    <title language="eng">Gated p-Si field emission cathode applied in an ionization vacuum gauge</title>
    <abstract language="eng">A commercial Bayard-Alpert ionization vacuum gauge was equipped with a field emission electron source based on a cathode consisting of an array of 16 gated, p-doped, and DLC-coated Si-tips and characterized. An anode current of about 1.3 μA led to an ion current of 7 fA at 3×10 -7 mbar and 0.8 pA at 4×10 -5 mbar. Whereas at pressures higher than 4×10 -5 mbar the emission current of the electron source decreased, the ratio of ion and anode current remained linear. A nearly constant sensitivity of ~ 17 mbar -1 of the ionization vacuum gauge within the investigated pressure range was depicted.</abstract>
    <parentTitle language="eng">29th International Vacuum Nanoelectronics Conference (IVNC), 2016,  11-15 July, Vancouver, BC, Canada</parentTitle>
    <identifier type="issn">2380-6311</identifier>
    <identifier type="doi">10.1109/IVNC.2016.7551500</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <author>Christoph Langer</author>
    <author>Christian Prommesberger</author>
    <author>Robert Damian Ławrowski</author>
    <author>Rupert Schreiner</author>
    <author>Yifeng Huang</author>
    <author>Juncong She</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>field emission</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>field emitter array</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Si</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>DLC</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>electron source</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>ionization vacuum gauge</value>
    </subject>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlmconf">Schreiner, Rupert (Prof. Dr.), Konferenzbeiträge - Labor für Mikrosensorik</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="">Digitale Transformation</collection>
  </doc>
</export-example>