes and the stent expansion procedure without a preceding manipulation of the simulation time or physical mass. KW - Catheter KW - Coronary KW - Crimping KW - Finite element KW - Stent KW - Stent KW - Implantation KW - Simulation KW - Finite-Elemente-Methode Y1 - 2019 U6 - https://doi.org/10.1002/cnm.3249 N1 - This study was funded by the Bavarian Research Foundation within the project “PIZ‐225‐18” VL - 35 IS - 11 PB - Wiley ER -