    <title language="eng">Design of a reverse shoulder implant to measure shoulder stiffness during implant component positioning</title>
    <abstract language="eng">To avoid dislocation of the shoulder joint after reverse total shoulder arthroplasty, it is important to achieve sufficient shoulder stability when placing the implant components during surgery. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this research was to develop a temporary reverse shoulder implant prototype that would allow intraoperative measurement of shoulder stiffness while varying the position of the implant components. Joint angle and torque measurement techniques were developed to determine shoulder stiffness. Hall sensors were used to measure the joint angles by converting the magnetic flux densities into angles. The accuracy of the joint angle measurements was tested using a test bench. Torques were determined by using thin-film pressure sensors. Various mechanical mechanisms for variable positioning of the implant components were integrated into the prototype. The results of the joint angle measurements showed measurement errors of less than 5° in a deflection range of ±15° adduction/abduction combined with ±45° flexion/extension. The proposed design provides a first approach for intra-operative assessment of shoulder stiffness. The findings can be used as a technological basis for further developments.</abstract>
    <parentTitle language="eng">Medical Engineering &amp; Physics</parentTitle>
    <identifier type="doi">10.1016/j.medengphy.2023.104059</identifier>
    <note>Corresponding author: Sebstian Dendorfer</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="CorrespondingAuthor">Sebstian Dendorfer</enrichment>
    <licence>Creative Commons - CC BY-NC-ND - Namensnennung - Nicht kommerziell - Keine Bearbeitungen 4.0 International</licence>
    <author>Nikolas Förstl</author>
    <author>Franz Süß</author>
    <author>Carsten Englert</author>
    <author>Sebastian Dendorfer</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">Publikationsfonds der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
</export-example>